Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

BoxScore - A real-time beam-diagnosis program for the CAEN digitizer x730 series

BoxScore is a real-time beam diagnosis and monitoring program for the CAEN x730 series digitizer, developed for the ATLAS in-flight system at Argonne National Laboratory. The CAEN x730 series digitizer, with built-in Digital Pulse Processing for the Pulse-Height-Analysis, digitizes the input signal in real-time and processes it using a trapezoidal filter. BoxScore reads the digitizer’s buffer directly, builds and saves events to local files, plots histograms for particle identification, and outputs the rates of selected isotopes every second. Implementation of BoxScore has shortened the time needed for in-flight beam-tuning and has potential applications for other nuclear physics experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment of the associated particle technique with high-resolution gamma-ray spectroscopy for in-field identification of chemical warfare agents and explosives

In this work, high-resolution prompt γ-ray neutron activation analysis (PGNAA) is performed using the associated particle (AP) technique with a deuterium-tritium neutron generator and high-purity germanium detector. Although the time resolution is inferior compared to similar systems employing fast scintillation γ-ray detectors, the strong background suppression combined with the high γ-ray energy resolution provides an important boost in sensitivity to certain key elements, especially relevant to field measurements of complex chemicals encased within thick layers of metal, such as in the case of recovered chemical warfare (CW) munitions. Results for various CW and explosive simulants contained within mock munitions are presented and compared with results obtained from traditional PGNAA measurements without the aid of the AP technique. Significant improvements in identification and discrimination between certain chemicals are achieved with the high energy resolution AP technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of the 34 m Cl beam production at intermediate energies

Here the isomeric content of a 34 Cl beam produced in the intermediate-energy projectile fragmentation of a 150 MeV/u 36 Ar beam on a 3 mm-thick Be target was studied. β-delayed γ-ray spectroscopy was used to measure the population of 34 Cl fragments in the ground vs. isomeric states at zero degrees relative to the incoming primary beam for four different momentum settings of the fragment separator near the predicted central velocity of these fragments, as well as, at two non-zero-degree settings for one momentum setting. Of the settings explored, which excluded rigidities within 0.5% of the value predicted to maximize total 34 Cl yield due to unreacted primary beam, the maximum rate for the production of Cl was found at a rigidity setting 0.75% below the predicted peak 34 Cl yield. The maximum population of the isomeric state relative to the ground state was observed at a rigidity 1.25% below the predicted maximum 34 Cl yield. Studies such as this are important in generating the understanding needed for producing isomer-enriched rare-isotope beams.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accurate determination of the electron spin polarization in magnetized iron and nickel foils for Møller polarimetry

The Møller polarimeter in Hall A at Jefferson Lab in Newport News, VA, has provided reliable measurements of electron beam polarization for the past two decades. Past experiments have typically required polarimetry at the 1% level of absolute uncertainty which the Møller polarimeter has delivered. However, the upcoming proposed experimental program including MOLLER and SoLID have stringent requirements on beam polarimetry precision at the level of 0.4% (The MOLLER Collaboration, 2014; The SoLID collaboration, 2019), requiring a systematic re-examination of all the contributing uncertainties. Møller polarimetry uses the double polarized scattering asymmetry of a polarized electron beam on a target with polarized atomic electrons. The target is a ferromagnetic material magnetized to align the spins in a given direction. In Hall A, the target is a pure iron foil aligned perpendicular to the beam and magnetized out of plane parallel or antiparallel to the beam direction. The acceptance of the detector is engineered to collect scattered electrons close to 90° in the center of mass frame where the analyzing power is a maximum (-7/9). One of the leading systematic errors comes from determination of the target foil polarization. Polarization of a magnetically saturated target foil requires knowledge of both the saturation magnetization and g', the electron g-factor which includes components from both spin and orbital angular momentum from which the spin fraction of magnetization is determined. Target foil polarization has been previously addressed in a 1997 publication “A precise target for Møller polarimetry” by de Bever et al. (1997) at a level of precision sufficient for experiments up to this point. Several shortcomings with the previous published value require revisiting the result prior to MOLLER. Here, we utilize the existing world data to provide a best estimate for target polarization for both nickel and iron foils including uncertainties in magnetization, high-field and temperature dependence, and fractional contribution to magnetization from orbital effects. We determine the foil electron spin polarization at 294 K to be 0.08020 ± 0.00018 (@4 T applied field) for iron and 0.018845+/-0.000053 (@2 T applied field) for nickel. Finally, we conclude with a brief discussion of additional systematic uncertainties to Møller polarimetry using this technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact light shield for the Psyche gamma-ray spectrometer

A compact, low-mass light shield has been designed for the Psyche space mission high-purity germanium gamma-ray spectrometer. The spectrometer will be vented to space, which can allow solar photons to enter the cryostat and cause charge-induced noise. The light shield was designed to block more than 99.9% of solar photons while maintaining high molecular conductance to space vacuum. COMSOL simulations and experiments were performed to characterize light shield photon attenuation and molecular conductance. Finally, the light shield was integrated onto the gamma-ray spectrometer and photon suppression and vacuum performance were demonstrated.

(16) Psyche↗

Multi-modal tomographic imaging system for poolside characterization of nuclear test fuels: Design considerations and studies

Testing and qualification of advanced nuclear fuels involves an iterative process of prototyping, in-pile irradiation testing, and in-situ or ex-situ examination. Fuel restructuring and fission product migration during burnup are among the most important aspects of fuel evolution that affect several important performance characteristics such as heat removal, accident tolerance, and fission product retention. Pool-side non-destructive characterization techniques provide fuel developers with tools to understand fuel evolution at different points of burnup. A design for a compact, submersible, and multi-modal gamma-ray tomography system for imaging irradiated nuclear fuel is presented here. Detector selection, collimator geometry and fabrication, mechanical design, imaging protocol and acquisition speed are discussed. Modeling calculations show that sub-millimeter resolution can be achieved in both transmission computed tomography images as well as in emission computed tomography images in a matter of hours. Several design compromises and fabrication challenges are discussed which should be taken into consideration for future submersible gamma-ray tomography instruments.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

ECCE sensitivity studies for single hadron transverse single spin asymmetry measurements

Here, we performed feasibility studies for various single transverse spin measurements that are related to the Sivers effect, transversity and the tensor charge, and the Collins fragmentation function. The processes studied include semi-inclusive deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The data were obtained in pythia6 and geant4 simulated e+p collisions at 18 GeV on 275 GeV, 18 on 100, 10 on 100, and 5 on 41 that use the ECCE detector configuration. Typical DIS kinematics were selected, most notably Q 2 >1 GeV 2 , and cover the x range from 10 -4 to 1. The single spin asymmetries were extracted as a function of x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton, and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. They are obtained in azimuthal moments in combinations of the azimuthal angles of the hadron transverse momentum and transverse spin of the nucleon relative to the lepton scattering plane. In order to extract asymmetries, the initially unpolarized MonteCarlo was re-weighted in the true kinematic variables, hadron types and parton flavors based on global fits of fixed target SIDIS experiments and e + e – annihilation data. The expected statistical precision of such measurements is extrapolated to 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. Similar neutron information is obtained by comparing the ECCE e+p pseudo-data with the same from the EIC Yellow Report and scaling the corresponding Yellow Report e+ 3 He pseudo-data uncertainties accordingly. The impact on the knowledge of the Sivers functions, transversity and tensor charges, and the Collins function has then been evaluated in the same phenomenological extractions as in the Yellow Report. Finally, the impact is found to be comparable to that obtained with the parametrized Yellow Report detector and shows that the ECCE detector configuration can fulfill the physics goals on these quantities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Instrumentation for correlated prompt n – γ emission studies in coincidence with fission fragments

Recent theoretical and experimental results have brought renewed interest and focus on the topic of fission fragment angular momentum. Measurements of neutrons and rays in coincidence with fission fragments remain the most valuable tool in the exploration of fission physics. To achieve these scientific goals, we have developed a system that combines a state-of-the-art fission fragment detector and n – γ radiation detectors. A new twin Frisch-gridded ionization chamber has been designed and constructed for use with a spontaneous fission source and an array of forty trans-stilbene organic scintillators (FS-3) at Argonne National Laboratory. The new ionization chamber design we present in this work aims at minimizing particle attenuation in the chamber walls, and provides a compact apparatus that can be fit inside existing experimental systems. The ionization chamber is capable of measuring fission fragment masses and kinetic energies, whereas the FS-3 provides neutron and γ-ray multiplicities and spectra. Here, the details of both detector assemblies are presented along with the first experimental results of this setup. Planned event-by-event analysis and future experiments are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of 2.8 • 10 -4 to 4.1 • 10 -4 for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential η of 1.7 • 10 -4 to 3.3 • 10 -4 . Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. In conclusion, based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with η = 3.5(5)•10 -4 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Search for e → τ charged lepton flavor violation at the EIC with the ECCE detector

The recently approved Electron-Ion Collider (EIC) will provide a unique new opportunity for searches of charged lepton flavor violation (CLFV) and other new physics scenarios. In contrast to the e ↔ μ CLFV transition for which very stringent limits exist, there is still a relatively large discovery space for the e → τ CLFV transition, potentially to be explored by the EIC. Here, with the latest detector design of ECCE (EIC Comprehensive Chromodynamics Experiment) and projected integral luminosity of the EIC, we find the τ-leptons created in the DIS process ep → τX are expected to be identified with high efficiency. A first ECCE simulation study, restricted to the 3-prong τ-decay mode and with limited statistics for the Standard Model backgrounds, estimates that the EIC will be able to improve the current exclusion limit on e → τ CLFV by an order of magnitude. As a result, the very high vertex resolution of the ECCE detector configuration plays a critical role in τ identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECCE unpolarized TMD measurements

For this work, we performed feasibility studies for various measurements that are related to unpolarized TMD distribution and fragmentation functions for the ECCE detector proposal. The processes studied include semi-inclusive Deep inelastic scattering (SIDIS) where single hadrons (pions and kaons) were detected in addition to the scattered DIS lepton. The single hadron cross sections and multiplicities were extracted as a function of the DIS variables x and Q 2 , as well as the semi-inclusive variables z, which corresponds to the momentum fraction the detected hadron carries relative to the struck parton and P T , which corresponds to the transverse momentum of the detected hadron relative to the virtual photon. The expected statistical precision of such measurements is extrapolated to accumulated luminosities of 10 fb –1 and potential systematic uncertainties are approximated given the deviations between true and reconstructed yields. The expected uncertainties are then used to obtain the expected impact on the related TMD distribution and fragmentation functions. We find that the ECCE detector proposal fulfills the physics requirements on these channels as detailed in the EIC Yellow Report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation studies related to the particle identification by the forward and backward RICH detectors at Electron Ion Collider

The Electron-Ion collider (EIC) will be the ultimate facility to study the dynamics played by colored quarks and gluons in the phenomenology of nucleons and nuclei, described by Quantum Chromodynamics. The physics programs will greatly rely on efficient particle identification (PID) in both the forward and the backward regions. The forward and the backward RICHes of the EIC have to be able to cover wide acceptance and momentum ranges; in the forward region a dual radiator RICH (dRICH) is foreseen and in the backward region a proximity-focusing RICH can be foreseen to be employed. The geometry and the performance studies of the dRICH have been performed as prescribed in the EIC Yellow Report using the ATHENA software framework. Furthermore, this part of our work reports the effort following the call for EIC detector proposal and the studies related to the forward and the backward RICH performance. In the forward region, the dRICH performance showed a pion- kaon separation from around 1 GeV/c to 50 GeV/c at a three sigma level; the proximity focusing RICH (pfRICH) foreseen for the backward region can reach three sigma separation up to 3 GeV/c for e/$π$ and up to 10 GeV/c for $π$/K mass hypotheses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory

The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45 T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated plastic scintillator array manufacturing using fast-, photo-curable resin

Pixelated plastic scintillator arrays can serve as high efficiency and high resolution neutron imaging detectors. Manufacturing these arrays is intensive in both time and labor. This article presents a fabrication method based on additive manufacturing for two-dimensional plastic organic scintillator arrays using a custom-built automated assembly machine and a custom photocurable resin that has significant non-aromatic acrylate oligomer content. The process involves two main stages: fully autonomous production of one-dimensional layered arrays, followed by semi-autonomous cutting and stacking to form two-dimensional pixel arrays. One-dimensional arrays were manufactured at a rate of around 4 layers per hour with minimal defects and tight dimensional tolerances, while two-dimensional arrays up to 7 x 7 pixels and 70 mm in length were completed in approximately 3.5 hours. Final arrays exhibited dimensional deviations of less than 0.5 mm. Two-dimensional arrays read out by a multi-anode photomultiplier tube demonstrated per-pixel position resolution and pulse-shape discrimination, enabling gamma–neutron interaction separation in mixed radiation environments.

36 MATERIALS SCIENCE↗

Evaluation of the beam-induced depolarization of the HJET target at the EIC

The Polarized Atomic Hydrogen Gas Jet Target (HJET) has played a central role in the absolute calibration of proton beam polarization at RHIC and is foreseen as a key component of the hadron polarimetry program at the future Electron–Ion Collider (EIC). The substantially higher beam current, reduced bunch spacing, and shorter bunch length planned for EIC operation motivate a careful reassessment of possible beam-induced depolarization of the jet target. In this paper, the depolarization of ground-state hydrogen atoms caused by the time-dependent magnetic field of the circulating polarized proton beam is quantitatively evaluated. The hydrogen atom is treated as a four-level hyperfine system in a holding magnetic field, and transitions driven by harmonic components of the bunch-induced magnetic field are analyzed using time-dependent quantum-mechanical evolution along atomic trajectories. Numerical tracking of hydrogen atoms through the beam region is performed using nominal EIC beam parameters. It is shown that, for a holding field of 120 mT (as used at RHIC), the resulting depolarization of the jet target at the EIC is negligibly small, ≲ 0.01 %, and well below the level relevant for EIC polarization accuracy requirements. The stability of this result with respect to plausible variations of the EIC proton beam parameters is also evaluated. In addition, possible effects under alternative experimental conditions are also examined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗