Using Cosmic Ray Muons to Assess Geological Characteristics in the Subsurface
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
This is a technical presentation that does not take into account contractual limitations or obligations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). For example, under the provisions of the Standard Contract, spent nuclear fuel in multi-assembly canisters is not an acceptable waste form, absent a mutually agreed to contract amendment.
The overarching goal of OU’s contribution to the project was to use novel computational approaches to quantify the effect of variable nanopore features (pore size, volume, topology, and chemistry) and the presence of water or salt solutions on the sorption and transport of carbon-bearing fluids. To achieve this goal OU collaborators tested test two related hypotheses: • The transport of water and aqueous electrolytes in nanopores is controlled by pore size, pore wall composition, and the type of salt – structure-maker (e.g., CaCl 2 ) versus structure-breaker (e.g., NaCl) that affect the hydrogen-bonding network. • The structure, solubility, and transport of carbon-bearing molecules in water or aqueous electrolyte-filled nanopores are controlled by the substrate type including degree of hydration, and pore features, and regulated by the hydration structure of the guest molecules.
Explore the source record for details and available documents.
Conference abstract
Explore the source record for details and available documents.
This study evaluated offshore carbon sequestration potential and infrastructure design along the mid-north Atlantic outer continental shelf, addressing the limited onshore storage options in the northeastern U.S. The objective was to define viable CCS pathways by integrating geological characterization, reservoir modeling, and system-level engineering for decarbonizing regional industrial sources. The work was conducted under US DOE grant FE0032407 for the Regional Initiatives and builds on a previous prospective resources assessment project by Battelle.
Groundwater monitoring is essential to timely and accurately reflect the current situations and the trends of water quality. However, the long-term stability and survival of any potential in-situ monitoring method is threatened by the harsh conditions and the groundwater monitoring in downhole environments poses numerous challenges to the sensor community. Laser induced breakdown spectroscopy (LIBS) has been demonstrated as a promising technology for chemical monitoring in high-temperature high-pressure (HTHP) environments and hard to reach places. The technique demonstrates several advantages, such as rapid, real-time, in-situ, and simultaneous detection of multiple elements with simple or no sample preparation. This chapter includes a brief review of the field-portable LIBS systems, and development of a compact, robust, and simple LIBS instrument for downhole HTHP water quality monitoring. The fieldable prototype sensor is tested in an onsite monitoring well where trace elements’ concentrations are tracked over an extended period. The testing has verified that the fiber coupled design performs as desired. The system shows good calibration linearity for tested elements and collection times, and Limits of Detection (LODs) that are comparable to those of tabletop LIBS instruments. In addition to groundwater quality monitoring, the fabricated LIBS-based sensor could have widespread sub-surface detection applications.
A thesis submitted to the Graduate Faculty of Auburn University in partial fulfillment of the requirements for the Degree of Master of Science
Modern engineered containment systems used at landfills and other waste disposal sites are designed to isolate municipal, industrial, and hazardous wastes and to prevent contaminated leachates and gases from escaping into the environment. The two primary questions posed in this study were: How well are these engineered barrier systems working? How long are they likely to work effectively? Up to 20 years of field observations suggest that engineered waste containment barrier systems that are designed, constructed, operated, and maintained in accordance with current statutory regulations and requirements have so far provided environmental protection at or above specified levels. However, these barriers have not been in existence long enough to assess long-term (post closure) performance for periods that may need to extend for hundreds of years. Much of the available data are from monitoring the environment downstream of the barrier, and there is little direct monitoring of the barriers themselves. New monitoring techniques, expanded collection and reporting of data and periodic assessments of barrier system effectiveness are needed to further increase confidence in barrier system performance.
No abstract prepared.
Engineers and technicians at the Idaho National Laboratory invented, designed, built and tested a device capable of detecting and measuring the distance to, an underground void, or tunnel. Preliminary tests demonstrated positive detection of, and range to, a void thru as much as 30 meters of top-soil earth. Device uses acoustic driving point impedance principles pioneered by the Laboratory for well-bore physical properties logging. Data receipts recorded by the device indicates constructive-destructive interference patterns characteristic of acoustic wave reflection from a downward step-change in impedance mismatch. Prototype tests demonstrated that interference patterns in receipt waves could depict the patterns indicative of specific distances. A tool with this capability can quickly (in seconds) indicate the presence and depth/distance of a void or tunnel. Using such a device, border security and military personnel can identify threats of intrusion or weapons caches in most all soil conditions including moist and rocky.
We describe our experiences running PFLOTRAN - a code for simulation of coupled hydro-thermal-chemical processes in variably saturated, non-isothermal, porous media - on leadership-class supercomputers, including initial experiences running on the petaflop incarnation of Jaguar, the Cray XT5 at the National Center for Computational Sciences at Oak Ridge National Laboratory. PFLOTRAN utilizes fully implicit time-stepping and is built on top of the Portable, Extensible Toolkit for Scientific Computation (PETSc). We discuss some of the hurdles to 'at scale' performance with PFLOTRAN and the progress we have made in overcoming them on leadership-class computer architectures.
A field facility located in Bozeman, Montana provides the opportunity to test methods to detect, locate, and quantify potential CO2 leakage from geologic storage sites. From 9 July to 7 August 2008, 0.3 t CO2 d{sup -1} were injected from a 100-m long, {approx}2.5 m deep horizontal well. Repeated measurements of soil CO2 fluxes on a grid characterized the spatio-temporal evolution of the surface leakage signal and quantified the surface leakage rate. Infrared CO2 concentration sensors installed in the soil at 30 cm depth at 0 to 10 m from the well and at 4 cm above the ground at 0 and 5 m from the well recorded surface breakthrough of CO2 leakage and migration of CO2 leakage through the soil. Temporal variations in CO2 concentrations were correlated with atmospheric and soil temperature, wind speed, atmospheric pressure, rainfall, and CO2 injection rate.
A recent review found several conflicting conclusions regarding colloid-facilitated transport of radionuclides in groundwater and noted that colloids can both facilitate and retard transport. Given these contrasting conclusions and the profound implications even trace concentrations of plutonium (Pu) have on the calculated risk posed to human health, it is important that the methodology used to sample groundwater colloids be free of artifacts. The objective of this study was: (1) to conduct a field study and measure Pu speciation, ({sup 239}Pu and {sup 240}Pu for reduced-Pu{sub aq}, oxidized-Pu{sub aq}, reduced-Pu{sub colloid}, and oxidized-Pu{sub colloid}), in a Savannah River Site (SRS) aquifer along a pH gradient in F-Area, (2) to determine the impact of pumping rate on Pu concentration, Pu speciation, and Pu isotopic ratios, (3) determine the impact of delayed sample processing (as opposed to processing directly from the well).