Search NASA⌕ Search

SEARCH · Search NASA

Results for “Project X”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

NASA GRC Solar Cell Characterization Facilities

NASA GRC maintains various equipment to calibrate and characterize photovoltaic devices to Air Mass Zero standards and different space-simulated environments. These characterization capabilities are critical to developing and advancing photovoltaic devices, allowing advancements in various NASA-related projects (Artemis, Lunar Gateway, Human Landing System, etc.). Our facilities include an X-25 Triple source Solar Simulator, G2V Sunbrick, Angstrom Designs pLEDss (Programmable LED Solar Simulator), Thermal Balance facility, ER-2 High Altitude aircraft calibration.

Photovoltaic↗

Solar Research Spotlight: Systems Integration

This Solar Energy Technologies Office fact sheet provides an overview of the systems integration subprogram, which funds research and development projects in five broad, interrelated focus areas: planning and operation, solar plus X, power electronics, sensing and communication, and codes and standards.

Solar Energy Technologies Office fact sheet, syste↗

HOT AND COLD GALACTIC GAS IN THE NGC 2563 GALAXY GROUP

The role of environmentally induced gas stripping in driving galaxy evolution in groups remains poorly understood. Here we present extensive Chandra and Very Large Array mosaic observations of the hot and cold interstellar medium within the members of the nearby, X-ray bright NGC 2563 group, a prime target for studies of the role of gas stripping and interactions in relatively small host halos. Our observations cover nearly all group members within a projected radius of 1.15 Mpc ({approx}1.4 R{sub vir}) of the group center, down to a limiting X-ray luminosity and H I mass of 3 Multiplication-Sign 10{sup 39} erg s{sup -1} and 2 Multiplication-Sign 10{sup 8} M{sub Sun }, respectively. The X-ray data are consistent with efficient ram pressure stripping of the hot gas halos of early-type galaxies near the group core, but no X-ray tails are seen and the limited statistics preclude strong conclusions. The H I results suggest moderate H I mass loss from the group members when compared to similar field galaxies. Six of the 20 H I-detected group members show H I evidence of ongoing interactions with other galaxies or with the intragroup medium. Suggestive evidence is further seen for galaxies with close neighbors in position-velocity space to show relatively low H I content, consistent with tidal removal of H I. The results thus indicate removal of both hot and cold gas from the group members via a combination of ram pressure stripping and tidal interactions. We also find that 16 of the 20 H I detections occur on one side of the group, reflecting an unusual morphological segregation whose origin remains unclear.

79 ASTRONOMY AND ASTROPHYSICS↗

DEVELOPMENT OF ASME SECTION X CODE RULES FOR HIGH PRESSURE COMPOSITE HYDROGEN PRESSURE VESSELS WITH NON-LOAD SHARING LINERS

The Boiler and Pressure Vessel Project Team on Hydrogen Tanks was formed in 2004 to develop Code rules to address the various needs that had been identified for the design and construction of up to 15000 psi hydrogen storage vessel. One of these needs was the development of Code rules for high pressure composite vessels with non-load sharing liners for stationary applications. In 2009, ASME approved new Appendix 8, for Section X Code which contains the rules for these vessels. These vessels are designated as Class III vessels with design pressure ranging from 20.7 MPa (3,000 ps)i to 103.4 MPa (15,000 psi) and maximum allowable outside liner diameter of 2.54 m (100 inches). The maximum design life of these vessels is limited to 20 years. Design, fabrication, and examination requirements have been specified, included Acoustic Emission testing at time of manufacture. The Code rules include the design qualification testing of prototype vessels. Qualification includes proof, expansion, burst, cyclic fatigue, creep, flaw, permeability, torque, penetration, and environmental testing.

08 HYDROGEN↗

Optical detection of the Pictor A jet and tidal tail: Evidence against an IC/CMB JET

New images of the FR II radio galaxy Pictor A from the Hubble Space Telescope reveal a previously undiscovered tidal tail, as well as a number of jet knots coinciding with a known X-ray and radio jet. The tidal tail is approximately 5″ wide (3 kpc projected), starting 18″ (12 kpc) from the center of Pictor A, and extends more than 90″ (60 kpc). The knots are part of a jet observed to be about 4′ (160 kpc) long, extending to a bright hotspot. These images are the first optical detections of this jet, and by extracting knot flux densities through three filters, we set constraints on emission models. While the radio and optical flux densities are usually explained by synchrotron emission, there are several emission mechanisms that might be used to explain the X-ray flux densities. Our data rule out Doppler-boosted inverse Compton scattering as a source of the high-energy emission. Instead, we find that the observed emission can be well described by synchrotron emission from electrons with a low-energy index (p∼2) that dominates the radio band, while a high-energy index (p∼3) is needed for the X-ray band and the transition occurs in the optical/infrared band. This model is consistent with a continuous electron injection scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

Technetium Reduction and Permanent Sequestration by Abiotic and Biotic Formation of Low-Solubility Sulfide Mineral Phases

One way to minimize the mobility of the Tc VII oxyanion pertechnetate (TcO 4 - ) is to effect reduction under sulfidogenic conditions (generated abiotically by Fe 0 or biotically) to form TcS x , which is significantly slower to oxidize than Tc IV O 2 . In sediment systems, TcS x and other precipitates may oxidize more slowly due to oxygen diffusion limitations to these low permeability precipitate zones. In addition, the TcO 4 - reduction rate may be more rapid in the presence of sediment because of additional reductive surface phases. This project aims to provide a fundamental understanding of the feasibility of immobilization of TcO 4 - as TcS x in the vadose zone or groundwater by application nano zero-valent iron (nZVI), and sulfide or sulfate. Biotic batch experiments have used the sulfate-reducing bacterium (SRB) Desulfotomaculum reducens . The iron sulfide mineral mackinawite was generated under these conditions, while vivianite was formed in nZVI only controls. The sulfide/bacteria-containing system consistently reduced aqueous pertechnetate rapidly (> 95% in the first hour), a rate similar to that for the sulfide-free, nZVI only system. Reduced Tc (aged for 3 months) generated in both SRB/nZVI systems was highly resistant to reoxidation. In reduced samples, Tc was found associated with solid phases containing Fe and S (D. reducens/nZVI) or Fe (nZVI only). Experiments using D. reducens without nZVI provided some additional insights. Firstly, stationary phase cultures were able to slowly reduce pertechnetate. Secondly, addition of pertechnetate at the beginning of cell growth (lag phase) resulted in a faster rate of Tc reduction, possibly indicating a direct (e.g. enzymatic) role for D. reducens in Tc reduction. Abiotic batch experiments were conducted with Na 2 S as the sulfide source. Pertechnetate reduction was rapid in the presence of sulfide and nZVI, although the rate was suppressed at the higher S/Fe ratios tested. This suppression appeared to be due to the formation of Tc-containing colloids. As with the biotic experiments, pertechnetate reduced under sulfidic conditions was highly resistant to reoxidation. The microscopic morphology of abiotically-transformed nZVI particles varied significantly with those in the biotic experiment, although mackinawite was formed in both systems (as indicated by μXRD and Mössbauer spectroscopy). Preliminary XAS analysis pointed to a mixture of Tc-O and Tc-S binding in the abiotic sulfide/nZVI system, while the major reduced solids under non-sulfidic conditions were TcO 2 •nH 2 O. The presence of sediment and advective flow to the TcO 4 - /nZVI/sulfide system results in additional processes occurring. Although the natural Hanford sediment used has sufficient available ferrous iron to slowly reduce TcO 4 - , under anaerobic conditions, that rate is orders of magnitude slower than reduction by nZVI/sulfide. Batch and 1-D column experiments showed that the TcO 4 - reduction rate increased with the sediment surface area (with the same nZVI mass). As in batch systems, column studies showed that the presence of sulfide with TcO 4 - at low (2-5 mM) concentrations increased the TcO 4 - reduction rate and high (10-30 mM) sulfide decreased the rate. This change is attributed to the formation of sulfide precipitates on the nZVI and sediment surfaces. Injection of low and high sulfide (i.e. pretreatment) prior to TcO 4 - /sulfide injection also greatly decreased the TcO 4 - reduction rate, likely decreasing the generation of ferrous iron from the nZVI. Although the high sulfide systems have slower Tc reduction rates, 190 times more Tc mass precipitated than in the low sulfide systems and the highest fraction of Tc mass remained immobilized.

54 ENVIRONMENTAL SCIENCES↗

A study of sacrificial mirrors for use prior to a laser wakefield accelerator driven by the Z-Petawatt laser

Many experiments at Sandia’s Z Pulsed Power Facility require x-ray backlighting diagnostics to understand experiment performance. Due to limitations in present-day source/detection modalities, most x-ray diagnostics at Z are restricted to photon energies <20 keV, ultimately limiting the density, amount, and atomic number of targets diagnosable in experiments. These limitations force the use of low-Z materials like Beryllium, and they prevent acquisition of important backlighting data for materials/densities that are opaque to soft x-rays and where background emission from the Z load and transmission lines overwhelm diagnostics. In this LDRD project, we have investigated the design and development of a laser wakefield acceleration platform driven by the Z-Petawatt laser – a platform that would enable the generation of a pulsed, collimated beam of high energy x-rays up to 100 keV. Geometrical considerations for implementation on the Z Machine require the use of sacrificial mirrors, which have been tested in offline experiments in the Chama target chamber in building 983. Our results suggest the use of sacrificial mirrors would not necessarily inhibit the laser wakefield x-ray process, particularly with the benefits stemming from planned laser upgrades. These conclusions support the continuation of laser wakefield source research and the development of the necessary infrastructure to deliver the Z-Petawatt laser to the Z center section along the appropriate lines of sight. Ultimately, this new capability will provide unprecedented views through dense states of matter, enabling the use of previously incompatible target materials/designs, and uncovering a new set of observables accessible through diffraction and spectroscopy in the hard x-ray regime. These will amplify the data return on precious Z shots and enhance Sandia’s ability to investigate fundamental physics in support of national security.

43 PARTICLE ACCELERATORS↗

The New Modular High-Energy X-ray Source Facility Shielding Design

Several new research facilities will soon be constructed as part of the creation of a new engineering complex on the campus of the University of Tennessee, Knoxville (UTK). As part of this renovation, a state of the art nuclear engineering building will be constructed. This building will include a critical experiment facility, a graphite pile, and a modular high-energy X-ray source (or accelerator facility). The proximity of these new facilities to UTK's football stadium brings heightened attention to their design and safety. An important aspect of this specific design is that shielding is required to contain the new radiation sources. The work completed will reflect the specific project planning and novel two-story facility design of the modular high-energy X-ray source. It will also provide a detailed shielding and dose analysis of the facility as a whole. The end design places an accelerator into a well-shielded room; it will then direct the x-ray beam through a collimating hole in the shielding wall into the next room. The x-ray beam is to be used as a part of a materials irradiation and imaging laboratory in the adjoining room. The design satisfies all regulatory requirements, and it will serve as the preliminary facility layout design and shielding analysis for a novel two-story modular high energy X-ray source facility. The dose rates calculated by the Monte Carlo models using the NCRP shielding thickness values are well below the dose limitations set by the State of Tennessee, which leaves room for optimization. Further work could be done to complete the optimization by reducing the shielding thickness while maintaining a dose below dose regulations by using a less conservative method for calculating the initial thicknesses. (authors)

43 PARTICLE ACCELERATORS↗

Ability to Simulate Absorption and Melt Pool Dynamics for Laser Melting of Bare Aluminum Plate: Results and Insights from the 2022 Asynchronous AM-Bench Challenge

The 2022 Asynchronous AM-Bench challenge was designed to test the ability of simulations to accurately predict laser power absorption as well as various melt pool behaviors (width, depth, and solidification) during laser melting of solid metal during stationary and scanned laser illumination. In this challenge, participants were asked to predict a series of experimental outcomes. Experimental data were obtained from a series of experiments performed at the Advanced Photon Source at Argonne National Laboratories in 2019. These experiments combined integrating sphere radiometry with high-speed X-ray imaging, allowing for the simultaneous recording of absolute laser power absorption and two-dimensional, projected images of the melt pool. All challenge problems were based on experiments using bare aluminum solid metal. Participants were provided with pertinent experimental information like laser power, scan speed, laser spot size, and material composition. Additionally, participants were given absorptance and X-ray imaging data from stationary and scanned laser experiments on solid Ti–6Al–4V that could be used for testing their models before attempting challenge problems. In total, this challenge received 56 submissions from eight different research groups for eight individual challenge problems. The data for this challenge, and associated information, are available for download from the NIST Public Data Repository. This paper summarizes the results from the 2022 Asynchronous AM-Bench challenge as well as discusses the lessons learned to help inform future challenges.

36 MATERIALS SCIENCE↗

Atomic data for astrophysics. Calculations, benchmarking and distribution

Some recent R-matrix and distorted-wave calculations, done as part of the UK APAPNetwork, are presented. They are focused on some ions important for the EUV and the X-rays, in particular for the solar corona. A long-term and novel project to benchmark atomic data against laboratory and astrophysical data is summarised, highlighting new plasma diagnostics. The various ways in which the atomic data are made available to the various communities through e.g. the CHIANTI and the VAMDC EU framework are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In-situ x-ray scatter imaging of battery electrodes

A method and apparatus for in-situ x-ray scatter imaging of battery electrodes. An apparatus includes an X-ray source, a grid, the grid comprising stainless steel wires with uniform spacing, and a cell, the X-ray source directing a beam of energy through the metal grid and components of the cell, the cell blurring a previously sharp projection of grid wires on an image detector. A method includes providing a Spatial Frequency Heterodyne Imaging system, providing a grid, providing a cell, generating X-rays from the Spatial Frequency Heterodyne Imaging system that pass through components of the cell and the grid, and detecting a scatter image from the X-rays.

Rose-Petruck, Christoph↗

X-Ray Backscatter Machine Support Frame

This summer at Kennedy Space Center, I spent 10 weeks as an intern working at the Prototype Development Lab. During this time I learned about the design and machining done here at NASA. I became familiar with the process from where a design begins in Pro/Engineer and finishes at the hands of the machinists. As an intern I was given various small jobs to do and then one project of my own. My personal project was a job for the Applied Physics Lab; in their work they use an X-Ray Backscatter machine. Previously it was resting atop a temporary frame that limited the use of the machine. My job was to design a frame for the machine to rest upon that would allow a full range of sample sizes. The frame was required to support the machine and provide a strain relief for the cords attached to the machine as it moved in the x and y directions. Calculations also had to be done to be sure the design would be able to withstand any loads or outside sources of stress. After the calculations proved the design to be ready to withstand the requirements, the parts were ordered or fabricated, as required. This helped me understand the full process of jobs sent to the Prototype Development Lab.

Cannon, Brooke↗

Underground muons from the direction of Cygnus X-3

The flux of underground muons from the direction of the binary Cygnus X-3 was measured by the Soudan 2 proton decay detector. This time-projection calorimeter is located at a depth of 2200 m (water equivalent) in northern Minnesota at latitude 48 deg N, longitude 92 deg W. An analysis was then performed that compared both the total observed flux and the observed flux per transit with the number of events expected in the absence of a source. This expected number of events was determined by combining the detector acceptance as a function of time with detector acceptance as a function of the local spatial coordinates. These functions were evaluated by use of off-source events. The direction of Cygnus X-3 was defined as a 2 deg half-angle cone, centered on the nominal source coordinates. This definition is consistent with the expected appearance of a point source in the Soudan 2 detector after consideration of track reconstruction errors, multiple scattering in the rock, and possible systematic effects. Details of the analysis and the results are presented.

Marshak, M. L.↗

Dedicated breast CT: radiation dose for circle-plus-line trajectory

Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD{sub g}N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD{sub g}N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD{sub g}N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2{pi} for the circular scan, the addition of a line trajectory with equal source spacing and constant x-ray beam quality (kVp and HVL) and mAs matched to the circular scan, will result in less than 0.18% increase in average glandular dose to the breast per projection along the line scan.

61 RADIATION PROTECTION AND DOSIMETRY↗

THE AFTERGLOW AND ULIRG HOST GALAXY OF THE DARK SHORT GRB 120804A

We present the optical discovery and subarcsecond optical and X-ray localization of the afterglow of the short GRB 120804A, as well as optical, near-IR, and radio detections of its host galaxy. X-ray observations with Swift/XRT, Chandra, and XMM-Newton extending to {delta}t Almost-Equal-To 19 days reveal a single power-law decline. The optical afterglow is faint, and comparison to the X-ray flux indicates that GRB 120804A is ''dark'', with a rest-frame extinction of A {sup host}{sub V} Almost-Equal-To 2.5 mag (at z = 1.3). The intrinsic neutral hydrogen column density inferred from the X-ray spectrum, N{sub H,{sub int}}(z = 1.3) Almost-Equal-To 2 Multiplication-Sign 10{sup 22} cm{sup -2}, is commensurate with the large extinction. The host galaxy exhibits red optical/near-IR colors. Equally important, JVLA observations at Almost-Equal-To 0.9-11 days reveal a constant flux density of F{sub {nu}}(5.8 GHz) = 35 {+-} 4 {mu}Jy and an optically thin spectrum, unprecedented for GRB afterglows, but suggestive instead of emission from the host galaxy. The optical/near-IR and radio fluxes are well fit with the scaled spectral energy distribution of the local ultraluminous infrared galaxy (ULIRG) Arp 220 at z Almost-Equal-To 1.3, with a resulting star formation rate of x Almost-Equal-To 300 M{sub Sun} yr{sup -1}. The inferred extinction and small projected offset (2.2 {+-} 1.2 kpc) are also consistent with the ULIRG scenario, as is the presence of a companion galaxy at the same redshift and with a separation of about 11 kpc. The limits on radio afterglow emission, in conjunction with the observed X-ray and optical emission, require a circumburst density of n {approx} 10{sup -3} cm{sup -3}, an isotropic-equivalent energy scale of E{sub {gamma},{sub iso}} Almost-Equal-To E{sub K,{sub iso}} Almost-Equal-To 7 Multiplication-Sign 10{sup 51} erg, and a jet opening angle of {theta}{sub j} {approx}> 11 Degree-Sign . The expected fraction of luminous infrared galaxies in the short GRB host sample is {approx}0.01 and {approx}0.25 (for pure stellar mass and star formation weighting, respectively). Thus, the observed fraction of two events in about 25 hosts (GRBs 120804A and 100206A) appears to support our previous conclusion that short GRBs track both stellar mass and star formation activity.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic data of tungsten for current and future uses in fusion and plasma science

Atomic physics has played an important role throughout the history of experimental plasma physics. For example, accurate knowledge of atomic properties has been crucial for understanding the plasma energy balance and for diagnostic development. With the shift in magnetic fusion research toward high-temperature burning plasmas like those expected to be produced in the ITER tokamak, the atomic physics of tungsten has become important. Tungsten will be a constituent of ITER plasmas because of its use as a plasma-facing material able to withstand high heat loads with lower tritium retention than other possible materials. Already, ITER diagnostics are being developed based on using tungsten radiation. In particular, the ITER Core Imaging X-ray Spectrometer (CIXS), which is designed to measure the core ion temperature and bulk plasma motion, is being based on the x-ray emission of neonlike tungsten ions (W{sup 64+}). In addition, tungsten emission will at ITER be measured by extreme ultraviolet (EUV) and optical spectrometers to determine its concentration in the plasma and to assess power loss and tungsten sputtering rates. On present-day tokamaks tungsten measurements are therefore being performed in preparation of ITER. Tungsten has very complex spectra and most are still unknown. The WOLFRAM project at Livermore aims to produce data for tungsten in various spectral bands: Lshell x-ray emission for CIXS development, soft x-ray and EUV M- and N-shell tungsten emission for understanding the edge radiation from ITER plasmas as well as from contemporary tokamaks, and O-shell emission for developing spectral diagnostics of the ITER divertor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional reconstruction of neutron, gamma-ray, and x-ray sources using spherical harmonic decomposition

Neutron, gamma-ray, and x-ray imaging are important diagnostic tools at the National Ignition Facility (NIF) for measuring the two-dimensional (2D) size and shape of the neutron producing region, for probing the remaining ablator and measuring the extent of the DT plasmas during the stagnation phase of Inertial Confinement Fusion implosions. Due to the difficulty and expense of building these imagers, at most only a few two-dimensional projections images will be available to reconstruct the three-dimensional (3D) sources. In this work, we present a technique that has been developed for the 3D reconstruction of neutron, gamma-ray, and x-ray sources from a minimal number of 2D projections using spherical harmonics decomposition. We present the detailed algorithms used for this characterization and the results of reconstructed sources from experimental neutron and x-ray data collected at OMEGA and NIF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

X-ray emission from a complete sample of Abell clusters of galaxies

The Rosat all sky survey is used to investigate the X-ray properties of a sample of Abell clusters with measured redshifts and accurate positions. The sample comprises the 145 clusters within a 561 square degree region at high galactic latitude. The mean redshift is 0.17. The sample mean exposure time is higher than average and its mean galactic column density is very low. These together produce a flux limit of about 4.2 x 10(exp -13) erg/sq cm/s in the 0.5 to 2.5 keV energy band. By analyzing the excess of positive fluctuations of the X-ray flux at the cluster positions, compared with the fluctuations of randomly drawn background fields, it is possible to extend these results below the nominal flux limit. It is found that 80 of richness R equal to or greater than 0 and 86 of R equal to or greater than 1 clusters are X-ray emitters with fluxes above 1.10 to the power of minus 13 erg/sq cm/s. Nearly 90 of the clusters meeting the requirements to be in Abell's statistical sample emit above the same level. It is concluded that almost all Abell clusters are real clusters and the Abell catalogue is not strongly contaminated by projection effects. The Kaplan-Meier product limit estimator is used to calculate the cumulative X-ray luminosity function. It is shown that the shape of the luminosity functions are similar for different richness classes, but the characteristic luminosities of richness 2 clusters are about twice of those of richness 1 clusters which are in turn about twice of those of richness zero clusters. This result is another manifestation of the luminosity richness relation for Abell cluster.

Briel, Ulrich G.↗