Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Design of a Multi-Chemistry Battery Pack System for Behind-the-Meter Storage Applications

Battery management systems (BMS) are essential for a battery pack's safe operation and longevity. This paper presents an active balancing method-based BMS for different cell chemistry structures to be used in behind-the-meter storage (BTMS) applications. The proposed system utilizes modular isolated dual active bridge (DAB) DC/DC converters to actively balance the battery pack through a low voltage (LV) bus. A supervisory controller monitors all the cell voltage, current, and state of charge (SOC) values. Based on the estimation of the SOCs, reference currents for the DAB converters are generated by the supervisory controller. Detailed modeling and the control approach of the modular DAB converters are presented in the paper. Moreover, the control strategy of the supervisory control is also analyzed. The proposed method and structure can be extended to any combination of the number of cells to design the battery pack. Simulation results are provided for a system consisting of three cells in parallel to form a cell block and three cell blocks in series to form the battery module. Experimental results are provided for three modular DAB converters operating with a LiFeMnPO4 prismatic cell with 3.2V, 20Ah rated values.

battery management systems↗

Curriculum-based Reinforcement Learning for Distribution System Critical Load Restoration

This paper focuses on the critical load restoration problem in distribution systems following major outages. To provide fast online response and optimal sequential decision-making support, a reinforcement learning (RL) based approach is proposed to optimize the restoration. Due to the complexities stemming from the large policy search space, renewable uncertainty, and nonlinearity in a complex grid control problem, directly applying RL algorithms to train a satisfactory policy requires extensive tuning to be successful. To address this challenge, this paper leverages the curriculum learning (CL) technique to design a training curriculum involving a simpler steppingstone problem that guides the RL agent to learn to solve the original hard problem in a progressive and more effective manner. We demonstrate that compared with direct learning, CL facilitates controller training to achieve better performance. To study realistic scenarios where renewable forecasts used for decision-making are in general imperfect, the experiments compare the trained RL controllers against two model predictive controllers (MPCs) using renewable forecasts with different error levels and observe how these controllers can hedge against the uncertainty. Results show that RL controllers are less susceptible to forecast errors than the baseline MPCs and can provide a more reliable restoration process.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental Demonstration of Frequency Regulation by Commercial Buildings – Part I: Modeling and Hierarchical Control Design

Here, this paper is the first part of a two-part series in which we present results from one of the first worldwide experimental demonstrations of frequency regulation in a commercial building test facility. We demonstrate that commercial buildings can track a frequency regulation signal with high accuracy and minimal occupant discomfort in a realistic environment. In addition, we show that buildings can determine the reserve capacity and baseline power a priori, and identify the optimal tradeoff between frequency regulation and energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Framework for Multi Layer Control in Python (FMLC) v1.0

This package is developed as a backend for multi-layer and multi-time domain controller. One example are controller based on [Model Predictive Control] (MPC) where different modules with different time constants have to be coordinated to allow optimal control. In a simple example, the Weather Forecast must be acquired and processed, the MPC is computed, and finally the control is applied. All these modules typically run on the same time step (Time step: 5 minutes), but are different instances within the framework. The framework allows parallelization using the `multiprocessing` module. However, another real-time controller (Time step: 1 second) must be applied to react on instant system disturbances beyond the MPC time step. Last, a supervisory MPC controller (Time step: 1 hour) might be added to ensure global optimality.

Gehbauer, Christoph↗

A control-oriented combustion model framework for compression ignition engines operating on low-reactivity fuel

This work focuses on zero-dimensional modeling of the heat release rate in a compression ignition engine operating on gasoline-like fuels. Due to the properties of gasoline, such as high volatility and longer ignition delay than diesel, the injection strategies can vary significantly from the operation with conventional diesel fuel. Different injection strategies are commonly used to achieve varying degrees of in-cylinder stratification in order to shape the combustion event and maximize efficiency. The proposed zero-dimensional combustion model was developed to account for the different stages in combustion caused by the fuel stratification. As the ignition delay model is an integral part of the entire combustion process and significantly affects the prediction accuracy, special attention has been paid to local phenomena influencing ignition delay. A one-dimensional spray model by Musculus and Kattke was employed in conjunction with a Lagrangian tracking approach in order to estimate the local air–fuel ratio within the spray tip, as a proxy for reactivity. The local air–fuel ratio, in-cylinder temperature and pressure were used in an integral fashion to estimate the ignition delay. Heat release rates were modeled using first-order non-linear differential equations. The proposed combustion model was validated against experimental data of a heavy-duty compression ignition engine with up to three injection events at mostly 1038 r/min and 14 bar brake mean effective pressure. Further validation of the model was carried out at other engine loads and speeds. Model prediction errors in CA50 of less than 1 °CA across all conditions were found. Modeling results of other combustion metrics such as combustion duration and indicated mean effective pressure are also highly satisfactory. In addition, the model has been shown to be capable of estimating the ringing intensity for most conditions.

Pamminger, Michael↗

Advanced Process Control and Dynamic Optimization of Reversible Solid Oxide Cell Systems for Performance and Long-Term Health

This presentation was delivered at the 2024 Hydrogen Annual Merit Review Meeting. It focuses on three aspects of projects focusing on solid oxide cell systems- advanced control including nonlinear model predictive control and traditional control, dynamic optimization with due consideration of chemical degradation over the cell lifetime, dynamic optimization considering physical degradation.

Allan, Douglas↗

Moving Beyond Direct Load Control: A Maturity Model for Realizing the Promise of Demand Flexibility

This report discusses a new maturity model that regulators and utilities can use to guide and expand demand flexibility programs and enable the resources to provide more grid services. The model has six demand flexibility categories: planning and design; customer engagement; program operations; evaluation, measurement and verification; distributed energy resource orchestration; and data infrastructure. Within each category, capabilities are identified and described on a maturity scale that ranges from performing below expectations to improving on best practices.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fuzzy Integration of Support Vector Regression Models for Anticipatory Control of Complex Energy Systems

Anticipatory control systems are a class of systems whose decisions are based on predictions for the future state of the system under monitoring. Anticipation denotes intelligence and is an inherent property of humans that make decisions by projecting in future. Likewise, artificially intelligent systems equipped with predictive functions may be utilized for anticipating future states of complex systems, and therefore facilitate automated control decisions. Anticipatory control of complex energy systems is paramount to their normal and safe operation. In this paper a new intelligent methodology integrating fuzzy inference with support vector regression is introduced. Our proposed methodology implements an anticipatory system aiming at controlling energy systems in a robust way. Initially a set of support vector regressors is adopted for making predictions over critical system parameters. Furthermore, the predicted values are fed into a two stage fuzzy inference system that makes decisions regarding the state of the energy system. The inference system integrates the individual predictions into a single one at its first stage, and outputs a decision together with a certainty factor computed at its second stage. The certainty factor is an index of the significance of the decision. The proposed anticipatory control system is tested on a real world set of data obtained from a complex energy system, describing the degradation of a turbine. Results exhibit the robustness of the proposed system in controlling complex energy systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analytical verification of undesirable properties of direct model reference adaptive control algorithms

The present investigation is concerned with a new method, called 'final approach analysis', which has been developed to analyze the dynamic properties of a class of direct adaptive control algorithms. Particular attention is given to the robustness of these algorithms to a number of aspects. These aspects are related to the generation of high frequencies in the plant control signal, to excessive bandwidth of the adaptive control loop resulting in excitation of unmodeled dynamics, and, consequently, leading to dynamic instability of the closed-loop adaptive system, and, thirdly, to noise corrupted measurements. The final approach analysis is useful because it can be used in a constructive way to adjust the adaptive gains so as to limit the closed-loop system bandwidth and to ameliorate some of the undesirable characteristics of existing adaptive algorithms.

Rohrs, C. E.↗

Transonic steady- and unsteady-pressure measurements on a high-aspect-ratio supercritical-wing model with oscillating control surfaces

A supercritical wing with an aspect ratio of 10.76 and with two trailing-edge oscillating control surfaces is described. The semispan wing is instrumented with 252 static orifices and 164 in situ dynamic-pressure gages for studying the effects of control-surface position and motion on steady- and unsteady-pressures at transonic speeds. Results from initial tests conducted in the Langley Transonic Dynamics Tunnel at two Reynolds numbers are presented in tabular form.

Sandford, M. C.↗