At least 1,711 records · Page 95

Information Technology and Community Restoration Studies/Task 1: Information Technology

Executive Summary The Interagency Biological Restoration Demonstration—a program jointly funded by the Department of Defense's Defense Threat Reduction Agency and the Department of Homeland Security's (DHS's) Science and Technology Directorate—is developing policies, methods, plans, and applied technologies to restore large urban areas, critical infrastructures, and Department of Defense installations following the intentional release of a biological agent (anthrax) by terrorists. There is a perception that there should be a common system that can share information both vertically and horizontally amongst participating organizations as well as support analyses. A key question is: "How far away from this are we?" As part of this program, Pacific Northwest National Laboratory conducted research to identify the current information technology tools that would be used by organizations in the greater Seattle urban area in such a scenario, to define criteria for use in evaluating information technology tools, and to identify current gaps. Researchers interviewed 28 individuals representing 25 agencies in civilian and military organizations to identify the tools they currently use to capture data needed to support operations and decision making. The organizations can be grouped into five broad categories: defense (Department of Defense), environmental/ecological (Environmental Protection Agency/Ecology), public health and medical services, emergency management, and critical infrastructure. The types of information that would be communicated in a biological terrorism incident include critical infrastructure and resource status, safety and protection information, laboratory test results, and general emergency information. The most commonly used tools are WebEOC (web-enabled crisis information management systems with real-time information sharing), mass notification software, resource tracking software, and NW WARN (web-based information to protect critical infrastructure systems). It appears that the current information management tools are used primarily for information gathering and sharing—not decision making. Respondents identified the following criteria for a future software system. It is easy to learn, updates information in real time, works with all agencies, is secure, uses a visualization or geographic information system feature, enables varying permission levels, flows information from one stage to another, works with other databases, feeds decision support tools, is compliant with appropriate standards, and is reasonably priced. Current tools have security issues, lack visual/mapping functions and critical infrastructure status, and do not integrate with other tools. It is clear that there is a need for an integrated, common operating system. The system would need to be accessible by all the organizations that would have a role in managing an anthrax incident to enable regional decision making. The most useful tool would feature a GIS visualization that would allow for a common operating picture that is updated in real time. To capitalize on information gained from the interviews, the following activities are recommended: • Rate emergency management decision tools against the criteria specified by the interviewees. • Identify and analyze other current activities focused on information sharing in the greater Seattle urban area. • Identify and analyze information sharing systems/tools used in other regions.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A Boundary Topology Optimization Approach for Lightweighting Electric Machines Inspired by Additive Manufacturing

Minimizing the mass in electric machines while maintaining superior performance has become a new requirement for the advancement of drivetrains used in wind energy and electric mobility. Topology optimization for light-weighting electric machines using traditional approaches typically explore a restricted design space allowed by standard parametrizable geometry and manufacturing, while advanced methods like cell-based density approaches suffer from a lack of robust manufacturability constraints during the optimization process. To overcome these drawbacks, we explore a grid-independent, boundary TO where the outer shape of the magnet is parameterized using Bezier curves. We conduct a design of experiments (DOE) to study the effect of different magnet shapes on machine performance by varying the control points on the Bezier curves. A machine-learning based surrogate model is constructed using the data from the DOE to quantify the relationship between the control points, air-gap torque and mass. The control points are then optimized to maximize the torque density. The approach is used for minimizing electrical steel mass in the IEA-15MW radial flux direct-drive wind turbine generator. The free-from boundary TO resulted in smooth and concise shapes that can be easily additively manufactured with upto 20-ton reduction in electrical steel mass.

additive manufacturing↗

A novel coupling of noise reduction algorithms for particle flow simulations

Proper orthogonal decomposition (POD) and its extension based on time-windows have been shown to greatly improve the effectiveness of recovering smooth ensemble solutions from noisy particle data. However, to successfully de-noise any molecular system, a large number of measurements still need to be provided. In order to achieve a better efficiency in processing time-dependent fields, we have combined POD with a well-established signal processing technique, wavelet-based thresholding. In this novel hybrid procedure, the wavelet filtering is applied within the POD domain and referred to as WAVinPOD. The algorithm exhibits promising results when applied to both synthetically generated signals and particle data. In this work, the simulations compare the performance of our new approach with standard POD or wavelet analysis in extracting smooth profiles from noisy velocity and density fields. Numerical examples include molecular dynamics and dissipative particle dynamics simulations of unsteady force- and shear-driven liquid flows, as well as phase separation phenomenon. Simulation results confirm that WAVinPOD preserves the dimensionality reduction obtained using POD, while improving its filtering properties through the sparse representation of data in wavelet basis. This paper shows that WAVinPOD outperforms the other estimators for both synthetically generated signals and particle-based measurements, achieving a higher signal-to-noise ratio from a smaller number of samples. The new filtering methodology offers significant computational savings, particularly for multi-scale applications seeking to couple continuum informations with atomistic models. It is the first time that a rigorous analysis has compared de-noising techniques for particle-based fluid simulations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Supercontinuum Fourier transform spectrometry with balanced detection on a single photodiode

We demonstrate a method of combining a supercontinuum light source with a commercial Fourier transform spectrometer, using a novel approach to dual-beam balanced detection, implemented with phase-sensitive detection on a single light detector. A 40 dB reduction in the relative intensity noise is achieved for broadband light, analogous to conventional balanced detection methods using two matched photodetectors. Unlike conventional balanced detection, however, this method exploits the time structure of the broadband source to interleave signal and reference pulse trains in the time domain, recording the broadband differential signal at the fundamental pulse repetition frequency of the supercontinuum. The method is capable of real-time correction for instability in the supercontinuum spectral structure over a broad range of wavelengths and is compatible with commercially designed spectrometers. A proof-of-principle experimental setup is demonstrated for weak absorption in the 1500-1600 nm region.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Loss of Matrix Metalloproteinase-13 Attenuates Murine Radiation-Induced Pulmonary Fibrosis

Purpose: Pulmonary fibrosis is a disorder of the lungs with limited treatment options. Matrix metalloproteinases (MMPs) constitute a family of proteases that degrade extracellular matrix with roles in fibrosis. Here we studied the role of MMP13 in a radiation-induced lung fibrosis model using a MMP13 knockout mouse. Methods and Materials: We investigated the role of MMP13 in lung fibrosis by investigating the effects of MMP13 deficiency in C57Bl/6 mice after 20-Gy thoracic irradiation (6-MV Linac). The morphologic results in histology were correlated with qualitative and quantitative results of volume computed tomography (VCT), magnetic resonance imaging (MRI), and clinical outcome. Results: We found that MMP13 deficient mice developed less pulmonary fibrosis than their wildtype counterparts, showed attenuated acute pulmonary inflammation (days after irradiation), and a reduction of inflammation during the later fibrogenic phase (5-6 months after irradiation). The reduced fibrosis in MMP13 deficient mice was evident in histology with reduced thickening of alveolar septi and reduced remodeling of the lung architecture in good correlation with reduced features of lung fibrosis in qualitative and quantitative VCT and MRI studies. The partial resistance of MMP13-deficient mice to fibrosis was associated with a tendency towards a prolonged mouse survival. Conclusions: Our data indicate that MMP13 has a role in the development of radiation-induced pulmonary fibrosis. Further, our findings suggest that MMP13 constitutes a potential drug target to attenuate radiation-induced lung fibrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reduced Acute Bowel Toxicity in Patients Treated With Intensity-Modulated Radiotherapy for Rectal Cancer

Purpose: We have previously shown that intensity-modulated radiotherapy (IMRT) can reduce dose to small bowel, bladder, and bone marrow compared with three-field conventional radiotherapy (CRT) technique in the treatment of rectal cancer. The purpose of this study was to review our experience using IMRT to treat rectal cancer and report patient clinical outcomes. Methods and Materials: A retrospective review was conducted of patients with rectal cancer who were treated at Mayo Clinic Arizona with pelvic radiotherapy (RT). Data regarding patient and tumor characteristics, treatment, acute toxicity according to the Common Terminology Criteria for Adverse Events v 3.0, tumor response, and perioperative morbidity were collected. Results: From 2004 to August 2009, 92 consecutive patients were treated. Sixty-one (66%) patients were treated with CRT, and 31 (34%) patients were treated with IMRT. All but 2 patients received concurrent chemotherapy. There was no significant difference in median dose (50.4 Gy, CRT; 50 Gy, IMRT), preoperative vs. postoperative treatment, type of concurrent chemotherapy, or history of previous pelvic RT between the CRT and IMRT patient groups. Patients who received IMRT had significantly less gastrointestinal (GI) toxicity. Sixty-two percent of patients undergoing CRT experienced {>=}Grade 2 acute GI side effects, compared with 32% among IMRT patients (p = 0.006). The reduction in overall GI toxicity was attributable to fewer symptoms from the lower GI tract. Among CRT patients, {>=}Grade 2 diarrhea and enteritis was experienced among 48% and 30% of patients, respectively, compared with 23% (p = 0.02) and 10% (p = 0.015) among IMRT patients. There was no significant difference in hematologic or genitourinary acute toxicity between groups. In addition, pathologic complete response rates and postoperative morbidity between treatment groups did not differ significantly. Conclusions: In the management of rectal cancer, IMRT is associated with a clinically significant reduction in lower GI toxicity compared with CRT. Further study is needed to evaluate differences in late toxicity and long-term efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Structure Effects on the Energetics of the Electrochemical Reduction of CO2 by Copper Surfaces

Polycrystalline copper electrocatalysts have been experimentally shown to be capable of reducing CO{sub 2} into CH{sub 4} and C{sub 2}H{sub 4} with relatively high selectivity, and a mechanism has recently been proposed for this reduction on the fcc(211) surface of copper, which was assumed to be the most active facet. In the current work, we use computational methods to explore the effects of the nanostructure of the copper surface and compare the effects of the fcc(111), fcc(100) and fcc(211) facets of copper on the energetics of the electroreduction of CO{sub 2}. The calculations performed in this study generally show that the intermediates in CO{sub 2} reduction are most stabilized by the (211) facet, followed by the (100) facet, with the (111) surface binding the adsorbates most weakly. This leads to the prediction that the (211) facet is the most active surface among the three in producing CH{sub 4} from CO{sub 2}, as well as the by-products H{sub 2} and CO. HCOOH production may be mildly enhanced on the more close-packed surfaces ((111) and (100)) as compared to the (211) facet, due to a change in mechanism from a carboxyl intermediate to a formate intermediate. The results are compared to experimental data on these same surfaces; the predicted trends in voltage requirements are consistent between the experimental and computational data.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-FG-207B-05: Iterative Reconstruction Via Prior Image Constrained Total Generalized Variation for Spectral CT

Purpose: To investigate iterative reconstruction via prior image constrained total generalized variation (PICTGV) for spectral computed tomography (CT) using fewer projections while achieving greater image quality. Methods: The proposed PICTGV method is formulated as an optimization problem, which balances the data fidelity and prior image constrained total generalized variation of reconstructed images in one framework. The PICTGV method is based on structure correlations among images in the energy domain and high-quality images to guide the reconstruction of energy-specific images. In PICTGV method, the high-quality image is reconstructed from all detector-collected X-ray signals and is referred as the broad-spectrum image. Distinct from the existing reconstruction methods applied on the images with first order derivative, the higher order derivative of the images is incorporated into the PICTGV method. An alternating optimization algorithm is used to minimize the PICTGV objective function. We evaluate the performance of PICTGV on noise and artifacts suppressing using phantom studies and compare the method with the conventional filtered back-projection method as well as TGV based method without prior image. Results: On the digital phantom, the proposed method outperforms the existing TGV method in terms of the noise reduction, artifacts suppression, and edge detail preservation. Compared to that obtained by the TGV based method without prior image, the relative root mean square error in the images reconstructed by the proposed method is reduced by over 20%. Conclusion: The authors propose an iterative reconstruction via prior image constrained total generalize variation for spectral CT. Also, we have developed an alternating optimization algorithm and numerically demonstrated the merits of our approach. Results show that the proposed PICTGV method outperforms the TGV method for spectral CT.

60 APPLIED LIFE SCIENCES↗

Density Measurement of NaCl-MgCl 2 -PuCl 3 and NaCl-UCl 3 -PuCl 3 Molten Salt Systems by Neutron Radiographic Dilatometry

A novel neutron radiographic technique was developed and implemented to measure the change in volume as a function of temperature of select plutonium-containing liquid chloride mixtures from melt to 1250 K. These measurements were performed at Los Alamos National Laboratory by members of the molten salt research group under support from Gateway for Accelerated Innovation in Nuclear (GAIN) voucher NE-21-25117: “Density Measurements of Plutonium Bearing Salts via Neutron Beam Dilatometry”. This technical report contains a description of the experimental method and a summary of the results. Initial characterization of the {NaCl, MgCl 2 , UCl 3 , PuCl 3 } salts used in this experiment includes a combination of x-ray diffraction, differential scanning calorimetry, gamma ray spectroscopy, and inductively coupled plasma mass spectrometry. Four samples of NaCl + MgCl 2 + x mol% PuCl 3 and four samples of NaCl + UCl 3 + x mol% PuCl 3 were prepared at the Plutonium Facility, shipped to the Los Alamos Neutron Science Center (LANSCE), and radiographed with the density via neutron radiography (DvNR) apparatus. Density data in the form of meniscus heights were recorded as a function of temperature. The results show a linear dependence of density with temperature and a third order polynomial dependence of density with composition as a function of PuCl 3 addition in the corresponding halide salt mixture. Additions of PuCl 3 result in a significant increase in density of the salt mixture and a slight reduction in the coefficient of volumetric expansion. These results represent a first measurement of the density of plutonium chloride salt mixtures and, in combination with additional measurements, may lead to a generalized description of the density of such salt systems for arbitrary compositions and temperature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Automated Groundwater Monitoring of Uranium at the Hanford Site, Washington - 13116

An automated groundwater monitoring system for the detection of uranyl ion in groundwater was deployed at the 300 Area Industrial Complex, Hanford Site, Washington. The research was conducted to determine if at-site, automated monitoring of contaminant movement in the subsurface is a viable alternative to the baseline manual sampling and analytical laboratory assay methods currently employed. The monitoring system used Arsenazo III, a colorimetric chelating compound, for the detection of the uranyl ion. The analytical system had a limit of quantification of approximately 10 parts per billion (ppb, μg/L). The EPA's drinking water maximum contaminant level (MCL) is 30 ppb [1]. In addition to the uranyl ion assay, the system was capable of acquiring temperature, conductivity, and river level data. The system was fully automated and could be operated remotely. The system was capable of collecting water samples from four sampling sources, quantifying the uranyl ion, and periodically performing a calibration of the analytical cell. The system communications were accomplished by way of cellular data link with the information transmitted through the internet. Four water sample sources were selected for the investigation: one location provided samples of Columbia River water, and the remaining three sources provided groundwater from aquifer sampling tubes positioned in a vertical array at the Columbia River shoreline. The typical sampling schedule was to sample the four locations twice per day with one calibration check per day. This paper outlines the instrumentation employed, the operation of the instrumentation, and analytical results for a period of time between July and August, 2012. The presentation includes the uranyl ion concentration and conductivity results from the automated sampling/analysis system, along with a comparison between the automated monitor's analytical performance and an independent laboratory analysis. Benefits of using the automated system as an alternative to traditional sample collection and analysis includes the following: - Field observations that provide more characterization information than is possible using traditional monitoring methods. - Potentially significant reductions in labor and analytical costs if traditional methods are complemented by automated systems. - The reduced cost of acquiring samples will allow for more frequent collection of samples that may be automatically introduced into real-time graphical flux programs allowing site managers to observe the changes in contaminant concentrations during remediation projects and across discrete river stage events. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AbacusHOD : a highly efficient extended multitracer HOD framework and its application to BOSS and eBOSS data

ABSTRACT We introduce the AbacusHOD model and present two applications of AbacusHOD and the AbacusSummit simulations to observations. AbacusHOD is a Halo Occupation Distribution (HOD) framework written in Python that is particle-based, multitracer, highly generalized, and highly efficient. It is designed specifically with multitracer/cosmology analyses for next-generation large-scale structure surveys in mind, and takes advantage of the volume and precision offered by the new state-of-the-art AbacusSummit cosmological simulations. The model is also highly customizable and should be broadly applicable to any upcoming surveys and a diverse range of cosmological analyses. In this paper, we demonstrate the capabilities of the AbacusHOD framework through two example applications. The first example demonstrates the high efficiency and the large HOD extension feature set through an analysis of full-shape redshift-space clustering of BOSS galaxies at intermediate to small scales ($\lt 30\, h^{-1}$ Mpc), assessing the necessity of introducing secondary galaxy biases (assembly bias). We find strong evidence for using halo environment instead of concentration to trace secondary galaxy bias, a result which also leads to a moderate reduction in the ‘lensing is low’ tension. The second example demonstrates the multitracer capabilities of the AbacusHOD package through an analysis of the extended Baryon Oscillation Spectroscopic Survey cross-correlation measurements between three different galaxy tracers: luminous red galaxies, emission-line galaxies, and quasi-stellar objects. We expect the AbacusHOD framework, in combination with the AbacusSummit simulation suite, to play an important role in a simulation-based analysis of the upcoming Dark Energy Spectroscopic Instrument data sets.

79 ASTRONOMY AND ASTROPHYSICS↗

Volumetric Modulated Arc Therapy for Delivery of Prostate Radiotherapy: Comparison With Intensity-Modulated Radiotherapy and Three-Dimensional Conformal Radiotherapy

Purpose: Volumetric modulated arc therapy (VMAT) is a novel form of intensity-modulated radiotherapy (IMRT) optimization that allows the radiation dose to be delivered in a single gantry rotation of up to 360{sup o}, using either a constant dose rate (cdr-VMAT) or variable dose rate (vdr-VMAT) during rotation. The goal of this study was to compare VMAT prostate RT plans with three-dimensional conformal RT (3D-CRT) and IMRT plans. Patients and Methods: The 3D-CRT, five-field IMRT, cdr-VMAT, and vdr-VMAT RT plans were created for 10 computed tomography data sets from patients undergoing RT for prostate cancer. The parameters evaluated included the doses to organs at risk, equivalent uniform doses, dose homogeneity and conformality, and monitor units required for delivery of a 2-Gy fraction. Results: The IMRT and both VMAT techniques resulted in lower doses to normal critical structures than 3D-CRT plans for nearly all dosimetric endpoints analyzed. The lowest doses to organs at risk and most favorable equivalent uniform doses were achieved with vdr-VMAT, which was significantly better than IMRT for the rectal and femoral head dosimetric endpoints (p < 0.05) and significantly better than cdr-VMAT for most bladder and rectal endpoints (p < 0.05). The vdr-VMAT and cdr-VMAT plans required fewer monitor units than did the IMRT plans (relative reduction of 42% and 38%, respectively; p = 0.005) but more than for the 3D-CRT plans (p = 0.005). Conclusion: The IMRT and VMAT techniques achieved highly conformal treatment plans. The vdr-VMAT technique resulted in more favorable dose distributions than the IMRT or cdr-VMAT techniques, and reduced the monitor units required compared with IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functional Image-Guided Radiotherapy Planning in Respiratory-Gated Intensity-Modulated Radiotherapy for Lung Cancer Patients With Chronic Obstructive Pulmonary Disease

Purpose: To investigate the incorporation of functional lung image-derived low attenuation area (LAA) based on four-dimensional computed tomography (4D-CT) into respiratory-gated intensity-modulated radiotherapy (IMRT) or volumetric modulated arc therapy (VMAT) in treatment planning for lung cancer patients with chronic obstructive pulmonary disease (COPD). Methods and Materials: Eight lung cancer patients with COPD were the subjects of this study. LAA was generated from 4D-CT data sets according to CT values of less than than -860 Hounsfield units (HU) as a threshold. The functional lung image was defined as the area where LAA was excluded from the image of the total lung. Two respiratory-gated radiotherapy plans (70 Gy/35 fractions) were designed and compared in each patient as follows: Plan A was an anatomical IMRT or VMAT plan based on the total lung; Plan F was a functional IMRT or VMAT plan based on the functional lung. Dosimetric parameters (percentage of total lung volume irradiated with {>=}20 Gy [V20], and mean dose of total lung [MLD]) of the two plans were compared. Results: V20 was lower in Plan F than in Plan A (mean 1.5%, p = 0.025 in IMRT, mean 1.6%, p = 0.044 in VMAT) achieved by a reduction in MLD (mean 0.23 Gy, p = 0.083 in IMRT, mean 0.5 Gy, p = 0.042 in VMAT). No differences were noted in target volume coverage and organ-at-risk doses. Conclusions: Functional IGRT planning based on LAA in respiratory-guided IMRT or VMAT appears to be effective in preserving a functional lung in lung cancer patients with COPD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Document-Based Nuclear Archaeology

Deeper reductions in the nuclear arsenals will require better understanding of historic fissile material management and production. The concept of “nuclear archaeology” has been considered since the 1990s to provide the tools and methods to develop independent production estimates, primarily based on nuclear forensic techniques. Here, we propose to add a framework for reconstructing the history of a nuclear program that complements traditional nuclear archaeology techniques by examining the role of operating records to support such an effort. As a test case, we use the JEEP II reactor, a 2 MW civilian research reactor at Norway’s Institute for Energy Technology (IFE), in operation for more than fifty years, however, recently shut down permanently. We have collected, analyzed, and started to preserve the reactor’s operating records, which exist on both analog and digital media, and to simulate parts of its history using OpenMC/ONIX neutronics calculations. Here, a particular focus of this project has been on digital data curation and preservation to confirm and maintain the integrity, authenticity, and provenance of these records. In developing guidelines for best practices that conform to existing standards for long-term digital preservation and curation, we hope this project can help lay the basis for future nuclear archaeology efforts to support nuclear arms control and disarmament.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Hydrodynamic Test Requirements Process Improvements

Hydrodynamic testing at Los Alamos National Laboratory would benefit from a process improvement for the requirements process. Cameo was used as a digital solution for requirements management to allow Lead Engineers to track requirements more effectively. This was identified as a process improvement throughout this Capstone project. This report includes a project proposal, business case, literature review, methodology, project plan, data analysis, decision-making report, financial analysis report, discussion, and conclusion. Initially, this project focused on figuring out a solution for the hydrotest requirement process improvements. The scope narrowed to focus on the use of Cameo for requirement capture and management. During this Capstone, four tests had digital models produced for requirements management in Cameo. The initial model was the baseline, with core requirements used across the tests. Commonalities in tests were used and the core requirements allowed for process efficiencies. In the data analysis, it was seen that overall, the implementation of using Cameo for requirements resulted in a decreasing trend for both schedule and normalized cost. Tests have different complexity levels which is also a factor in how long the requirements process will take. Additional data is needed to continue analyzing process improvements. Through decisionmaking and financial analysis, the recommendation was to use Cameo for requirements process improvement. Multiple experts provided feedback for requirements that were then captured within models. Numerous tangible and intangible benefits were identified with this process improvement. For return on investment, the metric of success was schedule reduction, which was overall seen. Four tests were analyzed, so future analysis will be needed. There is also not a great financial risk because the main cost would be purchasing more licenses. Individuals must generate requirements whether using this software or not. Overall, training is needed to help improve the skillsets of Lead Engineers but is already being supported on a regular frequency. A desktop guide was started associated with explaining the process, however, it is a work in progress. The team plans on adding additional information in the digital models to help status when requirements are met using verification methods and artifacts. From working on this project an improved understanding of Cameo and requirements was the result. There are future opportunities to extend the usage for requirements management and progress will continue after this project.

99 GENERAL AND MISCELLANEOUS↗

Cervical Cancer Regression Measured Using Weekly Magnetic Resonance Imaging During Fractionated Radiotherapy: Radiobiologic Modeling and Correlation With Tumor Hypoxia

Purpose: To measure regression of cancer of the uterine cervix during external beam radiotherapy using magnetic resonance imaging, derive radiobiologic parameters from a mathematical model of tumor regression, and compare these parameters with the pretreatment measurements of tumor hypoxia. Methods and Materials: A total of 27 eligible patients undergoing external beam radiotherapy for cervical cancer underwent weekly magnetic resonance imaging scans. The tumor volume was assessed on each of these scans and the rate of regression plotted. A radiobiologic model was formulated to simulate the effect on tumor regression of the surviving proportion of cells after 2 Gy (SP{sub 2}), the cell clearance constant (clearance of irreparably damaged cells from the tumor [T{sub c}]), and accelerated repopulation. Nonlinear regression analysis was used to fit the radiobiologic model to the magnetic resonance imaging-derived tumor volumes and to derive the estimates of SP{sub 2} and T{sub c} for each patient. These were compared to the pretreatment hypoxia measurements. Results: The initial tumor volume was 8-209 cm{sup 3}. The relative reduction in volume during treatment was 0.02-0.79. The simulations using representative values of the independent biologic variables derived from published data showed SP{sub 2} and T{sub c} to strongly influence the shape of the volume-response curves. Nonlinear regression analysis yielded a median SP{sub 2} of 0.71 and median T{sub c} of 10 days. Tumors with a high SP{sub 2} >0.71 were significantly more hypoxic at diagnosis (p = 0.02). Conclusion: The results of our study have shown that cervical cancer regresses during external beam radiotherapy, although marked variability is present among patients and is influenced by underlying biologic processes, including cellular sensitivity to radiotherapy and proliferation. Better understanding of the biologic mechanisms might facilitate novel adaptive treatment strategies in future studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Latest results from Double Chooz

Double Chooz is a short-baseline neutrino disappearance experiment. It detects ν̄{sub e }produced in the power plant of Chooz, France, where is located. The main goal of the experiment is the measurement of θ{sub 13} mixing angle and in 2011 for the first time the experiment observed an indication for a non zero value of such an oscillation parameter. The mixing angle was successively measured using only the far detector finding the best fit value of sin{sup 2}(2θ{sub 13}) = 0.090{sup +0.032}{sub −0.029} . The near detector is under construction and will start data taking by the middle of 2014 allowing the reduction of the systematic errors. In this paper I make a review of the Double Chooz experiment, focusing in particular on the latest results of the measurement of the mixing angle θ{sub 13} relying on the neutron absorption on Gadolinium. I also present results proving the capability of Double Chooz to identify the ortho-positronium. This has been done in an event-by-event basis for the first time in a large liquid scintillator experiments, and can be an additional handle for the electron/positron discrimination in future detectors based on such technology.

42 ENGINEERING↗

Dataset for 'Ombadi et al. (2023). A warming-induced reduction in snow fraction amplifies rainfall extremes, Nature'

This package contains the main codes, sample input data and main result files to reproduce the analysis and results presented in the article: “Ombadi et al. (2023), A warming-induced reduction in snow fraction amplifies rainfall extremes, Nature”. The folder consists of the following: (1) “Raw data”: a folder that contains sample input data which is used in some of the codes for demonstration purposes. It also contains data that was not pre-processed such as Elevation data; (2) “Results”: this folder contains files of the main results presented in the paper including: “Annual-Max-Series”, “Change-rainfall-extremes”, “Change-snow-fraction”, “Warming levels_By scenario_model_year” and “Masks”. Description of these folders is detailed in the "Readme.rtf" file; (3) Python jupyter notebooks (Extract_Annual Max Series (AMS).ipynb, Elevation-dependent amplification of rainfall extremes.ipynb, Sensitivity_to_global_warming.ipynb) demonstrate the main steps of analysis. Further description of those notebooks is provided in the "Readme.rtf" file; (4) R code for extreme value analysis (Extreme_Value_Analysis.R). The sample and pre-processed dataset in "Raw data" is obtained from publicly available repositories of CMIP6 and ERA5 datasets; see Methods for more detail. This research was supported by Office of Science, Office of Biological and Environmental Research of the US Department of Energy under contract no. DE-AC02-05CH11231 for the CASCADE Scientific Focus (funded by the Regional and Global Model Analysis Program area within the Earth and Environmental Systems Modeling Program) and the iNAIADS Early Career Research Project (funded by the Environmental Systems Science program).

54 ENVIRONMENTAL SCIENCES↗