Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Improved first-principles equation-of-state table of deuterium for high-energy-density applications

Here, we present a first-principles equation-of-state (EOS) table of deuterium aimed at improving the previously established first-principles equation-of-state table (FPEOS). The EOS table presented here, referred to as iFPEOS, introduces (1) a universal density functional theory (DFT) treatment of all density and temperature conditions, (2) a fully consistent treatment of exchange-correlation (XC) thermal effects across the entire range of temperatures covered, and (3) quantum treatment of ions. Based on ab initio molecular dynamics driven by thermal density functional theory, iFPEOS includes density points in the range 1×10 –3 $\leqslant$ ρ $\leqslant$ 1.6×10 3 g/cm 3 and temperature points in the range 800 K $\leqslant$ T $\leqslant$ 256 MK, thus covering the challenging warm dense matter (WDM) regime. For an improved description of the electronic structure, iFPEOS employs an advanced free-energy XC density functional with explicit temperature dependence, which is at the metageneralized gradient approximation level of DFT. We use the latest orbital-free free-energy density functional for the high-temperature regime where it shows excellent agreement with standard Mermin-Kohn-Sham DFT. For quantum treatment of ions we use path-integral molecular dynamics in order to take into account nuclear quantum effects. Results are compared to other EOS models and most recent experimental measurements of deuterium properties such as the molecular-toatomic fluid transition, the principal and reshock Hugoniot, and sound speed. We find that iFPEOS provides an improved agreement with experimental data compared to other first-principles EOS models in the WDM regime for pressures up to 200 GPa and temperatures up to 60 000 K. For higher pressures and temperatures, however, iFPEOS is in agreement with other models in predicting lower compressibility and higher sound speed along the Hugoniot, compared to experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Achieving a Strongly Temperature-Dependent Casimir Effect

We propose a method of achieving large temperature T sensitivity in the Casimir force that involves measuring the stable separation between dielectric objects immersed in a fluid. We study the Casimir force between slabs and spheres using realistic material models, and find large >2 nm/K variations in their stable separations (hundreds of nanometers) near room temperature. In addition, we analyze the effects of Brownian motion on suspended objects, and show that the average separation is also sensitive to changes in T. Finally, this approach also leads to rich qualitative phenomena, such as irreversible transitions, from suspension to stiction, as T is varied.

36 MATERIALS SCIENCE↗

Nitric oxide molecular tagging velocimetry of a free-flight model in a reflected shock tunnel

Nitric oxide molecular tagging velocimetry (NO MTV) is used to characterize the wake behind a free-flight spherical model in the test section of a free-piston reflected shock tunnel using a burst-mode laser operated at 100 kHz. A novel (to our knowledge) multi-delay timing scheme was implemented to measure velocity in a varying collisional environment in the wake of the free-flight model. Four simultaneous velocity profiles were measured in the wake of the model from -600 to 3600 m/s for flow enthalpies of 10.3 and 12.0 MJ/kg. Finally, the measured velocity distributions show good agreement when compared to computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

Swept-Frequency Acoustic Interferometry (SFAI) and Related Technologies

Researchers at Los Alamos National Lab have developed acoustic technologies to accurately discern the characteristics of materials within closed containers non-invasively. SFAI and related technologies use high-frequency sound to characterize liquids, gasses, mixtures, emulsions, and other fluids inside pipes and containers. SFAI offers the potential to measure material characteristics and two-and three-phase flows within pipes including flow rates and water- and gas-volume fractions all with a small-footprint device. SFAI is an enabling component of a 2014 R&D 100 Award Winner.

36 MATERIALS SCIENCE↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗

A multi-site resting state fMRI study on the amplitude of low frequency fluctuations in schizophrenia

Background: This multi-site study compares resting state fMRI amplitude of low frequency fluctuations (ALFF) and fractional ALFF (fALFF) between patients with schizophrenia (SZ) and healthy controls (HC). Methods: Eyes-closed resting fMRI scans (5:38 min; n = 306, 146 SZ) were collected from 6 Siemens 3T scanners and one GE 3T scanner. Imaging data were pre-processed using an SPM pipeline. Power in the low frequency band (0.01–0.08 Hz) was calculated both for the original pre-processed data as well as for the pre-processed data after regressing out the six rigid-body motion parameters, mean white matter (WM) and cerebral spinal fluid (CSF) signals. Both original and regressed ALFF and fALFF measures were modeled with site, diagnosis, age, and diagnosis × age interactions. Results: Regressing out motion and non-gray matter signals significantly decreased fALFF throughout the brain as well as ALFF in the cortical edge, but significantly increased ALFF in subcortical regions. Regression had little effect on site, age, and diagnosis effects on ALFF, other than to reduce diagnosis effects in subcortical regions. There were significant effects of site across the brain in all the analyses, largely due to vendor differences. HC showed greater ALFF in the occipital, posterior parietal, and superior temporal lobe, while SZ showed smaller clusters of greater ALFF in the frontal and temporal/insular regions as well as in the caudate, putamen, and hippocampus. HC showed greater fALFF compared with SZ in all regions, though subcortical differences were only significant for original fALFF. Conclusions: SZ show greater eyes-closed resting state low frequency power in frontal cortex, and less power in posterior lobes than do HC; fALFF, however, is lower in SZ than HC throughout the cortex. These effects are robust to multi-site variability. Regressing out physiological noise signals significantly affects both total and fALFF measures, but does not affect the pattern of case/control differences.

59 BASIC BIOLOGICAL SCIENCES↗

Polycystic Liver Disease

A 77-year-old African American male presented with intermittent abdominal pain for one week. He denied nausea, vomiting, diarrhea, constipation, fevers, anorexia, or weight loss. He denied a family history of liver disease, recent travel, or history of intravenous drug abuse. His vital signs were normal. Labs revealed total bilirubin of 1.5 mg/dl, hypoalbuminaemia 3.0 gm/dl and prolonged prothrombin time of 14.8 sec. Computed Tomography of the abdomen and pelvis with contrast showed multiple hepatic cysts with the largest cyst occupying the right abdomen, measuring 20.6 cm (Panel A and). This cyst had predominantly fluid attenuation, but also contained several septations. The patient underwent laparoscopic fenestration of the large hepatic cyst with hepatic cyst wall biopsy. Pathology revealed blood without malignant cells. The patient tolerated the procedure well with improvement of his abdominal pain and normalization of his liver function tests and coagulation profile.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

aoscpcu1m (b1)

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC). The CPC is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aoscpcf (01)

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC). The CPC is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

aoscpc (a1)

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC). The CPC is part of the aerosol observing system (AOS).

54 ENVIRONMENTAL SCIENCES↗

ARM Aerial Facility (AAF) Water-based Condensation Particle Counter

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC).

54 ENVIRONMENTAL SCIENCES↗

An optical quality meter suitable for cryogenic liquids

Construction of instrument to measure ratio of liquid to gas of flowing transparent cryogenic fluid is described. Instrument consists of collimated light source and photoconductive cell. Operation of instrument is described and illustration of equipment is provided.

Hobart, H. F.↗

Theory of rheology

The structure of the modern theory of rheology is discussed to show the assumptions and limitations. Rheology is discussed as a branch of continuum mechanics to determine the relationships between stress, strain, and strain rate which will give a closer representation of lubricant properties than the Newtonian flow equation. Rheology is also investigated as a branch of chemical physics. Consideration is limited to those theories of nonpolymeric and polymeric fluids which can represent viscoelasticity in terms of identifiable and measureable molecular characteristics. The possibility that elastic liquids may rupture in shear and linear tension analogous to the failure of solids is proposed.

Hutton, J. F.↗

Skylab experiment M-092 - Results of the first manned mission

Blood pressure, heart rate, and percentage increase in leg volume were continuously recorded for the Inflight Lower Body Negative Pressure (LBNP) experiment conducted during the first manned Skylab mission. Data were collected over a 5-month preflight period as well as at approximately 3-day intervals throughout the mission. Individual variations in cardiovascular responses to LBNP during the preflight period continued to be demonstrated inflight, and measurements of the calf showed that a large volume of fluid was shifted out of the legs early in the flight. A much greater increase in leg volume occurred during inflight LBNP than in preflight tests. Resting heart rates tended to be low early in the flight and to increase slightly as it progressed, while resting blood pressure varied. The LBNP protocol was a greater stress inflight, and the tests had to be stopped early on three occasions due to impending syncopal reactions. Inflight LBNP responses seemed to predict the degree of postflight orthostatic intolerance. Postflight responses to LBNP during the first 48 hours were characterized by marked elevations in heart rate, instability in blood pressure, and considerably elevated systolic and diastolic pressures both at rest and during stress.

Johnson, R. L.↗

Transport Processes in the Upper Atmosphere

A proposed study to measure aerodynamic and heat transfer coefficients within the thermo-fluid-dynamic range experienced by a tethered satellite and to compare the coefficients with previous correlations is discussed. Tests are proposed on a satellite of existing design, on a satellite design consisting of models carried aboard, and on a newly designed satellite devoted to energy, mass, and momentum transfer studies on particular geometries.

Carlomagno, G. M.↗

Gas-phase flowrate effect on disintegrating cryogenic liquid-jets

Two phase liquid and gaseous nitrogen flow in a pneumatic two fluid atomizer was investigated. Characteristic dropsize for cryogenic sprays were measured with a scattered light scanning instrument developed at NASA-Lewis. Tests were conducted primarily in the aerodynamic stripping regime of liquid jet atomization. At a sampling distance of bar-x=1.3 cm, the Sauter mean, D(sub 32), and volume median, D(sub v.5), drop diameters were measured and correlated with nitrogen gas flowrate, W(sub n), to give the following expressions: D sub 32 to the -1=210W(sub n) to the -1.33 and D(sub v.5) to the -1=150 W(sub n to the -1.33, where reciprocal diameters and gas flowrate are in cm (-1) and g/sec, respectively. The exponent 1.33 for nitrogrn gas flowrate, W(sub n), is the same as that predicted by atomization theory for liquid-jet breakup in high velocity gasflow. When the spray was sampled at axial distances of bar-x=2.5 and 4.5 cm downstream of the atomizer, the exponent decreased to 1.2 and 0.9, respectively. This was attributed to the loss of small droplets due to their rapid vaporization.

Ingebo, Robert D.↗

Consortium for materials development in space

The status of the Consortium for Materials Development in Space (CMDS) is reviewed. Individual CMDS materials projects and flight opportunities on suborbital and orbital carriers are outlined. Projects include: surface coatings and catalyst production; non-linear optical organic materials; physical properties of immiscible polymers; nuclear track detectors; powdered metal sintering; iron-carbon solidification; high-temperature superconductors; physical vapor transport crystal growth; materials preparation and longevity in hyperthermal oxygen; foam formation; measurement of the microgravity environment; and commercial management of space fluids.

Source record↗