Beam transport and monitoring for laser plasma accelerators

The controlled transport and imaging of relativistic electron beams from laser plasma accelerators (LPAs) are critical for their diagnostics and applications. Here we present the design and progress in the implementation of the transport and monitoring system for an undulator based electron beam diagnostic. Miniature permanent-magnet quadrupoles (PMQs) are employed to realize controlled transport of the LPA electron beams, and cavity based electron beam position monitors for non-invasive beam position detection. Also presented is PMQ calibration by using LPA electron beams with broadband energy spectrum. The results show promising performance for both transporting and monitoring. With the proper transport system, XUV-photon spectra from THUNDER will provide the momentum distribution of the electron beam with the resolution above what can be achieved by the magnetic spectrometer currently used in the LOASIS facility.

43 PARTICLE ACCELERATORS↗

Development of a novel ultrasonic temperature probe for long-term monitoring of dry cask storage systems

With the recent cancellation of the Yucca Mountain repository and the limited availability of wet storage utilities for spent nuclear fuel (SNF), more attention has been directed toward dry cask storage systems (DCSSs) for long-term storage of SNF. Consequently, more stringent guidelines have been issued for the aging management of dry storage facilities that necessitate monitoring of the conditions of DCSSs. Continuous health monitoring of DCSSs based on temperature variations is one viable method for assessing the integrity of the system. In the present work, a novel ultrasonic temperature probe (UTP) is being tested for long-term online temperature monitoring of DCSSs. Its performance was evaluated and compared with type N thermocouple (NTC) and resistance temperature detector (RTD) using a small-scale dry storage canister mockup. Our preliminary results demonstrate that the UTP system developed at Argonne is able to achieve better than 0.8 Degree-Sign C accuracy, tested at temperatures of up to 400 Degree-Sign C. The temperature resolution is limited only by the sampling rate of the current system. The flexibility of the probe allows conforming to complex geometries thus making the sensor particularly suited to measurement scenarios where access is limited.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The relevance of particle flux monitors in accelerator-based activation analysis

One of the most critical parameters in activation analysis is the flux density of the activating radiation, its spatial distribution in particular. The validity of the basic equation for calculating the activity induced to the exposed item depends upon the fulfilment of several conditions, the most relevant of them being equal doses of incident activating radiation received by the unknown sample, the calibration material and the reference material, respectively. This requirement is most problematic if accelerator-produced radiation is used for activation. Whilst nuclear research reactors usually are equipped with exposure positions that provide fairly homogenous activation fields for thermal neutron activation analysis accelerator-generated particle beams (neutrons, photons, charged particles) usually exhibit axial and, in particular, sharp radial flux gradients. Different experimental procedures have been developed to fulfil the condition mentioned above. In this paper, three variants of the application of flux monitors in photon activation analysis are discussed (external monitor, additive and inherent internal monitor). Experiments have indicated that the latter technique yields highest quality of the analytical results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electron line shape and transmission function of the KATRIN monitor spectrometer

Knowledge of the neutrino mass is of particular interest in modern neutrino physics. Besides the neutrinoless double beta decay and cosmological observation information about the neutrino mass is obtained from single beta decay by observing the shape of the electron spectrum near the endpoint. The KATRIN β decay experiment aims to push the limit on the effective electron antineutrino mass down to 0.2 eV/c{sup 2}. To reach this sensitivity several systematic effects have to be under control. One of them is the fluctuations of the absolute energy scale, which therefore has to be continuously monitored at very high precision. This paper shortly describes KATRIN, the technique for continuous monitoring of the absolute energy scale and recent improvements in analysis of the monitoring data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Invited Article: Radon and thoron intercomparison experiments for integrated monitors at NIRS, Japan

Inhalation of radon ({sup 222}Rn) and its short-lived decay products and of products of the thoron ({sup 220}Rn) series accounts for more than half of the effective dose from natural radiation sources. At this time, many countries have begun large-scale radon and thoron surveys and many different measurement methods and instruments are used in these studies. Consequently, it is necessary to improve and standardize technical methods of measurements and to verify quality assurance by intercomparisons between laboratories. Four international intercomparisons for passive integrating radon and thoron monitors were conducted at the NIRS (National Institute of Radiological Sciences, Japan). Radon exercises were carried out in the 24.4 m{sup 3} inner volume walk-in radon chamber that has systems to control radon concentration, temperature, and humidity. Moreover, the NIRS thoron chamber with a 150 dm{sup 3} inner volume was utilized to provide three thoron intercomparisons. At present, the NIRS is the only laboratory world-wide that has carried out periodic thoron intercomparison of passive monitors. Fifty laboratories from 26 countries participated in the radon intercomparison, using six types of detectors (charcoal, CR-39, LR 115, polycarbonate film, electret plate, and silicon photodiode). Eighteen laboratories from 12 countries participated in the thoron intercomparisons, using two etch-track types (CR-39 and polycarbonate) detectors. The tests were made under one to three different exposures to radon and thoron. The data presented in this paper indicated that the performance quality of laboratories for radon measurement has been gradually increasing. Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods. The present paper provides a summary of all radon and thoron international intercomparisons done at NIRS from 2007 to date and it describes the present status on radon and thoron passive, one-time cycle monitors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations

Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of resistivity monitoring to evaluate cement grouting effect in earth filled dam

In this paper, we applied electrical resistivity monitoring method to evaluate the cement grouting effect. There are a lot of ways to evaluate cement grouting effect. In order to do this evaluation in a great safety, high efficiency, and lower cost, resistivity monitoring is found to be the most appropriate technique. In this paper we have selected a dam site from Korea to acquire resistivity monitoring data and compare the results of inversion to estimate the cement grouting effect.

36 MATERIALS SCIENCE↗

Thermographic process monitoring in powderbed based additive manufacturing

Selective Laser Melting is utilized to build metallic parts directly from CAD-Data by solidification of thin powder layers through application of a fast scanning laser beam. In this study layerwise monitoring of the temperature distribution is used to gather information about the process stability and the resulting part quality. The heat distribution varies with different kinds of parameters including scan vector length, laser power, layer thickness and inter-part distance in the job layout which in turn influence the resulting part quality. By integration of an off-axis mounted uncooled thermal detector the solidification as well as the layer deposition are monitored and evaluated. Errors in the generation of new powder layers usually result in a locally varying layer thickness that may cause poor part quality. For effect quantification, the locally applied layer thickness is determined by evaluating the heat-up of the newly deposited powder. During the solidification process space and time-resolved data is used to characterize the zone of elevated temperatures and to derive locally varying heat dissipation properties. Potential quality indicators are evaluated and correlated to the resulting part quality: Thermal diffusivity is derived from a simplified heat dissipation model and evaluated for every pixel and cool-down phase of a layer. This allows the quantification of expected material homogeneity properties. Maximum temperature and time above certain temperatures are measured in order to detect hot spots or delamination issues that may cause a process breakdown. Furthermore, a method for quantification of sputter activity is presented. Since high sputter activity indicates unstable melt dynamics this can be used to identify parameter drifts, improper atmospheric conditions or material binding errors. The resulting surface structure after solidification complicates temperature determination on the one hand but enables the detection of potential surface defects on the other hand. These issues and proper key figures for thermographic monitoring of the Selective Laser Melting process are discussed in the paper. Even though microbolometric temperature measurement is limited to repetition rates in the Hz-regime and sub megapixel resolution, current results show the feasibility of process surveillance by thermography for a limited section of the building platform in a commercial system.

42 ENGINEERING↗

A method for the monitoring of metal recrystallization based on the in-situ measurement of the elastic energy release using neutron diffraction

A method is proposed for the monitoring of metal recrystallization using neutron diffraction that is based on the measurement of stored energy. Experiments were performed using deformed metal specimens heated in-situ while mounted at the sample position of the High Resolution Powder Diffractometer, HRPD (ISIS Facility), UK. Monitoring the breadth of the resulting Bragg lines during heating not only allows the time-dependence (or temperature-dependence) of the stored energy to be determined but also the recrystallized fraction. The analysis method presented here was developed using pure nickel (Ni270) specimens with different deformation levels from 0.29 to 0.94. In situ temperature ramping as well as isothermal annealing was undertaken. The method developed in this work allows accurate and quantitative monitoring of the recrystallization process. The results from neutron diffraction are satisfactorily compared to data obtained from calorimetry and hardness measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New approach to information fusion for Lipschitz classifiers ensembles: Application in multi-channel C-OTDR-monitoring systems

This paper presents new results concerning selection of an optimal information fusion formula for an ensemble of Lipschitz classifiers. The goal of information fusion is to create an integral classificatory which could provide better generalization ability of the ensemble while achieving a practically acceptable level of effectiveness. The problem of information fusion is very relevant for data processing in multi-channel C-OTDR-monitoring systems. In this case we have to effectively classify targeted events which appear in the vicinity of the monitored object. Solution of this problem is based on usage of an ensemble of Lipschitz classifiers each of which corresponds to a respective channel. We suggest a brand new method for information fusion in case of ensemble of Lipschitz classifiers. This method is called “The Weighing of Inversely as Lipschitz Constants” (WILC). Results of WILC-method practical usage in multichannel C-OTDR monitoring systems are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complementary bimodal approach to monitoring of photodynamic therapy with targeted nanoconstructs: numerical simulations

We propose a new approach to monitoring photodynamic therapy (PDT) of glioblastoma with the use of targeted nanoconstructs containing a photosensitiser (PS) [benzoporphyrin derivative (BPD)] and IRDye800 dye, antibodies for efficient accumulation of the drug in a tumour, and a chemotherapeutic agent for combined effect on tumour cells. Application of IRDye800 is determined by the shift of its absorption and fluorescence spectra to the near-IR range with respect to BPD that ensures a higher imaging depth. Monitoring of PDT is based on the simultaneous fluorescence and optoacoustic (OA) imaging. Fluorescence imaging provides visualisation of fluorescence agents with high molecular sensitivity and monitoring of the effectiveness of PDT by PS photobleaching. OA allows one to examine the vascular pattern of the tumour environment, as well as assess the depth of the tumour. IRDye800 is a better contrast agent in comparison to BPD due to red-shifted spectral characteristics and a higher fluorescence quantum yield. Monte Carlo simulations combined for OA simulations with K-wave modelling allowed the feasibility of the complementary approach to be studied and demonstrated that this combination allows one to localise a tumour with a size of 2 mm at depths from 100 μm to 2 mm. (paper)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lidar-based remote infrared gas sensor for monitoring anthropogenic pollution: a proof of concept

We propose using wavelength-modulation laser absorption spectroscopy in combination with quadrature detection of scattered light for remote industrial pollution monitoring in the atmosphere with a compact lidar-based gas sensor, which can be mounted on board an unmanned aerial vehicle. The instrument can be used for detecting leaks in product pipe lines; monitoring toxic gases near landfill sites, waste incineration plants, and other hazardous man-made facilities; analysing the gas atmosphere in industrial buildings and structures; and monitoring engineering processes at a sensitivity level of tens of ppm m in gas concentration measurements at characteristic distances of tens of metres. (laser applications and other issues in quantum electronics)

42 ENGINEERING↗

Autoregressive distributed lag-based dynamic uniformity modeling and monitoring approaches for superconductor manufacturing

High-temperature superconductors (HTS), known for their high efficiency and low energy loss, have found profound applications across various fields, driving the demand for long, uniformly performing tapes. However, ensuring uniform performance over extended lengths of HTS tapes, often characterized by the consistency of critical current, remains challenging due to fluctuations in growth conditions during manufacturing. Here, to elucidate the mechanisms underlying variations in tape uniformity and enable real-time monitoring of associated parameters, we propose an Autoregressive Distributed Lag (ADL)-based Dynamic Uniformity Modeling and Monitoring (ADUM2) approach. This method integrates uniformity measurement, the identification of critical process parameters and real-time monitoring within the manufacturing process. The ADUM2 approach is applied to the advanced metal organic chemical vapor deposition (A-MOCVD) process, a pilot-scale method for superconductor manufacturing. Our model demonstrates superior performance compared to benchmark methods, accounting for over 80% of the total variance in the data and identifying 13 key process parameters influencing the uniformity of HTS tapes. This study offers significant insights into the high-temperature superconductor manufacturing process and holds the potential to facilitate the production of cost-effective, uniformly performing long superconducting tapes in the future.

autoregressive distributed lag analysis↗

An integrated manifold learning approach for high-dimensional data feature extractions and its applications to online process monitoring of additive manufacturing

As an effective dimension reduction and feature extraction technique, manifold learning has been successfully applied to high-dimensional data analysis. With the rapid development of sensor technology, a large amount of high-dimensional data such as image streams can be easily available. Thus, a promising application of manifold learning is in the field of sensor signal analysis, particular for the applications of online process monitoring and control using high-dimensional data. The objective of this study is to develop a manifold learning-based feature extraction method for process monitoring of Additive Manufacturing (AM) using online sensor data. Due to the non-parametric nature of most existing manifold learning methods, their performance in terms of computational efficiency, as well as noise resistance has yet to be improved. To address this issue, this study proposes an integrated manifold learning approach termed multi-kernel metric learning embedded isometric feature mapping (MKML-ISOMAP) for dimension reduction and feature extraction of online high-dimensional sensor data such as images. Based on the extracted features with the utilization of supervised classification and regression methods, an online process monitoring methodology for AM is implemented to identify the actual process quality status. Finally, in the numerical simulation and real-world case studies, the proposed method demonstrates excellent performance in both prediction accuracy and computational efficiency.

36 MATERIALS SCIENCE↗

A REMARKABLE LONG-TERM LIGHT CURVE AND DEEP, LOW-STATE SPECTROSCOPY: SWIFT AND XMM-NEWTON MONITORING OF THE NLS1 GALAXY Mkn 335

The narrow-line Seyfert 1 galaxy (NLS1) Mkn 335 is remarkable because it has repeatedly shown deep, long X-ray low states that show pronounced spectral structure. It has become one of the prototype active galactic nuclei (AGNs) in deep minimum X-ray states. Here we report on the continuation of our ongoing monitoring campaign with Swift and the examination of the low-state X-ray spectra based on a 200 ks triggered observation with XMM-Newton in 2009 June. Swift has continuously monitored Mkn 335 since 2007 May typically on a monthly basis. This is one of the longest simultaneous UV/X-ray light curves so far obtained for an AGN. Mkn 335 has shown strong X-ray variability even on timescales of hours. In the UV, it turns out to be one of the most variable among NLS1s. Long-term Swift monitoring allows us to examine correlations between the UV, X-rays, and X-ray hardness ratios. We find no significant correlation or lag between the UV and X-ray variability; however, we do find distinct trends in the behavior of the hardness ratio variability. The hardness ratio and count rate are correlated in the low-flux state, but no correlation is seen in the high state. The X-ray low-state spectra of the 2007 and 2009 XMM-Newton observations display significant spectral variability. We fit the X-ray spectra with a suite of phenomenological models in order to characterize the data. The broadband CCD spectrum can be fitted equally well with partial absorption and blurred reflection models. These more complicated models are explored in further detail in upcoming work.

79 ASTRONOMY AND ASTROPHYSICS↗

SPECTRAL OPTICAL MONITORING OF THE NARROW-LINE SEYFERT 1 GALAXY Ark 564

We present the results of a long-term (1999-2010) spectral optical monitoring campaign of the active galactic nucleus (AGN) Ark 564, which shows a strong Fe II line emission in the optical. This AGN is a narrow-line Seyfert 1 (NLS1) galaxy, a group of AGNs with specific spectral characteristics. We analyze the light curves of the permitted H{alpha}, H{beta}, optical Fe II line fluxes, and the continuum flux in order to search for a time lag between them. Additionally, in order to estimate the contribution of iron lines from different multiplets, we fit the H{beta} and Fe II lines with a sum of Gaussian components. We find that during the monitoring period the spectral variation (F{sub max}/F{sub min}) of Ark 564 is between 1.5 for H{alpha} and 1.8 for the Fe II lines. The correlation between the Fe II and H{beta} flux variations is of higher significance than that of H{alpha} and H{beta} (whose correlation is almost absent). The permitted-line profiles are Lorentzian-like and do not change shape during the monitoring period. We investigate, in detail, the optical Fe II emission and find different degrees of correlation between the Fe II emission arising from different spectral multiplets and the continuum flux. The relatively weak and different degrees of correlations between permitted lines and continuum fluxes indicate a rather complex source of ionization of the broad-line emission region.

79 ASTRONOMY AND ASTROPHYSICS↗

ORBITAL MONITORING OF THE ASTRALUX LARGE M-DWARF MULTIPLICITY SAMPLE

Orbital monitoring of M-type binaries is essential for constraining their fundamental properties. This is particularly useful in young systems, where the extended pre-main-sequence evolution can allow for precise isochronal dating. Here, we present the continued astrometric monitoring of the more than 200 binaries of the AstraLux Large Multiplicity Survey, building both on our previous work, archival data, and new astrometric data spanning the range of 2010-2012. The sample is very young overall—all included stars have known X-ray emission, and a significant fraction (18%) of them have recently also been identified as members of young moving groups in the solar neighborhood. We identify ∼30 targets that both have indications of being young and for which an orbit either has been closed or appears possible to close in a reasonable time frame (a few years to a few decades). One of these cases, GJ 4326, is, however, identified as probably being substantially older than has been implied from its apparent moving group membership, based on astrometric and isochronal arguments. With further astrometric monitoring, these targets will provide a set of empirical isochrones, against which theoretical isochrones can be calibrated, and which can be used to evaluate the precise ages of nearby young moving groups.

79 ASTRONOMY AND ASTROPHYSICS↗

Correlation analysis on real-time tab-delimited network monitoring data

End-End performance monitoring in the Internet, also called PingER is a part of SLAC National Accelerator Laboratory’s research project. It was created to answer the growing need to monitor network both to analyze current performance and to designate resources to optimize execution between research centers, and the universities and institutes co-operating on present and future operations. The monitoring support reflects the broad geographical area of the collaborations and requires a comprehensive number of research and financial channels. The data architecture retrieval and methodology of the interpretation have emerged over numerous years. Analyzing this data is the main challenge due to its high volume. Finally, by using correlation analysis, we can make crucial conclusions about how the network data affects the performance of the hosts and how it depends from countries to countries.

97 MATHEMATICS AND COMPUTING↗