Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Method Development for In Situ Microbiome Profiling of the Water Recovery System’s Wastewater Tank Onboard the International Space Station

A distinctive microbial community has inhabited the wastewater tank within the International Space Station Water Recovery System (WRS) for over 14 years and experienced the stressors associated with the microgravity environment. The WRS generates potable water for the crew from urine distillate, humidity condensate, Sabatier product water, and the occasional off-loading of ground-supplied water. The reservoir for these products, the wastewater tank, does not have a means of microbial control. While samples are occasionally collected for analysis, the time between sample collection and the return to Earth, as well as the lack of preservation, results in a skewed depiction of the microbiome. Routinely observed from these returned samples are high counts (105 – 106 colony forming units per mL) and two prevailing genera, Burkholderia and Ralstonia. The wastewater tank likely contains a more diverse microbiome, as a higher diversity of bacteria and fungus has been noted upstream and downstream of the tank. To characterize the microbial profile of the tank, analysis needs to occur at the time of sample collection. Toward this goal, a method for in situ analysis based on nanopore sequencing was developed. The filter-to-sequencer method evolved from previous work that has been validated onboard the ISS (BEST payload and the BioMole Crew Health Care Systems Facility). The method, including filtration, DNA extraction, purification, amplification, library preparation, and nanopore sequencing will be described. Additionally, data collected with this method from both ISS and terrestrial samples will be detailed. The consumables needed to support in situ analysis of the tank are set to the launch to the ISS in the spring of 2023. This investigation will allow for the first accurate characterization of the microbiome of the tank providing insight for crew health, planetary protection, and has the potential to enable engineering controls for future space station water systems.

Sarah Stahl-Rommel↗

Method Development for Multiplex, In-Situ, and Real-Time Detection of Herpesvirus Reactivation in Spaceflight Crews using Nanopore Sequencing

Reactivation of latent herpesviruses in crews onboard the International Space Station (ISS) is a well-established spaceflight-associated phenomenon and has been linked to overall immune stress. Beyond an indicator of an altered immune state, this stress-induced reactivation of viruses such as herpesvirus simplex virus 1 (HSV-1), Epstein-Barr virus (EBV), and Varicella-Zoster virus (VZV) may cause clinical symptoms in crew. There is currently no established protocol for in-flight monitoring, and samples are analyzed post-flight using ground-based assays. A real-time, in-flight method for herpesvirus detection followed by stress-mitigation strategies would be a significant advance. In this study, we developed a real-time assay for the multiplex detection of HSV-1, EBV, and VZV from saliva that could be implemented for in-situ monitoring of ISS crew. This method builds on previously validated spaceflight-compatible portable molecular protocols and platforms, such as the miniPCR thermal cycler and the MinION sequencer. Since a metagenomic approach is not currently permitted for crew samples (NASA policy), we employed multiplexing-ready primers directed toward targeted regions within the HSV-1, EBV, and VZV genomes. We also used primers for the human gene, Statherin (STATH), as an internal control. These primers were validated using spiked-in, positive control HSV-1, EBV, and VZV from virus-negative saliva extracted using the Zymo-Research Quick-DNA/RNA Viral MagBead Kit. The PCR Barcoding Kit was used to prepare DNA libraries that were then sequenced on the MK1C and analyzed against known reference genomes using minimap2. Following validation of this method with spiked saliva samples, suspected herpesvirus-positive clinical saliva samples were successfully tested. Prior to use onboard the ISS, this method will be deployed to an analog environment during overwintering at Palmer Station, Antarctica in 2023. This work represents the successful application of molecular technologies currently onboard the ISS for the real-time monitoring of latent herpesvirus reactivation from saliva samples. This assay, in combination with stress-reduction strategies, holds the potential to manage herpesvirus reactivation in ISS crew, thereby improving health outcomes and overall immunity.

Patrick M. Rydzak↗

Modeling and Simulation of the Angel Upper Limb Offload Device: Branching Into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E. Z. Klier↗

GC/MS Method Development for Separating Lunar Volatile Ice Simulant Headspace Gases

Various investigators propose the lunar surface contains widely distributed volatiles, especially water- like species, i.e. OH and H2O. Surface volatiles are theorized to exist as a hydrated regolith layer, concentrated in extremely cold polar permanently shadowed regions (PSR), and/or solar wind implantation reservoirs in lunar glasses. The proposed sources of lunar surface volatiles range from cometary impacts, solar wind, or a supply present during moon formation. Future Artemis missions aim to collect and return the samples containing volatiles collected near lunar polar craters or PSRs. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving returned sample integrity as much as possible. Pristine volatile-bearing samples are invaluable to the scientific community seeking to unravel the history of the solar system. Realistically, a sample will experience alteration during collection, transportation back to earth, and storage. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on high-fidelity volatile-containing regolith simulants, the foundation for the future of cold curation. This abstract outlines the separation, identification, and quantification of headspace gases over volatile ice feed stock material using gas chromatography/mass spectrometry (GC/MS). Preliminary objectives concentrated on sample handling, reproducibility, and understanding the elution characteristics for each analyte. Initial GC/MS method development experiments utilized diluted static headspace sample preparation. Diluted samples were used because sampling headspace gases directly from a vial containing liquid analyte resulted in overloading of the column and detector. Overloading is evident based on chromatogram peak shapes and instrument contamination, or carry over, between experiments. A mixture of three alcohols were used for a majority of the sample handling and reproducibility studies. Reproducibility was tested via multiple users, calibration curves, and check standards. Stock solutions of condensed lunar volatile analytes included methanol, ammonia in methanol, hydrogen sulfide in water, and an equal volume mixture of methanol, ethanol, and isopropanol. Current samples use room air as the headspace sample matrix, however future experiments will incorporate an inert purge gas, such as argon or nitrogen. Three mL of each analyte solution were capped in separate 20 mL crimp top GC vials. Dilutions were carried out by removing an aliquot of headspace gases with a calibrated 1 mL gastight syringe and immediately transferring to a 20 mL capped crimp top vial. The GC/MS is a Thermo Fisher Trace 1310/ISQ 7000 with a TriPlus RSH autosampler and split/splitless injector module. The experiments outlined in this abstract use the following hardware: a 2.5 mL gastight headspace syringe tool, 1 mm ID x 78.5 mm length ultra-inert straight injection liner, and a TG-BondQ 30 m × 0.32 mm × 10 μm column. Various parameters, such as hardware selection and the temperature, pressure, and split ratio set points, continue to evolve as the overall experiment is refined. Diluted headspace chromatograms were collected for the individual stock solutions. Retention times, peak shapes, and mass spectra were evaluated and added to the data processing method for each molecule of interest. Figure 1 shows the total ion chromatograms for the three major lunar volatile simulant stock solutions: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. Tailing peak shapes for ammonia (2.98 min rt) and water (4.06 min rt) indicate the molecules are not properly eluting from the selected column with the current separation method. Additionally, hydrogen sulfide and ammonia have overlapping peak windows, which could impact quantification. Ongoing experiments aim to address the peak shape and overlapping via the separation method and hardware selection. Sample preparation reproducibility experiments used stock solution containing equal volumes of a non- interactive mixture of methanol, ethanol, and isopropanol. Mass spectrum ion traces were used to identify and quantify all three alcohols. Peaks were automatically detected, identified, and integrated through the mass spectra detection and processing parameters. Calibration response curves and check standards were used to evaluate the validity of the sample preparation procedure. Figure 2 shows the methanol chromatogram peak area versus total headspace dilution volume transferred from the alcohol mixture vial. The calibration response curves and check standards validate sample preparation procedure. Continuing data analysis efforts are working towards correlating the peak area and instrument response factor to the headspace analyte concentration and condensed phase composition. Static headspace gas chromatography theory relies on Dalton’s law, Raoult’s law, Henry’s Law, and the Kolb and Ettre equation to associate peak area to the analyte composition in a non-ideal solution. Equation 1 is a simplified expression derived from the aforementioned theories. Future experiments involve liquid injections of the individual stock solutions, liquid and headspace analysis of various stock solution combinations, and the addition of regolith simulants to the mixtures. Temperature is another variable expected to affect reaction rates and will be explored.

Cecilia L. Amick↗

Microscopy Methods for Life Detection on Ocean Worlds

On Earth, light microscopy is commonly used in microbiology to identify organisms and observe their interactions with the environment; this makes it an attractive technique for in situ life detection methods on ocean worlds. As a standalone technique, brightfield microscopy, while able to provide important contextual information, has limited usefulness as a life detection technique because it is often challenging to differentiate between abiotic and biotic particles based solely on their size and shape, which may introduce risks of false positive or false negative interpretations. However, these risks can be reduced by combining brightfield microscopy with fluorescence microscopy to provide a method that correlate sample chemistry with sample morphology. In this work, we have used the Luminescence Imager for Exploration (LIfE), a brightfield and epifluorescence microscope with an integrated sample processing system (matured under the Concepts for Ocean worlds Life Detection Technology and Instrument Concepts of Europa Exploration programs) to develop methods that increase the fidelity of in situ microscopy life detection measurements through two main approaches. First, native fluorescence is excited in molecules that contain aromatic moieties such as proteins (using deep UV excitation), and energy carrying molecules and endogenous chromophores (using visible-light excitation), to correlate the location of these species with cell-like structural features (brightfield imaging). Second, fluorescent stains are used to selectively image cells and cell fragments by targeting proteins, lipids, and nucleic acids. We discuss the results of tests, obtained using ocean world analog samples, that have examined trades associated with implementing these methods autonomously in planetary missions, including the intrinsic properties of candidate fluorescence dyes and long-term storage and radiation stability.

Pavel E Z Klier↗

Modeling and Simulation of The Angel Upper Limb Offload Device: Branching into New Methods

BACKGROUND: The Active Response Gravity Offload System (ARGOS) provides an analog environment for extravehicular activity (EVA) testing and training. Discomfort has been observed during longer suited test sessions. While the subject’s core is offloaded during surface EVA evaluations, his/her arms experience full Earth gravity and can become overly fatigued, especially during suited tests which involve reaching and prolonged arm extensions. A device (ARGOS Negation of Gravitational Effects on the Limbs: ANGEL) to offload the weight of the arms and suit sleeves is being developed by JSC’s Flight Systems Branch of the Software, Robotics, and Simulation Division. Previously we have shared preliminary modeling of that device and kinematics based on motion capture data. Here we present an alternative approach to determine device kinematics by calculating ANGEL component angles with an OpenSim plugin. We compare calculated angles to inverse kinematics (IK) derived ones with the goal of validating the model. This new method can be further informative for device design and analytically testing different configurations to achieve desired reduced gravity conditions (e.g., lunar gravity (Lg) or Martian gravity (Mg)). We have compared calculated angles with IK-derived angles in tests with a shirt-sleeve subject positioned in a test stand with a Mark-III Hard Upper Torso (HUT) and Portable Life Support System (PLSS) mockup and arm weights to emulate the weight of the suit sleeve as well as a suited subject in ARGOS with a Mark-III suit. A variety of upper body tasks were completed in the former and full-body tasks in the latter. METHODS AND RESULTS: To model the offload device, we augment the OpenSim human model topology with the offload mechanism components and joints, using CAD models to represent the mechanism graphically. The joint angles of the device are calculated in the OpenSim plugin by modeling how the components configure themselves under the offloading spring tension given a particular IK-derived arm position. There are four ANGEL components with a total of 5 degrees of freedom (DOFs), each component has a single DOF except for the cuff which is modeled as 2 DOFs. The sickle/yaw bracket and cuff rotation angles are determined statically based on the assumptions that the sickle will track the attachment point of the cuff and that the cuff will rotate such that the attachment point is at its highest point. The cuff tilt, linker and V-bracket angles are then determined by optimizing their positions to approach a mechanical equilibrium. The calculated linker angle is compared to three different methods of determining the linker line-of-force kinematically (from V-bracket to center-cuff, cuff highest point or marker-derived position). Given the joint angles of the device, the spring force and resulting force on the arm is computed by the plugin and applied as an external load in inverse dynamics (ID) to enable study of overall shoulder joint torques as well as offload achieved. We verify the calculated joint angles by using the inverse kinematic data. The average difference in angles is the smallest for the V-bracket and linker, around 1 to 5 degrees for most trials. The resulting offload and shoulder torque are comparable between calculated and IK-derived angles. In summary, we have developed a method to calculate the joint angles of an exoskeleton-like upper limb offloading device currently in development. We have also developed a custom plugin which will be a valuable tool to optimize device configurations for a desired gravitational environment, probe the offload achieved for motions recorded outside of our test suite, and inform future design improvements.

L B Nilsson↗

Nanopore Sequencing-Based Microbial Air Profiling Method for Crewed Spacecraft

Microbial monitoring of the International Space Station (ISS) atmosphere is vital to maintaining the health of the spacecraft and crew. Key to NASA’s microbial risk assessment is the identity of contaminating microorganisms in the environment. Historically, this has been achieved through impaction-based air sampling followed by culture. Identification of the microorganisms present requires sample return to Earth and lab-based analyses. While this culture-based approach has served to provide alerts to anomalies and overall confidence in the controls in place, it is not suitable for exploration missions with no sample return. Recently, significant advancements in molecular-based microbial monitoring via nanopore sequencing have been implemented onboard the ISS. Building on this work, multiple commercially available air samplers, compatible with downstream molecular analysis, were evaluated for use in the spaceflight environment. Through this assessment, the Coriolis Compact (Bertin Technologies), which uses cyclonic technology to collect bioaerosols onto the surface of a sterile cone, was selected for a larger-scale comparison to the current culture-based monitoring method. Using the Coriolis Compact, 1000 L of air was collected from the breakroom of an office building and a fitness center. The buffer used to dissociate the microbial cells from the surface of the cone was split between the NASA Microbiology Laboratory’s standard culture and Sanger sequencing-based method and the culture-independent nanopore sequencing method. The bacteria identified through culture were present in the nanopore data, with Micrococcus, Staphylococcus, and Moraxella being the most common cultured isolates, which is expected based on the media and growth conditions. Not surprisingly, the nanopore data yielded much higher diversity and paralleled that of previous atmospheric microbiome studies of human-occupied built environments. As compared to the culture-based data where the breakroom and fitness center data sets cluster in proximity, the nanopore data depicts the contrast of these atmospheric microbiomes. Moreover, the nanopore data were sufficient to meet NASA’s risk assessment needs and noted the culturable isolates routinely observed. This nanopore-based atmospheric microbial profiling method will enable near real-time environmental monitoring of crewed spacecraft as future missions extend beyond low-Earth orbit.

Brandon Dunbar↗

NASA Kennedy Space Center Swamp Works: Innovation Methods for Advanced Research & Technology Development

Kennedy Space Center’s (KSC) Swamp Works, provides government and commercial space ventures with the technologies required for working and living on the surfaces of the Moon or other planets and bodies in our solar system. The Swamp Works team establishes agile, innovative and cost effective exploration mission solutions through leveraging of partnerships across NASA, industry and academia. Concepts start small and build up efficiently, with lean development processes and a hands on approach. Testing is performed in early stages to drive design improvements and progressively increase Technology Readiness Levels (TRL). Swamp Works provides concepts, architecture studies and trades, designs, data, technology development, technology demonstration hardware, flight hardware, testing, flight support and knowledge in support of the development of surface systems. This paper will summarize the state of the art in innovation methods, and it will compare the various other methods to how innovation is accomplished at the NASA KSC Swamp Works. Since 2013, Swamp Works has developed a wide variety of technologies, and has demonstrated viable methods for innovation while also collaborating with other government agencies, industry and academia to support space exploration. These methods focus on agile design, test, build iterations where each cycle of prototyping results in improved knowledge and designs. Failures are tole rated in the early stages of these iterations, since the overall development cycle is shorter more efficient and cost effective by retiring risk early in the cycle. Momentum is maintained and the development teams remain highly motivated by the high level of team work, technical excellence, engagement and creative freedom.

Robotic Mining↗

A New Method for the Accurate Calculation of Derivatives at Structured Multiblock Grid Singularities

The new Structured Mapping At Reduced dimension Topology elements (SMART) method for the accurate calculation of derivatives at multiblock structured grid block interfaces is presented. In the SMART method, a ’local’ curvilinear mapping is defined at each interface point, giving a consistent multidimensional definition of the derivatives. The resulting system of equations is overdetermined, and a least squares method is used to determine the value of the derivatives in the local coordinate system. In the special case of a nonsingular interface point, the SMART method automatically recovers the spatial differencing stencils used at the interior points in the neighboring grid blocks.

Computational Aeroacoustics↗

Advanced Statistical Methods in Spacecraft Flight Software Cost Estimation: Bayesian Regression and Nonlinear Principal Components Analysis to Support System Engineering in the Early Project Lifecycle

This paper provides an overview of the new features and model updates in the upcoming release of the NASA Analogy Software Cost Tool (ASCoT). ASCoT, hosted within the Online NASA Space Estimation Tools (ONSET) on the One NASA Cost Engineering (ONCE) Database, is a web-based tool that provides a suite of estimation tools to support early lifecycle NASA flight software cost analysis. In addition to the traditional parametric flight software costing method COCOMO II, ASCoT contains a Bayesian linear regression to predict total flight software development cost as a function of total spacecraft cost, as well as four analogic methods: k-Nearest Neighbors (kNN) and Clustering models to predict Effort (in work-months) and total source lines of code (SLOC). These methods are designed to work primarily with system-level inputs such as mission type (orbiter, lander, etc.), mission destination (Earth, Inner Planetary, etc.), and the number of instruments and deployables. Nonlinear principal components analysis (NLPCA) is performed to find the principal features of the data composed of both categorical and numerical variables and is necessary prior to defining our analogic methods. Sensitivity analyses and in- and out-of-sample model performance results are presented for the Bayesian CER and the analogic models.

Johnson, James K.↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

A Method for Obtaining Surface Flow Vectors and Its Implementation in Interferometric Skin Friction Measurement

A new method was developed to extract surface flow vectors from an oilflow visualization image that has oil streaklines. The method is analogous to the PIV processing where the image is divided into interrogation windows. A representative flow direction is obtained for each interrogation window using image processing with a line-detection algorithm. Repeating the process for the entire image, one can find the surface vector field. The Hough transformation, Radon transformation and Machine Learning were used as line-detection algorithms. The obtained vector field is then postprocessed to filter spurious vectors and to apply smoothing. The method was tested on 2D and 3D models with different flow complexities. The method was able to predict surface flow vectors for all cases tested. The predicted surface flow vectors were used in obtaining the surface skin friction. The successful implementation of the surface flow vectors enables interferometric skin friction measurements on surfaces beneath 3D complex flows. In addition, the surface flow vectors can be superimposed on the oilflow visualization images to better explain the surface flow topology.

Surface flow vectors↗

Modeling Methods for 3D Lightning Mapping from Space

Global lightning detection has advanced greatly over the past few decades both on ground and from orbit. Ground-based systems like the Lightning Mapping Array (LMA) excel at high-precision 3D reconstruction of local flashes, while spaceborne lightning sensors have much larger potential coverage but are limited by coarser resolution and often rely on data from other instruments to determine 3D flash locations. CubeSpark is a new mission concept focused on combining these two methods in the form of six small satellites in low-Earth orbit. CubeSpark will combine RF and bispectral optical measurements of lightning in order to map the 3D structure of both individual flashes and their parent thunderstorms at 1-2 km spatial resolution on a global scale, enabling a host of new atmospheric, climate, and space electricity studies. The goal of this study is to assess the feasibility and expected resolution of lightning mapping via indivudal VHF sources using different methods and detector combinations. Flashes were simulated beneath orbital configurations consisting of 1-6 satellites, taking into account the complicated interactions with Earth's ionosphere. In the multi-satellite (>5) approach, RF detectors on each satellite measure the arrival times of impulsive VHF sources to collectively pinpoint their locations in 3D and reconstruct flashes with higher resolution than has been achieved from space. The same can process can be performed with 3-4 satellites by constraining sources' horizontal locations with onboard optical imagers. A 1-2 station approach follows the established method of determining the height of an RF source using the arrival time difference between direct RF waves and their reflections off the Earth's surface. Here we present preliminary results of the expected accuracy of these methods to inform potential satellite missions like CubeSpark.

Lightning↗

Optimizing spectroheliogram deconvolution methods : MaGIXS - A case study

Over the past five years, new methods to reconstruct spectrally pure maps of the Sun from spectroheliogram data have emerged. In particular, with the rebirth of long-abandoned slitless imaging spectroscopy, one may obtain both spatial and spectral information over a large field of view simultaneously. Yet, depending on the size of the extended source combined with the extent of spectral dispersion, there will be locations in the focal plane where spectral lines from different spatial locations overlap and must be deconvolved. An unfolding method has been successfully developed and demonstrated on the recent rocket flight MaGIXS, which observed several strong emission lines (9 to 30$\AA$) from different portions of two active regions. In the work we are going to present, we conduct a systematic investigation of the parameters that controls and optimizes the inversion method to unfold overlappogram data. We also demonstrate a derived method of the inversion that does not require previous assumptions on the thermal and ionization equilibrium and abundance state of the plasma.

Spectroheliogram↗

Verification and Validation of Progressive Damage and Failure Analysis Methods for Intralaminar Failure Modes in Thermoplastic Composites

Current progressive damage and failure analysis (PDFA) methods were developed around thermoset material systems and their physical behavior. However, the applicability of these analysis methods has not been evaluated for use in modeling thermoplastic material systems. As part of the Hi-Rate Composite Aircraft Manufacturing (HiCAM) Project sponsored by NASA, intralaminar failure characterization was completed on a thermoplastic material system, AS4D/PEKK-FC, with off-axis tension (OAT) and off-axis compression (OAC) testing. The experiments were able to capture matrix non-linear shear behavior and the failure envelope of the material system. Two PDFA methods, LS-DYNA MAT299 and NASA’s CompDam-DGD, were then employed to simulate individual coupon behavior and simulation results were compared to published verification and validation guidelines from the CMH-17 crashworthiness working group. The results found that the two modeling methods provided suitable representation of material behavior of thermoplastics.

PDFA↗

Verification and Validation of Progressive Damage and Failure Analysis Methods for Intralaminar Failure Modes in Thermoplastic Composites

Current progressive damage and failure analysis (PDFA) methods were developed around thermoset material systems and their physical behavior. However, the applicability of these analysis methods has not been evaluated for use in modeling thermoplastic material systems. As part of the Hi-Rate Composite Aircraft Manufacturing (HiCAM) Project sponsored by NASA, intralaminar failure characterization was completed on a thermoplastic material system, AS4D/PEKK-FC, with off-axis tension (OAT) and off-axis compression (OAC) testing. The experiments were able to capture matrix non-linear shear behavior and the failure envelope of the material system. Two PDFA methods, LS-DYNA MAT299 and NASA’s CompDam-DGD, were then employed to simulate individual coupon behavior and simulation results were compared to published verification and validation guidelines from the CMH-17 crashworthiness working group. The results found that the two modeling methods provided suitable representation of material behavior of thermoplastics.

PDFA↗

New Cryogenic Method for Combining Lunar Regolith Simulant and Frozen Volatiles to Generate Icy Lunar Simulated Regolith

There is a requirement within the lunar science and exploration communities to develop lunar simulants containing volatiles that are solids at the cryogenic temperatures found in the permanently shadowed regions (PSRs), such as those found near the Lunar South Pole. Icy regolith simulants would be used for curation training, as well as for various research activities. One of the most critical aspects of developing a regolith simulant that is more physically and chemically like icy lunar regolith is minimizing any form of modification driven by elevated temperatures. Here we document our ongoing efforts to combine materials at ultralow temperatures, designed to minimize any chemical reactions or other physical changes during the production of the icy regolith. Our goal is to document how one can create an essentially “unreacted” icy regolith that can serve as an effective “time zero” start point from which advanced curation research will proceed. This is done using commercial off-the-shelf equipment as much as possible, along with creating a custom spray plate that can be adapted to a wide variety of methods, all for the planetary simulant community. This method creates crystals of various volatiles such as water, methanol, along with CO 2 ice and these components are combined with lunar regolith that is at -196°C temperature to avoid chemical reactions, and/or phase changes thus creating a more chemically relevant icy lunar regolith. The rules of chemistry stay the same regardless of location whether it’s in the lab, or directly on the lunar surface, and therefore we aim for creating a more authentic icy lunar simulant in the laboratory by operating at ultralow temperatures. It is also envisioned that this method will lead to advanced materials testing in the future. In addition, this method is directly applicable to prior missions such as LCROSS.

Cryogenic Lunar Simulant and Icy Volatile Producti↗