Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Growth of the (In{sub 2}S{sub 3}){sub x}(FeIn{sub 2}S{sub 4}){sub 1-x} single crystals and properties of photoelectric structures on their basis

Complete mutual solubility in the (In{sub 2}S{sub 3}){sub x}(FeIn{sub 2}S{sub 4}){sub 1-x} system is established. The technology is developed, and single crystals of the continuous series of the (In{sub 2}S{sub 3}){sub x}(FeIn{sub 2}S{sub 4}){sub 1-x} solid solutions are grown for the first time. The linear dependence of the unit cell parameter of single crystals with a cubic spinel lattice on the solid solution composition is found. First, photosensitive Schottky barriers are fabricated, and then, based on studies of their photosensitivity, the character of band-to-band transition is discussed and the values of the band gap depending on the atomic composition are estimated. The possibility of using the obtained solid solutions as broadband photoconverters of optical radiation is revealed.

36 MATERIALS SCIENCE↗

Modeling Charge Transfer Excitation with Variation After Response Quantum Monte Carlo (Final Technical Report)

The electronically excited states of molecules play critical roles both in spectroscopy and in technological application, ranging from UV/Vis absorption experiments to the production of solar fuels. However, certain types of excitations, such as charge transfer excitations, remain difficult to treat with existing methods such as time dependent density functional theory or linear response coupled cluster. Under this Early Career Research Award, we developed a number of different theoretical methods to address this issue, which began with Variational Monte Carlo methods and branched into multiple types of excited-state-specific quantum chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Low-G fluid transfer technology study

Technology gaps and system characteristics critical to cryogenic and noncryogenic in-orbit fluid transfer were identified. Four different supply systems were conceptually designed as space shuttle payloads. These were; (1) space tug supply - LH2, LO2, N2H4, He - linear acceleration for liquid acquisition with supply module and tug separated from shuttle, (2) tug supply using orbiter drag, (3) orbiter supply - N2O4,MMH,He, H2,O2 - surface tension screens, (4) multiple receivers supply 0 solar electric propulsion stage, Hg, diaphragm - HEAO B, HEe, paddle fluid rotation-satellite control section, N2H4, screens. It was found that screens had the best overall potential for low weight and simplicity, however, thermal problems with cryogenics still need final resolution.

Stark, J. A.↗

Large liquid rocket engine transient performance simulation system

A simulation system, ROCETS, was designed and developed to allow cost-effective computer predictions of liquid rocket engine transient performance. The system allows a user to generate a simulation of any rocket engine configuration using component modules stored in a library through high-level input commands. The system library currently contains 24 component modules, 57 sub-modules and maps, and 33 system routines and utilities. FORTRAN models from other sources can be operated in the system upon inclusion of interface information on comment cards. Operation of the simulation is simplified for the user by run, execution, and output processors. The simulation system makes available steady-state trim balance, transient operation, and linear partial generation. The system utilizes a modern equation solver for efficient operation of the simulations. Transient integration methods include integral and differential forms for the trapezoidal, first order Gear, and second order Gear corrector equations. A detailed technology test bed engine (TTBE) model was generated to be used as the acceptance test of the simulation system. The general level of model detail was that reflected in the Space Shuttle Main Engine DTM. The model successfully obtained steady-state balance in main stage operation and simulated throttle transients, including engine starts and shutdown. A NASA FORTRAN control model was obtained, ROCETS interface installed in comment cards, and operated with the TTBE model in closed-loop transient mode.

Mason, J. R.↗

Development of improved space sampling strategies for ocean chemical properties: Total carbon dioxide and dissolved nitrate

Large-scale ocean observing programs such as the Joint Global Ocean Flux Study (JGOFS) and the World Ocean Circulation Experiment (WOCE) today, must face the problem of designing an adequate sampling strategy. For ocean chemical variables, the goals and observing technologies are quite different from ocean physical variables (temperature, salinity, pressure). We have recently acquired data on the ocean CO2 properties on WOCE cruises P16c and P17c that are sufficiently dense to test for sampling redundancy. We use linear and quadratic interpolation methods on the sampled field to investigate what is the minimum number of samples required to define the deep ocean total inorganic carbon (TCO2) field within the limits of experimental accuracy (+/- 4 micromol/kg). Within the limits of current measurements, these lines were oversampled in the deep ocean. Should the precision of the measurement be improved, then a denser sampling pattern may be desirable in the future. This approach rationalizes the efficient use of resources for field work and for estimating gridded (TCO2) fields needed to constrain geochemical models.

Goyet, Catherine↗

Sub-Shot Noise Power Source for Microelectronics

Low-current, high-impedance microelectronic devices can be affected by electric current shot noise more than they are affected by Nyquist noise, even at room temperature. An approach to implementing a sub-shot noise current source for powering such devices is based on direct conversion of amplitude-squeezed light to photocurrent. The phenomenon of optical squeezing allows for the optical measurements below the fundamental shot noise limit, which would be impossible in the domain of classical optics. This becomes possible by affecting the statistical properties of photons in an optical mode, which can be considered as a case of information encoding. Once encoded, the information describing the photon (or any other elementary excitations) statistics can be also transmitted. In fact, it is such information transduction from optics to an electronics circuit, via photoelectric effect, that has allowed the observation of the optical squeezing. It is very difficult, if not technically impossible, to directly measure the statistical distribution of optical photons except at extremely low light level. The photoelectric current, on the other hand, can be easily analyzed using RF spectrum analyzers. Once it was observed that the photocurrent noise generated by a tested light source in question is below the shot noise limit (e.g. produced by a coherent light beam), it was concluded that the light source in question possess the property of amplitude squeezing. The main novelty of this technology is to turn this well-known information transduction approach around. Instead of studying the statistical property of an optical mode by measuring the photoelectron statistics, an amplitude-squeezed light source and a high-efficiency linear photodiode are used to generate photocurrent with sub-Poissonian electron statistics. By powering microelectronic devices with this current source, their performance can be improved, especially their noise parameters. Therefore, a room-temperature sub-shot noise current source can be built that will be beneficial for a very broad range of low-power, low-noise electronic instruments and applications, both cryogenic and room-temperature. Taking advantage of recent demonstrations of the squeezed light sources based on optical micro-disks, this sub-shot noise current source can be made compatible with the size/power requirements specific of the electronic devices it will support.

Strekalov, Dmitry V.↗

Measured Polarized Spectral Responsivity of JPSS J1 VIIRS Using the NIST T-SIRCUS

Recent pre-launch measurements performed on the Joint Polar Satellite System (JPSS) J1 Visible Infrared Imaging Radiometer Suite (VIIRS) using the National Institute of Standards and Technology (NIST) Traveling Spectral Irradiance and Radiance Responsivity Calibrations Using Uniform Sources (T-SIRCUS) monochromatic source have provided wavelength dependent polarization sensitivity for select spectral bands and viewing conditions. Measurements were made at a number of input linear polarization states (twelve in total) and initially at thirteen wavelengths across the bandpass (later expanded to seventeen for some cases). Using the source radiance information collected by an external monitor, a spectral responsivity function was constructed for each input linear polarization state. Additionally, an unpolarized spectral responsivity function was derived from these polarized measurements. An investigation of how the centroid, bandwidth, and detector responsivity vary with polarization state was weighted by two model input spectra to simulate both ground measurements as well as expected on-orbit conditions. These measurements will enhance our understanding of VIIRS polarization sensitivity, improve the design for future flight models, and provide valuable data to enhance product quality in the post-launch phase.

JPSS↗

First Application of the Zeeman Technique to Remotely Measure Auroral Electrojet Intensity From Space

Using the O2 118 GHz spectral radiance measurements obtained by the Microwave Limb Sounder instrument on board the Aura spacecraft, we demonstrate that the Zeeman effect can be used to remotely measure the magnetic field perturbations produced by the auroral electrojet near the Hall current closure altitudes. Our derived current-induced magnetic field perturbations are found to be highly correlated with those coincidently obtained by ground magnetometers. These perturbations are also found to be linearly correlated with auroral electrojet strength. The statistically derived polar maps of our measured magnetic field perturbation reveal a spatial-temporal morphology consistent with that produced by the Hall current during substorms and storms. With today's technology, a constellation of compact, low-power, high spectral-resolution cubesats would have the capability to provide high precision and spatiotemporal magnetic field samplings needed for auroral electrojet measurements to gain insights into the spatiotemporal behavior of the auroral electrojet system.

spectral radiance measurements; Aur↗

Battery Cell-to-Pack Scaling Laws for Electric Aircraft

Battery pack gravimetric energy density is one of the most important, yet often miss-estimated design parameters for sizing all-electric aircraft. Proper accounting for thermal, structural, and operational safety margins are frequently lost when extrapolating performance from the cell level to the aircraft level. This paper summarizes the relevant engineering and certification details needed to better account for the penalties associated when assembling battery packs. The relationship between the cell and pack energy density is not linear, as is often assumed. Furthermore, the relationship varies depending on pack requirements, cell chemistry, and architecture. Parametric, high-fidelity models are used to determine optimal battery pack sizes over a range of conditions to better quantify technology scaling effects.

Battery Electric Aircraft↗

Battery Cell-to-Pack Scaling Trends for Electric Aircraft

Battery pack gravimetric energy density is one of the most important, yet often miss- estimated design parameters for sizing all-electric aircraft. Proper accounting for thermal, structural, and operational safety margins are frequently lost when extrapolating performance from the cell level to the aircraft level. This paper summarizes the relevant engineering and certification details needed to better account for the penalties associated when assembling battery packs. The relationship between the cell and pack energy density is not linear, as is often assumed. Furthermore, the relationship varies depending on pack requirements, cell chemistry, and architecture. Parametric, high-fidelity models are used to determine optimal battery pack sizes over a range of conditions to better quantify technology scaling effects.

Battery Electric Aircraft↗

Characterization of a multi-axis ion chamber array

Purpose: The aim of this work was to characterize a multi-axis ion chamber array (IC PROFILER; Sun Nuclear Corporation, Melbourne, FL USA) that has the potential to simplify the acquisition of LINAC beam data. Methods: The IC PROFILER (or panel) measurement response was characterized with respect to radiation beam properties, including dose, dose per pulse, pulse rate frequency (PRF), and energy. Panel properties were also studied, including detector-calibration stability, power-on time, backscatter dependence, and the panel's agreement with water tank measurements [profiles, fractional depth dose (FDD), and output factors]. Results: The panel's relative deviation was typically within ({+-}) 1% of an independent (or nominal) response for all properties that were tested. Notable results were (a) a detectable relative field shape change of {approx}1% with linear accelerator PRF changes; (b) a large range in backscatter thickness had a minimal effect on the measured dose distribution (typically less than 1%); (c) the error spread in profile comparison between the panel and scanning water tank (Blue Phantom, CC13; IBA Schwarzenbruck, DE) was approximately ({+-}) 0.75%. Conclusions: The ability of the panel to accurately reproduce water tank profiles, FDDs, and output factors is an indication of its abilities as a dosimetry system. The benefits of using the panel versus a scanning water tank are less setup time and less error susceptibility. The same measurements (including device setup and breakdown) for both systems took 180 min with the water tank versus 30 min with the panel. The time-savings increase as the measurement load is increased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Twist Engineering of Anisotropic Excitonic and Optical Properties of a Two-Dimensional Magnetic Semiconductor

Two-dimensional (2D) van der Waals (vdW) magnetic semiconductors are a new class of quantum materials for studying the emergent physics of excitons and spins in the 2D limit. Twist engineering provides a powerful tool to manipulate the fundamental properties of 2D vdW materials. Here, in this work, we show that twist engineering of the anisotropic ferromagnetic monolayer semiconductor CrSBr leads to bilayer magnetic semiconductors with continuously tunable magnetic moment, dielectric anisotropy, exciton energy, and linear dichroism. We furthermore provide a model for exciton energy in the media with tunable anisotropy. These results advance fundamental studies of 2D vdW materials and open doors to applications to nano-optics, twistronics, and spintronics.

36 MATERIALS SCIENCE↗

A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider

Herein we present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron–proton and electron–nucleus collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Linear Array Ultrasonic Testing Of A Thick Concrete Specimens For Non-Destructive Evaluation

The University of Minnesota and Oak Ridge National Laboratory are collaborating on the design and construction of a concrete specimen with sufficient reinforcement density and cross-sectional size to represent a light water reactor (LWR) containment wall with various defects. The preliminary analysis of the collected data using extended synthetic aperture focussin technique (SAFT) reconstruction indicated a great potential of the ultrasound array technology for locating relatively shallow distresses. However, the resolution and reliability of the analysis is inversely proportional to the defect depth and the amount of reinforcement between the measurement point and the defect location. The objective of this round of testing is to evaluate repeatability of the obtained reconstructions from measurements with different frequencies as well as to examine the effect of the duration of the sending ultrasound signal on the resulting reconstructions. Two series of testing are performed in this study. The objective of the first series is to evaluate repeatability of the measurements and resulting reconstructed images. The measurements use three center frequencies. Five measurements are performed at each location with and without lifting the device. The analysis of the collected data suggested that a linear array ultrasound system can produce reliably repeatable reconstructions using 50 kHz signals for relatively shallow depths (less than 0.5 m). However, for reconstructions at the greater depths the use of lower frequency and/or signal filtering to reduce the effect of signal noise may be required. The objective of the second series of testing is to obtain measurements with various impulse signal durations. The entire grid on the smooth surface is tested with four different various impulse signal durations. An analysis of the resulting extended SAFT reconstructions suggested that Kirchhoff-based migration leads to easier interpreting reconstructions when shorter duration impulse is used. Longer duration impulses may provide useful information for model-based reconstructions.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Laser-Plasma Wakefield Acceleration with Higher Order Laser Modes

Laser-plasma collider designs point to staging of multiple accelerator stages at the 10 GeV level, which are to be developed on the upcoming BELLA laser, while Thomson Gamma source designs use GeV stages, both requiring efficiency and low emittance. Design and scaling of stages operating in the quasi-linear regime to address these needs are presented using simulations in the VORPAL framework. In addition to allowing symmetric acceleration of electrons and positrons, which is important for colliders, this regime has the property that the plasma wakefield is proportional to the transverse gradient of the laser intensity profile. We demonstrate use of higher order laser modes to tailor the laser pulse and hence the transverse focusing forces in the plasma. In particular, we show that by using higher order laser modes, we can reduce the focusing fields and hence increase the matched electron beam radius, which is important to increased charge and efficiency, while keeping the low bunch emittance required for applications.

43 PARTICLE ACCELERATORS↗

Automated Fluidics Device for Extraction and Quantification of miRNA Biomarkers From Blood

Radiation Assessment DuRing Exposure And long-Duration Spaceflight (RADREADS) demonstrates space-compatible point-of-care technology for quantitative biological monitoring of blood miRNA biomarkers in response to long-term low dose radiation exposure. This individualized monitoring approach will inform targeted treatment strategies to maximize medical resource utilization by accounting for individual susceptibility to radiation-related illnesses. As human spaceflight progresses beyond Earth’s magnetic shielding, radiation exposure poses a significant risk to astronaut health and safety. Extended operation in this environment comes with an increased risk of radiation exposure, leading to higher risks of radiation sickness, cancer, central nervous system effects, and degenerative diseases. While conventional physical dosimetry techniques capture radiation dose, individualistic susceptibility to radiation damage is varied. Multiple characteristics, including age, body weight, sex, genetics, and immune status, have been found to influence radiosensitivity (Liu et al. 2011, and Bouffler 2016). This differential response necessitates individualized monitoring and targeted treatment strategies to maximize medical resource utilization; however, a practical diagnostic platform for quantifying long-term, low dose radiation-induced tissue damage does not currently exist. MicroRNAs (miRNAs) are a class of small, non-coding RNAs that regulate gene expression by mediating the degradation of messenger RNA. The levels of particular miRNAs are influenced by biological processes such as inflammation and serve as biomarkers for a variety of conditions including cancer (Singh et al. 2017). MicroRNAs are found in various bodily fluids and are amenable to collection via liquid biopsies, providing a minimally invasive and easily quantifiable readout for a variety of radiosensitive reporters. A preliminary signature of 15 spaceflight sensitive miRNA has been identified in rodent and human studies, including miR-21-5p, miR-24-3p, miR-92a-3p, miR-17-5p, miR-16a-3p, miR-34a-3p, and miR-223-3p. These targets generally increased expression with radiation dose and linear energy transfer, though variation between individuals is not yet described. Current gaps in the field include a lack of understanding of longitudinal biological responses to long-term, low dose radiation exposure and the absence of space-compatible point-of-care technology for quantitative biological monitoring. In this body of work, we aim to develop an automated bleed-to-read system to process whole blood for the detection of miRNA biomarkers in order to monitor individualistic responses to radiation exposure. This will be achieved via separating serum (or plasma) from whole blood, followed by extraction, amplification, and quantification of the miRNA using a RT-qPCR reaction. Previously, the WetLab-2 hardware enabled execution of a RT-qPCR reaction aboard ISS; however, it is a manual system that requires crew manipulation and bulky components (Parra et al. 2017). To address these issues, automated fluid handling hardware was developed for each stage of sample preparation. Extraction of total RNA is achieved by sequentially pumping reagents through an off-the-shelf nucleic acid binding column (miRNeasy Serum/Plasma Advanced Kit, Qiagen). This approach eliminates several manual pipetting and centrifuging steps and limits the use of toxic chemicals commonly found in other sample processing techniques. The resulting elution will then be automatically dispensed for RT-qPCR analysis using a compact rotary qPCR (Mic qPCR Cycler, Bio Molecular Systems) that will improve spaceflight compatibility by removing bubbles from the detection region, another challenge highlighted by WetLab-2 (Parra et al. 2017). Efforts are also being made to simplify the RT-qPCR reaction to a 1-step air-dryable mix to improve long-term reagent stability at room temperature and reduce system complexity. By automating the RT-qPCR processes via microfluidic manipulation, RADREADS will reduce crewmember hands-on time and enable the personalized detection of radiation-induced tissue damage during long duration missions. Minimally invasive, longitudinal monitoring of individual’s response to radiation exposure will inform how the physiological system responds to long-term low dose space radiation and enables development of targeted countermeasures by the medical team. Ultimately, this portable technology will require minimal technical expertise and can also be used to monitor miRNA biomarkers associated with other diseases.

Tristen Head↗

Phase Contrast Imaging Diagnostic on DIII-D (1994-2007); Phase Contrast Imaging Diagnostic on DIII-D and Alcator C-Mod (2007-2010); Experimental Study of Waves, Turbulence and Transport, and Model Validation with Phase Contrast Imaging on DIII-D and Alcator C-Mod (2010-2012); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Measuring High-k Turbulence and Alfven modes (2021-2016); Phase Contrast Imaging Diagnostic Upgrade on DIII-D for Full Multi-Scale Measurements (2016-2020) (Final Report)

This report describes the first twenty-five years of development and use of the Phase Contrast Imaging (PCI) diagnostic for measuring plasma fluctuations on the DIII–D tokamak. One of the key challenges in moving tokamak technology forward to the stage of a nuclear reactor remains understanding how energy and particles are transported across the magnetic field by the action of turbulence and waves, and PCI provides a highly flexible and capable measurement of these fluctuations. The PCI diagnostic uses a laser beam to probe the plasma and optical filtering to produce an amplitude variation on a linear detector array which provides an image of the density waves in the plasma. The PCI covers an exceptional range in frequency and wavelength of the measured fluctuations, allowing observation of plasma-sized magnetohydrodynamic (MHD) modes and ion- and electron-scale turbulence. Modulation of the beam amplitude allows measurement of radio frequency (RF) waves.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗