Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Persistence of chlorfluazuron in cabbage under different agro-climatic conditions of India and its risk assessment

Here, a multilocational field trial was conducted at 4 locations in India—Rajasthan, Gujarat, Madhya Pradesh, and West Bengal—to determine the persistence in cabbage of chlorfluazuron applied twice at 75 and 150 g active ingredient ha -1 . Cabbage head samples were collected from each replicated plot on 0 (2 h after spraying), 1, 3, 5, 7, 10, and 15 d after final insecticide application, including an untreated control. Chlorfluazuron residue in cabbage and field soil was estimated by high-performance liquid chromatography using a photo diode array detector. The limit of determination and limit of quantification of the method were recorded as 0.05 and 0.10 μg g -1 , respectively. Results revealed that chlorfluazuron dissipated linearly with progress of time, following first-order kinetics. The mean (± standard deviation) half-life value of chlorfluazuron in cabbage was found to be 7.18 ± 0.71 d, considering different locations and treatments. The residue was below the level of quantification in the harvested cabbage and soil samples. Harvesting cabbage in the experimental location, at least on day 7, after 2 applications of chlorfluazuron at the recommended dose, may not pose any ill effect for Indian adults.

59 BASIC BIOLOGICAL SCIENCES↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Magnitude of Interfractional Vaginal Cuff Movement: Implications for External Irradiation

Purpose: To quantify the extent of interfractional vaginal cuff movement in patients receiving postoperative irradiation for cervical or endometrial cancer in the absence of bowel/bladder instruction. Methods and Materials: Eleven consecutive patients with cervical or endometrial cancer underwent placement of three gold seed fiducial markers in the vaginal cuff apex as part of standard of care before simulation. Patients subsequently underwent external irradiation and brachytherapy treatment based on institutional guidelines. Daily megavoltage CT imaging was performed during each external radiation treatment fraction. The daily positions of the vaginal apex fiducial markers were subsequently compared with the original position of the fiducial markers on the simulation CT. Composite dose-volume histograms were also created by summing daily target positions. Results: The average ({+-} standard deviation) vaginal cuff movement throughout daily pelvic external radiotherapy when referenced to the simulation position was 16.2 {+-} 8.3 mm. The maximum vaginal cuff movement for any patient during treatment was 34.5 mm. In the axial plane the mean vaginal cuff movement was 12.9 {+-} 6.7 mm. The maximum vaginal cuff axial movement was 30.7 mm. In the craniocaudal axis the mean movement was 10.3 {+-} 7.6 mm, with a maximum movement of 27.0 mm. Probability of cuff excursion outside of the clinical target volume steadily dropped as margin size increased (53%, 26%, 4.2%, and 1.4% for 1.0, 1.5, 2.0, and 2.5 cm, respectively.) However, rectal and bladder doses steadily increased with larger margin sizes. Conclusions: The magnitude of vaginal cuff movement is highly patient specific and can impact target coverage in patients without bowel/bladder instructions at simulation. The use of vaginal cuff fiducials can help identify patients at risk for target volume excursion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Statistical Assessment of Proton Treatment Plans Under Setup and Range Uncertainties

Purpose: To evaluate a method for quantifying the effect of setup errors and range uncertainties on dose distribution and dose–volume histogram using statistical parameters; and to assess existing planning practice in selected treatment sites under setup and range uncertainties. Methods and Materials: Twenty passively scattered proton lung cancer plans, 10 prostate, and 1 brain cancer scanning-beam proton plan(s) were analyzed. To account for the dose under uncertainties, we performed a comprehensive simulation in which the dose was recalculated 600 times per given plan under the influence of random and systematic setup errors and proton range errors. On the basis of simulation results, we determined the probability of dose variations and calculated the expected values and standard deviations of dose–volume histograms. The uncertainties in dose were spatially visualized on the planning CT as a probability map of failure to target coverage or overdose of critical structures. Results: The expected value of target coverage under the uncertainties was consistently lower than that of the nominal value determined from the clinical target volume coverage without setup error or range uncertainty, with a mean difference of −1.1% (−0.9% for breath-hold), −0.3%, and −2.2% for lung, prostate, and a brain cases, respectively. The organs with most sensitive dose under uncertainties were esophagus and spinal cord for lung, rectum for prostate, and brain stem for brain cancer. Conclusions: A clinically feasible robustness plan analysis tool based on direct dose calculation and statistical simulation has been developed. Both the expectation value and standard deviation are useful to evaluate the impact of uncertainties. The existing proton beam planning method used in this institution seems to be adequate in terms of target coverage. However, structures that are small in volume or located near the target area showed greater sensitivity to uncertainties.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Full core LOCA safety analysis for a PWR containing high burnup fuel

For economic reasons, the US nuclear industry is renewing efforts to build a technical basis to extend peak rod average burnup limits above the current regulatory burnup limit of 62 GWd/MTU. The primary driver of these efforts is to economically increase pressurized water reactor (PWR) cycle lengths to 24 months, reduce the number of fresh fuel assemblies, increase time online, thereby reducing number of outages and their associated cost, higher fuel utilization, and possibly reduce core design constraints. In order for US nuclear utilities to leverage these economic efficiencies, the US Nuclear Regulatory Commission (NRC) will likely require nuclear power plants (NPPs) to analyze a number of potential operational occurrences and their potential consequences with each new core design prior to resuming normal operation. Potential operational occurrences can be divided into three primary regimes: (1) normal operation, (2) anticipated operation occurrences (AOOs), and (3) design basis accidents (DBAs). Normal plant operation is an operating regime in which the plant operates within specified operational limits until the end of the cycle, whereas AOOs are events that result in the NPP deviating outside the normal operating regime. A key attribute of an AOO is that the occurrence should be expected. However, by definition, the occurrence of an AOO does not result in significant impact to critical safety functions. The last potential operational occurrence is a DBA. From the fuel performance point-of-view, DBAs can be subdivided into two bounding categories: (1) loss of coolant accidents (LOCAs), and (2) reactivity insertion accidents (RIAs). Unlike AOOs, DBAs may result in fuel rod failure. The NRC imposes fundamental acceptance criteria to minimize radiological consequences to the public and onsite staff. Furthermore, safety criteria are typically linked to the fulfillment of other acceptance criteria related to reactor safety equipment designed to mitigate DBAs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Hygroscopicity of organic compounds as a function of carbon chain length, carboxyl, hydroperoxy, and carbonyl functional groups

The albedo and microphysical properties of clouds are controlled in part by the hygroscopicity of particles serving as cloud condensation nuclei (CCN). Hygroscopicity of complex organic mixtures in the atmosphere varies widely and remains challenging to predict. Here we present new measurements characterizing the CCN activity of pure compounds in which carbon chain length and the number of hydroperoxy, carboxyl, and carbonyl functional groups were systematically varied to establish the contributions of these groups to organic aerosol apparent hygroscopicity. Apparent hygroscopicity decreased with carbon chain length and increased with polar functional groups in the order carboxyl > hydroperoxy > carbonyl. Activation diameters at different supersaturations deviated from the -3/2 slope in log-log space predicted by Köhler theory, suggesting that water solubility limits CCN activity of particles composed of weakly functionalized organic compounds. Results are compared to a functional group contribution model that predicts CCN activity of organic compounds. The model performed well for most compounds but under-predicted the CCN activity of hydroperoxy groups. New best-fit hydroperoxy group/water interaction parameters were derived from the available CCN data. Lastly, these results may help improve estimates of the CCN activity of ambient organic aerosols from composition data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of a spatially resolved ion temperature diagnostic for inertial confinement fusion

Here, the performance of modern laser-driven inertial confinement fusion (ICF) experiments is degraded by contamination of the deuterium–tritium (DT) fuel with high-Z material during compression. Simulations suggest that this mix can be described by the ion temperature distribution of the implosion, given that such contaminants deviate in temperature from the surrounding DT plasma. However, existing neutron time-of-flight (nTOF) diagnostics only measure the spatially integrated ion temperature. This paper describes the techniques and forward modeling used to develop a novel diagnostic imaging system to measure the spatially resolved ion temperature of an ICF implosion for the first time. The technique combines methods in neutron imaging and nTOF diagnostics to measure the ion temperature along one spatial dimension at yields currently achievable on the OMEGA laser. A detailed forward model of the source and imaging system was developed to guide instrument design. The model leverages neutron imaging reconstruction algorithms, radiation hydrodynamics and Monte Carlo simulations, optical ray tracing, and more. The results of the forward model agree with the data collected on OMEGA using the completed diagnostic. The analysis of the experimental data is still ongoing and will be discussed in a separate publication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AN ELECTRON-TRACKING COMPTON TELESCOPE FOR A SURVEY OF THE DEEP UNIVERSE BY MeV GAMMA-RAYS

Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which originate from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton Camera (CC), detected a mere ∼30 persistent sources. It is in stark contrast with the ∼2000 sources in the GeV band. Here we report the performance of an Electron-Tracking Compton Camera (ETCC), and prove that it has a good potential to break through this stagnation in MeV gamma-ray astronomy. The ETCC provides all the parameters of Compton-scattering by measuring 3D recoil electron tracks; then the Scatter Plane Deviation (SPD) lost in CCs is recovered. The energy loss rate (dE/dx), which CCs cannot measure, is also obtained, and is found to be helpful to reduce the background under conditions similar to those in space. Accordingly, the significance in gamma detection is improved severalfold. On the other hand, SPD is essential to determine the point-spread function (PSF) quantitatively. The SPD resolution is improved close to the theoretical limit for multiple scattering of recoil electrons. With such a well-determined PSF, we demonstrate for the first time that it is possible to provide reliable sensitivity in Compton imaging without utilizing an optimization algorithm. As such, this study highlights the fundamental weak-points of CCs. In contrast we demonstrate the possibility of ETCC reaching the sensitivity below 1 × 10{sup −12} erg cm{sup −2} s{sup −1} at 1 MeV.

79 ASTRONOMY AND ASTROPHYSICS↗

Energetic particle optimization of quasi-axisymmetric stellarator equilibria

Abstract An important goal of stellarator optimization is to achieve good confinement of energetic particles such as, in the case of a reactor, alphas created by deuterium–tritium fusion. In this work, a fixed-boundary stellarator equilibrium was re-optimized for energetic particle confinement via a two-step process: first, by minimizing deviations from quasi-axisymmetry (QA) on a single flux surface near the mid-radius, and secondly by maintaining this improved QA while minimizing the analytical quantity Γ C , which represents the angle between magnetic flux surfaces and contours of J | | , the second adiabatic invariant. This was performed multiple times, resulting in a group of equilibria with significantly reduced energetic particle losses, as evaluated by Monte Carlo simulations of alpha particles in scaled-up versions of the equilibria. This is the first time that energetic particle losses in a QA stellarator have successfully been reduced by optimizing Γ C . The relationship between energetic particle losses and metrics such as QA error ( E q a ) and Γ C in this set of equilibria were examined via statistical methods and a nearly linear relationship between volume-averaged Γ C and prompt particle losses was found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design and Stability of Load-Side Primary Frequency Control in Power Systems

We present a systematic method to design ubiquitous continuous fast-acting distributed load control for primary frequency regulation in power networks, by formulating an optimal load control (OLC) problem where the objective is to minimize the aggregate cost of tracking an operating point subject to power balance over the network. We prove that the swing dynamics and the branch power flows, coupled with frequency-based load control, serve as a distributed primal-dual algorithm to solve OLC. We establish the global asymptotic stability of a multimachine network under such type of load-side primary frequency control. These results imply that the local frequency deviations on each bus convey exactly the right information about the global power imbalance for the loads to make individual decisions that turn out to be globally optimal. Simulations confirm that the proposed algorithm can rebalance power and resynchronize bus frequencies after a disturbance with significantly improved transient performance.

Zhao, CH↗

SU-E-T-133: Dosimetric Impact of Scan Orientation Relative to Target Motion During Spot Scanning Proton Therapy

Purpose: This study seeks to evaluate the dosimetric effects of intra-fraction motion during spot scanning proton beam therapy as a function of beam-scan orientation and target motion amplitude. Method: Multiple 4DCT scans were collected of a dynamic anthropomorphic phantom mimicking respiration amplitudes of 0 (static), 0.5, 1.0, and 1.5 cm. A spot-scanning treatment plan was developed on the maximum intensity projection image set, using an inverse-planning approach. Dynamic phantom motion was continuous throughout treatment plan delivery.The target nodule was designed to accommodate film and thermoluminescent dosimeters (TLD). Film and TLDs were uniquely labeled by location within the target. The phantom was localized on the treatment table using the clinically available orthogonal kV on-board imaging device. Film inserts provided data for dose uniformity; TLDs provided a 3% precision estimate of absolute dose. An inhouse script was developed to modify the delivery order of the beam spots, to orient the scanning direction parallel or perpendicular to target motion.TLD detector characterization and analysis was performed by the Imaging and Radiation Oncology Core group (IROC)-Houston. Film inserts, exhibiting a spatial resolution of 1mm, were analyzed to determine dose homogeneity within the radiation target. Results: Parallel scanning and target motions exhibited reduced target dose heterogeneity, relative to perpendicular scanning orientation. The average percent deviation in absolute dose for the motion deliveries relative to the static delivery was 4.9±1.1% for parallel scanning, and 11.7±3.5% (p<<0.05) for perpendicularly oriented scanning. Individual delivery dose deviations were not necessarily correlated to amplitude of motion for either scan orientation. Conclusions: Results demonstrate a quantifiable difference in dose heterogeneity as a function of scan orientation, more so than target amplitude. Comparison to the analyzed planar dose of a single field hint that multiple-field delivery alters intra-fraction beam-target motion synchronization and may mitigate heterogeneity, though further study is warranted.

60 APPLIED LIFE SCIENCES↗

SU-C-210-04: Considerable Pancreatic Tumor Motion During Breath-Hold Measured Using Intratumoral Fiducials On Fluoroscopic Movies

Purpose: Using a breath hold (BH) technique during radiotherapy of pancreatic tumors is expected to reduce intra-fractional motion. The aim of this study was to evaluate the tumor motion during BH. Methods: In this pilot study, we included 8 consecutive pancreatic cancer patients. All had 2– 4 intratumoral gold fiducials. Patients were asked to perform 3 consecutive 30-second end-inhale BHs on day 5, 10 and 15 of their three-week treatment. During BH, airflow through a mouthpiece was measured using a spirometer. Any inadvertent flow of air during BH was monitored for all patients. We measured tumor motion on lateral fluoroscopic movies (57 in total) made during BH. In each movie the fiducials as a group were tracked over time in superior-inferior (SI) and anterior-posterior (AP) direction using 2-D image correlation between consecutive frames. We determined for each patient the range of intra-BH motion over all movies; we also determined the absolute means and standard deviations (SDs) for the entire patient group. Additionally, we investigated the relation between inadvertent airflow during BH and the intra-BH motion. Results: We found intra-BH tumor motion of up to 12.5 mm (range, 1.0–12.5 mm) in SI direction and up to 8.0 mm (range, 1.0–8.0 mm) in AP direction. The absolute mean motion over the patient population was 4.7 (SD: 3.0) mm and 2.8 (SD: 1.2) mm in the SI and AP direction, respectively. Patients were able to perform stable consecutive BHs; during only 20% of the movies we found very small airflows (≤ 65 ml). These were mostly stepwise in nature and could not explain the continuous tumor motions we observed. Conclusion: We found substantial (up to 12.5 mm) pancreatic tumor motion during BHs. We found minimal inadvertent airflow, seen only during a minority of BHs, and this did not explain the obtained results. This work was supported by the foundation Bergh in het Zadel through the Dutch Cancer Society (KWF Kankerbestrijding) project No. UVA 2011-5271.

60 APPLIED LIFE SCIENCES↗

SU-F-J-74: High Z Geometric Integrity and Beam Hardening Artifact Assessment Using a Retrospective Metal Artifact Reduction (MAR) Reconstruction Algorithm

Purpose: To test the efficacy of a retrospective metal artifact reduction (MAR) reconstruction algorithm for a commercial computed tomography (CT) scanner for radiation therapy purposes. Methods: High Z geometric integrity and artifact reduction analysis was performed with three phantoms using General Electric’s (GE) Discovery CT. The three phantoms included: a Computerized Imaging Reference Systems (CIRS) electron density phantom (Model 062) with a 6.5 mm diameter titanium rod insert, a custom spine phantom using Synthes Spine hardware submerged in water, and a dental phantom with various high Z fillings submerged in water. Each phantom was reconstructed using MAR and compared against the original scan. Furthermore, each scenario was tested using standard and extended Hounsfield Unit (HU) ranges. High Z geometric integrity was performed using the CIRS phantom, while the artifact reduction was performed using all three phantoms. Results: Geometric integrity of the 6.5 mm diameter rod was slightly overestimated for non-MAR scans for both standard and extended HU. With MAR reconstruction, the rod was underestimated for both standard and extended HU. For artifact reduction, the mean and standard deviation was compared in a volume of interest (VOI) in the surrounding material (water and water equivalent material, ∼0HU). Overall, the mean value of the VOI was closer to 0 HU for the MAR reconstruction compared to the non-MAR scan for most phantoms. Additionally, the standard deviations for all phantoms were greatly reduced using MAR reconstruction. Conclusion: GE’s MAR reconstruction algorithm improves image quality with the presence of high Z material with minimal degradation of its geometric integrity. High Z delineation can be carried out with proper contouring techniques. The effects of beam hardening artifacts are greatly reduced with MAR reconstruction. Tissue corrections due to these artifacts can be eliminated for simple high Z geometries and greatly reduced for more complex geometries.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-02: A New Intra-Fractional Prostate Motion Tracking Method in Volumetric Modulated Arc Therapy (VMAT) Via 2D/3D Registration

Purpose: Intra-fractional prostate motion leads uncertainty on delivered dose in radiotherapy and may cause significant dose deviation from the planned dose distribution. This is especially a concern in scenarios with a high dose per fraction and hence a long delivery time, e.g. stereotactic body radiotherapy. Knowledge about intra-fractional prostate motion is valuable to address this problem, e.g. by reconstructing delivered dose and performing adaptation. This study proposes a new approach to determine intra-fractional prostate motion in VMAT via 2D/3D maker registration. Methods: At our institution, each patient has three markers implanted in the prostate. During treatment delivery, kV triggered images were taken every three seconds to acquire 2D projection of 3D anatomy at the direction orthogonal to the therapeutic beam. Projected marker locations were identified on each projection image using template matching with geometric constraints. 3D prostate translation and rotation for each triggered image were obtained by solving an optimization problem, such that the calculated marker locations match the measured ones. Inter-image motion smoothness was employed as a constraint. We tested this method in simulation studies with five realistic prostate motion trajectories acquired via Calypso and in real phantom experiments. Results: For the simulation case, the motion range for these patients was 0.5∼6.0 mm. Root mean square (RMS) error of calculated motion along left-right (LR), anterior-posterior (AP) and cranial-caudal (CC) directions were 0.26mm, 0.36mm, and 0.016mm, respectively. The motion range in the phantom study along LR, AP, and CC directions were 15mm, 20mm and 10mm. The mean RMS errors along these directions were 1.99mm, 1.37mm and 0.22mm. Conclusion: A new prostate motion tracking algorithm based on kV triggered images has been developed and validated. Clinically acceptable accuracy has been achieved.

60 APPLIED LIFE SCIENCES↗

Comparison of Results for Quarter 1 Surface Water Split Samples Collected at the Nuclear Fuel Services Site, Erwin, Tennessee

Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, collected split surface water samples with Nuclear Fuel Services (NFS) representatives on August 22, 2012. Representatives from the U.S. Nuclear Regulatory Commission and Tennessee Department of Environment and Conservation were also in attendance. Samples were collected at four surface water stations, as required in the approved Request for Technical Assistance number 11-018. These stations included Nolichucky River upstream (NRU), Nolichucky River downstream (NRD), Martin Creek upstream (MCU), and Martin Creek downstream (MCD). Both ORAU and NFS performed gross alpha and gross beta analyses. The comparison of results using the duplicate error ratio (DER), also known as the normalized absolute difference. A DER ≤ 3 indicates that, at a 99% confidence interval, split sample results do not differ significantly when compared to their respective one standard deviation (sigma) uncertainty. The NFS split sample report does not specify the confidence level of reported uncertainties. Therefore, standard two sigma reporting is assumed and uncertainty values were divided by 1.96. A comparison of split sample results, using the DER equation, indicates one set with a DER greater than 3. A DER of 3.1 is calculated for gross alpha results from ORAU sample 5198W0003 and NFS sample MCU-310212003. The ORAU result is 0.98 ± 0.30 pCi/L (value ± 2 sigma) compared to the NFS result of -0.08 ± 0.60 pCi/L. Relatively high DER values are not unexpected for low (e.g., background) analyte concentrations analyzed by separate laboratories, as is the case here. It is noted, however, NFS uncertainties are at least twice the ORAU uncertainties, which contributes to the elevated DER value. Differences in ORAU and NFS minimum detectable activities are even more pronounced. comparison of ORAU and NFS split samples produces reasonably consistent results for low (e.g., background) concentrations.

54 ENVIRONMENTAL SCIENCES↗

Assessment of the Revised 3410 Building Filtered Exhaust Stack Sampling Probe Location

In order to support the air emissions permit for the 3410 Building, Pacific Northwest National Laboratory performed a series of tests in the exhaust air discharge from the reconfigured 3410 Building Filtered Exhaust Stack. The objective was to determine whether the location of the air sampling probe for emissions monitoring meets the applicable regulatory criteria governing such effluent monitoring systems. In particular, the capability of the air sampling probe location to meet the acceptance criteria of ANSI/HPS N13.1-2011 , Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities was determined. The qualification criteria for these types of stacks address 1) uniformity of air velocity, 2) sufficiently small flow angle with respect to the axis of the duct, 3) uniformity of tracer gas concentration, and 4) uniformity of tracer particle concentration. Testing was performed to conform to the quality requirements of NQA-1-2000. Fan configurations tested included all fan combinations of any two fans at a time. Most of the tests were conducted at the normal flow rate, while a small subset of tests was performed at a slightly higher flow rate achieved with the laboratory hood sashes fully open. The qualification criteria for an air monitoring probe location are taken from ANSI/HPS N13.1-2011 and are paraphrased as follows with key results summarized: 1. Angular Flow—The average air velocity angle must not deviate from the axis of the stack or duct by more than 20°. Our test results show that the mean angular flow angles at the center two-thirds of the ducts are smaller than 4.5% for all testing conditions. 2. Uniform Air Velocity—The acceptance criterion is that the COV of the air velocity must be ≤ 20% across the center two thirds of the area of the stack. Our results show that the COVs of the air velocity across the center two-thirds of the stack are smaller than 2.9% for all testing conditions. 3. Uniform Concentration of Tracer Gases—The uniformity of the concentration of potential contaminants is first tested using a tracer gas to represent gaseous effluents. The tracer is injected downstream of the fan outlets and at the junction downstream fan discharges meet. The acceptance criteria are that 1) the COV of the measured tracer gas concentration is ≤20% across the center two-thirds of the sampling plane and 2) at no point in the sampling plane does the concentration vary from the mean by >30%. Our test results show that 1) the COV of the measured tracer gas concentration is < 2.9% for all test conditions and 2) at no point in the sampling plane does the concentration vary from the mean by >6.5%. 4. Uniform Concentration of Tracer Particles—Tracer particles of 10-μm aerodynamic diameter are used for the second demonstration of concentration uniformity. The acceptance criterion is that the COV of particle concentration is ≤ 20% across the center two thirds of the sampling plane. Our test results indicate that the COV of particle concentration is <9.9% across the center two-thirds of the sampling plane among all testing conditions. Thus, the reconfigured 3410 Building Filtered Exhaust Stack was determined to meet the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Changes to the system configuration or operations outside the bounds described in this report (e.g., exhaust stack velocity changes, relocation of sampling probe, and addition of fans) may require re-testing or re-evaluation to determine compliance.

3410 building↗

Lakeview, Oregon, Disposal Site

9.1 Compliance Summary The Lakeview, Oregon, Uranium Mill Tailings Radiation Control Act (UMTRCA) Title I Disposal Site was inspected September 16 and 17, 2015. Other than some ongoing concern with erosion-control rock riprap degradation, the disposal cell was in good condition. Some minor fence repairs and vegetation removal, and minor erosion repair work along the west site fence is planned. Inspectors identified no other maintenance needs or cause for a follow-up or contingency inspection. Disposal cell riprap is evaluated annually to ensure continued long-term protection of the cell from erosion during a severe precipitation event. Degradation of the rock riprap was first observed at the site in the mid-1990s. Rock gradation monitoring of the riprap on the west side slope has been performed as part of the annual inspection since 1997 to determine the mean diameter (D 50 ) value. As prescribed by the monitoring procedure, the rock monitoring is routinely conducted at random locations. However, at the U.S. Nuclear Regulatory Commission’s (NRC’s) request, the 2015 rock monitoring approach deviated from the normal procedure by using a pre-established monitoring grid in a subset area of the west side slope. This changed the monitoring approach from random sampling to biased sampling. The D 50 value measured during the 2015 gradation monitoring is 2.39 inches, which falls below the original D 50 design size range of 2.7–3.9 inches for the Type B size side slope riprap. At NRC’s request, rock durability monitoring was added to the gradation monitoring in 2009 to monitor durability by rock type. Results of the 2015 durability monitoring showed that74 percent of the total rock sampled is durability class code A rock with an assigned durability class of “highly durable” or durability class code B “durable” rock, and that over 90 percent of the 3-inch or larger rock is durability class code A or B. The rock durability classifications are further explained in Section 9.4.2.2.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Antifoam Development for Eliminating Flammability Hazards and Decreasing Cycle Time in the Defense Waste Processing Facility

Foam, due to the high gas generation rates of boiling and chemical reaction offgasing, requires control measures to prevent the foam from contaminating the condensate and to facilitate efficient plant operation. Antifoam was utilized to minimize foam production during chemical processing in the DWPF and during High-Level Waste (HLW) evaporation at SRS and Hanford. However, the current antifoam used in the SRS DWPF increases flammability risk during chemical processing (generates three flammable degradation products) and while feeding the melter (can decompose to CO/hydrogen). It is also the likely source of methyl functional groups for the organo-mercury present in the tank farm and excessive mercury in Saltstone. Additionally, the planned startup of Salt Waste Processing Facility (SWPF), with much higher throughput, will challenge DWPF to process at higher gas generation rates. DWPF employs Antifoam 747, a superspreader produced by Momentive Performance Materials, as an antifoaming agent during waste processing. During DWPF chemical processing, antifoam must be effective up to boiling (i.e., up to 103°C) and between a pH of 3-13. Antifoam 747 is most effective at a pH range of 6-8 and degrades as pH deviates. In addition, SRNL identified three flammable antifoam degradation products using mass spectrometer (MS) and fourier transform infrared (FTIR) offgas analyzers during simulations. A new antifoam or a new method to control foam is needed to minimize DWPF processing time and reduce the risk of contamination. In addition, testing should be completed to ensure that other antifoams used in HLW processing do not have similar flammability hazards or cause unintended impacts in downstream processing.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗