Epitaxial ferromagnetic Fe{sub 3}Si on GaAs(111)A with atomically smooth surface and interface

Single crystal ferromagnetic Fe{sub 3}Si(111) films were grown epitaxially on GaAs(111)A by molecular beam epitaxy. These hetero-structures possess extremely low surface roughness of 1.3 Å and interfacial roughness of 1.9 Å, measured by in-situ scanning tunneling microscope and X-ray reflectivity analyses, respectively, showing superior film quality, comparing to those attained on GaAs(001) in previous publications. The atomically smooth interface was revealed by the atomic-resolution Z (atomic number)-contrast scanning transmission electron microscopy (STEM) images using the correction of spherical aberration (Cs)-corrected electron probe. Excellent crystallinity and perfect lattice match were both confirmed by high resolution x-ray diffraction. Measurements of magnetic property for the Fe{sub 3}Si/GaAs(111) yielded a saturation moment of 990 emu/cm{sup 3} with a small coercive field ≤1 Oe at room temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of the Durability of PEM FC Membrane Electrode Assemblies in Automotive Applications through the Fundamental Understanding of Membrane and MEA Degradation Pathways

The Project focused on mitigation of degradation processes on membrane electrode assemblies. The approach was to develop a model to improve understanding of the mechanisms, and to use it to focus mitigation strategies. The detailed effects of various accelerated stress tests (ASTs) were evaluated to determine the best subset to use in model development. A combination of ASTs developed by the Fuel Cell Commercialization Conference of Japan and the Fuel Cell Tech Team were selected for use. The ASTs were compared by measuring effects on performance, running in-situ diagnostics, and performing microscopic analyses of the membrane electrode assemblies after the stress tests were complete. Nissan ran FCCJ AST protocols and performed in situ and ex-situ electrochemical testing. DuPont ran FCTT and USFCC AST protocols, performed scanning and transmission electron microscopy and ran in-situ electrochemical tests. Other ex-situ testing was performed by IIT, along with much of the data analysis and model development. These tests were then modified to generate time-dependent data of the degradation mechanisms. Three different catalyst types and four membrane variants were then used to generate data for a theoretically-based degradation model. An important part of the approach was to use commercially available materials in the electrodes and membranes made in scalable semiworks processes rather than lab-based materials. This constraint ensured all materials would be practicable for full-scale testing. The initial model for the electrode layer was tested for internal consistency and agreement with the data. A Java-based computer application was developed to analyze the time-dependent AST data using polarization curves with four different cathode gas feeds and generate model parameters. Data showed very good reproducibility and good consistency as cathode catalyst loadings were varied. At the point of termination of the project, a basic electrode model was in hand with several areas identified for improvement. Time dependence and the membrane portion of the model were not addressed due to cancellation of Phase 2 of the Project.

08 HYDROGEN↗

Ion microprobe, electron microprobe and cathodoluminescence data for Allende inclusions with emphasis on plagioclase chemistry

Three Type B inclusions from the Allende meteorite have been analyzed. A grain-to-grain characterization of mineral chemistry and isotopic content was made possible by the use of a range of techniques, including luminescence and scanning electron microscopy and electron and ion microprobe analysis. Cathodoluminescence was used in fine-grained, optically opaque regions to distinguish between sub-micrometer phases, such as garnet and Si-rich material, subsequently identified by electron probe and scanning electron microscope analyses. Four types of luminescence patterns, due to twinning, primary sector zoning, alteration of boundaries and fractures, and shock effects, were identified in Allende plagioclase. Luminescence color exhibited a strong correlation with Mg content and provided a guide for an electron probe quantitative map of Mg and Na distributions. Ion microprobe studies of individual grains revealed large excesses of Mg-26.

Hutcheon, I. D.↗

Materials and Manufacturing Challenges for Compact Heat Exchangers of Supercritical CO2 Power Cycles

The supercritical CO2 (sCO2) power cycles rely heavily on heat recuperation to increase efficiency. Compact heat exchangers are proposed to reduce equipment size and enhance heat transfer between heat source and sCO2. Microchannel architectures in these heat exchangers are typically formed by a lamination process wherein channels are formed in layers of sheet material, which are then stacked and joined together using diffusion bonding, brazing, or transient-liquid-phase bonding (TLPB). TLPB of Ni-based superalloy (Alloy 230) sheets into stacks was investigated. Electron microscopy identified solidification shrinkage porosity on the bond line as the most common defect in the TLP bonded stacks. Tensile yield strengths of 76-86 % of the base alloy strength were obtained on bonded stacks. Scanning electron microscopy on the fracture surfaces indicated ductile failure mode in the bonded zone. Environmental stability of joined regions in Alloy 230 stacks was investigated by exposing to CO2 at 700°C for 1500 hours. Mass change and post-exposure microscopic analysis showed a corrosion behavior similar to the base material.

14 SOLAR ENERGY↗

LET Spectrum Measurements In CR-39 PNTD With AFM

Energetic protons, neutrons, and heavy ions undergoing collisions with target nuclei of varying Z can produce residual heavy recoil fragments via intra-nuclear cascade/evaporation reactions. The particles produced in these non-elastic collisions generally have such extremely short range ({approx}<10 {mu}m) that they cannot be directly observed by conventional detection methods including CR-39 plastic nuclear track detector (PNTD) that has been chemically etched for analysis by standard visible light microscopy. However, high-LET recoil fragments having range on the order of several cell diameters can be produced in tissue during radiotherapy using proton and carbon beams. We have developed a method to analyze short-range, high-LET tracks in CR-39 plastic nuclear track detector (PNTD) using short duration chemical etching ({approx}<1 {mu}m) following by automated atomic force microscope (AFM) scanning. The post-scan data processing used in this work was based on semi-automated matrix analysis opposed to traditional grey-scale image analysis. This method takes advantage of the 3-D data obtained via AFM to achieve robust discrimination of nuclear tracks from other features inherently present in the post-etch detector surface. Through automation of AFM scanning, sufficient AFM scan frames were obtained to attain an LET spectrum spanning the LET range from 200-1500 keV/{mu}m. In addition to our experiments, simulations were carried out with the Monte Carlo transport code, FLUKA. To demonstrate this method, CR-39 PNTD was exposed to the proton therapy beam at Loma Linda University Medical Center (LLUMC) at 60 and 230 MeV. Additionally, detectors were exposed to 1 GeV protons at the NASA Space Radiation Laboratory (NSRL) at Brookhaven National Laboratory (BNL). For these exposures CR-39 PNTD, Al and Cu target foils were used between detector layers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reducing adhesion energy of micro-relay electrodes by ion beam synthesized oxide nanolayers

Reduction in the adhesion energy of contacting metal electrode surfaces in nano-electro-mechanical switches is crucial for operation with low hysteresis voltage. We demonstrate that by forming thin layers of metal-oxides on metals such as Ru and W, the adhesion energy can be reduced by up to a factor of ten. We employ a low-energy ion-beam synthesis technique and subsequent thermal annealing to form very thin layers (~2 nm) of metal-oxides (such as RuO 2 and WO x ) on Ru and W metal surfaces and quantify the adhesion energy using an atomic force microscope with microspherical tips.

36 MATERIALS SCIENCE↗

Exploring the Relationship of Microstructure and Conductivity in Metal Halide Perovskites via Active Learning-Driven Automated Scanning Probe Microscopy

Electronic transport and hysteresis in metal halide perovskites (MHPs) are key to the applications in photovoltaics, light emitting devices, and light and chemical sensors. These phenomena are strongly affected by the materials microstructure including grain boundaries, ferroic domain walls, and secondary phase inclusions. Here, we demonstrate an active machine learning framework for “driving” an automated scanning probe microscope (SPM) to discover the microstructures responsible for specific aspects of transport behavior in MHPs. In our setup, the microscope can discover the microstructural elements that maximize the onset of conduction, hysteresis, or any other characteristic that can be derived from a set of current–voltage spectra. Furthermore, this approach opens new opportunities for exploring the origins of materials functionality in complex materials by SPM and can be integrated with other characterization techniques either before (prior knowledge) or after (identification of locations of interest for detail studies) functional probing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Space Microscopic Electrical Imaging of n+-p Junction Beneath Front-Side Ag Contact of Multicrystalline Si Solar Cells

We investigated the quality of the n+-p diffused junction beneath the front-side Ag contact of multicrystalline Si solar cells by characterizing the uniformities of electrostatic potential and doping concentration across the junction using the atomic force microscopy-based electrical imaging techniques of scanning Kelvin probe force microscopy and scanning capacitance microscopy. We found that Ag screen-printing metallization fired at the over-fire temperature significantly degrades the junction uniformity beneath the Ag contact grid, whereas metallization at the optimal- and under-fire temperatures does not cause degradation. Ag crystallites with widely distributed sizes were found at the Ag-grid/emitter-Si interface of the over-fired cell, which is associated with the junction damage beneath the Ag grid. Large crystallites protrude into Si deeper than the junction depth. However, the junction was not broken down; instead, it was reformed on the entire front of the crystallite/Si interface. We propose a mechanism of junction-quality degradation, based on emitter Si melting at the temperature around the Ag-Si eutectic point during firing, and subsequent re-crystallization with incorporation of Ag and other impurities and with formation of crystallographic defects during quenching. The effect of this junction damage on solar cell performance is discussed.

14 SOLAR ENERGY↗

Photo-exfoliation of MoS 2 quantum dots from nanosheets: an in-situ transmission electron microscopy study

Fabrication of transition metal dichalcogenide (TMD) quantum dots (QDs) is complex and requires submerging of powders in binary solvents and the constant tuning of wavelength and pulsed frequency of light to achieve a desired reaction. Here,iInstead of liquid state photoexfoliation, we utilize infrared laser irradiation of free-standing MoS 2 flakes in transmission electron microscope (TEM) to achieve solid-state multi-level photoexfoliation of QDs. By investigating the steps involved in photochemical reaction between the surface of MoS 2 and the laser beam, we gain insight into each step of the photoexfoliation mechanism and observe high yield production of QDs, led by an inhomogeneous crystalline size distribution. Additionally, by using a laser with a lower energy than the indirect optical transition of bulk MoS 2 , we conclude that the underlying phenomena behind the photoexfoliation is from multi-photon absorption achieved at high optical outputs from the laser source. These findings provide an environmentally friendly synthesis method to fabricate QDs for potential applications in biomedicine, optoelectronics, and fluorescence sensing.

36 MATERIALS SCIENCE↗

In Situ Transmission Electron Microscopy of High-Temperature Inconel-625 Corrosion by Molten Chloride Salts

This paper describes an approach to monitor high temperature molten chloride (MgCl 2 -NaCl-KCl) salt corrosion of Inconel-625 alloy in real time at high spatial resolution. The approach is based on a micro-environmental-cell assembly integrated into a transmission-electron-microscope goniometer to examine in situ the salt-alloy interface during corrosion, employing real time electron diffraction and imaging. It establishes procedures to minimize incorporation of H 2 O or O 2 from atmosphere in the chloride salts during sample fabrication and corrosion, which is critical to understanding the fundamental corrosion mechanisms. A clustering algorithm and a 2D Gaussian fit function are used to determine diffraction spot intensities in in situ diffraction patterns, to quantify alloy corrosion. This facilitates quantitative observation of the evolution of individual grains, in contrast to conventional macroscopic corrosion rate quantification. The isothermal corrosion rate of Inconel-625 in an anhydrous, unoxidized salt-stack is 220 ± 30 μm year -1 at 700 °C and 350 ± 20 μm year -1 at 800 °C. However, the corrosion rate at 700 °C increases five-fold to 1000 ± 170 μm year -1 when the salt stack is air-exposed, indicating the dominant effects of hydrated or oxidized impurities on corrosion acceleration. Furthermore, real time imaging of the microstructure evolution suggests that corrosion is initiated at grain boundaries.

14 SOLAR ENERGY↗

Nondestructive monitoring damage in composites using scanning laser acoustic microscopy

Several Nicalon fiber reinforced LAS (lithium alumino-silicate) glass matrix composites were tested to study the relation between the residual strength and the different amounts of damage. The samples were fatigued by four-point cyclic loading at a 5 Hz rate at 500 C for a different number of cycles. 10 MHz scanning laser acoustic microscope (SLAM) images were taken to monitor damage on the samples. Our SLAM results indicate that there were defects already existing throughout the sample before fatigue, and the resultant damage pattern from fatigue could be related to the initial defect distribution in the sample. Finally, the fatigued samples were fractured and the residual strength data could not be explained by the cyclic fatigue alone. Rather, the damage patterns evident in the SLAM images were needed to explain the scatter in the data. The results show that SLAM is useful in nondestructively monitoring damage and estimating residual strength of fatigued ceramic composites.

Wey, A. C.↗

Microscopic analysis of irradiated AGR-1 coated particle fuel compacts

The AGR-1 experiment involved irradiation of 72 TRISO-coated particle fuel compacts to a peak burnup of 19.5% FIMA with no in-pile failures observed out of 3×105 total particles. Irradiated AGR-1 fuel compacts have been cross-sectioned and analyzed with optical microscopy to characterize kernel, buffer, and coating behavior. Five compacts have been examined so far, spanning a range of irradiation conditions (burnup, fast fluence, and irradiation temperature) and including all four TRISO coating variations irradiated in the AGR-1 experiment. The cylindrical specimens were sectioned both transversely and longitudinally, then polished to expose between approximately 40-80 individual particles on each mount. The analysis focused primarily on kernel swelling and porosity, buffer densification and fracturing, buffer-IPyC debonding, and fractures in the IPyC and SiC layers. Characteristic morphologies have been identified, over 800 particles have been classified, and spatial distributions of particle types have been mapped. No significant spatial patterns were discovered in these cross sections. However, some trends were found between morphological types and certain behavioral aspects. Buffer fractures were found in approximately 23% of the particles, and these fractures often resulted in unconstrained kernel swelling into the open cavities. Fractured buffers and buffers that stayed bonded to IPyC layers appear related to larger pore size in kernels. Buffer-IPyC interface integrity evidently factored into initiation of rare IPyC fractures. Fractures through part of the SiC layer were found in only three particles, all in conjunction with IPyC-SiC debonding. Compiled results suggest that the deliberate coating fabrication variations influenced the frequencies of IPyC fractures, IPyC-SiC debonds, and SiC fractures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observing gas-catalyst dynamics at atomic resolution and single-atom sensitivity

Transmission electron microscopy (TEM) has become an indispensable technique for studying heterogeneous catalysts. Specifically, advancements of aberration-corrected electron optics and data acquisition schemes have made TEM capable of delivering images of catalysts with sub-Ångström resolution and single-atom sensitivity. Parallel developments of differentially pumped electron microscopes and of gas cells enable in situ observations of catalysts during the exposure to reactive gas environments at pressures of up to atmospheric levels and temperatures of up to several hundred centigrade. Here, we outline how to take advantage of the emerging state-of-the-art instrumentation and methodologies to study surface structures and dynamics to improve the understanding of structure-sensitive catalytic functionality. The idea of using low electron dose-rates in TEM in conjunction with in-line holography and aberration-correction at low voltage (80kV) is introduced to allow maintaining atomic resolution and sensitivity during in situ observations of catalysts. Benefits are demonstrated by exit wave reconstructions of TEM images of a nanocrystalline Co 3 O 4 catalyst material acquired in situ during their exposure to either a reducing or oxidizing gas environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Electron Spectro-Microscopy (ESM) Beamline at NSLS-II

Photoelectron spectroscopy is a primary tool for the study of the electronic structure of materials and the chemical composition of surfaces. High-resolution angle-resolved photoemission spectroscopy (ARPES) has the unique ability to map the energy bands in momentum space. Furthermore, going beyond the single particle picture, the self-energy corrections caused by correlations in solids can be extracted from the analysis of the emission line shape. The current level of refinement, in terms of energy and angular resolution (ΔE < 1 meV, Δθ < 0.1°), makes the technique sensitive to the lowest energy excitations and the dynamics of electrons, which in turn virtually determine all the macroscopic properties of any system and govern the chemical, electrical, magnetic, and physical processes. Similarly important, X-ray photoelectron microscopy (XPEEM), combined with the low-energy electron microscopy (LEEM), is indispensable in probing the complexity of chemical, structural, electronic and magnetic properties of surfaces and shallow interfaces, with the spatial resolution of few tens of nanometer (nm). The Electron-Spectro-Microscopy beamline (ESM) has been recently commissioned at NSLS-II and is now in operation. The primary spectroscopic technique is photoemission, performed over a wide energy range with control of light polarization and in a variety of flux/resolution conditions. The beamline has two experimental end stations that allow to perform ARPES and XPEEM/LEEM, separately. The ARPES end station focuses on high energy-resolution work, with spot-size of a few microns. The XPEEM/LEEM end station is a full-field microscope (XPEEM) operating either with the synchrotron generated X-rays (XPEEM), or with an internal electron gun (LEEM). Spatial resolution is crucial in studies of newly synthesized complex materials since they are often initially available only as small specimens (typically micron size). Furthermore, chemical inhomogeneities on surfaces are often an integral part of surface chemical processes. Finally, the ESM beamline with X-ray spots of few microns is optimized to study the electronic structure of novel materials with microscopy capabilities.

47 OTHER INSTRUMENTATION↗

Unraveling the Dissolution-Mediated Reaction Mechanism of α-MnO 2 Cathodes for Aqueous Zn-Ion Batteries

Aqueous Zn/α-MnO 2 batteries have attracted immense interest owing to their high energy density, low cost, and safety, making them desirable for future large-scale energy application. Despite these merits, the comprehensive understanding of their reaction mechanism has been elusive due to the limitations of standard bulk characterization. Here, via transmission electron microscopy, the dissolution-mediated reaction mechanism of a Zn/α-MnO 2 system is discovered and explored in full scope to involve reversible formation of Zn 4 SO 4 (OH) 6 · x H 2 O and “birnessite-like” Zn-MnO x phase upon cycling. Overall, α-MnO 2 acts primarily as a source for cell activation through dissolution and thus is not directly involved in the Zn redox chemistry. Overall, this microscopic study offers a unique knowledge on the unconventional reaction chemistry of Zn/α-MnO 2 batteries.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tunable, Ultrafast Fiber-Laser between 1.15 μm and 1.35 μm for Harmonic Generation Microscopy in Human Skin

We demonstrate a fiber-optic ultrafast tunable source for harmonic generation microscopy (HGM) in human skin. The source is based on a 31-MHz Er-fiber laser followed by self-phase modulation enabled spectral selection (SESS). The resulting pulses are tunable between 1.15 and 1.35 μm with up to >10-nJ pulse energy and ~100-fs pulse duration. Here we employ this source to drive a scanning microscope for HGM imaging of ex vivo human skin. A systematic investigation on imaging depth versus excitation wavelength reveals that excitation wavelengths in the 1.15-1.25 μm range exhibit low optical attenuation within the tissue and allows larger imaging depth for HGM in human skin. HGM driven by fiber-based SESS sources constitutes an enabling tool for noninvasive virtual skin biopsy in clinical applications.

60 APPLIED LIFE SCIENCES↗

Electron-irradiation-induced Cr segregation in Fe-Cr model alloy pre-implanted with hydrogen ions

Highlights: • Streaks appeared in the diffraction patterns of hydrogen-implanted Fe-Cr alloy after electron irradiation in an HVEM. • A kind of needle-like Cr precipitates give rise to the streaks. • The streaks are explained reasonably by shape effect of precipitates. - Abstract: Reduced activation ferritic/martensitic (RAFM) steels are widely accepted as the candidate structural materials for fusion reactors. To gain knowledge about Cr behaviour of these steels in such environments, Fe-Cr binary alloys have to be investigated. In this study, Fe-10 at.% Cr ferritic model alloy pre-implanted with hydrogen ions was electron-irradiated in a high voltage electron microscope (HVEM) at the temperature ranging from 300 °C to 600 °C. Streaks were observed in the diffraction patterns in the model alloy after electron irradiation at 450–550 °C and explained reasonably by shape effect. The analysis of transmission electron microscopy (TEM) reveals that the observed streaks are induced by a kind of needle-like precipitates with the directions along <100>. The dependence of the length and density of the precipitates on the temperature were studied. In addition, contrast experiments were conducted with pure Fe and Fe-10 at.% Cr alloy with and without hydrogen ion implantation, respectively. After electron irradiation, no streak was observed in the hydrogen-implanted pure Fe and Fe-10 at.% Cr alloy without the hydrogen implantation. Therefore, it is assumed that the needle-like precipitates could be the complex of Cr and H, which segregate and precipitate along <100> direction.

36 MATERIALS SCIENCE↗