Search NASA⌕ Search

SEARCH · Search NASA

Results for “Gas sample analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Enhanced Raman Monitor Project

Monitoring of gaseous contaminants stems from the need to ensure a healthy and safe environment. NASA/Ames needs sensors that are able to monitor common atmospheric gas concentrations as well as trace amounts of contaminant gases. To provide an accurate assessment of air quality, a monitoring system would need to be continuous and on-line with full spectrum capabilities, allowing simultaneous detection of all gas components in a sample, including both combustible and non-combustible gases. The system demands a high degree of sensitivity to detect low gas concentrations in the low-ppm and sub-ppm regions. For clean and healthy air ('good' category), criteria established by the EPA requires that contaminant concentrations not exceed 4 ppm of carbon monoxide (CO) in an 8 hour period, 60 ppb of ozone(O3) in a one hour period and 30 ppb of sulfur dioxide (SO2) in a 24 hour period. One step below this is the National Ambient Air Quality Standard ('moderate' category) which requires that contaminant concentrations not exceed 9 ppm of carbon monoxide (CO), 120 ppb of ozone (O3) and 140 ppb of sulfur dioxide (SO2) for their respective time periods. Ideally a monitor should be able to detect the concentrations specified in the 'good' category. To benchmark current abilities of Raman technology in gas phase analysis, laboratory experiments were performed to evaluate the RASCAL II anesthetic gas monitor.

Westenskow, Dwayne↗

RESOLVE (Regolith & Environmental Science Oxygen & Lunar Volatile Extraction) Project

The RESOLVE Project is a lunar prospecting mission whose primary goal is to characterize water and other volatiles in lunar regolith. The Lunar Advanced Volatiles Analysis (LAVA) subsystem is comprised of a fluid subsystem that transports flow to the gas chromatograph - mass spectrometer (GC-MS) instruments that characterize volatiles and the Water Droplet Demonstration (WDD) that will capture and display water condensation in the gas stream. The LAVA Engineering Test Unit (ETU) is undergoing risk reduction testing this summer and fall within a vacuum chamber to understand and characterize component and integrated system performance. Testing of line heaters, printed circuit heaters, pressure transducers, temperature sensors, regulators, and valves in atmospheric and vacuum environments was done. Test procedures were developed to guide experimental tests and test reports to analyze and draw conclusions from the data. In addition, knowledge and experience was gained with preparing a vacuum chamber with fluid and electrical connections. Further testing will include integrated testing of the fluid subsystem with the gas supply system, near-infrared spectrometer for the Surge Tank (NIRST), WDD, Sample Delivery System, and GC-MS in the vacuum chamber. Since LAVA is a scientific subsystem, the near infrared spectrometer and GC-MS instruments will be tested during the ETU testing phase.

LAVA↗

Generating Global CH4 NASA GEOS Product by Assimilating TROPOMI

Radiative properties of methane (CH4) significantly contribute to climate change and the recent acceleration of global CH4 growth requires thorough investigation into its causes. Examination of temporal and spatial CH4 variability is crucial for better understanding the shifts that are currently taking place. Integrating different CH4 observations to create a reliable, easily to use global atmospheric CH4 product could contribute to assessment of emissions processes, but remains challenging due to the lack of long satellite data records. Here we present the NASA Goddard Earth Observing System (GEOS) based global CH4 product constrained by atmospheric transport from the Modern-Era Retrospective analysis for Research and Applications, Version 2 (MERRA-2) and assimilated CH4 from the TROPOspheric Monitoring Instrument (TROPOMI). This product uses the Constituent Data Assimilation System (CoDAS) component of the GEOS capability, which has been expanded and generalized to assimilate any satellite, ground-based, or in situ observation of atmospheric composition that can be expressed as a vertical sounding or point sample. The product is similar to the one generated by assimilating carbon dioxide (CO2) data into GEOS from Orbiting Carbon Observatory 2 (OCO-2): OCO-2 GEOS Level 3 daily and monthly, 0.5x0.625 assimilated CO2 V10r. The preliminary product is investigated using a variety of quality check approaches with the help of in situ observations to examine bias correction, error inflation, and performance of the assimilation system. Potential applications of this approach include support for interpretation of high-resolution point source detection approaches, climate and greenhouse gas reanalyses, and boundary conditions for regional modeling approaches.

Nikolay Balashov↗

Drying Simulated Advanced Gas Reactor Fuel: Proving the Concept - 17637

Spent Nuclear Fuel (SNF) reprocessing is due to cease in the UK in 2018 and a new interim storage method may be required if it is found that pond storage is not viable beyond the 25 year period which is currently understood to be safe. Dry storage has been used elsewhere in the world for zircaloy and aluminium clad fuel and has been proposed for use in the UK, however since the UK's fuel is predominantly stainless steel (SS) clad, testing will need to be carried out to ensure that drying methods are suitable. This will require representative samples for macro scale drying tests. To date, little long term stored fuel has been examined. As a result, work has been carried out to try and ascertain whether the corrosion associated with long term storage leads to significant bound water and whether through wall cracks can be formed in intact lengths of SS tube. It was found that unlike an aluminium simulant, corroded SS showed no sign of water loss as a result of oxide dehydration during controlled drying by thermogravimetric analysis, and consequently bound water could be disregarded. It was also found that through wall cracks could be produced in an intact length of SS tube which would be suitable for macro scale drying tests. Some initial macro scale drying tests have been carried out using an alternative test piece with preformed cracks, and three distinct drying regimes to complete dryness have been detected. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Smartphone-based Dual-channel Immunochromatographic Test Strip with Polymer Quantum Dot Labels for Simultaneous Detection of Cypermethrin and 3-phenoxybenzoic acid

Currently, gas chromatography-mass spectrometry (GC-MS) and liquid chromatography-mass spectrometry (LC-MS) are the primary methods used to detect pesticides and their metabolites for biomonitoring of exposure. Although GC-MS and LC-MS can provide accurate and sensitive measurements, these techniques are not suitable for point-of-care or in-field biomonitoring applications. The objective of this work is to develop a smartphone-based dual-channel immunochromatographic test strip (ICTS) for on-site biomonitoring of exposure to cypermethrin by simultaneous detection of cypermethrin and its metabolite, 3-phenoxybenzoic acid (3-PBA). Polymer carbon dots (PCDs) with ultra-high fluorescent brightness were synthesized and used as signal amplifier in ICTS assay. Cypermethrin (a representative pyrethroid pesticide) and its major metabolite 3-PBA were simultaneously detected to provide more comprehensive analysis of cypermethrin exposure. After competitive immunoreactions between the target sample and the coating antigens preloaded on the test line, the tracer antibody (PCDs conjugated antibody) was quantitatively captured on the test lines. The captured PCDs were inversely proportional to the amount of the target compound in sample. The red fluorescence on the test line then was recorded by a smartphone-based device capable of conducting image analysis and recording. Under optimal conditions, the sensor showed excellent linear responses for detecting cypermethrin and 3-PBA ranging from 1 ng/mL to 100 ng/mL and from 0.1 ng/mL to 100 ng/mL, the limits of detection were calculated to be ~0.35 ng/mL for cypermethrin and ~0.04 ng/mL for 3-PBA, respectively. The results demonstrate that the ICTS device is promising for accurate point-of-care biomonitoring of pesticide exposure.

Zhao, Yuting↗

Species-Selective Detection of Volatile Organic Compounds by Ionic Liquid-Based Electrolyte Using Electrochemical Methods

The detection of volatile organic compounds (VOCs) is an important topic for environmental safety and public health. However, the current commercial VOC detectors suffer from cross-sensitivity and low reproducibility. In this work, we present species-selective detection for VOCs using an electrochemical cell based on ionic liquid (IL) electrolytes with features of high selectivity and reliability. The voltammograms measured with the IL-based electrolyte absorbing different VOCs exhibited species-selective features that were extracted and classified by linear discriminant analysis (LDA). The detection system could identify as many as four types of VOCs, including methanol, ethanol, acetone, formaldehyde, and additional water. A mixture of methanol and formaldehyde was detected as well. The sample required for the VOCs classification system was 50 μL, or 1.164 mmol, on average. The response time for each VOC measurement is as fast as 24 s. The volume of VOCs such as formaldehyde in solution could also be quantified by LDA and electrochemical impedance spectroscopy techniques, respectively. The system showed a tunable detection range for 1.6 and 16% (w/v) CH 2 O solution by adjusting the composition of the electrolyte. The limit of detection was as low as 1 μL. For the 1.6% CH 2 O solution, the linearity calibration range was determined to be from 5.30 to 53.00 μmol with a limit of detection at 0.53 μmol. The mechanisms for VOCs determination and quantification are also thoroughly discussed. Finally, it is expected that this work could provide a new insight into the concept of electrochemical detection of VOCs with machine learning analysis and be applied to both VOCs gas monitoring and fluid detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The H I absorption zoo: JVLA extension to z ~ 0.4

Here, we present an H I 21 cm absorption study of a sample of 26 radio-loud active galactic nuclei (AGN) at 0.25 < z < 0.4 carried out with the Karl G. Jansky Very Large Array. Our aim was to study the rate of incidence of H I in different classes of radio AGN, the morphology and kinematics of the detected H I, and the nature of the interaction between the H I and the radio source at these redshifts. Our sample consists of 14 sources with sizes of up to tens of kpc and 12 compact sources (< a few kpc) in the radio-power range 10 25.7 W Hz –1 –10 26.5 W Hz –1 . We detect H I in five sources, corresponding to a detection rate of ~19%. Within the error bars, this agrees with the detection rate found at lower redshifts. We find that the rest-frame UV luminosities of most of the sources in the sample, including all the detections, are below the proposed threshold above which the H I is supposed to have been ionised. An analysis of the optical emission-line spectra of the sources shows that despite their high radio powers, about one-third of the sample, including two detections, are low-ionisation sources. The radio continuum emission from the sources detected in H I is unresolved at ~5 to 10 kpc scales in our observations, but shows extended structure on parsec scales. We analysed the H I 21 cm absorption spectra of the detections to understand the morphology and kinematics of H I. The absorption profiles are mostly complex with widths between the nulls ranging from ~60 km s –1 to 700 km s –1 . These detections also exhibit remarkably high H I column densities in the range ~10 21 cm –2 –10 22 cm –2 for T spin = 100 K and unit covering factor. Our modelling of the H I 21 cm absorption profiles suggests that in two sources the gas appears to be disturbed, and in three cases, including one with disturbed H I, the majority of the absorption is consistent with it arising from an H I disc. Despite the high radio power of our sources, we do not detect fast outflows. However, the optical emission lines in these detections show the presence of significantly disturbed gas in the nuclear regions in the form of very wide and highly blueshifted emission-line components. Since some of our detections are also low-ionisation AGN, it is quite possible that this disturbance is caused by the radio jets. Overall, our findings point towards a continuation of the low-z trends in the H I detection rate and the incidence of H I in radio AGN up to z ~ 0.4.

79 ASTRONOMY AND ASTROPHYSICS↗

The Warm Circumgalactic Medium: 10{sup 5−6} K Gas Associated with a Single Galaxy Halo or with an Entire Group of Galaxies?

In preparation for a Hubble Space Telescope (HST) observing project using the Cosmic Origins Spectrograph (COS), the positions of all AGN targets having high-S/N far-UV G130M spectra were cross-correlated with a large catalog of low-redshift galaxy groups homogenously selected from the spectroscopic sample of the Sloan Digital Sky Survey (SDSS). Searching for targets behind only those groups at z = 0.1–0.2 (which places the O vi doublet in the wavelength region of peak COS sensitivity), we identified only one potential S/N=15--20 target, FBQS 1010+3003. An O vi-only absorber was found in its G130M spectrum at z = 0.11326, close to the redshift of a foreground small group of luminous galaxies at z = 0.11685. Because there is no associated Lyα absorption, any characterization of this absorber is necessarily minimal; however, the O vi detection likely traces “warm” gas in collisional ionization equilibrium at T ≈ 3 × 10{sup 5} K. While this discovery is consistent with being interface gas between cooler, photoionized clouds and a hotter intra-group medium, it could also be warm, interface gas associated with the circumgalactic medium (CGM) of the single closest galaxy. In this case, a detailed analysis of the galaxy distribution (complete to 0.2 L{sup ∗}) strongly favors the individual galaxy association. This analysis highlights the necessity of both high-S/N>20 COS data and a deep galaxy redshift survey of the region in order to test more rigorously the association of O vi-absorbing gas with a galaxy group. A Cycle 23 HST/COS program is currently targeting 10 UV-bright AGN behind 12 low-redshift galaxy groups to test the warm, group gas hypothesis.

79 ASTRONOMY AND ASTROPHYSICS↗

Repetitive Interrogation of 2-Level Quantum Systems

Trapped ion clocks derive information from a reference atomic transition by repetitive interrogations of the same quantum system, either a single ion or ionized gas of many millions of ions. Atomic beam frequency standards, by contrast, measure reference atomic transitions in a continuously replenished "flow through" configuration where initial ensemble atomic coherence is zero. We will describe some issues and problems that can arise when atomic state selection and preparation of the quantum atomic system is not completed, that is, optical pumping has not fully relaxed the coherence and also not fully transferred atoms to the initial state. We present a simple two-level density matrix analysis showing how frequency shifts during the state-selection process can cause frequency shifts of the measured clock transition. Such considerations are very important when a low intensity lamp light source is used for state selection, where there is relatively weak relaxation and re-pumping of ions to an initial state and much weaker 'environmental' relaxation of the atomic coherence set-up in the atomic sample.

Rabi interrogation↗

Chlorine Isotopic Compositions of Apatite in Apollo 14 Rocks: Evidence for Widespread Vapor-Phase Metasomatism on the Lunar Nearside ~4 Billion Years Ago

Compared to most other planetary materials in the Solar System, some lunar rocks display high delta (sup 37) Cl signatures. Loss of Cl in a H<<Cl environment has been invoked to explain the heavy signatures observed in lunar samples, either during volcanic eruptions onto the lunar surface or during large scale degassing of the lunar magma ocean. To explore the conditions under which Cl isotope fractionation occurred in lunar basaltic melts, five Apollo 14 crystalline samples were selected (14053,19, 14072,13, 14073,9, 14310,171 along with basaltic clast 14321,1482) for in situ analysis of Cl isotopes using secondary ion mass spectrometry. Cl isotopes were measured within the mineral apatite, with delta (sup 37) Cl values ranging from +14.6 ± 1.6 per mille to +40.0 ± 2.9 per mille. These values expand the range previously reported for apatite in lunar rocks, and include some of the heaviest Cl isotope compositions measured in lunar samples to date. The data here do not display a trend between increasing rare earth elements contents and delta (sup 37) Cl values, reported in previous studies. Other processes that can explain the wide inter- and intra-sample variability of delta (sup 37) Cl values are explored. Magmatic degassing is suggested to have potentially played a role in fractionating Cl isotope in these samples. Degassing alone, however, could not create the wide variability in isotopic signatures. Our favored hypothesis, to explain small scale heterogeneity, is late-stage interaction with a volatile-rich gas phase, originating from devolatilization of lunar surface regolith rocks ~4 billion years ago. This period coincides with vapor-induced metasomastism recorded in other lunar samples collected at the Apollo 16 and 17 landing sites, pointing to the possibility of widespread volatile-induced metasomatism on the lunar nearside at that time, potentially attributed to the Imbrium formation event.

apatit↗

Advanced Test Reactor Safety Basis Update for Gas-Cooled Experiments

The Advanced Test Reactor (ATR) supports neutron irradiation of several types of experiments. One such experiment type is referred to as a gas leadout. Gas leadout experiments actively flow gas through the experiment which allows for active temperature control. It also allows for in-situ data of the experiment. For example, fission gas migration through a fuel sample can be monitored via activity of the sweep gas. Historically, ex-pile equipment and fission product monitors were housed in shielded ATR cubicles. Due to other facility updates, cubicle space is no longer available for gas leadout experiment equipment. To support continued operation of gas leadout experiments, ATR completed a safety basis update that supports a new housing for leadout equipment that may process potentially contaminated gas. In addition to the structure and associated equipment, technical safety requirements regarding handling and storage of experiments needed to be revised to support fueled gas leadout experiments and associated outage configurations. The safety basis update addressed the full lifecycle of these experiments, including experiment movement and interim storage, and credible abnormal events such as failures or leaks in contaminated gas tubing in occupied areas. This paper discusses the completed analyses performed to support the safety basis update associated with gas leadout experiments, including thermal-hydraulic evaluation, probabilistic analysis, and dose consequence analyses.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observations of Southeast Asian Biomass Burning and Urban Trace Gas Enhancement Ratios: Insights into Regional Air Quality and Aerosol Composition

Southeast Asian biomass burning is a major pollutant source that contributes to poor air quality throughout the region. Thus, understanding these emissions is critical for predicting and mitigating their health impacts. While many studies have reported ground-based and satellite measurements, airborne measurements at a regional scale capable of tying the two together have not been common. The 2019 Cloud, Aerosol and Monsoon Processes Philippines Experiment (CAMP2Ex) field project examined Southeast Asian regional sources and their effects on aerosol/cloud interactions using a combination of airborne, shipboard, and ground-based measurements. These flights sampled a variety of airmass sources over the Philippine, South China, and Sulu seas during both the southwest monsoon and monsoon transition periods. Measurements during CAMP2Ex provide a unique opportunity to investigate how these transported and local emissions affected air quality trends and airmass chemical composition. We present correlated airborne in situ enhancement ratios of CH4 to CO, using them to identify source regimes of either high urban or biomass burning influence as well as urban regimes with different emission factors. Combined with backtrajectory analysis using HYSPLIT, source regimes were examined for differences in ozone, reactive nitrogen, and aerosol chemical composition. While observed O3/CO enhancement ratios remain constant for differing urban source regimes, NOy/CO ratios varied across these regimes. For biomass burning sources, O3/CO enhancement ratios are observed to be lower than previously reported by measurements in the region.

Joshua P Digangi↗

High-temperature Tribological Behavior of Structural Materials after Conditioning in Impure-Helium Environments for High_temperature Gas-Cooled Reactor Applications

Incoloy 800HT and Inconel 617 have been selected as candidate structural alloys for the hightemperature gas-cooled reactor (HTGR) concept. Helium, the primary coolant, contains impurities (e.g., H2O and CH4) that can induce corrosion reactions at high temperatures, which in turn can affect the tribological behavior of components in sliding contact such as valves and control-rod drive systems. This paper presents results from the study of the tribological behavior of both alloys before and after conditioning them in either an impure-helium oxidizing environment or in an air environment. Both alloys were conditioned for 22 days at elevated temperatures in a once-through helium loop with 4 ppmv H2O and tested subsequently at elevated temperatures with a pin-on-disk tribometer in an air environment 650 degrees C and 750 degrees C for 800HT; 850 degrees C and 900 degrees C for 617 - with various applied loads - 1 N, 2 N and 5 N. SEM-EDS analysis revealed that conditioning the samples in an oxidizing environment leads to the formation of a mixed Fe/Cr-oxide on alloy 800HT and a Cr-oxide on alloy 617, both increasing the wear resistance compared to that of as-received samples. Alloy 617 exhibited lower steady-state friction coefficients compared to those of alloy 800HT. There was a significant decrease in the scatter of the steadystate friction coefficient of the conditioned samples compared to that of the unconditioned samples. The steady-state friction coefficient for alloy 800HT and 617 were found to be 0.53 +/- 0.07 and 0.25 +/- 0.04, respectively. The wear resistance of alloy 800HT is approximately one order of magnitude lower than that of alloy 617 in all cases that exhibited measurable wear. After sample conditioning, the wear volumes measured at low loads were undistinguishable from the unworn background, a result attributed to the formation of a compacted glaze layer under high temperatures and high contact stresses.

Alloys 800 and 617↗

MAJOR-MERGER GALAXY PAIRS AT Z = 0: DUST PROPERTIES AND COMPANION MORPHOLOGY

We present an analysis of dust properties of a sample of close major-merger galaxy pairs selected by K {sub s} magnitude and redshift. The pairs represent the two populations of spiral–spiral (S+S) and mixed morphology spiral–elliptical (S+E). The Code Investigating GALaxy Emission software is used to fit dust models to the Two Micron All Sky Survey, Wide-Field Infrared Survey Explorer , and Herschel flux density measurements, and to derive the parameters describing the polycyclic aromatic hydrocarbons contribution, interstellar radiation field, and photodissociation regions. Model fits verify our previous Spitzer Space Telescope analysis that S+S and S+E pairs do not have the same level of enhancement of star formation and differ in dust composition. The spirals of mixed-morphology galaxy pairs do not exhibit the enhancements in interstellar radiation field and therefore dust temperature for spirals in S+S pairs in contrast to what would be expected according to standard models of gas redistribution due to encounter torques. This suggests the importance of the companion environment/morphology in determining the dust properties of a spiral galaxy in a close major-merger pair.

79 ASTRONOMY AND ASTROPHYSICS↗

ABSORPTION-LINE SPECTROSCOPY OF GRAVITATIONALLY LENSED GALAXIES: FURTHER CONSTRAINTS ON THE ESCAPE FRACTION OF IONIZING PHOTONS AT HIGH REDSHIFT

The fraction of ionizing photons escaping from high-redshift star-forming galaxies is a key obstacle in evaluating whether galaxies were the primary agents of cosmic reionization. We previously proposed using the covering fraction of low-ionization gas, measured via deep absorption-line spectroscopy, as a proxy. We now present a significant update, sampling seven gravitationally lensed sources at 4 < z < 5. We show that the absorbing gas in our sources is spatially inhomogeneous, with a median covering fraction of 66%. Correcting for reddening according to a dust-in-cloud model, this implies an estimated absolute escape fraction of ≃19% ± 6%. With possible biases and uncertainties, collectively we find that the average escape fraction could be reduced to no less than 11%, excluding the effect of spatial variations. For one of our lensed sources, we have sufficient signal-to-noise ratio to demonstrate the presence of such spatial variations and scatter in its dependence on the Ly α equivalent width, consistent with recent simulations. If this source is typical, our lower limit to the escape fraction could be reduced by a further factor ≃2. Across our sample, we find a modest anticorrelation between the inferred escape fraction and the local star formation rate, consistent with a time delay between a burst and leaking Lyman continuum photons. Our analysis demonstrates considerable variations in the escape fraction, consistent with being governed by the small-scale behavior of star-forming regions, whose activities fluctuate over short timescales. This supports the suggestion that the escape fraction may increase toward the reionization era when star formation becomes more energetic and burst-like.

79 ASTRONOMY AND ASTROPHYSICS↗

The MESUR Mission

The MESUR mission will place a network of small, robust landers on the Martian surface, making a coordinated set of observations for at least one Martian year. MESUR presents some major challenges for development of instruments, instrument deployment systems, and on board data processing techniques. The instrument payload has not yet been selected, but the straw man payload is (1) a three-axis seismometer; (2) a meteorology package that senses pressure, temperature, wind speed and direction, humidity, and sky brightness; (3) an alphaproton-X-ray spectrometer (APXS); (4) a thermal analysis/evolved gas analysis (TA/EGA) instrument; (5) a descent imager, (6) a panoramic surface imager; (7) an atmospheric structure instrument (ASI) that senses pressure, temperature, and acceleration during descent to the surface; and (8) radio science. Because of the large number of landers to be sent (about 16), all these instruments must be very lightweight. All but the descent imager and the ASI must survive landing loads that may approach 100 g. The meteorology package, seismometer, and surface imager must be able to survive on the surface for at least one Martian year. The seismometer requires deployment off the lander body. The panoramic imager and some components of the meteorology package require deployment above the lander body. The APXS must be placed directly against one or more rocks near the lander, prompting consideration of a micro rover for deployment of this instrument. The TA/EGA requires a system to acquire, contain, and heat a soil sample. Both the imagers and, especially, the seismometer will be capable of producing large volumes of data, and will require use of sophisticated data compression techniques.

Squyres, S. W.↗

A high-speed, high-performance, microfabricated comprehensive two-dimensional gas chromatograph

A small, consumable-free, low-power, ultra-high-speed comprehensive GC×GC system consisting of microfabricated columns, nanoelectromechanical system (NEMS) cantilever resonators for detection, and a valve-based stop-flow modulator is demonstrated. The separation of a highly polar 29-component mixture covering a boiling point range of 46 to 253 °C on a pair of microfabricated columns using a Staiger valve manifold in less than 7 seconds, and just over 4 seconds after the ensemble holdup time is demonstrated with a downstream FID. The analysis time of the second dimension was 160 ms, and peak widths in the second dimension range from 10–60 ms. A peak capacity of just over 300 was calculated for a separation of just over 6 s. Data from a continuous operation testing over 40 days and 20 000 runs of the GC×GC columns with the NEMS resonators using a 4-component test set is presented. As a result, the GC×GC-NEMS resonator system generated second-dimension peak widths as narrow as 8 ms with no discernable peak distortion due to under-sampling from the detector.

47 OTHER INSTRUMENTATION↗

Galvanic corrosion of structural non-stoichiometric silicon nitride thin films and its implications on reliability of microelectromechanical devices

This paper describes a reliability assessment and failure analysis of a poly-Si/non-stoichiometric silicon nitride thin film composite structure. A set of poly-Si/SiN{sub x} thin film structures were exposed to a mixed flowing gas (MFG) environment, which simulates outdoor environments, for 90 days, and an elevated temperature and humidity (85 °C/95% R.H.) test for 140 days. The mechanical integrity of the thin films was observed to degrade during exposure to the chemically reactive atmospheres. The degree of degradation was analyzed with nanoindentation tests. Statistical analysis of the forces required to initiate a fracture in the thin films indicated degradation due to the exposure to the MFG environment in the SiN{sub x} part of the films. Scanning electron microscopy revealed a porous-like reaction layer on top of SiN{sub x}. The morphology of the reaction layer resembled that of galvanically corroded poly-Si. Transmission electron microscopy further clarified the microstructure of the reaction layer which had a complex multi-phase structure extending to depths of ∼100 nm. Furthermore, the layer was oxidized two times deeper in a 90 days MFG-tested sample compared to an untested reference. The formation of the layer is proposed to be caused by galvanic corrosion of elemental silicon in non-stoichiometric silicon nitride during hydrofluoric acid etching. The degradation is proposed to be due uncontrolled oxidation of the films during the stress tests.

36 MATERIALS SCIENCE↗