Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linearization error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Comparison of On-Orbit Performance of Rate Sensing Gyroscopes

This work presents results from the study of a large volume of spacecraft flight data pertaining to gyroscope performance. We have examined long and short term trends of gyroscope biase of first, an exact solution for the time-dependence of the attitude part of the state error covariance, averaged over the three spacecraft axes, is given. This solution is more complete than the usual cubic polynomial for the variance in that it includes coupling among the three gyroscope axes and includes an important term arising from the initial correlations. Second, several continuous 24-hour spans of gyroscope data are examined to verify the short-term statistical model. This analysis demonstrates that in-flight data can be used to determine the strength of the white noise driving the random walk of the gyroscope bias. This may be useful for postlaunch improvement to the noise model and for diagnosing the health of the gyroscope. Third, the long-term trends in gyroscope biases show a nearly linear systematic variation over time scales of years. This has been found on three different missions. While the random walk model is adequate as a basis for onboard Kalman filters or for state estimation using relatively short time spans, these trends indicate that some applications could benefit by accounting for the secular changes in the biases. One example is a new gyroscope calibration method that is under development that allows for multi-epoch bias solutions.

Sedlak, Joseph↗

Maximum likelihood method for estimating airplane stability and control parameters from flight data in frequency domain

A frequency domain maximum likelihood method is developed for the estimation of airplane stability and control parameters from measured data. The model of an airplane is represented by a discrete-type steady state Kalman filter with time variables replaced by their Fourier series expansions. The likelihood function of innovations is formulated, and by its maximization with respect to unknown parameters the estimation algorithm is obtained. This algorithm is then simplified to the output error estimation method with the data in the form of transformed time histories, frequency response curves, or spectral and cross-spectral densities. The development is followed by a discussion on the equivalence of the cost function in the time and frequency domains, and on advantages and disadvantages of the frequency domain approach. The algorithm developed is applied in four examples to the estimation of longitudinal parameters of a general aviation airplane using computer generated and measured data in turbulent and still air. The cost functions in the time and frequency domains are shown to be equivalent; therefore, both approaches are complementary and not contradictory. Despite some computational advantages of parameter estimation in the frequency domain, this approach is limited to linear equations of motion with constant coefficients.

Klein, V.↗

Variational objective analyses for cyclone studies

The basic analysis equations, i.e., the two horizontal momentum equations, the hydrostatic equation, and the integrated continuity equation were derived for the nonlinear vertical coordinate, nondimensionalized, and expressed in finite differences on a staggered grid. Special care was taken to transform the hydrostatic equation and the pressure gradient terms of the horizontal momentum equations to nearly eliminate truncation error over steeply sloping terrain. This formulation also eliminated explicit reference to orographically induced variations in the thermodynamic variables so that the variational adjustments are on the scale of the meteorological perturbations. The analysis equations were subjected to the Euler-Lagrange operations as expressed for finite differences and an additional set of five partial differential equations was derived, bringing to nine the number of equations in Model I. Higher order terms, terms containing observed quantities, and terms containing none of the variables to be adjusted were grouped into forcing functions and the equations were solved for the zero order terms. Zero order variables were eliminated between these equations and there resulted two diagnostic equations which take the form of general linear second order partial differential equations with nonconstant coefficients.

Achtemeier, G. L.↗

A laboratory verification sensor

The use of a variant of the Hartmann test is described to sense the coalignment of the 36 primary mirror segments of the Keck 10-meter Telescope. The Shack-Hartmann alignment camera is a surface-tilt-error-sensing device, operable with high sensitivity over a wide range of tilt errors. An interferometer, on the other hand, is a surface-height-error-sensing device. In general, if the surface height error exceeds a few wavelengths of the incident illumination, an interferogram is difficult to interpret and loses utility. The Shack-Hartmann aligment camera is, therefore, likely to be attractive as a development tool for segmented mirror telescopes, particularly at early stages of development in which the surface quality of developmental segments may be too poor to justify interferometric testing. The constraints are examined which would define the first-order properties of a Shack-Hartmann alignment camera and the precision and range of measurement one could expect to achieve with it are investigated. Fundamental constraints do arise, however, from consideration of geometrical imaging, diffraction, and the density of sampling of images at the detector array. Geometrical imagining determines the linear size of the image, and depends on the primary mirror diameter and the f-number of a lenslet. Diffraction is another constraint; it depends on the lenslet aperture. Finally, the sampling density at the detector array is important since the number of pixels in the image determines how accurately the centroid of the image can be measured. When these factors are considered under realistic assumptions it is apparent that the first order design of a Shack-Hartmann alignment camera is completely determined by the first-order constraints considered, and that in the case of a 20-meter telescope with seeing-limited imaging, such a camera, used with a suitable detector array, will achieve useful precision.

Vaughan, Arthur H.↗

Multi-level modulation codes and multi-stage decoding

Multi-level method is a powerful technique for constructing bandwidth efficient modulation codes. It allows the construction of modulation codes systematically with arbitrary large minimum squared Euclidean distance from component codes in conjunction with proper bits-to-signal mapping. If the component codes are chosen properly, the resultant modulation code not only has good minimum squared Euclidean distance but is also rich in structural properties such as: linear structure, phase invariant property, and trellis structure. A modulation code with linear structure has invariant distance distribution. Phase invariant property is useful in resolving carrier-phase ambiguity and ensuring rapid carrier-phase resynchronization after temporary loss of synchronization. It the component codes have trellis structure, the resultant multi-level modulation code also has trellis structure. Trellis structure allows decoding of a multi-level modulation code with the soft-decision Viterbi decoding algorithm. Furthermore, the multi-level structure allows decoding of a multi-level modulation code with the multi-stage decoding. This type of decoding reduces the decoding complexity. Multi-stage decoding is not optimum even though the decoding of each component is optimum. Based on the analysis and simulation results, the difference in error performance between the optimum decoding of the overall multi-level modulation code and the suboptimum multi-stage decoding of the code is very little, a fraction of dB loss.

Lin, Shu↗

Optimized Trajectory Correction Burn Placement for the NASA Artemis II Mission

The NASA Artemis II mission represents the first time humans plan to return to the lunar vicinity in over 50 years with a crew traveling to the Moon in the Orion spacecraft on a free return trajectory. This first crewed mission of the Artemis program will evaluate human-rated elements of Orion in preparation to sending astronauts to the lunar surface. The selected free-return cislunar trajectory profile that is reminiscent of the Apollo 8 mission that nominally requires no additional translational burns following the trans-lunar injection (TLI) burn. Due to crew activity, maneuver execution errors, navigation uncertainty, orbit insertion errors, disturbance accelerations, and other system limitations; periodic trajectory corrections burns are necessary to ensure proper entry interface (EI) conditions are satisfied for a safe return to Earth. Robust trajectory optimization techniques are utilized to determine the optimized placements for the Artemis II trajectory correction burns that accounts for the crew schedule, both the primary and backup navigation systems, targeting strategies and burn plan configurations, spacecraft venting, thruster selection, and the integrated GN&C performance.

Linear Covariance Analysis↗

Relation between perception of vertical axis rotation and vestibulo-ocular reflex symmetry

Subjects seated in a vertical axis rotation chair controlled their rotational velocity by adjusting a potentiometer. Their goal was to null out pseudorandom rotational perturbations in order to remain perceptually stationary. Most subjects showed a slow linear drift of velocity (a constant acceleration) to one side when they were deprived of an earth-fixed visual reference. The amplitude and direction of this drift can be considered a measure of a static bias in the subject's perception of rotation. The presence of a perceptual bias is consistent with a small, constant imbalance of vestibular function which could be of either central or peripheral origin. Deviations from perfect vestibulocular reflex (VOR) symmetry are also assumed to be related to imbalances in either peripheral or central vestibular function. Researchers looked for correlations between perceptual bias and various measures of vestibular reflex symmetry that might suggest a common source for both reflective and perceptual imbalances. No correlations were found. Measurement errors could not account for these results since repeated tests on the same subjects of both perceptual bias and VOR symmetry were well correlated.

Peterka, Robert J.↗

Assessment of MODIS Thermal Emissive Band On-Orbit Calibration

Sixteen Moderate Resolution Imaging Spectroradiometer thermal emissive bands (TEBs) cover the wavelength from 3.75 to 14.24 m. TEB calibration uses data collected from the detector responses to the onboard blackbody (BB) and space view. The BB was designed to operate either at a constant temperature for detector linear gain calibration or at temperatures varying from ambient ( 270 K) to 315 K for on-orbit characterization of nonlinear coefficients. In this paper, we assess TEB on-orbit calibration performance in two aspects: One is to review the calibration trending on the orbital, daily, and multiyear timescales, and the other is to analyze the on-orbit calibration radiance uncertainty and its impact on the calibration. The calibration trending confirms the detector response dependence on the instrument temperature. The temperature trending and prelaunch characterization provide the basis for determining the calibration radiance source temperature range and uncertainties. An analytical approach was used to assess the impacts of onboard radiance uncertainties. The BB emission uncertainty, resulting from the temperature measurement error and emissivity uncertainty, causes a calibration uncertainty up to 0.3%, a value decreasing with the band wavelength. The BB nonblackness effect is analyzed and found to be insignificant. For the band with the lowest BB emissivity, the nonblackness affects the calibration radiance by less than 0.08%. The cavity emission uncertainty and the scan-mirror emission uncertainty both cause a less than 0.1% calibration uncertainty. The analysis of the nonlinear calibration coefficient uncertainty shows that its effect on the low Earth-view brightness-temperature range varies by band and is generally insignificant.

Chang, Tiejun↗

Experimental validation study of an analytical model of discrete frequency sound propagation in closed-test-section wind tunnels

The principal objective is to assess the adequacy of linear acoustic theory with an impedence wall boundary condition to model the detailed sound field of an acoustic source in a duct. Measurements and calculations are compared of a simple acoustic source in a rectangular concrete duct lined with foam on the walls and anechoic end terminations. Measurement of acoustic pressure for twelve wave numbers provides variation in frequency and absorption characteristics of the duct walls. Close to the source, where the interference of wall reflections is minimal, correlation is very good. Away from the source, correlation degrades, especially for the lower frequencies. Sensitivity studies show little effect on the predicted results for changes in impedance boundary condition values, source location, measurement location, temperature, and source model for variations spanning the expected measurement error.

Mosher, Marianne↗

Extension of Low Dissipative High Order Hydrodynamics Schemes for MHD Equations

The objective of this paper is to extend our recently developed highly parallelizable nonlinear stable high order schemes for complex multiscale hydrodynamic applications to the viscous MHD (magnetohydrodynamic) equations. These schemes employed multiresolution wavelets as adaptive numerical dissipation controls to limit the amount and to aid the selection and/or blending of the appropriate types of dissipation to be used. The new scheme is formulated for both the conservative and non-conservative form of the MHD equations in curvi-linear grids. The three features of the present MHD scheme over existing schemes in the open literature are as follows. First, the scheme is constructed for long-time integrations of shock/turbulence/combustion magnetized flows. Available schemes are too diffusive for long-time integrations and/or turbulence/combustion problems. Second, unlike existing schemes for the conservative MHD equations which suffer from ill-conditioned eigen-decompositions, the present scheme makes use of a well-conditioned eigen-decomposition to solve the conservative form of the MHD equations. This is due to, partly. the fact that the divergence of the magnetic field condition is a different type of constraint from its incompressible Navier-Stokes cousin. Third, a new approach to minimize the numerical error of the divergence free magnetic condition for high order scheme is introduced.

Yee, H. C.↗

Probing Sensitivity of Discharge Characteristics to Model Selection using Uncertainty Quantification in an aprotic Li-Oxygen Battery

Currently, there are several models in the literature, such as kinetic models, microstructural models, and mass transport models that describe a Li-air battery's discharge behavior. Many of these models are calibrated and tested at low current densities and cannot be easily transferred to high current densities. Even at low current densities, there is no quantitative method for a researcher to choose a reaction kinetic model such as classical Butler-Volmer and its derivatives, and modified Marcus-Hush-Chidsey, a resistance model for lithium peroxide such as electron transport via tunneling or linear resistivity, a surface coverage model (lithium peroxide growth) such as partial coverage or full coverage, and mass transport model (discussed in Ref. [1]). Also, it is time-consuming to test different models at high current density (1C) due to a lack of well-tested models and well-calibrated model parameters. For this presentation, we will develop an analytical model, which acts as a surrogate model for a sophisticated finite element model to predict discharge time and discharge voltage. Next, we use an uncertainty quantifying technique called reduced-order stochastic optimization [2, 3] to determine the uncertainty in model parameters for rate kinetics, lithium peroxide resistivity, and parasitic resistance. Finally, a finite element simulation is performed to determine the error introduced by the surrogate model and its influence on the uncertainty in the model parameters.

M Mehta↗

Relation between perception of vertical axis rotation and vestibulo-ocular reflex symmetry

Subjects seated in a vertical axis rotation chair controlled their rotational velocity by adjusting a potentiometer. Their goal was to null out pseudorandom rotational perturbations in order to remain perceptually stationary. Most subjects showed a slow linear drift of velocity (a constant acceleration) to one side when they were deprived of an earth-fixed visual reference. The amplitude and direction of this drift can be considered a measure of a static bias in the subject's perception of rotation. The presence of a perceptual bias is consistent with a small, constant imbalance of vestibular function which could be of either central or peripheral origin. Deviations from perfect vestibulo-ocular reflex (VOR) symmetry are also assumed to be related to imbalances in either peripheral or central vestibular function. Researchers looked for correlations between perceptual bias and various measures of vestibular reflex symmetry that might suggest a common source for both reflective and perceptual imbalances. No correlations were found. Measurement errors could not account for these results since repeated tests on the same subjects of both perceptual bias and VOR symmetry were well correlated.

Peterka, Robert J.↗

The Linear Bicharacteristic Scheme for Electromagnetics

The upwind leapfrog or Linear Bicharacteristic Scheme (LBS) has previously been implemented and demonstrated on electromagnetic wave propagation problems. This paper extends the Linear Bicharacteristic Scheme for computational electromagnetics to model lossy dielectric and magnetic materials and perfect electrical conductors. This is accomplished by proper implementation of the LBS for homogeneous lossy dielectric and magnetic media and for perfect electrical conductors. Heterogeneous media are modeled through implementation of surface boundary conditions and no special extrapolations or interpolations at dielectric material boundaries are required. Results are presented for one-dimensional model problems on both uniform and nonuniform grids, and the FDTD algorithm is chosen as a convenient reference algorithm for comparison. The results demonstrate that the explicit LBS is a dissipation-free, second-order accurate algorithm which uses a smaller stencil than the FDTD algorithm, yet it has approximately one-third the phase velocity error. The LBS is also more accurate on nonuniform grids.

Beggs, John H.↗

Linear FMCW Laser Radar for Precision Range and Vector Velocity Measurements

An all fiber linear frequency modulated continuous wave (FMCW) coherent laser radar system is under development with a goal to aide NASA s new Space Exploration initiative for manned and robotic missions to the Moon and Mars. By employing a combination of optical heterodyne and linear frequency modulation techniques and utilizing state-of-the-art fiber optic technologies, highly efficient, compact and reliable laser radar suitable for operation in a space environment is being developed. Linear FMCW lidar has the capability of high-resolution range measurements, and when configured into a multi-channel receiver system it has the capability of obtaining high precision horizontal and vertical velocity measurements. Precision range and vector velocity data are beneficial to navigating planetary landing pods to the preselected site and achieving autonomous, safe soft-landing. The all-fiber coherent laser radar has several important advantages over more conventional pulsed laser altimeters or range finders. One of the advantages of the coherent laser radar is its ability to measure directly the platform velocity by extracting the Doppler shift generated from the motion, as opposed to time of flight range finders where terrain features such as hills, cliffs, or slopes add error to the velocity measurement. Doppler measurements are about two orders of magnitude more accurate than the velocity estimates obtained by pulsed laser altimeters. In addition, most of the components of the device are efficient and reliable commercial off-the-shelf fiber optic telecommunication components. This paper discusses the design and performance of a second-generation brassboard system under development at NASA Langley Research Center as part of the Autonomous Landing and Hazard Avoidance (ALHAT) project.

Pierrottet, Diego↗

High Spectral Resolution Lidar – Generation 2 (HSRL-2) Retrievals of Ocean Surface Wind Speed: Methodology and Evaluation

Ocean surface wind speed (i.e., wind speed 10 m above sea level) is a critical parameter used by atmospheric models to estimate the state of the marine atmospheric boundary layer (MABL). Accurate surface wind speed measurements in diverse locations are required to improve characterization of MABL dynamics and assess how models simulate large-scale phenomena related to climate change and global weather patterns. To provide these measurements, this study introduces and evaluates a new surface wind speed data product from the NASA Langley Research Center nadir-viewing High Spectral Resolution Lidar – generation 2 (HSRL-2) using data collected as part of the NASA Aerosol Cloud meTeorology Interactions oVer the western ATlantic Experiment (ACTIVATE) mission. The HSRL-2 can directly measure vertically resolved aerosol backscatter and extinction profiles without additional constraints or assumptions, enabling the instrument to accurately derive atmospheric attenuation and directly determine surface reflectance (i.e., surface backscatter). Also, the high horizontal spatial resolution of the HSRL-2 retrievals (0.5 s or ∼ 75 m along track) allows the instrument to probe the fine-scale spatial variability in surface wind speeds over time along the flight track and over breaks in broken cloud fields. A rigorous evaluation of these retrievals is performed by comparing coincident HSRL-2 and National Center for Atmospheric Research (NCAR) Airborne Vertical Atmosphere Profiling System (AVAPS) dropsonde data, owing to the joint deployment of these two instruments on the ACTIVATE King Air aircraft. These comparisons show correlations of 0.89, slopes of 1.04 and 1.17, and y intercepts of −0.13 and −1.05 m s−1 for linear and bisector regressions, respectively, and the overall accuracy is calculated to be 0.15 ± 1.80 m s−1. It is also shown that the dropsonde surface wind speed data most closely follow the HSRL-2 distribution of wave slope variance using the distribution proposed by Hu et al. (2008) rather than the ones proposed by Cox and Munk (1954) and Wu (1990) for surface wind speeds below 7 m s−1, with this category comprising most of the ACTIVATE data set. The retrievals are then evaluated separately for surface wind speeds below 7 m s−1 and between 7 and 13.3 m s−1 and show that the HSRL-2 retrieves surface wind speeds with a bias of ∼ 0.5 m s−1 and an error of ∼ 1.5 m s−1, a finding not apparent in the cumulative comparisons. Also, it is shown that the HSRL-2 retrievals are more accurate in the summer (−0.18 ± 1.52 m s−1) than in the winter (0.63 ± 2.07 m s−1), but the HSRL-2 is still able to make numerous (N=236) accurate retrievals in the winter. Overall, this study highlights the abilities and assesses the performance of the HSRL-2 surface wind speed retrievals, and it is hoped that further evaluation of these retrievals will be performed using other airborne and satellite data sets.

Sanja Dmitrovic↗

Precise Stabilization of the Optical Frequency of WGMRs

Crystalline whispering gallery mode resonators (CWGMRs) made of crystals with axial symmetry have ordinary and extraordinary families of optical modes. These modes have substantially different thermo-refractive constants. This results in a very sharp dependence of differential detuning of optical frequency on effective temperature. This frequency difference compared with clock gives an error signal for precise compensation of the random fluctuations of optical frequency. Certain crystals, like MgF2, have turnover points where the thermo-refractive effect is completely nullified. An advantage for applications using WGMRs for frequency stabilization is in the possibility of manufacturing resonators out of practically any optically transparent crystal. It is known that there are crystals with negative and zero thermal expansion at some specific temperatures. Doping changes properties of the crystals and it is possible to create an optically transparent crystal with zero thermal expansion at room temperature. With this innovation s stabilization technique, the resultant WGMR will have absolute frequency stability The expansion of the resonator s body can be completely compensated for by nonlinear elements. This results in compensation of linear thermal expansion (see figure). In three-mode, the MgF2 resonator, if tuned at the turnover thermal point, can compensate for all types of random thermal-related frequency drift. Simplified dual-mode method is also available. This creates miniature optical resonators with good short- and long-term stability for passive secondary frequency ethalon and an active resonator for active secondary frequency standard (a narrowband laser with long-term stability).

Savchenkov, Anatoliy↗

Performance Bounds on Two Concatenated, Interleaved Codes

A method has been developed of computing bounds on the performance of a code comprised of two linear binary codes generated by two encoders serially concatenated through an interleaver. Originally intended for use in evaluating the performances of some codes proposed for deep-space communication links, the method can also be used in evaluating the performances of short-block-length codes in other applications. The method applies, more specifically, to a communication system in which following processes take place: At the transmitter, the original binary information that one seeks to transmit is first processed by an encoder into an outer code (Co) characterized by, among other things, a pair of numbers (n,k), where n (n > k)is the total number of code bits associated with k information bits and n k bits are used for correcting or at least detecting errors. Next, the outer code is processed through either a block or a convolutional interleaver. In the block interleaver, the words of the outer code are processed in blocks of I words. In the convolutional interleaver, the interleaving operation is performed bit-wise in N rows with delays that are multiples of B bits. The output of the interleaver is processed through a second encoder to obtain an inner code (Ci) characterized by (ni,ki). The output of the inner code is transmitted over an additive-white-Gaussian- noise channel characterized by a symbol signal-to-noise ratio (SNR) Es/No and a bit SNR Eb/No. At the receiver, an inner decoder generates estimates of bits. Depending on whether a block or a convolutional interleaver is used at the transmitter, the sequence of estimated bits is processed through a block or a convolutional de-interleaver, respectively, to obtain estimates of code words. Then the estimates of the code words are processed through an outer decoder, which generates estimates of the original information along with flags indicating which estimates are presumed to be correct and which are found to be erroneous. From the perspective of the present method, the topic of major interest is the performance of the communication system as quantified in the word-error rate and the undetected-error rate as functions of the SNRs and the total latency of the interleaver and inner code. The method is embodied in equations that describe bounds on these functions. Throughout the derivation of the equations that embody the method, it is assumed that the decoder for the outer code corrects any error pattern of t or fewer errors, detects any error pattern of s or fewer errors, may detect some error patterns of more than s errors, and does not correct any patterns of more than t errors. Because a mathematically complete description of the equations that embody the method and of the derivation of the equations would greatly exceed the space available for this article, it must suffice to summarize by reporting that the derivation includes consideration of several complex issues, including relationships between latency and memory requirements for block and convolutional codes, burst error statistics, enumeration of error-event intersections, and effects of different interleaving depths. In a demonstration, the method was used to calculate bounds on the performances of several communication systems, each based on serial concatenation of a (63,56) expurgated Hamming code with a convolutional inner code through a convolutional interleaver. The bounds calculated by use of the method were compared with results of numerical simulations of performances of the systems to show the regions where the bounds are tight (see figure).

Moision, Bruce↗

Laser Metrology for an Optical-Path-Length Modulator

Laser gauges have been developed to satisfy requirements specific to monitoring the amplitude of the motion of an optical-path-length modulator that is part of an astronomical interferometer. The modulator includes a corner-cube retroreflector driven by an electromagnetic actuator. During operation of the astronomical interferometer, the electromagnet is excited to produce linear reciprocating motion of the corner-cube retroreflector at an amplitude of 2 to 4 mm at a frequency of 250, 750, or 1,250 Hz. Attached to the corner-cube retroreflector is a small pick-off mirror. To suppress vibrations, a counterweight having a mass equal to that of the corner-cube retroreflector and pick-off mirror is mounted on another electromagnetic actuator that is excited in opposite phase. Each gauge is required to measure the amplitude of the motion of the pick-off mirror, assuming that the motions of the pick-off mirror and the corner-cube retroreflector are identical, so as to measure the amplitude of motion of the corner- cube retroreflector to within an error of the order of picometers at each excitation frequency. Each gauge is a polarization-insensitive heterodyne interferometer that includes matched collimators, beam separators, and photodiodes (see figure). The light needed for operation of the gauge comprises two pairs of laser beams, the beams in each pair being separated by a beat frequency of 80 kHz. The laser beams are generated by an apparatus, denoted the heterodyne plate, that includes stabilized helium-neon lasers, acousto-optical modulators, and associated optical and electronic subsystems. The laser beams are coupled from the heterodyne plate to the collimators via optical fibers.

Gursel, Yekta↗