Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

The increase in animal mortality risk following exposure to sparsely ionizing radiation is not linear quadratic with dose

The US government regulates allowable radiation exposures relying, in large part, on the seventh report from the committee to estimate the Biological Effect of Ionizing Radiation (BEIR VII), which estimated that most contemporary exposures- protracted or low-dose, carry 1.5 fold less risk of carcinogenesis and mortality per Gy than acute exposures of atomic bomb survivors. This correction is known as the dose and dose rate effectiveness factor for the life span study of atomic bomb survivors (DDREF LSS ). As a result, it was calculated by applying a linear-quadratic dose response model to data from Japanese atomic bomb survivors and a limited number of animal studies.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Development of Metallic Magnetic Calorimeters for Nuclear Safeguards Applications

Many nuclear safeguards applications could benefit from high-resolution gamma-ray spectroscopy achievable with metallic magnetic calorimeters. This dissertation covers the development of a system for these applications based on gamma-ray detectors developed at the University of Heidelberg. It demonstrates new calorimeters of this type, which achieved an energy resolution of 45.5 eV full-width at half-maximum at 59.54 keV, roughly ten times better than current state of the art high purity germanium detectors. This is the best energy resolution achieved with a gamma-ray metallic magnetic calorimeter at this energy to date. In addition to demonstrating a new benchmark in energy resolution, an experimental system for measuring samples with metallic magnetic calorimeters was constructed at Lawrence Livermore National Laboratory. This system achieved an energy resolution of 91.3 eV full-width at half-maximum at 59.54 keV under optimal conditions. Using this system it was possible to characterize the linearity of the response, the count-rate limitations, and the energy resolution as a function of temperature of the new calorimeter. With this characterization it was determined that it would be feasible to measure 242Pu in a mixed isotope plutonium sample. A measurement of a mixed isotope plutonium sample was performed over the course of 12 days with a single two-pixel metallic magnetic calorimeter. The relative concentration of 242Pu in comparison to other plutonium isotopes was determined by direct measurement to less than half a percent accuracy. This is comparable with the accuracy of the best-case scenario using traditional indirect methods. The ability to directly measure the relative concentration of 242Pu in a sample could enable more accurate accounting and detection of indications of undeclared activities in nuclear safeguards, a better constraint on source material in forensic samples containing plutonium, and improvements in verification in a future plutonium disposition treaty.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Kinetic Modeling and Experimental Studies of Capacitively Coupled Macro- and Microplasmas at Microwave Frequencies

The effect of driving frequency in the range of 13.56 MHz to 73 MHz on electron energy distribution and electron heating modes in a 50 mTorr capacitively coupled argon plasma discharge is studied using 1D-3V particle-in-cell simulations. Calculated electron energy probability functions exhibit three distinct temperatures for low-, mid-, and high-energy electrons at all the studied driving frequencies. When compared to published experimental data, the calculated probability functions show a reasonable agreement for the energy range resolved in the measurements (about 2 eV to 10 eV). Discrepancies due to limitations in experimental energy resolution outside this range lead to differences between computational and experimental values of the electron number density determined from the distribution functions, and the predicted effective electron temperature is within 25 % of experimental values. The impedance of the discharge is interpreted in terms of a homogeneous equivalent circuit model and the driving frequency dependence of the inferred combined sheath thickness is found to obey a known, theoretically-derived, power law. The average power transferred from the field to the electrons (electron heating) is computed, and a region of negative heating near the sheath edge, particularly at higher driving frequencies, is identified. Analysis of the electron momentum equation shows that electron inertia, which on temporal averaging would be zero in a linear regime, is responsible for negative values of power deposition near the sheath edge at high driving frequencies due to the highly nonlinear behavior of the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary results on an H-alpha map of the Gum nebula obtained with the D-z-A satellite

Hydrogen emissions, including telluric H alpha, in the terrestrial atmosphere were studied. The H alpha experiment was designed to use a monochromatic photometer that would provide measurements of weak H alpha emission originating at altitudes of a few hundred or thousand km, free of contamination by other telluric emissions. The Gum nebula was recorded by the instrument as a much more intense feature than the geocoronal emission. The spacecraft employed and the optical onboard equipment are described. Field of view, spectral response, absolute calibration, linearity, and inflight performance are discussed.

Blamont, J. E.↗

A multiloop approach to modeling motion sensor responses

By using a least squares identification algorithm, a multiloop approach is taken to effectively model the response characteristics of the motion sensors. The inputs to the model include the possible sources of information provided to the human via his motion sensing system. One input models the response of the angular acceleration sensors (second derivative of position) and the second input models the response of the linear sensors (sine of position). The third input is the visual display error provided to the human in the closed loop tracking experiment. Data from a roll axis tracking simulation were analyzed. The major source of pilot lead under the motion mode of operation is discussed for control of plants in which motion information improved performance and in which there was no improvement in performance.

Junker, A. M.↗

Visual search in a forced-choice paradigm

The processing of visual information was investigated in the context of two visual search tasks. The first was a forced-choice task in which one of two alternative letters appeared in a visual display of from one to five letters. The second task included trials on which neither of the two alternatives was present in the display. Search rates were estimated from the slopes of best linear fits to response latencies plotted as a function of the number of items in the visual display. These rates were found to be much slower than those estimated in yes-no search tasks. This result was interpreted as indicating that the processes underlying visual search in yes-no and forced-choice tasks are not the same.

Holmgren, J. E.↗

Digital adaptive control of a VTOL aircraft

A technique has been developed for calculating feedback and feedforward gain matrices that stabilize a VTOL aircraft while enabling it to track input commands of forward and vertical velocity. Leverrier's algorithm is used in a procedure for determining a set of state variable, feedback gains that force the closed loop poles and zeroes of one pilot input transfer function to be at preselected positions in the s plane. This set of feedback gains is then used to calculate the feedback and feedforward gains for the velocity command controller. The method is computationally attractive since the gains are determined by solving systems of linear, simultaneous equations. Responses obtained using a digital simulation of the longitudinal dynamics of the CH-47 helicopter are presented.

Reid, G. F.↗

Shape optimization of pressure gradient microphones

Recently developed finite element computer programs were utilized to investigate the influence of the shape of a body on its scattering field with the aim of determining the optimal shape for a Pressure Gradient Microphone (PGM). Circular cylinders of various aspect ratios were evaluated to choose the length to diameter ratio best suited for a dual element PGM application. Alterations of the basic cylindrical shape by rounding the edges and recessing at the centerline were also studied. It was found that for a + or - 1 db deviation from a linear pressure gradient response, a circular cylinder of aspect ratio near 0.5 was most suitable, yielding a useful upper frequency corresponding to ka = 1.8. The maximum increase in this upper frequency limit obtained through a number of shape alterations was only about 20 percent. An initial experimental evaluation of a single element cylindrical PGM of aspect ratio 0.18 utilizing a piezoresistive type sensor was also performed and is compared to the analytical results.

Norum, T. D.↗

Radiometric correction procedure study

A comparison of MSS radiometric processing techniques identified as a preferred radiometric processing technique a procedure which equalizes the mean and standard deviation of detector-specific histograms of uncalibrated scene data. Evaluation of MSS calibration data demonstrated that the relationship between detector responses is essentially linear over the range of intensities typically observed in MSS data, and that the calibration wedge data possess a high degree of temporal stability. An analysis of the preferred radiometric processing technique showed that it could be incorporated into the MDP-MSS system without a major redesign of the system, and with minimal impact on system throughput.

Colby, C.↗

Space applications of superconductivity - Low frequency superconducting sensors

Although this paper deals with several low-frequency instruments and devices, most of the discussion relates to SQUID (Superconducting QUantum Interference Device) magnetometers and gradiometers, since these are perceived as the instruments with the greatest potential for space applications. The discussion covers SQUID for magnetic field measurements; present state of the art of SQUID technology; ultimate potential performance; applications to magnetic measurements in space; SQUID galvanometers, voltage and current sensors, and wide-band amplifiers; magnetic shielding, and superconducting dc transformer. SQUIDS are superior to all other magnetic sensors in sensitivity, frequency response, range, and linearity. It is suggested that SQUID instruments, both magnetometers and gradiometers, would be valuable in studies of the dynamics of interplanetary and planetary fields. SQUID gradiometers are useful for detection and mapping of magnetic anomalies at short to moderate ranges.

Zimmerman, J. E.↗

Preliminary Geologic/spectral Analysis of LANDSAT-4 Thematic Mapper Data, Wind River/bighorn Basin Area, Wyoming

A LIDQA evaluation for geologic applications of a LANDSAT TM scene covering the Wind River/Bighorn Basin area, Wyoming, is examined. This involves a quantitative assessment of data quality including spatial and spectral characteristics. Analysis is concentrated on the 6 visible, near infrared, and short wavelength infrared bands. Preliminary analysis demonstrates that: (1) principal component images derived from the correlation matrix provide the most useful geologic information. To extract surface spectral reflectance, the TM radiance data must be calibrated. Scatterplots demonstrate that TM data can be calibrated and sensor response is essentially linear. Low instrumental offset and gain settings result in spectral data that do not utilize the full dynamic range of the TM system.

Lang, H. R.↗

Application of a linearized unsteady aerodynamic analysis to standard cascade configurations

A linearized potential flow analysis, which accounts for the effects of nonuniform steady flow phenomena on the linearized unsteady aerodynamic response to prescribed blade motions, has been applied to five cascade configurations. These include the first, fifth, eighth and ninth standard configurations proposed as a result of the Second International Symposium on Aeroelasticity in Turbomachines and a NASA Lewis flutter cascade. Selected results from this study, including comparisons between analytical predictions and the experimental measurements submitted for three of the foregoing configurations, are described. The correlation between theory and experiment for the first standard configuration (a compressor cascade operating at low Mach number and frequency) is quite good. Moreover, the predictions and measurements for the NASA Lewis cascade of symmetric biconvex airfoils show good qualitative agreement. However, wide discrepancies exist between the theoretical predictions and the experimental measurements for the fifth standard configuration (a subsonic transonic fan tip cascade). These can be partially attributed to conditions being imposed in the experiment which differ from those commonly used in unsteady aerodynamic analyses.

Verdon, J. M.↗

Device for rapid quantification of human carotid baroreceptor-cardiac reflex responses

A new device has been designed, constructed, and evaluated to characterize the human carotid baroreceptor-cardiac reflex response relation rapidly. This system was designed for study of reflex responses of astronauts before, during, and after space travel. The system comprises a new tightly sealing silicon rubber neck chamber, a stepping motor-driven electrodeposited nickel bellows pressure system, capable of delivering sequential R-wave-triggered neck chamber pressure changes between +40 and -65 mmHg, and a microprocessor-based electronics system for control of pressure steps and analysis and display of responses. This new system provokes classic sigmoid baroreceptor-cardiac reflex responses with threshold, linear, and saturation ranges in most human volunteers during one held expiration.

Sprenkle, J. M.↗

Output time response approximation

The approximation of the output response of a nonlinear system by the output response of a linear system to a desired order irrespective of the admissible input applied should prove useful for purposes of control generation and simulation. Given a nonlinear system, an integer k, and an open subset of state space, sufficient conditions are stated that such a linear approximation exists to order k for every point in the set. In addition, a method for finding the approximating linear systems is presented.

Hunt, L. R.↗