Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Comparison of Solar UVA and UVB Radiation Measured in Selangor, Malaysia

The solar ultraviolet A (UVA) radiation data was measured at Physics Building, Universiti Kebangsaan Malaysia (2 degree sign 55' N, 101 degree sign 46' E, 50m asl) by the Xplorer GLX Pasco that connected to UVA Light sensor. The measured solar UVA data were compared with the total daily solar ultraviolet B (UVB) radiation data recorded by the Malaysian Metrological Department at Petaling Jaya, Malaysia (3 degree sign 06' N, 101 degree sign 39' E, 50m asl) for 18 days in year 2007. The daily total average of UVA radiation received is (298{+-}105) kJm{sup -2} while the total daily maximum is (600{+-}56) kJm{sup -2}. From the analysis, it shows that the values of UVA radiation data were higher than UVB radiation data with the average ratio of 6.41% between 3-14%. A weak positive correlation was found (the correlation coefficient, r, is 0.22). The amount of UVA radiation that reached the earth surface is less dependence on UVB radiation and the factors were discussed.

54 ENVIRONMENTAL SCIENCES↗

General description of electromagnetic radiation processes based on instantaneous charge acceleration in ''endpoints''

We present a methodology for calculating the electromagnetic radiation from accelerated charged particles. Our formulation - the 'endpoint formulation' - combines numerous results developed in the literature in relation to radiation arising from particle acceleration using a complete, and completely general, treatment. We do this by describing particle motion via a series of discrete, instantaneous acceleration events, or 'endpoints', with each such event being treated as a source of emission. This method implicitly allows for particle creation and destruction, and is suited to direct numerical implementation in either the time or frequency domains. In this paper we demonstrate the complete generality of our method for calculating the radiated field from charged particle acceleration, and show how it reduces to the classical named radiation processes such as synchrotron, Tamm's description of Vavilov-Cherenkov, and transition radiation under appropriate limits. Using this formulation, we are immediately able to answer outstanding questions regarding the phenomenology of radio emission from ultra-high-energy particle interactions in both the earth's atmosphere and the moon. In particular, our formulation makes it apparent that the dominant emission component of the Askaryan effect (coherent radio-wave radiation from high-energy particle cascades in dense media) comes from coherent 'bremsstrahlung' from particle acceleration, rather than coherent Vavilov-Cherenkov radiation.

43 PARTICLE ACCELERATORS↗

Patient radiation doses in interventional cardiology in the U.S.: Advisory data sets and possible initial values for U.S. reference levels

Purpose: To determine patient radiation doses from interventional cardiology procedures in the U.S and to suggest possible initial values for U.S. benchmarks for patient radiation dose from selected interventional cardiology procedures [fluoroscopically guided diagnostic cardiac catheterization and percutaneous coronary intervention (PCI)]. Methods: Patient radiation dose metrics were derived from analysis of data from the 2008 to 2009 Nationwide Evaluation of X-ray Trends (NEXT) survey of cardiac catheterization. This analysis used deidentified data and did not require review by an IRB. Data from 171 facilities in 30 states were analyzed. The distributions (percentiles) of radiation dose metrics were determined for diagnostic cardiac catheterizations, PCI, and combined diagnostic and PCI procedures. Confidence intervals for these dose distributions were determined using bootstrap resampling. Results: Percentile distributions (advisory data sets) and possible preliminary U.S. reference levels (based on the 75th percentile of the dose distributions) are provided for cumulative air kerma at the reference point (K{sub a,r}), cumulative air kerma-area product (P{sub KA}), fluoroscopy time, and number of cine runs. Dose distributions are sufficiently detailed to permit dose audits as described in National Council on Radiation Protection and Measurements Report No. 168. Fluoroscopy times are consistent with those observed in European studies, but P{sub KA} is higher in the U.S. Conclusions: Sufficient data exist to suggest possible initial benchmarks for patient radiation dose for certain interventional cardiology procedures in the U.S. Our data suggest that patient radiation dose in these procedures is not optimized in U.S. practice.

07 ISOTOPE AND RADIATION SOURCES↗

Beta Androstenediol Mitigates the Damage of 1 GeV/n Fe Ion Particle Radiation to the Hematopoietic System

Space exploration is associated with exposure to 1-3 Gy solar particle radiation and galactic cosmic radiation that could increase cancer rates. Effective nontoxic countermeasures to high linear energy transfer (LET) radiation exposure are highly desirable but currently not available. The aim was to determine whether a single subcutaneous injection of androstenediol ({Delta}(5) androsten-3{beta}, 17{beta}-diol [AED]) could mitigate and restore the mouse hematopoetic system from the radiation-mediated injury of 3 Gy whole-body high LET (56)Fe(26+) exposure. The findings show that postradiation AED treatment has an overall positive and significant beneficial effect to restore the levels of hematopoeitic elements (p < 0.001). Androstenediol treatment significantly increased monocyte levels at days 4, 7, and 14 and, similarly, increased red blood cell, hemoglobin, and platelet counts. Flow cytometry analysis 14 days after radiation and AED treatment demonstrated an increase (p < 0.05) in bone marrow cells counts. Ex vivo osteoclastogenesis studies show that AED treatment is necessary and advantageous for the development and restoration of osteoclastogenesis after radiation exposure. These findings clearly show that androstenediol functions as a countermeasure to remedy hematopoeitic injury mediated by high LET iron ion radiation. Presently, no other agent has been shown to have such properties.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Exposure to Ionizing Radiation Causes Long-Term Increase in Serum Estradiol and Activation of PI3K-Akt Signaling Pathway in Mouse Mammary Gland

Purpose: Exposure to ionizing radiation is an established risk factor for breast cancer. Radiation exposure during infancy, childhood, and adolescence confers the highest risk. Although radiation is a proven mammary carcinogen, it remains unclear where it acts in the complex multistage process of breast cancer development. In this study, we investigated the long-term pathophysiologic effects of ionizing radiation at a dose (2 Gy) relevant to fractionated radiotherapy. Methods and Materials: Adolescent (6-8 weeks old; n = 10) female C57BL/6J mice were exposed to 2 Gy total body {gamma}-radiation, the mammary glands were surgically removed, and serum and urine samples were collected 2 and 12 months after exposure. Molecular pathways involving estrogen receptor-{alpha} (ER{alpha}) and phosphatidylinositol-3-OH kinase (PI3K)-Akt signaling were investigated by immunohistochemistry and Western blot. Results: Serum estrogen and urinary levels of the oncogenic estrogen metabolite (16{alpha}OHE1) were significantly increased in irradiated animals. Immunostaining for the cellular proliferative marker Ki-67 and cyclin-D1 showed increased nuclear accumulation in sections of mammary glands from irradiated vs. control mice. Marked increase in p85{alpha}, a regulatory sub-unit of the PI3K was associated with increase in Akt, phospho-Akt, phospho-BAD, phospho-mTOR, and c-Myc in irradiated samples. Persistent increase in nuclear ER{alpha} in mammary tissues 2 and 12 months after radiation exposure was also observed. Conclusions: Taken together, our data not only support epidemiologic observations associating radiation and breast cancer but also, specify molecular events that could be involved in radiation-induced breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Size and the Risk of Radiation Pneumonitis

Purpose: The purpose of this study was to identify patient populations treated for non-small cell lung cancer (NSCLC) who may be more at risk of radiation pneumonitis. Methods and Materials: A total of 579 patients receiving fractionated 3D conformal or intensity modulated radiation therapy (IMRT) for NSCLC were included in the study. Statistical analysis was performed to search for cohorts of patients with higher incidences of radiation pneumonitis. In addition to conventional risk factors, total and spared lung volumes were analyzed. The Lyman-Kutcher-Burman (LKB) and cure models were then used to fit the incidence of radiation pneumonitis as a function of lung dose and other factors. Results: Total lung volumes with a sparing of less than 1854 cc at 40 Gy were associated with a significantly higher incidence of radiation pneumonitis at 6 months (38% vs 12% for patients with larger volumes, P<.001). This patient cohort was overwhelmingly female and represented 22% of the total female population of patients and nearly 30% of the cases of radiation pneumonitis. An LKB fit to normal tissue complication probability (NTCP) including volume as a dose modifying factor resulted in a dose that results in a 50% probability of complication for the smaller spared volume cohort that was 9 Gy lower than the fit to all mean lung dose data and improved the ability to predict radiation pneumonitis (P<.001). Using an effective dose parameter of n=0.42 instead of mean lung dose further improved the LKB fit. Fits to the data using the cure model produced similar results. Conclusions: Spared lung volume should be considered when treating NSCLC patients. Separate dose constraints based on smaller spared lung volume should be considered. Smaller spared lung volume patients should be followed closely for signs of radiation pneumonitis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Dose Escalation in Esophageal Cancer Revisited: A Contemporary Analysis of the National Cancer Data Base, 2004 to 2012

Purpose: To evaluate the effect of radiation dose escalation on overall survival (OS) for patients with nonmetastatic esophageal cancer treated with concurrent radiation and chemotherapy. Methods and Materials: Patients diagnosed with stage I to III esophageal cancer treated from 2004 to 2012 were identified from the National Cancer Data Base. Patients who received concurrent radiation and chemotherapy with radiation doses of ≥50 Gy and did not undergo surgery were included. OS was compared using Cox proportional hazards regression and propensity score matching. Results: A total of 6854 patients were included; 3821 (55.7%) received 50 to 50.4 Gy and 3033 (44.3%) received doses >50.4 Gy. Univariate analysis revealed no significant difference in OS between patients receiving 50 to 50.4 Gy and those receiving >50.4 Gy (P=.53). The dose analysis, binned as 50 to 50.4, 51 to 54, 55 to 60, and >60 Gy, revealed no appreciable difference in OS within any group compared with 50 to 50.4 Gy. Subgroup analyses investigating the effect of dose escalation by histologic type and in the setting of intensity modulated radiation therapy also failed to reveal a benefit. Propensity score matching confirmed the absence of a statistically significant difference in OS among the dose levels. The factors associated with improved OS on multivariable analysis included female sex, lower Charlson-Deyo comorbidity score, private insurance, cervical/upper esophagus location, squamous cell histologic type, lower T stage, and node-negative status (P<.01 for all analyses). Conclusions: In this large national cohort, dose escalation >50.4 Gy did not result in improved OS among patients with stage I to III esophageal cancer treated with definitive concurrent radiation and chemotherapy. These data suggest that despite advanced contemporary treatment techniques, OS for patients with esophageal cancer remains unaltered by escalation of radiation dose >50.4 Gy, consistent with the results of the INT-0123 trial. Furthermore, these data highlight that many radiation oncologists have not embraced the concept that dose escalation does not improve OS. Although local control, not investigated in the present study, might benefit from dose escalation, novel therapies are needed to improve the OS of patients with esophageal cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Contextually aware roadside radiation measurement testbed

Here we demonstrate a contextually aware multimodal roadside radiation measurement detection testbed for traffic monitoring applications in nuclear nonproliferation. Many variables in traffic such as vehicle or cargo size, mass, speed, shape, and distance of closest approach can have significant impacts on the radiation measured from a vehicle-transported radiation source. These factors can lead to uncertainties in the analysis of the radiation source, especially for lower-strength radiation sources of interest. Our testbed, known as the Multimodal Measurement System (MMS) uses non-radiation sensors including magnetometers, geophones, radiofrequency receivers, cameras, and LiDAR to extract contextual information about vehicles passing by the system. These contextual data can then be fused with data from radiation measurements to increase the system’s sensitivity and accuracy in nuclear threat detection applications. This work describes the instrumentation of the MMS and its data acquisition pipeline. Furthermore, we describe the pre-analysis performed on the raw multimodal data streams for data fusion, and the high-level machine learning analyses for detection and characterization. The variety of sensors within the MMS provides a valuable testbed that can be used to identify the combinations of contextual sensors that provide the greatest improvements to radiation source detection and characterization within the restrictions for various proliferation detection applications. The MMS is also modular so that additional combinations of sensors can be explored in the future.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Endothelial surface translocation of mitochondrial PDCE2 involves the non-canonical secretory autophagy pathway: Putative molecular target for radiation-guided drug delivery

Highlights: • Radiation induces ectopic endothelial surface exposure of mitochondrial PDCE2. • PDCE2 translocation is associated with late-stage inhibition of autophagic flux. • Radiation damage overloads the degradative lysosomal pathway of autophagy. • PDCE2 trafficking occurs via autophagosomes and non-canonical secretory autophagy. • Surface PDCE2 provides a novel target for radiation-guided vascular drug delivery. Radiation has been proposed as a priming agent to induce discriminatory luminal biomarkers for vascular targeting and drug delivery in disorders such as brain arteriovenous malformations and cancers. We previously observed ectopic expression of intracellular proteins such as mitochondrial PDCE2 on irradiated endothelium in animal models. In this study we examined the mechanism of PDCE2 trafficking in human endothelial cells to better understand its suitability as a vascular target. Ionizing radiation induced PDCE2 surface localization in association with accumulation of autophagosome markers (L3CB and p62) indicative of late-stage inhibition of autophagic flux. This effect was abolished in the presence of Rapamycin, an autophagy-inducer, but replicated in the presence of Bafilomycin A, an autophagy blocker. PDCE2 co-localized with lysosomal markers of the canonical degradative autophagy pathway in response to radiation but also with recycling endosomes and SNARE proteins responsible for autophagosome-plasma membrane fusion. These findings demonstrate that radiation-induced blockade of autophagic flux stimulates redirection of intracellular molecules such as PDCE2 to the cell surface via a non-canonical secretory autophagy pathway. Intracellular membrane proteins trafficked in this way could provide a unique pool of radiation biomarkers for therapeutic drug delivery.

60 APPLIED LIFE SCIENCES↗

Linker Contribution toward Stability of Metal–Organic Frameworks under Ionizing Radiation

Here, the effects of radiation on a series of UiO derivative metal–organic frameworks (MOFs) that contain the same zirconium hexamer node and similar organic linkers, UiO-66, UiO-66–NH 2 , UiO-66–OH, and NU-403, were examined using γ-rays and 5 MeV He ions. UiO-66, UiO-66–NH2, and UiO-66–OH contain aromatic linkers and are significantly more stable to radiation than NU-403. Of these, UiO-66 is the most radiation resistant, displaying crystalline features up to 47 MGy of He-ion irradiation. MOFs containing aromatic linkers functionalized by electron-donating groups, UiO-66–NH 2 and UiO-66–OH, retained crystalline features up to 19 MGy. NU-403 contains aliphatic rings and is the least radiation-resistant MOF studied here. NU-403 exhibits small changes in infrared spectra upon 3 MGy of γ-irradiation and significant damage upon 10 MGy of He-ion irradiation. Diffraction data revealed radiation-induced defect formation. Structural locations of radiation-induced breakdown were interrogated experimentally and via density functional theory. The results indicated changes in the carboxylate (-OCO) of the linker and μ 3 -OH vibrational modes, suggesting that introduction of an aliphatic linker into the MOF renders the connection between the linker and metal node most susceptible to radiation damage. This study reveals that the choice of the linker is crucial in designing a radiation-resistant MOF.

36 MATERIALS SCIENCE↗

Bounding Global Aerosol Radiative Forcing of Climate Change

Abstract Aerosols interact with radiation and clouds. Substantial progress made over the past 40 years in observing, understanding, and modeling these processes helped quantify the imbalance in the Earth's radiation budget caused by anthropogenic aerosols, called aerosol radiative forcing, but uncertainties remain large. This review provides a new range of aerosol radiative forcing over the industrial era based on multiple, traceable, and arguable lines of evidence, including modeling approaches, theoretical considerations, and observations. Improved understanding of aerosol absorption and the causes of trends in surface radiative fluxes constrain the forcing from aerosol‐radiation interactions. A robust theoretical foundation and convincing evidence constrain the forcing caused by aerosol‐driven increases in liquid cloud droplet number concentration. However, the influence of anthropogenic aerosols on cloud liquid water content and cloud fraction is less clear, and the influence on mixed‐phase and ice clouds remains poorly constrained. Observed changes in surface temperature and radiative fluxes provide additional constraints. These multiple lines of evidence lead to a 68% confidence interval for the total aerosol effective radiative forcing of ‐1.6 to ‐0.6 W m −2 , or ‐2.0 to ‐0.4 W m −2 with a 90% likelihood. Those intervals are of similar width to the last Intergovernmental Panel on Climate Change assessment but shifted toward more negative values. The uncertainty will narrow in the future by continuing to critically combine multiple lines of evidence, especially those addressing industrial‐era changes in aerosol sources and aerosol effects on liquid cloud amount and on ice clouds.

54 ENVIRONMENTAL SCIENCES↗

Simulation of nanosecond pulsed laser ablation of copper samples: A focus on laser induced plasma radiation

A thermal model for nanosecond pulsed laser ablation of Cu in one dimension and in ambient gas, He at 1 atm, is proposed in which equations concerning heat conduction in the target and gas dynamics in the plume are solved. These equations are coupled to each other through the energy and mass balances at interface between the target and the vapor and also Knudsen layer conditions. By assumption of local thermal equilibrium, Saha-Eggert equations are used to investigate plasma formation. The shielding effect of the plasma, due to photoionization and inverse bremsstrahlung processes, is considered. Bremsstrahlung and blackbody radiation and spectral emissions of the plasma are also investigated. Spatial and temporal distribution of the target temperature, number densities of Cu and He, pressure and temperature of the plume, bremsstrahlung and blackbody radiation, and also spectral emissions of Cu at three wavelengths (510, 516, and 521 nm) are obtained. Results show that the spectral power of Cu lines has the same pattern as CuI relative intensities from National Institute of Standard and Technology. Investigation of spatially integrated bremsstrahlung and blackbody radiation, and also Cu spectral emissions indicates that although in early times the bremsstrahlung radiation dominates the two other radiations, the Copper spectral emission is the dominant radiation in later times. It should be mentioned that the blackbody radiation has the least values in both time intervals. The results can be used for prediction of the optimum time and position of the spectral line emission, which is applicable in some time resolved spectroscopic techniques such as laser induced breakdown spectroscopy. Furthermore, the results suggest that for distinguishing between the spectral emission and the bremsstrahlung radiation, a spatially resolved spectroscopy can be used instead of the time resolved one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Radiation shielding properties of barite coated fabric by computer programme

With the development of technology radiation started to be used in variety of different fields. As the radiation is hazardous for human health, it is important to keep radiation dose as low as possible. This is done mainly using shielding materials. Barite is one of the important materials in this purpose. As the barite is not used directly it can be used in some other materials such as fabric. For this purposes barite has been coated on fabric in order to improve radiation shielding properties of fabric. Determination of radiation shielding properties of coated fabric has been done by using computer program written C# language. With this program the images obtained from digital Rontgen films is used to determine radiation shielding properties in terms of image processing numerical values. Those values define radiation shielding and in this way the coated barite effect on radiation shielding properties of fabric has been obtained.

07 ISOTOPE AND RADIATION SOURCES↗

ON THE JITTER RADIATION

In a small-scale turbulent medium, when the nonrelativistic Larmor radius R{sub L} = mc {sup 2}/eB exceeds the correlation length {lambda} of the magnetic field, the magnetic Bremsstrahlung radiation of charged relativistic particles unavoidably proceeds to the so-called jitter radiation regime. The cooling timescale of parent particles is identical to the synchrotron cooling time, thus this radiation regime can be produced with very high efficiency in different astrophysical sources characterized by high turbulence. The jitter radiation has distinct spectral features shifted toward high energies, compared to synchrotron radiation. This effect makes the jitter mechanism an attractive broad-band gamma-ray production channel, which, in highly magnetized and turbulent environments, can compete or even dominate over other high-energy radiation mechanisms. In this paper, we present a novel study of the spectral properties of the jitter radiation performed within the framework of perturbation theory. The derived general expression for the spectral power of radiation is presented in a compact and convenient form for numerical calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gold Nanoparticles Enhance the Radiation Therapy of a Murine Squamous Cell Carcinoma

The purpose of this study is to test the hypothesis that gold nanoparticle (AuNP, nanogold)-enhanced radiation therapy (nanogold radiation therapy, NRT) is efficacious when treating the radiation resistant and highly aggressive mouse head and neck squamous cell carcinoma model, SCCVII, and to identify parameters influencing the efficacy of NRT. Subcutaneous (sc) SCCVII leg tumors in mice were irradiated with x-rays at the Brookhaven National Laboratory (BNL) National Synchrotron Light Source (NSLS) with and without prior intravenous (iv) administration of AuNPs. Variables studied included radiation dose, beam energy, temporal fractionation and hyperthermia. AuNP-mediated NRT was shown to be effective for the sc SCCVII model. AuNPs were more effective at 42 Gy than at 30 Gy (both at 68 keV median beam energy) compared to controls without gold. Similarly, at 157 keV median beam energy, 50.6 Gy NRT was more effective than 44 Gy NRT. At the same radiation dose (42 Gy), 68 keV was more effective than 157 keV. Hyperthermia and radiation therapy (RT) were synergistic and AuNPs enhanced this synergy, thereby further reducing TCD50 s (tumor control dose 50%) and increasing long-term survivals. It is concluded that gold nanoparticles enhance the radiation therapy of a radioresistant mouse squamous cell carcinoma. The data show that radiation dose, energy and hyperthermia influence efficacy and better define the potential utility of gold nanoparticles for cancer x-ray therapy.

43 PARTICLE ACCELERATORS↗

AREPO-RT : radiation hydrodynamics on a moving mesh

We introduce AREPO-RT , a novel radiation hydrodynamic (RHD) solver for the unstructured moving-mesh code AREPO . Our method solves the moment-based radiative transfer equations using the M1 closure relation. We achieve second-order convergence by using a slope-limited linear spatial extrapolation and a first-order time prediction step to obtain the values of the primitive variables on both sides of the cell interface. A Harten–Lax–van Leer flux function, suitably modified for moving meshes, is then used to solve the Riemann problem at the interface. The implementation is fully conservative and compatible with the individual time-stepping scheme of AREPO . It incorporates atomic hydrogen (H) and helium (He) thermochemistry, which is used to couple the ultraviolet radiation field to the gas. Additionally, infrared (IR) radiation is coupled to the gas under the assumption of local thermodynamic equilibrium between the gas and the dust. We successfully apply our code to a large number of test problems, including applications such as the expansion of HII regions, radiation pressure-driven outflows, and the levitation of optically thick layer of gas by trapped IR radiation. The new implementation is suitable for studying various important astrophysical phenomena, such as the effect of radiative feedback in driving galactic scale outflows, radiation-driven dusty winds in high-redshift quasars, or simulating the reionization history of the Universe in a self-consistent manner.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-dose radiation from 18 F-FDG PET does not increase cancer frequency or shorten latency but reduces kidney disease in cancer-prone Trp53+/- mice

There is considerable interest in the health effects associated with low-level radiation exposure from medical imaging procedures. Concerns in the medical community that increased radiation exposure from imaging procedures may increase cancer risk among patients are confounded by research showing that low-dose radiation exposure can extend lifespan by increasing the latency period of some types of cancer. The most commonly used radiopharmaceutical for positron emission tomography (PET) scans is 2-[ 18 F] fluoro-2-deoxy-d-glucose ( 18 F-FDG), which exposes tissue to a low-dose, mixed radiation quality: 634 keV β+ and 511 keV γ-rays. The goal of this research was to investigate how modification of cancer risk associated with exposure to low-dose ionising radiation in cancer-prone Trp53 +/- mice is influenced by radiation quality from PET. At 7-8 weeks of age, Trp53 +/- female mice were exposed to one of five treatments: 0 Gy, 10 mGy γ-rays, 10 mGy 18 F-FDG, 4 Gy γ-rays, 10 mGy 18 F-FDG + 4 Gy γ-rays (n > 185 per group). The large 4-Gy radiation dose significantly reduced the lifespan by shortening the latency period of cancer and significantly increasing the number of mice with malignancies, compared with unirradiated controls. The 10 mGy γ-rays and 10 mGy PET doses did not significantly modify the frequency or latency period of cancer relative to unirradiated mice. Similarly, the PET scan administered prior to a large 4-Gy dose did not significantly modify the latency or frequency of cancer relative to mice receiving a dose of only 4 Gy. The relative biological effectiveness of radiation quality from 18 F-FDG, with respect to malignancy, is approximately 1. Furthermore, when non-cancer endpoints were studied, it was found that the 10-mGy PET group had a significant reduction in kidney lesions (P < 0.021), indicating that a higher absorbed dose (20 ± 0.13 mGy), relative to the whole-body average, which occurs in specific tissues, may not be detrimental.

18F-FDG RBE 1.0↗

Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality

Purpose: To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. Methods: In dual-energy CT, besides the material-specific information, one may also synthesize monochromatic images at different energies, which can be used for routine diagnosis similar to conventional polychromatic single-energy images. In this work, the authors assessed whether virtual monochromatic images generated from dual-source CT scanners had an image quality similar to that of polychromatic single-energy images for the same radiation dose. First, the authors provided a theoretical analysis of the optimal monochromatic energy for either the minimum noise level or the highest iodine contrast to noise ratio (CNR) for a given patient size and dose partitioning between the low- and high-energy scans. Second, the authors performed an experimental study on a dual-source CT scanner to evaluate the noise and iodine CNR in monochromatic images. A thoracic phantom with three sizes of attenuating rings was used to represent four adult sizes. For each phantom size, three dose partitionings between the low-energy (80 kV) and the high-energy (140 kV) scans were used in the dual-energy scan. Monochromatic images at eight energies (40 to 110 keV) were generated for each scan. Phantoms were also scanned at each of the four polychromatic single energy (80, 100, 120, and 140 kV) with the same radiation dose. Results: The optimal virtual monochromatic energy depends on several factors: phantom size, partitioning of the radiation dose between low- and high-energy scans, and the image quality metrics to be optimized. With the increase of phantom size, the optimal monochromatic energy increased. With the increased percentage of radiation dose on the low energy scan, the optimal monochromatic energy decreased. When maximizing the iodine CNR in monochromatic images, the optimal energy was lower than that when minimizing noise level. When the total radiation dose was equally distributed between low and high energy in dual-energy scans, for minimum noise, the optimal energies were 68, 71, 74, and 77 keV for small, medium, large, and extra-large (xlarge) phantoms, respectively; for maximum iodine CNR, the optimal energies were 66, 68, 70, 72 keV. With the optimal monochromatic energy, the noise level was similar to and the CNR was better than that in a single-energy scan at 120 kV for the same radiation dose. Compared to an 80 kV scan, however, the iodine CNR in monochromatic images was lower for the small, medium, and large phantoms. Conclusions: In dual-source dual-energy CT, optimal virtual monochromatic energy depends on patient size, dose partitioning, and the image quality metric optimized. With the optimal monochromatic energy, the noise level was similar to and the iodine CNR was better than that in 120 kV images for the same radiation dose. Compared to single-energy 80 kV images, the iodine CNR in virtual monochromatic images was lower for small to large phantom sizes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗