Search NASA⌕ Search

SEARCH · Search NASA

Results for “Software studies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

SU-E-T-422: Correlation Between 2D Passing Rates and 3D Dose Differences for Pretreatment VMAT QA

Purpose: Volumetric modulated arc therapy (VMAT) quality assurance (QA) is typically using QA methods and action levels taken from fixedbeam intensity-modulated radiotherapy (IMRT) QA methods. However, recent studies demonstrated that there is no correlation between the percent gamma passing rate (%GP) and the magnitude of dose discrepancy between the planned dose and the actual delivered dose for IMRT. The purpose of this study is to investigate whether %GP is correlated with clinical dosimetric difference for VMAT. Methods: Twenty nasopharyngeal cancer (NPC) patients treated with dual-arc simultaneous integrated boost VMAT and 20 esophageal cancer patients treated with one-arc VMAT were enrolled in this study. Pretreatment VMAT QA was performed by a 3D diode array ArcCheck. Acceptance criteria of 2%/2mm, 3%/3mm, and 4%/4mm were applied for 2D %GP. Dose values below 10% of the per-measured normalization maximum dose were ignored.Mean DVH values obtained from 3DVH software and TPS were calculated and percentage dose differences were calculated. Statistical correlation between %GP and percent dose difference was studied by using Pearson correlation. Results: The %GP for criteria 2%/2mm, 3%/3mm, and 4%/4mm were 82.33±4.45, 93.47±2.31, 97.13±2.41, respectively. Dose differences calculated from 3DVH and TPS for beam isocenter, mean dose of PTV, maximum dose of PTV, D2 of PTV and D98 of PTV were -1.04±3.24, -0.74±1.71, 2.92±3.62, 0.89±3.29, -1.46±1.97, respectively. No correction were found between %GP and dose differences. Conclusion: There are weak correlations between the 2D %GP and dose differences calculated from 3DVH. The %GP acceptance criteria of 3%/3mm usually applied for pretreatment QA of IMRT and VMAT is not indicating strong clinical correlation with 3D dose difference. 3D dose reconstructions on patient anatomy may be necessary for physicist to predict the accuracy of delivered dose for VMAT QA.

60 APPLIED LIFE SCIENCES↗

Focal Gray Matter Plasticity as a Function of Long Duration Head Down Tilted Bed Rest: Preliminary Results

Long duration spaceflight (i.e., 22 days or longer) has been associated with changes in sensorimotor systems, resulting in difficulties that astronauts experience with posture control, locomotion, and manual control. The microgravity environment is an important causal factor for spaceflight induced sensorimotor changes. Whether these sensorimotor changes are solely related to peripheral changes from reduced vestibular stimulation, body unloading, body fluid shifts or that they may be related to structural and functional brain changes is yet unknown. However, a recent study reported associations between microgravity and flattening of the posterior eye globe and protrusion of the optic nerve [1] possibly as the result of increased intracranial pressure due to microgravity induced bodily fluid shifts [3]. Moreover, elevated intracranial pressure has been related to white matter microstructural damage [2]. Thus, it is possible that spaceflight may affect brain structure and thereby cognitive functioning. Long duration head down tilt bed rest has been suggested as an exclusionary analog to study microgravity effects on the sensorimotor system [4]. Bed rest mimics microgravity in body unloading and bodily fluid shifts. In consideration of the health and performance of crewmembers both in- and post-flight, we are conducting a prospective longitudinal 70-day bed rest study as an analog to investigate the effects of microgravity on brain structure [5]. Here we present results of the first six subjects. Six subjects were assessed at 12 and 7 days before-, at 7, 30, and ~70 days in-, and at 8 and 12 days post 70 days of bed rest at the NASA bed rest facility in UTMB, Galveston, TX, USA. At each time point structural MRI scans (i.e., high resolution T1-weighted imaging and Diffusion Tensor Imaging (DTI)) were obtained using a 3T Siemens scanner. Focal changes over time in gray matter density were assessed using the voxel based morphometry 8 (VBM8) toolbox under SPM. Longitudinal processing in VBM8 includes linear registration of each scan to the mean of the subject and subsequently transforming all scans in to MNI space by applying the warp from the mean subject to MNI to the individual gray matter segmentations. Modulation was applied so that all images represented the volume of the original structure in native space. Voxel wise analysis was carried out on the gray matter images after smoothing, using a flexible factorial design with family wise error correction. Focal changes in white matter microstructural integrity were assessed using tract based spatial statistics (TBSS) as part of FMRIB software library (FSL). TBSS registers all DTI scans to standard space. It subsequently creates a study specific white matter skeleton of the major white matter tracts. For each subject, for each DTI metric (i.e. fractional anisotropy (FA), mean diffusivity (MD), axial diffusivity (AD), and radial diffusivity (RD)), the maximum value in a line perpendicular to the skeleton tract is projected to the skeleton. Non-parametric permutation based t-tests and ANOVA's were used for voxel-wise comparison of the skeletons. For both VBM and TBSS, comparison of pre bed rest measurements did not show significant differences. VBM analysis revealed decreased gray matter density in bilateral areas including the frontal medial cortex, the insular cortex and the caudate (see Figure) from 'pre to in bed rest'. Over the same time period, there was an increase in gray matter density in the cerebellum, occipital-, and parietal cortex, including the precuneus (see Figure). The majority of these changes did not recover from 'during to post bed rest'. TBSS analysis did not reveal significant changes in white matter microstructural integrity after correction for multiple comparisons. Uncorrected analyses (p<.015) revealed an increase in RD in the cerebellum and brainstem from pre bed rest to the first week in bed rest that did not recover post bed rest. Extended bed rest, which is an analog for microgravity, can result in gray matter changes and potentially in microstructural white matter changes in areas that are important for neuro motor behavior and cognition. These changes did not recover at two weeks post bed rest. Whether the effects of bed rest wear off at longer times post bed rest, and if they are associated with behavior are important questions that warrant further research.

Koppelmans, V.↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Data Processing for the SNS EQ-SANS Diffractometer

The scattering data on the Extended Q-Range Small Angle Scattering Diffractometer at the Spallation Neutron Source are stored as neutron events. Each event has two parts: the time of fight of the detected neutron, and an identifier for the neutron's location on the detector. In addition, each event is associated with the source pulse from which the neutron is originated. Due to the high neutron beam intensity at the SNS, the size of the stored data files can easily exceed several Gigabytes. Processing and reducing these data can be very time consuming. The standard way of handling the data at the SNS has been to first transform the data into histograms. On the EQ-SANS, these histograms are further processed into intensity I vs. neutron momentum transfer Q files, I(Q). For a large data, the whole process can take many minutes to hours to complete, which severely limits the turnaround time of an experiment. Experimenters often want to reduce the data quickly and depending on the result, make decisions on the setup of next measurements. They may also need to reduce the data using different inputs and conditions. In this work, we present the implementation of a fast data processing scheme for the EQ-SANS diffractometer. The scattering data are processed directly from neutron event files into I(Q) or other desired formats, greatly reducing the needed computation time. Further speed gains are obtained by the implementation of parallel computing under the Message Passing Interface framework. Most data on the EQ-SANS can now be handled in mere seconds. The process is highly automated. All relevant experimental information that is stored in instrument configuration files are read and processed. In addition, the new implementation is highly flexible. All the data corrections and handlings can be controlled transparently through user inputs. Finally, software implementation enables the slicing of neutron event, which can be used for the study of time dependent phenomena.

Data Processing↗

An S-band high gain relativistic klystron amplifier with high phase stability

For the purpose of coherent high power microwave combining, an S-band high gain relativistic klystron amplifier with high phase stability is presented and studied. By the aid of 3D particle-in-cell code and circuit simulation software, the mechanism of parasitic oscillation in the device is investigated. And the RF lossy material is adopted in the simulation and experiment to suppress the oscillation. The experimental results show that with an input RF power of 10 kW, a microwave pulse with power of 1.8 GW is generated with a gain of 52.6 dB. And the relative phase difference fluctuation between output microwave and input RF signal is less than ±10° in 90 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SHAD: the Scalable High-performance Algorithms and Data-structures Library

The unprecedented amount of data that needs to be processed in emerging data analytics applications poses novel challenges to industry and academia. Scalability and high performance become more than a desirable feature because, due to the scale and the nature of the problems, they draw the line between what is achievable and what is unfeasible. In this paper, we propose SHAD, the Scalable High-performance Algorithms and Data-structures library. SHAD adopts a modular design that confines low level details and promotes reuse. SHAD's core is built on an Abstract Runtime Interface which enhances portability and identifies the minimal set of features of the underlying system required by the framework. The core library includes common data-structures such as: Array, Vector, Map and Set. These are designed to accommodate significant amount of data which can be accessed in massively parallel environments, and used as building blocks for SHAD extensions, i.e. higher level software libraries. We have validated and evaluated our design with a performance and scalability study of the core components of the library. We have validated the design flexibility by proposing a Graph Library as an example of SHAD extension, which implements two different graph data-structures; we evaluate their performance with a set of graph applications. Experimental results show that the approach is promising in terms of both performance and scalability. On a distributed system with 320 cores, SHAD Arrays are able to sustain a throughput of 65 billion operations per second, while SHAD Maps sustain 1 billion of operations per second. Algorithms implemented using the Graph Library exhibit performance and scalability comparable to a custom solution, but with smaller development effort.

Castellana, Vito G.↗

GS3: A Knowledge Management Architecture for Collaborative Geologic Sequestration Modeling

Modern scientific enterprises are inherently knowledge-intensive. In general, scientific studies in domains such as groundwater, climate, and other environmental modeling as well as fundamental research in chemistry, physics, and biology require the acquisition and manipulation of large amounts of experimental and field data in order to create inputs for large-scale computational simulations. The results of these simulations must then be analyzed, leading to refinements of inputs and models and further simulations. In this paper we describe our efforts in creating a knowledge management platform to support collaborative, wide-scale studies in the area of geologic sequestration. The platform, known as GS3 (Geologic Sequestration Software Suite), exploits and integrates off-the-shelf software components including semantic wikis, content management systems and open source middleware to create the core architecture. We then extend the wiki environment to support the capture of provenance, the ability to incorporate various analysis tools, and the ability to launch simulations on supercomputers. The paper describes the key components of GS3 and demonstrates its use through illustrative examples. We conclude by assessing the suitability of our approach for geologic sequestration modeling and generalization to other scientific problem domains

58 GEOSCIENCES↗

Evaluation of clip localization for different kilovoltage imaging modalities as applied to partial breast irradiation setup

Surgical clip localization and image quality were evaluated for different types of kilovoltage cone beam imaging modalities as applied to partial breast irradiation (PBI) setup. These modalities included (i) clinically available radiographs and cone beam CT (CB-CT) and (ii) various alternative modalities based on partial/sparse/truncated CB-CT. An anthropomorphic torso-breast phantom with surgical clips was used for the imaging studies. The torso phantom had artificial lungs, and the attached breast phantom was a mammographic phantom with realistic shape and tissue inhomogeneities. Three types of clips of variable size were used in two orthogonal orientations to assess their in-/cross-plane characteristics for image-guided setup of the torso-breast phantom in supine position. All studies were performed with the Varian on-board imaging (OBI, Varian) system. CT reconstructions were calculated with the standard Feldkamp-Davis-Kress algorithm. First, the radiographs were studied for a wide range of viewing angles to characterize image quality for various types of body anatomy in the foreground/background of the clips. Next, image reconstruction quality was evaluated for partial/sparse/truncated CB-CT. Since these modalities led to reconstructions with strong artifacts due to insufficient input data, a knowledge-based CT reconstruction method was also tested. In this method, the input data to the reconstruction algorithm were modified by combining complementary data sets selected from the treatment and reference projections. Different partial/sparse/truncated CB-CT scan types were studied depending on the total arc angle, angular increment between the consequent views (CT projections), orientation of the arc center with respect to the imaged breast and chest wall, and imaging field size. The central angles of the viewing arcs were either tangential or orthogonal to the chest wall. Several offset positions of the phantom with respect to the reference position were studied. The acquired and reconstructed image data sets were analyzed using home-built software focusing on the ability to localize clips in 3D. Streaking and leakage reconstruction artifacts and spatial distortions of breast surface were analyzed as well. Advantages and disadvantages of each kilovoltage CB imaging modality as applied to partial breast setup evaluation based on clips are presented. Because clips were found to be difficult to recognize in radiographs, 3D reconstructions were preferred. Even though it was possible to localize clips with about {+-}1 mm accuracy based on reconstructions for short arcs of 40 deg. and incremental angle up to about 5 deg., identification of clips in such reconstructions is difficult. Reconstructions obtained for arcs of as low as 80 deg. and incremental angle of as high as 3 deg. were suggested for easier clip identification. For more severely undersampled data, iterative CB-CT reconstruction is recommended to decrease the artifacts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-644: Evaluation of Angular Dependence Correction for 2D Array Detector Using for Quality Assurance of Volumetric Modulated Arc Therapy

Purpose: To evaluate the angular dependence correction for Matrix Evolution 2D array detector in quality assurance of volumetric modulated arc therapy(VMAT). Methods: Total ten patients comprising of different sites were planned for VMAT and taken for the study. Each plan was exposed on Matrix Evolution 2D array detector with Omnipro IMRT software based on the following three different methods using 6MV photon beams from Elekta Synergy linear accelerator. First method, VMAT plan was delivered on Matrix Evolution detector as it gantry mounted with dedicated holder with build-up of 2.3cm. Second, the VMAT plan was delivered with the static gantry angle on to the table mounted setup. Third, the VMAT plan was delivered with actual gantry angle on Matrix Evolution detector fixed in Multicube phantom with gantry angle sensor and angular dependence correction were applied to quantify the plan quality. For all these methods, the corresponding QA plans were generated in TPS and the dose verification was done for both point and 2D fluence analysis with pass criteria of 3% dose difference and 3mm distance to agreement. Results: The measured point dose variation for the first method was observed as 1.58±0.6% of mean and SD with TPS calculated. For second and third method, the mean and standard deviation(SD) was observed as 1.67±0.7% and 1.85±0.8% respectively. The 2D fluence analysis of measured and TPS calculated has the mean and SD of 97.9±1.1%, 97.88±1.2% and 97.55±1.3% for first, second and third methods respectively. The calculated two-tailed Pvalue for point dose and 2D fluence analysis shows the insignificance with values of 0.9316 and 0.9015 respectively, among the different methods of QA. Conclusion: The qualitative evaluation of angular dependence correction for Matrix Evolution 2D array detector shows its competency in accuracy of quality assurance measurement of composite dose distribution of volumetric modulated arc therapy.

07 ISOTOPE AND RADIATION SOURCES↗

CyGutz

This software is an efficient computational package of the Gutzwiller variational method. It solves the Gutzwiller variational problem for general multiband models with arbitrary on-site interaction in a fully self-consistent numerical approach. The underlying algorithm drastically reduces the problem of the high-dimensional Gutzwiller minimization by mapping it to a minimization only in the variational density matrix. For fixed density the Gutzwiller renormalization matrix is determined as a fix-point of a proper functional, whose evaluation requires only ground-state calculations of matrices defined in the Gutzwiller variational space. Furthermore, the package is able to account for the symmetries of the variational function in a controlled way, reducing the number of variational parameters. The software is highly efficient and robust, and is particularly suitable for first-principles studies (e.g., in combination with DFT) of many complex real materials, where the full intra-atomic interaction is important to obtain correct results.

Yao, Yongxin↗

Scheduler Modeling of IBR Plants for Providing Ancillary Services [SWR-25-16]

Inverter-based resources (IBRs) have been integral components of modern power systems and their capability in providing grid services have been widely studied. To promote the deployment of IBR grid services in real utility operation, this software proposes a scheduler model for IBRs. The energy and reserve are co-optimized in day-ahead, various ancillary services, including operating reserve provision, peak load reduction, voltage regulation and power factor control are integrated in the model.

Wang, Xiaofei [National Renewable Energy Laborator↗

Evaluating Operating System Vulnerability to Memory Errors

Reliability is of great concern to the scalability of extreme-scale systems. Of particular concern are soft errors in main memory, which are a leading cause of failures on current systems and are predicted to be the leading cause on future systems. While great effort has gone into designing algorithms and applications that can continue to make progress in the presence of these errors without restarting, the most critical software running on a node, the operating system (OS), is currently left relatively unprotected. OS resiliency is of particular importance because, though this software typically represents a small footprint of a compute node's physical memory, recent studies show more memory errors in this region of memory than the remainder of the system. In this paper, we investigate the soft error vulnerability of two operating systems used in current and future high-performance computing systems: Kitten, the lightweight kernel developed at Sandia National Laboratories, and CLE, a high-performance Linux-based operating system developed by Cray. For each of these platforms, we outline major structures and subsystems that are vulnerable to soft errors and describe methods that could be used to reconstruct damaged state. Our results show the Kitten lightweight operating system may be an easier target to harden against memory errors due to its smaller memory footprint, largely deterministic state, and simpler system structure.

99 GENERAL AND MISCELLANEOUS↗

A journey from nuclear criticality methods to high energy density radflow experiments

Los Alamos National Laboratory is a nuclear weapons laboratory supporting our nation's defense. In support of this mission is a high energy-density physics program in which we design and execute experiments to study radiationhydrodynamics phenomena and improve the predictive capability of our largescale multi-physics software codes on our big-iron computers. The Radflow project’s main experimental effort now is to understand why we haven't been able to predict opacities on Sandia National Laboratory's Z-machine. We are modeling an increasing fraction of the Z-machine's dynamic hohlraum to find multi-physics explanations for the experimental results. Further, we are building an entirely different opacity platform on Lawrence Livermore National Laboratory's National Ignition Facility (NIF), which is set to get results early 2017. Will the results match our predictions, match the Z-machine, or give us something entirely different? The new platform brings new challenges such as designing hohlraums and spectrometers. The speaker will recount his history, starting with one-dimensional Monte Carlo nuclear criticality methods in graduate school, radiative transfer methods research and software development for his first 16 years at LANL, and, now, radflow technology and experiments. Who knew that the real world was more than just radiation transport? Experiments aren't easy and they are as saturated with politics as a presidential election, but they sure are fun.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A journey from nuclear criticality methods to high energy density radflow experiments

Los Alamos National Laboratory is a nuclear weapons laboratory supporting our nation's defense. In support of this mission is a high energy-density physics program in which we design and execute experiments to study radiationhydrodynamics phenomena and improve the predictive capability of our largescale multi-physics software codes on our big-iron computers. The Radflow project’s main experimental effort now is to understand why we haven't been able to predict opacities on Sandia National Laboratory's Z-machine. We are modeling an increasing fraction of the Z-machine's dynamic hohlraum to find multi-physics explanations for the experimental results. Further, we are building an entirely different opacity platform on Lawrence Livermore National Laboratory's National Ignition Facility (NIF), which is set to get results early 2017. Will the results match our predictions, match the Z-machine, or give us something entirely different? The new platform brings new challenges such as designing hohlraums and spectrometers. The speaker will recount his history, starting with one-dimensional Monte Carlo nuclear criticality methods in graduate school, radiative transfer methods research and software development for his first 16 years at LANL, and, now, radflow technology and experiments. Who knew that the real world was more than just radiation transport? Experiments aren't easy, but they sure are fun.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Final LDRD Report: Using Linkography of Cyber Attack Patterns to Inform Honeytoken Placement

The war to establish cyber supremacy continues, and the literature is crowded with strictly technical cyber security measures. We present the results of a three year LDRD project using Linkography, a methodology new to the field of cyber security, we establish the foundation necessary to track and profile the microbehavior of humans attacking cyber systems. We also propose ways to leverage this understanding to influence and deceive these attackers. We studied the science of linkography, applied it to the cyber security domain, implemented a software package to manage linkographs, generated the preprocessing blocks necessary to ingest raw data, produced machine learning models, created ontology refinement algorithms and prototyped a web application for researchers and practitioners to apply linkography. Machine learning produced some of our key results: We trained and validated multinomial classifiers with a real world data set and predicted the attacker's next category of action with 86 to 98% accuracy; dimension reduction techniques indicated that the linkography-based features were among the most powerful. We also discovered ontology refinement algorithms that advanced the state of the art in linkography in general and cyber security in particular. We conclude that linkography is a viable tool for cyber security; we look forward to expanding our work to other data sources and using our prediction results to enable adversary deception techniques.

97 MATHEMATICS AND COMPUTING↗

TChem v2.0 - A Software Toolkit for the Analysis of Complex Kinetic Models

TChem is an open source software library for solving complex computational chemistry problems and analyzing detailed chemical kinetic models. The software provides support for: complex kinetic models for gas-phase and surface chemistry; thermodynamic properties based on NASA polynomials; species production/consumption rates; stable time integrator for solving stiff time ordinary differential equations; and, reactor models such as homogenous gas-phase ignition (with analytical Jacobian matrices), continuously stirred tank reactor, plug-flow reactor. This toolkit builds upon earlier versions that were written in C and featured tools for gas-phase chemistry only. The current version of the software was completely refactored in C++, uses an object-oriented programming model, and adopts Kokkos as its portability layer to make it ready for the next generation computing architectures i.e., multi/many core computing platforms with GPU accelerators. We have expanded the range of kinetic models to include surface chemistry and have added examples pertaining to Continuously Stirred Tank Reactors (CSTR) and Plug Flow Reactor (PFR) models to complement the homogenous ignition examples present in the earlier versions. To exploit the massive parallelism available from modern computing platforms, the current software interface is designed to evaluate samples in parallel, which enables large scale parametric studies, e.g. for sensitivity analysis and model calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi‐Decadal Decarbonization Pathways for U.S. Freight Rail

A‐STEP is a first‐of‐its‐kind, integrated, open‐source software tool aimed at guiding freight rail decarbonization decision‐making. It has tools for studying energy use details for individual trains, networks of trains, battery and hydrogen charging stations, national energy sourcing and pricing, and overall decarbonization costs and environmental impacts. It gives analysts an ability to study the challenges of making such change happen. Completely amenable to analyst specified inputs and parameter values, it can be customized to provide outputs for a wide variety of assumptions about future energy conditions and technological advances. Written in Python, C++, and VB.Net, A‐STEP can be implemented on both Windows and Linux‐based platforms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Studies on Printability Methodologies and Directed-Energy-Deposition-Fabricated Iron Alloys for Nuclear Applications

This report provides results from a printability study of laser directed energy deposition (DED)-based additive manufacturing of nuclear-grade stainless steels as well as DED process parameter development for austenitic Alloy 709 (A709) and ferritic/martensitic Grade 91 (G91) and Grade 92 (G92) steels. The printability study includes the use of machine learning and physics-based modeling via commercial software such as FLOW-3D for insights into the impact of the alloy composition, particularly the carbon content, on the printability of stainless steels during the DED process. In the DED process development work, 1 cm 3 alloy blocks were deposited with broad ranges of laser powers, scan speeds, and hatch spacings to optimize the build quality, resulting in densities of more than 99.8% for all three alloys. The microstructure and mechanical properties were characterized using electron microscopy, X-ray diffraction, and Vickers hardness measurements. Further, tensile samples were extracted from DED-fabricated alloys utilizing the optimized process parameters. The present work provides guidance and progress towards the successful deployment of the DED process for the fabrication of structural components of nuclear reactors.

36 MATERIALS SCIENCE↗