At least 1,711 records · Page 95

Development of an Assessment Method for Radiation Exposure from NORM in Construction Materials - 19032

Once radiological impact is usually considered to be related to nuclear energy accidents and atomic bombs, most of the research on radiation protection has been focused on artificial radionuclides and radioactive waste. Less attention had been given to radiation exposure due to the presence of naturally occurring radioactive materials in raw materials usually considered as not radioactive and used in manufacturing of many building materials. At national level, radiological data from building materials is not available as the control of building materials regarding the content of naturally occurring radionuclides is addressed for the first time in the EU Directive 2013/59/EURATOM. At international level the research developed is largely incomplete: data on the activity concentration measurements of Ra-226, Th-232 and K-40 in building materials used in the construction industry in the EU is non-statistically representative. The data collected are not enough to have an idea of the European situation, but they confirm high concentration of Ra-226, Th-232 and K-40, in some cases. Moreover, most of the research studies carried out in the EU are based on the assessment of the activity concentration index, which was derived for practical monitoring purposes to identify whether a dose criterion is met; to be used only as a screening tool for identifying materials which might be of concern. The dose criterion considers only effective dose due to γ-radiation, but population at home is also exposed to Rn-222 (and Rn-220) from soil, water and building material itself, sometimes to β radiation from superficial materials, and even to Cs-137 from some types of wood. The indoors exposure can be actually much higher than the value assessed with the dose criterion method. Also, in most cases toxic and radioactive components are inseparably. Therefore, all technical questions related to the toxic part of these materials should be addressed: an integrated approach is needed to assess the impacts of using these materials (new materials, recyclates and by-products). Until recently, radiation from natural sources seemed both unremarkable and unalterable - a background phenomenon. It is now known that doses from natural sources and in particular, decay products of radon can be remarkably high within houses in some areas. Therefore, concerning exposure to natural radiation sources, special provisions have been laid down in the EU Directive 1996/28 EURATOM. Still, the radiological evaluation of building materials was not mandatory in this Directive. The most recent EU Directive 2013/59/EURATOM brings some changes concerning the exposure to natural occurring radioactive materials but the previous screening method was kept. An effective dose of 1 mSv/year was set, as a basis for the exposure to radionuclides of natural origin (except for radon). This work seeks to develop an integrated radiological and chemical-mineralogical assessment methodology for realistic exposure scenarios concerning different types of raw materials, by-products and recyclates and used as building materials. The methodology includes the characterization of selected materials accounting for radiological exposure - calculation of effective dose; toxicity assessment - determination of chemical composition and leaching tests, study of changes in the microstructure and consequently in the radon emanation coefficient. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Orsphere: Physics Measurments For Bare, HEU(93.2)-Metal Sphere

In the early 1970s Dr. John T. Mihalczo (team leader), J.J. Lynn, and J.R. Taylor performed experiments at the Oak Ridge Critical Experiments Facility (ORCEF) with highly enriched uranium (HEU) metal (called Oak Ridge Alloy or ORALLOY) in an attempt to recreate GODIVA I results with greater accuracy than those performed at Los Alamos National Laboratory in the 1950s (HEU-MET-FAST-001). The purpose of the Oak Ridge ORALLOY Sphere (ORSphere) experiments was to estimate the unreflected and unmoderated critical mass of an idealized sphere of uranium metal corrected to a density, purity, and enrichment such that it could be compared with the GODIVA I experiments. “The very accurate description of this sphere, as assembled, establishes it as an ideal benchmark for calculational methods and cross-section data files” (Reference 1). While performing the ORSphere experiments care was taken to accurately document component dimensions (±0.0001 inches), masses (±0.01 g), and material data. The experiment was also set up to minimize the amount of structural material in the sphere proximity. Two, correlated spheres were evaluated and judged to be acceptable as criticality benchmark experiments. This evaluation is given in HEU-MET-FAST-100. The second, smaller sphere was used for additional reactor physics measurements. Worth measurements (Reference 1, 2, 3 and 4), the delayed neutron fraction (Reference 3, 4 and 5) and surface material worth coefficient (Reference 1 and 2) are all measured and judged to be acceptable as benchmark data. The prompt neutron decay (Reference 6), relative fission density (Reference 7) and relative neutron importance (Reference 7) were measured, but are not evaluated. Information for the evaluation was compiled from References 1 through 7, the experimental logbooks 8 and 9 ; additional drawings and notes provided by the experimenter; and communication with the lead experimenter, John T. Mihalczo.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Brain necrosis after fractionated radiation therapy: Is the halftime for repair longer than we thought?

Purpose: To derive a radiobiological model that enables the estimation of brain necrosis and spinal cord myelopathy rates for a variety of fractionation schemes, and to compare repair effects between brain and spinal cord. Methods: Sigmoidal dose response relationships for brain radiation necrosis and spinal cord myelopathy are derived from clinical data using nonlinear regression. Three different repair models are considered and the repair halftimes are included as regression parameters. Results: For radiation necrosis, a repair halftime of 38.1 (range 6.9-76) h is found with monoexponential repair, while for spinal cord myelopathy, a repair halftime of 4.1 (range 0-8) h is found. The best-fit alpha beta ratio is 0.96 (range 0.24-1.73)Conclusions: A radiobiological model that includes repair corrections can describe the clinical data for a variety of fraction sizes, fractionation schedules, and total doses. Modeling suggests a relatively long repair halftime for brain necrosis. This study suggests that the repair halftime for late radiation effects in the brain may be longer than is currently thought. If confirmed in future studies, this may lead to a re-evaluation of radiation fractionation schedules for some CNS diseases, particularly for those diseases where fractionated stereotactic radiation therapy is used.

60 APPLIED LIFE SCIENCES↗

Comparison of maximal Rubidium-82 activities for myocardial blood flow quantification between digital and conventional PET systems

Background: PET-based myocardial blood flow (MBF) quantification can be inaccurate when using high tracer activities. Our aim was to derive the maximal Rubidium-82 activity for MBF assessment using a new digital PET system and compare the results with conventional analog systems. Methods: 1.8 GBq Rubidium-82 was injected into the cardiac insert of an anthropomorphic torso phantom. Data were acquired for 10 min using an Ingenuity TF (Philips Healthcare), Discovery 690 (D690, GE Healthcare), and digital PET prototype system (Philips Healthcare). The dynamic ranges, defined as the maximal measured activity in the reconstructed images deviating < 10% from the true present activity, were determined in all scans. Results: The dynamic ranges were 312 MBq for Ingenuity TF, 650 MBq for D690, and 654 MBq for digital PET prototype. Conclusions: The maximal Rb-82 activity for MBF assessment using digital PET prototype is higher than that for its analog counterpart (Ingenuity TF), but seems comparable to the D690.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

GEN-IV Benchmarking of Triso Fuel Performance Models under accident conditions modeling input data

This document presents the benchmark plan for the calculation of particle fuel performance on safety testing experiments that are representative of operational accidental transients. The benchmark is dedicated to the modeling of fission product release under accident conditions by fuel performance codes from around the world, and the subsequent comparison to post-irradiation experiment (PIE) data from the modeled heating tests. The accident condition benchmark is divided into three parts: • The modeling of a simplified benchmark problem to assess potential numerical calculation issues at low fission product release. • The modeling of the AGR-1 and HFR-EU1bis safety testing experiments. • The comparison of the AGR-1 and HFR-EU1bis modeling results with PIE data. The simplified benchmark case, thereafter named NCC (Numerical Calculation Case), is derived from “Case 5” of the International Atomic Energy Agency (IAEA) Coordinated Research Program (CRP) on coated particle fuel technology [IAEA 2012]. It is included so participants can evaluate their codes at low fission product release. “Case 5” of the IAEA CRP-6 showed large code-to-code discrepancies in the release of fission products, which were attributed to “effects of the numerical calculation method rather than the physical model” [IAEA 2012]. The NCC is therefore intended to check if these numerical effects subsist. The first two steps imply the involvement of the benchmark participants with a modeling effort following the guidelines and recommendations provided by this document. The third step involves the collection of the modeling results by Idaho National Laboratory (INL) and the comparison of these results with the available PIE data. The objective of this document is to provide all necessary input data to model the benchmark cases, and to give some methodology guidelines and recommendations in order to make all results suitable for comparison with each other. The participants should read this document thoroughly to make sure all the data needed for their calculations is provided in the document. Missing data will be added to a revision of the document if necessary. 09/2016: Tables 6 and 8 updated. AGR-2 input data added

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Covariance Matrix Evaluations for Independent Mass Fission Yields

Recent needs for more accurate fission product yields include covariance information to allow improved uncertainty estimations of the parameters used by design codes. The aim of this work is to investigate the possibility to generate more reliable and complete uncertainty information on independent mass fission yields. Mass yields covariances are estimated through a convolution between the multi-Gaussian empirical model based on Brosa's fission modes, which describe the pre-neutron mass yields, and the average prompt neutron multiplicity curve. The covariance generation task has been approached using the Bayesian generalized least squared method through the CONRAD code. Preliminary results on mass yields variance-covariance matrix will be presented and discussed from physical grounds in the case of {sup 235}U(n{sub th}, f) and {sup 239}Pu(n{sub th}, f) reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scale-up of high specific activity 186g Re production using graphite-encased thick 186 W targets and demonstration of an efficient target recycling process

Production of high specific activity 186g Re is of interest for development of theranostic radiopharmaceuticals. Previous studies have shown that high specific activity 186g Re can be obtained by cyclotron irradiation of enriched 186 W via the 186 W(d,2n) 186g Re reaction, but most irradiations were conducted at low beam currents and for short durations. In this paper, enriched 186 W metal targets were irradiated at high incident deuteron beam currents to demonstrate production rates and contaminants produced when using thick targets. Full-stopping thick targets, as determined using SRIM, were prepared by uniaxial pressing of powdered natural abundance W metal or 96.86% enriched 186 W metal encased between two layers of graphite flakes for target material stabilization. An assessment of structural integrity was made on each target preparation. To assess the performance of graphite-encased thick 186 W metal targets, along with the impact of encasing on the separation chemistry, targets were first irradiated using a 22 MeV deuteron beam for 10 min at 10, 20, and 27 μA, with an estimated nominal deuteron energy of 18.7 MeV on the 186 W target material (after energy degradation correction from top graphite layer). Gamma-ray spectrometry was performed post EOB on all targets to assess production yields and radionuclidic byproducts. The investigation also evaluated a method to recover and recycle enriched target material from a column isolation procedure. Material composition analyses of target materials, pass-through/wash solutions and recycling process isolates were conducted with SEM, FTIR, XRD, EDS and ICP-MS spectrometry. Finally, to demonstrate scaled-up production, a graphite-encased 186 W target made from recycled 186 W was irradiated for ~2 h with 18.7 MeV deuterons at a beam current of 27 μA to provide 0.90 GBq (24.3 mCi) of 186g Re, decay-corrected to the end of bombardment. ICP-MS analysis of the isolated 186g Re solution provided data that indicated the specific activity of 186g Re in this scaled-up production run was 2.6±0.5 GBq/μg (70±10 Ci/mg).

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Monitoring Cyp2b10 mRNA expression at cessation of 2-year carcinogenesis bioassay in mouse liver provides evidence for a carcinogenic mechanism devoid of human relevance: The dalcetrapib experience

Introduction: Dalcetrapib is a cholesteryl ester transfer protein (CETP) modulator in clinical assessment for cardiovascular outcome benefits. In compliance with regulatory requirements, dalcetrapib was evaluated in rodent 2-year carcinogenesis bioassays. In the mouse bioassay, male mice demonstrated increased liver weight and statistically increased incidences of hepatocellular adenoma/carcinoma. Hepatic cytochrome p450 (Cyp) 2b10 mRNA induction and increased Cyp2b10 enzyme activity signify activation of hepatic nuclear receptor constitutive androstane receptor (CAR), a widely established promoter of rodent-specific hepatic tumors. We therefore monitored hepatic Cyp2b10 mRNA and its enzyme activity in a subset of dalcetrapib-treated male mice from the bioassay. Methods: Liver samples were obtained from ∼ 1/3 of male mice from each dose group including vehicle-controls (mean and earliest study day of death 678 and 459 respectively). Quantitative real time PCR (qRT-PCR) was performed to determine Cyp2b10 mRNA expression and Cyp1a-, Cyp2b10- and Cyp3a-selective activities were monitored. Results: Cyp2b10 mRNA was strongly induced by dalcetrapib with an expected wide inter-individual variation (5–1421-fold). Group average fold-induction versus vehicle-controls showed a dose-related increase from 48-fold (250 mg/kg/day) to 160-fold (750 mg/kg/day), which declined slightly at 2000 mg/kg/day (97-fold). Cyp enzyme activities showed approximate doubling of total Cyp P450 content per milligram protein and a 9-fold increase in Cyp2b10-selective pentoxyresorufin O-dealkylase activity (750 mg/kg/day). Discussion: These data from hepatic Cyp2b10 monitoring are strongly suggestive of CAR activation by dalcetrapib, a mechanism devoid of relevance towards hepatocarcinogenesis in humans; results show feasibility of Cyp2b10 as a surrogate marker for this mechanism at cessation of a carcinogenesis bioassay. -- Highlights: ► Liver tumors were induced in male mice by dalcetrapib in a 2-y study (bioassay). ► Cyp2b10 induction typifies activation of nuclear receptor CAR in mouse liver. ► First report of hepatic Cyp2b10 monitoring at the end of a mouse bioassay. ► Cyp2b10 induction supports CAR activation by dalcetrapib in mouse bioassay. ► CAR activation is a mechanism of hepatic tumorigenesis of no relevance to humans.

60 APPLIED LIFE SCIENCES↗

Completion Report for Model Evaluation Well ER-11-2: Corrective Action Unit 98: Frenchman Flat

Model Evaluation Well ER-11-2 was drilled for the U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office in support of Nevada Environmental Management Operations at the Nevada National Security Site (formerly known as the Nevada Test Site). The well was drilled in August 2012 as part of a model evaluation program in the Frenchman Flat area of Nye County, Nevada. The primary purpose of the well was to provide detailed geologic, hydrogeologic, chemical, and radionuclide data that can be used to test and build confidence in the applicability of the Frenchman Flat Corrective Action Unit flow and transport models for their intended purpose. In particular, this well was designed to provide data to evaluate the uncertainty in model forecasts of contaminant migration from the upgradient underground nuclear test PIN STRIPE, conducted in borehole U-11b in 1966. Well ER-11-2 will provide information that can be used to refine the Phase II Frenchman Flat hydrostratigraphic framework model if necessary, as well as to support future groundwater flow and transport modeling. The main 31.1-centimeter (cm) hole was drilled to a total depth of 399.6 meters (m). A completion casing string was not set in Well ER-11-2. However, a piezometer string was installed in the 31.1-cm open hole. The piezometer is composed of 7.3-cm stainless-steel tubing hung on 6.0-cm carbon-steel tubing via a crossover sub. The piezometer string was landed at 394.5 m, for monitoring the lower tuff confining unit. Data collected during and shortly after hole construction include composite drill cuttings samples collected every 3.0 m, various geophysical logs, water quality (including tritium and other test-related radionuclides) measurements, and water level measurements. The well penetrated 42.7 m of Quaternary and Tertiary alluvium and 356.9 m of Tertiary volcanic rock. The water-level measured in the piezometer string on September 25, 2012, was 353.8 m below ground surface. No tritium above levels detectable by field methods were encountered in this hole. No well development or hydrologic testing was conducted in this well immediately after completion, and future well development, sampling, and hydrologic testing planned for this well will be limited due to the diameter of the piezometer string. The stratigraphy, general lithology, and the water level are as expected, but the section of geology encountered is higher than expected due to faulting. No tritium above the minimum detection limit of the field equipment was detected because the target aquifer (the Topopah Spring aquifer) at Well ER-11-2 is structurally higher than expected and thus unsaturated.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Individualized Positron Emission Tomography–Based Isotoxic Accelerated Radiation Therapy Is Cost-Effective Compared With Conventional Radiation Therapy: A Model-Based Evaluation

Purpose: To evaluate long-term health effects, costs, and cost-effectiveness of positron emission tomography (PET)-based isotoxic accelerated radiation therapy treatment (PET-ART) compared with conventional fixed-dose CT-based radiation therapy treatment (CRT) in non-small cell lung cancer (NSCLC). Methods and Materials: Our analysis uses a validated decision model, based on data of 200 NSCLC patients with inoperable stage I-IIIB. Clinical outcomes, resource use, costs, and utilities were obtained from the Maastro Clinic and the literature. Primary model outcomes were the difference in life-years (LYs), quality-adjusted life-years (QALYs), costs, and the incremental cost-effectiveness and cost/utility ratio (ICER and ICUR) of PET-ART versus CRT. Model outcomes were obtained from averaging the predictions for 50,000 simulated patients. A probabilistic sensitivity analysis and scenario analyses were carried out. Results: The average incremental costs per patient of PET-ART were €569 (95% confidence interval [CI] €−5327-€6936) for 0.42 incremental LYs (95% CI 0.19-0.61) and 0.33 QALYs gained (95% CI 0.13-0.49). The base-case scenario resulted in an ICER of €1360 per LY gained and an ICUR of €1744 per QALY gained. The probabilistic analysis gave a 36% probability that PET-ART improves health outcomes at reduced costs and a 64% probability that PET-ART is more effective at slightly higher costs. Conclusion: On the basis of the available data, individualized PET-ART for NSCLC seems to be cost-effective compared with CRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Mechanical Recanalisation After Intravenous Thrombolysis in Acute Anterior Circulation Stroke: The Impact of a New Temporary Stent

Purpose: Treatment of acute stroke by endovascular mechanical recanalisation (EMR) has shown promising results and continues to be further refined. We evaluated the impact of a temporary stent compared with our results using other mechanical devices. Materials and Methods: We analysed clinical and radiological data of all patients who were treated by EMR after intravenous thrombolysis for acute carotid T- and middle-cerebral artery (M1) occlusions at our centre between 2007 and 2011. A comparison was performed between those patients in whom solely the stent-retriever was applied (group S) and those treated with other devices (group C). Results: We identified 14 patients for group S and 16 patients for group C. Mean age, National Institute of Health Stroke Scale score, and time to treatment were 67.1 years and 16.5 and 4.0 h for group S and 61.1 years and 17.6 and 4.5 h for group C, respectively. Successful recanalisation (thrombolysis in cerebral infarction scores {>=}IIb) was achieved in 93% of patients in group S and 56% of patients in group C (P < 0.05). Mean recanalisation times for M1 occlusions were 23 min (group S) and 29 min (group C) and for carotid-T occlusions were 39 min (group S) and 50 min (group C), and 45% of the patients in group S and 33% in group C had a favourable outcome (Modified Rankin Scale score {<=}2). Conclusion: The findings suggest an improvement in recanalisation success by the application of a temporary stent compared with previously used devices. These results are to be confirmed by larger studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Survival Impact of Adjuvant Radiation Therapy in Masaoka Stage II to IV Thymomas: A Systematic Review and Meta-analysis

Purpose: To evaluate the survival impact of postoperative radiation therapy (PORT) in stage II to IV thymomas, using systematic review and meta-analysis. Methods and Materials: A database search was conducted with EMBASE, PubMed, Web of Science, Cochrane Library, and Ovid from inception to August 2015. Thymic carcinomas were excluded, and studies comparing overall survival (OS) with and without PORT in thymomas were included. The hazard ratios (HRs) of OS were extracted, and a random-effects model was used in the pooled analysis. Results: Seven retrospective series with a total of 1724 patients were included and analyzed. Almost all of the patients underwent macroscopically complete resection, and thymoma histology was confirmed by the World Health Organization criteria. In the overall analysis of stage II to IV thymomas, OS was not altered with the receipt of PORT (HR 0.79, 95% confidence interval [CI] 0.58-1.08). Although PORT was not associated with survival difference in Masaoka stage II disease (HR 1.45, 95% CI 0.83-2.55), improved OS was observed with the addition of PORT in the discrete pooled analysis of stage III to IV (HR 0.63, 95% CI 0.40-0.99). Significant heterogeneity and publication bias were not found in the analyses. Conclusions: From the present meta-analysis of sole primary thymomas, we suggest the potential OS benefit of PORT in locally advanced tumors with macroscopically complete resection, but not in stage II disease. Further investigations with sufficient survival data are needed to establish detailed treatment indications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Medical Graduates in Radiation Oncology: Historical Trends and Comparison With Other Medical Specialties

Purpose: This is the first National Resident Matching Program analysis evaluating historical patterns of international medical graduates (IMGs) in radiation oncology (RO) and providing comparison with American (MD) medical graduates (AMGs), osteopathic students (DOs), unfilled positions, and other specialties. Methods and Materials: National Resident Matching Program data for IMGs were available from 2003 to 2015, with limited data for other specialty matches. The following RO-specific figures were obtained per year: total positions available; total matched positions; number of unfilled positions; and number of IMG, AMG, and DO matches. In addition, the number of IMG matches and total matched positions were obtained for 19 other specialties. Fisher exact tests and χ{sup 2} tests were considered significant at α <.05. Results: From 2010 to 2015, 0.8% of RO matches were IMGs, a decline from 2.4% in 2003 to 2009 (P=.006). Proportions of DO matches during these intervals increased by 40% (from 1.0% to 1.4%), significantly lower than IMGs for 2003 to 2009 (P=.03) but not 2010 to 2015 (P=.26). From 2003 to 2015, the percentage of IMG matches, at 1.5%, was significantly lower than the percentage of unfilled seats, at 3.5% (P<.001). In comparison with other specialties (2003-2015), RO had the fewest IMG matches (1.5%), followed by otolaryngology (1.9%) and orthopedics (2.2%); specialties with the highest IMG proportions were internal medicine (37.1%), family medicine (35.7%), and neurology (31.1%). Conclusions: Presently, IMGs represent <1% of RO matches, the lowest among major specialties. There are several speculative factors associated with this low proportion. There are significantly more unfilled positions than those filled by IMGs; programs at risk of not matching could weigh the advantages and disadvantages of interviewing IMGs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cone-Beam CT-Based Delineation of Stereotactic Lung Targets: The Influence of Image Modality and Target Size on Interobserver Variability

Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient. Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI{sub genA} = 0.62 {+-} 0.06 vs. CI{sub genB} = 0.70 {+-} 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability. Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Field-in-Field Technique for Total Body Irradiation

Purpose: To evaluate the clinical use of a field-in-field (FIF) technique for total body irradiation (TBI) using a treatment-planning system (TPS) and to verify TPS results with in vivo dose measurements using metal-oxide-semiconductor field-effect transistor (MOSFET) detectors. Methods and Materials: Clinical and dosimetric data of 10 patients treated with TBI were assessed. Certain radiation parameters were measured using homogenous and regular phantoms at an extended distance of 380 cm, and the results were compared with data from a conventional standard distance of 100 cm. Additionally, dosimetric validation of TPS doses was performed with a Rando phantom using manual calculations. A three-dimensional computed tomography plan was generated involving 18-MV photon beams with a TPS for both open-field and FIF techniques. The midline doses were measured at the head, neck, lung, umbilicus, and pelvis for both open-field and FIF techniques. Results: All patients received planned TBI using the FIF technique with 18-MV photon energies and 2 Gy b.i.d. on 3 consecutive days. The difference in tissue maximum ratios between the extended and conventional distances was <2%. The mean deviation of manual calculations compared with TPS data was +1.6% (range, 0.1-2.4%). A homogenous dose distribution was obtained with 18-MV photon beams using the FIF technique. The mean lung dose for the FIF technique was 79.2% (9.2 Gy; range, 8.8-9.7 Gy) of the prescribed dose. The MOSFET readings and TPS doses in the body were similar (percentage difference range, -0.5% to 2.5%) and slightly higher in the shoulder and lung (percentage difference range, 4.0-5.5%). Conclusion: The FIF technique used for TBI provides homogenous dose distribution and is feasible, simple, and spares time compared with more-complex techniques. The TPS doses were similar to the midline doses obtained from MOSFET readings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗