Search NASA⌕ Search

SEARCH · Search NASA

Results for “Retrofitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Thermal Energy Storage Selection for Near Term Nuclear Integration

Thermal energy storage (TES) integration with existing and future light water reactors (LWRs) has the capability to increase the deployment options and uses for the large amounts of heat produced in nuclear reactor cores. The present method of exclusively producing electricity has become less economical with increases in renewable energy penetration leading to times of low or negative electricity prices. Some response to this new grid reality has been to begin load following nuclear reactors, an unideal choice due to the relatively small modular cost of producing nuclear energy compared to the revenue that could be received by using all of the heat produced. To support research in this area, Idaho National Laboratory (INL) has joined with Utah Associated Municipal Power Systems (UAMPS) on the Carbon Free Power Project (CFPP) to contract the Joint Use Modular Plant (JUMP). CFPP is planned to be a 12-module NuScale operating site built on INL property, with the first module dedicated to JUMP for research, development, and demonstration purposes. The JUMP module coming online around the beginning of fiscal year 2027 in the current project timeline. One primary goal of JUMP is to demonstrate TES integrated with an operating LWR in a real-world environment. TES integration will allow for the demonstration of nuclear power’s capability to participate in grid load following without reactor cycling, process heat integration, and electrical ancillary market opportunities. The goal of this research is to support both SMR deployment opportunities as well as support LWR retrofit capabilities. In a discussion limited to load following or energy arbitration, “charging” and “discharging” can be simply defined. TES charging refers to time when energy is removed from the nuclear reactor power conversion cycle and directed to be stored in the TES storage medium resulting in less available energy available for grid output. Discharging refers to the process of releasing energy stored in the TES medium and having an increase in grid. This paper quantifies energy storage technologies for use with nuclear reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Risk Assessment and Ventilation Modeling for Hydrogen Release in Vehicle Repair Garages

The availability of repair garage infrastructure for hydrogen fuel cell vehicles is becoming increasingly important for future industry growth. Ventilation requirements for hydrogen fuel cell vehicles can affect both retrofitted and purpose-built repair garages and the costs associated with these requirements can be significant. A hazard and operability study (HAZOP) was performed to identify key risk-significant scenarios related to hydrogen vehicles in a repair garage. Detailed simulations and modeling were performed using appropriate computational tools to estimate the location, behavior, and severity of hydrogen release based on key HAZOP scenarios. This work compares current fire code requirements to an alternate ventilation strategy to further reduce potentially hazardous conditions. Overall, the amount of flammable mass of hydrogen at any one time in the simulation is low compared to the total mass of hydrogen released, due to the low flow rate of a low pressure release. It is shown that position, direction, and velocity of ventilation have a significant impact on the amount of instantaneous flammable mass in the domain.

33 ADVANCED PROPULSION SYSTEMS↗

Energy Saving Quantification on Ductless Heat Pump (DHP) in Existing Homes

In residential retrofit applications, ductless mini-split heat pumps (DHP) are often reported to have high-energy savings potential, depending on the system they are supplementing or replacing. However, recently, there have been a number of utility studies and analyses indicating these energy savings are not being achieved when the existing system is left in place for backup heating or air conditioning. The Pacific Northwest National Laboratory conducted a three-phase project to help determine which control strategies would have the most energy savings impact in various climate zones around the United States. The first phase developed the standalone simulation model for the PNNL Lab Homes and investigated the energy-saving potential from different control strategies and HVAC system configurations. The second phase focused on conducting experiments in the PNNL Lab Homes, which tested the most promising solutions that were modeled in the first phase. The third phase used the field data to calibrate the simulation model and then extrapolated the results to different climate locations and different building sizes. This report focuses on the third phase of the study, including five major parts: model calibration, parametric model setup, results, a sensitivity analysis of air leakage rate, and conclusions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maximizing the Use of Ductless Mini-Splits in Homes with Existing Central or Zonal Heating and Cooling Equipment

In the residential retrofit application, ductless mini-split heat pumps (DHP) are often reported to hold high-energy savings potential, depending on the system they are supplementing or replacing. However, of late, there have been a number of studies and analyses indicating these energy savings are not being achieved. The primary goal of this project was to determine the most cost effective (lowest cost for the most energy saved) and persistent (e.g. automated, hard to change, etc.) solution for controlling a ductless heat pump in an existing home with central forced air furnace. Various control strategies were tested at the Pacific Northwest National Laboratory Lab Homes to compare the energy savings between the different energy efficient control strategies. A maximum of 40% energy savings was realized by using the ductless mini-split as the primary heat source with the central air conditioning unit as the secondary source.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wyoming CCUS Study: Regional Electricity and Environmental Markets

This study is accompanies the Leonardo Technologies, Inc. study performed for the Office of Fossil Energy entitled: ''Wyoming Carbon Capture, Utilization, and Storage (CCUS) Report''. In this study, NETL examined the regional electricity and environmental markets impacts of maintaining coal-fired generating units identified for retirement in the 2019 PacifiCorp Integrated Resource Plan (IRP) through retrofit with CCUS. In this study, the authors propose an alternative least cost resource portfolio that includes a CCUS option along with resources identified in the IRP required to meet service obligations. This alternative portfolio is estimated to produce a lower CO 2 emissions footprint and a lower cost to the consumer than the proposed IRP.

01 COAL, LIGNITE, AND PEAT↗

Integration of a Concentrating Solar Steam Topping Turbine to an Existing Geothermal Binary Power Plant (CRADA CRD-17-700 Final Report)

U.S. Geothermal Inc. is a publicly traded leading renewable energy company focused on the development, production, and sale of electricity from geothermal energy with operating generation facilities at Raft River, Idaho; San Emidio, Nevada; and Neal Hot Springs, Oregon. (U.S. Geothermal was acquired by Ormat Technologies, Inc. since the execution of this project). This project will evaluate the integration of a concentrating solar steam topping cycle with a geothermal bottoming binary cycle. This hybrid plant configuration will enable high efficiency conversion of the solar heat to electrical power, while simultaneously increasing the power output of the bottoming cycle. Such a design has the potential to reduce the cost of electrical power from concentrating solar power (CSP) and geothermal plants, and a viable design could be deployed at existing geothermal plants that have experienced resource productivity decline as well as in greenfield projects. This analysis will examine US Geothermal’s Raft River power plant for implementation of this concept. INL and NREL have previously collaborated in the analysis of geo-solar hybrid power plants. These two labs will again work together to model the solar field, steam-topping, and geothermal bottoming cycles in order to investigate the performance of the proposed cycle. This analysis will provide US Geothermal with technical information including equipment specifications and estimated power generation necessary to advance the concept toward implementation. A successful project outcome has two parts: One would be for US Geothermal to have a process flow diagram (heat and mass balance), and performance parameters for the major pieces of equipment. US Geothermal could then use this information evaluate the techno-economic feasibility of the hybrid power cycle, and serve as the basis for subsequent detailed equipment design, purchase, and installation of the cycle. The second would be for the developed solution to be published by DOE for use by other geothermal developers both to retrofit underperforming plants and to lower the LCOE of new developments.

15 GEOTHERMAL ENERGY↗

Updates to Relevance Vector Machine: Multiclass Classification, Variable Selection, and Proof-of-Concept Application to Safeguards Fresh Fuel Verification using List-Mode Neutron Collar Data

To expand the capabilities of safeguards authorities to verify the integrity of fresh fuel assemblies, Oak Ridge National Laboratory has retrofit the existing electronics of the JCC-71 uranium neutron coincidence collar, which contains 18 3 He neutron detectors and an external 241 AmLi(α, n) neutron interrogation source arranged to surround a fresh nuclear fuel assembly. The new electronics system allows analysts to record list-mode neutron multiplicity data in addition to the singles and doubles rates that are currently measured. Based on previous proof-of-concept research, analysis of these new data will identify off-normal fuel configurations in an assembly and characterize or localize the specific partial fuel defects. The purpose of this report it to document the analysis algorithm development and then to demonstrate its capability for the safeguards verification of fresh fuel assemblies using list mode neutron collar data. To analyze the complex list-mode data collected with the upgraded uranium neutron collar, multivariate classification algorithms are being developed using a novel classification method, the relevance vector machine. This approach may be applied to multiclass problems to estimate the probability that test data belongs to one of many possible classes of data. In addition, our method identifies the most useful variables/channels for making predictions, which illuminates the basis for the model’s predictions, and this interpretability is largely unique among data analytics methods. Variable selection occurs during model training and parameter tuning and does not need any external hyperparameter tuning routines. Finally, we apply the modified relevance vector machine to a simulated dataset of list-mode neutron collar data generated with the radiation transport code MCNP. The method can correctly identify off-normal fuel configurations, categorize the data according to four fuel defect scenarios, and rank the channels in the data according to prediction utility. For nuclear safeguards applications, it is concluded that this method has the potential to increase the sensitivity and reliability to detect missing fuel rods from a standard 17 x 17 Pressurized Water Reactor (PWR) fresh fuel assembly. Within this analysis, “off-normal” (i.e., missing fuel rods) were correctly classified in 17 simulated test scenarios with one quarter (25%) of the fresh fuel rods missing using a training data set of 58 simulated measurements.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EDS V26 Vessel Clamp Explosive Test Report

This report documents the results of explosive re-qualification tests of the EDS V26 Vessel that were conducted at Sandia National Laboratories in Albuquerque, New Mexico in May 2015 following the retrofitting of the vessel with a three piece clamp for use on the P2A system. The V26 containment vessel is the second EDS vessel to be fabricated under Code Case 2564 of the ASME Boiler and Pressure Vessel Code, which provides rules for the design of impulsively loaded vessels. The explosive rating for the vessel, based on the code case, is nine (9) pounds TNT-equivalent for up to 637 detonations. The goals of the tests were to qualify the vessel, particularly the clamping system, for explosive use. The explosive tests consisted of a 9 pound bare charge of Composition C-4 (equivalent to 11.25 pounds TNT), followed by a 7.2 pound bare charge of Composition C-4 (equivalent to 9 pounds of TNT). Helium permeation measurements of the seal and strain measurements using a pi tape and strain gauges were made. All vessel acceptance criteria were met.

36 MATERIALS SCIENCE↗

National Rotor Testbed Requirements. Draft

This document serves both as a guide and a record for requirements management associated with design of retrofit rotors for the Sandia SWiFT turbines. The rotors will support a long-term experimental campaign. Data gathered during the campaign will support formal verification and validation of complex flow numerical models for prediction of metrics deemed important for wind energy plant efficiency. These integrated projects involve multiple years of effort, dozens of engineers and collaborators, and dozens of stakeholders in the form of the research community, National Lab staff, and DOE staff. Creating of formal, written requirements will ensure flow-down of activities from high-level goals, aid communication, and enable clear verification of activities. A custom requirements schema is created and described. Commercial requirements management software —IBM Rational DOORS—is used to organize the information and ensure traceability. This document serves as a record of the process as well as a record of the exported, detailed contents of the DOORS database.

17 WIND ENERGY↗

Best Practices Guide: Benchmarking Energy Efficiency in Laboratories

Purpose and Audience A wide spectrum of laboratory owners, ranging from universities to federal agencies, have explicit goals for energy efficiency and greenhouse gas reductions in their facilities. For example, new federal buildings and major renovations of existing buildings are to reduce fossil fuel-generated energy consumption by 90% in 2025, and 100% in 2030, compared with a 2003 baseline (FEMP n.d.). Minnesota SB2030 standard requires achieving an 80% reduction from the average building baseline for commercial, institutional, and industrial buildings (SB2030 n.d). A laboratory—new or existing—is much more likely to meet energy efficiency goals if quantitative metrics and targets are explicitly specified and tracked over the life cycle of the building, from design through construction, commissioning, operations, and renovations. If efficiency targets are not explicitly and properly defined, any additional capital costs or design time associated with attaining higher efficiencies can be difficult to justify relative to other priorities. The purpose of this guide is to provide guidance on how to specify and compute energy efficiency metrics and benchmarks for laboratories, at the whole-building as well as the system level. The information in this guide can be used to incorporate quantitative metrics and targets into new construction or retrofit of existing facilities. For information on strategies and technologies to achieve energy efficiency, the reader is referred to I2SL resources, including technology best practice guides and case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Unique Building Identifier (UBID): Public Sector Implementation Guide

Buildings generate data throughout their lifecycle – about ownership & taxation, usage, zoning, code compliance, energy use, and retrofits. State and local governments collect this data after it flows through growing networks of people and systems. But collecting data is only half the battle; what’s really needed is information – the actionable insights that lead to successful policy outcomes.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Proceedings from the State of the Science and Technology for Minimizing Impacts to Bats from Wind Energy

The U.S. Department of Energy Wind Energy Technologies Office (DOE WETO), and the National Renewable Energy Laboratory convened a workshop entitled the State of the Science and Technology for Minimizing Impacts to Bats from Wind Energy on 13–14 November 2019. The objectives of the workshop were to (1) Identify the current impact minimization measures that are, or can be, used to reduce bat fatalities at wind energy facilities, (2) Assess the current effectiveness of those minimization measures, (3) Identify and assess the research and development (R&D) opportunities needed to optimize and improve the effectiveness of current minimization and deterrent technologies and inform the development of future solutions; and (4) Identify potential emerging or novel methods for informing impact minimization measures at or around wind energy facilities. Specifically, the workshop focused on deterrent and curtailment strategies. For deterrents, the discussion centered on the existing technology (i.e., ultrasonic deterrents, dim-UV light, and texture coating), integration with wind turbines (either retrofitting or out of the box installation), effectiveness, validation studies, and cost (e.g., technology, installation, validation, and maintenance). For curtailment, the conversation was divided into blanket curtailment (i.e., based on time and wind speed) and smart curtailment (i.e., blanket curtailment plus additional variables such as temperature or bat activity). The workshop included plenary presentations, panels, and breakout sessions to share data and stakeholder perspectives, and engage participants. Although there are several priority topics related to bat and wind energy, this workshop focused the discussion on the current technologies and strategies that are, or can be, used to reduce bat fatalities at wind energy facilities, status of research and development (R&D) of minimization measures, opportunities to optimize costs and improve effectiveness, and potential emerging or novel approaches to explore. This workshop took a holistic approach and discussed all aspects associated with advancing deterrent technologies and curtailment strategies, including the technological, biological, economic, and regulatory barriers faced by the wind energy and wildlife community.

13 HYDRO ENERGY↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ventilation in Residential Care Environments

The purpose of this study was to evaluate the effect of ventilation rate, directional airflow (e.g. pressure relationships) and airflow barriers on bioaerosol concentration and movement within assisted-living and residential care environments. Included within this report is a comprehensive literature review, field data collection test plan and, an evaluation of commercially available mitigation technologies related to the transmission of COVID-19 in LTC environments. Additionally, this report includes aerosol testing in an actual LTC facility using the test plan developed herein. Nearly 1.5 million people live in 16,000 nursing homes in the U.S. As of December 20, 2020 the Centers for Medicare and Medicaid Services (CMS) identified a total of 662,549 confirmed and suspected COVID-19 cases in these and other long-term care (LTC) facilities resulting in 92,373 deaths. At this time, COVID-19 cases in LTC facilities accounted for only 3% of the U.S. total of 21M confirmed cases yet nearly a third of the 350,000 total U.S. deaths. Preliminary studies have found little correlation between the quality of care and transmission of COVID-19 in these facilities, suggesting that even the best infection control practices may not be effective in containing the spread of this potentially airborne disease. As a result, many LTC facilities have implemented quarantine procedures and other measures to isolate infectious residents from the general population. Unfortunately, most LTC facilities were not designed for airborne infection control and guidance for retrofitting existing LTC spaces for airborne isolation is limited.

42 ENGINEERING↗

Regulatory Issues and Approaches to Municipal LED Street Lighting Conversions

Municipalities considering energy-efficient light-emitting diode street lights for their jurisdiction face a variety of regulatory issues. This brief describes how cities can successfully address these challenges to achieve multiple advantages. The brief first reviews the structure of street lighting tariffs and the costs and cost assumptions that underlie them. It then lays out pathways that municipalities can take to consider street lighting retrofits if faced by these regulatory barriers. The brief references cases of municipalities’ successes and challenges in pursuing these pathways. For more information, see the resources listed at the end of the brief.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗