Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Mcl-1-Bim complexes accommodate surprising point mutations via minor structural changes

Mcl-1 is an antiapoptotic Bcl-2-family protein that protects cells against death. Structures of Mcl-1, and of other anti-apoptotic Bcl-2 proteins, reveal a surface groove into which the {alpha}-helical BH3 regions of certain proapoptotic proteins can bind. Despite high overall structural conservation, differences in this groove afford binding specificity that is important for the mechanism of Bcl-2 family function. We report the crystal structure of human Mcl-1 bound to a BH3 peptide derived from human Bim and the structures for three complexes that accommodate large physicochemical changes at conserved Bim sites. The mutations had surprisingly modest effects on complex stability, and the structures show that Mcl-1 can undergo small changes to accommodate the mutant ligands. For example, a shift in a leucine side chain fills a hole left by an isoleucine-to-alanine mutation at the first hydrophobic buried position of Bim BH3. Larger changes are also observed, with shifting of helix {alpha}3 accommodating an isoleucine-to-tyrosine mutation at this same position. We surveyed the variation in available Mcl-1 and Bcl-x{sub L} structures and observed moderate flexibility that is likely critical for facilitating interactions of diverse BH3-only proteins with Mcl-1. With the antiapoptotic Bcl-2 family members attracting significant attention as therapeutic targets, these structures contribute to our growing understanding of how specificity is achieved and can help to guide the design of novel inhibitors that target Mcl-1.

36 MATERIALS SCIENCE↗

Conserved Binding Mode of Human [beta subscript 2] Adrenergic Receptor Inverse Agonists and Antagonist Revealed by X-ray Crystallography

G protein-coupled receptors (GPCRs) represent a large fraction of current pharmaceutical targets, and of the GPCRs, the {beta}{sub 2} adrenergic receptor ({beta}{sub 2}AR) is one of the most extensively studied. Previously, the X-ray crystal structure of {beta}{sub 2}AR has been determined in complex with two partial inverse agonists, but the global impact of additional ligands on the structure or local impacts on the binding site are not well-understood. To assess the extent of such ligand-induced conformational differences, we determined the crystal structures of a previously described engineered {beta}{sub 2}AR construct in complex with two inverse agonists: ICI 118,551 (2.8 {angstrom}), a recently described compound (2.8 {angstrom}) (Kolb et al, 2009), and the antagonist alprenolol (3.1 {angstrom}). The structures show the same overall fold observed for the previous {beta}{sub 2}AR structures and demonstrate that the ligand binding site can accommodate compounds of different chemical and pharmacological properties with only minor local structural rearrangements. All three compounds contain a hydroxy-amine motif that establishes a conserved hydrogen bond network with the receptor and chemically diverse aromatic moieties that form distinct interactions with {beta}{sub 2}AR. Furthermore, receptor ligand cross-docking experiments revealed that a single {beta}{sub 2}AR complex can be suitable for docking of a range of antagonists and inverse agonists but also indicate that additional ligand-receptor structures may be useful to further improve performance for in-silico docking or lead-optimization in drug design.

08 HYDROGEN↗

Design of Thomson scattering diagnostic system on J-TEXT

An infrared multi-channel Thomson scattering diagnostic system is designed from the viewpoint of development of the proposed system on the Joint Texas Experimental Tokamak (J-TEXT). A 3 J/50 Hz Nd:YAG laser, which is injected vertically into plasma in the direction from top to bottom, serves as the power source of the system. The scattering light is then collected horizontally and is transmitted to an interference-filter avalanche photodiode based polychromater for spectrum analysis. The system covers the half plasma cross section, providing 14 spatial points with 2 cm resolution. The proposed system can thus satisfy the requirements of the J-TEXT at present and in the near future. A detailed description of the system design is presented in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanism of Actin Filament Bundling by Fascin

Fascin is the main actin filament bundling protein in filopodia. Because of the important role filopodia play in cell migration, fascin is emerging as a major target for cancer drug discovery. However, an understanding of the mechanism of bundle formation by fascin is critically lacking. Fascin consists of four {beta}-trefoil domains. Here, we show that fascin contains two major actin-binding sites, coinciding with regions of high sequence conservation in {beta}-trefoil domains 1 and 3. The site in {beta}-trefoil-1 is located near the binding site of the fascin inhibitor macroketone and comprises residue Ser-39, whose phosphorylation by protein kinase C down-regulates actin bundling and formation of filopodia. The site in {beta}-trefoil-3 is related by pseudo-2-fold symmetry to that in {beta}-trefoil-1. The two sites are {approx}5 nm apart, resulting in a distance between actin filaments in the bundle of {approx}8.1 nm. Residue mutations in both sites disrupt bundle formation in vitro as assessed by co-sedimentation with actin and electron microscopy and severely impair formation of filopodia in cells as determined by rescue experiments in fascin-depleted cells. Mutations of other areas of the fascin surface also affect actin bundling and formation of filopodia albeit to a lesser extent, suggesting that, in addition to the two major actin-binding sites, fascin makes secondary contacts with other filaments in the bundle. In a high resolution crystal structure of fascin, molecules of glycerol and polyethylene glycol are bound in pockets located within the two major actin-binding sites. These molecules could guide the rational design of new anticancer fascin inhibitors.

59 BASIC BIOLOGICAL SCIENCES↗

Morphological evolution of Ag2Te precipitates in thermoelectric PbTe.

The precipitation of Ag{sub 2}Te in a PbTe matrix is investigated using electron microscopy and atom probe tomography. We observe the formation of oriented nanoscale Ag{sub 2}Te precipitates in PbTe. These precipitates initially form as coherent spherical nanoparticles and evolve into flattened semi-coherent disks during coarsening. This change in morphology is consistent with equilibrium shape theory for coherently strained precipitates. Upon annealing at elevated temperatures these precipitates eventually revert to an equiaxed morphology. We suggest this shape change occurs once the precipitates grow beyond a critical size, making it favorable to relieve the elastic coherency strains by forming interfacial misfit dislocations. These investigations of the shape and coherency of Ag{sub 2}Te precipitates in PbTe should prove useful in the design of nanostructured thermoelectric materials.

36 MATERIALS SCIENCE↗

Deformation of multilayer flexible electronics subjected to torque

Flexibility is one of remarkable characteristics of flexible electronics. Therefore, the analysis of flexible electronics deformation caused by external torques will help its design. In this work, analytical derivation is conducted for flexible electronics treated as multilayer structures. In experiments, an electric motor under computer control exerts a torque to generate torsion, whose twist angles are obtained by using both optical encoder measurement and theoretical calculation. Comparisons are made between experimental and theoretical results for bare PEN (polyethylene naphthalate) substrates of different sizes, multilayer PET (polyethylene terephthalate) substrates, and ITO (indium tin oxide)-coated PET substrates. Finally, a laser displacement sensor is used to measure the out-of-plane deformation for validating the proposed theoretical model.

36 MATERIALS SCIENCE↗

Quarter 2 Research Performance Progress Report (RPPR) - DOE Solar Program

Creep-fatigue deformation is an important consideration for a thermal receiver of a gas phase (GP) Concentrating Solar Power (CSP) system due to the constant static stress or pressure, diurnal cycling, and elevated service temperatures required for efficient operation. An accurate description of the creep-fatigue behavior, not available for five of the six candidate materials, is important for assessment of preliminary designs. This project will provide a detailed analysis of the creep-fatigue behavior and damage accumulation of a candidate structural material for a CSP solar thermal receiver to address a critical knowledge barrier for receiver design in the GP pathway concept identified in the CSP Gen3 Demonstration Roadmap. This effort includes the development of rules for the design of solar receiver components against high temperature creep-fatigue and ratcheting failure modes. The ASME Code rules for high temperature nuclear components will form the basis of the method but adjustments will be made to reflect the generally shorter, diurnal operating cycles of thermal receivers and the relative consequences of failure, comparing nuclear to solar components. This is report covers the second quarter's work, which addressed outstanding questions on alloy selection for Quarter 1, and began laying the ground work for mechanical testing.

14 SOLAR ENERGY↗

Feasibility analyses for HEU to LEU fuel conversion of the LAUE Langivin Institute (ILL) High Flux Reactor (RHF).

The High Flux Reactor (RHF) of the Laue Langevin Institute (ILL) based in Grenoble, France is a research reactor designed primarily for neutron beam experiments for fundamental science. It delivers one of the most intense neutron fluxes worldwide, with an unperturbed thermal neutron flux of 1.5 x 10{sup 15} n/cm{sup 2}/s in its reflector. The reactor has been conceived to operate at a nuclear power of 57 MW but currently operates at 52 MW. The reactor currently uses a Highly Enriched Uranium (HEU) fuel. In the framework of its non-proliferation policies, the international community presently aims to minimize the amount of nuclear material available that could be used for nuclear weapons. In this geopolitical context, most worldwide research and test reactors have already started a program of conversion to the use of Low Enriched Uranium (LEU) fuel. A new type of LEU fuel based on a mixture of uranium and molybdenum (UMo) is expected to allow the conversion of compact high performance reactors like the RHF. This report presents the results of reactor design, performance and steady state safety analyses for conversion of the RHF from the use of HEU fuel to the use of UMo LEU fuel. The objective of this work was to show that is feasible, under a set of manufacturing assumptions, to design a new RHF fuel element that could safely replace the HEU element currently used. The new proposed design has been developed to maximize performance, minimize changes and preserve strong safety margins. Neutronics and thermal-hydraulics models of the RHF have been developed and qualified by benchmark against experiments and/or against other codes and models. The models developed were then used to evaluate the RHF performance if LEU UMo were to replace the current HEU fuel 'meat' without any geometric change to the fuel plates. Results of these direct replacement analyses have shown a significant degradation of the RHF performance, in terms of both neutron flux and cycle length. Consequently, ANL and ILL have collaborated to investigate alternative designs. A promising candidate design has been selected and studied, increasing the total amount of fuel without changing the external plate dimensions by relocating the burnable poison. In this way, changes required in the fuel element are reasonably small. With this new design, neutronics analyses have shown that performance could be maintained at a high level: 2 day decrease of cycle length (to 47.5 days at 58.3 MW) and 1-2% decrease of brightness in the cold and hot sources in comparison to the current typical operation. In addition, studies have shown that the thermal-hydraulic and shutdown margins for the proposed LEU design would satisfy technical specifications.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Active-Site-Accessible, Porphyrinic Metal;#8722;Organic Framework Materials

On account of their structural similarity to cofactors found in many metallo-enzymes, metalloporphyrins are obvious potential building blocks for catalytically active, metal-organic framework (MOF) materials. While numerous porphyrin-based MOFs have already been described, versions featuring highly accessible active sites and permanent microporosity are remarkably scarce. Indeed, of the more than 70 previously reported porphyrinic MOFs, only one has been shown to be both permanently microporous and contain internally accessible active sites for chemical catalysis. Attempts to generalize the design approach used in this single successful case have failed. Reported here, however, is the synthesis of an extended family of MOFs that directly incorporate a variety of metalloporphyrins (specifically Al{sup 3+}, Zn{sup 2+}, Pd{sup 2+}, Mn{sup 3+}, and Fe{sup 3+} complexes). These robust porphyrinic materials (RPMs) feature large channels and readily accessible active sites. As an illustrative example, one of the manganese-containing RPMs is shown to be catalytically competent for the oxidation of alkenes and alkanes.

36 MATERIALS SCIENCE↗

Photonic crystal slab quantum cascade detector

In this Letter, we demonstrate the design, fabrication, and characterization of a photonic crystal slab quantum cascade detector (PCS-QCD). By employing a specifically designed resonant cavity, the performance of the photodetector is improved in three distinct ways. The PCS makes the QCD sensitive to surface normal incident light. It resonantly enhances the photon lifetime inside the active zone, thus increasing the photocurrent significantly. And, the construction form of the device inherently decreases the noise. Finally, we compare the characteristics of the PCS-QCD to a PCS - quantum well infrared photodetector and outline the advantages for certain fields of applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Miniature coils for producing pulsed inplane magnetic fields for nanospintronics

Nanospintronic and related research often requires the application of quickly rising magnetic field pulses in the plane of the studied planar structure. We have designed and fabricated sub-millimeter-sized coils capable of delivering pulses of the magnetic field up to ∼500 Oe in the plane of the sample with the rise time of the order of 10 ns. The placement of the sample above the coil allows for easy access to its surface with manipulators or light beams for, e.g., Kerr microscopy. We use the fabricated coil to drive magnetic domain walls in 1 μm wide permalloy wires and measure magnetic domain wall velocity as a function of the applied magnetic field.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrating science for water security governance

Hydrological extremes are intensifying globally, increasing the complexity of decisions required to ensure water security. Advances in hydrological science, modeling, and data systems have expanded the technical frontier of water research, yet uptake of scientific insights in policy and management decisions remains limited. This persistent science–policy gap is not primarily a failure of knowledge generation or robustness, but an institutional challenge shaped by how scientific and governance systems are organized, coordinated, and connected to support the effective use of scientific knowledge. These challenges are particularly pronounced in multi-level and transboundary water governance, where decisions span jurisdictions and require coordination across institutional and political boundaries. We synthesize research at the science–policy interface and evidence from water security initiatives to show how institutional arrangements, scientific tool development, and research practices enable or constrain the sustained use of scientific knowledge in water-security governance processes. Building on these insights, we develop ‘shared decision infrastructure’ as a framing to describe how scientific knowledge is embedded within the institutional, relational, and procedural arrangements that connect science to decision-making processes over time. We translate this framing into a practical intervention roadmap centered on institutional design, tool translation, sustained co-production, and outcome-oriented evaluation to support the integration of science into ongoing governance processes. By positioning science as shared decision infrastructure, the roadmap clarifies how researchers can design scientific efforts that support more coordinated, accountable, and adaptive water security decisions amid deepening uncertainty.

M whitney, Kristen [NASA Goddard Space Flight Cent↗

Divergence study and emittance measurements for the electron beam emitted from a diamond pyramid

This paper reports the results of a divergence study and emittance measurements for an electron beam emitted from a single diamond pyramid in a sparse diamond field-emitter array (DFEA) cathode. DFEA cathodes are arrays of micrometer scale diamond pyramids with nanometer scale tips. A single diamond pyramid produces currents as high as 10 μA from a small surface area. DFEA cathodes are expected to be a good beam source for compact dielectric laser accelerators. For the electron beam divergence experiment, we have designed and assembled a test stand consisting of a DFEA cathode, a mesh anode, and a screen. We measured current and the size of the beam on the screen as functions of the distance between the cathode and the anode, the size of a pyramid’s base, and applied voltage on the cathode. In order to perform beam emittance measurements, we designed and fabricated a magnetic lens to be placed between the mesh and the screen. By measuring the size of the beam for different distances between the lens and the screen, we estimate the beam’s emittance. Here, we also simulated the electron beam dynamics with Computer Simulation Technology Studio and General Particle Tracer codes. Experimentally measured divergence angles and normalized transverse emittance show good agreement with simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding Reliability Trade-Offs in 1T-nC and 2T-nC FeRAM Designs

Ferroelectric random access memory (FeRAM) is a promising candidate for energy-efficient nonvolatile memory, particularly for logic-in-memory and compute-in-memory (CIM) applications. Among the available cell architectures, One-Transistor–n-Capacitor (1T-nC) and two-transistor–n-capacitor (2T-nC) FeRAMs each offer distinct trade-offs in density, scalability, and reliability. In this work, we present a comparative study of these two architectures under both dimensional scaling ( XY/Z shrinkage) and vertical integration (increasing stacked capacitors per cell). Using technology computer-aided design (TCAD) and circuit-level simulations, we analyze how scaling impacts ferroelectric capacitance, parasitic coupling, and floating-node (FN) dynamics, which together dictate sense margin (SM) and read stability. A key mitigation strategy—floating unselected capacitors—is applied to both architectures, effectively decoupling the SM from the number of stacked capacitors and enabling tractable analysis across scaling regimes. Results show that 1T-nC suffers more from charge sharing with the bitline (BL), while 2T-nC benefits from transistor isolation and stronger low-voltage sensing at the cost of increased area. By systematically evaluating these behaviors across scaling directions, this work establishes the reliability trade-offs of 1T-nC and 2T-nC cells and provides design guidelines for high-density, vertically integrated FeRAM systems.

1T-nC↗

Juvenile Salmon Acoustic Telemetry System Transmitter Downsize Assessment

At the request of the U.S. Army Corps of Engineers, Portland District, researchers from Pacific Northwest National Laboratory investigated the use of an application-specific integrated circuit (ASIC) to reduce the weight and volume of Juvenile Salmon Acoustic Telemetry System (JSATS) transmitters while retaining current functionality. Review of the design of current JSATS transmitters identified components that could be replaced by an ASIC while retaining the function of the current transmitter and offering opportunities to extend function if desired. ASIC design alternatives were identified that could meet transmitter weight and volume targets of 200 mg and 100 mm3. If alternatives to the cylindrical batteries used in current JSATS transmitters can be identified, it could be possible to implant ASIC-based JSATS transmitters by injection rather than surgery. Using criteria for the size of fish suitable for surgical implantation of current JSATS transmitters, it was concluded that fish as small as 70 mm in length could be implanted with an ASIC-based transmitter, particularly if implantation by injection became feasible.

47 OTHER INSTRUMENTATION↗

Feasibility Study of Continuous Casting of Steel Billets in Twin-Belt Caster

Integrated casting and rolling in a series production line is well established for the non-ferrous metals through the use of twin-belt casting technology. However, this twin-belt casting with high mass flow is not yet commercialized in the continuous production of steel alloys. A novel steel casting for the in-line rolling (named LUUP method) is presented and one main focus of this work is to design a casting machine: twin-belt caster. Influence of mass flow rate and dimensional ratio on the solidification, compensation, and total process length is addressed. A gap-dependent belt and dam block side heat transfer is modeled. The admissible casting speed due to the limitations of caster length and shell strength is addressed. The total process length only depends on the mass flow rate. A 2D traveling slice numerical model is presented with realistic boundary conditions for the entire process starting from the meniscus to roll mill entry.

36 MATERIALS SCIENCE↗

High resolution hard x-ray microscope on a second generation synchrotron source

A full-field, transmission x-ray microscope (TXM) operating in the energy range of 7-11 keV has been installed at the U7A beamline at the National Synchrotron Radiation Laboratory, a second generation synchrotron source operating at 0.8 GeV. Although the photon flux at sample position in the operating energy range is significantly low due to its relatively large emittance, the TXM can get high quality x-ray images with a spatial resolution down to 50 nm with acceptable exposure time. This TXM operates in either absorption or Zernike phase contrast mode with similar resolution. This TXM is a powerful analytical tool for a wide range of scientific areas, especially studies on nanoscale phenomena and structural imaging in biology, materials science, and environmental science. We present here the property of the x-ray source, beamline design, and the operation and key optical components of the x-ray TXM. Plans to improve the throughput of the TXM will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A novel biomimetic approach to the design of high-performance ceramic/metal composites

The prospect of extending natural biological design to develop new synthetic ceramic-metal composite materials is examined. Using ice-templating of ceramic suspensions and subsequent metal infiltration, we demonstrate that the concept of ordered hierarchical design can be applied to create fine-scale laminated ceramic-metal (bulk) composites that are inexpensive, lightweight and display exceptional damage-tolerance properties. Specifically, Al{sub 2}O{sub 3}/Al-Si laminates with ceramic contents up to approximately 40 vol% and with lamellae thicknesses down to 10 {micro}m were processed and characterized. These structures achieve an excellent fracture toughness of 40 MPa{radical}m at a tensile strength of approximately 300 MPa. Salient toughening mechanisms are described together with further toughening strategies.

36 MATERIALS SCIENCE↗