Search NASA⌕ Search

SEARCH · Search NASA

Results for “Error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Continuous quantum error correction through local operations

We propose local strategies to protect global quantum information. The protocols, which are quantum error-correcting codes for dissipative systems, are based on environment measurements, direct feedback control, and simple encoding of the logical qubits into physical qutrits whose decaying transitions are indistinguishable and equally probable. The simple addition of one extra level in the description of the subsystems allows for local actions to fully and deterministically protect global resources such as entanglement. We present codes for both quantum jump and quantum state diffusion measurement strategies and test them against several sources of inefficiency. The use of qutrits in information protocols suggests further characterization of qutrit-qutrit disentanglement dynamics, which we also give together with simple local environment measurement schemes able to prevent distillability sudden death and even enhance entanglement in situations in which our feedback error correction is not possible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Relation between minimum-error discrimination and optimum unambiguous discrimination

In this paper, we investigate the relationship between the minimum-error probability Q{sub E} of ambiguous discrimination and the optimal inconclusive probability Q{sub U} of unambiguous discrimination. It is known that for discriminating two states, the inequality Q{sub U{>=}}2Q{sub E} has been proved in the literature. The main technical results are as follows: (1) We show that, for discriminating more than two states, Q{sub U{>=}}2Q{sub E} may not hold again, but the infimum of Q{sub U}/Q{sub E} is 1, and there is no supremum of Q{sub U}/Q{sub E}, which implies that the failure probabilities of the two schemes for discriminating some states may be narrowly or widely gapped. (2) We derive two concrete formulas of the minimum-error probability Q{sub E} and the optimal inconclusive probability Q{sub U}, respectively, for ambiguous discrimination and unambiguous discrimination among arbitrary m simultaneously diagonalizable mixed quantum states with given prior probabilities. In addition, we show that Q{sub E} and Q{sub U} satisfy the relationship that Q{sub U{>=}}(m/m-1)Q{sub E}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Minimum-error discrimination of entangled quantum states

Strategies to optimally discriminate between quantum states are critical in quantum technologies. We present an experimental demonstration of minimum-error discrimination between entangled states, encoded in the polarization of pairs of photons. Although the optimal measurement involves projection onto entangled states, we use a result of J. Walgate et al. [Phys. Rev. Lett. 85, 4972 (2000)] to design an optical implementation employing only local polarization measurements and feed-forward, which performs at the Helstrom bound. Our scheme can achieve perfect discrimination of orthogonal states and minimum-error discrimination of nonorthogonal states. Our experimental results show a definite advantage over schemes not using feed-forward.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Local non-Calderbank-Shor-Steane quantum error-correcting code on a three-dimensional lattice

We present a family of non-Calderbank-Shor-Steane quantum error-correcting code consisting of geometrically local stabilizer generators on a 3D lattice. We study the Hamiltonian constructed from ferromagnetic interaction of overcomplete set of local stabilizer generators. The degenerate ground state of the system is characterized by a quantum error-correcting code whose number of encoded qubits are equal to the second Betti number of the manifold. These models (i) have solely local interactions; (ii) admit a strong-weak duality relation with an Ising model on a dual lattice; (iii) have topological order in the ground state, some of which survive at finite temperature; and (iv) behave as classical memory at finite temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-qubit-gate error below 10{sup -4} in a trapped ion

With a {sup 9}Be{sup +} trapped-ion hyperfine-state qubit, we demonstrate an error probability per randomized single-qubit gate of 2.0(2)x10{sup -5}, below the threshold estimate of 10{sup -4} commonly considered sufficient for fault-tolerant quantum computing. The {sup 9}Be{sup +} ion is trapped above a microfabricated surface-electrode ion trap and is manipulated with microwaves applied to a trap electrode. The achievement of low single-qubit-gate errors is an essential step toward the construction of a scalable quantum computer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quadratic dynamical decoupling: Universality proof and error analysis

We prove the universality of the generalized QDD{sub N{sub 1N{sub 2}}} (quadratic dynamical decoupling) pulse sequence for near-optimal suppression of general single-qubit decoherence. Earlier work showed numerically that this dynamical decoupling sequence, which consists of an inner Uhrig DD (UDD) and outer UDD sequence using N{sub 1} and N{sub 2} pulses, respectively, can eliminate decoherence to O(T{sup N}) using O(N{sup 2}) unequally spaced ''ideal'' (zero-width) pulses, where T is the total evolution time and N=N{sub 1}=N{sub 2}. A proof of the universality of QDD has been given for even N{sub 1}. Here we give a general universality proof of QDD for arbitrary N{sub 1} and N{sub 2}. As in earlier proofs, our result holds for arbitrary bounded environments. Furthermore, we explore the single-axis (polarization) error suppression abilities of the inner and outer UDD sequences. We analyze both the single-axis QDD performance and how the overall performance of QDD depends on the single-axis errors. We identify various performance effects related to the parities and relative magnitudes of N{sub 1} and N{sub 2}. We prove that using QDD{sub N{sub 1N{sub 2}}} decoherence can always be eliminated to O(T{sup min{l_brace}N{sub 1},N{sub 2}{r_brace}}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Environment-assisted error correction of single-qubit phase damping

Open quantum system dynamics of random unitary type may in principle be fully undone. Closely following the scheme of environment-assisted error correction proposed by Gregoratti and Werner [J. Mod. Opt. 50, 915 (2003)], we explicitly carry out all steps needed to invert a phase-damping error on a single qubit. Furthermore, we extend the scheme to a mixed-state environment. Surprisingly, we find cases for which the uncorrected state is closer to the desired state than any of the corrected ones.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Postfabrication Phase Error Correction of Silicon Photonic Circuits by Single Femtosecond Laser Pulses

Phase errors caused by fabrication variations in silicon photonic integrated circuits are an important problem, which negatively impacts device yield and performance. This study reports our recent progress in the development of a method for permanent, postfabrication phase error correction of silicon photonic circuits based on femtosecond laser irradiation. Using beam shaping technique, we achieve a 14-fold enhancement in the phase tuning resolution of the method with a Gaussian-shaped beam compared to a top-hat beam. The large improvement in the tuning resolution makes the femtosecond laser method potentially useful for very fine phase trimming of silicon photonic circuits. Finally, we also show that femtosecond laser pulses can directly modify silicon photonic devices through a SiO 2 cladding layer, making it the only permanent post-fabrication method that can tune silicon photonic circuits protected by an oxide cladding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FedCSpc: A Cross-Silo Federated Learning System With Error-Bounded Lossy Parameter Compression

Cross-Silo federated learning is widely used for scaling deep neural network (DNN) training over data silos from different locations worldwide while guaranteeing data privacy. Communication has been identified as the main bottleneck when training large-scale models due to large-volume model parameters and gradient transmission across public networks with limited bandwidth. Most previous works focus on gradient compression, while limited work tries to compress parameters that can not be ignored and extremely affect communication performance during the training. Here, to bridge this gap, we propose FedCSpc: an efficient cross-silo federated learning system with an XAI-driven adaptive parameter compression strategy for large-scale model training. Our work substantially differs from existing gradient compression techniques due to the distinct data features of gradient and parameter. The key contributions of this paper are fourfold. (1) Our designed FedCSpc proposes to compress the parameter during the training using the state-of-the-art error-bounded lossy compressor – SZ3. (2) We develop an adaptive compression error bound adjustment algorithm to guarantee the model accuracy effectively. (3) We exploit an efficient approach to utilize the idle CPU resources of clients to compress the parameters. (4) We perform a comprehensive evaluation with a wide range of models and benchmarks on a GPU cluster with 65 GPUs. Results show that FedCSpc can achieve the same model accuracy as FedAvg while reducing the data volume of parameters and gradients in communication by up to 7.39× and 288×, respectively. With 32 clients on a 4 Gb size model, FedCSpc significantly outperforms FedAvg in wall-clock time in the emulated WAN environment (at the bandwidth of 1 Gbps or lower without loss of generality).

SZ3↗

FedEFsz: Fair Cross-Silo Federated Learning System With Error-Bounded Lossy Compression

Cross-Silo federated learning systems have been identified as an efficient approach to scaling DNN training across geographically-distributed data silos to preserve the privacy of the training data. Communication efficiency and fairness are two major issues that need to be both satisfied when federated learning systems are deployed in practice. Simultaneously guaranteeing both of them, however, is exceptionally difficult because simply combining communication reduction and fairness optimization approaches often causes non-converged training or drastic accuracy degradation. Here, to bridge this gap, we propose FedEFsz. On the one hand, it integrates the state-of-the-art error-bounded lossy compressor SZ3 into cross-silo federated learning systems to significantly reduce communication traffic during the training. On the other hand, it achieves a high fairness (i.e., rather consistent model accuracy and performance across different clients) through a carefully designed heuristic algorithm that can tune the error-bound of SZ3 for different clients during the training. Extensive experimental results based on a GPU cluster with 65 GPU cards show that FedEFsz improves the fairness across different benchmarks by up to 60.88% and meanwhile reduces the communication traffic by up to 315×.

Cross-Silo Federated Learning Systems↗

Theoretical analysis on the measurement errors of local 2D DIC: Part I temporal and spatial uncertainty quantification of displacement measurements

This study presents a theoretical uncertainty quantification of displacement measurements by subset-based 2D-digital image correlation. A generalized solution to estimate the random error of displacement measurement is presented. The obtained solution suggests that the random error of displacement measurements is determined by the image noise, the summation of the intensity gradient in a subset, the subpixel part of displacement, and the interpolation scheme. The proposed method is validated with virtual digital image correlation tests.

2D-DIC↗

Model Form Error Correction for a Black-Box Thermal Battery Heat Transfer Simulation

Thermal batteries are crucial for supplying power to high-consequence engineering applications such as rockets. Computational simulations have been developed to predict thermal battery behavior, but these simulations often suffer from modeling errors, including model form uncertainty. Addressing this uncertainty can be achieved by quantifying either the model discrepancy in the output or the model form error (MFE) in the governing equation. MFE is particularly valuable as it can be better extrapolated beyond observed outputs, which is essential for predictions involving changes in external system loading, system configuration and geometry, or output quantities. This paper employs a state estimation approach to estimate MFE using experimental data and then utilizes machine learning (ML) to model its relationship with state variables. A nonintrusive technique is used to estimate MFE in a black-box thermal battery heat transfer simulation. The trained machine learning model for MFE is then applied to correct simulation predictions under extrapolated initial conditions and battery configurations. In conclusion, the methodology's performance is evaluated using additional experimental data, demonstrating its effectiveness in improving prediction accuracy.

Batteries↗

A two-dimensional matrix correction for off-axis portal dose prediction errors

Purpose: This study presents a follow-up to a modified calibration procedure for portal dosimetry published by Bailey et al. ['An effective correction algorithm for off-axis portal dosimetry errors,' Med. Phys. 36, 4089-4094 (2009)]. A commercial portal dose prediction system exhibits disagreement of up to 15% (calibrated units) between measured and predicted images as off-axis distance increases. The previous modified calibration procedure accounts for these off-axis effects in most regions of the detecting surface, but is limited by the simplistic assumption of radial symmetry. Methods: We find that a two-dimensional (2D) matrix correction, applied to each calibrated image, accounts for off-axis prediction errors in all regions of the detecting surface, including those still problematic after the radial correction is performed. The correction matrix is calculated by quantitative comparison of predicted and measured images that span the entire detecting surface. The correction matrix was verified for dose-linearity, and its effectiveness was verified on a number of test fields. The 2D correction was employed to retrospectively examine 22 off-axis, asymmetric electronic-compensation breast fields, five intensity-modulated brain fields (moderate-high modulation) manipulated for far off-axis delivery, and 29 intensity-modulated clinical fields of varying complexity in the central portion of the detecting surface. Results: Employing the matrix correction to the off-axis test fields and clinical fields, predicted vs measured portal dose agreement improves by up to 15%, producing up to 10% better agreement than the radial correction in some areas of the detecting surface. Gamma evaluation analyses (3 mm, 3% global, 10% dose threshold) of predicted vs measured portal dose images demonstrate pass rate improvement of up to 75% with the matrix correction, producing pass rates that are up to 30% higher than those resulting from the radial correction technique alone. As in the 1D correction case, the 2D algorithm leaves the portal dosimetry process virtually unchanged in the central portion of the detector, and thus these correction algorithms are not needed for centrally located fields of moderate size (at least, in the case of 6 MV beam energy).Conclusion: The 2D correction improves the portal dosimetry results for those fields for which the 1D correction proves insufficient, especially in the inplane, off-axis regions of the detector. This 2D correction neglects the relatively smaller discrepancies that may be caused by backscatter from nonuniform machine components downstream from the detecting layer.

60 APPLIED LIFE SCIENCES↗

SU-E-T-418: Explore the Sensitive of the Planar Quality Assurance to the MLC Error with Different Beam Complexity in Intensity-Modulate Radiation Therapy

Purpose: The purpose of this study is to investigate the sensitivity of the planar quality assurance to MLC errors with different beam complexities in intensity-modulate radiation therapy. Methods: sixteen patients’ planar quality assurance (QA) plans in our institution were enrolled in this study, including 10 dynamic MLC (DMLC) IMRT plans measured by Portal Dosimetry and 6 static MLC (SMLC) IMRT plans measured by Mapcheck. The gamma pass rate was calculated using vender’s software. The field numbers were 74 and 40 for DMLC and SMLC, respectively. A random error was generated and introduced to these fields. The modified gamma pass rate was calculated by comparing the original measured fluence and modified fields’ fluence. A decreasing gamma pass rate was acquired using the original gamma pass rate minus the modified gamma pass rate. Eight complexity scores were calculated in MATLAB based on the fluence and MLC sequence of these fields. The complexity scores include fractal dimension, monitor unit of field, modulation index, fluence map complexity, weighted average of field area, weighted average of field perimeter, and small aperture ratio ( <5cm{sup 2} and <50cm{sup 2}). The Spearman’s rank correlation coefficient was implemented to analyze the correlation between these scores and decreasing gamma rate. Results: The relation between the decreasing gamma pass rate and field complexity was insignificant for most complexity scores. The most significant complexity score was fluence map complexity for SMLC, which have ρ =0.4274 (p-value=0.0063). For DMLC, the most significant complex score was fractal dimension, which have ρ=−0.3068 (p-value=0.0081). Conclusions: According to the primarily Result of this study, the sensitivity gamma pass rate was not strongly relate to the field complexity.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-04: Evaluation of the Tumor Registration Error in Biopsy Procedures Performed Under Real Time PET/CT Guidance

Purpose: PET/CT guidance is used for biopsies of metabolically active lesions, which are not well seen on CT alone or to target the metabolically active tissue in tumor ablations. It has also been shown that PET/CT guided biopsies provide an opportunity to verify the location of the lesion border at the place of needle insertion. However the error in needle placement with respect to the metabolically active region may be affected by motion between the PET/CT scan performed at the start of the procedure and the CT scan performed with the needle in place and this error has not been previously quantified. Methods: Specimens from 31 PET/CT guided biopsies were investigated and correlated to the intraoperative PET scan under an IRB approved HIPAA compliant protocol. For 4 of the cases in which larger motion was suspected a second PET scan was obtained with the needle in place. The CT and the PET images obtained before and after the needle insertion were used to calculate the displacement of the voxels along the needle path. CTpost was registered to CTpre using a free form deformable registration and then fused with PETpre. The shifts between the PET image contours (42% of SUVmax) for PETpre and PETpost were obtained at the needle position. Results: For these extreme cases the displacement of the CT voxels along the needle path ranged from 2.9 to 8 mm with a mean of 5 mm. The shift of the PET image segmentation contours (42% of SUVmax) at the needle position ranged from 2.3 to 7 mm between the two scans. Conclusion: Evaluation of the mis-registration between the CT with the needle in place and the pre-biopsy PET can be obtained using deformable registration of the respective CT scans and can be used to indicate the need of a second PET in real-time. This work is supported in part by a grant from Biospace Lab, S.A.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-09: Sensitivity of Plan Re-Optimization to Errors in Deformable Image Registration in Online Adaptive Image-Guided Radiation Therapy

Purpose: Online adaptive therapy (ART) relies on auto-contouring using deformable image registration (DIR). DIR’s inherent uncertainties require user intervention and manual edits while the patient is on the table. We investigated the dosimetric impact of DIR errors on the quality of re-optimized plans, and used the findings to establish regions for focusing manual edits to where DIR errors can Result in clinically relevant dose differences. Methods: Our clinical implementation of online adaptive MR-IGRT involves using DIR to transfer contours from CT to daily MR, followed by a physicians’ edits. The plan is then re-optimized to meet the organs at risk (OARs) constraints. Re-optimized abdomen and pelvis plans generated based on physician edited OARs were selected as the baseline for evaluation. Plans were then re-optimized on auto-deformed contours with manual edits limited to pre-defined uniform rings (0 to 5cm) around the PTV. A 0cm ring indicates that the auto-deformed OARs were used without editing. The magnitude of the variations caused by the non-deterministic optimizer was quantified by repeat re-optimizations on the same geometry to determine the mean and standard deviation (STD). For each re-optimized plan, various volumetric parameters for the PTV, the OARs were extracted along with DVH and isodose evaluation. A plan was deemed acceptable if the variation from the baseline plan was within one STD. Results: Initial results show that for abdomen and pancreas cases, a minimum of 5cm margin around the PTV is required for contour corrections, while for pelvic and liver cases a 2–3 cm margin is sufficient. Conclusion: Focusing manual contour edits to regions of dosimetric relevance can reduce contouring time in the online ART process while maintaining a clinically comparable plan. Future work will further refine the contouring region by evaluating the path along the beams, dose gradients near the target and OAR dose metrics.

60 APPLIED LIFE SCIENCES↗

SU-F-J-131: Reproducibility of Positioning Error Due to Temporarily Indwelled Urethral Catheter for Urethra-Sparing Prostate IMRT

Purpose: The purpose of this study was to prospectively assess the reproducibility of positioning errors due to temporarily indwelled catheter in urethra-sparing image-guided (IG) IMRT. Methods: Ten patients received urethra-sparing prostate IG-IMRT with implanted fiducials. After the first CT scan was performed in supine position, 6-Fr catheter was indwelled into urethra, and the second CT images were taken for planning. While the PTV received 80 Gy, 5% dose reduction was applied for the urethral PRV along the catheter. Additional CT scans were also performed at 5th and 30th fraction. Positions of interests (POIs) were set on posterior edge of prostate at beam isocenter level (POI1) and cranial and caudal edge of prostatic urethra on the post-indwelled CT images. POIs were copied into the pre-indwelled, 5th and 30th fraction’s CT images after fiducial matching on these CT images. The deviation of each POI between pre- and post-indwelled CT and the reproducibility of prostate displacement due to catheter were evaluated. Results: The deviation of POI1 caused by the indwelled catheter to the directions of RL/AP/SI (mm) was 0.20±0.27/−0.64±2.43/1.02±2.31, respectively, and the absolute distances (mm) were 3.15±1.41. The deviation tends to be larger if closer to the caudal edge of prostate. Compared with the pre-indwelled CT scan, a median displacement of all POIs (mm) were 0.3±0.2/2.2±1.1/2.0±2.6 in the post-indwelled, 0.4±0.4/3.4±2.1/2.3±2.6 in 5th, and 0.5±0.5/1.7±2.2/1.9±3.1 in 30th fraction’s CT scan with a similar data distribution. There were 6 patients with 5-mm-over displacement in AP and/or CC directions. Conclusion: Reproducibility of positioning errors due to temporarily indwelling catheter was observed. Especially in case of patients with unusually large shifts by indwelling catheter at the planning process, treatment planning should be performed by using the pre-indwelled CT images with transferred contour of the urethra identified by post-indwelled CT images.

60 APPLIED LIFE SCIENCES↗

Physically based correction of systematic errors of Rotating Shadowband Irradiometers

Accurate measurements of direct normal, diffuse horizontal and global horizontal irradiance (DNI, DHI and GHI) are needed for meteorological studies and are essential for the solar resource assessment at potential solar power plant sites. Often, these potential sites are remote and hence require robust sensors that require minimal maintenance that are not affected strongly by soiling. Therefore, Rotating Shadowband Irradiometers (RSI) are widely used for resource assessment. To achieve the required accuracy, corrections for the raw values of RSIs depending on systematic temperature, incidence angle and spectral errors must be used, and a thorough calibration of the sensor head must be applied. The existing correction functions are derived from comparisons of RSIs to thermopile radiometers at selected sites and therefore empirical. Their accuracy is considered to be site dependent. In this work a new correction and calibration method is presented that removes the systematic errors using a physical approach. It is based on information of the sensor properties as well as measurements of its directional response, and incorporates the atmospheric conditions at the measurement site. In this case, no empiric relations obtained from a specific site are required. The method requires estimates of the current DHI and GHI spectra during each measurement of the RSI. Based on these spectra, a spectral correction, which includes a spectrum dependent temperature correction, can be made without employing empirical relationships. The new physical calibration and correction method is tested at three sites and reaches similar results compared to the empirical functions. This is already achieved with rudimentary estimations of the GHI and DHI spectra and we expect that these estimations can be improved in the future. The results indicate that the physical approach reduces the problematic location dependence of the current calibration and correction methods. The physical correction and calibration method show promise for a further improvement of the RSI accuracy.

47 OTHER INSTRUMENTATION↗