Search NASA⌕ Search

SEARCH · Search NASA

Results for “Randomized methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Long-Term Failure Patterns and Survival in a Randomized Dose-Escalation Trial for Prostate Cancer. Who Dies of Disease?

Purpose: To report long-term failure patterns and survival in a randomized radiotherapy dose escalation trial for prostate cancer. Materials and Methods: A total of 301 patients with Stage T1b-T3 prostate cancer treated to 70 Gy versus 78 Gy now have a median follow-up of 9 years. Failure patterns and survival were compared between dose levels. The cumulative incidence of death from prostate cancer versus other causes was examined and regression analysis was used to establish predictive factors. Results: Patients with pretreatment prostate-specific antigen (PSA) >10 ng/mL or high-risk disease had higher biochemical and clinical failures rates when treated to 70 Gy. These patients also had a significantly higher risk of dying of prostate cancer. Patients <70 years old at treatment died of prostate cancer nearly three times more frequently than of other causes when they were radiated to 70 Gy, whereas those treated to 78 Gy died of other causes more frequently. Patients age 70 or older treated to 70 Gy died of prostate cancer as often as other causes, and those receiving 78 Gy never died of prostate cancer within 10 years of follow-up. In regression analysis, factors predicting for death from prostate cancer were pretreatment PSA >10.5 ng/mL, Gleason score 9 and 10, recurrence within 2.6 years of radiation, and doubling time of <3.6 months at the time of recurrence. Conclusions: Moderate dose escalation (78 Gy) decreases biochemical and clinical failure as well as prostate cancer death in patients with pretreatment PSA >10 ng/mL or high-risk disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scoring Systems to Estimate Intracerebral Control and Survival Rates of Patients Irradiated for Brain Metastases;Brain metastases; Radiation therapy; Local control; Survival; Prognostic scores

Purpose: To create and validate scoring systems for intracerebral control (IC) and overall survival (OS) of patients irradiated for brain metastases. Methods and Materials: In this study, 1,797 patients were randomly assigned to the test (n = 1,198) or the validation group (n = 599). Two scoring systems were developed, one for IC and another for OS. The scores included prognostic factors found significant on multivariate analyses. Age, performance status, extracerebral metastases, interval tumor diagnosis to RT, and number of brain metastases were associated with OS. Tumor type, performance status, interval, and number of brain metastases were associated with IC. The score for each factor was determined by dividing the 6-month IC or OS rate (given in percent) by 10. The total score represented the sum of the scores for each factor. The score groups of the test group were compared with the corresponding score groups of the validation group. Results: In the test group, 6-month IC rates were 17% for 14-18 points, 49% for 19-23 points, and 77% for 24-27 points (p < 0.0001). IC rates in the validation group were 19%, 52%, and 77%, respectively (p < 0.0001). In the test group, 6-month OS rates were 9% for 15-19 points, 41% for 20-25 points, and 78% for 26-30 points (p < 0.0001). OS rates in the validation group were 7%, 39%, and 79%, respectively (p < 0.0001). Conclusions: Patients irradiated for brain metastases can be given scores to estimate OS and IC. IC and OS rates of the validation group were similar to the test group demonstrating the validity and reproducibility of both scores.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of High-Dose Proton Radiotherapy and Brachytherapy in Localized Prostate Cancer: A Case-Matched Analysis

Purpose: To report a case-matched analysis comparing high-dose external-beam radiation (EBRT) for prostate cancer delivered on Proton Radiation Oncology Group (PROG) 95-09, a randomized trial, with permanent prostate brachytherapy over the same era. Methods: From 1996 to 1999, 196 patients were accrued to the high-dose arm (79.2 Gray equivalent (GyE) using photons and protons) of PROG 95-09 at the Massachusetts General Hospital and Loma Linda University Medical Center. Entry criteria specified T1-2 and prostate-specific antigen {<=}15 ng/mL. When Gleason score >7 was excluded, 177 men were left for case matching. At Massachusetts General Hospital, 203 similar patients were treated by a single brachytherapist from 1997 to 2002. Minimum follow-up was 3 years. Case matching, based on T stage, Gleason score, prostate-specific antigen, and age resulted in 141 matches (282 patients). Median follow-up was 8.6 and 7.4 years for EBRT and brachytherapy, respectively. The primary endpoint was biochemical failure (BF). Results: Using the Phoenix definition, the 8-year BF rates were 7.7% and 16.1% for EBRT and brachytherapy, respectively (p = 0.42). A stratified analysis was performed by risk group. In the EBRT group, 113 and 28 patients were low and intermediate risk, respectively. In the brachytherapy group, 118 and 23 were. When stratified by risk group, the BF rates were similar by either technique. Conclusions: High-dose EBRT and brachytherapy result in similar BF rates for men with localized prostate cancer. Comparative quality-of-life and cost-effectiveness studies are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phonon and magnetic structure in δ-plutonium from density-functional theory

We present phonon properties of plutonium metal obtained from a combination of density-functional-theory (DFT) electronic structure and the recently developed compressive sensing lattice dynamics (CSLD). The CSLD model is here trained on DFT total energies of several hundreds of quasi-random atomic configurations for best possible accuracy of the phonon properties. The calculated phonon dispersions compare better with experiment than earlier results obtained from dynamical mean-field theory. The density-functional model of the electronic structure consists of disordered magnetic moments with all relativistic effects and explicit orbital-orbital correlations. The magnetic disorder is approximated in two ways: (i) a special quasi-random structure and (ii) the disordered-local-moment (DLM) method within the coherent potential approximation. Magnetism in plutonium has been debated intensely, However, the present magnetic approach for plutonium is validated by the close agreement between the predicted magnetic form factor and that of recent neutron-scattering experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determination of sputtered atom densities and velocities via simulation

Transport of sputtered atoms in a plasma sputtering unit is simulated using two known elastic collision models. The methods of studying the collision of two atoms are isotropic random scattering angle in the center of mass frame and the so-called center to center collision model in which the impact parameter is ignored and the two particles collide such as two material points. The obtained results for the density and velocity of sputtered atoms in both models are compared with some experimental reports. This investigation shows that the copper and argon atoms present pointlike behavior in the collision process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hooks versus Pedicle Screws at the Upper Instrumented Level: An In Vitro Biomechanical Comparison

Study Design. Controlled laboratory study Objective. To compare motions at the upper instrumented vertebra (UIV) and supra-adjacent level (UIV+1) between two fixation techniques in thoracic posterior spinal fusion (PSF) constructs. We hypothesized there would be greater motion at UIV+1 after cyclic loading across all constructs and bilateral pedicle screws (BPS) with posterior ligamentous compromise would demonstrate the greatest UIV+1 range of motion (ROM). Summary of Background Data. Proximal junctional kyphosis (PJK) is a well-recognized complication following long thoraco-lumbar PSF, however its mechanism is poorly understood. Methods. Twenty-seven thoracic functional spine units (FSU) were randomly divided into three UIV fixation groups (n=9): (1) BPS, (2) bilateral transverse process hooks (TPH), and (3) BPS with compromise of the posterior elements between UIV and UIV+1 (BPS-C). Specimens were tested on a servohydraulic materials testing system in native state, following instrumentation, and after cyclic loading. FSUs were loaded in flexion-extension (FE), lateral bending (LB), and axial rotation (AR). Results. After cyclic testing, the TPH group had a mean 29.4% increase in FE ROM at UIV+1 versus 76.6% in the BPS group ( P <0.05). The BPS-C group showed an increased FE of 49.9% and 62.19% with sectioning of the facet joints and interspinous ligament respectively prior to cyclic testing. Conclusion. Bilateral pedicle screws at the UIV led to greater motion at UIV+1 compared to bilateral TPH after cyclic loading. This is likely due to the increased rigidity of BPS compared to TPH leading to a “softer” transition between the TPH construct and native anatomy at the supra-adjacent level. Facet capsule compromise led to a 49.9% increase in UIV+1 motion, underscoring the importance of preserving the posterior ligamentous complex. Clinical studies that account for fusion rates are warranted to determine if constructs with a “soft transition” result in less PJK in vivo.

Neurosciences & Neurology↗

SU-E-J-275: Impact of the Intra and Inter Observer Variability in the Delineation of Parotid Glands On the Dose Calculation During Head and Neck Helical Tomotherapy

Purpose: The intra- and inter-observer variability in delineation of the parotids on the kilo-voltage computed tomography (kVCT) and mega-voltage computed tomography (MVCT) were examined to establish their impact on the dose calculation during adaptive head and neck helical tomotherapy (HT). Methods: Three observers delineated left and right parotids for ten randomly selected patients with oropharynx cancer treated on HT. The pre-treatment kVCT and the MVCT from the first fraction of irradiation were selected to delineation. The delineation procedure was repeated three times by each observer. The parotids were delineated according to the institutional protocol. The analyses included intra-observer reproducibility and inter-structure, -observer and -modality variability of the volume and dose. Results: The differences between the left and right parotid outlines were not statistically significant (p>0.3). The reproducibility of the delineation was confirmed for each observer on the kVCT (p>0.2) and on the MVCT (p>0.1). The inter-observer variability of the outlines was significant (p<0.001) as well as the inter-modality variability (p<0.006). The parotids delineated on the MVCT were 10% smaller than on the kVCT. The inter-observer variability of the parotids delineation did not affect the average dose (p=0.096 on the kVCT and p=0.176 on the MVCT). The dose calculated on the MVCT was higher by 3.3% than dose from the kVCT (p=0.009). Conclusion: Usage of the institutional protocols for the parotids delineation reduces intra-observer variability and increases reproducibility of the outlines. These protocols do not eliminate delineation differences between the observers, but these differences are not clinically significant and do not affect average doses in the parotids. The volumes of the parotids delineated on the MVCT are smaller than on the kVCT, which affects the differences in the calculated doses.

60 APPLIED LIFE SCIENCES↗

SU-E-T-225: It Is Necessary to Contouring the Brainstem On MRI Images in Radiotherapy of Head and Neck Cancer

Purpose: To analyze the error in contouring the brainstem for patients with head and neck cancer who underwent radiotherapy based on computed tomography (CT) and magnetic resonance (MR) images. Methods: 20 brain tumor and 17 nasopharyngeal cancer patients were randomly selected. Each patient underwent MR and CT scanning. For each patient, one observer contoured the brainstem on CT and MR images for 10 times, and 10 observers from five centers delineated the brainstem on CT and MR images only one time. The inter- and intra-observers volume and outline variations were compared. Results: The volumes of brainstem contoured by inter- and intra-observers on CT and MR images were similar (p>0.05). The reproducibility of contouring brainstem on MR images was better than that on CT images (p<0.05) for both inter- and intra-observer variability. The inter- and intra-observer for contouring on CT images reached mean values of 0.81±0.05 (p>0.05) and of 0.85±0.05 (p>0.05), respectively, while on MR images these respective values were 0.90±0.05 (p>0.05) and 0.92±0.04 (p>0.05). Conclusion: Contouring the brainstem on MR images was more accurate and reproducible than that on CT images. Precise information might be more helpful for protecting the brainstem radiation injury the patients whose lesion were closed to brainstem.

60 APPLIED LIFE SCIENCES↗

SU-E-T-65: A Prospective Trial of Open Face Masks for Head and Neck Radiotherapy

Purpose: Open face head and neck masks allow for active patient monitoring during treatment and may reduced claustrophobia and anxiety compared to closed masks. The ability of open masks to limit intrafraction motion and to preserve the patient shape/position from simulation over protracted treatments should be considered. Methods: Thirty-two head and neck patients were prospectively randomized to treatment in a closed mask or a novel open face mask. All patients received daily volumetric imaging. The daily images were automatically rigidly registered to the planning CT’s offline using a commercial image processing tool. The shifts needed to optimize the registration, the mutual information coefficient (MI), and the Pearson correlation (PC) coefficients were recorded to evaluate shape preservation. The open group was set-up and monitored with surface imaging at treatment. The real time surface imaging information was recorded to evaluate intrafraction motion. Results: Sixteen patients were included in each group. Evaluations were made over a total of 984 fractions. The mean MI and PC showed significantly higher shape preservation for the open group than for the closed group (p = 0). The mean rotations for the open group were smaller or < 0.15° larger versus the closed group. The mean intrafraction motion for the open group was 0.93 +/−0.99 mm (2 SD). The maximum single fraction displacement was 3.2 mm. Fourteen of 16 patients showed no significant correlation of motion with fraction number (p > 0.05). Conclusion: The open masks preserved shape as well as the closed masks, and they limited motion to < 2 mm for 95% of the treated fractions. These results are consistent over treatment courses of up to 35 fractions. The open mask is suitable for treatment with or without active monitoring. This work was partially supported by Qfix.

60 APPLIED LIFE SCIENCES↗

SU-E-T-789: Validation of 3DVH Accuracy On Quantifying Delivery Errors Based On Clinical Relevant DVH Metrics

Purpose: Detection of treatment delivery errors is important in radiation therapy. However, accurate quantification of delivery errors is also of great importance. This study aims to evaluate the 3DVH software’s ability to accurately quantify delivery errors. Methods: Three VMAT plans (prostate, H&N and brain) were randomly chosen for this study. First, we evaluated whether delivery errors could be detected by gamma evaluation. Conventional per-beam IMRT QA was performed with the ArcCHECK diode detector for the original plans and for the following modified plans: (1) induced dose difference error up to ±4.0% and (2) control point (CP) deletion (3 to 10 CPs were deleted) (3) gantry angle shift error (3 degree uniformly shift). 2D and 3D gamma evaluation were performed for all plans through SNC Patient and 3DVH, respectively. Subsequently, we investigated the accuracy of 3DVH analysis for all cases. This part evaluated, using the Eclipse TPS plans as standard, whether 3DVH accurately can model the changes in clinically relevant metrics caused by the delivery errors. Results: 2D evaluation seemed to be more sensitive to delivery errors. The average differences between ECLIPSE predicted and 3DVH results for each pair of specific DVH constraints were within 2% for all three types of error-induced treatment plans, illustrating the fact that 3DVH is fairly accurate in quantifying the delivery errors. Another interesting observation was that even though the gamma pass rates for the error plans are high, the DVHs showed significant differences between original plan and error-induced plans in both Eclipse and 3DVH analysis. Conclusion: The 3DVH software is shown to accurately quantify the error in delivered dose based on clinically relevant DVH metrics, where a conventional gamma based pre-treatment QA might not necessarily detect.

60 APPLIED LIFE SCIENCES↗

SU-D-207A-07: The Effects of Inter-Cycle Respiratory Motion Variation On Dose Accumulation in Single Fraction MR-Guided SBRT Treatment of Renal Cell Carcinoma

Purpose: To assess the dose deposition in simulated single-fraction MR-Linac treatments of renal cell carcinoma, when inter-cycle respiratory motion variation is taken into account using online MRI. Methods: Three motion characterization methods, with increasing complexity, were compared to evaluate the effect of inter-cycle motion variation and drifts on the accumulated dose for an SBRT kidney MR-Linac treatment: 1) STATIC, in which static anatomy was assumed, 2) AVG-RESP, in which 4D-MRI phase-volumes were time-weighted, based on the respiratory phase and 3) PCA, in which 3D volumes were generated using a PCA-model, enabling the detection of inter-cycle variations and drifts. An experimental ITV-based kidney treatment was simulated in a 1.5T magnetic field on three volunteer datasets. For each volunteer a retrospectively sorted 4D-MRI (ten respiratory phases) and fast 2D cine-MR images (temporal resolution = 476ms) were acquired to simulate MR-imaging during radiation. For each method, the high spatio-temporal resolution 3D volumes were non-rigidly registered to obtain deformation vector fields (DVFs). Using the DVFs, pseudo-CTs (generated from the 4D-MRI) were deformed and the dose was accumulated for the entire treatment. The accuracies of all methods were independently determined using an additional, orthogonal 2D-MRI slice. Results: Motion was most accurately estimated using the PCA method, which correctly estimated drifts and inter-cycle variations (RMSE=3.2, 2.2, 1.1mm on average for STATIC, AVG-RESP and PCA, compared to the 2DMRI slice). Dose-volume parameters on the ITV showed moderate changes (D99=35.2, 32.5, 33.8Gy for STATIC, AVG-RESP and PCA). AVG-RESP showed distinct hot/cold spots outside the ITV margin, which were more distributed for the PCA scenario, since inter-cycle variations were not modeled by the AVG-RESP method. Conclusion: Dose differences were observed when inter-cycle variations were taken into account. The increased inter-cycle randomness in motion as captured by the PCA model mitigates the local (erroneous) hotspots estimated by the AVG-RESP method.

60 APPLIED LIFE SCIENCES↗

SU-F-T-422: Detection of Optimal Tangential Partial Arc Span for VMAT Planning in IntactLeft-Breast Treatment

Purpose: This study was designed to investigate an appropriate arc span for intact partial Left breast irradiation by VMAT planning. Methods: Four cases of carcinoma left intact breast was chosen randomly for this study. Both medial tangential and left-lateral tangential arc (G20°, G25°, G30°, G35°, G40°) were used having the same length and bilaterally symmetric. For each patient base plan was generated for 30° arc and rest of other arc plans were generated by keeping all plan parameters same, only arc span were changed. All patient plans were generated on treatment planning system Monaco (V 5.00.02) for 50 Gy dose in 25 fractions. PTV contours were clipped 3 mm from skin (patient). All plans were normalized in such a way that 95 % of prescription dose would cover 96 % of PTV volume. Results: Mean MU for 20°, 25°, 30°, 35° and 40° were 509 ± 18.8, 529.1 ± 20.2, 544.4 ± 20.8, 579.1 ±51.8, 607.2 ± 40.2 similarly mean hot spot (volume covered by 105% of prescription dose) were 2.9 ± 1.2, 3.7 ± 3.0, 1.5 ± 1.7, 1.3±0.6, 0.4 ± 0.4, mean contralateral breast dose (cGy) were 180.4 ± 242.3, 71.5 ± 52.7, 76.2 ± 58.8, 85.9 ± 70.5, 90.7 ± 70.1, mean heart dose (cGy) were 285.8 ± 87.2, 221.2 ± 62.8, 274.5 ± 95.5, 234.8 ± 73.8, 263.2 ± 81.6, V20 for ipsilateral lung were 15.4 ± 5.3, 14.3 ± 3.6, 15.3 ± 2.9, 14.2 ± 3.9, 14.7 ± 3.2 and V5 for ipsilateral lung were 33.9 ± 8.2, 31.0 ± 3.5, 42.6 ±15.6, 36.4 ± 12.9, 37.0 ± 7.5. Conclusion: The study concluded that appropriate arc span used for tangential intact breast treatment was optimally 30° because larger arc span were giving lower isodose spill in ipsilateral lung and smaller arc were giving heterogeneous dose distribution in PTV.

60 APPLIED LIFE SCIENCES↗

NF-κB perturbation reveals unique immunomodulatory functions in Prx1 + fibroblasts that promote development of atopic dermatitis

Skin is composed of diverse cell populations that cooperatively maintain homeostasis. Up-regulation of the nuclear factor κB (NF-κB) pathway may lead to the development of chronic inflammatory disorders of the skin, but its role during the early events remains unclear. Here, through analysis of single-cell RNA sequencing data via iterative random forest leave one out prediction, an explainable artificial intelligence method, we identified an immunoregulatory role for a unique paired related homeobox-1 (Prx1) + fibroblast subpopulation. Disruption of Ikkb–NF-κB under homeostatic conditions in these fibroblasts paradoxically induced skin inflammation due to the overexpression of C-C motif chemokine ligand 11 (CCL11; or eotaxin-1) characterized by eosinophil infiltration and a subsequent T H 2 immune response. Because the inflammatory phenotype resembled that seen in human atopic dermatitis (AD), we examined human AD skin samples and found that human AD fibroblasts also overexpressed CCL11 and that perturbation of Ikkb–NF-κB in primary human dermal fibroblasts up-regulated CCL11. Monoclonal antibody treatment against CCL11 was effective in reducing the eosinophilia and T H 2 inflammation in a mouse model. Together, the murine model and human AD specimens point to dysregulated Prx1 + fibroblasts as a previously unrecognized etiologic factor that may contribute to the pathogenesis of AD and suggest that targeting CCL11 may be a way to treat AD-like skin lesions.

60 APPLIED LIFE SCIENCES↗

Gaussian variational ansatz in the problem of anomalous sea waves: Comparison with direct numerical simulation

The nonlinear dynamics of an obliquely oriented wave packet on a sea surface is analyzed analytically and numerically for various initial parameters of the packet in relation to the problem of the so-called rogue waves. Within the Gaussian variational ansatz applied to the corresponding (1+2)-dimensional hyperbolic nonlinear Schrödinger equation (NLSE), a simplified Lagrangian system of differential equations is derived that describes the evolution of the coefficients of the real and imaginary quadratic forms appearing in the Gaussian. This model provides a semi-quantitative description of the process of nonlinear spatiotemporal focusing, which is one of the most probable mechanisms of rogue wave formation in random wave fields. The system of equations is integrated in quadratures, which allows one to better understand the qualitative differences between linear and nonlinear focusing regimes of a wave packet. Predictions of the Gaussian model are compared with the results of direct numerical simulation of fully nonlinear long-crested waves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Speckle-based three-dimensional velocity measurement using spatial filtering velocimetry

We present an optical method for measuring the real-time three-dimensional (3D) translational velocity of a diffusely scattering rigid object observed through an imaging system. The method is based on a combination of the motion of random speckle patterns and regular fringe patterns. The speckle pattern is formed in the observation plane of the imaging system due to reflection from an area of the object illuminated by a coherent light source. The speckle pattern translates in response to in-plane translation of the object, and the presence of an angular offset reference wave coinciding with the speckle pattern in the observation plane gives rise to interference, resulting in a fringe pattern that translates in response to the out-of-plane translation of the object. Numerical calculations are performed to evaluate the dynamic properties of the intensity distribution and the response of realistic spatial filters designed to measure the three components of the object's translational velocity. Furthermore, experimental data are presented that demonstrate full 3D velocity measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of stacked ensemble machine learning for the detection of surrogate plutonium contamination in soil via LIBS

Supervised machine learning methods have demonstrated increased utility for the quantification of lanthanide and actinide elements in atomic spectroscopy applications. This study implements laser-induced breakdown spectroscopy (LIBS) for the identification of plutonium surrogate material (CeO 2 ) in soil matrices by training supervised machine learning methods on the recorded spectral data. A bagged ensemble using Random Forest yields the highest sensitivity predictions with a detection limit of 0.015 wt.% CeO 2 . However, high precision in Ce content prediction required the use of a stacked ensemble regression, which provided the superlative Ce quantification model with an error of 0.107% and a detection limit of 0.022 wt.%. Furthermore, the high performance of the stacked ensemble demonstrates its potential to enhance the accuracy and sensitivity of nuclear contaminant detection using field-deployable spectroscopic analyzers in real-world scenarios.

47 OTHER INSTRUMENTATION↗

Unsupervised Identification of Study Descriptors in Toxicology Research: An Experimental Study

Identifying and extracting data elements such as study descriptors in publication full texts is a critical yet manual and labor-intensive step required in a number of tasks. In this paper we address the question of identifying data elements in an unsupervised manner. Specifically, provided a set of criteria describing specific study parameters, such as species, route of administration, and dosing regimen, we develop an unsupervised approach to identify text segments relevant to the criteria. A binary classifier trained to identify publications that met the criteria performs better when trained on the candidate sentences than when trained on sentences randomly picked from the text, supporting the intuition that our method is able to accurately identify study descriptors.

Herrmannova, Dasha↗

Dimension reduction for PDE using local Karhunen Loeve expansions [Poster]

The objectives were to develop efficient methods for sampling linear partial differential equations subject to uncertain random fields, use domain decomposition and local Karhunen Loeve expansions (KLE) to represent a random field with small correlation length with local KLE defined over subdomains with relatively larger correlation lengths, and show the use of local KLE reduces the high dimensional global field to a set of lower dimensional KLE.

97 MATHEMATICS AND COMPUTING↗