Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Optimizing and comparing laser anemometers

Comparisons can be made only if some single valued measure of the quality of each system can be defined. This concept is illustrated here by specifying the quality variable to be the measurement uncertainty in the mean velocity of a turbulent flow in the presence of a large background noise. The Fisher number is used as a figure of merit for some parts of the system. It is noted that in many cases of practical interest, the reciprocal Fisher number gives the actual variance of an estimator. Its principal advantage here is that it can be computed without detailed assumptions about the statistics of the estimated quantities. The concept of a Fisher number is related to the concept of information gain in a measurement. The variance of the measured mean velocity is expressed in terms of the uncertainty for the individual measurements, the measurement rate, and the velocity correlation time. Conditions are given under which the fringe and the two-spot anemometer are optimized.

Edwards, R. V.↗

The role of x-ray Swank factor in energy-resolving photon-counting imaging

Purpose: Energy-resolved x-ray imaging has the potential to improve contrast-to-noise ratio by measuring the energy of each interacting photon and applying optimal weighting factors. The success of energy-resolving photon-counting (EPC) detectors relies on the ability of an x-ray detector to accurately measure the energy of each interacting photon. However, the escape of characteristic emissions and Compton scatter degrades spectral information. This article makes the theoretical connection between accuracy and imprecision in energy measurements with the x-ray Swank factor for a-Se, Si, CdZnTe, and HgI{sub 2}-based detectors. Methods: For a detector that implements adaptive binning to sum all elements in which x-ray energy is deposited for a single interaction, energy imprecision is shown to depend on the Swank factor for a large element with x rays incident at the center. The response function for each converter material is determined using Monte Carlo methods and used to determine energy accuracy, Swank factor, and relative energy imprecision in photon-energy measurements. Results: For each material, at energies below the respective K edges, accuracy is close to unity and imprecision is only a few percent. Above the K-edge energies, characteristic emission results in a drop in accuracy and precision that depends on escape probability. In Si, and to some extent a-Se, Compton-scatter escape also degrades energy precision with increasing energy. The influence of converter thickness on energy accuracy and imprecision is modest for low-Z materials but becomes important when using high-Z materials at energies greater than the K-edge energies. Conclusions: Accuracy and precision in energy measurements by EPC detectors are determined largely by the energy-dependent x-ray Swank factor. Modest decreases in the Swank factor (5%-15%) result in large increases in relative imprecision (30%-40%).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interpretation of the dosimetric results of three uniformity regularization methods in terms of expected treatment outcome

In IMRT treatment plan optimization there are various methods that try to regularize the variation of dose nonuniformity using purely dosimetric measures. However, although these methods can help in finding a good dose distribution, they do not provide any information regarding the expected treatment outcome. When a treatment plan optimization is performed using biological measures, the final goal should be some indication about the expected tumor control or normal tissue complications, which is the primary goal of treatment planning (the association of treatment configurations and dose prescription with the treatment outcome). In this study, this issue is analyzed distinguishing the dose-oriented treatment plan optimization from the response-oriented optimization. Three different dose distributions were obtained by using a dose-based optimization technique, an EUD-based optimization without applying any technique for regularizing the nonuniformity of the dose distribution, and an EUD-based optimization using a variational regularization technique, which controls dose nonuniformity. The clinical effectiveness of the three dose distributions was investigated by calculating the response probabilities of the tumors and organs-at-risk (OARs) involved in two head and neck and prostate cancer cases. The radiobiological models used are the linear-quadratic-Poisson and the Relative Seriality models. Furthermore, the complication-free tumor control probability and the biologically effective uniform dose (D-bar) were used for treatment plan evaluation and comparison. The radiobiological comparison shows that the EUD-based optimization using L-curve regularization gives better results than the EUD-based optimization without regularization and dose-based optimization in both clinical cases. Concluding, it appears that the applied dose nonuniformity regularization technique is expected to improve the effectiveness of the optimized IMRT dose distributions. However, more patient cases are needed to validate the statistical significance of the results and conclusions presented in this paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimizing spin dressing sensitivity for the nEDMSF experiment

nEDMSF aims to measure the neutron electric dipole moment (d n ) with unprecedented precision. In this paper we explore the experiment's sensitivity when operating with an implementation of the critical dressing method in which the angle between the neutron and Helium-3 spins (ϕ 3n ) is subjected to a square modulation by an amount ϕ d (the “dressing angle”). Several parameters can be tuned to optimize sensitivity. We find roughly 10% improvement over a previous estimate, resulting primarily from the addition of a waiting period between the π/2 pulse that initiates d n -driven ϕ 3n growth and the start of ϕ3n modulation. We find negligible further improvement by allowing ϕ d to vary continuously over the course of a run, and no degradation resulting from the addition of an in situ background measurement into each ϕ3n modulation sequence. A complete simulation confirms a 300 live-day sensitivity ofσ = 1.45×10 -28 e ·cm. At this level of sensitivity, σ ϕ3n0 = 1 mrad precision on the initial n/ 3 He angle difference is not negligible.

47 OTHER INSTRUMENTATION↗

Characterizing the Roman Grism Redshift Efficiency of Type Ia Supernova Host Galaxies for the High-latitude Time-domain Survey

The High-latitude Time-domain Survey (HLTDS) for the Nancy Grace Roman Space Telescope (Roman) will discover thousands of high-redshift Type Ia supernovae (SNe Ia) to set generation-defining cosmological constraints on dark energy. To construct the Roman SN Hubble diagram, a strategy to obtain redshifts must be determined. While the nominal HLTDS will use only the Roman prism, in this work, we consider the utility of the Roman grism observations from overlap with the High-latitude Wide-area Survey for SN Ia cosmology. We determine a galaxy grism redshift recovery rate by simulating dispersed grism images and measuring redshifts with the Grizli software, obtaining an H-band 50% redshift recovery at magnitude 20.61 and 90% recovery at magnitude 19.27. To estimate the total number of spectroscopic redshifts expected for Roman SN cosmology, we also consider a Roman prism SN redshift efficiency and a ground-based telescope redshift efficiency for host galaxies. We apply these redshift efficiencies to SN Ia catalog-level simulations and predict that ∼6800 SNe will have an SN or host spectroscopic redshift. Second, we evaluate the size of potential systematics related to modeling the grism redshift efficiency by considering the impact of additional dependences on stellar mass and host-galaxy color. We estimate the largest potential size of this systematic to be 0.0066 ± 0.002 and −0.0266 ± 0.0079, roughly 42.9% and 49.6% of the statistical uncertainty, for w 0 and w a , respectively. Lastly, we consider the effects of assuming different redshift sources on the optimization of the HLTDS survey strategy by measuring relative changes to the dark energy figure of merit.

Chen, Rebecca C. [Duke Univ., Durham, NC (United S↗

Absorption of CO laser radiation by NO

The paper describes absorption calculations and measurements at selected infrared CO laser wavelengths which are nearly coincident with absorption lines in the fundamental vibration-rotation band of NO near 5.3 microns. Initial work was directed towards establishing the optimal CO laser-NO absorption line coincidence for high temperature applications. Measurements of the absorption coefficient at this optimal laser wavelength were carried out, first using a room-temperature absorption cell for high-temperature calculations and then using a shock tube, for the temperature range 630-4000 K, to validate the high temperature calculations.

Hanson, R. K.↗

SU-F-T-183: Design of a Beam Shaping Assembly of a Compact DD-Based Boron Neutron Capture Therapy System

Purpose: To design a beam shaping assembly (BSA) to shape the 2.45-MeV neutrons produced by a deuterium-deuterium (DD) neutron generator and to optimize the beam output for boron neutron capture therapy of brain tumors Methods: MCNP is used for this simulation study. The simulation model consists of a neutron surface source that resembles an actual DD source and is surrounded by a BSA. The neutron source emits 2.45-MeV neutrons isotropically. The BSA is composed of a moderator, reflector, collimator and filter. Various types of materials and geometries are tested for each component to optimize the neutron output. Neutron characteristics are measured with an 2×2×2-cm{sup 3} air-equivalent cylinder at the beam exit. The ideal BSA is determined by evaluating the in-air parameters, which include epithermal neutron per source neutron, fast neutron dose per epithermal neutron, and photon dose per epithermal neutron. The parameter values are compared to those recommended by the IAEA. Results: The ideal materials for reflector and thermal neutron filter were lead and cadmium, respectively. The thickness for reflector was 43 cm and for filter was 0.5 mm. At present, the best-performing moderator has 25 cm of AlF{sub 3} and 5 cm of MgF{sub 2}. This layout creates a neutron spectrum that has a peak at approximately 10 keV and produces 1.35E-4 epithermal neutrons per source neutron per cm{sup 2}. Additional neutron characteristics, fast neutrons per epithermal neutron and photon per epithermal neutron, are still under investigation. Conclusion: Working is ongoing to optimize the final layout of the BSA. The neutron spectrum at the beam exit window of the final configuration will have the maximum number of epithermal neutrons and limited photon and fast neutron contaminations within the recommended values by IAEA. Future studies will also include phantom experiments to validate the simulation results.

07 ISOTOPE AND RADIATION SOURCES↗

Optimizing Deep Geothermal Drilling for Energy Sustainability in the Appalachian Basin

This study investigates the geological and geomechanical characteristics of the MIP 1S geothermal well in the Appalachian Basin to optimize drilling and address the wellbore stability issues encountered. Data from well logs, sidewall core analysis, and injection tests were used to derive elastic and rock strength properties, as well as stress and pore pressure profiles. A robust 1D-geomechanical model was developed and validated, correlating strongly with wellbore instability observations. This revealed significant wellbore breakout, widening the diameter from 12 ¼ inches to over 16 inches. Advanced technologies like Cerebro Force™ In-Bit Sensing were used to monitor drilling performance with high accuracy. This technology tracks critical metrics such as bit acceleration, vibration in the x, y, and z directions, Gyro RPM, stick-slip indicators, and bending on the bit. Cerebro Force™ readings identified hole drag caused by poor hole conditions, including friction between the drill string and wellbore walls and the presence of cuttings or debris. This led to higher torque and weight on bit (WOB) readings at the surface compared to downhole measurements, affecting drilling efficiency and wellbore stability. Optimal drilling parameters for future deep geothermal wells were determined based on these findings.

Environmental Sciences & Ecology↗

Estimation of Sea Ice Thickness Distributions through the Combination of Snow Depth and Satellite Laser Altimetry Data

Combinations of sea ice freeboard and snow depth measurements from satellite data have the potential to provide a means to derive global sea ice thickness values. However, large differences in spatial coverage and resolution between the measurements lead to uncertainties when combining the data. High resolution airborne laser altimeter retrievals of snow-ice freeboard and passive microwave retrievals of snow depth taken in March 2006 provide insight into the spatial variability of these quantities as well as optimal methods for combining high resolution satellite altimeter measurements with low resolution snow depth data. The aircraft measurements show a relationship between freeboard and snow depth for thin ice allowing the development of a method for estimating sea ice thickness from satellite laser altimetry data at their full spatial resolution. This method is used to estimate snow and ice thicknesses for the Arctic basin through the combination of freeboard data from ICESat, snow depth data over first-year ice from AMSR-E, and snow depth over multiyear ice from climatological data. Due to the non-linear dependence of heat flux on ice thickness, the impact on heat flux calculations when maintaining the full resolution of the ICESat data for ice thickness estimates is explored for typical winter conditions. Calculations of the basin-wide mean heat flux and ice growth rate using snow and ice thickness values at the 70 m spatial resolution of ICESat are found to be approximately one-third higher than those calculated from 25 km mean ice thickness values.

Kurtz, Nathan T.↗

Robust Parameter Design on Dual Stochastic Response Models With Constrained Bayesian Optimization

In engineering system design, minimizing the variations of the quality measurements while guaranteeing their overall quality up to certain levels, namely the robust parameter design (RPD), is crucial. Recent works have dealt with the design of a system whose response-control variables relationship is a deterministic function with a complex shape and function evaluation is expensive. In this work, we propose a Bayesian optimization method for the RPD of stochastic functions. Dual stochastic response models are carefully designed for stochastic functions. The heterogeneous variance of the sample mean is addressed by the predictive mean of the log variance surrogate model in a two-step approach. We establish an acquisition function that favors exploration across the feasible and optimality-improvable regions to effectively and efficiently solve the stochastic constrained optimization problem. Further, the performance of our proposed method is demonstrated by the extensive numerical and case studies. Note to Practitioners-Many manufacturing processes involve undesirable variations, which create variations in the final products. For example, many emerging manufacturing processes, such as nanomanufacturing, involve complex physical and chemical dynamics and transformation, creating variations in the manufacturing output. In such processes, it is crucial to design the manufacturing processes or products so that they have minimum variations in their quality. Meanwhile, it is also important to maintain the overall quality of the designed processes or products. Furthermore, acquiring data from many advanced manufacturing processes is often very costly, especially in the designing stage. In this work, we propose a data-driven method that automatically finds the best setting of manufacturing processes or products with the minimum variations of quality and a given constraint on the average quality satisfied. Our proposed method is used before conducting every experiment; It analyzes the historical data from previous experiments and provides a setting to be used in the next experiment. Our proposed method efficiently utilizes the historical data, and thus finds the best robust setting by conducting only a small number of experiments.

42 ENGINEERING↗

Applications of wavelet-based compression to multidimensional Earth science data

A data compression algorithm involving vector quantization (VQ) and the discrete wavelet transform (DWT) is applied to two different types of multidimensional digital earth-science data. The algorithms (WVQ) is optimized for each particular application through an optimization procedure that assigns VQ parameters to the wavelet transform subbands subject to constraints on compression ratio and encoding complexity. Preliminary results of compressing global ocean model data generated on a Thinking Machines CM-200 supercomputer are presented. The WVQ scheme is used in both a predictive and nonpredictive mode. Parameters generated by the optimization algorithm are reported, as are signal-to-noise (SNR) measurements of actual quantized data. The problem of extrapolating hydrodynamic variables across the continental landmasses in order to compute the DWT on a rectangular grid is discussed. Results are also presented for compressing Landsat TM 7-band data using the WVQ scheme. The formulation of the optimization problem is presented along with SNR measurements of actual quantized data. Postprocessing applications are considered in which the seven spectral bands are clustered into 256 clusters using a k-means algorithm and analyzed using the Los Alamos multispectral data analysis program, SPECTRUM, both before and after being compressed using the WVQ program.

Bradley, Jonathan N.↗

Dynamically Learning Incentives for Load Control

As electrical generation becomes more distributed and volatile, and loads become more uncertain, controllability of distributed energy resources (DERs), regardless of their ownership status, will be necessary for grid reliability. Grid operators lack direct control over end-users' grid interactions, such as energy usage, but incentives can influence behavior -- for example, an end-user that receives a grid-driven incentive may adjust their consumption or expose relevant control variables in response. A key challenge in studying such incentives is the lack of data about human behavior, which usually motivates strong assumptions, such as distributional assumptions on compliance or rational utility-maximization. In this paper, we propose a general incentive mechanism in the form of a constrained optimization problem -- our approach is distinguished from prior work by modeling human behavior (e.g., reactions to an incentive) as an arbitrary unknown function. We propose feedback-based optimization algorithms to solve this problem that each leverage different amounts of information and/or measurements. We show that each converges to an asymptotically stable incentive with (near)-optimality guarantees given mild assumptions on the problem. Finally, we evaluate our proposed techniques in voltage regulation simulations on standard test beds. We test a variety of settings, including those that break assumptions required for theoretical convergence (e.g., convexity, smoothness) to capture realistic settings. In this evaluation, our proposed algorithms are able to find near-optimal incentives even when the reaction to an incentive is modeled by a theoretically difficult (yet realistic) function.

demand response↗

Measuring oxygen reduction/evolution reactions on the nanoscale

The efficiency of fuel cells and metal-air batteries is significantly limited by the activation of oxygen reduction and evolution reactions (ORR/OER). Despite the well-recognized role of oxygen reaction kinetics on the viability of energy technologies, the governing mechanisms remain elusive and until now addressable only by macroscopic studies. This lack of nanoscale understanding precludes optimization of material architecture. Here we report direct measurements of oxygen reduction/evolution reactions and oxygen vacancy diffusion on oxygen-ion conductive solid surfaces with sub-10 nanometer resolution. In electrochemical strain microscopy (ESM), the biased scanning probe microscopy tip acts as a moving, electrocatalytically active probe exploring local electrochemical activity. The probe concentrates an electric field in a nanometer-scale volume of material, and bias-induced, picometer-level surface displacements provide information on local electrochemical processes. Systematic mapping of oxygen activity on bare and Pt-functionalized yttria-stabilized zirconia (YSZ) surfaces is demonstrated. This approach allows directly visualization of ORR/OER activation process at the triple-phase boundary, and can be extended to broad spectrum of oxygen-conductive and electrocatalytic materials.

30 DIRECT ENERGY CONVERSION↗

Magnetic Microcalorimeter (MMC) Gamma Detectors with Ultra-High Energy Resolution

The goal of this LCP is to develop ultra-high resolution gamma-ray detectors based on magnetic microcalorimeters (MMCs) for accurate measurements of nuclear decay data and NDA of nuclear materials. For highest energy resolution, we are introducing erbium-doped silver (Ag:Er) as a novel sensor material and implement several geometry and design changes to improve the signal-to-noise ratio. The detector sensitivity will be increased by developing arrays of 32 Ag:Er pixels read out by 16 SQUID preamplifiers, and by developing a cryogenic Compton veto to reduce the spectral background. For highest energy resolution we will operate the MMC detector arrays in a dilution refrigerator with a base temperature <10 mK. The detector performance and utility will be demonstrated with radioactive sources of interest to the safeguards community. In FY16 and FY17, we had purchased a liquid-cryogen-free dilution refrigerator and installed 16 SQUID preamplifiers and writing for MMC detector operation at ~10 mK. We have also developed the process to fabricate the first Ag:Er-based MMCs, built prototype detector arrays and tested them with different radioactive sources. We have also shown that our MMC detectors can achieve the LCP goal of an energy resolution below 50 eV as needed to resolve most closelyspaced lines of interest for NDA. The goals for FY18 were then 1) to optimize the MMC design based on the measured detector characteristics and to increase the array size to 32-pixels for increased sensitivity, and 2) to demonstrate the utility of MMC gamma-ray detectors in applications relevant in nuclear safeguards.

42 ENGINEERING↗

Optimizing fictitious states for Bell inequality violation in bipartite qubit systems with applications to the t t ¯ system

There is a significant interest in testing quantum entanglement and Bell inequality violation in high-energy experiments. Since the analyses in high-energy experiments are performed with events statistically averaged over phase space, the states used to determine observables depend on the choice of coordinates through an event-dependent basis and are thus not genuine quantum states, but rather “fictitious states.” We find that the basis which diagonalizes the spin-spin correlations is optimal for constructing fictitious states to test the violation of Bell’s inequality. This result is applied directly to the bipartite qubit system of a top and antitop produced at a hadron collider. We show that the beam axis is the optimal basis choice near the t t ¯ threshold production for measuring Bell inequality violation, while at high transverse momentum the basis that aligns along the momentum direction of the top is optimal. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Aerogel-Positronium Technology for the Detection of Small Quantities of Organic and/or Toxic Materials

The Ps-aerogel system [Ps is positronium (an electron-positron-hydrogen-like atom)] has been evaluated and optimized as a potential tool for planetary exploration missions. Different configurations of use were assessed, and the results provide a quantitative measure of the expected performance. The aerogel density is first optimized to attain maximum production of Ps that reaches the pores of the aerogel. This has been accomplished, and the optimum aerogel density is .70 mg/cm3. The aerogel is used as a concentrator for target volatile moieties, which accumulate in its open porosity over an extended period of time. For the detection of the accumulated materials, the use of Ps as a probe for the environment at the pore surface, has been proposed. This concept is based on two steps: (1) using aerogel to produce Ps and (2) using the propensity of Ps to interact differently with organic and inorganic matter. The active area of such a detector will comprise aerogel with a certain density, specific surface area, and gas permeability optimized for Ps production and gas diffusion and adsorption. The aerogel is a natural adsorber of organic molecules, which adhere to its internal surface, where their presence is detected by the Ps probe. Initial estimates indicate that, e.g., trace organic molecules in the Martian atmosphere, can be detected at the ppm level, which rivals current methods having significantly higher complexity, volume, mass, and power consumption (e.g. Raman, IR).

Petkov, Mihail P.↗

Radionuclide Imaging Technologies for Biological Systems

The main objective of this project is to develop technologies and experimental techniques for studying the dynamics of physiological responses of plants to changes in their interface with the local environment and to educate a new generation of scientists in an interdisciplinary environment of biology, physics and engineering. Also an important goal is to perform measurements to demonstrate the new data that can be produced and made available to the plant-biology community using the imaging technologies and experimental techniques developed in this project. The study of the plant-environment interface includes a wide range of topics in plant physiology, e.g., the root-soil interface, resource availability, impact of herbivores, influence of microbes on root surface, and responses to toxins in the air and soil. The initial scientific motivation for our work is to improve understanding of the mechanisms for physiological responses to abrupt changes in the local environment, in particular, the responses that result in short-term adjustments in resource (e.g., sugars, nutrients and water) allocations. Data of time-dependent responses of plants to environmental changes are essential in developing mechanistic models for substance intake and resource allocation. Our approach is to use radioisotope tracing techniques to study whole-plant and plant organ (e.g., leaves, stems, roots) dynamical responses to abrupt changes in environmental conditions such as concentration of CO 2 in the atmosphere, nutrient availability and lighting. To this aim we are collaborating with the Radiation Detector and Imaging Group at the Thomas Jefferson National Laboratory Facility (JLab) to develop gamma-ray and beta particle imaging systems optimized for plant studies. The radioisotope tracing measurements are conducted at the Phytotron facility at Duke University. The Phytotron is a controlled environment plant research facility with a variety of plant growth chambers. One chamber is dedicated to radioisotope labeling measurements. All measurements for this project were carried out in that specially equipped chamber. The radioisotopes used in this project were produced in the tandem accelerator laboratory operated by the Triangle Universities Nuclear Laboratory (TUNL). The target room where the isotopes are produced is located about 100 m from the Phytotron facility. The radioactive substances produced in the tandem laboratory are transported to the Phytotron through underground conduits that run between the two buildings.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗