Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

The Orion OB1 association. 1: Stellar content

Walfraven photometry of established and probable members of the Orion OB1 association is presented. Effective temperature, surface gravity, luminosity and mass are derived for all stars, using atmosphere model by Kurucz (1979). Absolute magnitudes are calculated using the Straizys and Kuriliene (1981) tables. Distance moduli and visual extinctions are determined. A comparison of the visual extinctions to IRAS 100 micrometers data shows that the near edge of the Orion A and B clouds lies at a distance of approximately 320 pc, while the far edge is at approximately 500 pc. A method for deriving the ages of the subgroups by comparing theoretical isochrones to the observations in the log g, log T(sub eff) plane is presented. The derived ages suggest, contrary to earlier studies, that subgroup 1b is younger than 1c, which can possibly be explained by past geometries of the system of stars and gas. The initial mass function for Orion OB1 is derived with the aid of the Kolmogorov-Smirnoff test. Through extensive simulations, we show that it is very difficult to derive accurately the Initial Mass Function (IMF) from the available data. To within somewhat weak limits the IMF is found to be of the form xi(log M) = AM(exp -1.7 +/- 0.2) for all subgroups. The energy output of the subgroups in the form of stellar winds and supernovae is calculated and compared to the observed size and expansion velocity of the Orion-Eridanus bubble. It is shown that the energy output of the association can account for the morphology and kinematics of the interstellar medium (ISM).

Brown, A. G. A.↗

Developing New Coastal Forest Restoration Products Based on Landsat, ASTER, and MODIS Data

This paper discusses an ongoing effort to develop new geospatial information products for aiding coastal forest restoration and conservation efforts in coastal Louisiana and Mississippi. This project employs Landsat, Advanced Spaceborne Thermal Emission and Reflection Radiometer (ASTER), and Moderate Resolution Imaging Spectroradiometer (MODIS) satellite data in conjunction with airborne elevation data to compute coastal forest cover type maps and change detection products. Improved forest mapping products are needed to aid coastal forest restoration and management efforts of State and Federal agencies in the Northern Gulf of Mexico (NGOM) region. In particular, such products may aid coastal forest land acquisition and conservation easement procurements. This region's forests are often disturbed and subjected to multiple biotic and abiotic threats, including subsidence, salt water intrusion, hurricanes, sea-level rise, insect-induced defoliation and mortality, altered hydrology, wildfire, and conversion to non-forest land use. In some cases, such forest disturbance has led to forest loss or loss of regeneration capacity. In response, a case study was conducted to assess and demonstrate the potential of satellite remote sensing products for improving forest type maps and for assessing forest change over the last 25 years. Change detection products are needed for assessing risks for specific priority coastal forest types, such as live oak and baldcypress-dominated forest. Preliminary results indicate Landsat time series data are capable of generating the needed forest type and change detection products. Useful classifications were obtained using 2 strategies: 1) general forest classification based on use of 3 seasons of Landsat data from the same year; and 2) classification of specific forest types of concern using a single date of Landsat data in which a given targeted type is spectrally distinct compared to adjacent forested cover. When available, ASTER data was useful as a complement to Landsat data. Elevation data helped to define areas in which targeted forest types occur, such as live oak forests on natural levees. MODIS Normalized Difference Vegetation Index time series data aided visual assessments of coastal forest damage and recovery from hurricanes. Landsat change detection products enabled change to be identified at the stand level and at 10- year intervals with the earliest date preceding available change detection products from the National Oceanic and Atmospheric Administration and from the U.S. Geological Survey. Additional work is being done in collaboration with State and Federal agency partners in a follow-on NASA ROSES project to refine and validate these new, promising products. The products from the ROSES project will be available for aiding NGOM coastal forest restoration and conservation.

Spruce, Joseph P.↗

Discovery of Activities via Statistical Clustering of Fixation Patterns

Human behavior often consists of a series of distinct activities, each characterized by a unique signature of visual behavior. This is true even in a restricted domain, such as piloting an aircraft, where patterns of visual signatures might represent activities like communicating, navigating, and monitoring. We propose a novel analysis method for gaze-tracking data, to perform blind discovery of these activities based on their behavioral signatures. The method is in some respects similar to recurrence analysis, but here we compare not individual fixations, but groups of fixations aggregated over a fixed time interval. The duration of this interval is a parameter that we will refer to as τ. We assume that the environment has been divided into a set of N different areas-of-interest (AOIs). For a given interval of time of duration τ, we compute the proportion of time spent fixating each AOI, resulting in an N-dimensional vector. These proportions can be converted to counts by multiplying by τ divided by the average fixation duration (another parameter that we fix at 280 milliseconds). We compare different intervals by computing the chi-square statistic. The p-value associated with the statistic is the likelihood of observing the data under the hypothesis that the data in the two intervals were generated by a single process with a single set of probabilities governing the fixation of each AOI. We have investigated the method using a set of 10 synthetic "activities," that sample 4 AOIs. Four of these activities visit 3 of the 4 AOIs, with equal probability; as there are four different ways to leave-one- out, there are four such activities. Similarly, there are six different activities that leave-two-out. Sequences of simulated behavior were generated by running each activity for 40 seconds, in sequence, for a total of 6.7 minutes. The figure to the right shows the matrix of chi-square statistics, using a value of 2.8 seconds for τ, corresponding to 10 fixations. Low values (dark) indicate poor evidence for activity differences, while high values (bright) indicate strong evidence. The dark squares along the main diagonal each correspond to the forty second intervals in which the activity was held constant; the 4x4 block at the lower left corresponds to the four leave-one-out activities, while the 6x6 block in the upper right corresponds to the leave-two-out activities. (The anti-diagonal pattern of white squares indicates those activity pairs that share no AOIs.) The chi-square values can be binarized by choosing a particular significance level; we are interested in grouping bins that represent the same activity, effectively accepting the null hypothesis. Therefore, we may adopt a relatively lax criterion; for example, choosing a p-value of 0.2 means that two behaviors that have only a 1-in-5 chance of being produced by a single activity might nevertheless be clustered together. We have explored several methods to perform clustering on the data and solving for the activity probabilities. Greedy methods begin by selecting the time bin that is similar to the most (or least) other bins, and then forming a cluster from it and all other non-discriminable bins. These methods show mediocre performance, as they do not take into account temporal contiguity. Preliminary results indicate that methods that "grow" clusters in time from seed points perform better.

activity analysis↗

Atomic-scale factors that control the rate capability of nanostructured amorphous Si for high-energy-density batteries

Nanostructured Si is the most promising high-capacity anode material to substantially increase the energy density of Li-ion batteries. Among the remaining challenges is its low rate capability as compared to conventional materials. To understand better what controls the diffusion of Li in the amorphous Li-Si alloy, we use a novel machine-learning potential trained on more than 40,000 ab-initio calculations and nanosecond-scale molecular dynamics simulations, to visualize for the first time the delithiation of entire LiSi nanoparticles. Our results show that the Si host is not static but undergoes a dynamic rearrangement from isolated atoms, to chains, and clusters, with the Li diffusion strongly governed by this Si rearrangement. We find that the Li diffusivity is highest when Si segregates into clusters, so that Li diffusion proceeds via hopping between the Si clusters. The average size of Si clusters and the concentration range over which Si clustering occurs can thus function as design criteria for the development of rate-improved anodes based on modified Si.

Artrith, Nongnuch↗

Web-based Preprocessing and Visualization of 3D FIB Tomography Data for Nuclear Fuel Characterization

Three-dimensional (3D) focused ion beam (FIB) tomography enables reconstruction of internal nuclear fuel features that can't be fully evaluated through surface imaging alone. This capability supports characterization of fuel constituents and defects under thermal and irradiation conditions relevant to microreactor development. However, large tomography datasets can create data-handling, loading, and visualization challenges, especially when image-stack preparation and file conversion must be completed with separate tools. The Computational Ultraspatial Tomography Toolkit for High-Resolution Object Analysis Tools (CUTTRHOAT) is an open-source web application being developed to display FIB tomography datasets available through the Nuclear Research Data System (NRDS). The current alpha version requires prepared HDF5 datasets and has limited integrated data-preparation capabilities. This project improves CUTTHROAT by adding dataset-folder selection, automatic input detection, dataset scanning, missing-slice identification, blank-slice insertion, and image-stack-to-HDF5 conversion. Two applications will be compared: the baseline CUTTHROAT alpha workflow and the updated application containing the integrated data-handling and preprocessing functions. Evaluation will consider dataset detection accuracy, conversion success, loading time, rendering responsiveness, application stability, and user interaction. Preliminary results demonstrate successful loading of existing HDF5 files and converted image stacks, while testing also identified performance reductions caused by excessive blank-slice generation. The updated workflow reduces reliance on external preparation tools and supports more direct movement from image stacks to color-code 3D visualization. Future work includes refining missing-slice handling, integrating additional preprocessing functions, like a denoising feature, parsing TIFF metadata for automatic voxel scaling, and adding manual X, Y, and Z voxel-spacing inputs for PNG and JPEG.

36 - MATERIALS SCIENCE↗

Infrared Camera System for Visualization of IR-Absorbing Gas Leaks

Leak detection and location remain a common problem in NASA and industry, where gas leaks can create hazardous conditions if not quickly detected and corrected. In order to help rectify this problem, this design equips an infrared (IR) camera with the means to make gas leaks of IR-absorbing gases more visible for leak detection and location. By comparing the output of two IR cameras (or two pictures from the same camera under essentially identical conditions and very closely spaced in time) on a pixel-by-pixel basis, one can cancel out all but the desired variations that correspond to the IR absorption of the gas of interest. This can be simply done by absorbing the IR lines that correspond to the gas of interest from the radiation received by one of the cameras by the intervention of a filter that removes the particular wavelength of interest from the "reference" picture. This can be done most sensitively with a gas filter (filled with the gas of interest) placed in front of the IR detector array, or (less sensitively) by use of a suitable line filter in the same location. This arrangement would then be balanced against the unfiltered "measurement" picture, which will have variations from IR absorption from the gas of interest. By suitable processing of the signals from each pixel in the two IR pictures, the user can display only the differences in the signals. Either a difference or a ratio output of the two signals is feasible. From a gas concentration viewpoint, the ratio could be processed to show the column depth of the gas leak. If a variation in the background IR light intensity is present in the field of view, then large changes in the difference signal will occur for the same gas column concentration between the background and the camera. By ratioing the outputs, the same signal ratio is obtained for both high- and low-background signals, even though the low-signal areas may have greater noise content due to their smaller signal strength. Thus, one embodiment would use a ratioed output signal to better represent the gas column concentration. An alternative approach uses a simpler multiplication of the filtered signal to make the filtered signal equal to the unfiltered signal at most locations, followed by a subtraction to remove all but the wavelength-specific absorption in the unfiltered sample. This signal processing can also reveal the net difference signal representing the leaking gas absorption, and allow rapid leak location, but signal intensity would not relate solely to gas absorption, as raw signal intensity would also affect the displayed signal. A second design choice is whether to use one camera with two images closely spaced in time, or two cameras with essentially the same view and time. The figure shows the two-camera version. This choice involves many tradeoffs that are not apparent until some detailed testing is done. In short, the tradeoffs involve the temporal changes in the field picture versus the pixel sensitivity curves and frame alignment differences with two cameras, and which system would lead to the smaller variations from the uncontrolled variables.

Youngquist, Robert↗

Lighting and visual comfort performance of commercially available tubular daylight devices

Tubular daylight devices (TDDs) require a much smaller roof opening than conventional skylights and, because of their highly reflective tube, they can deliver daylight farther away from the building envelope. This can provide lighting energy savings, increasing resilience in new and existing buildings. Different types and configurations are available amongst commercially available TDDs, including domes/diffusers with varying optical properties and the diameter of the TDD. This paper presents a comprehensive experimental evaluation of the lighting and visual comfort performance of multiple configurations of commercially available TDDs, varying dome type (prismatic and clear), diffuser type (Fresnel and prismatic), and diameter (53 and 35 cm), under a range of environmental conditions (different times of day/year, sky cover). Based on illuminance measurements, estimated lighting energy use is also presented. Results indicate that, for clear sky, light levels increase and energy use decreases with solar altitude (e.g., 16 Wh/m 2 daily energy use intensity on a high maximum daily solar altitude (MDSA) day and 34 Wh/m 2 on a low MDSA day) and TDD diameter (e.g., 34 Wh/m 2 and 69 Wh/m 2 for 53 cm and 35 cm TDDs, respectively, for low MDSA). The daily illuminance profile is more rounded for prismatic domes and has higher peaks for clear domes; this translates into a somewhat higher average daily useful daylight illuminance (DUDI) for prismatic domes (86 %) when compared to clear domes (80 %). No clear impact of diffuser type was apparent. In conclusion, measurements indicated no discomfort glare for any of the conditions tested.

14 SOLAR ENERGY↗

Development of Gravity-Sensing Organs in Altered Gravity Conditions: Opposite Conclusions From an Amphibian and a Molluscan Preparation

Several components of the systems animals use to orient to gravity might develop differently in micrograms. If the growth of the "test masses" on which gravity acts (otoliths, in vertebrates, statoliths or statoconia in most invertebrates) is controlled on the basis of their weight, larger otoliths (or their analogs) would be expected to develop in micrograms. The vestibular systems in animals reared in altered gravity have been studied in several species, with varied results being reported. Early Russian reports of Xenopus larvae reared in space indicated no qualitative differences in the vestibular organs, compared to ground-reared controls. A similar lack of differences in Xenopus were reported. The ultricular otolith was 30% larger in space-reared Xenopus. No differences in saccular otolith volume between centrifuged and control adult rats were found. A delay in otoconial development in chick embryos reared at 2 grams on a centrifuge was reported but in a later report, no differences in otolith weight between 2 grams and control chicks were found. Increased optokinetic responses in flight-reared Xenopus tadpoles, suggesting that the animals reared in the absence of gravity made greater relative use of their visual system, rather than the vestibular system, in orienting to a moving stimulus was reported. To test early Japanese newt, CYnops pyrrhogaster, were maintained in orbit for 15 days on the IML-2 mission in 1994. All specimens reached orbit before any otoconia were formed and all major components of the inner ear were formed by the end of the flight. In ground-based studies of he Aplysia statocyst, the volume of the statolith in embryos and the number statoconia in post-metamorphic animals were compared between 1-gram controls and specimens reared at 2 to 5.7 grams.

Wiederhold, Michael L.↗

Mass Spectrometry Imaging of Biological Tissue: An Approach for Multicenter Studies

Mass spectrometry imaging has become a popular tool for probing the chemical complexity of biological surfaces. This led to the development of a wide range of instrumentation and preparation protocols. It is thus desirable to evaluate and compare the data output from different methodologies and mass spectrometers. Here, we present an approach for the comparison of mass spectrometry imaging data from different laboratories (often referred to as multicenter studies). This is exemplified by the analysis of mouse brain sections in five laboratories in Europe and the USA. The instrumentation includes matrix-assisted laser desorption/ionization (MALDI)-time-of-flight (TOF), MALDI-QTOF, MALDIFourier transform ion cyclotron resonance (FTICR), atmospheric-pressure (AP)-MALDI-Orbitrap, and cluster TOF-secondary ion mass spectrometry (SIMS). Experimental parameters such as measurement speed, imaging bin width, and mass spectrometric parameters are discussed. All datasets were converted to the standard data format imzML and displayed in a common open-source software with identical parameters for visualization, which facilitates direct comparison of MS images. The imzML conversion also allowed exchange of fully functional MS imaging datasets between the different laboratories. The experiments ranged from overview measurements of the full mouse brain to detailed analysis of smaller features (depending on spatial resolution settings), but common histological features such as the corpus callosum were visible in all measurements. High spatial resolution measurements of AP-MALDI-Orbitrap and TOF-SIMS showed comparable structures in the low-micrometer range. We discuss general considerations for planning and performing multicenter studies in mass spectrometry imaging. This includes details on the selection, distribution, and preparation of tissue samples as well as on data handling. Such multicenter studies in combination with ongoing activities for reporting guidelines, a common data format (imzML) and a public data repository can contribute to more reliability and transparency of MS imaging studies.

Environmental Molecular Sciences Laboratory↗

Physiological impact of nanoporous acupuncture needles: Laser Doppler perfusion imaging in healthy volunteers

Recently, porous acupuncture (PA), which is anodized to increase its surface area for higher stimulation intensity, was developed and showed significantly improved therapeutic effects with more comfort as compared with original acupuncture (OA) in vivo. However, the impact of PA on the change of local blood flow as well as its efficacy and acceptability has not yet been confirmed in a clinical trial. In a randomized, controlled crossover clinical trial, we investigated the effects of PA on the change in local blood flow using laser Doppler perfusion imaging and considered the sensation of pain intensity and discomfort severity using a visual analogue scale (VAS) to explore its physiological impact and the possibility of PA in clinical use. Twenty-one healthy participants were randomly treated with PA or OA on one side of Zusanli (ST36) and each participant served as his or her own control. Baseline local blood flow and galvanic skin response (GSR) were obtained for 5 min and acupuncture interventions were subsequently performed. Next, local blood flow and GSR were subsequently obtained for 10 min after insertion, 10 min after manipulation, and 5 min after the withdrawal of acupuncture. At the end of the experiment, participants were asked to indicate the sensation of pain intensity at each session of insertion, retention, manipulation, and withdrawal as well as the overall pain intensity and discomfort severity. PA significantly increased the local blood flow as compared with OA and there was no significant difference in GSR between patients treated with PA versus OA in each phase of insertion and manipulation. No significant difference in pain intensity or discomfort severity was found during manipulation, retention, or withdrawal of acupuncture. These results indicate that PA increases local blood flow, which can be closely related to the observed enhanced performance, without any associated discomfort or pain, suggesting its applicability in clinical practice.

59 BASIC BIOLOGICAL SCIENCES↗

Histological Comparison of Kidney Tissue Following Radioembolization with Yttrium-90 Resin Microspheres and Embolization with Bland Microspheres

BackgroundIntra-arterial brachytherapy with yttrium-90 ({sup 90}Y) resin microspheres (radioembolization) is a procedure to selectively deliver high-dose radiation to tumors. The purpose of this research was to compare the radioembolic effect of {sup 90}Y-radioembolization versus the embolic effect of bland microspheres in the porcine kidney model.MethodsIn each of six pigs, ~25–33 % of the kidney volume was embolized with {sup 90}Y resin microspheres and an equivalent number of bland microspheres in the contralateral kidney. Kidney volume was estimated visually from contrast-enhanced fluoroscopy imaging. Morphologic and histologic analysis was performed 8–9 weeks after the procedure to assess the locations of the microspheres and extent of tissue necrosis from {sup 90}Y-radioembolization and bland embolization. A semi-quantified evaluation of the non-acute peri-particle and perivascular tissue reaction was conducted. All guidelines for the care and use of animals were followed.ResultsKidneys embolized with {sup 90}Y-radioembolization decreased in mass by 30–70 % versus the contralateral kidney embolized with bland microspheres. These kidneys showed significant necrosis/fibrosis, avascularization, and glomerular atrophy in the immediate vicinity of the {sup 90}Y resin microspheres. By contrast, glomerular changes were not observed, even with clusters of bland microspheres in afferent arterioles. Evidence of a foreign body reaction was recorded in some kidneys with bland microspheres, and subcapsular scarring/infarction only with the highest load (4.96 × 10{sup 6}) of bland microspheres.ConclusionThis study showed that radioembolization with {sup 90}Y resin microspheres produces localized necrosis/fibrosis and loss of kidney mass in a porcine kidney model. This result supports the study of {sup 90}Y resin microspheres for the localized treatment of kidney tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synchrotron-based double imaging photoelectron/photoion coincidence spectroscopy of radicals produced in a flow tube: OH and OD

We present a microwave discharge flow tube coupled with a double imaging electron/ion coincidence device and vacuum ultraviolet (VUV) synchrotron radiation. The system has been applied to the study of the photoelectron spectroscopy of the well-known radicals OH and OD. The coincidence imaging scheme provides a high selectivity and yields the spectra of the pure radicals, removing the ever-present contributions from excess reactants, background, or secondary products, and therefore obviating the need for a prior knowledge of all possible byproducts. The photoelectron spectra encompassing the X{sup 3}Σ{sup −} ground state of the OH{sup +} and OD{sup +} cations have been extracted and the vibrational constants compared satisfactorily to existing literature values. Future advantages of this approach include measurement of high resolution VUV spectroscopy of radicals, their absolute photoionization cross section, and species/isomer identification in chemical reactions as a function of time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Integrity Challenges in NASA Giovanni

The Geospatial Interactive Online Visualization ANd aNalysis Infrastructure (Giovanni) is an online tool developed by the NASA Goddard Earth Sciences (GES) Data and Information Services Center (DISC), one of 12 NASA Science Mission Directorate Data Centers (DAACs) to analyze and visualize NASA remote sensing and model data without downloading data and software. As of this writing, over 2000 Earth satellite and model variables are available in Giovanni, including several well-known NASA satellite missions (e.g., TRMM, GPM) and projects (e.g., MERRA-2, GPCP). There are twenty-two plots provided by Giovanni that can be used to analyze, compare, and explore Earth data across disciplines. Results can be shared with colleagues and downloaded for further analysis. Giovanni has helped publish over 3000 referral papers over the years. As open science policies roll in, data integrity has become a major challenge for Giovanni and other tools. For integrity, both data and workflows must be transparent. FAIR-compliant data, including input, intermediate, and result products, as well as their associated statistics, metadata, and information, are needed. The NASA Data Product Development Guide for Data Producers provides a key resource on how to develop FAIR-compliant data products. Data quality information is also needed from data producers and analysis services like Giovanni. The workflow part is quite challenging and requires workflow management improvements, such as recording workflows and making them available to users. In this presentation, we will discuss the data integrity challenges in Giovanni.

data analysis, visualization↗

Liquid-Like, Self-Healing Aluminum Oxide during Deformation at Room Temperature

Effective protection from environmental degradation relies on the integrity of oxide as diffusion barriers. Ideally, the passivation layer can repair its own breaches quickly under deformation. While studies suggest that the native aluminum oxide may manifest such properties, it has yet to be experimentally proven because direct observations of the air-environmental deformation of aluminum oxide and its initial formation at room temperature are challenging. In this letter, we report in situ experiments to stretch pure aluminum nanotips under O 2 gas environments in a transmission electron microscope (TEM). We discovered that aluminum oxide indeed deforms like liquid and can match the deformation of Al without any cracks/spallation at moderate strain rate. At higher strain rate, we exposed fresh metal surface, and visualized the self-healing process of aluminum oxide at atomic resolution. Unlike traditional thin-film growth or nanoglass consolidation processes, we observe seamless coalescence of new oxide islands without forming any glass–glass interface or surface grooves, indicating greatly accelerated glass kinetics at the surface compared to the bulk.

36 MATERIALS SCIENCE↗

Dosimetry concepts for scanner quality assurance and tissue dose assessment in micro-CT

Purpose: At present, no established methods exist for dosimetry in micro computed tomography (micro-CT). The purpose of this study was therefore to investigate practical concepts for both dosimetric scanner quality assurance and tissue dose assessment for micro-CT. Methods: The computed tomography dose index (CTDI) was adapted to micro-CT and measurements of the CTDI both free in air and in the center of cylindrical polymethyl methacrylate (PMMA) phantoms of 20 and 32 mm diameter were performed in a 6 month interval with a 100 mm pencil ionization chamber calibrated for low tube voltages. For tissue dose assessment, z-profile measurements using thermoluminescence dosimeters (TLDs) were performed and both profile and CTDI measurements were compared to Monte Carlo (MC) dose calculations to validate an existing MC tool for use in micro-CT. The consistency of MC calculations and TLD measurements was further investigated in two mice cadavers. Results: CTDI was found to be a reproducible quantity for constancy tests on the micro-CT system under study, showing a linear dependence on tube voltage and being by definition proportional to mAs setting and z-collimation. The CTDI measured free in air showed larger systematic deviations after the 6 month interval compared to the CTDI measured in PMMA phantoms. MC calculations were found to match CTDI measurements within 3% when using x-ray spectra measured at our micro-CT installation and better than 10% when using x-ray spectra calculated from semi-empirical models. Visual inspection revealed good agreement for all z-profiles. The consistency of MC calculations and TLD measurements in mice was found to be better than 10% with a mean deviation of 4.5%. Conclusions: Our results show the CTDI implemented for micro-CT to be a promising candidate for dosimetric quality assurance measurements as it linearly reflects changes in tube voltage, mAs setting, and collimation used during the scan, encouraging further studies on a variety of systems. For tissue dose assessment, MC calculations offer an accurate and fast alternative to TLD measurements allowing for dose calculations specific to any geometry and scan protocol.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Soft X-Ray Tomography Has Evolved into a Powerful Tool for Revealing Cell Structures

Over the past three decades, soft X-ray tomography (SXT) has rapidly evolved from a proof-of-concept microscopy method into a high-throughput quantitative imaging modality. This advancement enables researchers to address central questions in cell biology. Despite its relatively short developmental period compared to light and electron microscopy, SXT has emerged as a powerful imaging technology. It enables measuring chemical changes in cellular organelles, analyzing three-dimensional structures of whole cells and creating digital cellular models to study cell motility. We discuss the unique nature of SXT to visualize cells without fixation or labeling, enabling quantitative analyses of organelle chemical composition. We explore SXT microscopes available worldwide, SXT segmentation software, and the diverse cell types studied using this technique. We conclude with emerging directions in SXT imaging, including a brief discussion of recent discoveries that are highly influential and likely to become integral to cell biology textbooks.

Weinhardt, Venera↗

FINAL REPORT

Excellent progress was made in standardizing three complementary methods: Magnetic resonance imaging, x-ray micro CT, and MALDI imaging linear ion trap mass spectroscopy to image biomass and chemical, anatomical and functional changes that occur during pretreatment and hydrolysis. Magnetic resonance microscopy provides excellent images with as low as 5 uM resolution with hydrated biomass samples. We visualized dramatic changes in signal associated with the hydrolysis of the carbohydrates by strong acids. Quantitative diffusion approaches were used to probe more subtle structural changes in biomass. Diffusion tensor calculations reflect diffusion anisotropy and fractional anisotropy maps clearly show the longer range diffusion within the vessels compared to within the fiber cells. The diffusion is increased along the cell walls of the vessels. Suggesting that further research with NMR imaging should be pursued. X-ray CT provides excellent images at as low as 3.5 uM resolution from dried biomass. Small increases in surface area, and decreases in local density have been quantified in with wood after mild pretreatments; these changes are expected to be underestimates of the hydrated wood, due to the ~12% shrinkage that occurs upon drying untreated wood. MALDI-MS spectra show high ion intensities at most mass to charge ratios in untreated and pretreated woody material. MALDI-MSn is required to improve specificity and reduce background for imaging. MALDI-TOF is not specific enough for carbohydrate identification. Using MALDI-LIT/MSn we can readily identify oligomeric glucans and xylans and their fragmentation patterns as well as those of the glucuronic acid side chains of birch 4-O-methyl glucuronxylan. Imaging of glucan and xylan oligomers show that many contain isobaric ions with different distributions, indicating again that MSn is needed for accurate imaging of lignocellulosic materials. We are now starting to integrate the three imaging methods by using the same set of biomass samples imaged with all three methods, and using common analytical software to quantify parameters from the three dimensional images. In addition to the proposed experiments, we conducted imaging studies with a novel TOF-SIMS instrument available through collaborations with the AMOLF goup led by Ron Heeren at the FOM Institute in Amersterdam, Netherlands. ToF-SIMS was used to image intact cross sections of Populus stems with high spatial resolution, chemically selectivity. ToF-SIMS images were correlated with fluorescence microscopy which allowed for more positive ion identification.

09 BIOMASS FUELS↗

Visual Orbits of Spectroscopic Binaries with the CHARA Array. III. HD 8374 and HD 24546

We present the visual orbits of two long-period spectroscopic binary stars, HD 8374 and HD 24546, using interferometric observations acquired with the CHARA Array and the Palomar Testbed Interferometer. We also obtained new radial velocities from echelle spectra using the APO 3.5 m and Fairborn 2.0 m telescopes. By combining the visual and spectroscopic observations, we solve for the full, three-dimensional orbits and determine the stellar masses and distances to within 3% uncertainty. We then estimate the effective temperature and radius of each component star through Doppler tomography and spectral energy distribution analyses, in order to compare the observed stellar parameters to the predictions of stellar evolution models. For HD 8374, we find masses of M {sub 1} = 1.636 ± 0.050M {sub ⊙} and M {sub 2} = 1.587 ± 0.049M {sub ⊙}, radii of R {sub 1} = 1.84 ± 0.05R {sub ⊙} and R {sub 2} = 1.66 ± 0.12R {sub ⊙}, temperatures of T{sub eff1}=7280±110 K and T{sub eff2}=7280±120 K, and an estimated age of 1.0 Gyr. For HD 24546, we find masses of M {sub 1} = 1.434 ± 0.014M {sub ⊙} and M {sub 2} = 1.409 ± 0.014M {sub ⊙}, radii of R {sub 1} = 1.67 ± 0.06R {sub ⊙} and R {sub 2} = 1.60 ± 0.10R {sub ⊙}, temperatures of T{sub eff1}=6790±120 K and T{sub eff2}=6770±90 K, and an estimated age of 1.4 Gyr. HD 24546 is therefore too old to be a member of the Hyades cluster, despite its physical proximity to the group.

79 ASTRONOMY AND ASTROPHYSICS↗