Search NASA⌕ Search

SEARCH · Search NASA

Results for “Process monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Gamma radiation-induced blue shift of resonance peaks of Bragg gratings in pure silica fibres

We report the first observation of a significant gamma radiation-induced blue shift of the reflection/transmission peak of fibre Bragg gratings inscribed into pure-silica core fibres via multiphoton absorption of femtosecond pulses. At a total dose of ∼100 kGy, the shift is ∼20 pm. The observed effect is attributable to the ionising radiation-induced decrease in the density of the silica glass when the rate of colour centre formation is slow. We present results of experimental measurements that provide the key parameters of the dynamics of the gratings for remote dosimetry and temperature sensing. (laser crystals and braggg ratings)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of haemodilution on the optical properties of blood during coagulation studied by optical coherence tomography

We report an investigation of the effects of blood dilution with hypertonic (7.5 %) and normal (0.9 %) saline on its optical properties during coagulation in vitro using optical coherence tomography. The light penetration depth and attenuation coefficient are obtained from the dependences of reflectance on the depth. Normal whole blood has served as the control group. The average coagulation time is equal to 420±16,418±16 and 358±14 s with blood volume replacement of 2 %, 11 %, and 20 % by 0.9 % normal saline, respectively. With 2 %, 11% and 20% blood volume replacement with 7.5 % hypertonic saline, the average coagulation time is 422±17,1160±45 and 1730±69 s, respectively. For normal whole blood, the average coagulation time amounts to 425±19 s. it is shown that dilution with normal saline has a procoagulant effect when it replaces 20 % of blood volume, and hypertonic saline has an anticoagulant effect if it replaces 11 % or more of blood volume. It is concluded that optical coherence tomography is a potential technique to quantify and monitor the liquid – gel transition during the coagulation process of blood diluted by normal and hypertonic saline. (biophotonics)

60 APPLIED LIFE SCIENCES↗

Chemical bond reorganization in intramolecular proton transfer revealed by ultrafast X-ray photoelectron spectroscopy

Time-resolved X-ray photoelectron spectroscopy (TR-XPS) is used in a simulation study to monitor the excited state intramolecular proton transfer between oxygen and nitrogen atoms in 2-(iminomethyl)phenol. Real-time monitoring of the chemical bond breaking and forming processes is obtained through the time evolution of excited-state chemical shifts. By employing individual atomic probes of the proton donor and acceptor atoms, we predict distinct signals with opposite chemical shifts of the donor and acceptor groups during proton transfer. Details of the ultrafast bond breaking and forming dynamics are revealed by extending the classical electron spectroscopy chemical analysis to real time. Through a comparison with simulated time-resolved photoelectron spectroscopy at the valence level, the distinct advantage of TR-XPS is demonstrated thanks to its atom specificity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Raman spectroscopy of oxygen carrier particles in harsh environments

Fossil fuel combustion processes generate CO2, a greenhouse gas of considerable concern. To reduce this emission, the National Energy Technology Laboratory (NETL) is evaluating alternative combustion approaches, including chemical looping combustion (CLC). This technique generates relatively pure CO2, suitable for subsequent capture and storage. CLC uses oxygen-carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide oxygen for the combustion process. Optimization of the overall combustion process requires knowledge of the oxidation state (e.g., content of Fe2O3 vs. Fe3O4) of the OCPs during the different stages of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of OCPs in harsh environments is lacking and new sensors need to be developed. We are evaluating non-contact, stand-off Raman spectroscopy to determine the relative concentrations of the oxidized and reduced forms of OCPs at temperatures between 800 °C and 1000 °C, and pressures of about 10 atm. Using cw and pulsed Raman spectroscopy, in combination with a pressurized high-temperature sample chamber, we have optimized the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, etc. and measured Raman spectra of various OCP materials at high temperatures. To extract from the Raman spectra relevant information such as the concentration ratio of a material in different oxidation states, the measured data needs to be processed, and statistical modeling and multivariate calibration need to be performed.

20 FOSSIL-FUELED POWER PLANTS↗

SU-G-JeP4-10: Measurement of Prostate Motion Trajectories During Prostate SBRT Boost Treatments with a Rectafix

Purpose: To determine prostate motion during SBRT boost treatments with a Rectafix rectal sparing device in place using kV imaging during treatment. Methods: Patients each had three gold fiducial markers inserted into the prostate and received two VMAT boost fractions of 9.5–10 Gy under the PROMETHEUS clinical trial protocol with a Rectafix rectal retractor in place. Two-dimensional kilovoltage images of fiducial markers were acquired continuously during delivery. Three patients were treated on a Varian Clinac iX linear accelerator (6X, 600 MU/min), where kV images were acquired at 5 Hz during treatment. Seven patients were treated on a Varian Truebeam linear accelerator (10XFFF, 2400 MU/min) where kV images were acquired every 3 seconds. Images were processed off-line using the Kilovoltage Intrafraction Monitoring (KIM) software after treatment. KIM determines prostate position in three dimensions from 2D kV projections using a probability density model and a pre-treatment kV arc. The 3D displacement of the prostate was quantified as a function of time throughout each fraction. Results: From all fractions analyzed, it was found that the prostate had moved less than 1 mm in any direction from its initial position 84.6% of the time. The prostate was between 1 and 2 mm from its initial position 14.2% of the time, between 2 and 3 mm of its initial position 0.8% of the time and was greater than 3 mm from its initial position only 0.4% of the time. Conclusion: The amount of prostate motion observed during prostate SBRT boost treatments with a Rectafix device in place was minimal and lower than that observed in non-Rectafix studies. The Rectafix device reduces rectal dose as well as immobilizing the prostate. Kimberley Legge is the recipient of an Australian Postgraduate Award.

60 APPLIED LIFE SCIENCES↗

Devices for Diagnostics and Lithium Collection on the T-11M and T-10 Tokamaks. First Results

The use of lithium as a material of the tokamak in-vessel plasma-facing components made it necessary to develop appropriate diagnostic instruments. For the T-10 and T-11M tokamaks, devices have been developed that allow one to investigate the processes of lithium transport in the tokamak scrape-off layer, the dynamics of lithium deposition at different temperatures of the collecting surface in real time by using a piezoelectric quartz detector, adsorption and desorption of the plasma-forming gas by lithium, and the influence of the electric field on the process of lithium collection. The plasma parameters are monitored using Langmuir probes. The developed devices can be used to extract lithium deposited on the tokamak vessel wall without breaking vacuum conditions. For these purposes, a gateway and a vacuum input without bellows have been designed on the basis of an innovative liquid-metal coupling.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation Source Mapping with Bayesian Inverse Methods

In this work, we present a method to map the spectral and spatial distributions of radioactive sources using a limited number of detectors. Locating and identifying radioactive materials is important for border monitoring, in accounting for special nuclear material in processing facilities, and in cleanup operations following a radioactive material spill. Most methods to analyze these types of problems make restrictive assumptions about the distribution of the source. In contrast, the source mapping method presented here allows an arbitrary three-dimensional distribution in space and a gamma peak distribution in energy. To apply the method, the problem is cast as an inverse problem where the system’s geometry and material composition are known and fixed, while the radiation source distribution is sought. A probabilistic Bayesian approach is used to solve the resulting inverse problem since the system of equations is ill-posed. The posterior is maximized with a Newton optimization method. The probabilistic approach also provides estimates of the confidence in the final source map prediction. A set of adjoint, discrete ordinates flux solutions, obtained in this work by the Denovo code, is required to efficiently compute detector responses from a candidate source distribution. These adjoint fluxes form the linear mapping from the state space to the response space. The test of the method’s success is simultaneously locating a set of 137 Cs and 60 Co gamma sources in a room. This test problem is solved using experimental measurements that we collected for this purpose. Because of the weak sources available for use in the experiment, some of the expected photopeaks were not distinguishable from the Compton continuum. However, by supplanting 14 flawed measurements (out of a total of 69) with synthetic responses computed by MCNP, the proof-of-principle source mapping was successful. The locations of the sources were predicted within 25 cm for two of the sources and 90 cm for the third, in a room with an ~4-x 4-m floor plan. Finally, the predicted source intensities were within a factor of ten of their true value.

07 ISOTOPE AND RADIATION SOURCES↗

Complexity and entropy representation for machine component diagnostics

The Complexity-entropy causality plane (CECP) is a parsimonious representation space for time series. It has only two dimensions: normalized permutation entropy and Jensen-Shannon complexity of a time series. This two-dimensional representation allows for detection of slow or rapid drifts in the condition of mechanical components monitored through sensor measurements. The CECP representation can be used for both predictive analytics and visual monitoring of changes in component condition. This method requires minimal pre-processing of raw signals. Furthermore, it is insensitive to noise, stationarity, and trends. These desirable properties make CECP a good candidate for machine condition monitoring and fault diagnostics. In this work we study the effectiveness of CECP on three rotary component condition assessment applications. We use CECP representation of vibration signals to differentiate various machine component health conditions for rotary machine components, namely roller bearing and gears. The results confirm that the CECP representation is able to detect, with high accuracy, changes in underlying dynamics of machine component degradation states. From class separability perspective, the CECP representation is able to generate linearly separable classes for the classification of different fault states. This classification performance improves with increasing signal length. For signal length of 16,384 data points, the fault classification accuracy varies from 90% to 100% for bearing applications, and from 85% to 100% for gear applications. We observed that the optimum parameter for CECP representating depends on the application. For bearing applications we found that embedding dimension D = 4, 5, 6, and embedding delay τ = 1, 2, 3 are suitable for good fault classification. For gear applications we find that embedding dimension D = 4, 5, and embedding delay τ = 1, 5 are suitable for fault classification.

47 OTHER INSTRUMENTATION↗

Lab-Scale Demonstration of Plutonium Purification by Anion Exchange, Plutonium(IV) Oxalate Precipitation, and Calcination to Plutonium Oxide to Support the MOX Feed Mission

H-Canyon and HB-Line are tasked with the production of PuO 2 from a feed of plutonium metal. The PuO 2 will provide feed material for the MOX Fuel Fabrication Facility. After dissolution of the Pu metal in H-Canyon, the solution will be transferred to HB-Line for purification by anion exchange. Subsequent unit operations include Pu(IV) oxalate precipitation, filtration and calcination to form PuO 2 . This report details the results from SRNL anion exchange, precipitation, filtration, calcination, and characterization tests, as requested by HB-Line1 and described in the task plan. This study involved an 80-g batch of Pu and employed test conditions prototypical of HB-Line conditions, wherever feasible. In addition, this study integrated lessons learned from earlier anion exchange and precipitation and calcination studies. H-Area Engineering selected direct strike Pu(IV) oxalate precipitation to produce a more dense PuO 2 product than expected from Pu(III) oxalate precipitation. One benefit of the Pu(IV) approach is that it eliminates the need for reduction by ascorbic acid. The proposed HB-Line precipitation process involves a digestion time of 5 minutes after the time (44 min) required for oxalic acid addition. These were the conditions during HB-line production of neptunium oxide (NpO 2 ). In addition, a series of small Pu(IV) oxalate precipitation tests with different digestion times were conducted to better understand the effect of digestion time on particle size, filtration efficiency and other factors. To test the recommended process conditions, researchers performed two nearly-identical larger-scale precipitation and calcination tests. The calcined batches of PuO 2 were characterized for density, specific surface area (SSA), particle size, moisture content, and impurities. Because the 3013 Standard requires that the calcination (or stabilization) process eliminate organics, characterization of PuO 2 batches monitored the presence of oxalate by thermogravimetric analysis-mass spectrometry (TGA-MS). To use the TGA-MS for carbon or oxalate content, some method development will be required. However, the TGA-MS is already used for moisture measurements. Therefore, SRNL initiated method development for the TGA-MS to allow quantification of oxalate or total carbon. That work continues at this time and is not yet ready for use in this study. However, the collected test data can be reviewed later as those analysis tools are available.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Aging Studies on Nitro-Plasticizer

Plasticizers are utilized with many polymers to increase fluidity. By adding a plasticizer to a polymer, the polymer changes from rigid and brittle to soft and flexible. NP is a nitro-plasticizer that is currently used with a wide variety of polymers. NP is a 50-50 mixture of bis(2,2–dinitropropyl) acetal (BDNPA) and bis(2,2 – dinitropropyl)formal (BDNPF) (Figure 1). Sometimes this combination is referred to as A/F but throughout the extent of this paper it will be referred to as NP. BDNPA and BDNPF have been researched separately to determine the decomposition rate of both compounds and what products are generated (3). BDNPF decomposes at a slower rate than BDNPA. It has been hypothesized that this is because BDNPF has a lower vapor pressure and is less sterically hindered (3). It is important to determine how the decomposition of NP will differ as it is a combination of both BDNPF and BDNPA. This particular combination of plasticizers is commonly used with polymers in explosive and propellant composite systems as an energetic plasticizer (3). Because of its applications; it is vital to study to effects of aging on NP to determine its stability over time. This research focuses on 3 and 6 month aged NP and the structural variations that occur due to the aging process. Previous studies suggest that NP is stable during low temperature storage (4), but this research focuses on the stability of NP at various different conditions to achieve the most comprehensive scope of the effect of the aging process. This is an ongoing process and this research will continue to be monitored for at least one year. Depending on the results obtained; the research may carry on for two years.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated research training program of excellence in radiochemistry

The overall goal of this “Integrated Research Training Program of Excellence in Radiochemistry” is to provide a rich and deep research experience in state-of-the-art radiochemistry and in the fundamentals of radioisotopic labeling and tracer methodology to develop researchers who are capable of meeting the challenges of designing and preparing radiotracers of broad applicability for monitoring and imaging diverse biological systems and environmental processes. This program was based in the Departments of Radiology and Radiation Oncology at Washington University Medical School and the Department of Chemistry at the University of Illinois at Urbana Champaign, and it was initially directed by Professor Michael J. Welch as Principal Investigator. After his passing in 2012, the program was led by Professor Suzanne E. Lapi. Programmatic content and participant progress was overseen by an Internal Advisory Committee of senior investigators consisting of the PIs, Professor Mach from the Department of Radiology at Washington University and Professor John A. Katzenellenbogen of the Department of Chemistry at the University of Illinois. A small External Advisory Committee to give overall program guidance was also constituted of experts in radiolabeled compounds and in their applications in environmental and plant science.

18F↗

Solvent hold tank sample results for MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017): Quarterly Report

A trend summary of three Solvent Hold Tank (SHT) monthly samples; MCU-16-1488-1493 (December 2016), MCU-17-86-88 (January 2017), and MCU-17-119-121 (February 2017) are reported. Analyses indicate that the modifier (CS-7SB) and the extractant (MaxCalix) concentrations are at their nominal recommended levels (169,000 mg/L and 46,300 mg/L respectively). The suppressor (TiDG) level has decreased to a steady state level of 673 mg/L well above the minimum recommended level (479 mg/L). This analysis confirms the Isopar™ addition to the solvent in January 18, 2017. This analysis also indicates the solvent did not require further additions. Based on the current monthly sample, the levels of TiDG, Isopar™L, MaxCalix, and modifier are sufficient for continuing operation but are expected to decrease with time. Periodic characterization and trimming additions to the solvent are recommended. No impurities above the 1000 ppm level were found in this solvent by the Semi-Volatile Organic Analysis (SVOA). No impurities were observed in the Hydrogen Nuclear Magnetic Resonance (HNMR). Another impurity observed in the samples was mercury. Up to 38 ± 8 micrograms of mercury per mL of solvent was detected in these samples (the average of the CV-AA and XRF methods). The higher mercury concentration in the solvent (as determined in the last three monthly samples) is possibly due to the higher mercury concentration in Salt Batches 8 and 9 (Tank 49H) or mixing of previously undisturbed areas of high mercury concentration in Tank 49H. The gamma level (0.21E5 dpm/mL) measured in the February SHT sample was one order of magnitude lower than the gamma levels observed in the December and January SHT samples. The February gamma level is consistent with the solvent being idle (since January 10, 2017). The gamma levels observed in the December and January SHT samples were consistent with previous monthly measurements where the process operated normally. The laboratory will continue to monitor the quality of the solvent in particular for any new impurities or degradation of the solvent components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design and Development of a Custom Laser Powder Bed Fusion System

Additive manufacturing (AM) has gained great momentum both in industrial and research applications. Due to the ability to create custom and complex parts directly from a computer-aided design (CAD) file, AM is becoming a more reliable and efficient means to fabricate components. While being implemented throughout the aerospace, medical, automotive, and energy industries, the development of metal AM is still ongoing and presents many unique scientific challenges. For example, in laser powder bed fusion (PBF), intense localized heating of metal powder followed by rapid cooling leads to residual stresses and unique microstructures within a build. This may lead to cracking and a decrease in mechanical performance. In-situ diagnostics enable the laser-material interaction to be monitored as it occurs in order to optimize process parameters, and can be leveraged to develop tailored materials with specific microstructures that are more conducive for the complex thermal patterns encountered during laser PBF. Unfortunately, most commercial laser PBF machines are not suitable for research applications due to their large size, lack of diagnostics, and black box operation. A smaller system is better suited for using smaller quantities of powder to develop new tailored materials for AM, and a custom, modular design permits greater flexibility for incorporating in-situ diagnostics. Therefore, this project consisted of the design and construction of a custom, small scale, modular PBF system.

36 MATERIALS SCIENCE↗

Raman Spectroscopy for the On Line Analysis of Oxidation States of Oxygen Carrier Particles

The need for cleaner energy systems, including CO 2 capture technologies, is driving the current development of new combustion approaches such as chemical looping combustion (CLC). This process is based on using oxygen carrier particles (OCPs) such as iron oxides, copper oxides, calcium sulfates, etc. to provide the oxygen for the combustion process. In order to optimize the overall process performance, it is critical that the properties of the oxygen carriers are well-defined and maintained for their specific purpose during the different stages of the CLC process. One of the critical properties of the oxygen carrier is its oxidation state (e.g., content of Fe 2 O 3 vs. Fe 3 O 4 ) as it affects the fundamental operation of the CLC process. Unfortunately, the ability to make on-line measurements of the oxidation state of oxygen carriers is lacking and new sensors need to be developed. Our goal is to develop a sensor for the on-line analysis of the oxidation state of oxygen carrier particles and to demonstrate its feasibility. Oxygen carrier particles (OCPs) of interest include iron oxides, copper oxides, and calcium sulfate, with particle sizes typically less than 0.5 mm diameter. The expected operating conditions of the sensor include OCP temperatures in the range of 800 °C to 1000 °C, and pressures of about 10 atm. The expected results are to be of a statistical nature, providing relative concentrations of the different oxidation states. These requirements make a strong case for using non-contact, stand-off, pulsed Raman spectroscopy as a sensor for the high-temperature on-line analysis of oxygen carrier particles. In order to achieve our goal, we have set up and tested a pulsed Raman spectroscopy system in combination with a pressurized high-temperature sample chamber, and have taking initial Raman spectra of various materials at high temperature. We are now in the process of optimizing the operating parameters such as laser wavelength, laser intensity, collection optic design, focal spot size, data acquisition, etc. We will also develop an analysis procedure for the interpretation of the Raman spectra. Typical Raman spectra consist of a convolution of background signal and multiple individual spectra. In order to extract relevant information such as the concentration ratio of a material in different oxidation states, we need to process (background subtraction, deconvolution, fitting, etc.) the measured data. In addition, statistical modeling and multivariate calibration need to be performed to correctly analyze the Raman spectra.

20 FOSSIL-FUELED POWER PLANTS↗

Instrumented Photovoltaic Modules for Environmental Characterization and Simulation Model Validation

Photovoltaic modules are subjected to various mechanical stressors in their deployment environments, ranging from installation handling to wind and snow loads. Damage incurred during these mechanical events has the potential to initiate subsequent degradation mechanisms, reducing useful module lifespan. Thus, characterizing the mechanical state of photovoltaic modules is pertinent to the development of reliable packaging designs. In this work, photovoltaic modules with strain gauges directly incorporated into the module laminate were fabricated and subjected to mechanical loading to characterize internal strains within the module when under load. These experimental measurements were then compared against results obtained by high-fidelity finite-element simulations. The simulation results showed reasonable agreement in the strain values over time; however, there were large discrepancies in the magnitudes of these strains. Both the instrumentation technique and the finite-element simulations have areas where they can improve. These areas of improvement have been documented. Despite the observed discrepancies between the experimental and simulated results, the module instrumentation proved to be a useful gauge in monitoring and characterizing the mechanical state. With some process improvements, this method could potentially be applied to other environments that a photovoltaic module will encounter in its lifetime that are known to cause damage and degrade performance.

14 SOLAR ENERGY↗

Homomorphic Encryption for Machine Learning and Artificial Intelligence Applications

Third-party and expert analysis is a cost-effective solution for solving specialized problems or processing large datasets related to reactor structural health monitoring and nondestructive evaluation. However, when handling proprietary information, third-party and expert analysts pose a privacy risk. To address this challenge, Homomorphic Encryption (HE) permits arithmetic operations on encrypted data without exposing the underlying data. Implementations of Machine Learning (ML) and Artificial Intelligence (AI) algorithms using HE greatly enhances the capabilities of third-party analysts while maintaining a low security risk. This paper details current success in applying Principal Component Analysis (PCA) and Fully Connected Neural Networks (NN) using the Microsoft SEAL implementation of the popular CKKS Fully Homomorphic Encryption (FHE) algorithm. The MNIST Handwritten Dataset is analyzed as a proof-of-concept demonstration of the implementations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Interpreting strain tensor data to characterize and monitor reservoirs for CO2 storage and other applications

Recent advances in instrumentation have made it feasible to measure the transient strain tensor caused by small changes in fluid volume or pressure in the subsurface and this has opened the door to new opportunities for characterization and monitoring. We have deployed strainmeters and then conducted injection well tests in an underlying reservoir at 530m depth. The resulting data indicated that the horizontal strain at shallow strainmeters (30 to 40m depth) was tensile and the vertical strain was compressive. The radial strain was less than the horizontal strain, and the strain rates decreased from 100 nanostrain/day to roughly 10 n/d over a few days. The signal at two strainmeters at shallow depth were consistent, although the magnitude of the horizontal strains were different reflecting the different radial directions from the well. The signal at a deep strainmeter deployed at reservoir depth was much different, with tensile vertical strains and compressive horizontal strains. These data can be interpreted by inverting poroelastic forward models developed using numerical and analytical methods. The average horizontal strain in the caprock resembles the transient pressure in the underlying reservoir and classic type-curve methods from transient well testing can be used for preliminary interpretations of strain data. We have developed closed-form analytical solutions to a pressurized poroelastic inclusion and inhomogeneity in a half-space. This model is fast and can be inverted to estimate reservoir stiffness and geometry. Numerical models developed using finite element methods allow more details of the subsurface to be included in the inversion, but they require much longer run times and this makes inversion cumbersome using standard methods. We have developed an inversion approach that uses a proxy model created using machine learning to do most of the forward calculations. The proxy model is periodically updated and refined using the finite element model to ensure accuracy. This approach significantly reduces the computational requirements and makes it feasible to use Bayesian inversion with large numerical models. We have shown that the strain tensor in the caprock is sensitive to pressure in the reservoir, boundaries in the reservoir, and pressure in the caprock caused by leaks. These results indicate that coupling strain tensor data with inversion has the potential to help evaluate reservoirs during initial characterization, and to monitor them during the CO2 injection and storage process.

Murdoch, Larry↗