Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Measurement of H(e,e’) and D(e,e’) Cross-Sections for Bloom-Gilman Quark-Hadron Duality Study

The E12-10-002 experiment which ran in 2018 in Hall C at the Thomas Jefferson National Accelerator Facility measured the inclusive electron scattering cross-sections for hydrogen and deuterium. This was the first experiment conducted with the new Super High-Momentum Spectrometer and accompanying instrumentation. These measurements extend the previous Hall C measurements up to Q2 = 16 GeV2. This dissertation presents the analyses of the new detectors and shows the preliminary results for F2 structure function and the study of quark-hadron duality in the four nucleon-resonance regions.

Sun, Abel↗

Computation of diffuse sky irradiance from multidirectional radiance measurements

Accurate determination of the diffuse solar spectral irradiance directly above the land surface is important in characterizing the reflectance properties of these surfaces, especially vegetation canopies. This determination is also needed to infer the net radiation budget of the earth-atmosphere system above these surfaces. An algorithm is developed here for the computation of hemispheric diffuse irradiance using the measurements from an instrument called PARABOLA, which rapidly measures upwelling and downwelling radiances in three selected wavelength bands. The validity of the algorithm is established from simulations. The standard reference data set of diffuse radiances of Dave (1978), obtained by solving the radiative transfer equation numerically for realistic atmospheric models, is used to simulate PARABOLA radiances. Hemispheric diffuse irradiance is estimated from a subset of simulated radiances by using the algorithm described. The algorithm is validated by comparing the estimated diffuse irradiance with the true diffuse irradiance of the standard data set. The validations include sensitivity studies for two wavelength bands (visible, 0.65-0.67 micron; near infrared, 0.81-0.84 micron), different atmospheric conditions, solar elevations, and surface reflectances. In most cases the hemispheric diffuse irradiance computed from simulated PARABOLA radiances and the true irradiance obtained from radiative transfer calculations agree within 1-2 percent. This technique can be applied to other sampling instruments designed to estimate hemispheric diffuse sky irradiance.

Ahmad, Suraiya P.↗

Improved evaluation of safeguards parameters from spent fuel measurements with the Differential Die-Away (DDA) instrument

The Differential Die-Away (DDA) technique is a highly sensitive non-destructive assay method for characterizing and detecting the presence of fissile material within an item of interest. DDA utilizes a series of pulses from a neutron generator (NG) to actively interrogate an item of interest. The die-away time of the neutron population induced by this active interrogation and the integral of the total differential die-away signal can be used to characterize items such as nuclear waste drums and spent nuclear fuel assemblies. In this work, Los Alamos National Laboratory (LANL) conceptualized, designed, and fabricated a DDA instrument that was deployed for field test measurements at the Central Interim Storage Facility for Spent Nuclear Fuel (Clab) in Oskarshamn, Sweden. The instrument performed multiple static measurements at fixed locations and dynamic axial scans of 15 pressurized water reactor (PWR) and 10 boiling water reactor (BWR) spent fuel assemblies, collecting both passive and active measurement data. The static assays of the assemblies measured the differential die-away signal, die-away time, and total passive neutron emission rate to create calibration curves for the evaluation of assembly multiplication, burnup, initial enrichment, effective fissile mass, and total elemental plutonium mass. Each calibration curve was optimized by minimizing the relative root mean square error (RRMSE) of assembly assay results compared to declared assembly parameters. The same quantities were also measured with the axial scans, and the resulting data were applied in two ways: (1) in the creation of calibration curves to improve evaluation of the same safeguards parameters as static assays, and (2) for comparison to simulation. In most cases, across both PWR and BWR assemblies, axial scan data improved the estimation of the above parameters, quantified by decreasing the calibration curve RRMSE. These axial scan results demonstrate the ability of the DDA instrument and analysis method to characterize spent PWR and BWR fuel as well as, or better than, a static assay of the same assembly. Furthermore, the DDA instrument’s unique ability to obtain both active and passive data in a single, axial scan of an entire spent fuel assembly represents a more efficient and accurate way of assaying spent fuel for verification purposes. These results represent a significant advancement for characterizing spent nuclear fuel compared to current technologies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparing Single-Point and Multi-point Calibration Methods in Modulated DSC

Heat capacity measurements for High Density Polyethylene (HDPE) and Ultra-high Molecular Weight Polyethylene (UHMWPE) were performed using Modulated Differential Scanning Calorimetry (mDSC) over a wide temperature range, -70 to 115 °C, with a TA Instruments Q2000 mDSC. The default calibration method for this instrument involves measuring the heat capacity of a sapphire standard at a single temperature near the middle of the temperature range of interest. However, this method often fails for temperature ranges that exceed a 50 °C interval, likely because of drift or non-linearity in the instrument's heat capacity readings over time or over the temperature range. Therefore, in this study a method was developed to calibrate the instrument using multiple temperatures and the same sapphire standard.

47 OTHER INSTRUMENTATION↗

SU-E-I-51: Quantitative Assessment of X-Ray Imaging Detector Performance in a Clinical Setting - a Simple Approach Using a Commercial Instrument

Purpose: To measure and compare the performance of X-ray imaging detectors in a clinical setting using a dedicated instrument for the quantitative determination of detector performance. Methods: The DQEPro (DQE Instruments Inc., London, Ontario Canada) was used to determine the MTF, NPS and DQE using an IEC compliant methodology for three different imaging modalities: conventional radiography (CsI-based detector), general-purpose radioscopy (CsI-based detector), and mammography (a-Se based detector). The radiation qualities (IEC) RQA-5 and RQA-M-2 were used for the CsI-based and a-Se-based detectors, respectively. The DQEPro alleviates some of the difficulties associated with DQE measurements by automatically positioning test devices over the detector, guiding the user through the image acquisition process and providing software for calculations. Results: A comparison of the NPS showed that the image noise of the a-Se detector was less correlated than the CsI detectors. A consistently higher performance was observed for the a-Se detector at all spatial frequencies (MTF: 0.97@0.25 cy/mm, DQE: 0.72@0.25 cy/mm) and the DQE drops off slower than for the CsI detectors. The CsI detector used for conventional radiography displayed a higher performance at low spatial frequencies compared to the CsI detector used for radioscopy (DQE: 0.65 vs 0.60@0.25 cy/mm). However, at spatial frequencies above 1.3 cy/mm, the radioscopy detector displayed better performance than the conventional radiography detector (DQE: 0.35 vs 0.24@2.00 cy/mm). Conclusion: The difference in the MTF, NPS and DQE that was observed for the two different CsI detectors and the a-Se detector reflect the imaging tasks that the different detector types are intended for. The DQEPro has made the determination and calculation of quantitative metrics of X-ray imaging detector performance substantially more convenient and accessible to undertake in a clinical setting.

60 APPLIED LIFE SCIENCES↗

Raman Lidar (RL) Instrument Handbook

The Raman lidar at the ARM Climate Research Facility (ACRF) Southern Great Plains (SGP) Central Facility (SGPRL) is an active, ground-based laser remote sensing instrument that measures height and time resolved profiles of water vapor mixing ratio and several cloud- and aerosol-related quantities. The system is a non-commercial custom-built instrument developed by Sandia National Laboratories specifically for the ARM Program. It is fully computer automated, and will run unattended for many days following a brief (~5-minute) startup period. The self-contained system (requiring only external electrical power) is housed in a climate-controlled 8’x8’x20’ standard shipping container.

54 ENVIRONMENTAL SCIENCES↗

Topex/Poseidon satellite - Enabling a joint U.S.-French mission for global ocean study

A joint U.S./French mission, which represents a merging of the prior NASA Topex and CNES Poseidon progams, is described. The Topex/Poseidon satellite will contribute to two of the World Climate Research Program's phases: the World Ocean Circulation Experiment and the Tropical Ocean Global Atmosphere experiment. The satellite's instruments will measure the ocean currents and their variability on the global basis via satellite altimetry and precision orbit determinations. The paper describes the satellite configuration and characteristics and the mission instruments and system elements. The Topex/Poseidon's design diagrams and block diagrams are included.

Hall, Ralph L.↗

Microphone Corrections for Accurate In-Flow Acoustic Measurements at High Frequency

Acoustic analysis of aircraft components through small-scale experiments in wind tunnels requires in-flow acoustic measurements at high frequencies. This high frequency information is shifted to lower frequencies during the geometric scaling process. As a result, models of scale one tenth and smaller require frequency information of up to at least 100 kHz to resolve the midpoint of the full-scale equivalent audible range. Farfield acoustic measurements of frequencies higher than 100 kHz are prohibitively difficult to make due to the physical limitations of atmospheric propagation over large distances and the delicacy of the required instruments. Even measurements up to 100 kHz require special corrections and calibration procedures to maintain sufficient accuracy. In-flow microphone measurements at high frequencies require additional consideration due to the presence of the aerodynamic microphone forebody which protects the microphone diaphragm from flow impingement. The screen located at the forebody surface attenuates the high frequency acoustic waves and must be accounted for. The purpose of this paper is to present procedures for calibrating and correcting high frequency acoustic measurements to retain high accuracy. Specifically, this paper gives calibration procedures and examples of typical data for calibrating or correcting for five physical effects. These effects include the frequency response of the entire acoustic data acquisition system, intrusion of the microphone into the acoustic field, forebody screen attenuation, directionality of microphone forebody response and atmospheric absorption.

Allen, Christopher S.↗

Preliminary results of a balloon flight of the solar disk sextant

Preliminary results of a balloon flight on October 11, 1991, of the solar disk sextant (SDS) experiment are reported. The SDS is an instrument which measures the solar diameter at different orientations with respect to the solar polar axis. Fitting straight lines through two fixed-angle data sets with time as the independent variable yields slopes of (7.1 +/ - 1.5) x 10 exp -3 and (6.7 +/- 1.6) x 10 exp -3/mas s, consistent with the value of 6.47 x 10 exp -3/mas s expected from the earth's approach to the sun due to the orbital motion toward perihelion. Upon the instrument's rotation on its axis a sinusoidal component of the diameter measurement was observed in each rotation cycle, with a variable amplitude of about 150 mas. The present result is epsilon of (5.6 +/- 6.3) x 10 exp -6, about 30 deg offset from the polar-equator position. The absolute diameter obtained by means of the FFT definition is found to be 1919.269 +/- 0.240 arcsec or 1919.131 +/- 0.240 arcsec, depending on the orientation mode of the measurement.

Maier, E.↗

Water Vapor Isotopic Composition from the Azores Field Campaign Report

This study used one year of in situ water vapor isotopologue measurements collected at the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility observatory located on Graciosa Island, Azores. Low clouds have an especially strong feedback over the ocean and previous studies have primarily focused on low clouds in the subtropics. This means that the Azores location in the transition between subtropical and mid-latitude oceanic areas represents an opportunity to study the connection between water vapor isotopologues and mixing processes that determine low-cloud feedback in an underrepresented setting with different seasonal dynamics. The DOE ARM facility on Graciosa Island presents the opportunity to complement water vapor isotopologue measurements with a suite of instruments capable of measuring changing atmospheric conditions.

54 ENVIRONMENTAL SCIENCES↗

10min Lidar Winds/ Derived Data

This dataset contains 10-min averaged, motion-corrected wind profiles from the WindCube lidar during the deployment of the DOE WindSentinel buoy near Oahu, Hawaii. The attached Lidar Buoy Data Dictionary provides further details on the various instruments on the buoy, parameters measured by each instrument, and the frequency of data collection.

17 WIND ENERGY↗

1Hz Lidar Winds / Reviewed Data

This dataset contains 1Hz, motion-corrected wind profiles from the WindCube lidar during the deployment of the DOE WindSentinel buoy near Oahu, Hawaii. The attached Lidar Buoy Data Dictionary provides further details on the various instruments on the buoy, parameters measured by each instrument, and the frequency of data collection.

17 WIND ENERGY↗

Joint Conference on Sensing of Environmental Pollutants, 2nd, Washington, D.C., December 10-12, 1973, Proceedings

Subjects considered are related to the remote passive sensing of atmosphere pollutants, the extension of laboratory measurement techniques for field use, instrument quality and measurement standardization, the remote active sensing of atmospheric pollutants, stationary source sensing, and air quality standards and measurement accuracy. Aspects of radiological, electromagnetic, and acoustic pollution monitoring are discussed together with new methods in particulate analysis, the measurement of meteorological variables that impact on atmospheric pollutants, and the impact of meteorological parameters on pollution analysis. The in-situ sensing of acoustic chemical and biological pollutants is reported along with global scale pollution monitoring and the remote sensing of water pollutants. Individual items are announced in this issue.

Source record↗

Intermediate term frequency measurements with the HP computing counter in the USNO clock time system

High precision frequency measurements with various integration times can be made with conventional counters by using variable gate times. The Hewlett-Packard (HP) computing counter allows such measurements over a wide range of frequencies and measurement times. This instrument can also convert period measurements into frequency by means of its arithmetic capabilities: The program library contains programs to facilitate frequency stability measurements in the most direct and convenient way. This method was used as the basis for all time scale computations, until requirements for highest resolution justified the development of an automatic data acquisition system. The phase measurements are now being made with the HP computing counter (with time interval plug-in unit) under program control from the HP System Programmer.

Winkler, G. M. R.↗

Survey of quantitative data on the solar energy and its spectra distribution

This paper presents a survey of available quantitative data on the total and spectral solar irradiance at ground level and outside the atmosphere. Measurements from research aircraft have resulted in the currently accepted NASA/ASTM standards of the solar constant and zero air mass solar spectral irradiance. The intrinsic variability of solar energy output and programs currently under way for more precise measurements from spacecraft are discussed. Instrumentation for solar measurements and their reference radiation scales are examined. Insolation data available from the records of weather stations are reviewed for their applicability to solar energy conversion. Two alternate methods of solarimetry are briefly discussed.

Thekaekara, M. P.↗

NASA-JSC ozone observations for validation of Nimbus 7-LIMS data

A series of balloon flights undertaken to validate data received from the limb infrared monitor of the stratorphere instrument aboard the Nimbus 7 satellite is discussed. Ozone data profiles, which included altitude, pressure, and mixing ratio, obtained during both ascent and descent of the balloons are reported. The measurement concept, instrumental uncertainties, and temporal variations observed for several time periods are discussed.

Robbins, D. E.↗

High resolution X-ray scattering measurements for Advanced X-ray Astrophysics Facility /AXAF/

The Advanced X-ray Astrophysics Facility (AXAF) is to be an orbiting X-ray observatory with high resolution imaging capabilities. Specific goals of 0.5 arcsecond resolution, and an encircled energy of 60% within a 1.0 arcsecond diameter circle at 2.5 keV have been established for AXAF. Imaging X-ray optics are primarily limited by scattering of the X-rays from the mirror surfaces. To ensure that the AXAF goals can be met, comprehensive X-ray scattering measurements are being conducted on a large number of flat samples. Sub-arcsecond resolution is achieved in these measurements through use of the MSFC 1000 ft X-ray calibration facility and a high spatial resolution X-ray detector. Flats of various materials, various coatings, and a range of rms surface roughness are being evaluated. Direct evaluation of surface microroughness is also provided by a variety of optical and non-optical means. This paper describes the scattering measurement program, the instrumentation used to obtain the measurements and preliminary results of measurements on several of the sample flats.

Zombeck, M. V.↗