Search NASA⌕ Search

SEARCH · Search NASA

Results for “Operating Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

LAMP Technical Readiness Evaluation Report (Rev. 1)

An internal preliminary evaluation of Critical Technology Elements (CTEs) for the LANSCE Modernization Project (LAMP) was completed. Corresponding Technical Readiness Levels (TRLs) were also determined for all subsystems using the criteria of DOE G 413.3-4A, Technical Readiness Assessment Guide. The scope of the evaluation was limited to the project Work Breakdown Structure (WBS) elements as defined for the RFQ Injector and Drift Tube Linac (DTL) systems only. Integration of Instrumentation and Controls (I&C) and Safety Systems was not considered, although specific technologies as related to the RFQ and DTL systems were included. Other elements of the project such as Shielding, System Design, Technical Management, and additional facility integration needed to enable off-line testing and pre-installation commissioning were also not evaluated. Each technical subsystem element was evaluated for technical readiness, however, not all were found to meet the criteria for a CTE. Only two subsystem elements were determined to meet the CTE criteria. Their associated TRLs are summarized in the table below. These subsystem elements of the project have the lowest technical readiness due to either being new, novel or modified, requiring additional R&D before being capable of meeting the project Key Performance Parameters (KPPs) and subsystem requirements, or present technology exists but has not yet been demonstrated in a relevant environment. All other subsystems were determined to have a TRL of 8, indicating that actual operating systems exist having similar performance requirements as needed for LAMP. Details of the technical readiness evaluation for each subsystem is given in the following sections of this report.

43 PARTICLE ACCELERATORS↗

An enhanced SOCP-based method for feeder load balancing using the multi-terminal soft open point in active distribution networks

The integration of distributed generators (DGs) exacerbates the feeder power flow fluctuation and load unbalanced condition in active distribution networks (ADNs). The unbalanced feeder load causes inefficient use of network assets and network congestion during system operation. The flexible interconnection based on the multi-terminal soft open point (SOP) significantly benefits the operation of ADNs. The multi-terminal SOP, which is a controllable power electronic device installed to replace the normally open point, provides accurate active and reactive power flow control to enable the flexible connection of feeders. An enhanced SOCP-based method for feeder load balancing using the multi-terminal SOP is proposed in this paper. Furthermore, by regulating the operation of the multi-terminal SOP, the proposed method can mitigate the unbalanced condition of feeder load and simultaneously reduce the power losses of ADNs. Then, the original non-convex model is converted into a second-order cone programming (SOCP) model using convex relaxation. In order to tighten the SOCP relaxation and improve the computation efficiency, an enhanced SOCP-based approach is developed to solve the proposed model. Finally, case studies are performed on the modified IEEE 33-node system to verify the effectiveness and efficiency of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A high power, low temperature molten sodium battery

Low temperature molten sodium batteries promise low-cost, grid-scale energy storage using earth-abundant materials. To be economically viable, they must demonstrate high current (power) at relevant discharge times. Here a low temperature (135 °C) molten sodium battery with a NaI–AlCl 3 molten salt catholyte and NaSICON separator is explored, minimizing cell ohmic resistances and avoiding precipitation reactions in the molten salt catholyte. Operating currents were increased by as much as 100× compared to the energy-dense baseline design (197 Wh kg −1 and 248 mAh cm −2 ). Cells were cycled 100 times at 50 mA cm −2 (150 mW cm −2 ), averaging 99.8% coulombic efficiency and 79.7% energy efficiency for 30% of the theoretical capacity. Charging currents up to 250 mA cm −2 (1070 mW cm −2 ) are demonstrated for 10% of the theoretical capacity. Toward extending the accessible capacity in these high current systems, the volume ratio of catholyte molten salt to a graphite felt current collector was varied, altering (1) the local current density in the graphite felt and (2) the discharge time at a fixed current density. Optimizing the catholyte : felt ratio dramatically increased capacity utilization to 60% (102 mAh cm −2 ) at 50 mA cm −2 (150 mW cm −2 ) charge and 10 mA cm −2 discharge. This catholyte : felt ratio of 1.4 significantly decreased the cell impedance, minimizing electrode blocking effects seen previously in NaI–AlCl 3 catholytes. Together, these high areal loadings and impressive power outputs demonstrate how low temperature molten sodium batteries can compete with commercialized sodium systems operating at more than twice the temperature.

NaSICON↗

Displacement operator for quantum systems with position-dependent mass

A translation operator is introduced to describe the quantum dynamics of a position-dependent mass particle in a null or constant potential. From this operator, we obtain a generalized form of the momentum operator as well as a unique commutation relation for x and p{sub {gamma}}. Such a formalism naturally leads to a Schroedinger-like equation that is reminiscent of wave equations typically used to model electrons with position-dependent (effective) masses propagating through abrupt interfaces in semiconductor heterostructures. The distinctive features of our approach are demonstrated through analytical solutions calculated for particles under null and constant potentials like infinite wells in one and two dimensions and potential barriers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of the WECC WAMS in Wide Area Probing Tests for Validation of System Performance & Modeling

During 2005 and 2006 the Western Electricity Coordinating Council (WECC) performed three major tests of western system dynamics. These tests used a Wide Area Measurement System (WAMS) based primarily on Phasor Measurement Units (PMUs) to determine response to events including the insertion of the 1400-MW Chief Joseph braking resistor, probing signals, and ambient events. Test security was reinforced through real-time analysis of wide area effects, and high-quality data provided dynamic profiles for interarea modes across the entire western interconnection. The tests established that low-level optimized pseudo-random ±20-MW probing with the Pacific DC Intertie (PDCI) roughly doubles the apparent noise that is natural to the power system, providing sharp dynamic information with negligible interference to system operations. Such probing is an effective alternative to use of the 1400-MW Chief Joseph dynamic brake, and it is under consideration as a standard means for assessing dynamic security.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fast high-temperature superconductor switch for high current applications

Reversible operation of a high current superconductor switch based on the quench of high-resistance second generation high temperature superconducting wire is demonstrated. The quench is induced by a burst of an ac field generated by an inductively coupled radio-frequency coil. The switch makes a superconducting-to-normal transition within 5 ms and also has a rapid recovery to the superconducting state. The device has potential applications as an active current limiter or as a storage switch for superconducting magnetic energy storage systems. Operation in a full flux penetration/flow regime can effectively minimize the detrimental effects of the intrinsic conductor non-uniformity. (C) 2013 AIP Publishing LLC.

Solovyov, VF↗

Investigating an API for resilient exascale computing.

Increased HPC capability comes with increased complexity, part counts, and fault occurrences. In- creasing the resilience of systems and applications to faults is a critical requirement facing the viability of exascale systems, as the overhead of traditional checkpoint/restart is projected to outweigh its bene ts due to fault rates outpacing I/O bandwidths. As faults occur and propagate throughout hardware and software layers, pervasive noti cation and handling mechanisms are necessary. This report describes an initial investigation of fault types and programming interfaces to mitigate them. Proof-of-concept APIs are presented for the frequent and important cases of memory errors and node failures, and a strategy proposed for lesystem failures. These involve changes to the operating system, runtime, I/O library, and application layers. While a single API for fault handling among hardware and OS and application system-wide remains elusive, the e ort increased our understanding of both the mountainous challenges and the promising trailheads. 3

Stearley, Jon R.↗

Western Wind and Solar Integration Study Phase 3 – Frequency Response and Transient Stability

Power system operators and utilities worldwide have concerns about the impact of high-penetration wind and solar generation on electric grid reliability (EirGrid 2011b, Hydro-Quebec 2006, ERCOT 2010). The stability of North American grids under these conditions is a particular concern and possible impediment to reaching future renewable energy goals. Phase 3 of the Western Wind and Solar Integration Study (WWSIS-3) considers a 33% wind and solar annual energy penetration level that results in substantial changes to the characteristics of the bulk power system, including different power flow patterns, different commitment and dispatch of existing synchronous generation, and different dynamic behavior of wind and solar generation. WWSIS-3 evaluates two specific aspects of fundamental frequency system stability: frequency response and transient stability.

14 SOLAR ENERGY↗

Design and Development of a High Fidelity Cyber-Physical Testbed

In order to ensure that future critical infrastructure systems are resilient to various types of such advanced and persistent threats, it is important to develop and integrate tailored solutions that holistically address cyber-attack detection and mitigation in a timely manner such that adverse system impacts that impact a large population are avoided. Further, it is essential to create environments that allow control, protection and communication to exist within a realistic environment to analyze the effects of adverse conditions and system operating modes. This project aims to establish a high-fidelity testbed environment for modeling and simulating a single microgrid all the way up to a network of microgrids along with baseline controls, protection, and associated cyber communication. This is an important activity because accurately modeling and simulating the various power-electronics-based DERs and loads in a microgrid is critical to adequately capturing their behaviors over a wide range of off-normal conditions, as well as to evaluate the resilience of the system using the developed controls. The work presented in this report focuses on the process of building this high-fidelity testbed and the associated experimentation it enables. The model enables the creation of high-fidelity use cases and associated datasets that have been used extensively within the initiative to study resilience and support novel control development and prototyping. The work heavily leverages existing capability that is part of the high-fidelity cyber-physical system experimentation lab to create a power hardware-in-the-loop setup. The report also details the creation of an automated model building platform that can enable high-fidelity real-time models to be built without much effort allowing existing low-fidelity models to be analyzed in higher fidelity. Lastly, the report also discusses efforts center around scaling to large complex power system models to make the experimentation more effective.

97 MATHEMATICS AND COMPUTING↗

Evaluating the Shared Root File System Approach for Diskless High-Performance Computing Systems

Diskless high-performance computing (HPC) systems utilizing networked storage have become popular in the last several years. Removing disk drives significantly increases compute node reliability as they are known to be a major source of failures. Furthermore, networked storage solutions utilizing parallel I/O and replication are able to provide increased scalability and availability. Reducing a compute node to processor(s), memory and network interface(s) greatly reduces its physical size, which in turn allows for large-scale dense HPC solutions. However, one major obstacle is the requirement by certain operating systems (OSs), such as Linux, for a root file system. While one solution is to remove this requirement from the OS, another is to share the root file system over the networked storage. This paper evaluates three networked file system solutions, NFSv4, Lustre and PVFS2, with respect to their performance, scalability, and availability features for servicing a common root file system in a diskless HPC configuration. Our findings indicate that Lustre is a viable solution as it meets both, scaling and performance requirements. However, certain availability issues regarding single points of failure and control need to be considered.

97 MATHEMATICS AND COMPUTING↗

A Statistics-Based Threshold for the RMS-Energy Oscillation Detector

System operators and reliability coordinators currently rely on extensive baselining studies to set thresholds for their oscillation detectors. The resulting thresholds are based largely on engineering judgment and may vary significantly between organizations. In this paper, statistical distribution theory is used to derive a detection threshold for the widely deployed root-mean-square (RMS)-energy detector. This expression provides a theoretical basis for the detector's configuration, simplifies the process of selecting the threshold, and enables improved consistency among organizations that need to coordinate during system-wide events. Three methods for calculating the threshold using synchrophasor measurements are also proposed. These methods ensure that the threshold can be calculated reliably for various applications. Tests with simulated and field-measured data demonstrate that the statistics-based threshold provides consistent detection of grid disturbances while maintaining a low probability of false alarm.

Follum, James D.↗

Fast Frequency Response using Reinforcement Learning-Controlled Wind Turbines

To fulfill the auxiliary grid services such as load regulation, spin and non-spin reserve, and frequency support during emergencies, power system operators often require certain wind farms to operate in de-loaded modes. By leveraging the fast response capability of wind farms, the reserved power in deloaded modes can significantly enhance the stability and reliability of power grids. This paper presents a novel methodology that incorporates wind turbines into reinforcement learning-based solutions for frequency response. The proposed approach employs the state-of-the-art reinforcement learning algorithm, surrogategradient- based evolution strategy (GSES), for continuous control of the wind farm output. Our methodology is tested on a modified IEEE-39 bus system, and simulation outcomes demonstrate that the proposed approach can reliably support the frequency of the power system and prevent unnecessary load shedding.

Gao, Wei↗

Photovoltaic and Energy Efficiency Systems Installation (Final Technical Report)

Hackensack University Medical Center's major initiative to create a cleaner healthier and safer environment for patients, employees and the community served by the medical center is built on its commitment to protect the environment and conserve precious energy resources. Since 2004 the Medical Center launched a long term campaign to temper the negative environmental impact of proposed and existing new construction at the medical center and to improve campus wide overall energy efficiency. The plan was to begin by implementing a number of innovative and eco-friendly enhancements to the Gabrellian Women's and Children's Pavilion, in construction at the time, which would lead to Certification by the US Green Building Councils Leadership & Environmental Design (LEED) program. In addition the medical center would evaluate the feasibility of implementing a photovoltaic system in the new construction (in development and planned) to provide clean pollution free electricity. The steps taken to achieve this included conducting a feasibility study complete with architectural and engineering assessments to determine the potential for implementation of a photovoltaic system on the campus and also to conduct an energy survey that would focus on determining specific opportunities and upgrades that would lead to a healthier energy efficient interior environment at the medical center. The studies conducted by the medical center to determine the viability of installing a photovoltaic system identified two key issues that factored into leaderships decision not to implement the solar powered system. These factors were related to the advanced phase of construction of the women's and children's pavilion and the financial considerations to redesign and implement in the ambulatory cancer center. The medical center, in spite of their inability to proceed with the solar aspect of the project upheld their commitment to create a healthier environment for the patients and the community. To achieve a healthier energy efficient interior environment the medical center made substantive upgrades and improvements to the HVAC, plumbing electrical and other operating systems. Measures that were implemented range from use of lighting and plumbing fixture sensors , to reduce electrical and water usage, to use of refrigerants containing hydrochlorofluorocarbons (HCFCs) which cause significantly less depletion of the ozone layer than the refrigerants more commonly used. Additional appropriate energy efficiency component upgrades include the installation of Chiller plants with variable frequency drives (VFDs) and harmonic filters, high efficiency motors, solar window glazing, and lighting/motion sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic and Energy Efficiency Systems Installation

Hackensack University Medical Center's major initiative to create a cleaner healthier and safer environment for patients, employees and the community served by the medical center is built on its commitment to protect the environment and conserve precious energy resources. Since 2004 the Medical Center launched a long term campaign to temper the negative environmental impact of proposed and existing new construction at the medical center and to improve campus wide overall energy efficiency. The plan was to begin by implementing a number of innovative and eco-friendly enhancements to the Gabrellian Women's and Children's Pavilion, in construction at the time, which would lead to Certification by the US Green Building Councils Leadership & Environmental Design (LEED) program. In addition the medical center would evaluate the feasibility of implementing a photovoltaic system in the new construction (in development and planned) to provide clean pollution free electricity. The steps taken to achieve this included conducting a feasibility study complete with architectural and engineering assessments to determine the potential for implementation of a photovoltaic system on the campus and also to conduct an energy survey that would focus on determining specific opportunities and upgrades that would lead to a healthier energy efficient interior environment at the medical center. The studies conducted by the medical center to determine the viability of installing a photovoltaic system identified two key issues that factored into leaderships decision not to implement the solar powered system. These factors were related to the advanced phase of construction of the women's and children's pavilion and the financial considerations to redesign and implement in the ambulatory cancer center. The medical center, in spite of their inability to proceed with the solar aspect of the project upheld their commitment to create a healthier environment for the patients and the community. To achieve a healthier energy efficient interior environment the medical center made substantive upgrades and improvements to the HVAC, plumbing electrical and other operating systems. Measures that were implemented range from use of lighting and plumbing fixture sensors, to reduce electrical and water usage, to use of refrigerants containing hydrochlorofluorocarbons (HCFCs) which cause significantly less depletion of the ozone layer than the refrigerants more commonly used. Additional appropriate energy efficiency component upgrades include the installation of Chiller plants with variable frequency drives (VFDs) and harmonic filters, high efficiency motors, solar window glazing, and lighting/motion sensors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Security Constrained Distributed Transaction Model for Multiple Prosumers

Massive access of renewable energy has prompted demand-side distributed resources to participate in regulation and improve flexibility of power systems. With large-scale access of massive, decentralized, and diverse distributed resources, demand-side market members have transformed from traditional “consumers” to “prosumers”. To explore the distributed transaction model of prosumers, in this paper, a multi-prosumer distributed transaction model is proposed, and the Conditional Value-at-Risk (CVaR) theory is applied to quantify potential risks caused by the stochastic characteristics inherited from renewable energy. First, a prosumer model under constraints of the distribution network including photovoltaic units, fuel cells, energy storage system, central air conditioning and flexible loads is established, and a multi-prosumer distributed transaction strategy is proposed to achieve power sharing among multiple prosumers. Second, a prosumer transaction model based on CVaR is constructed to measure risks inherited from the uncertainty of PV output within the prosumer and ensure safety of system operation in extreme PV output scenarios. Then, the alternating direction multiplier method (ADMM) is utilized to solve the constructed model efficiently. Finally, distributed transaction costs of prosumers are distributed fairly based on the generalized Nash equilibrium to maximize social benefits. Simulation results show the multi-prosumer distributed transaction mechanism established under the proposed generalized Nash equilibrium method can encourage power sharing among prosumers, increasing their own income and social benefits. Also, the CVaR can assist decision making of prosumers in weighting the risks and benefits, improving system resilience through energy management of prosumers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Real-Time Distributed Control of Smart Inverters for Network-level Optimization

The limitations of centralized optimization methods in managing electric power distribution systems operations have led to the distributed paradigm of computing and decision-making. Unfortunately, the existing distributed optimization algorithms are limited in their applicability to managing fast varying phenomena such as those resulting from highly variable Distributed Energy Resource (DER) generation patterns. They require a large number of communication rounds (in the order of 10 2 to 10 3 ) among the computing agents to solve one instance of the optimization problem. Related real-time distributed control methods are equally limited in their applications to power distribution systems with fast-changing DER generation; they require hundreds of rounds of communication and thus are slow in tracking the network-level optimal solutions. In this paper, we propose a novel distributed voltage controller that provides a fast-tracking of rapidly varying DER generation profiles while simultaneously converging to network-level optimal solutions within a few communication rounds. The proposed control algorithm leverages the radial topology of the system, which reduces the required communication rounds to reach the network-level optimum solution by order of magnitude. The novelty lies in carefully reducing the electrical network model from the perspective of each distributed controller and enabling appropriate data sharing among upstream and downstream nodes to achieve fast convergence. The simulation results demonstrate the effectiveness of the proposed approach in minimizing the feeder losses while maintaining the node voltage within the pre-specified limits.

voltage control, optimization, reactive power, inv↗