Search NASA⌕ Search

SEARCH · Search NASA

Results for “STANDARDIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

SU-E-T-276: Dose Calculation Accuracy with a Standard Beam Model for Extended SSD Treatments

Purpose: While most photon treatments are delivered near 100cm SSD or less, a subset of patients may benefit from treatment at SSDs greater than 100cm. A proposed rotating chair for upright treatments would enable isocentric treatments at extended SSDs. The purpose of this study was to assess the accuracy of the Pinnacle{sup 3} treatment planning system dose calculation for standard beam geometries delivered at extended SSDs with a beam model commissioned at 100cm SSD. Methods: Dose to a water phantom at 100, 110, and 120cm SSD was calculated with the Pinnacle {sup 3} CC convolve algorithm for 6x beams for 5×5, 10×10, 20×20, and 30×30cm{sup 2} field sizes (defined at the water surface for each SSD). PDDs and profiles (depths of 1.5, 12.5, and 22cm) were compared to measurements in water with an ionization chamber. Point-by-point agreement was analyzed, as well as agreement in field size defined by the 50% isodose. Results: The deviations of the calculated PDDs from measurement, analyzed from depth of maximum dose to 23cm, were all within 1.3% for all beam geometries. In particular, the calculated PDDs at 10cm depth were all within 0.7% of measurement. For profiles, the deviations within the central 80% of the field were within 2.2% for all geometries. The field sizes all agreed within 2mm. Conclusion: The agreement of the PDDs and profiles calculated by Pinnacle3 for extended SSD geometries were within the acceptability criteria defined by Van Dyk (±2% for PDDs and ±3% for profiles). The accuracy of the calculation of more complex beam geometries at extended SSDs will be investigated to further assess the feasibility of using a standard beam model commissioned at 100cm SSD in Pinnacle3 for extended SSD treatments.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

SU-F-R-30: Interscanner Variability of Radiomics Features in Computed Tomography (CT) Using a Standard ACR Phantom

Purpose: A simple approach to investigate Interscanner variability of Radiomics features in computed tomography (CT) using a standard ACR phantom. Methods: The standard ACR phantom was scanned on CT scanners from three different manufacturers. Scanning parameters of 120 KVp, 200 mA were used while slice thickness of 3.0 mm on two scanners and 3.27 mm on third scanner was used. Three spherical regions of interest (ROI) from water, medium density and high density inserts were contoured. Ninety four Radiomics features were extracted using an in-house program. These features include shape (11), intensity (22), GLCM (26), GLZSM (11), RLM (11), and NGTDM (5) and 8 fractal dimensions features. To evaluate the Interscanner variability across three scanners, a coefficient of variation (COV) is calculated for each feature group. Each group is further classified according to the COV- by calculating the percentage of features in each of the following categories: COV less than 2%, between 2 and 10% and greater than 10%. Results: For all feature groups, similar trend was observed for three different inserts. Shape features were the most robust for all scanners as expected. 70% of the shape features had COV <2%. For intensity feature group, 2% COV varied from 9 to 32% for three scanners. All features in four groups GLCM, GLZSM, RLM and NGTDM were found to have Interscanner variability ≥2%. The fractal dimensions dependence for medium and high density inserts were similar while it was different for water inserts. Conclusion: We concluded that even for similar scanning conditions, Interscanner variability across different scanners was significant. The texture features based on GLCM, GLZSM, RLM and NGTDM are highly scanner dependent. Since the inserts of the ACR Phantom are not heterogeneous in HU values suggests that matrix based 2nd order features are highly affected by variation in noise. Research partly funded by NIH/NCI R01CA190105-01.

60 APPLIED LIFE SCIENCES↗

Standards for Sequencing Viral Genomes in the Era of High-Throughput Sequencing

Thanks to high-throughput sequencing technologies, genome sequencing has become a common component in nearly all aspects of viral research; thus, we are experiencing an explosion in both the number of available genome sequences and the number of institutions producing such data. However, there are currently no common standards used to convey the quality, and therefore utility, of these various genome sequences. Here, we propose five “standard” categories that encompass all stages of viral genome finishing, and we define them using simple criteria that are agnostic to the technology used for sequencing. We also provide genome finishing recommendations for various downstream applications, keeping in mind the cost-benefit trade-offs associated with different levels of finishing. Our goal is to define a common vocabulary that will allow comparison of genome quality across different research groups, sequencing platforms, and assembly techniques.

59 BASIC BIOLOGICAL SCIENCES↗

Determination of optical constants of a biaxially anisotropic film by standard multiangle monochromatic ellipsometry

Possibilities of standard multiangle monochromatic ellipsometry in the determination of parameters of a uniform biaxially anisotropic layer are studied for the case of an arbitrary orientation of the two principal axes in the plane of incidence of the light beam and perpendicularity of the third axis to the plane of incidence. Using numerical simulation, it has been found that the measurement accuracy that is necessary in the determination of all the three principal components of the dielectric permittivity tensor ε and tilt angle of the axes using only angular dependences of ellipsometric parameters must be no worse than 0.0001°, which is far beyond the accuracy limits provided by present-day ellipsometers. If the tilt angle is known, standard multiangle monochromatic ellipsometry provides the determination of thickness and all three principal components of the dielectric permittivity tensor. This method allows one to determine the layer thickness and tensor component for the axis perpendicular to the plane of incidence, as well as the average value of components for the axes lying in the plane of incidence without involving the data about the tilt angle of the axes. This is demonstrated by an example of experimental data for biaxially anisotropic SiO{sub x} films obtained by oblique deposition of silicon monoxide SiO evaporated in vacuum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of neutrons produced by muons in a standard rock

Characteristics of cosmogenic neutrons, such as the yield, production rate, and flux, were determined for a standard rock. The dependences of these quantities on the standard-rock depth and on the average muon energy were obtained. These properties and dependences make it possible to estimate easy the muon-induced neutron background in underground laboratories for various chemical compositions of rock.

58 GEOSCIENCES↗

Behaviors of impurity in ITER plasma with standard type I ELMy H-mode and steady-state scenarios

Self-consistent simulations of impurity behaviors in ITER plasmas in standard Type I ELMy H-mode and steady-state scenarios are investigated using 1.5D BALDUR integrated predictive modeling code. In these simulations, the plasma core transports, including electron and ion thermal, hydrogenic and impurity transports, are predicted using a linear combination of anomalous and neoclassical transports. An anomalous transport is calculated using a theory-based Multimode (MMM95) model; while the neoclassical transport is calculated using NCLASS model. The temperature and density boundary conditions are described at the top of the pedestal. Two different models for hydrogenic and impurity boundary density conditions are considered. The first model is called a 'static boundary density model,' in which the hydrogenic and impurity densities at the boundary are fixed. For the second model, called a 'dynamic boundary density model,' the hydrogenic and impurity densities at the boundary are assumed to be a large fraction of its line-averaged density. For simplicity, the pedestal temperature is assumed to be a constant in all simulations. The combination of a core transport model together with the boundary density models is used to simulate the time evolution of plasma current, temperature, and density profiles for ITER plasmas in standard type I ELMy H-mode and steady-state scenarios. As a result, the behaviors of impurity in ITER plasmas can be investigated. It is found in both ITER scenarios that the total amount of impurity, including beryllium and helium, in plasma core increases rapidly in early state and reaches a steady-state value. The level of impurity content in the steady state depends sensitively on the impurity boundary conditions. The effective charge at the edge is found to be about 1.4 and 1.1 using a static boundary density model and a dynamic boundary density model, respectively. It is also found that the hydrogenic and impurity transports in ITER plasmas for both scenarios is dominated by the kinetic ballooning modes, while the ITG and TEM modes provide the largest contributions for both thermal transports in most of region. In addition, a sensitivity study is carried out to investigate the impacts of pedestal temperature, pedestal density and line-averaged density on the impurity behaviors. It is found that increasing the pedestal temperature results in a reduction of the impurity content. On the other hand, increasing the pedestal density, line-averaged density or impurity influx result in an increase of the impurity content.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Search for physics beyond the standard model in events with τ leptons, jets, and large transverse momentum imbalance in pp collisions at $\sqrt{s}=7\ \mathrm{TeV}$

A search for physics beyond the standard model is performed with events having one or more hadronically decaying tau leptons, highly energetic jets, and large transverse momentum imbalance. The data sample corresponds to an integrated luminosity of 4.98 inverse femtobarns of proton-proton collisions at sqrt(s) = 7 TeV collected with the CMS detector at the LHC in 2011. The number of observed events is consistent with predictions for standard model processes. Lower limits on the mass of the gluino in supersymmetric models are determined.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks using a matrix element method

A search for a standard model Higgs boson produced in association with a top-quark pair and decaying to bottom quarks is presented. Events with hadronic jets and one or two oppositely charged leptons are selected from a data sample corresponding to an integrated luminosity of 19.5fb -1 collected by the CMS experiment at the LHC in pp collisions at a centre-of-mass energy of 8TeV. In order to separate the signal from the larger tt¯ + jets background, this analysis uses a matrix element method that assigns a probability density value to each reconstructed event under signal or background hypotheses. The ratio between the two values is used in a maximum likelihood fit to extract the signal yield. The results are presented in terms of the measured signal strength modifier, μ, relative to the standard model prediction for a Higgs boson mass of 125GeV. The observed (expected) exclusion limit at a 95 % confidence level is μ < 4.2 (3.3), corresponding to a best fit value μ^ = 1.2 +1.6 -1.5 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searches for physics beyond the standard model with the M T2 variable in hadronic final states with and without disappearing tracks in proton–proton collisions at $\sqrt{s}$ = 13 TeV

Two related searches for phenomena beyond the standard model (BSM) are performed using events with hadronic jets and significant transverse momentum imbalance. The results are based on a sample of proton-proton collisions at a center-of-mass energy of 13 TeV, collected by the CMS experiment at the LHC in 2016-2018 and corresponding to an integrated luminosity of 137 fb$^{-1}$. The first search is inclusive, based on signal regions defined by the hadronic energy in the event, the jet multiplicity, the number of jets identified as originating from bottom quarks, and the value of the kinematic variable $M_\mathrm{T2}$ for events with at least two jets. For events with exactly one jet, the transverse momentum of the jet is used instead. The second search looks in addition for disappearing tracks produced by BSM long-lived charged particles that decay within the volume of the tracking detector. No excess event yield is observed above the predicted standard model background. This is used to constrain a range of BSM models that predict the following: the pair production of gluinos and squarks in the context of supersymmetry models conserving $R$-parity, with or without intermediate long-lived charginos produced in the decay chain; the resonant production of a colored scalar state decaying to a massive Dirac fermion and a quark; or the pair production of scalar and vector leptoquarks each decaying to a neutrino and a top, bottom, or light-flavor quark. In most of the cases, the results obtained are the most stringent constraints to date.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for phenomena beyond the Standard Model in events with large $b$-jet multiplicity using the ATLAS detector at the LHC

A search is presented for new phenomena in events characterised by high jet multiplicity, no leptons (electrons or muons), and four or more jets originating from the fragmentation of b -quarks ( b -jets). The search uses 139 fb -1 of $\sqrt{s}$ = 13 TeV proton–proton collision data collected by the ATLAS experiment at the Large Hadron Collider during Run 2. The dominant Standard Model background originates from multijet production and is estimated using a data-driven technique based on an extrapolation from events with low b -jet multiplicity to the high b -jet multiplicities used in the search. No significant excess over the Standard Model expectation is observed and 95% confidence-level limits that constrain simplified models of R-parity-violating supersymmetry are determined. The exclusion limits reach 950 GeV in top-squark mass in the models considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Snowmass white paper: beyond the standard model effects on neutrino flavor

Neutrinos are one of the most promising messengers for signals of new physics Beyond the Standard Model (BSM). On the theoretical side, their elusive nature, combined with their unknown mass mechanism, seems to indicate that the neutrino sector is indeed opening a window to new physics. On the experimental side, several long-standing anomalies have been reported in the past decades, providing a strong motivation to thoroughly test the standard three-neutrino oscillation paradigm. In this Snowmass21 white paper, we explore the potential of current and future neutrino experiments to explore BSM effects on neutrino flavor during the next decade.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Searching for beyond the Standard Model physics using the improved description of 100 Mo $2\nu \beta \beta$ decay spectral shape with CUPID-Mo

The current experiments searching for neutrinoless double-β ($0\nu \beta \beta$) decay also collect large statistics of Standard Model allowed two-neutrino double-β ($2\nu \beta \beta$ ) decay events. These can be used to search for Beyond Standard Model (BSM) physics via $2\nu \beta \beta$ decay spectral distortions. 100 Mo has a natural advantage due to its relatively short half-life, allowing higher $2\nu \beta \beta$ decay statistics at equal exposures compared to the other isotopes. We demonstrate the potential of the dual read-out bolometric technique exploiting a 100 Mo exposure of 1.47 kg years, acquired in the CUPID-Mo experiment at the Modane underground laboratory (France). We set limits on $0\nu \beta \beta$ decays with the emission of one or more Majorons, on $2\nu \beta \beta$ decay with Lorentz violation, and $2\nu \beta \beta$ decay with a sterile neutrino emission. In this analysis, we investigate the systematic uncertainty induced by modeling the $2\nu \beta \beta$ decay spectral shape parameterized through an improved model, an effect never considered before. This work motivates searches for BSM processes in the upcoming CUPID experiment, which will collect the largest amount of $2\nu \beta \beta$ decay events among the next-generation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Search for Beyond the Standard Model physics with anomaly detection in multilepton final states in pp collisions at s=13TeV with the ATLAS detector

A model-agnostic search for Beyond the Standard Model physics is presented, targeting final states with at least four light leptons (electrons or muons). The search regions are separated by event topology and unsupervised machine learning is used to identify anomalous events in the full 140 fb-1$$^{-1}$$ of proton–proton collision data collected with the ATLAS detector during Run 2. No significant excess above the Standard Model background expectation is observed. Model-agnostic limits are presented in each topology, along with limits on several benchmark models including vector-like leptons, wino-like charginos and neutralinos, or smuons. Limits are set on the flavourful vector-like lepton model for the first time.

Aad, G↗

Domain-Wall Standard Model in non-compact 5D and LHC phenomenology

We propose a framework to construct “Domain-Wall Standard Model” in a non-compact 5-dimensional spacetime, where all the Standard Model (SM) fields are localized in certain domains of the 5th dimension and the SM is realized as a 4-dimensional effective theory without any compactification for the 5th dimension. In this context, we investigate the collider phenomenology of the Kaluza–Klein (KK) modes of the SM gauge bosons and the current constraints from the search for a new gauge boson resonance at the Large Hadron Collider Run-2. The couplings of the SM fermions with the KK-mode gauge bosons depend on the configuration of the SM fermions in the 5-dimensional bulk. This “geometry” of the model can be tested at the future Large Hadron Collider experiment, once a KK-mode of the SM gauge boson is discovered.

Astronomy & Astrophysics↗

Standard Energy Efficiency Data Platform® [SWR-17-25]

The Standard Energy Efficiency Data Platform® (SEED Platform) provides public agencies and other organizations with a standardized but flexible, cost-effective, secure, enterprise data platform to manage portfolio scale building performance data from a variety of sources. The SEED Platform streamlines the administrative effort required by public agencies implementing building performance and transparency programs.

Source record↗

sssmatch (Standard ScenarioS Match)

The standard scenarios match (sssmatch) tool accepts limited information about an existing transmission system model and computes a new generation mix based on a.) matching a particular NREL Standard Scenario generation mix and b.) minimizing the distance between the system’s original mix and the final one. The distance metric is computed on a nodal basis.

Duckworth, Jonathan↗

ENDF/B-VIII.1: Neutron Standards Sublibrary

The neutron standards sublibrary describes specific reaction cross sections, in a limited range, that are so well-known that they are used as ratios or references in other measurements. ENDF/B-VIII.1 remains unchanged from ENDF/B-VIII.0 for the neutron standards sublibrary

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗