Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cancer models”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Interstitial rotating shield brachytherapy for prostate cancer

Purpose: To present a novel needle, catheter, and radiation source system for interstitial rotating shield brachytherapy (I-RSBT) of the prostate. I-RSBT is a promising technique for reducing urethra, rectum, and bladder dose relative to conventional interstitial high-dose-rate brachytherapy (HDR-BT). Methods: A wire-mounted 62 GBq{sup 153}Gd source is proposed with an encapsulated diameter of 0.59 mm, active diameter of 0.44 mm, and active length of 10 mm. A concept model I-RSBT needle/catheter pair was constructed using concentric 50 and 75 μm thick nickel-titanium alloy (nitinol) tubes. The needle is 16-gauge (1.651 mm) in outer diameter and the catheter contains a 535 μm thick platinum shield. I-RSBT and conventional HDR-BT treatment plans for a prostate cancer patient were generated based on Monte Carlo dose calculations. In order to minimize urethral dose, urethral dose gradient volumes within 0–5 mm of the urethra surface were allowed to receive doses less than the prescribed dose of 100%. Results: The platinum shield reduced the dose rate on the shielded side of the source at 1 cm off-axis to 6.4% of the dose rate on the unshielded side. For the case considered, for the same minimum dose to the hottest 98% of the clinical target volume (D{sub 98%}), I-RSBT reduced urethral D{sub 0.1cc} below that of conventional HDR-BT by 29%, 33%, 38%, and 44% for urethral dose gradient volumes within 0, 1, 3, and 5 mm of the urethra surface, respectively. Percentages are expressed relative to the prescription dose of 100%. For the case considered, for the same urethral dose gradient volumes, rectum D{sub 1cc} was reduced by 7%, 6%, 6%, and 6%, respectively, and bladder D{sub 1cc} was reduced by 4%, 5%, 5%, and 6%, respectively. Treatment time to deliver 20 Gy with I-RSBT was 154 min with ten 62 GBq {sup 153}Gd sources. Conclusions: For the case considered, the proposed{sup 153}Gd-based I-RSBT system has the potential to lower the urethral dose relative to HDR-BT by 29%–44% if the clinician allows a urethral dose gradient volume of 0–5 mm around the urethra to receive a dose below the prescription. A multisource approach is necessary in order to deliver the proposed {sup 153}Gd-based I-RSBT technique in reasonable treatment times.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Failure Rates and Patterns of Recurrence in Patients With Resected N1 Non-Small-Cell Lung Cancer

Purpose: To examine the local and distant recurrence rates and patterns of failure in patients undergoing potentially curative resection of N1 non-small-cell lung cancer. Methods and Materials: The study included 60 consecutive unirradiated patients treated from 2000 to 2006. Median follow-up was 30 months. Failure rates were calculated by the Kaplan-Meier method. A univariate Cox proportional hazard model was used to assess factors associated with recurrence. Results: Local and distant failure rates (as the first site of failure) at 2, 3, and 5 years were 33%, 33%, and 46%; and 26%, 26%, and 32%, respectively. The most common site of local failure was in the mediastinum; 12 of 18 local recurrences would have been included within proposed postoperative radiotherapy fields. Patients who received chemotherapy were found to be at increased risk of local failure, whereas those who underwent pneumonectomy or who had more positive nodes had significantly increased risks of distant failure. Conclusions: Patients with resected non-small-cell lung cancer who have N1 disease are at substantial risk of local recurrence as the first site of relapse, which is greater than the risk of distant failure. The role of postoperative radiotherapy in such patients should be revisited in the era of adjuvant chemotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Influencing Outcome in Oropharynx Cancer With Intensity-Modulated Radiotherapy? An Inter-Era Comparison

Purpose: To analyze the outcome in all oropharynx cancer patients treated at University of Wisconsin during 1995-2005 and highlight the methodologic challenge in comparing outcome after intensity-modulated radiotherapy (IMRT) with that of historical controls. Methods and Materials: Outcomes were compared in 195 oropharynx cancer patients after definitive radiotherapy with curative intent in the pre-IMRT era (pre-IMRT, n = 105), after IMRT (IMRT+, n = 52) or after non-IMRT techniques during the IMRT era (IMRT-, n = 38). Results: With a median follow-up of 30.4 months, the 3-year overall survival rate in IMRT+, IMRT-, and pre-IMRT patients was 88.2%, 81.1%, and 67.7%, respectively; and for locoregional control was 96.1%, 78.1%, and 81.1%. Patients from the IMRT era more frequently received concurrent chemotherapy (67% vs. 6%, p < 0.001) and underwent adjuvant neck dissection (52% vs. 29%, p = 0.002). Patients with T3-4 disease and bilateral neck disease were significantly less likely to receive IMRT. Cox regression analysis identified IMRT as a significant prognostic factor (p = 0.04); however, after including T stage in the model, IMRT lost independent significance (p = 0.2). Analysis of a potential effect of IMRT on Grade 3+ mucositis or skin reaction was also hampered by the change in other treatment characteristics. Conclusions: Outcomes in oropharynx cancer have improved at our institution since the introduction of IMRT. However, multiple factors have contributed to this improvement, and presentation of IMRT outcomes without the full context of historical and contemporary controls may yield data that overstate outcome after IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced suppression of tumor growth by concomitant treatment of human lung cancer cells with suberoylanilide hydroxamic acid and arsenic trioxide

The efficacy of arsenic trioxide (ATO) against acute promyelocytic leukemia (APL) and relapsed APL has been well documented. ATO may cause DNA damage by generating reactive oxygen intermediates. Suberoylanilide hydroxamic acid (SAHA), a histone deacetylase inhibitor, modulates gene and protein expression via histone-dependent or -independent pathways that may result in chromatin decondensation, cell cycle arrest, differentiation, and apoptosis. We investigated whether ATO and SAHA act synergistically to enhance the death of cancer cells. Our current findings showed that combined treatment with ATO and SAHA resulted in enhanced suppression of non-small-cell lung carcinoma in vitro in H1299 cells and in vivo in a xenograft mouse model. Flow cytometric analysis of annexin V+ cells showed that apoptotic cell death was significantly enhanced after combined treatment with ATO and SAHA. At the doses used, ATO did not interfere with cell cycle progression, but SAHA induced p21 expression and led to G1 arrest. A Comet assay demonstrated that ATO, but not SAHA, induced DNA strand breaks in H1299 cells; however, co-treatment with SAHA significantly increased ATO-induced DNA damage. Moreover, SAHA enhanced acetylation of histone H3 and sensitized genomic DNA to DNase I digestion. Our results suggest that SAHA may cause chromatin relaxation and increase cellular susceptibility to ATO-induced DNA damage. Combined administration of SAHA and ATO may be an effective approach to the treatment of lung cancer. -- Highlights: Black-Right-Pointing-Pointer ATO and SAHA are therapeutic agents with different action modes. Black-Right-Pointing-Pointer Combination of ATO and SAHA synergistically inhibits tumor cell growth. Black-Right-Pointing-Pointer SAHA loosens chromatin structure resulting in increased sensitivity to DNase I. Black-Right-Pointing-Pointer ATO-induced DNA damage and apoptosis are enhanced by co-treatment with SAHA.

60 APPLIED LIFE SCIENCES↗

Suppression of Exosomal PD-L1 Induces Systemic Anti-tumor Immunity and Memory

PD-L1 on the surface of tumor cells binds its receptor PD-1 on effector T cells, thereby suppressing their activity. Antibody blockade of PD-L1 can activate an anti-tumor immune response leading to durable remissions in a subset of cancer patients. Here, we describe an alternative mechanism of PD-L1 activity involving its secretion in tumor-derived exosomes. Removal of exosomal PD-L1 inhibits tumor growth, even in models resistant to anti-PD-L1 antibodies. Exosomal PD-L1 from the tumor suppresses T cell activation in the draining lymph node. Systemically introduced exosomal PD-L1 rescues growth of tumors unable to secrete their own. Exposure to exosomal PD-L1-deficient tumor cells suppresses growth of wild-type tumor cells injected at a distant site, simultaneously or months later. Anti-PD-L1 antibodies work additively, not redundantly, with exosomal PD-L1 blockade to suppress tumor growth. Together, these findings show that exosomal PD-L1 represents an unexplored therapeutic target, which could overcome resistance to current antibody approaches.

Biochemistry & Molecular Biology↗

Mortality among US underground coal miners: A 23-year follow-up

The mortality experience over 22-24 years of 8,899 working coal miners initially medically examined in 1969-1971 at 31 U.S. coal mines was evaluated. A cohort life-table analysis was undertaken on underlying causes of death, and proportional hazards models were fitted to both underlying, and underlying and contributing causes of death. Elevated mortality from nonviolent causes, nonmalignant respiratory disease (NMRD), and accidents was observed, but lung cancer and stomach cancer mortality were not elevated. Smoking, pneumoconiosis, coal rank region, and cumulative coal mine dust exposure were all predictors of mortality from nonviolent causes and NMRD. Mortality from nonviolent causes and NMRD was related to dust exposure within the complete cohort and also for the never smoker subgroup. Dust exposure relative risks for mortality were similar for pneumoconiosis, NMRD, and chronic airways obstruction. The findings confirm and enlarge upon previous results showing that exposure to coal mine dust leads to increased mortality, even in the absence of smoking.

01 COAL, LIGNITE, AND PEAT↗

A Small Tolerance for Catheter Displacement in High-Dose Rate Prostate Brachytherapy is Necessary and Feasible

Purpose: We examined catheter displacement in patients treated with fractionated high-dose rate (HDR) brachytherapy boost for prostate cancer and the impact this had on tumor control probability (TCP). These data were used to make conclusions on an acceptable amount of displacement. Methods and Materials: The last 20 patients treated with HDR brachytherapy boost for prostate cancer at our center in 2007 were replanned using simulated interstitial catheter displacements of 3, 6, 9, and 12 mm with originally planned dwell times. The computer-modeled dose-volume histograms for the clinical target volumes were exported and used to calculate the TCP of plans with displaced needles relative to the original plan. Actual catheter displacements were also measured before and after manual adjustment in all patients treated in 2007. Results: In the 20 patients who were replanned for caudal catheter displacements of 3, 6, 9, and 12 mm, the median relative TCP was 0.998, 0.964, 0.797, and 0.265, respectively (p < 0.01 when all medians were compared). All patients replanned with a 3-mm displacement, compared with only 75% with a 6-mm displacement, had a relative TCP greater than 0.950. In the 91 patients treated in 2007, before adjustment, 82.3% of fractions had a displacement greater than 3 mm compared with 12.2% of fractions after adjustment. Conclusions: Catheter displacement in HDR brachytherapy significantly compromises the TCP. The tolerance for these movements should be small (<=3 mm). Correcting these displacements to within acceptable limits is feasible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Evaluation of Incorporating Patient Geometric Variations Into Adaptive Plan Optimization Through Probabilistic Treatment Planning in Head and Neck Cancers

Four-dimensional (4D) adaptive radiation therapy (ART) treatment planning is an alternative to the conventional margin-based treatment planning approach. In 4D ART, interfraction patient geometric variations, gathered from computed tomography (CT) or cone beam CT (CBCT) images acquired during the patient treatment course, are directly incorporated into the adaptive plan optimization using a probabilistic treatment planning method. The goal of the present planning study was to evaluate the dosimetric differences between 4D ART and conventional margin-based adaptive planning strategies for head and neck cancers. In addition, we examined whether the dose differences achieved with 4D ART would translate into clinically relevant toxicity reductions using the existing normal tissue complication probability (NTCP) models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Inflammation-driven colon neoplasmatogenesis in uPA-deficient mice is associated with an increased expression of Runx transcriptional regulators

Highlights: • Inflammation-induced cancer-prone uPA{sup -/-} mouse colon has increased Runx expression. • Immune cells and colonic preneoplastic epithelia are major cellular sources of Runx. • Runx1/2 in uPA{sup -/-} mouse preneoplastic colonic epithelia correlates with cancer risk. • Snai2, Bim and Claudin1 are overexpressed in uPA{sup -/-} mouse proneoplastic colitis. Deregulation of the bone morphogenetic protein (BMP) pathway has been documented in colorectal cancer (CRC). Previously, we investigated possible associations between urokinase-type plasminogen activator (uPA) deficiency and expression of extracellular constituents of BMP signaling in a newly developed mouse model of inflammation-driven intestinal neoplasmatogenesis, in which chronic colitis and CRC are induced using dextran sodium sulfate (DSS). In this report, we explored the contribution of intracellular components of Smad-mediated BMP signal transduction using the same model. Interestingly, upon DSS treatment, we noticed an overexpression of Runx1/2/3 transcription factors in both wild-type and uPA-deficient mice. Moreover, Runx1 and Runx2 expression levels exhibited an even higher increase in DSS-treated/uPA-deficient mice as compared to DSS-treated/wild-type animals. In all experimental conditions, in situ investigation of Runx-expressing cell types, revealed detection of all three Runx in the immune cells, yet in the DSS-treated/uPA-deficient mice Runx1 and Runx2 were also identified in the preneoplastic epithelium of advanced high-grade dysplasia and carcinoma in-situ colonic lesions. Finally, the uPA-deficient pro-tumorigenic colitic microenvironment exhibited increased levels of the Runx-induced target genes Snai2, Bim and Claudin1, known to have a role in tumor development and progression. These findings suggest that the absence of uPA correlates with increased levels of Runx transcriptional regulators in a way that promotes inflammation-associated carcinogenesis.

60 APPLIED LIFE SCIENCES↗

Structural and Kinetic Analyses of Macrophage Migration Inhibitory Factor Active Site Interactions

Macrophage migration inhibitory factor (MIF) is a secreted protein expressed in numerous cell types that counters the antiinflammatory effects of glucocorticoids and has been implicated in sepsis, cancer, and certain autoimmune diseases. Interestingly, the structure of MIF contains a catalytic site resembling the tautomerase/isomerase sites of microbial enzymes. While bona fide physiological substrates remain unknown, model substrates have been identified. Selected compounds that bind in the tautomerase active site also inhibit biological functions of MIF. It had previously been shown that the acetaminophen metabolite, N-acetyl-p-benzoquinone imine (NAPQI), covalently binds to the active site of MIF. In this study, kinetic data indicate that NAPQI inhibits MIF both covalently and noncovalently. The structure of MIF cocrystallized with NAPQI reveals that the NAPQI has undergone a chemical alteration forming an acetaminophen dimer (bi-APAP) and binds noncovalently to MIF at the mouth of the active site. We also find that the commonly used protease inhibitor, phenylmethylsulfonyl fluoride (PMSF), forms a covalent complex with MIF and inhibits the tautomerase activity. Crystallographic analysis reveals the formation of a stable, novel covalent bond for PMSF between the catalytic nitrogen of the N-terminal proline and the sulfur of PMSF with complete, well-defined electron density in all three active sites of the MIF homotrimer. Conclusions are drawn from the structures of these two MIF-inhibitor complexes regarding the design of novel compounds that may provide more potent reversible and irreversible inhibition of MIF.

59 BASIC BIOLOGICAL SCIENCES↗

MO-FG-202-05: Identifying Treatment Planning System Errors in IROC-H Phantom Irradiations

Purpose: Treatment Planning System (TPS) errors can affect large numbers of cancer patients receiving radiation therapy. Using an independent recalculation system, the Imaging and Radiation Oncology Core-Houston (IROC-H) can identify institutions that have not sufficiently modelled their linear accelerators in their TPS model. Methods: Linear accelerator point measurement data from IROC-H’s site visits was aggregated and analyzed from over 30 linear accelerator models. Dosimetrically similar models were combined to create “classes”. The class data was used to construct customized beam models in an independent treatment dose verification system (TVS). Approximately 200 head and neck phantom plans from 2012 to 2015 were recalculated using this TVS. Comparison of plan accuracy was evaluated by comparing the measured dose to the institution’s TPS dose as well as the TVS dose. In cases where the TVS was more accurate than the institution by an average of >2%, the institution was identified as having a non-negligible TPS error. Results: Of the ∼200 recalculated plans, the average improvement using the TVS was ∼0.1%; i.e. the recalculation, on average, slightly outperformed the institution’s TPS. Of all the recalculated phantoms, 20% were identified as having a non-negligible TPS error. Fourteen plans failed current IROC-H criteria; the average TVS improvement of the failing plans was ∼3% and 57% were found to have non-negligible TPS errors. Conclusion: IROC-H has developed an independent recalculation system to identify institutions that have considerable TPS errors. A large number of institutions were found to have non-negligible TPS errors. Even institutions that passed IROC-H criteria could be identified as having a TPS error. Resolution of such errors would improve dose delivery for a large number of IROC-H phantoms and ultimately, patients.

60 APPLIED LIFE SCIENCES↗

False Indications of Dose-Response Nonlinearity in Large Epidemiologic Cancer Radiation Cohort Studies; A Simulation Exercise

This study explores the likely prevalence of false indications of dose-response nonlinearity in large epidemiologic cancer radiation cohort studies (A-bomb survivors, INWORKS, Techa River). Reasons: Increasing numbers of tests of nonlinearity are being made in studies. Hypothesized nonlinear dose-response models have been justified to policy makers by analyses that rely in part on isolated findings that could be statistical fluctuations. After removing dose nonlinearity (linearization) by adjusting person-years of observation at each dose category, indications of nonlinearity, necessarily false, were counted in 5,000 randomized replications of six datasets. The average frequency of any false positive for five indicators of nonlinearity tested against a linear null was roughly 25% in Monte Carlo simulations per study, consistent with binomial calculations, increasing to ~50% within 6 studies assessed. Comparable frequencies were found using Akaike's information criterion (AIC) for model selection or multi-model averaging. False above-zero threshold doses were found more than 50% of the time, averaging to 0.05 Gy, consistent with findings in the 6 studies. Such bias, uncorrected, could distort meta-analyses of multiple studies, because meta-analyses can incorporate high P value findings. AIC-based correction for the extra threshold parameter lowered these false occurrences to 8 to 19%. Given the simulation rates, the possibility of false positives might be noted when isolated findings of nonlinearity are discussed in a regulatory context. When reporting a threshold dose with a P value > 0.05, it would be informative to note the expected high false prevalence rate due to bias.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mitigation Strategies for Space Radiation Health Risks

Astronauts embarking on missions beyond low Earth orbit (LEO) will be exposed to a radiation field that may increase the risks of developing cancer, cardiovascular diseases, central nervous system disorders, and immune decrements. Operational parameters will be the primary determinants of crew radiation exposure. NASA uses integrated design tools and risk models to optimize these parameters to minimize radiation exposure. NASA is also considering medical countermeasures (MCMs) to reduce radiation-associated health risks. MCMs for potential use in space-based applications can be developed from a variety of sources, including: a) population-based chemoprevention trials against targeted diseases b) drug development efforts focused on treating acute effects from accidental radiation exposures c) drug development to mitigate side effects of radiotherapy d) mechanistic studies of distinct damage caused by high charge (Z) and energy (HZE) radiation. Use of agents developed for other applications, or repurposed, is advantageous because long-term safety in humans is already established.

Huff, Janice L.↗

Cis-Diammine(Pyridine)Chloroplatinum(II), a Monofunctional Platinum(II) Antitumor Agent: Uptake, Structure, Function, And Prospects

We have identified unique chemical and biological properties of a cationic monofunctional platinum(II) complex, cis-diammine(pyridine)chloroplatinum(II), cis-[Pt(NH{sub 3}){sub 2}(py)Cl]{sup +} or cDPCP, a coordination compound previously identified to have significant anticancer activity in a mouse tumor model. This compound is an excellent substrate for organic cation transporters 1 and 2, also designated SLC22A1 and SLC22A2, respectively. These transporters are abundantly expressed in human colorectal cancers, where they mediate uptake of oxaliplatin, cis-[Pt(DACH)(oxalate)] (DACH = trans-R,R-1,2-diaminocyclohexane), an FDA-approved first-line therapy for colorectal cancer. Unlike oxaliplatin, however, cDPCP binds DNA monofunctionally, as revealed by an x-ray crystal structure of cis-{l_brace}Pt(NH{sub 3}){sub 2}(py){r_brace}{sup 2+} bound to the N7 atom of a single guanosine residue in a DNA dodecamer duplex. Although the quaternary structure resembles that of B-form DNA, there is a base-pair step to the 5{prime} side of the Pt adduct with abnormally large shift and slide values, features characteristic of cisplatin intrastrand cross-links. cDPCP effectively blocks transcription from DNA templates carrying adducts of the complex, unlike DNA lesions of other monofunctional platinum(II) compounds like {l_brace}Pt(dien){r_brace}{sup 2+}. cDPCP-DNA adducts are removed by the nucleotide excision repair apparatus, albeit much less efficiently than bifunctional platinum-DNA intrastrand cross-links. These exceptional characteristics indicate that cDPCP and related complexes merit consideration as therapeutic options for treating colorectal and other cancers bearing appropriate cation transporters.

36 MATERIALS SCIENCE↗

Safety of Single-Site Laparoscopic Surgery Requiring Perioperative Heparinization in Colorectal Cancer: Propensity Score-Matched Analysis

Background: We assessed the feasibility and safety of single-site laparoscopic surgery for patients with colorectal cancer who required perioperative heparinization. Methods: This retrospective study reviewed the medical records of 390 patients who underwent single-site laparoscopic surgery for colorectal cancer from January 2010 to December 2016. Antithrombotic drugs were stopped preoperatively and heparin was administered according to the operative risk of each patient, based on consultation with the cardiologist physician or neurosurgeon. Propensity score modeling was utilized to adjust for baseline characteristics. Results: Of 390 patients, 29 were treated with standard bridging intravenous heparin therapy. Propensity matching identified 119 patients: 22 patients in the heparinization group and 97 in the control group. The matched groups were not significantly different in operation times, bleeding volumes, or conversion rate. The mean postoperative hospital stay was 17.9 days in the heparinization group and 9.5 days in the control group (p = 0.034). Postoperative bleeding was observed in 4 patients (18.2%) in the heparinization group and 11 patients (11.4%) in the control group (p = 0.646), while other complications were similar in the two study groups (p = 0.502). Of these other complications, thromboembolic events were observed in two patients in the heparinization group and one patient in the control group. Conclusions: We found that single-site laparoscopic surgery for colorectal cancer with heparinization was feasible and safe. Heparinization did not increase the risk of postoperative bleeding complications, but postoperative hospital stay was prolonged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sci-Fri PM: Radiation Therapy, Planning, Imaging, and Special Techniques - 03: The Potential Benefit Of Esophageal Sparing During Palliative Radiotherapy For Lung Cancer

Puropose: Palliative radiotherapy is an effective technique to alleviate systems of disease burden in late-stage lung cancer patients. Previous randomized controlled studies demonstrated a survival benefit in patients with good performance status at radiation doses of 35Gy10 or greater but with an increased incidence of esophagitis. The objective of this planning study was to assess the potential impact of esophageal-sparing IMRT (ES-IMRT) compared to the current standard of care using parallel-opposed pair beams (POP). Methods: In this study, 15 patients with lung cancer treated to a dose of 30Gy in 10 fractions between August 2015 and January 2016 were identified. Radiation treatment plans were optimized using ES-IMRT by limiting the max esophagus point dose to 24Gy. Using published Lyman-Kutcher-Burman normal tissue complication probabilities (LKB-NTCP) models, both plans were evaluated for the likelihood of esophagitis (≥ grade 2) and pneumonitis (≥ grade 2). Results: Using ES-IMRT, the median esophageal and lung mean doses reduced from 16 and 8Gy to 7 and 7Gy, respectively. Using the LKB models, the theoretical probability of symptomatic esophagitis and pneumonitis reduced from 13 to 1%, and from 5 to 3%, respectively. The median NTD mean for the GTV and PTV of the clinically approved POP plans compared to the ES-IMRT plans were similar. Conclusions: Advanced radiotherapy techniques such as ES-IMRT may have clinical utility in reducing treatment-related toxicity in advanced lung cancer patients. Our data suggests that the rate of esophagitis can be reduced without compromising tumour control.

60 APPLIED LIFE SCIENCES↗

The value of integrating pre-clinical data to predict nausea and vomiting risk in humans as illustrated by AZD3514, a novel androgen receptor modulator

Nausea and vomiting are components of a complex mechanism that signals food avoidance and protection of the body against the absorption of ingested toxins. This response can also be triggered by pharmaceuticals. Predicting clinical nausea and vomiting liability for pharmaceutical agents based on pre-clinical data can be problematic as no single animal model is a universal predictor. Moreover, efforts to improve models are hampered by the lack of translational animal and human data in the public domain. AZD3514 is a novel, orally-administered compound that inhibits androgen receptor signaling and down-regulates androgen receptor expression. Here we have explored the utility of integrating data from several pre-clinical models to predict nausea and vomiting in the clinic. Single and repeat doses of AZD3514 resulted in emesis, salivation and gastrointestinal disturbances in the dog, and inhibited gastric emptying in rats after a single dose. AZD3514, at clinically relevant exposures, induced dose-responsive “pica” behaviour in rats after single and multiple daily doses, and induced retching and vomiting behaviour in ferrets after a single dose. We compare these data with the clinical manifestation of nausea and vomiting encountered in patients with castration-resistant prostate cancer receiving AZD3514. Our data reveal a striking relationship between the pre-clinical observations described and the experience of nausea and vomiting in the clinic. In conclusion, the emetic nature of AZD3514 was predicted across a range of pre-clinical models, and the approach presented provides a valuable framework for predicition of clinical nausea and vomiting. - Highlights: • Integrated pre-clinical data can be used to predict clinical nausea and vomiting. • Data integrated from standard toxicology studies is sufficient to make a prediction. • The use of the nausea algorithm developed by Parkinson (2012) aids the prediction. • Additional pre-clinical studies can be used to confirm and quantify the risk.

60 APPLIED LIFE SCIENCES↗

Surface applicator calibration and commissioning of an electronic brachytherapy system for nonmelanoma skin cancer treatment

Purpose: The Xoft Axxent x-ray source has been used for treating nonmelanoma skin cancer since the surface applicators became clinically available in 2009. The authors report comprehensive calibration procedures for the electronic brachytherapy (eBx) system with the surface applicators. Methods: The Xoft miniature tube (model S700) generates 50 kVp low-energy x rays. The new surface applicators are available in four sizes of 10, 20, 35, and 50 mm in diameter. The authors' tests include measurements of dose rate, air-gap factor, output stability, depth dose verification, beam flatness and symmetry, and treatment planning with patient specific cutout factors. The TG-61 in-air method was used as a guideline for acquiring nominal dose-rate output at the skin surface. A soft x-ray parallel-plate chamber (PTW T34013) and electrometer was used for the output commissioning. GafChromic EBT films were used for testing the properties of the treatment fields with the skin applicators. Solid water slabs were used to verify the depth dose and cutout factors. Patients with basal cell or squamous cell carcinoma were treated with eBx using a calibrated Xoft system with the low-energy x-ray source and the skin applicators. Results: The average nominal dose-rate output at the skin surface for the 35 mm applicator is 1.35 Gy/min with {+-}5% variation for 16 sources. The dose-rate output and stability (within {+-}5% variation) were also measured for the remaining three applicators. For the same source, the output variation is within 2%. The effective source-surface distance was calculated based on the air-gap measurements for four applicator sizes. The field flatness and symmetry are well within 5%. Percentage depth dose in water was provided by factory measurements and can be verified using solid water slabs. Treatment duration was calculated based on the nominal dose rate, the prescription fraction size, the depth dose percentage, and the cutout factor. The output factor needs to be measured for each case with varying shapes of cutouts. Conclusions: Together with TG-61, the authors' methodology provides comprehensive calibration procedures for medical physicists for using the Xoft eBx system and skin applicators for nonmelanoma skin cancer treatments.

60 APPLIED LIFE SCIENCES↗