Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Neutron spectroscopy by thermalization light yield measurement in a composite heterogeneous scintillator

An exothermic neutron capture reaction can be used to uniquely identify neutrons in particle detectors. With the use of a capture-gated coincidence technique, the sequence of scatter events that lead to neutron thermalization prior to the neutron capture can also be used to measure neutron energy. We report on the measurement of thermalization light yield via a time-of-flight technique in a polyvinyl toluene-based scintillator EJ-290 within a heterogeneous composite detector that also includes 6Li-doped glass scintillator. The thermalization light output exhibits a strong correlation with neutron energy because of the preference for near-complete energy deposition prior to the 6Li(n,t)4He neutron capture reaction. The nonproportionality of the light yield from nuclear recoils contributes to the observed broadening of the distribution of thermalization light output. The nonproportional dependence of the scintillation light output in the EJ-290 scintillator as a function of proton recoil energy has been characterized in the range of 0.3–14.1 MeV via the Birks parametrization through a combination of time-of-flight measurement and previously conducted measurements with Monoenergetic neutron sources.

6Li-doped scintillator↗

A compact neutron spectrometer system

A portable neutron spectrometer, nSpec, has been developed for passive interrogation of fast neutrons ( 1 MeV) from neutron sources. The design of the system includes four EJ-301 liquid scintillation cells, a custom stand, and tungsten caps for gamma-ray shielding. Data acquisition settings were optimized to provide a dynamic range of up to > 15 MeV neutron energy. Additionally, the detector response matrix was characterized using a time-of-flight method based on gamma-ray tagged neutron emission from 252 Cf. The spectrum unfolding was characterized using measured and simulated spectra of AmBe and 252 Cf with the GRAVEL and MLEM methods. Monte Carlo methods were used to examine the uncertainty propagation and determine sufficient counts for a measurement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A diamond 14 MeV neutron energy spectrometer with high energy resolution

A self-standing single-crystal chemical vapor deposited diamond was obtained using lift-off method. It was fabricated into a radiation detector and response function measurements for 14 MeV neutrons were taken at the fusion neutronics source. 1.5% of high energy resolution was obtained by using the {sup 12}C(n, α){sup 9}Be reaction at an angle of 100° with the deuteron beam line. The intrinsic energy resolution, excluding energy spreading caused by neutron scattering, slowing in the target and circuit noises was 0.79%, which was also the best resolution of the diamond detector ever reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deuteron breakup induced by 14-MeV neutrons from inertial confinement fusion

Measurements are reported for the angle-averaged double-differential cross section $\langle$d 2 σ/dE n dΩ n $\rangle$ 0°< θ < 7.4° for the breakup reaction 2 H ($n,2n$) 1 H, induced by 14-MeV neutrons generated using an inertial confinement fusion platform. A bright neutron source, created on the OMEGA Laser System [Boehly et al., Opt. Commun. 133, 495 (1997)] with a luminosity of L = 10 24 s -1 , was used to irradiate deuterated targets. The absolute yields and energy spectra from the breakup neutrons emitted in a forward-angle geometry (θ = 0° to 7.4°) were detected with a sensitive, high-dynamic-range neutron time-of-flight spectrometer. The cross-section data, measured for neutron energy range from 0.5 to 10 MeV, is well reproduced by a theoretical calculation employing realistic nucleon–nucleon and three-nucleon forces.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

DOSE RATE VERIFICATION FOR SNS SPENT STRUCTURES

Residual dose rate measurements were conducted on two Spallation Neutron Source spent structures, target vessel #13 and proton beam window #5, after extraction from their service locations. These measurements were used to verify calculation methods for radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation. Neutronics analyses for predicting residual dose rates were carried out using complex and rigorous geometric models of the structures and their surroundings. Calculational results were analyzed and compared to the measured dose rates

Popova, Irina I.↗

Neutron flux from a 14-MeV neutron generator with tungsten filter for research in NDA methods for nuclear safeguards and security

The Joint Research Centre has taken into operation a new experimental device designed for research in the fields of nuclear safeguards and security applications. The research projects currently undertaken include detection of shielded contraband materials, detection of fissile materials, and mass determination of small fissile materials in shielded containers. The device, called the Pulsed Neutron Interrogation Test Assembly (PUNITA), incorporates a pulsed 14-MeV (D-T) neutron generator and a large graphite mantle surrounding the sample cavity. By pulsing the neutron generator with a frequency in the range of 10 to 150 Hz, a sample may be interrogated first by fast neutrons and a few hundred micro-seconds later by a pure thermal neutron flux. The permanent detection systems incorporated in PUNITA include {sup 3}He neutrons detectors, HPGe gamma detectors, and lanthanum bromide scintillation detectors.We have studied the effects of placing a tungsten liner around the neutron generator target. The 14-MeV neutrons induce (n, 2n) and (n, 3n) reactions. In addition the mean neutron energy emitted from generator/tungsten assembly is reduced to about 1 MeV. Both of these effects increase the thermal neutron flux in the sample cavity. The paper describes the observed advantages of the tungsten liner with respect to increase in thermal flux, and better shielding capabilities of the nearby gamma and neutron detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-resolution neutron spectroscopy using backscattering and neutron spin-echo spectrometers in soft and hard condensed matter

The instruments best suited to performing high-energy-resolution neutron spectroscopy are spin-echo spectrometers and backscattering spectrometers. The development of these experimental techniques dates back almost half a century, and most major neutron scattering facilities operate mature spectrometers of one or both classes. Recent advances in instrumentation and neutron sources are enhancing their performance and expanding their capabilities, with the objective of enabling researchers to tackle new and more complex problems. Finally, in this Technical Review, we assess the current state of the art in high-energy-resolution neutron spectrometers, showcasing their role in the study of nanoscale dynamics in soft and biological materials, as well as disordered magnets.

47 OTHER INSTRUMENTATION↗

M1 and E1 transition cross sections in D(y->,n) reactions near reaction threshold

M1 and E1 transition cross sections in the D(y->, n) reaction were separately determined by measuring the analyzing power for emitted neutrons with linearly-polarized gamma rays at four energies between 2.26 MeV and 3.70 MeV near reaction threshold at 2.224 MeV. We compared the experimental result with the JENDL evaluated data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Epithermal Neutron Activation Analysis of the Asian Herbal Plants

Asian medicinal herbs Chrysanthemum (Spiraea aquilegifolia Pall.) and Red Sandalwood (Pterocarpus Santalinus) are widely used in folk and Ayurvedic medicine for healing and preventing some diseases. The modern medical science has proved that the Chrysanthemum (Spiraea aquilegifolia Pall.) possesses the following functions: reducing blood press, dispelling cancer cell, coronary artery's expanding and bacteriostating and Red Sandalwood (Pterocarpus Santalinus) is recommended against headache, toothache, skin diseases, vomiting and sometimes it is taken for treatment of diabetes. Species of Chrysanthemums were collected in the north-eastern and central Mongolia, and the Red Sandalwood powder was imported from India. Samples of Chrysanthemums (branches, flowers and leaves)(0.5 g) and red sandalwood powder (0.5 g) were subjected to the multi-element instrumental neutron activation analysis using epithermal neutrons (ENAA) at the IBR-2 reactor, Frank Laboratory of Neutron Physics (FLNP) JINR, Dubna. A total of 41 elements (Na, Mg, Al, Cl, K, Ca, Sc, V, Cr, Mn, Fe, Co, Ni, Zn, As, Se, Br, Rb, Sr, Zr, Mo, Cd, Cs, Ba, La, Hf, Ta, W, Sb, Au, Hg, Ce, Nd, Sm, Eu, Tb, Dy, Yb, Th, U, Lu) were determined. For the first time such a large group of elements was determined in the herbal plants used in Mongolia. The quality control of the analytical results was provided by using certified reference material Bowen Cabbage. The results obtained are compared to the ''Reference plant? data (B. Markert, 1992) and interpreted in terms of excess of such elements as Se, Cr, Ca, Fe, Ni, Mo, and rare earth elements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Relativistic Processes and the Internal Structure of Neutron Stars

Models for the internal composition of Dense Compact Stars are reviewed as well as macroscopic properties derived by observations of relativistic processes. Modeling of pure neutron matter Neutron Stars is presented and crust properties are studied by means of a two fluid model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-energy inelastic neutron scattering data taken at the SEQUOIA spectrometer.

INS measurements were performed using the Fine Resolution Chopper Spectrometer SEQUOIA at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory. A powder sample of SrCoGe2O6 was loaded in an aluminum can for the measurements and a CCR was used to cool the sample down to 6 K. Data were collected using fixed incident neutron energies of 100 and 30 meV.

MATERIALS SCIENCE↗

Analysis of the Temporal Response of Coupled Asymmetrical Zero-Power Subcritical Bare Metal Reactor Systems

The behavior of symmetrical coupled-core systems has been extensively studied, yet there is a dearth of research on asymmetrical systems due to the increased complexity of the analysis of such systems. In this research, the multipoint kinetics method is applied to asymmetrical zeropower, subcritical, bare metal reactor systems. Existing research on asymmetrical reactor systems assumes symmetry in the neutronic coupling; however, it will be shown that this cannot always be assumed. Deep subcriticality adds another layer of complexity and requires modification of the multipoint kinetics equations to account for the effect of the external neutron source. A modified set of multipoint kinetics equations is derived with this in mind. Subsequently, the Rossi-alpha equations are derived for a two-region asymmetrical reactor system. The predictive capabilities of the radiation transport code MCNP6 for neutron noise experiments are shown in a comparison to the results of a series of Rossi-alpha measurements performed by J. Mihalczo utilizing a coupled set of symmetrical bare highly-enriched uranium (HEU) cylinders. The ptrac option within MCNP6 can generate time-tagged counts in a cell (list-mode data). The list-mode data can then be processed similarly to measured data to obtain values for system parameters such as the dual prompt neutron decay constants observable in a coupled system. The results from the ptrac simulations agree well with the historical measured values. A series of case studies are conducted to study the effects of geometrical asymmetry in the coupling between two bare metal HEU cylinders. While the coupling behavior of symmetrical systems has been reported on extensively, that of asymmetrical systems remains sparse. In particular, it appears that there has been no previous research in obtaining the coupling time constants for asymmetrically-coupled systems. The difficulty in observing such systems is due in part to the inability to determine the individual coupling coefficients from measurement: unlike the symmetrical cases, only the product of the values can be obtained. A method is proposed utilizing MCNP6 tally ratios to separate the coupling coefficients for such systems. This work provides insight into the behavior of asymmetrically-coupled systems as the separation distance between the two cores is changed and also as the asymmetry is increased. As the asymmetry increases, both the slower and the faster observable prompt neutron decay constants increase in magnitude. The coupling time constants are determined from the measured decay constants. As the separation distance increases, both coupling coefficients decrease as expected. Based on these findings, an effective computational method utilizing MCNP6 and the Rossialpha technique can be applied to the prediction of asymmetrical coupled system measurements.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hydrogen Cylinder Storage Array Explosion Evaluations at the High Flux Isotope Reactor

The safety analysis for a recently-installed cold neutron source at the High Flux Isotope Reactor (HFIR) involved evaluation of potential explosion consequences from accidental hydrogen jet releases that could occur from an array of hydrogen cylinders. The scope of the safety analysis involved determination of the release rate of hydrogen, the total quantity of hydrogen assumed to be involved in the explosion, the location of an ignition point or center of the explosion from receptors of interest, and the peak overpressure at the receptors. To evaluate the total quantity of hydrogen involved in the explosion, a 2D model was constructed of the jet concentration and a radial-axial integral over the jet cloud from the centerline to the flammability limit of 4% was used to determine the hydrogen mass to be used as a source term. The location of the point source was chosen as the peak of the jet centerline concentration profile. Consequences were assessed using a combination of three methods for estimating local overpressure as a function of explosion source strength and distance: the Baker-Strehlow method, the TNT-equivalence method, and the TNO method. Results from the explosions were assessed using damage estimates in screening tables for buildings and industrial equipment.

08 HYDROGEN↗

Fifteen years of the Protein Crystallography Station: The coming of age of macromolecular neutron crystallography

The Protein Crystallography Station (PCS), located at the Los Alamos Neutron Scattering Center (LANSCE), was the first macromolecular crystallography beamline to be built at a spallation neutron source. Following testing and commissioning, the PCS user program was funded by the Biology and Environmental Research program of the Department of Energy Office of Science (DOE-OBER) for 13 years (2002–2014). The PCS remained the only dedicated macromolecular neutron crystallography station in North America until the construction and commissioning of the MaNDi and IMAGINE instruments at Oak Ridge National Laboratory, which started in 2012. The instrument produced a number of research and technical outcomes that have contributed to the field, clearly demonstrating the power of neutron crystallography in helping scientists to understand enzyme reaction mechanisms, hydrogen bonding and visualization of H-atom positions, which are critical to nearly all chemical reactions. During this period, neutron crystallography became a technique that increasingly gained traction, and became more integrated into macromolecular crystallography through software developments led by investigators at the PCS. As a result, this review highlights the contributions of the PCS to macromolecular neutron crystallography, and gives an overview of the history of neutron crystallography and the development of macromolecular neutron crystallography from the 1960s to the 1990s and onwards through the 2000s.

59 BASIC BIOLOGICAL SCIENCES↗

The nEDM experiment at the SNS

The nEDM collaboration proposes to measure the neutron electric dipole moment at the Spallation Neutron Source (Oak Ridge National Laboratory). The nEDM is a clear signature of CP violation. According to the Standard Model the nEDM is very small (∼10{sup −31} e cm), but many theories predict much higher values. In the proposed experiment polarized cold neutrons from the SNS would be trapped in liquid helium at a temperature of about 400 mK. The neutron spin would precess in a very uniform magnetic field (H ∼ 30 mG), and the experiment would measure the change in the precession frequency when a very strong electric field (E ∼ 50 kV/cm) is applied. Polarized {sup 3}He atoms serve as a co-magnetometer. The goal of the experiment is to measure the nEDM with an accuracy of ∼9 × 10{sup −28} e cm, which is more than an order of magnitude better than existing results.

43 PARTICLE ACCELERATORS↗

Resonant neutron scattering lengths

Unlike most of the periodic table, many rare-earth elements display considerable resonant scattering for thermal neutrons. Although this property is accompanied by strong neutron absorption, modern high-intensity neutron sources make diffraction experiments possible with these elements. Computation of scattering intensities is accomplished by fitting the variation in resonant scattering lengths ( b 0 , b ′ and b ′′) to a semi-empirical Breit–Wigner formalism, which can be evaluated over the range of neutron energies useful for diffraction, typically E = 10–600 meV; λ = 0.4–2.8 Å (with good extrapolation to longer wavelengths).

Von Dreele, Robert B. (ORCID:0000000253390634)↗

Health Physics Research Reactor Criticality Accident Alarm System Benchmark Overview [Slides]

This presentation discusses the Health Physics Research Reactor (HPRR) or Fast Burst Reactor (FBR) and how available data from Health Physics Research Reactor (HPRR) operation to can be used to create a benchmark report for inclusion in the ICSBEP, as a Criticality Accident Alarm System (CAAS) shielding benchmark. The evaluation of experimental data is also presented, specifically four experimental candidates are considered of potential value for the benchmark: 1. Neutron source estimation from a HPRR pulse (energy spectrum, fission yield), 2. Threshold Detector Unit (TDU) measurements at different distances from a HPRR pulse, shielded and unshielded, 3. Sulfur pellet activation at different distances from a HPRR pulse, shielded and unshielded, and 4. Total neutron fluence from a HPRR pulse measured by Bonner Sphere Spectrometry, shielded and unshielded. Additionally, a benchmark model overview is discussed as are sample calculation results.

61 RADIATION PROTECTION AND DOSIMETRY↗

Fast Neutron Spectroscopy with Organic Scintillation Detectors in a High-Radiation Environment

Organic scintillators with pulse shape discrimination capability are widely used in both research and practical applications of neutron detection. The neutron and gamma-ray identification performance of the detector depends on the classification algorithms, noise filters and pileup rejection criteria in a high-flux bremsstrahlung radiation environment. In this paper, a technique has been developed and implemented for the neutron detection with multiple filter and discrimination steps, which to a high confidence level eliminates counting of gamma-ray pulses. Such a technique is merited when making measurements in a high flux bremsstrahlung and secondary fluorescence environment. The EJ-309 and stilbene detectors coupled to the digital data acquisition system were used for the calibration assessments with standard gamma-ray and neutron sources such as 137Cs, 60Co, 252Cf, and Am-Be. The MCNPX-PoliMi and GEANT4 toolkits were used to simulate the light output and the optical photon transport in the scintillators and create detector response functions for each type of detector. The neutron spectrum unfolding algorithm, GRAVELW, was used to recreate and calibrate with the Am-Be as final step before applying the neutron detection system to extract fusion neutron spectra generated in an intense bremsstrahlung radiation environment. This new technique described offers the user the ability to measure neutron spectra in a high-flux gamma-ray field and tune the parameters to meet required filtering needs.

Neutron Detector, Organic Scintillator, PulseShape↗