Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNET SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Direct Observation of Room–Temperature Magnetic Skyrmion Motion Driven by Ultra–Low Current Density in Van Der Waals Ferromagnets

The recent discovery of room-temperature ferromagnetism in 2D van der Waals (vdW) materials, such as Fe 3 GaTe 2 (FGaT), has garnered significant interest in offering a robust platform for 2D spintronic applications. Various fundamental operations essential for the realization of 2D spintronics devices are experimentally confirmed using these materials at room temperature, such as current-induced magnetization switching or tunneling magnetoresistance. Nevertheless, the potential applications of magnetic skyrmions in FGaT systems at room temperature remain unexplored. In this work, the current-induced generation of magnetic skyrmions in FGaT flakes employing high-resolution magnetic transmission soft X-ray microscopy is introduced, supported by a feasible mechanism based on thermal effects. Furthermore, direct observation of the current-induced magnetic skyrmion motion at room temperature in FGaT flakes is presented with ultra-low threshold current density. This work highlights the potential of FGaT as a foundation for room-temperature-operating 2D skyrmion device applications.

2D ferromagnets↗

Topological superconductivity induced by a triple- q magnetic structure

Here we demonstrate that the recently discovered triple- q (3 q ) magnetic structure, when embedded in a magnet-superconductor hybrid (MSH) system, gives rise to the emergence of topological superconductivity. We investigate the structure of chiral Majorana edge modes at domain walls, and show that they can be distinguished from trivial in-gap modes through the spatial distribution of the induced supercurrents. Finally, we show that topological superconductivity in 3 q MSH systems is a robust phenomenon that does not depend on the relative alignment of the magnetic and superconducting layers, or on the presence of electronic degrees of freedom in the magnetic layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantitative investigation of the short-range magnetic correlations in the candidate quantum spin liquid NaYbO 2

Here, we present a neutron diffraction study of NaYbO 2 , a candidate quantum spin-liquid (QSL) compound hosting a geometrically frustrated triangular lattice of magnetic Yb 3+ ions. We observe diffuse magnetic scattering that persists to at least 20 K, demonstrating the presence of short-range magnetic correlations in this system up to a relatively high-energy scale. Using a reverse Monte Carlo and magnetic pair distribution function analysis, we confirm the predominant antiferromagnetic nature of these correlations and show that the diffuse scattering data can be well described by noninteracting layers of Heisenberg or XY spins on the triangular lattice. We rule out Ising spins and short-range-ordered stripe or 120° phases as candidate ground states of NaYbO 2 . These results are consistent with a possible QSL ground state in NaYbO 2 and showcase the benefit of a combined reciprocal- and real-space analysis of materials with short-range magnetic correlations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Near-Field Magnetic Responses on ZrTe 5 through Cryogenic Magneto-THz Nano-Imaging

One manifestation of light-Weyl fermion interaction is the emergence of chiral magnetic effects under magnetic fields. Probing real space magnetic responses at terahertz (THz) scales is challenging but highly desired, as the local responses are less affected by the topologically trivial inhomogeneity that is ubiquitous in spatially averaged measurements. Here, we implement a cryogenic THz microscopy instrument under a magnetic field environment—a task only recently achieved. We explore the technical approach of this system and characterize the magnetic field’s influence on our AFM operation by statistical noise analysis. We find evidence for local near-field spatial variations in the topological semimetal ZrTe 5 up to a 5-Tesla magnetic field and obtain near-field THz spectra to discuss their implications for future studies on the chiral magnetic effect.

36 MATERIALS SCIENCE↗

INSTABILITY OF NON-UNIFORM TOROIDAL MAGNETIC FIELDS IN ACCRETION DISKS

We present a new type of instability that is expected to drive magnetohydrodynamic (MHD) turbulence from a purely toroidal magnetic field in an accretion disk. It is already known that in a differentially rotating system, the uniform toroidal magnetic field is unstable due to magnetorotational instability (MRI) under a non-axisymmetric and vertical perturbation, while it is stable under a purely vertical perturbation. Contrary to the previous study, this paper proposes an unstable mode completely confined to the equatorial plane, driven by the expansive nature of the magnetic pressure gradient force under a non-uniform toroidal field. The basic nature of this growing eigenmode, which we name “magneto-gradient driven instability,” is studied using linear analysis, and the corresponding nonlinear evolution is then investigated using two-dimensional ideal MHD simulations. Although a single localized magnetic field channel alone cannot provide sufficient Maxwell stress to contribute significantly to the angular momentum transport, we find that the mode coupling between neighboring toroidal fields under multiple localized magnetic field channels drastically generates a highly turbulent state and leads to the enhanced transport of angular momentum, which is comparable to the efficiency seen in previous studies on MRIs. This horizontally confined mode may play an important role in the saturation of an MRI through complementray growth with the toroidal MRIs and coupling with magnetic reconnection.

79 ASTRONOMY AND ASTROPHYSICS↗

Technical Note: Experimental results from a prototype high-field inline MRI-linac

Purpose: The pursuit of real-time image guided radiotherapy using optimal tissue contrast has seen the development of several hybrid magnetic resonance imaging (MRI)-treatment systems, high field and low field, and inline and perpendicular configurations. As part of a new MRI-linac program, an MRI scanner was integrated with a linear accelerator to enable investigations of a coupled inline MRI-linac system. This work describes results from a prototype experimental system to demonstrate the feasibility of a high field inline MR-linac. Methods: The magnet is a 1.5 T MRI system (Sonata, Siemens Healthcare) was located in a purpose built radiofrequency (RF) cage enabling shielding from and close proximity to a linear accelerator with inline (and future perpendicular) orientation. A portable linear accelerator (Linatron, Varian) was installed together with a multileaf collimator (Millennium, Varian) to provide dynamic field collimation and the whole assembly built onto a stainless-steel rail system. A series of MRI-linac experiments was performed to investigate (1) image quality with beam on measured using a macropodine (kangaroo) ex vivo phantom; (2) the noise as a function of beam state measured using a 6-channel surface coil array; and (3) electron contamination effects measured using Gafchromic film and an electronic portal imaging device (EPID). Results: (1) Image quality was unaffected by the radiation beam with the macropodine phantom image with the beam on being almost identical to the image with the beam off. (2) Noise measured with a surface RF coil produced a 25% elevation of background intensity when the radiation beam was on. (3) Film and EPID measurements demonstrated electron focusing occurring along the centerline of the magnet axis. Conclusions: A proof-of-concept high-field MRI-linac has been built and experimentally characterized. This system has allowed us to establish the efficacy of a high field inline MRI-linac and study a number of the technical challenges and solutions.

60 APPLIED LIFE SCIENCES↗

Influence of Chromium Doping on Electrical and Magnetic Behavior of Nd{sub 0.5}Sr{sub 0.5}MnO{sub 3} System

With a view to understand the influence of chromium doping at the Mn site on the electrical and magnetic behavior of the Nd{sub 0.5}Sr{sub 0.5}MnO{sub 3} manganite system, a series of samples were prepared by the citrate sol–gel route method. The samples were characterized structurally by XRD. A systematic investigation of electrical resistivity over a temperature range 5–300 K was carried out mainly to understand the magneto-transport behavior in these materials. Studies on the variation of magnetization with temperature over a temperature range 80–330 K were undertaken. Investigation of magnetization at different magnetic fields at two different temperatures, viz. 80 and 300 K, was also carried out. The results show that chromium doping gave typical electrical and magnetic properties. It has been concluded that the coexistence of charge ordered and ferromagnetic phases induced by chromium doping plays an important role in the low-temperature behavior of the system.

36 MATERIALS SCIENCE↗

Development of a radio frequency ion source with multi-helicon plasma injectors for neutral beam injection system of Versatile Experiment Spherical Torus

Despite of high plasma density, helicon plasma has not yet been applied to a large area ion source such as a driver for neutral beam injection (NBI) system due to intrinsically poor plasma uniformity in the discharge region. In this study, a radio-frequency (RF) ion source with multi-helicon plasma injectors for high plasma density with good uniformity has been designed and constructed for the NBI system of Versatile Experiment Spherical Torus at Seoul National University. The ion source consists of a rectangular plasma expansion chamber (120 × 120 × 120 mm{sup 3}), four helicon plasma injectors with annular permanent magnets and RF power system. Main feature of the source is downstream plasma confinement in the cusp magnetic field configuration which is generated by arranging polarities of permanent magnets in the helicon plasma injectors. In this paper, detailed design of the multi-helicon plasma injector and plasma characteristics of the ion source are presented.

43 PARTICLE ACCELERATORS↗

Incommensurate magnetic orders and topological Hall effect in the square-net centrosymmetric EuGa 2 Al 2 system

Neutron diffraction on the centrosymmetric square-net magnet EuGa 2 Al 2 reveals multiple incommensurate magnetic states (AFM1, 2, 3) in zero field. In applied field, a new magnetic phase (A) is identified from magnetization and transport measurements, bounded by two of the μ 0 H=0 incommensurate magnetic phases (AFM1, helical, and AFM3, cycloidal) with different moment orientations. Moreover, magnetotransport measurements indicate the presence of a topological Hall effect, with maximum values centered in the A phase. Together, these results render EuGa 2 Al 2 a material with noncoplanar or topological spin texture in applied field. X-ray diffraction reveals an out-of-plane (OOP) charge density wave (CDW) below T CDW ~50 K while the magnetic propagation vector lies in plane below T N =19.5 K. Together these data point to a new route to realizing in-plane noncollinear spin textures through an OOP CDW. In turn, these noncollinear spin textures may be unstable against the formation of topological spin textures in an applied field.

36 MATERIALS SCIENCE↗

Characterization of tissue magnetic susceptibility-induced distortions for MRIgRT

Purpose: MR image geometric integrity is one of the building blocks of MRI-guided radiotherapy. In particular, tissue magnetic susceptibility-induced effects are patient-dependent and their behavior is difficult to assess and predict. In this study, the authors investigated in detail the characteristics of susceptibility ({chi}) distortions in the context of MRIgRT, including the case of two common MR-linac system configurations. Methods: The magnetic field distortions were numerically simulated for several imaging parameters and anatomical sites, i.e., brain, lung, pelvis (with air pockets), and prostate. The simulation process consisted of (a) segmentation of patient CT data into susceptibility relevant anatomical volumes (i.e., soft-tissue, bone and air/lung), (b) conversion of CT data into susceptibility masks by assigning bulk {chi} values to the structures defined at (a), (c) numerical computations of the local magnetic fields by using a finite difference algorithm, and (d) generation of the geometric distortion maps from the magnetic field distributions. For each patient anatomy, the distortions were quantified at the interfaces of anatomical structures with significantly different {chi} values. The analysis was performed for two specific orientations of the external main magnetic field (B{sub 0}) characteristic to the MR-linac systems, specifically along the z-axis for a bore MR scanner and in the (x,y)-plane for a biplanner magnet. The magnetic field local perturbations were reported in ppm. The metrics used to quantify the geometric distortions were the maximum, mean, and range of distortions. The numerical simulation algorithm was validated using phantom data measurements. Results: Susceptibility-induced distortions were determined for both quadratic and patient specific geometries. The numerical simulations showed a good agreement with the experimental data. The measurements were acquired at 1.5 and 3 T and with an encoding gradient varying between 3 and 20 mT/m by using an annular phantom mimicking the water-air and water-oil {chi} interfaces. For quadratic geometries, the magnitude of field distortion increased rapidly with the size of the inhomogeneity up to about 10 mm and then tended to plateau. This trend became more evident for materials with a larger {Delta}{chi} relative to water. The simulations showed only a slight increase in the maximum distortion values when the B{sub 0} orientation was varied with regard to the shape of the {chi} inhomogeneity. In the case of patient anatomy, the largest distortion values arose at the air-soft-tissue interface. Considering the two MR-linac system configurations and comparing the field distortion values corresponding to all organ structures, the distortions tended to be larger for the biplanar magnet. The authors provide a reference table with ppm values which can be used to easily evaluate the geometric distortions for patient data as a function of B{sub 0} and the strength of the encoding gradient. Conclusions: The susceptibility distortions were quantified as a function of multiple parameters such as the {chi} inhomogeneity size and shape, the magnitude of B{sub 0} and the readout gradient, and the orientation of B{sub 0} with respect to the sample geometry. The analysis was performed for several anatomical sites and corresponding to two B{sub 0} orientations as featured by MR-linac systems.

60 APPLIED LIFE SCIENCES↗

Scale-invariant magnetic textures in the strongly correlated oxide NdNiO 3

Strongly correlated quantum solids are characterized by an inherently granular electronic fabric, with spatial patterns that can span multiple length scales in proximity to a critical point. Here, we use a resonant magnetic X-ray scattering nanoprobe with sub-100 nm spatial resolution to directly visualize the texture of antiferromagnetic domains in NdNiO 3 . Surprisingly, our measurements reveal a highly textured magnetic fabric, which we show to be robust and nonvolatile even after thermal erasure across its ordering temperature. The scale-free distribution of antiferromagnetic domains and its non-integral dimensionality point to a hitherto-unobserved magnetic fractal geometry in this system. These scale-invariant textures directly reflect the continuous nature of the magnetic transition and the proximity of this system to a critical point. The present study not only exposes the near-critical behavior in rare earth nickelates but also underscores the potential for X-ray scattering nanoprobes to image the multiscale signatures of criticality near a critical point.

36 MATERIALS SCIENCE↗

Precision inclusive Higgs physics at e+e- colliders with tracking detectors and without calorimetry

A primary goal of a future e + e - collider program will be the precision measurement of Higgs boson properties. For practical reasons it is of interest to determine the minimal set of detector specifications required to reach this and other scientific goals. Here we investigate the precision obtainable for the e + e - Zh μ + μ - X inclusive cross section and the Higgs boson mass using the di-muon recoil method, considering a detector that has only an inner tracking system within a solenoidal magnetic field, surrounded by many nuclear interaction lengths of absorbing material, and an outer muon identification system. We find that the sensitivity achievable in these measurements with such a tracking detector is only marginally reduced compared to that expected for a general purpose detector with additional electromagnetic and hadronic calorimeter systems. The difference results mainly from multi-photon backgrounds that are not as easily rejected with tracking detectors. We also comment on the prospects for an analogous measurement of the e + e - → Zh → e + e - X inclusive cross section. Finally, we study searches for light scalars utilizing the di-muon recoil method, estimating the projected reach with a tracking or general purpose detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial influence of paramagnetic molecules on magnetic tunnel junction-based molecular spintronic devices (MTJMSD)

Magnetic Tunnel Junction-Based Molecular Spintronic Devices (MTJMSDs) are potential candidates for inventing highly correlated systems. Understanding MTJMSD's magnetic behavior is essential to designing and fabricating practical devices. This paper investigates the effect of two contributing factors on MTJMSD's magnetic properties via Monte Carlo Simulation. Here, we have systematically studied coupling strengths and nature between magnetic molecules and ferromagnetic electrodes at various temperatures. We have also investigated the effect of length and thickness increase on MTJMSD temporal and spatial evolution of magnetic moment, magnetic correlation, and magnetic susceptibility. Our results showed that thermal energy increase significantly affects molecular devices.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetohydrodynamically stable plasma with supercritical current density at the axis

In this work, an analysis of magnetic perturbations in the GOL-3 experiment is given. In GOL-3, plasma is collectively heated in a multiple-mirror trap by a high-power electron beam. During the beam injection, the beam-plasma interaction maintains a high-level microturbulence. This provides an unusual radial profile of the net current (that consists of the beam current, current of the preliminary discharge, and the return current). The plasma core carries supercritical current density with the safety factor well below unity, but as a whole, the plasma is stable with q(a) ≈ 4. The net plasma current is counter-directed to the beam current; helicities of the magnetic field in the core and at the edge are of different signs. This forms a system with a strong magnetic shear that stabilizes the plasma core in good confinement regimes. We have found that the most pronounced magnetic perturbation is the well-known n = 1, m = 1 mode for both stable and disruptive regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Invariant exchange perturbation theory for multicenter systems and its application to the calculation of magnetic chains in manganites

The formalism of exchange perturbation theory is presented with regard to the general principles of constructing an antisymmetric vector with the use of the Young diagrams and tableaux in which the coordinate and spin parts are not separated. The form of the energy and wave function corrections coincides with earlier obtained expressions, which are reduced in the present paper to a simpler form of a symmetry-adapted perturbation operator, which preserves all intercenter exchange contributions. The exchange perturbation theory (EPT) formalism itself is presented in the standard form of invariant perturbation theory that takes into account intercenter electron permutations between overlapping nonorthogonal states. As an example of application of the formalism of invariant perturbation theory, we consider the magnetic properties of perovskite manganites La{sub 1/3}Ca{sub 2/3}MnO{sub 3} that are associated with the charge and spin ordering in magnetic chains of manganese. We try to interpret the experimental results obtained from the study of the effect of doping the above alloys by the model of superexchange interaction in manganite chains that is constructed on the basis of the exchange perturbation theory (EPT) formalism. The model proposed makes it possible to carry out a quantitative analysis of the effect of substitution of manganese atoms by doping elements with different electron configurations on the electronic structure and short-range order in a magnetic chain of manganites.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗