Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

COMPARISONS OF CRYSTALLINE SILICOTITANATE AND RESORCINOL FORMALDEHYDE MEDIA FOR CESIUM REMOVAL BY IN-TANK COLUMN PROCESSING

Chemical and thermal performance of crystalline silicotitanate (CST) and resorcinol-formaldehyde (RF) ion exchange media were predicted for column configurations designed for installation in high level waste tanks and intended for cesium removal from radioactive waste supernates. Modeling predictions for the processing of a known Savannah River Site tank waste composition were generated. In a two column configuration under presumed nominal operating conditions (432 gallon packed bed, 10 gpm liquid flow, 25 C, 45 nCi/g average breakthrough limit) with lead/lag column rotation between processing cycles, approximately two cycles were predicted to treat 1,000,000 gallons of radioactive waste with CST as compared to three cycles predicted for RF. However, this processing mode was shown to be highly unfavorable for RF due to the fact that the lead column is unnecessarily exposed to large radiation doses during movement of the cesium mass transfer zone into the lag column. Thermal modeling calculations indicated that maximum temperatures within stagnant, packed CST and RF columns containing the highest anticipated cesium loading and no active cooling will reach 128 and 78 C, respectively, within 6 days. Active cooling maintains the cesium-saturated CST and RF columns below 88 and 41 C, respectively, under stagnant flow conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

International Recommendations on Reirradiation by Intensity Modulated Radiation Therapy for Locally Recurrent Nasopharyngeal Carcinoma

Reirradiation for locally recurrent nasopharyngeal carcinoma (NPC) is challenging because prior radiation dose delivered in the first course is often close to the tolerance limit of surrounding normal structures. A delicate balance between achieving local salvage and minimizing treatment toxicities is needed. However, high-level evidence is lacking because available reports are mostly retrospective studies on small series of patients. Pragmatic consensus guidelines, based on an extensive literature search and the pooling of opinions by leading specialists, will provide a useful reference to assist decision-making for these difficult decisions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Does Unintentional Splenic Radiation Predict Outcomes After Pancreatic Cancer Radiation Therapy?

Purpose: To determine whether severity of lymphopenia is dependent on radiation dose and fractional volume of spleen irradiated unintentionally during definitive chemoradiation (CRT) in patients with locally advanced pancreatic cancer (LAPC). Methods: 177 patients with LAPC received induction chemotherapy (mainly gemcitabine-based regimens) followed by CRT (median 50.4 Gy with concurrent capecitabine) from January 2006 to December 2012. Absolute lymphocyte count (ALC) was recorded at baseline, before CRT, and 2 to 10 weeks after CRT. Splenic dose-volume histogram (DVH) parameters were reported as mean splenic dose (MSD) and percentage of splenic volume receiving at least 5- (V5), 10- (V10), 15- (V15), and 20-Gy (V20) dose. Overall survival (OS) was analyzed with use of the Cox model, and development of post-CRT severe lymphopenia (ALC <0.5 K/UL) was assessed by multivariate logistic regression with use of baseline and treatment factors. Results: The median post-CRT ALC (0.68 K/UL; range, 0.13-2.72) was significantly lower than both baseline ALC (1.42 K/UL; range, 0.34-3.97; P<.0001) and pre-CRT ALC (1.32 K/UL, range 0.36-4.82; P<.0001). Post-CRT ALC <0.5 K/UL was associated with inferior OS on univariate analysis (median, 11.1 vs 15.3 months; P=.01) and multivariate analysis (hazard ratio = 1.66, P=.01). MSD (9.8 vs 6 Gy, P=.03), median V10 (32.6 vs 16%, P=.04), V15 (23.2 vs 9.5%, P=.03), and V20 (15.4 vs 4.6%, P=.02) were significantly higher in patients with severe lymphopenia than in those without. On multivariate analysis, postinduction lymphopenia (P<.001; odds ratio [OR] = 5.25) and MSD (P=.002; OR= 3.42) were independent predictors for the development of severe post-CRT lymphopenia. Conclusion: Severe post-CRT lymphopenia is an independent predictor of poor OS in LAPC patients receiving CRT. Higher splenic doses increase the risk for the development of severe post-CRT lymphopenia. When clinically indicated, assessment of splenic DVHs before the acceptance of treatment plans may minimize the risk of severe post-CRT lymphopenia.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preliminary results on the feasibility of using ultrasound to monitor intrafractional motion during radiation therapy for pancreatic cancer

Purpose: Substantial intrafraction organ motion during radiation therapy (RT) for pancreatic cancer is well recognized as a major limiting factor for accurate delivery of RT. The aim of this work is to determine the feasibility of monitoring the intrafractional motion of the pancreas or surrounding structures using ultrasound for RT delivery. Methods: Transabdominal ultrasound (TAUS) and 4DCT data were acquired on ten pancreatic cancer patients during radiation therapy process in a prospective study. In addition, TAUS and MRI were collected for five healthy volunteers. The portal vein (PV) and the head of the pancreas (HP) along with other structures were contoured on these images. Volume changes, distance between the HP and PV, and motion difference between the HP and PV were measured to examine whether PV can be used as a motion surrogate for HP. TAUS images were acquired and processed using a research version of the Clarity autoscan ultrasound system (CAUS). Motion monitoring was performed with the ultrasound probe mounted on an arm fixed to the couch. Video segments of the monitoring sessions were captured. Results: On TAUS, PV is better visualized than HP. The measured mean volume deviation for all patients for the HP and PV was 1.4 and 0.6 ml, respectively. The distance between the HP and PV was close to a constant with 0.22 mm mean deviation throughout the ten breathing phases. The mean of the absolute motion difference for all patients was 1.7 ± 0.8 mm in LR, 1.5 ± 0.5 mm in AP, and 2.3 ± 0.7 mm in SI, suggesting that the PV is a good surrogate for HP motion estimation. By using this surrogate, the HP motion tracking using TAUS was demonstrated. Conclusions: Large intrafractional organ motion due to respiratory and/or bowel motion is a limiting factor in administering curative radiation doses to pancreatic tumors. The authors investigate the use of real-time ultrasound to track pancreas motion. Due to the poor visibility of the pancreas head on an ultrasound image, the portal vein is identified as a surrogate. The authors have demonstrated the feasibility of tracking HP motion through the localization of the PV using TAUS. This will potentially allow real-time tracking of intrafractional motion to justify small PTV-margins and to account for unusual motions, thus, improving normal tissue sparing.

60 APPLIED LIFE SCIENCES↗

Pacific Northwest National Laboratory Annual Site Environmental Report for Calendar Year 2023

Pacific Northwest National Laboratory (PNNL), one of the U.S. Department of Energy (DOE) Office of Science’s 10 national laboratories, provides innovative science and technology development in the areas of energy and the environment, fundamental and computational science, and national security. There are three DOE offices within the Richland area. Two are responsible for the Hanford Site, whereas the Pacific Northwest Site Office oversees PNNL. PNNL prepares an Annual Site Environmental Report to meet the requirements of DOE Order 231.1B, Environment, Safety and Health Reporting, and DOE Order 458.1, Radiation Protection of the Public and the Environment, thus assuring that the public is informed of any PNNL-Richland campus or PNNL-Sequim campus event that could adversely affect the health and safety of the public, site staff, or the environment. The report provides a synopsis of ongoing environmental management performance and compliance activities for operations that occur at the PNNL-Richland campus in Richland, Washington, and at the PNNL-Sequim campus near Sequim, Washington. It describes the location of and background for each facility; addresses compliance with applicable DOE, federal, state, and local regulations, and site-specific permits; documents environmental monitoring efforts and their status; presents potential radiation doses to staff and the public in the surrounding areas; and describes DOE-required data quality assurance methods used for data verification. The ASER report describes Compliance with Federal, State, and Local Laws and Regulations in 2023, Environmental Sustainability, Environmental monitoring and dose assessment, Natural and Cultural Resource Management, and Quality Assurance activities that took place during Calendar Year 2023.

40 CFR 61 Subpart H↗

WE-H-201-00: Opportunities for Physicists to Support Low and Mid-Income Countries

The desperate need for radiotherapy in low and mid-income countries (LMICs) has been well documented. Roughly 60 % of the worldwide incidence of cancer occurs in these resource-limited settings and the international community alongside governmental and non-profit agencies have begun publishing reports and seeking help from qualified volunteers. However, the focus of several reports has been on how dire the situation is and the magnitude of the problem, leaving most to feel overwhelmed and unsure as to how to help and why to get involved. This session will help to explain the specific ways that Medical Physicists can uniquely assist in this grand effort to help bring radiotherapy to grossly-underserved areas. Not only can these experts fulfill an important purpose, they also can benefit professionally, academically, emotionally and socially from the endeavor. By assisting others worldwide with their skillset, Medical Physicists can end up helping themselves. Learning Objectives: Understand the need for radiotherapy in LMICs. Understand which agencies are seeking Medical Physicists for help in LMICs. Understand the potential research funding mechanisms are available to establish academic collaborations with LMIC researchers/physicians. Understand the potential social and emotional benefits for both the physicist and the LMIC partners when collaborations are made. Understand the potential for collaboration with other high-income scientists that can develop as the physicist partners with other large institutions to assist LMICs. Wil Ngwa - A recent United Nations Study reports that in developing countries more people have access to cell phones than toilets. In Africa, only 63% of the population has access to piped water, yet, 93% of Africans have cell phone service. Today, these cell phones, Skype, WhatsApp and other information and communication technologies (ICTs) connect us in unprecedented ways and are increasingly recognized as powerful, indispensable to global health. Thanks to ICTs, there are growing opportunities for Medical Physicists to reach out beyond the bunker and impact the world far beyond, without even having to travel. These growing opportunities in global health for Medical Physicists, powered by ICTs, will be highlighted in this presentation, illustrated by high impact examples/models across the globe that are improving patient safety and healthcare outcomes, saving lives. Learning Objectives: Published definitions of global health and the emerging field of global radiation oncology Learn about the transformative potential of ICTs in global radiation oncology care, research and education with focus on Medical Physics Learn about high impact examples of ICT-powered global radiation oncology and the increasing opportunities for participation by Medical Physicists. Yakov Pipman - The number and scope of volunteer Medical Physics activities in support of low-to-middle income countries has been increasing gradually. This happens through a variety of formal channels and to some extent through less formal but personal initiatives. A good deal of effort is dedicated by many, but many more could be recruited through a structured framework to volunteer. We will look into typical volunteer activities and how they fit with organizations already involved in advancing Medical Physics in LMIC. We will identify the range of these organizational activities and their scope to reveal areas of further need. We will point to a few key features of MPWB ( http://www.mpwb.org ) as a volunteering and collaborating structure and how members can get involved and contribute to these efforts at the grass roots level. The goal is that scarce resources can thus be channeled to complement rather than compete with those already in place. Learning Objectives: Understand the strengths and limitations of various organizations that support Medical Physics efforts in LMIC. Learn about ways to volunteer and contribute to Global Health through a grass roots organization focused on Medical Physics in LMIC. Perry Sprawls - With the growing capability and complexity of medical imaging methods in all countries of the world, the expanding role of medical physicists includes optimizing imaging procedures with respect to image quality, radiation dose, and other conflicting factors. With access to appropriate educational resources local medical physicists in all countries can provide direct clinical support and educational for other medical professionals. This is being supported through the process of Collaborative Teaching that combines the capabilities and experience of medical physicists in countries spanning the spectrum of economic, technological, and clinical development. The supporting resources are on the web at: http://www.sprawls.org/resources . Learning Objectives: Identify the medical physics educational needs to support effective and optimized medical imaging procedures. Use collaborative teaching resources to enhance the role of medical physicists in all countries of the world.

60 APPLIED LIFE SCIENCES↗

WE-H-201-01: The Opportunities and Benefits of Helping LMICs: How Helping Them Can Help You

The desperate need for radiotherapy in low and mid-income countries (LMICs) has been well documented. Roughly 60 % of the worldwide incidence of cancer occurs in these resource-limited settings and the international community alongside governmental and non-profit agencies have begun publishing reports and seeking help from qualified volunteers. However, the focus of several reports has been on how dire the situation is and the magnitude of the problem, leaving most to feel overwhelmed and unsure as to how to help and why to get involved. This session will help to explain the specific ways that Medical Physicists can uniquely assist in this grand effort to help bring radiotherapy to grossly-underserved areas. Not only can these experts fulfill an important purpose, they also can benefit professionally, academically, emotionally and socially from the endeavor. By assisting others worldwide with their skillset, Medical Physicists can end up helping themselves. Learning Objectives: Understand the need for radiotherapy in LMICs. Understand which agencies are seeking Medical Physicists for help in LMICs. Understand the potential research funding mechanisms are available to establish academic collaborations with LMIC researchers/physicians. Understand the potential social and emotional benefits for both the physicist and the LMIC partners when collaborations are made. Understand the potential for collaboration with other high-income scientists that can develop as the physicist partners with other large institutions to assist LMICs. Wil Ngwa - A recent United Nations Study reports that in developing countries more people have access to cell phones than toilets. In Africa, only 63% of the population has access to piped water, yet, 93% of Africans have cell phone service. Today, these cell phones, Skype, WhatsApp and other information and communication technologies (ICTs) connect us in unprecedented ways and are increasingly recognized as powerful, indispensable to global health. Thanks to ICTs, there are growing opportunities for Medical Physicists to reach out beyond the bunker and impact the world far beyond, without even having to travel. These growing opportunities in global health for Medical Physicists, powered by ICTs, will be highlighted in this presentation, illustrated by high impact examples/models across the globe that are improving patient safety and healthcare outcomes, saving lives. Learning Objectives: Published definitions of global health and the emerging field of global radiation oncology Learn about the transformative potential of ICTs in global radiation oncology care, research and education with focus on Medical Physics Learn about high impact examples of ICT-powered global radiation oncology and the increasing opportunities for participation by Medical Physicists. Yakov Pipman - The number and scope of volunteer Medical Physics activities in support of low-to-middle income countries has been increasing gradually. This happens through a variety of formal channels and to some extent through less formal but personal initiatives. A good deal of effort is dedicated by many, but many more could be recruited through a structured framework to volunteer. We will look into typical volunteer activities and how they fit with organizations already involved in advancing Medical Physics in LMIC. We will identify the range of these organizational activities and their scope to reveal areas of further need. We will point to a few key features of MPWB ( http://www.mpwb.org ) as a volunteering and collaborating structure and how members can get involved and contribute to these efforts at the grass roots level. The goal is that scarce resources can thus be channeled to complement rather than compete with those already in place. Learning Objectives: Understand the strengths and limitations of various organizations that support Medical Physics efforts in LMIC. Learn about ways to volunteer and contribute to Global Health through a grass roots organization focused on Medical Physics in LMIC. Perry Sprawls - With the growing capability and complexity of medical imaging methods in all countries of the world, the expanding role of medical physicists includes optimizing imaging procedures with respect to image quality, radiation dose, and other conflicting factors. With access to appropriate educational resources local medical physicists in all countries can provide direct clinical support and educational for other medical professionals. This is being supported through the process of Collaborative Teaching that combines the capabilities and experience of medical physicists in countries spanning the spectrum of economic, technological, and clinical development. The supporting resources are on the web at: http://www.sprawls.org/resources . Learning Objectives: Identify the medical physics educational needs to support effective and optimized medical imaging procedures. Use collaborative teaching resources to enhance the role of medical physicists in all countries of the world.

60 APPLIED LIFE SCIENCES↗

WE-H-201-02: Emerging Models and Opportunities in Global Health for Medical Physicists Powered by Information and Communication Technologies

The desperate need for radiotherapy in low and mid-income countries (LMICs) has been well documented. Roughly 60 % of the worldwide incidence of cancer occurs in these resource-limited settings and the international community alongside governmental and non-profit agencies have begun publishing reports and seeking help from qualified volunteers. However, the focus of several reports has been on how dire the situation is and the magnitude of the problem, leaving most to feel overwhelmed and unsure as to how to help and why to get involved. This session will help to explain the specific ways that Medical Physicists can uniquely assist in this grand effort to help bring radiotherapy to grossly-underserved areas. Not only can these experts fulfill an important purpose, they also can benefit professionally, academically, emotionally and socially from the endeavor. By assisting others worldwide with their skillset, Medical Physicists can end up helping themselves. Learning Objectives: Understand the need for radiotherapy in LMICs. Understand which agencies are seeking Medical Physicists for help in LMICs. Understand the potential research funding mechanisms are available to establish academic collaborations with LMIC researchers/physicians. Understand the potential social and emotional benefits for both the physicist and the LMIC partners when collaborations are made. Understand the potential for collaboration with other high-income scientists that can develop as the physicist partners with other large institutions to assist LMICs. Wil Ngwa - A recent United Nations Study reports that in developing countries more people have access to cell phones than toilets. In Africa, only 63% of the population has access to piped water, yet, 93% of Africans have cell phone service. Today, these cell phones, Skype, WhatsApp and other information and communication technologies (ICTs) connect us in unprecedented ways and are increasingly recognized as powerful, indispensable to global health. Thanks to ICTs, there are growing opportunities for Medical Physicists to reach out beyond the bunker and impact the world far beyond, without even having to travel. These growing opportunities in global health for Medical Physicists, powered by ICTs, will be highlighted in this presentation, illustrated by high impact examples/models across the globe that are improving patient safety and healthcare outcomes, saving lives. Learning Objectives: Published definitions of global health and the emerging field of global radiation oncology Learn about the transformative potential of ICTs in global radiation oncology care, research and education with focus on Medical Physics Learn about high impact examples of ICT-powered global radiation oncology and the increasing opportunities for participation by Medical Physicists. Yakov Pipman - The number and scope of volunteer Medical Physics activities in support of low-to-middle income countries has been increasing gradually. This happens through a variety of formal channels and to some extent through less formal but personal initiatives. A good deal of effort is dedicated by many, but many more could be recruited through a structured framework to volunteer. We will look into typical volunteer activities and how they fit with organizations already involved in advancing Medical Physics in LMIC. We will identify the range of these organizational activities and their scope to reveal areas of further need. We will point to a few key features of MPWB ( http://www.mpwb.org ) as a volunteering and collaborating structure and how members can get involved and contribute to these efforts at the grass roots level. The goal is that scarce resources can thus be channeled to complement rather than compete with those already in place. Learning Objectives: Understand the strengths and limitations of various organizations that support Medical Physics efforts in LMIC. Learn about ways to volunteer and contribute to Global Health through a grass roots organization focused on Medical Physics in LMIC. Perry Sprawls - With the growing capability and complexity of medical imaging methods in all countries of the world, the expanding role of medical physicists includes optimizing imaging procedures with respect to image quality, radiation dose, and other conflicting factors. With access to appropriate educational resources local medical physicists in all countries can provide direct clinical support and educational for other medical professionals. This is being supported through the process of Collaborative Teaching that combines the capabilities and experience of medical physicists in countries spanning the spectrum of economic, technological, and clinical development. The supporting resources are on the web at: http://www.sprawls.org/resources . Learning Objectives: Identify the medical physics educational needs to support effective and optimized medical imaging procedures. Use collaborative teaching resources to enhance the role of medical physicists in all countries of the world.

60 APPLIED LIFE SCIENCES↗

WE-H-201-03: Enthusiasm and Generosity of Spirit Necessitate a Volunteering Structure to Make Them More Meaningful

The desperate need for radiotherapy in low and mid-income countries (LMICs) has been well documented. Roughly 60 % of the worldwide incidence of cancer occurs in these resource-limited settings and the international community alongside governmental and non-profit agencies have begun publishing reports and seeking help from qualified volunteers. However, the focus of several reports has been on how dire the situation is and the magnitude of the problem, leaving most to feel overwhelmed and unsure as to how to help and why to get involved. This session will help to explain the specific ways that Medical Physicists can uniquely assist in this grand effort to help bring radiotherapy to grossly-underserved areas. Not only can these experts fulfill an important purpose, they also can benefit professionally, academically, emotionally and socially from the endeavor. By assisting others worldwide with their skillset, Medical Physicists can end up helping themselves. Learning Objectives: Understand the need for radiotherapy in LMICs. Understand which agencies are seeking Medical Physicists for help in LMICs. Understand the potential research funding mechanisms are available to establish academic collaborations with LMIC researchers/physicians. Understand the potential social and emotional benefits for both the physicist and the LMIC partners when collaborations are made. Understand the potential for collaboration with other high-income scientists that can develop as the physicist partners with other large institutions to assist LMICs. Wil Ngwa - A recent United Nations Study reports that in developing countries more people have access to cell phones than toilets. In Africa, only 63% of the population has access to piped water, yet, 93% of Africans have cell phone service. Today, these cell phones, Skype, WhatsApp and other information and communication technologies (ICTs) connect us in unprecedented ways and are increasingly recognized as powerful, indispensable to global health. Thanks to ICTs, there are growing opportunities for Medical Physicists to reach out beyond the bunker and impact the world far beyond, without even having to travel. These growing opportunities in global health for Medical Physicists, powered by ICTs, will be highlighted in this presentation, illustrated by high impact examples/models across the globe that are improving patient safety and healthcare outcomes, saving lives. Learning Objectives: Published definitions of global health and the emerging field of global radiation oncology Learn about the transformative potential of ICTs in global radiation oncology care, research and education with focus on Medical Physics Learn about high impact examples of ICT-powered global radiation oncology and the increasing opportunities for participation by Medical Physicists. Yakov Pipman - The number and scope of volunteer Medical Physics activities in support of low-to-middle income countries has been increasing gradually. This happens through a variety of formal channels and to some extent through less formal but personal initiatives. A good deal of effort is dedicated by many, but many more could be recruited through a structured framework to volunteer. We will look into typical volunteer activities and how they fit with organizations already involved in advancing Medical Physics in LMIC. We will identify the range of these organizational activities and their scope to reveal areas of further need. We will point to a few key features of MPWB ( http://www.mpwb.org ) as a volunteering and collaborating structure and how members can get involved and contribute to these efforts at the grass roots level. The goal is that scarce resources can thus be channeled to complement rather than compete with those already in place. Learning Objectives: Understand the strengths and limitations of various organizations that support Medical Physics efforts in LMIC. Learn about ways to volunteer and contribute to Global Health through a grass roots organization focused on Medical Physics in LMIC. Perry Sprawls - With the growing capability and complexity of medical imaging methods in all countries of the world, the expanding role of medical physicists includes optimizing imaging procedures with respect to image quality, radiation dose, and other conflicting factors. With access to appropriate educational resources local medical physicists in all countries can provide direct clinical support and educational for other medical professionals. This is being supported through the process of Collaborative Teaching that combines the capabilities and experience of medical physicists in countries spanning the spectrum of economic, technological, and clinical development. The supporting resources are on the web at: http://www.sprawls.org/resources . Learning Objectives: Identify the medical physics educational needs to support effective and optimized medical imaging procedures. Use collaborative teaching resources to enhance the role of medical physicists in all countries of the world.

60 APPLIED LIFE SCIENCES↗

WE-H-201-04: Models for Developing Medical Physics Educators and Education Programs in the Developing Countries and the Potential Role of US Universities and Individual Medical Physicists

The desperate need for radiotherapy in low and mid-income countries (LMICs) has been well documented. Roughly 60 % of the worldwide incidence of cancer occurs in these resource-limited settings and the international community alongside governmental and non-profit agencies have begun publishing reports and seeking help from qualified volunteers. However, the focus of several reports has been on how dire the situation is and the magnitude of the problem, leaving most to feel overwhelmed and unsure as to how to help and why to get involved. This session will help to explain the specific ways that Medical Physicists can uniquely assist in this grand effort to help bring radiotherapy to grossly-underserved areas. Not only can these experts fulfill an important purpose, they also can benefit professionally, academically, emotionally and socially from the endeavor. By assisting others worldwide with their skillset, Medical Physicists can end up helping themselves. Learning Objectives: Understand the need for radiotherapy in LMICs. Understand which agencies are seeking Medical Physicists for help in LMICs. Understand the potential research funding mechanisms are available to establish academic collaborations with LMIC researchers/physicians. Understand the potential social and emotional benefits for both the physicist and the LMIC partners when collaborations are made. Understand the potential for collaboration with other high-income scientists that can develop as the physicist partners with other large institutions to assist LMICs. Wil Ngwa - A recent United Nations Study reports that in developing countries more people have access to cell phones than toilets. In Africa, only 63% of the population has access to piped water, yet, 93% of Africans have cell phone service. Today, these cell phones, Skype, WhatsApp and other information and communication technologies (ICTs) connect us in unprecedented ways and are increasingly recognized as powerful, indispensable to global health. Thanks to ICTs, there are growing opportunities for Medical Physicists to reach out beyond the bunker and impact the world far beyond, without even having to travel. These growing opportunities in global health for Medical Physicists, powered by ICTs, will be highlighted in this presentation, illustrated by high impact examples/models across the globe that are improving patient safety and healthcare outcomes, saving lives. Learning Objectives: Published definitions of global health and the emerging field of global radiation oncology Learn about the transformative potential of ICTs in global radiation oncology care, research and education with focus on Medical Physics Learn about high impact examples of ICT-powered global radiation oncology and the increasing opportunities for participation by Medical Physicists. Yakov Pipman - The number and scope of volunteer Medical Physics activities in support of low-to-middle income countries has been increasing gradually. This happens through a variety of formal channels and to some extent through less formal but personal initiatives. A good deal of effort is dedicated by many, but many more could be recruited through a structured framework to volunteer. We will look into typical volunteer activities and how they fit with organizations already involved in advancing Medical Physics in LMIC. We will identify the range of these organizational activities and their scope to reveal areas of further need. We will point to a few key features of MPWB ( http://www.mpwb.org ) as a volunteering and collaborating structure and how members can get involved and contribute to these efforts at the grass roots level. The goal is that scarce resources can thus be channeled to complement rather than compete with those already in place. Learning Objectives: Understand the strengths and limitations of various organizations that support Medical Physics efforts in LMIC. Learn about ways to volunteer and contribute to Global Health through a grass roots organization focused on Medical Physics in LMIC. Perry Sprawls - With the growing capability and complexity of medical imaging methods in all countries of the world, the expanding role of medical physicists includes optimizing imaging procedures with respect to image quality, radiation dose, and other conflicting factors. With access to appropriate educational resources local medical physicists in all countries can provide direct clinical support and educational for other medical professionals. This is being supported through the process of Collaborative Teaching that combines the capabilities and experience of medical physicists in countries spanning the spectrum of economic, technological, and clinical development. The supporting resources are on the web at: http://www.sprawls.org/resources . Learning Objectives: Identify the medical physics educational needs to support effective and optimized medical imaging procedures. Use collaborative teaching resources to enhance the role of medical physicists in all countries of the world.

60 APPLIED LIFE SCIENCES↗

Image quality and localization accuracy in C-arm tomosynthesis-guided head and neck surgery

The image quality and localization accuracy for C-arm tomosynthesis and cone-beam computed tomography (CBCT) guidance of head and neck surgery were investigated. A continuum in image acquisition was explored, ranging from a single exposure (radiograph) to multiple projections acquired over a limited arc (tomosynthesis) to a full semicircular trajectory (CBCT). Experiments were performed using a prototype mobile C-arm modified to perform 3D image acquisition (a modified Siemens PowerMobil). The tradeoffs in image quality associated with the extent of the source-detector arc ({theta}{sub tot}), the number of projection views, and the total imaging dose were evaluated in phantom and cadaver studies. Surgical localization performance was evaluated using three cadaver heads imaged as a function of {theta}{sub tot}. Six localization tasks were considered, ranging from high-contrast feature identification (e.g., tip of a K-wire pointer) to more challenging soft-tissue delineation (e.g., junction of the hard and soft palate). Five head and neck surgeons and one radiologist participated as observers. For each localization task, the 3D coordinates of landmarks pinpointed by each observer were analyzed as a function of {theta}{sub tot}. For all tomosynthesis angles, image quality was highest in the coronal plane, whereas sagittal and axial planes exhibited a substantial decrease in spatial resolution associated with out-of-plane blur and distortion. Tasks involving complex, lower-contrast features demonstrated steeper degradation with smaller tomosynthetic arc. Localization accuracy in the coronal plane was correspondingly high, maintained to <3 mm down to {theta}{sub tot}{approx}30 deg. , whereas sagittal and axial localization degraded rapidly below {theta}{sub tot}{approx}60 deg. . Similarly, localization precision was better than {approx}1 mm within the coronal plane, compared to {approx}2-3 mm out-of-plane for tomosynthesis angles below {theta}{sub tot}{approx}45 deg. . An overall 3D localization accuracy of {approx}2.5 mm was achieved with {theta}{sub tot}{approx} 90 deg. for most tasks. The high in-plane spatial resolution, short scanning time, and low radiation dose characteristic of tomosynthesis may enable the surgeon to collect near real-time images throughout the procedure with minimal interference to surgical workflow. Therefore, tomosynthesis could provide a useful addition to the image-guided surgery arsenal, providing on-demand, high quality image updates, complemented by CBCT at critical milestones in the surgical procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv and above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement in patient management. Dr. McNitt-Gray’s disclosures: Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Prospective Evaluation of Acute Toxicity and Quality of Life After IMRT and Concurrent Chemotherapy for Anal Canal and Perianal Cancer

Purpose: A prospective cohort study was conducted to evaluate toxicity, quality of life (QOL), and clinical outcomes in patients treated with intensity modulated radiation therapy (IMRT) and concurrent chemotherapy for anal and perianal cancer. Methods and Materials: From June 2008 to November 2010, patients with anal or perianal cancer treated with IMRT were eligible. Radiation dose was 27 Gy in 15 fractions to 36 Gy in 20 fractions for elective targets and 45 Gy in 25 fractions to 63 Gy in 35 fractions for gross targets using standardized, institutional guidelines, with no planned treatment breaks. The chemotherapy regimen was 5-fluorouracil and mitomycin C. Toxicity was graded with the National Cancer Institute Common Terminology Criteria for Adverse Events, version 3. QOL was assessed with the European Organization for Research and Treatment of Cancer (EORTC) QLQ-C30 and CR29 questionnaires. Correlations between dosimetric parameters and both physician-graded toxicities and patient-reported outcomes were evaluated by polyserial correlation. Results: Fifty-eight patients were enrolled. The median follow-up time was 34 months; the median age was 56 years; 52% of patients were female; and 19% were human immunodeficiency virus—positive. Stage I, II, III, and IV disease was found in 9%, 57%, 26%, and 9% of patients, respectively. Twenty-six patients (45%) required a treatment break because of acute toxicity, mainly dermatitis (23/26). Acute grade 3 + toxicities included skin 46%, hematologic 38%, gastrointestinal 9%, and genitourinary 0. The 2-year overall survival (OS), disease-free survival (DFS), colostomy-free survival (CFS), and cumulative locoregional failure (LRF) rates were 90%, 77%, 84%, and 16%, respectively. The global QOL/health status, skin, defecation, and pain scores were significantly worse at the end of treatment than at baseline, but they returned to baseline 3 months after treatment. Social functioning and appetite scores were significantly better at 12 months than at baseline. Multiple dose-volume parameters correlated moderately with diarrhea, skin, and hematologic toxicity scores. Conclusion: IMRT reduces acute grade 3 + hematologic and gastrointestinal toxicities compared with reports from non-IMRT series, without compromising locoregional control. The reported QOL scores most relevant to acute toxicities returned to baseline by 3 months after treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A novel property of gold nanoparticles: Free radical generation under microwave irradiation

Purpose: Gold nanoparticles (GNPs) are known to be effective mediators in microwave hyperthermia. Interaction with an electromagnetic field, large surface to volume ratio, and size quantization of nanoparticles (NPs) can lead to increased cell killing beyond pure heating effects. The purpose of this study is to explore the possibility of free radical generation by GNPs in aqueous media when they are exposed to a microwave field. Methods: A number of samples with 500 mM 5,5-dimethyl-1-pyrroline N-oxide (DMPO) in 20 ppm GNP colloidal suspensions were scanned with an electron paramagnetic resonance (EPR)/electron spin resonance spectrometer to generate and detect free radicals. A fixed (9.68 GHz) frequency microwave from the spectrometer has served for both generation and detection of radicals. EPR spectra obtained as first derivatives of intensity with the spectrometer were double integrated to get the free radical signal intensities. Power dependence of radical intensity was studied by applying various levels of microwave power (12.5, 49.7, and 125 mW) while keeping all other scan parameters the same. Free radical signal intensities from initial and final scans, acquired at the same power levels, were compared. Results: Hydroxyl radical (OH⋅) signal was found to be generated due to the exposure of GNP–DMPO colloidal samples to a microwave field. Intensity of OH⋅ signal thus generated at 12.5 mW microwave power for 2.8 min was close to the intensity of OH⋅ signal obtained from a water–DMPO sample exposed to 1.5 Gy ionizing radiation dose. For repeated scans, higher OH⋅ intensities were observed in the final scan for higher power levels applied between the initial and the final scans. Final intensities were higher also for a shorter time interval between the initial and the final scans. Conclusions: Our results observed for the first time demonstrate that GNPs generate OH⋅ radicals in aqueous media when they are exposed to a microwave field. If OH⋅ radicals can be generated close to deoxyribonucleic acid of cells by proper localization of NPs, NP-aided microwave hyperthermia can yield cell killing via both elevated temperature and free radical generation.

60 APPLIED LIFE SCIENCES↗

Five-Year Outcomes, Cosmesis, and Toxicity With 3-Dimensional Conformal External Beam Radiation Therapy to Deliver Accelerated Partial Breast Irradiation

Purpose: To report the interim results from a study comparing the efficacy, toxicity, and cosmesis of breast-conserving treatment with accelerated partial breast irradiation (APBI) or whole breast irradiation (WBI) using 3-dimensional conformal external beam radiation therapy (3D-CRT). Methods and Materials: 102 patients with early-stage breast cancer who underwent breast-conserving surgery were randomized to receive either WBI (n=51) or APBI (n=51). In the WBI arm, 48 Gy was delivered to the whole breast in daily fractions of 2 Gy, with or without additional 10 Gy to the tumor bed. In the APBI arm, patients received 37.5 Gy in 3.75 Gy per fraction delivered twice daily. Toxicity results were scored according to the Radiation Therapy Oncology Group Common Toxicity Criteria. Skin elasticity was measured using a dedicated device (Multi-Skin-Test-Center MC-750-B2, CKelectronic-GmbH). Cosmetic results were assessed by the physician and the patients as good/excellent, regular, or poor. Results: The median follow-up time was 5 years. No local recurrences were observed. No significant differences in survival rates were found. APBI reduced acute side effects and radiation doses to healthy tissues compared with WBI (P<.01). Late skin toxicity was no worse than grade 2 in either group, without significant differences between the 2 groups. In the ipsilateral breast, the areas that received the highest doses (ie, the boost or quadrant) showed the greatest loss of elasticity. WBI resulted in a greater loss of elasticity in the high-dose area compared with APBI (P<.05). Physician assessment showed that >75% of patients in the APBI arm had excellent or good cosmesis, and these outcomes appear to be stable over time. The percentage of patients with excellent/good cosmetic results was similar in both groups. Conclusions: APBI delivered by 3D-CRT to the tumor bed for a selected group of early-stage breast cancer patients produces 5-year results similar to those achieved with conventional WBI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Evaluation of a 160-mm/256-row CT scanner for whole-heart quantitative myocardial perfusion imaging

Purpose: The authors investigated the performance of a recently introduced 160-mm/256-row CT system for low dose quantitative myocardial perfusion (MP) imaging of the whole heart. This platform is equipped with a gantry capable of rotating at 280 ms per full cycle, a second generation of adaptive statistical iterative reconstruction (ASiR-V) to correct for image noise arising from low tube voltage potential/tube current dynamic scanning, and image reconstruction algorithms to tackle beam-hardening, cone-beam, and partial-scan effects. Methods: Phantom studies were performed to investigate the effectiveness of image noise and artifact reduction with a GE Healthcare Revolution CT system for three acquisition protocols used in quantitative CT MP imaging: 100, 120, and 140 kVp/25 mAs. The heart chambers of an anthropomorphic chest phantom were filled with iodinated contrast solution at different concentrations (contrast levels) to simulate the circulation of contrast through the heart in quantitative CT MP imaging. To evaluate beam-hardening correction, the phantom was scanned at each contrast level to measure the changes in CT number (in Hounsfield unit or HU) in the water-filled region surrounding the heart chambers with respect to baseline. To evaluate cone-beam artifact correction, differences in mean water HU between the central and peripheral slices were compared. Partial-scan artifact correction was evaluated from the fluctuation of mean water HU in successive partial scans. To evaluate image noise reduction, a small hollow region adjacent to the heart chambers was filled with diluted contrast, and contrast-to-noise ratio in the region before and after noise correction with ASiR-V was compared. The quality of MP maps acquired with the CT system was also evaluated in porcine CT MP studies. Myocardial infarct was induced in a farm pig from a transient occlusion of the distal left anterior descending (LAD) artery with a catheter-based interventional procedure. MP maps were generated from the dynamic contrast-enhanced (DCE) heart images taken at baseline and three weeks after the ischemic insult. Results: Their results showed that the phantom and animal images acquired with the CT platform were minimally affected by image noise and artifacts. For the beam-hardening phantom study, changes in water HU in the wall surrounding the heart chambers greatly reduced from >±30 to ≤ ± 5 HU at all kVp settings except one region at 100 kVp (7 HU). For the cone-beam phantom study, differences in mean water HU from the central slice were less than 5 HU at two peripheral slices with each 4 cm away from the central slice. These findings were reproducible in the pig DCE images at two peripheral slices that were 6 cm away from the central slice. For the partial-scan phantom study, standard deviations of the mean water HU in 10 successive partial scans were less than 5 HU at the central slice. Similar observations were made in the pig DCE images at two peripheral slices with each 6 cm away from the central slice. For the image noise phantom study, CNRs in the ASiR-V images were statistically higher (p < 0.05) than the non-ASiR-V images at all kVp settings. MP maps generated from the porcine DCE images were in excellent quality, with the ischemia in the LAD territory clearly seen in the three orthogonal views. Conclusions: The study demonstrates that this CT system can provide accurate and reproducible CT numbers during cardiac gated acquisitions across a wide axial field of view. This CT number fidelity will enable this imaging tool to assess contrast enhancement, potentially providing valuable added information beyond anatomic evaluation of coronary stenoses. Furthermore, their results collectively suggested that the 100 kVp/25 mAs protocol run on this CT system provides sufficient image accuracy at a low radiation dose (<3 mSv) for whole-heart quantitative CT MP imaging.

60 APPLIED LIFE SCIENCES↗

WE-D-BRE-04: Modeling Optimal Concurrent Chemotherapy Schedules

Purpose: Concurrent chemo-radiation therapy (CCRT) has become a more common cancer treatment option with a better tumor control rate for several tumor sites, including head and neck and lung cancer. In this work, possible optimal chemotherapy schedules were investigated by implementing chemotherapy cell-kill into a tumor response model of RT. Methods: The chemotherapy effect has been added into a published model (Jeong et al., PMB (2013) 58:4897), in which the tumor response to RT can be simulated with the effects of hypoxia and proliferation. Based on the two-compartment pharmacokinetic model, the temporal concentration of chemotherapy agent was estimated. Log cell-kill was assumed and the cell-kill constant was estimated from the observed increase in local control due to concurrent chemotherapy. For a simplified two cycle CCRT regime, several different starting times and intervals were simulated with conventional RT regime (2Gy/fx, 5fx/wk). The effectiveness of CCRT was evaluated in terms of reduction in radiation dose required for 50% of control to find the optimal chemotherapy schedule. Results: Assuming the typical slope of dose response curve (γ50=2), the observed 10% increase in local control rate was evaluated to be equivalent to an extra RT dose of about 4 Gy, from which the cell-kill rate of chemotherapy was derived to be about 0.35. Best response was obtained when chemotherapy was started at about 3 weeks after RT began. As the interval between two cycles decreases, the efficacy of chemotherapy increases with broader range of optimal starting times. Conclusion: The effect of chemotherapy has been implemented into the resource-conservation tumor response model to investigate CCRT. The results suggest that the concurrent chemotherapy might be more effective when delayed for about 3 weeks, due to lower tumor burden and a larger fraction of proliferating cells after reoxygenation.

60 APPLIED LIFE SCIENCES↗