Search NASA⌕ Search

SEARCH · Search NASA

Results for “PROFILED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

A real-time intercepting beam-profile monitor for a medical cyclotron

There is a lack of real-time continuous beam-diagnostic tools for medical cyclotrons due to high power deposition during proton irradiation. To overcome this limitation, we have developed a profile monitor that is capable of providing continuous feedback about beam shape and current in real time while it is inserted in the beam path. This enables users to optimize the beam profile and observe fluctuations in the beam over time with periodic insertion of the monitor.

43 PARTICLE ACCELERATORS↗

A simple algorithm for beam profile diagnostics using a thermographic camera

A new algorithm for digital image processing apparatuses is developed to evaluate profiles of high-intensity DC beams from temperature images of irradiated thin foils. Numerical analyses are performed to examine the reliability of the algorithm. To simulate the temperature images acquired by a thermographic camera, temperature distributions are numerically calculated for 20 MeV proton beams with different parameters. Noise in the temperature images which is added by the camera sensor is also simulated to account for its effect. Using the algorithm, beam profiles are evaluated from the simulated temperature images and compared with exact solutions. We find that niobium is an appropriate material for the thin foil used in the diagnostic system. We also confirm that the algorithm is adaptable over a wide beam current range of 0.11–214 μA, even when employing a general-purpose thermographic camera with rather high noise (ΔT{sub NETD} ≃ 0.3 K; NETD: noise equivalent temperature difference)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A non-invasive beam profile monitor for charged particle beams

Non-interceptive beam profile monitors are highly desirable in almost all particle accelerators. Such techniques are especially valuable in applications where real time monitoring of the beam properties is required while beam preservation and minimal influence on the vacuum are of the greatest importance. This applies to many kinds of accelerators such as high energy machines where the normal diagnostics cannot withstand the beam's power, medical machines where treatment time is valuable and cannot be allocated to diagnostics and also low energy, low intensity accelerators where the beam's properties are difficult to measure. This paper presents the design of a gas-jet based beam profile monitor which was developed and commissioned at the Cockcroft Institute and can operate in a very large background pressure range from 10{sup −7} down to below 10{sup −11} millibars. The functioning principle of the monitor is described and the first experimental results obtained using a 5 keV electron beam are discussed.

43 PARTICLE ACCELERATORS↗

Preliminary results concerning the simulation of beam profiles from extracted ion current distributions for mini-STRIKE

The Radio Frequency (RF) negative hydrogen ion source prototype has been chosen for the ITER neutral beam injectors due to its optimal performances and easier maintenance demonstrated at Max-Planck-Institut für Plasmaphysik, Garching in hydrogen and deuterium. One of the key information to better understand the operating behavior of the RF ion sources is the extracted negative ion current density distribution. This distribution—influenced by several factors like source geometry, particle drifts inside the source, cesium distribution, and layout of cesium ovens—is not straightforward to be evaluated. The main outcome of the present contribution is the development of a minimization method to estimate the extracted current distribution using the footprint of the beam recorded with mini-STRIKE (Short-Time Retractable Instrumented Kalorimeter). To accomplish this, a series of four computational models have been set up, where the output of a model is the input of the following one. These models compute the optics of the ion beam, evaluate the distribution of the heat deposited on the mini-STRIKE diagnostic calorimeter, and finally give an estimate of the temperature distribution on the back of mini-STRIKE. Several iterations with different extracted current profiles are necessary to give an estimate of the profile most compatible with the experimental data. A first test of the application of the method to the BAvarian Test Machine for Negative ions beam is given.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New x-ray pink-beam profile monitor system for the SPring-8 beamline front-end

A new beam profile monitoring system for the small X-ray beam exiting from the SPring-8 front-end was developed and tested at BL13XU. This system is intended as a screen monitor and also as a position monitor even at beam currents of 100 mA by using photoluminescence of a chemical vapor deposition-grown diamond film. To cope with the challenge that the spatial distribution of the photoluminescence in the vertical direction is too flat to detect the beam centroid within a limited narrow aperture, a filter was installed that absorbs the fundamental harmonic concentrated in the beam center, which resulted in “de-flattening” of the vertical distribution. For the measurement, the filter crossed the photon beam vertically at high speed to withstand the intense heat flux of the undulator pink-beam. A transient thermal analysis, which can simulate the movement of the irradiation position with time, was conducted to determine the appropriate configuration and the required moving speed of the filter to avoid accidental melting. In a demonstration experiment, the vertically separated beam profile could be successfully observed for a 0.8 × 0.8 mm{sup 2} beam shaped by an XY slit and with a fundamental energy of 18.48 keV. The vertical beam centroid could be detected with a resolution of less than 0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An online, energy-resolving beam profile detector for laser-driven proton beams

In this paper, a scintillator-based online beam profile detector for the characterization of laser-driven proton beams is presented. Using a pixelated matrix with varying absorber thicknesses, the proton beam is spatially resolved in two dimensions and simultaneously energy-resolved. A thin plastic scintillator placed behind the absorber and read out by a CCD camera is used as the active detector material. The spatial detector resolution reaches down to ∼4 mm and the detector can resolve proton beam profiles for up to 9 proton threshold energies. With these detector design parameters, the spatial characteristics of the proton distribution and its cut-off energy can be analyzed online and on-shot under vacuum conditions. The paper discusses the detector design, its characterization and calibration at a conventional proton source, as well as the first detector application at a laser-driven proton source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A profile monitor for proton radiography experiments at the Los Alamos Neutron Science Center

The Proton Radiography (pRad) facility at the Los Alamos Neutron Science Center utilizes pulses of protons delivered by the 800 MeV linear accelerator to produce a series of radiographic images to study the dynamic behavior of materials under extreme conditions. Radiographs taken with an empty field of view, or beam pictures, are used to normalize transmission. However, because the center of the proton beam shifts between pulses, an in situ method for measuring beam position is required to normalize images for beam movement to perform absolute radiography. The beam profile monitor described here uses an array of scintillating fibers positioned in the beam path to produce light proportional to beam intensity across the beam cross section. This light is detected using fast photodiodes and a digital oscilloscope, providing a response time of several nanoseconds—suitable for measuring the 50-ns proton pulses used in pRad. The profile monitor achieves a measured position precision of 40 μm and an intensity precision of 0.7%, allowing for beam movement corrections to be applied to images, thereby improving data accuracy and image quality.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of a spatial laser-beam profile in a channel of high-power neodymium facilities

A system for one-dimensional spatial profiling of a laser beam is suggested, capable of compensating for the spatial laserbeam distortions that arise due to a nonuniform gain distribution over the aperture in the amplifying channel of high-power Nd:glass lasers with wide-aperture stages on disk active elements. The principle of operation, the approach to calculation of the key element parameters, and calculation and experimental results of studying the formation of spatial profiles of the laser beam intensity at the output from the system in question are described. Possible applications of the system both in single-beam and multi-beam optical schemes are considered. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial Profile and Beam Composition Measurements of the University of Wisconsin Inertial Electrostatic Confinement Laboratory Ion Guns

A custom designed and manufactured set of ion guns has been in use at the University of Wisconsin Inertial Electrostatic Confinement Laboratory for both beam fusion experiments and materials implantation experiments. For the first time, direct measurements have been made on the spatial profiles and the mass compositions of He and D ion beams produced by these guns. The results validate assumptions about the circular Gaussian spatial profiles for both He and D ion beams. Mass composition measurements of the He beam identified a pressure-dependent minimum impurity content of 15% N + . The D beam contained relative molecular ion fractions of 58% D 3 + , 32% D 2 + , and 10% D + with impurities of 15% to 20% D 2 O + . Finally, a new experimental platform, the Ion Beam and Source Analyzer was developed to perform these experiments on the ion guns used to irradiate candidate fusion materials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Field validation of an actuated convergent-beam acoustic Doppler profiler for high resolution flow mapping

Abstract Energetic river and tidal flow environments feature complex hydrodynamic conditions. Conventional acoustic Doppler profiling instrumentation typically requires assumptions of flow homogeneity over the spatial scales of the divergent beam separation. This removes the ability to measure spatio-temporal variability within the flow. However, velocity variability within these spatial scales is often important in the design of structures and devices exposed to such flow, informing dynamic and peak hydrodynamic load predictions. The research presented outlines the development and testing of a flow measurement instrument consisting of multiple spatially-separated single beam acoustic Doppler profilers converging on a remote focal point, the location of which can be programmatically adjusted through actuation. This increases the spatial resolution at which remote field measurements can be made in energetic flow environments. Field testing of the instrument was conducted in a tidal channel at Sequim Bay Inlet, WA, USA. Results are compared with independent reference measurements made by a co-located, motion-corrected acoustic Doppler velocimeter. This comparison, across tidal velocities of 0.4–0.7 m s −1 , showed a mean velocity error of 0.5%–13.2% across nine sample locations within a 3.00 m × 2.25 m plane. To the authors’ knowledge, this is the first publication of flow velocity results from non-intrusive acoustic measurements at an off-axis, focal point location that features 3D positional control.

13 HYDRO ENERGY↗

Theoretical analysis of key factors achieving reversed magnetic shear q -profiles sustained with lower hybrid waves on EAST

The phase space analysis technique is applied to provide new insights into the fully non-inductive lower hybrid current driven (LHCD) discharges on EAST. The analysis shows that there are bounded and unbounded topologies of lower hybrid (LH) waves in phase space. For typical parameters on EAST, the propagation domain for 4.6 GHz LH waves is bounded, while unbounded for 2.45 GHz LH waves and one of the conditions is recognized to be good for achieving an off-axis current profile driven by 4.6 GHz LH waves on EAST. The parametric analysis on the potential power deposition (PPD) region for those experiments demonstrates that the reversed magnetic shear dominates the wave behavior, and confines the LH power absorption to the far off-axis region as long as it occurs in the 4.6 GHz dominated LHCD discharge. GENRAY/CQL3D simulations also confirm this effect of reversed shear on the power absorption of 4.6 GHz waves. A bounded propagation domain and a positive feedback loop between magnetic shear reversal and off-axis LHCD profile could explain the LH-only-sustained strong reversed magnetic shear observed in experiments on multiple machines. In contrast, there is no such effect for 2.45 GHz waves on EAST since the PPD region is less sensitive to the change of reversed shear due to the unbounded propagation domain.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial profile of argon (1s 5 ) metastables in an electron beam generated plasma

Electron beams with an applied magnetic field generate a secondary cold plasma with a selective chemical composition, featuring low-energy ions and metastable species in the discharge periphery, ideal for low-damage plasma treatment of material substrates. In this work, we studied the plasma generated by an e-beam using a 4 kV voltage in a pure argon gas environment under a magnetic field of 150 G and in the pressure range of 25–90 mTorr. We measured the absolute spatial density profile of argon (1 s 5 ) metastables in an electron beam generated plasma by laser-induced fluorescence and found it to be of the order of 10 16 m −3 . The electron temperature and the electron density measured by a Langmuir probe were of the order of 10 16 m −3 and less than an eV respectively. Electron-impact quenching was identified as a significant loss mechanism for the Ar(1s 5 ) state, leading to the saturation of the metastable density at higher pressures. Outside the primary ionization region, the spatial distribution of argon metastables followed a linear diffusion profile, indicating negligible additional production in those regions.

EEDF↗

An efficient technique for magnetic equilibrium reconstruction with q profile constraints and its application on the EAST tokamak

An efficient technique for building plasma equilibria with preset or constrained q profiles by solving the nonlinear Grad–Shafranov equation iteratively is proposed. Here, the technique uses a set of dynamic virtual poloidal field probes in the plasma core region. Numerical examples are shown for monotonic q profiles and negative central magnetic shear equilibria which are obtained with this technique. As a proof of principle, the technique is applied on the EAST tokamak, to constrain the plasma equilibrium reconstruction with the experimental q = 1 surface information from the ECE diagnostic in addition to the external magnetic measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Aviation Mission Profile Performance Evaluation in a High Specific Power Surface Permanent Magnet Machine with Additively Manufactured Coils and Integrated Heat Pipes

The purpose of this paper is to accurately evaluate the performance and overall efficiency of an electrical machine driving a propeller (as a part of a hybrid or electric propulsion system) during the flight mission profile using electromagnetic-thermal simulations. The study focuses on a 250 kW, 5000 rpm, 1.25 kHz, 36/30 slot/pole surface permanent magnet (SPM) machine with additively manufactured (AM) hollow conductors and integrated heat pipes (HP). The machine drive parameters (frequency, and current) are tuned to maximize the efficiency for a given flight cycle, while providing the highest specific power (SP) during takeoff. Afterward using Multiphysics simulations, the transient thermal behavior of the machine is studied and temperature profile for different parts of the machine is extracted. Finally, steady-state temperatures during cruising are estimated and overall efficiency is re-evaluated.

additive manufacturing↗

Time and Frequency Analysis of Load Profile Data

Technology advancements and integration of modern advanced metering systems can monitor, forecast, inform, control, and operate the building's mechanical, electrical, and plumbing (MEP) systems. They offer a higher level of information, which can contribute to making smart buildings more energy efficient and to making them closer to becoming grid-interactive energy efficient buildings (GEB). This paper builds on the ongoing research on variability analysis of a case study building with a 1-minute load profile and examines the Discrete Wavelet Transform (DWT) process in the frequency domain to quantify the signal's energy in each bandwidth, with respect to each end-use category. Moreover, the amount of variability in the total variability is not similar among the end-use categories. This information is needed to understand the behavior of the variability in the frequency domain for future applications, such as generating synthetic load profiles with a similar frequency spectrum as the measured signal.

decomposition↗

Examination of Humidity and Ice Supersaturation Profiles Over West Antarctica Using Ground-Based G-Band Radiometer Retrievals

Humidity profiles retrieved from a ground-based millimeter-wave radiometer located at McMurdo Station, Antarctica and the West Antarctica Ice Sheet Divide are presented and their suitability to study the humidity of the polar climate is assessed. The dry conditions of the Antarctic winter and spring are ideal for ground-based millimeter-wave measurements and the retrievals appear to realistically reproduce the spatial and temporal variability of humidity at both sites. Furthermore, the radiometer has the ability to capture daily variability of very low humidity (0.5 to 4 g/kg) in the low-to-mid troposphere with an uncertainty of 10-20% during the Antarctic winter, spring, and summer. Despite the coarse vertical resolution (200-600 m in the first 4 km), the retrievals provide additional information with respect to the European Centre for Medium Range Weather Forecasts (ECMWF) profiles used as background information. The radiometer is also able to realistically identify the location and frequency of supersaturated layers with respect to ice in the mid troposphere. The occurrence of supersaturated layers is correlated with the occurrence of ice clouds identified by a cloud mask. Overall, results show that ground-based microwave and millimeter-wave radiometry is a viable complement to satellite observations to provide continuous information on the thermodynamic state of the low-to-mid troposphere at high latitudes.

54 ENVIRONMENTAL SCIENCES↗

Optimizing weak lensing mass estimates for cluster profile uncertainty

Weak lensing measurements of cluster masses are necessary for calibrating mass-observable relations (MORs) to investigate the growth of structure and the properties of dark energy. However, the measured cluster shear signal varies at fixed mass M 200m due to inherent ellipticity of background galaxies, intervening structures along the line of sight, and variations in the cluster structure due to scatter in concentrations, asphericity and substructure. We use N-body simulated halos to derive and evaluate a weak lensing circular aperture mass measurement M ap that minimizes the mass estimate variance <(M ap - M 200m ) 2 > in the presence of all these forms of variability. Depending on halo mass and observational conditions, the resulting mass estimator improves on M ap filters optimized for circular NFW-profile clusters in the presence of uncorrelated large scale structure (LSS) about as much as the latter improve on an estimator that only minimizes the influence of shape noise. Optimizing for uncorrelated LSS while ignoring the variation of internal cluster structure puts too much weight on the profile near the cores of halos, and under some circumstances can even be worse than not accounting for LSS at all. As a result, we discuss the impact of variability in cluster structure and correlated structures on the design and performance of weak lensing surveys intended to calibrate cluster MORs.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimal tuning and calibration of bendable mirrors with slope measuring profilers

We describe a technique to optimally tune and calibrate bendable x-ray optics for sub-micron focusing. The focusing is divided between two elliptically cylindrical reflecting elements, a Kirkpatrick-Baez (KB) pair. Each optic is shaped by applying unequal bending couples to each end of a flat mirror. The developed technique allowsoptimal tuning of these systems using surface slope data obtained with a slope measuring instrument, the long trace profiler (LTP). Due to the near linearity of the problem, the minimal set of data necessary for the tuning of each bender, consists of only three slope traces measured before and after a single adjustment of each bending couple. The data are analyzed with software realizing a method of regression analysis with experimentally found characteristic functions of the benders. The resulting approximation to the functional dependence of the desired shape provides nearly final settings. Moreover, the characteristic functions of the benders found in the course of tuning, can be used for retuning to a new desired shape without removal from the beamline and re-measuring. We perform a ray trace, using profiler data for the finally tuned optics, predicting the performance to be expected during use of the optics on the beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗