Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Proposal for a Non-Interceptive Spatio-Temporal Correlation Monitor

Designs toward TeV-range electron-positron linear colliders include a non-zero crossing angle colliding scheme at the interaction point to mitigate instabilities and possible background. Maximizing the luminosity when operating with non-zero crossing angles requires the use of 'crab' cavities to impart a well-defined spatio-temporal correlation. In this paper we propose a novel noninterceptive diagnostic capable of measuring and monitoring the spatio-temporal correlation, i.e. the transverse position of sub-picosecond time slices, within bunch. An analysis of the proposed scheme, its spatio-temporal resolution and its limitations are quantified. Finally, the design of a proof-of-principle experiment in preparation for the Fermilab's A0 photoinjector is presented.

43 PARTICLE ACCELERATORS↗

Introduction to phasing

This introductory paper to the CCP4 weekend on experimental phasing introduces the concept of the ‘phase problem’ for non-experts. Modern methods of phasing are explored, including some recent examples that can be downloaded as tutorials. When collecting X-ray diffraction data from a crystal, we measure the intensities of the diffracted waves scattered from a series of planes that we can imagine slicing through the crystal in all directions. From these intensities we derive the amplitudes of the scattered waves, but in the experiment we lose the phase information; that is, how we offset these waves when we add them together to reconstruct an image of our molecule. This is generally known as the ‘phase problem’. We can only derive the phases from some knowledge of the molecular structure. In small-molecule crystallography, some basic assumptions about atomicity give rise to relationships between the amplitudes from which phase information can be extracted. In protein crystallography, these ab initio methods can only be used in the rare cases in which there are data to at least 1.2 Å resolution. For the majority of cases in protein crystallography phases are derived either by using the atomic coordinates of a structurally similar protein (molecular replacement) or by finding the positions of heavy atoms that are intrinsic to the protein or that have been added (methods such as MIR, MIRAS, SIR, SIRAS, MAD, SAD or combinations of these). The pioneering work of Perutz, Kendrew, Blow, Crick and others developed the methods of isomorphous replacement: adding electron-dense atoms to the protein without disturbing the protein structure. Nowadays, methods from small-molecule crystallography can be used to find the heavy-atom substructure and the phases for the whole protein can be bootstrapped from this prior knowledge. More recently, improved X-ray sources, detectors and software have led to the routine use of anomalous scattering to obtain phase information from either incorporated selenium or intrinsic sulfurs. In the best cases, only a single set of X-ray data (SAD) is required to provide the positions of the anomalous scatters, which together with density-modification procedures can reveal the structure of the complete protein.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-EF-303-03: A New Aperture-Based Imaging System for Prompt-Gamma Range Verification of Proton Beam Therapy

Purpose: To develop and characterize a novel aperture-based imaging system for high-energy gamma-rays. This collimated system will provide 2-dimensional imaging capability for verification of proton beam range and Bragg peak dose via prompt-gamma detection. Methods: A multi-knife-edge slit collimator has been designed, constructed, and characterized via simulations and experimental measurements. The 20×20×7.5 cm{sup 3} tungsten collimator and accompanying LSO scintillation detector were simulated using the TOPAS Geant4 -based Monte Carlo package. Iterative reconstruction methods were combined with point response functions to characterize the imaging performance of the system. The response of the system has begun to be characterized experimentally as well, using 2.6 MeV gamma-rays from Th-228. Results: Both simulation and experimental results indicate that this collimated system provides 2-D imaging capability in the energy range of interest for prompt-gamma dose verification. In the current configuration, with collimator to source distance of 13 cm, image reconstruction of point sources resulted in spatial resolution (FWHM) of approximately 4 mm in both x-and y-directions in the imaging plane. The accuracy of positioning the point sources is less than 1 mm. Conclusion: This work has characterized, via simulation and measurements, a novel multi-knife-edge slit collimator in front of a more conventional position-sensitive LSO scintillator detector. The multi-slit pattern is designed to increase detection efficiency and provide spatial information in 2-dimensions -- an improvement over a single-slit collimator design. The thickness and density of the collimator will allow this detection system to perform well in an environment with high gamma flux, while ultimately providing peak determination accuracy on the order of 1 mm. This material is based upon work supported by the Department of Energy National Nuclear Security Administration under Award Number: DE-NA0000979 through the Nuclear Science and Security Consortium.

60 APPLIED LIFE SCIENCES↗

The SWIFT Gamma-Ray Burst X-Ray Telescope

The Swift Gamma-Ray Burst Explorer is designed to make prompt multi-wavelength observations of Gamma-Ray Bursts and GRB afterglows. The X-ray Telescope enables Swift to determine GRB positions with a few arcseconds accuracy within 100 seconds of the burst onset. The XRT utilizes a mirror set built for JET-X and an XMM-Newton/ EPIC MOS CCD detector to provide a sensitive broad-band (0.2-10 keV) X-ray imager with an effective area of more than 120 sq cm at 1.5 keV, a field of view of 23.6 x 23.6 arcminutes, and an angular resolution of 18 arcseconds (HPD). The detection sensitivity is 2x10(exp 14) erg/sq cm/s in 10(exp 4) seconds. The instrument provides automated source detection and position reporting within 5 seconds of target acquisition. It can also measure the redshifts of GRBs with Iron line emission or other spectral features. The XRT operates in an auto-exposure mode, adjusting the CCD readout mode automatically to optimize the science return as the source intensity fades. The XRT measures spectra and lightcurves of the GRB afterglow beginning about a minute after the burst and follows each burst for days or weeks. We provide an overview of the X-ray Telescope scientific background from which the systems engineering requirements were derived, with specific emphasis on the design and qualification aspects from conception through to launch. We describe the impact on cleanliness and vacuum requirements for the instrument low energy response and to maintain the high sensitivity to the fading signal of the Gamma-ray Bursts.

Hill, J. E.↗

THE STELLAR KINEMATIC CENTER AND THE TRUE GALACTIC NUCLEUS OF NGC 253

We present the first sub-arcsecond resolution two-dimensional stellar kinematics and X-ray observations of the prototypical starburst galaxy NGC 253 which define the position and nature of the galactic nucleus. These observations comprise some of the best probes of the central 300 pc of NGC 253, the nearest massive galaxy undergoing a powerful starburst, and will allow us to gain more insight into the nature of the centers of starburst galaxies. We get an estimate of the stellar kinematic center location corresponding to an area of r {approx} 1.''2 centered {approx}0.''7 southwest (SW) from the radio core, and historically presumed nucleus, TH2. Newly processed Chandra data reveal a central point-like hard X-ray source (X-1) lying {approx}0.''4 SW from the kinematic center. Very accurate alignment between radio, infrared, and X-ray sources in the nuclear region shows that TH2, the IR photometric center, and X-1 are not associated with each other. As the kinematic center is consistent with the positions of TH2 and X-1, and both could be a manifestation of nuclear activity, we consider the two as possible galactic nucleus candidates. Although TH2 is the strongest compact radio source in the nuclear region, it does not have any infrared, optical, or X-ray counterparts. If the kinematic center is associated with this source, by analogy we suggest that the nucleus of NGC 253 resembles our Galactic center Sgr A*. On the other hand, X-1 is a heavily absorbed object (N{sub H} = 7.5 x 10{sup 23} cm{sup -2}) only detected at energies >2 keV (L{sub 2-10{sub keV}} {approx} 10{sup 40} erg s{sup -1}). If X-1 is instead associated with the kinematic center, the nucleus of NGC 253 is compatible with an obscured low-luminosity active galactic nucleus (AGN) or a spatially resolved super star cluster (SSC) brightening up in X-rays most probably due to young supernovae or supernova remnants, a situation also observed in the nuclear starburst of M82. If no SSC is associated with the kinematic center, we conclude that NGC 253 is a galaxy in which a strong starburst and a weak AGN (either TH2 or X-1) coexist. Results from few other high-resolution studies of nearby starburst galaxies (e.g., M82, NGC 5253, NGC 4945) indicate that the AGN in these systems, if present, is always in the low-luminosity regime. This may indicate that the onset of nuclear activity in galaxies is closely related with the occurrence of star formation, and that we are witnessing the emergence or disappearance of an AGN.

79 ASTRONOMY AND ASTROPHYSICS↗

Bond-length dependence of attosecond ionization delays in O 2 arising from electron correlation to a shape resonance

We experimentally and theoretically demonstrate that electron correlation can cause the bond-length sensitivity of a shape resonance to induce an unexpected vibrational state–dependent ionization delay in a nonresonant channel. This discovery was enabled by a high-resolution attosecond-interferometry experiment based on a 400-nm driving and dressing wavelength. The short-wavelength driver results in a 6.2–electron volt separation between harmonics, markedly reducing the spectral overlap in the measured interferogram. We demonstrate the promise of this method on O 2 , a system characterized by broad vibrational progressions and a dense photoelectron spectrum. We measure a 40-attosecond variation of the photoionization delays over the X 2 Π g vibrational progression. Multichannel calculations show that this variation originates from a strong bond-length dependence of the energetic position of a shape resonance in the b 4 Σ$^{-}_{g}$ channel, which translates to the observed effects through electron correlation. The unprecedented energy resolution and delay accuracies demonstrate the promise of visible-light–driven molecular attosecond interferometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CHERENCUBE: Concept definition and implementation challenges of a Cherenkov-based detector block for PET

Purpose: A new concept for a depth-of-interaction (DOI) capable time-of-flight (TOF) PET detector is defined, based only on the detection of Cherenkov photons. The proposed “CHERENCUBE” consists of a cubic Cherenkov radiator with position-sensitive photodetectors covering each crystal face. By means of the spatial distribution of the detected photons and their time of arrival, the point of interaction of the gamma-ray in the crystal can be determined. This study analyzes through theoretical calculations and Monte Carlo simulations the potential advantages of the concept toward reaching a Cherenkov-only detector for TOF-PET with DOI capability. Furthermore, an algorithm for the DOI estimation is presented and the requirements for a practical implementation of the proposed concept are defined. Methods: The Monte Carlo simulations consisted of a cubic crystal with one photodetector coupled to each one of the faces of the cube. The sensitive area of the detector matched exactly the crystal size, which was varied in 1 mm steps between 1 × 1 × 1 mm{sup 3} and 10 × 10 × 10 mm{sup 3}. For each size, five independent simulations of ten thousand 511 keV gamma-rays were triggered at a fixed distance of 10 mm. The crystal chosen was PbWO{sub 4}. Its scintillation properties were simulated, but only Cherenkov photons were analyzed. Photodetectors were simulated having perfect photodetection efficiency and infinite time resolution. For every generated particle, the analysis considered its creation process, parent and daughter particles, energy, origin coordinates, trajectory, and time and position of detection. The DOI determination is based on the distribution of the emission time of all photons per event. These values are calculated as a function of the coordinates of detection and origin for every photon. The common origin is estimated by finding the distribution with the most similar emission time-points. Results: Detection efficiency increases with crystal size from 8.2% (1 × 1 × 1 mm{sup 3}) to 58.6% (10 × 10 × 10 mm{sup 3}) and decreases applying a photon detection threshold of 5/10/20 photons to 6.3%/4.3%/0.7% and 49.3%/30.4%/2.8%, respectively. The detection rate in the six photodetectors is uniform due to the nearly isotropic cone emission. Most cones originated after a photoelectric effect interaction, with two dominating peaks for the kinetic energy of the electron at 422.99 and 441.47 keV. The detection distance between same-event photons defines the spatial resolution of the detector required for individual photon recognition, with 20% of the detected photons having their closest neighbor within a distance of 5% of the length of the cube. Same-event photons are detected within a time window whose width is determined by the crystal size, with values of 30 and 150 ps for a 1 × 1 × 1 mm{sup 3} and a 10 × 10 × 10 mm{sup 3} cube, respectively. The DOI reconstruction has an accuracy of approximately 23% of the length of the cube, with an average value of 2.2 mm for a 10 × 10 × 10 mm{sup 3} CHERENCUBE. Conclusions: The proposed concept requires a detector with high photodetection efficiency. The structure of the sensitive surface of the detector should be a two dimensional array of microcells, able to provide individual detection coordinates and time stamps. The microcell size determines the ability to recognize individual photons, influencing detection efficiency. The 3D DOI recognition relies on the accuracy of the time stamps and detection coordinates, without the need for a recognition of the projected patterns of photons. The refractive index of the material defines a detector intrinsic energy-based rejection of scattered PET events at the cost of reduced sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A passing rate of 99% was measured in areas of above 40% of the prescription dose. The final inverse treatment plan was comprised of 43 beams ranging from 5 to 12.5 mm in diameter (2.5 mm size increments are available up to 15 mm in diameter collimation). Using the Xsight Spine Tracking module, the CyberKnife system could not reliably identify and track the tiny mouse spine; however, the CyberKnife system could identify and track the fiducial markers on the 3D mold.In vivo positional accuracy analysis using the 3D mold generated a mean error of 1.41 mm ± 0.73 mm when fiducial markers were used for position tracking. Analysis of the dissected brain confirmed the ability to target the correct brain volume. Conclusions: With the use of a stereotactic body mold with fiducial markers, microCT imaging, and resolution down-sampling, the CyberKnife system can successfully perform small-animal radiotherapy studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-189: A Method to Improve the Spatial Resolution of Prompt Gamma Based Compton Imaging for Proton Range Verification

Purpose: To test two new techniques, the distance-of-closest approach (DCA) and Compton line (CL) filters, developed as a means of improving the spatial resolution of Compton camera (CC) imaging. Methods: Gammas emitted from {sup 22}Na, {sup 137}Cs, and {sup 60}Co point sources were measured with a prototype 3-stage CC. The energy deposited and position of each interaction in each stage were recorded and used to calculate a “cone-of-origin” for each gamma that scattered twice in the CC. A DCA filter was developed which finds the shortest distance from the gamma’s cone-of-origin surface to the location of the gamma source. The DCA filter was applied to the data to determine the initial energy of the gamma and to remove “bad” interactions that only contribute noise to the image. Additionally, a CL filter, which removes gamma events that do not follow the theoretical predictions of the Compton scatter equation, was used to further remove “bad” interactions from the measured data. Then images were reconstructed with raw, unfiltered data, DCA filtered data, and DCA+CL filtered data and the achievable image resolution of each dataset was compared. Results: Spatial resolutions of ∼2 mm, and better than 2 mm, were achievable with the DCA and DCA+CL filtered data, respectively, compared to > 5 mm for the raw, unfiltered data. Conclusion: In many special cases in medical imaging where information about the source position may be known, such as proton radiotherapy range verification, the application of the DCA and CL filters can result in considerable improvements in the achievable spatial resolutions of Compton imaging.

60 APPLIED LIFE SCIENCES↗

Theoretical simulation of solar spectra in the middle ultraviolet and visible for atmospheric trace constituent measurements

Two balloon flights reaching float altitudes of approximately 30 and 40 km respectively, were used to obtain scans of the ultraviolet and visible solar spectra. Both flights covered the UV (2800-3500A) at approximately 0.3A resolution and the visible at approximately 0.6A. Numerous scans were obtained during ascent and from float for both flights. All spectral scans obtained at float, from high sun to low sun, were calibrated in wavelength by using several standard solar spectra for line position references. Comparisons of low sun scans and high sun scans show significant atmospheric continuum extinction and have the potential of being used to identify atmospheric lines superimposed on the attenuated solar spectrum. The resolution was mathematically degraded to approximately 5A to better see the broad band atmospheric extinction. This low resolution is also appropriate for the available low resolution absorption coefficients of NO2 and O3, allowing the identification of NO2 and O3 features on the sunset spectra.

Goldman, A.↗

Structural improvement of unliganded simian immunodeficiency virus gp120 core by normal-mode-based X-ray crystallographic refinement

The structural model of the unliganded and fully glycosylated simian immunodeficiency virus gp120 core determined to 4.0 Å resolution was substantially improved using a recently developed normal-mode-based anisotropic B-factor refinement method. The envelope protein gp120/gp41 of simian and human immunodeficiency viruses plays a critical role in viral entry into host cells. However, the extraordinarily high structural flexibility and heavy glycosylation of the protein have presented enormous difficulties in the pursuit of high-resolution structural investigation of some of its conformational states. An unliganded and fully glycosylated gp120 core structure was recently determined to 4.0 Å resolution. The rather low data-to-parameter ratio limited refinement efforts in the original structure determination. In this work, refinement of this gp120 core structure was carried out using a normal-mode-based refinement method that has been shown in previous studies to be effective in improving models of a supramolecular complex at 3.42 Å resolution and of a membrane protein at 3.2 Å resolution. By using only the first four nonzero lowest-frequency normal modes to construct the anisotropic thermal parameters, combined with manual adjustments and standard positional refinement using REFMAC5, the structural model of the gp120 core was significantly improved in many aspects, including substantial decreases in R factors, better fitting of several flexible regions in electron-density maps, the addition of five new sugar rings at four glycan chains and an excellent correlation of the B-factor distribution with known structural flexibility. These results further underscore the effectiveness of this normal-mode-based method in improving models of protein and nonprotein components in low-resolution X-ray structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy of estimation of parameters with LISA

We present the results of the estimation of parameters with LISA for nearly monochromatic gravitational waves in the low and high frequency regimes for the time-delay interferometry response. Angular resolution of the detector and the estimation errors of the signal's parameters in the high frequency regimes are calculated as functions of the position in the sky and as functions of the frequency. For the long-wavelength domain we give compact formulas for the estimation errors valid on a wide range of the parameter space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Position-sensitive Transition-edge Sensor X-ray Detectors

We report on the development of position-sensitive transition-edge sensors (PoST's) for future x-ray astronomy missions such as the International X-ray Observatory (IXO), currently under study by NASA and ESA. PoST's consist of multiple absorbers each with a different thermal coupling to one or more transition-edge sensor (TES). This differential thermal coupling between absorbers and TES's results in different characteristic pulse shapes and allows position discrimination between the different pixels. The development of PoST's is motivated by a desire to achieve maximum focal-plane area with the least number of readout channels and as such. PoST's are ideally suited to provide a focal-plane extension to the Constellation-X microcalorimeter array. We report the first experimental results of our latest one and two channel PoST's, which utilize fast thermalizing electroplated Au/Bi absorbers coupled to low noise Mo/Au TES's - a technology already successfully implemented in our arrays of single pixel TES's. We demonstrate 6 eV energy resolution coupled with spatial sensitivity in the keV energy range. We also report on the development of signal processing algorithms to optimize energy and position sensitivity of our detectors.

Smith, S. J.↗

Stabilization of Th{sup 3+} ions into mixed-valence thorium fluoride

The unusual oxidation state +3 of the thorium has been stabilized into a lithium containing non-stoichiometric mixed-valence (III/IV) thorium fluorinated phase with formula Li{sub 2+x}Th{sub 12}F{sub 50} (0<x<1.8). This phase is closely related to the Li{sub 5.5}Ce{sub 12}F{sub 50} one, the structure of which has been determined from the combined single-crystal X-ray diffraction and high resolution synchrotron powder diffraction. In these phases, the Li{sup +} ions can be divided into two groups and are located either in locked positions or in open channels of the three dimensional framework. The amount of Li{sup +} ions in open channels can be variable, so that the afore mentioned single phase may be considered as an insertion compound. The Li{sup +} insertion is accompanied by the simultaneous reduction of a part of the Th{sup 4+} ions, resulting in a mixed-valence III/IV thorium fluoride. The electrochemical insertion of Li{sup +} ions into the open channels of the host matrix has been carried out at 60 {sup o}C, using an alkylcarbonate PC-LiClO{sub 4} 1 M electrolyte. The Li{sup +} and Th{sup 3+} contents, both in the starting composition and the Li{sup +} inserted ones, were investigated by high resolution solid state {sup 7}Li NMR and EPR, respectively. -- Graphical abstract: Electrochemical insertion of Li{sup +} ions into mixed-valence III/IV thorium fluoride and EPR spectra for the raw and inserted compounds. Display Omitted

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Radial resolution enhancement of the NSTX Thomson scattering diagnostic

Current magnetic confinement plasma physics research has increased the demand for radial resolution in profile diagnostics, in particular in the edge and pedestal regions. On NSTX, an upgrade of the existing multi-point Thomson scattering diagnostic has been implemented in order to respond to the research program needs. Twelve new radial channels have been added bringing the total number of positions to 42. Four previously un-instrumented fiber bundles were put in service. Eight existing 'active' fiber bundles were divided in two sub-bundles each in order to increase spatial resolution. Twelve radial channels now cover the pedestal region with a resolution near one centimeter. Fifteen radial channels cover the core and internal transport barrier regions. Two additional channels were added, one near the inner edge and one in the outer scrape-off layer. The intersection of the focused viewing optics field of view with a finite-width laser beam results in major-radius cross talk between adjacent fiber sub-bundles. A discussion and calculation of the cross talk will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and Manufacture of Tunable Permanent Magnet Based Quadrupole for Next Generation Electron-Ion Colliders [Slides]

The goal of this project is to design and construct of a prototype of quadrupole permanent magnet for the magnet transport lattice for an electron-ion collider. The technical objectives are not only to achieve the field gradient of 34.42T/m in the region of interest, at a radius 16.0mm, relative to the quadrupole axis (z-axis), but also lower the unwanted field harmonics below one unit out of 10,000, especially for Sextupole, Octupole, and Decapole components. The innovation is 1) modular design for cost saving, and 2) adjusting mechanism of each modular magnet for field tuning. The 300-mm long, quadrupole magnet assembly consists of 12 modules of 100-mm long magnet. The magnetic field tuning was implemented by two ways: first, adjusting mechanically the pole tip position for a majority of field tuning, and second, applying the passive shims for a fine field tuning. The magnetic design and optimization of the quadrupole magnet was performed using finite element analysis. The permanent magnet choice was EEC-N44SH grade with the minimum coercivity of 987kA/m (12.4kOe), which has enhanced resistance to demagnetization due to the radiation. The 3D computer-aided design of quadrupole magnet assembly was created based on the magnetic design results. The overall dimensions are 514x500x300mm and its weight is ~470kg (1,050lbs). The weight and volume were minimized through the optimization. Electron Energy Corporation’s vertically integrated manufacturing capability and over 48-years magnet production experience enabled us to implement a “fast prototyping” process and build two quadrupole magnets. Using wire EDM machines, the pole tip profile was precisely fabricated within ±25µm tolerance. The field gradient 34.22T/m was measured using the real time data acquisition system and a 3D Hall probe mounted on the precision XYZ station with the resolution of 1µm (0.00004”). The magnetic field harmonics were measured using a harmonic coil at the Brookhaven National Laboratory, Upton, NY. Faro® laser tracker was used to track the position of each quadrupole while adjusting the pole location mechanically. The normal harmonics were measured up to 20-poles. Overall the 2 nd magnet test data is better than the 1st magnet because of a better symmetry. The adjusting pole technique was proved effective to lower the Sextupole harmonics from -3.14 to -0.71 unit. The Octupole harmonics was improved from -5.67 to -3.45 unit, still not satisfactory. It is found that the proposed approach is not practical and efficient in terms of the mass production although the modular concept can save the manufacturing cost. Another finding is in reality it is hard to adjust mechanically due to the limit of laser tracker resolution .001” and tweak magnetically the field due to the limited harmonics data. Importantly the Brookhaven National Laboratory’s harmonics data doesn’t indicate where the strong/weak field position, which requires another field map test at each measurement. To resolve these, two alternative solutions are introduced; 1) electromagnet correcting coils and 2) 8-pieces quadrupole magnet.

43 PARTICLE ACCELERATORS↗

Multispectrum Analysis of the v4 Band of CH3CN: Positions, Intensities, Self and N2 Broadening and Pressure-Induced Shifts

A multispectrum nonlinear least squares fitting technique has been applied to measure accurate zero-pressure line center positions, Lorentz self- and N2-broadening coefficients and self- and N2-pressure-induced shift coefficients in the parallel ν4 band of CH3CN near 920 cm-1. Fifteen high-resolution (0.0029 cm-1) laboratory absorption spectra of pure and N2-broadened CH3CN recorded at room temperature using the Bruker IFS 125HR Fourier transform spectrometer located at the Pacific Northwest National Laboratory (PNNL) in Richland, Washington, U.S.A. were analyzed simultaneously. Short spectral intervals containing manifolds of transitions from the same value of J have been fitted together. In all, we have obtained high precision line positions, absolute line intensities, self- and N2-broadening coefficients for P(44) through P(3) and R(0) through R(46) manifolds. All measurements have been fitted successfully assuming a Voigt line shape. Preliminary fits of line intensities up to J = 47 using one principal dipole moment derivative and three Herman-Wallis terms are reported. The results are not fully satisfactory due to perturbations caused by interactions with other bands. The total intensity obtained from this prediction by summing individual line intensities for the v4 band region has been compared with the integrated absorption coefficient reported for the v4 band from lower resolution spectra measured at the same laboratory facility. The variations of N2 broadening, self-broadening, N2- shift and self-shift coefficients with the J and K quantum numbers have been measured for the first time. N2-broadening coefficients decrease with increasing J and K. Some self-broadening coefficients are very large (up to ~2 cm-1 atm-1 at 294 K). Ratios of N2-broadening coefficients to self-broadening coefficients show a compact distribution with rotational quantum number in both the P- and R-branches that range from ~0.45 to 15 with a maxima ratio near J"=13. Pressure-induced shifts for N2 are small (few exceed ±0.006 cm-1 atm-1 at 294 K). In contrast, self-shift coefficients are large (maxima of about ±0.06 cm-1 atm-1) and are both positive and negative with compact and distributions as a function of rotational quantum number. A calculation of the total internal partition function sum has been performed and those results have been made available for addition to the HITRAN and GEISA databases. We discuss the status of assignments for CH3CN that are currently available for other mid- and far infrared regions

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dual Polarity Ion Confinement and Mobility Separations

Structures for Lossless Ion Manipulations (SLIM) have been rapidly gaining prominence for applications where ultra-high resolution Ion Mobility (IM) separations are desired to provide performance features and information unattainable using the currently available IM platforms. Although most routine analyses are done in either positive or negative polarity modes, there are significant benefits to both, potentially making them highly complementary if performed simultaneously. In the effort to develop a robust dual polarity IM platform, we explored an evaluation of a novel SLIM platform developed to perform simultaneous cationic and anionic IM separations (i.e. without requiring polarity switching).

Attah, Isaac K.↗