Search NASA⌕ Search

SEARCH · Search NASA

Results for “Pulse generators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Characterization of a Pulse Neutron Source Yield under Field Conditions

Technique of rapid evaluation of a pulse neutron sources such as neutron generators under field conditions has been developed. The phoswich sensor and pulse-shape discrimination techniques have been used for the simultaneous measurements of fast neutrons, thermal neutrons, and photons. The sensor has been calibrated using activation neutron detectors and a pulse deuterium-tritium fusion neutron source.

43 PARTICLE ACCELERATORS↗

Generation of straight and curved hollow plasma channels by laser-generated nonlinear wakefields and studies of ultra-intense laser pulse guiding

We report on a study of highly controllable, quasi-static hollow plasma channels generated by ion motion following a laser–plasma interaction via numerical simulations. These channels are generated by ion motion in a nonlinear wakefield, which has an asymmetry between focusing and defocusing periods. Such plasma channels, driven by a fs duration, 100 TW level laser pulse, have the capability to guide more powerful laser pulses. Moreover, we show that curved plasma channels can be generated in a transverse density gradient plasma and alloptical guiding of a second, significantly more powerful laser pulse in such a curved plasma channel. This mechanism may be useful for creating plasma optics for multi-stage TeV laser plasma accelerators and compact synchrotron radiation sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High Energy Output Marx Generator Design

High Energy Output Marx Generator Design a design of a six stage Marx generator that has a unipolar pulse waveform of 200 kA in a 50×500 microsecond waveform is presented. The difficulties encountered in designing the components to withstand the temperatures and pressures generated during the output pulse are discussed. The unique methods and materials used to successfully overcome these problems are given. The steps necessary to increase the current output of this Marx generator design to the meg-ampere region or higher are specified.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Topographic controls on a phreatomagmatic maar-diatreme eruption: field and numerical results from the Holocene Dotsero volcano (Colorado, USA)

We analyzed the eruptive products of Holocene Dotsero volcano (Colorado, USA; ~4.15 ka), which recorded evidence of a progression from effusive magmatic activity through explosive phreatomagmatic maar-forming activity to a final explosive magmatic phase. The nature of the deposits suggests that the irregular and mountainous pre-eruptive topography strongly influenced the formation of directed pyroclastic density currents (PDCs) during the phreatomagmatic phase, where the topographically high northern crater rim acted as a barrier and promoted transport to the south. Furthermore, the crater shape strongly controlled the grain size of the final deposits, providing further evidence that deposit grain size can be a misleading proxy for fragmentation or explosion intensity. We test these hypotheses, as gleaned from fieldwork, by implementing a multiphase numerical model to simulate discrete explosions and their resulting PDCs at maar-diatreme volcanoes. We confirm that a crater shape where one rim is higher than the other promotes multiple pulses of particle transport in the direction of the lower rim. The initial PDCs contain both coarse and fine particles, whereas PDCs generated by later pulses contain, predominately, finer particles. This mechanism provides an alternative explanation to the formation of lapilli tuff/tuff couplets often found at maar-diatreme tephra rings (including Dotsero volcano). Additional modeling shows how the crater depth can control grain size of the resulting PDC deposits. In the case of a deep crater and a relatively weak explosion, it is possible that only the fine particles escape following collapse of the eruptive column, resulting in a fine-grained deposit. This work allows us to improve models developed to describe emplacement of PDCs for different crater geometries and informs on the dynamics of maar-diatreme eruptions, but also highlights the limitations of our knowledge of key parameters, especially those related to the processes of magma-water interaction and syn-eruptive hydrogeology, during such events.

58 GEOSCIENCES↗

Demonstration of a compact, multi-joule, diode-pumped Tm:YLF laser

We report the demonstration of a diode-pumped Tm:YLF laser operating at 1.88 µm that produces pulse energies up to 3.88 J in 20 ns. The compact system consists of a Q-switched cavity-dumped oscillator generating 18 mJ pulses, which are then amplified in a 4-pass power amplifier. Energies up to 38.1 J were obtained with long-pulse amplifier operation. These results illustrate the high energy storage and extraction capabilities of diode-pumped Tm:YLF, opening the path to high peak and average power mid-infrared solid-state lasers

47 OTHER INSTRUMENTATION↗

Super-octave longwave mid-infrared coherent transients produced by optical rectification of few-cycle 25-μm pulses

Femtosecond laser sources and optical frequency combs in the molecular fingerprint region of the electromagnetic spectrum are crucial for a plethora of applications in natural and life sciences. Here we introduce Cr 2+ -based lasers as a convenient means for producing super-octave mid-IR electromagnetic transients via optical rectification (or intra-pulse difference frequency generation, IDFG). We demonstrate that a relatively long, 2.5 μm, central wavelength of a few-cycle Cr 2+ :ZnS driving source (20 fs pulse duration, 6 W average power, 78 MHz repetition rate) enabled the use of highly nonlinear ZnGeP 2 crystal for IDFG with exceptionally high conversion efficiency (>3%) and output power of 0.15 W, with the spectral span of 5.8–12.5 μm. Even broader spectrum was achieved in GaSe crystal: 4.3–16.6 μm for type I and 5.8–17.6 μm for type II phase matching. The results highlight the potential of this architecture for ultrafast spectroscopy and generation of broadband frequency combs in the longwave infrared.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Angular Distributions of Plasma Flows in a Vacuum Arc with Boride Cathodes

Results of investigation of the angular distribution and mass-to-charge fractions of the ion flow generated in a pulsed vacuum arc with lanthanum hexaboride and boron carbide cathodes are presented. It is shown that the discharge with such cathodes provides efficient generation of the plasma with a high fraction of boron ions with charge states from 1+ to 3+ whose total fraction is determined by the fraction of the boron atoms in the cathode material. The angular distributions of ions in the plasma flow depend on the relationship between the masses of components of cathode materials: in the case of lanthanum hexaboride cathode, the distribution of boron ions is wider than that of lanthanum ions, and in the case of boron carbide cathode, the boron and carbon ion distributions are practically identical.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct probing of electronic density distribution of a Rydberg state by high-order harmonic generation in a few-cycle laser pulse

We demonstrate that the electronic density distribution of a Rydberg state can be probed directly using a broadband harmonic spectrum in a few-cycle laser pulse. Taking advantage of the large orbital radius of a Rydberg state, we show that the Rydberg electron can be accelerated directly toward the core under the influence of a few-cycle laser pulse, leading to recombination and emission of harmonic photons. In this case the initial position of the electron and the harmonic order form a one-to-one correspondence, resulting in a realization of direct probing of the density distribution of the initial Rydberg state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Transport of time-varying plasma currents by whistler wave packets

The relationship between pulsed currents and electromagnetic waves is examined in a regime characterized by electron MHD. Pulsed currents are generated by (1) collection/emission of charged particles by/from biased electrodes and (2) induction of currents by time-varying and moving magnetic fields. Pulsed currents are observed to propagate at the speed of whistler wave packets. Their field structure forms ropelike configurations which are electromagnetically force-free. Moving sources induce 'eddy' currents which excite waves and form Cerenkov-like whistler 'wings'. The radiation patterns of moving magnetic antennas and electrodynamic tethers are investigated. Nonlinear effects of large-amplitude, antenna-launched whistler pulses are observed. These involve a new modulational instability in which a channel of high conductivity which permits the wave/currents to penetrate deeply into a collisional plasma is formed.

Stenzel, R. L.↗

A long-pulse repetitive operation magnetically insulated transmission line oscillator

The improved magnetically insulated transmission line oscillator (MILO) is a gigawatt-class L-band high power microwave tube. It has allowed us to generate 3.1 GW pulse of 40 ns duration in the single-pulse operation and 500 MW pulse of 25 ns duration in the repetition rate operation. However, because of the severe impedance mismatch, the power conversion efficiency is only about 4% in the repetition rate operation. In order to eliminate the impedance mismatch and obtain repetitive long-pulse high-power microwave (HPM), a series of experiments are carried out and the recent progress is presented in this paper. In the single-pulse operation, when the diode voltage is 466 kV and current is 41.6 kA, the radiated microwave power is above 2.2 GW, the pulse duration is above 102 ns, the microwave frequency is about 1.74 GHz, and the power conversion efficiency is about 11.5%. In the repetition rate operation, under the condition of the diode voltage about 400 kV, beam current about 38 kA, the radiated microwave power is about 1.0 GW, the pulse duration is about 85 ns. Moreover, the radiated microwave power and the pulse duration decline little by little when the shot numbers increase gradually. The experimental results show that the impedance matching is a vital factor for HPM systems and one of the major technical challenges is to improve the cathode for the repetition rate operation MILO.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear XUV signal generation probed by transient grating spectroscopy with attosecond pulses

Nonlinear spectroscopies are utilized extensively for selective measurements of chemical dynamics in the optical, infrared, and radio-frequency regimes. The development of these techniques for extreme ultraviolet (XUV) light sources facilitates measurements of electronic dynamics on attosecond timescales. Here, we elucidate the temporal dynamics of nonlinear signal generation by utilizing a transient grating scheme with a subfemtosecond XUV pulse train and two few-cycle near-infrared pulses in atomic helium. Simultaneous detection of multiple diffraction orders reveals delays of ≥1.5 fs in higher-order XUV signal generation, which are reproduced theoretically by solving the coupled Maxwell-Schrödinger equations and with a phase grating model. The delays result in measurable order-dependent differences in the energies of transient light induced states. As nonlinear methods are extended into the attosecond regime, the observed higher-order signal generation delays will significantly impact and aid temporal and spectral measurements of dynamic processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Generation of strong magnetic fields for magnetized plasma experiments at the 1-MA pulsed power machine

Pulsed power technology provides a platform for investigating plasmas in strong magnetic fields using a university-scale machine. Presented here are methods for generating and measuring the 1–4-MG magnetic fields developed for the 1-MA Zebra pulsed power generator at the University of Nevada, Reno. A laser coupled with the Zebra generator produces a magnetized plasma, and experiments investigate how a megagauss magnetic field affects the two-plasmon decay and the expansion of the laser-produced plasma in both transverse and longitudinal magnetic fields.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Rapid RASER MRI

Conventional Magnetic Resonance Imaging (MRI) relies on high-power Radio-Frequency (RF) pulses to excite nuclear spins and in turn generate NMR signals. These pulses require large high-power RF-amplifiers and cause heat deposition in the tissue, which must be minimized for safety, presenting a growing problem when moving toward ever-higher field MRI. An alternative to RF-pulse excitation is self-excitation of nuclear spins using Radiofrequency Amplification by Stimulated Emission of Radiation (RASER), where the nuclear spins undergo spontaneous transition, without RF excitation, from an over-populated state to a ground state. Here, the feasibility of recording rapid proton RASER MRI images of pyrazine at low concentration (120 mM) with large matrix (128x128 pixels) in as little as 78 ms is demonstrated at 500 MHz (11.7 T). We also recorded a time-series of images using a single bolus hyperpolarized pyrazine highlighting the feasibility of dynamic tracking. Here, the demonstrated approach allows recording MRI scans without transmit-receive electronics of the MRI scanner, which is highly desirable for portable MRI as well as the emerging field of hyperpolarized MRI using, e.g., HP protons, 129 Xe gas or HP 13 C labeled biomolecules as molecular tracers and imaging agents.

MRI↗

A reliable, compact, and repetitive-rate high power microwave generation system

A compact high power microwave (HPM) generation system is described in this paper. The main parts of the HPM system are a Marx generator with a pulse forming line and a magnetron with diffraction output. The total weight and length of the system are 250 kg and 120 cm, respectively. The output microwave power of the HPM system at 550 kV of applied voltage and 0.33 T of magnetic field reaches 1 GW at 2.32 GHz of central frequency with 38 ns of pulse duration, 23% of power conversion efficiency, and Gaussian radiation pattern. In the bursts operation, both time and amplitude jitters are less than 4 ns and lower than 1.5 dB, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1.1 J Yb:YAG picosecond laser at 1 kHz repetition rate

We demonstrate the generation of 1.1 J pulses of picosecond duration at 1 kHz repetition rate (1.1 kW average power) from a diode-pumped chirped pulse amplification Yb:YAG laser. The laser employs cryogenically cooled amplifiers to generate λ <#comment/> = 1030 n m pulses with average power of up to 1.26 kW prior to compression with excellent beam quality. Pulses are compressed to 4.5 ps duration with 90% efficiency. This compact picosecond laser will enable a variety of applications that require high energy ultrashort pulses at kilohertz repetition rates.

Wang, Yong↗

New acousto-ultrasonic techniques applied to aerospace materials

The use of an NdYAG pulsed laser for generating ultrasonic waves for NDE in resin matrix composites was investigated. A study was conducted of the use of the 1.064 micron wavelength NdYAG pulsed laser with the neat, unreinforced resin as well as graphite fiber/polymer composite specimens. In the case of the neat resins it was found that, at normal incidence, about 25 percent of the laser pulse energy was reflected at the incident surface. An attenuation coefficient for the polyimide resin, PMR-15 was determined to be approximately 5.8 np/cm. It was found in energy balance studies that graphite fiber/polymer specimens attenuate the laser beam more than do neat resins. The increase absorption is in the graphite fibers. The occurrence of laser induced surface damage was also studied. For the polymer neat resin, damage appears as pit formation over a small fraction of the pulse impact area and discoloration over a larger part of the area. A damage threshold was inferred from observed damage as a function of pulse energy. The 600 F cured PMR-15 and PMR-11 exhibit about the same amount of damage for a given laser pulse energy. The damage threshold is between 0.06 and 0.07 J/sq cm.

Kautz, Harold E.↗