Search NASA⌕ Search

SEARCH · Search NASA

Results for “Testing Standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Higher certainty of the laser-induced damage threshold test with a redistributing data treatment

As a consequence of its statistical nature, the measurement of the laser-induced damage threshold holds always risks to over- or underestimate the real threshold value. As one of the established measurement procedures, the results of S-on-1 (and 1-on-1) tests outlined in the corresponding ISO standard 21 254 depend on the amount of data points and their distribution over the fluence scale. With the limited space on a test sample as well as the requirements on test site separation and beam sizes, the amount of data from one test is restricted. This paper reports on a way to treat damage test data in order to reduce the statistical error and therefore measurement uncertainty. Three simple assumptions allow for the assignment of one data point to multiple data bins and therefore virtually increase the available data base.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Preparation and Characterization of Co–Ni Nanoparticles and the Testing of a Heterogenized Co–Ni/Alumina Catalyst for CO Hydrogenation

Samples of well-controlled nanoparticles consisting of alloys of cobalt and nickel of different atomic ratios were synthesized using wet chemical methods with oleylamine as the solvent and the reducing agent. These materials were characterized by a variety of techniques, including high-angle annular dark-field scanning transmission electron microscopy (HAADF-STEM), X-ray energy dispersive spectroscopy (EDS), and X-ray diffraction (XRD). Small amounts of heterogenized catalysts were prepared using alumina as the support. However, the potential for use of Co–Ni catalysts in CO hydrogenation was explored using a larger amount of Co–Ni/alumina catalyst prepared from standard aqueous impregnation methods and tested in a continuously stirred tank reactor (CSTR) for Fischer–Tropsch synthesis (FTS). Results are compared to a reference catalyst containing only cobalt. The heterogenized catalysts were characterized using synchrotron methods, including temperature programmed reduction with extended X-ray absorption fine structure spectroscopy and X-ray absorption near edge spectroscopy (TPR-EXAFS/XANES). The characterization results support intimate contact between Co and Ni, strongly suggesting alloy formation. In FTS testing, drawbacks of Ni addition included decreased CO conversion on a per gram catalyst basis, although Ni did not significantly impact the turnover number of cobalt, and produced slightly higher light gas selectivity. Benefits of Ni addition included an inverted induction period relative to undoped Co/Al2O3, where CO conversion increased with time on-stream in the initial period, and the stabilization of cobalt nanoparticles at a lower weight % of Co.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparison of cosmological models using time delay lenses

The use of time-delay gravitational lenses to examine the cosmological expansion introduces a new standard ruler with which to test theoretical models. The sample suitable for this kind of work now includes 12 lens systems, which have thus far been used solely for optimizing the parameters of ΛCDM. In this paper, we broaden the base of support for this new, important cosmic probe by using these observations to carry out a one-on-one comparison between competing models. The currently available sample indicates a likelihood of ∼70%-80% that the R {sub h} = ct universe is the correct cosmology versus ∼20%-30% for the standard model. This possibly interesting result reinforces the need to greatly expand the sample of time-delay lenses, e.g., with the successful implementation of the Dark Energy Survey, the VST ATLAS survey, and the Large Synoptic Survey Telescope. In anticipation of a greatly expanded catalog of time-delay lenses identified with these surveys, we have produced synthetic samples to estimate how large they would have to be in order to rule out either model at a ∼99.7% confidence level. We find that if the real cosmology is ΛCDM, a sample of ∼150 time-delay lenses would be sufficient to rule out R {sub h} = ct at this level of accuracy, while ∼1000 time-delay lenses would be required to rule out ΛCDM if the real universe is instead R {sub h} = ct. This difference in required sample size reflects the greater number of free parameters available to fit the data with ΛCDM.

79 ASTRONOMY AND ASTROPHYSICS↗

Standard operating procedure for post-operation component disassembly and observation of benchtop water electrolyzer testing

Post-operation component disassembly and observation of electrolyzer parts is useful in understanding the interactions of the components and the electrochemical environment beyond the systems electrochemical output. We report a standard protocol for post-operation component disassembly and observation, including directions for cell-component preservation, preliminary visual inspection of cell components, and a guide for the advanced inspection of specific components with suggestions for further analysis if necessary. The procedures outlined here allow for a standardized method that can be used and compared between different laboratories and for literature comparison to experimental results.

03 NATURAL GAS↗

Test Methods for Power Tools

Tests of power tools and measurements of the impact energy on the basis of Procedure 05 of the European Power Tools Association (EPTA) and the method in State Standard GOST 55162-2012 are compared by means of the UIPU-4M system (developed by OOO UDARMASh). It is found that the test and measurement methods may be improved, with increase in precision and reproducibility.

42 ENGINEERING↗

SU-E-T-360: End-To-End Dosimetric Testing of a Versa HD Linear Accelerator with the Agility Head Modeled in Pinnacle3

Purpose: The Versa HD incorporates a variety of upgrades, primarily including the Agility head. The distinct dosimetric properties of the head from its predecessors combined with flattening-filter-free (FFF) beams require a new investigation of modeling in planning systems and verification of modeling accuracy. Methods: A model was created in Pinnacle{sup 3} v9.8 with commissioned beam data. Leaf transmission was modeled as <0.5% with maximum leaf speed of 3 cm/s. Photon spectra were tuned for FFF beams, for which profiles were modeled with arbitrary profiles rather than with cones. For verification, a variety of plans with varied parameters were devised, and point dose measurements were compared to calculated values. A phantom of several plastic water and Styrofoam slabs was scanned and imported into Pinnacle{sup 3}. Beams of different field sizes, SSD, wedges, and gantry angles were created. All available photon energies (6 MV, 10 MV, 18 MV, 6 FFF, 10 FFF) as well four clinical electron energies (6, 9, 12, and 15 MeV) were investigated. The plans were verified at a calculation point (8 cm deep for photons, variable for electrons) by measurement with a PTW Semiflex ionization chamber. In addition, IMRT testing was performed with three standard plans (step and shoot IMRT, small and large field VMAT plans). The plans were delivered on the Delta4 IMRT QA phantom (ScandiDos, Uppsala, Sweden). Results: Homogeneous point dose measurement agreed within 2% for all photon and electron beams. Open field photon measurements along the central axis at 100 cm SSD passed within 1%. Gamma passing rates were >99.5% for all plans with a 3%/3mm tolerance criteria. The IMRT QA results for the first 23 patients yielded gamma passing rates of 97.4±2.3%. Conclusion: The end-to-end testing ensured confidence in the ability of Pinnacle{sup 3} to model photon and electron beams with the Agility head.

60 APPLIED LIFE SCIENCES↗

A LASER INTERFERENCE-BASED SURFACE TREATMENT OF AL AND CARBON FIBER POLYMER COMPOSITES FOR ENHANCED BONDING

Due to its increased use in the automotive and aerospace industries, joining of Carbon Fiber-reinforced Polymer matrix Composites (CFPC) to metals demands enhanced surface preparation and control of surface morphology prior to joining. In this study, surfaces of both composite and aluminum were prepared for joining using a new laser based technique, in which the laser interference power profile was created by splitting the beam and guiding those beams to the sample surface by overlapping each other with defined angles to each other. Results were presented for the overlap shear testing of single-lap joints made with Al 5182 and CFPC specimens whose surfaces prepared by (a) surface abrasion and solvent cleaning; and (b) laser-interference structured surfaces by rastering with a 4 mm laser beam at approximately 3.5 W power. CFPC specimens of T700S carbon fiber, Prepreg T70 epoxy, 4 or 5 ply thick, 0/90o plaques were used. Adhesive DP810 was used to bond Al and CFPC. The bondline was 0.25mm and the bond length was consistent among all joints produced. First, the effect of the laser speed on the joint performance was evaluated by laser-interference structure Al and CFPC surfaces with a beam angle of 3o and laser beam speeds of 3, 5, and 10 mm/s. For this sensitivity study, 3 joint specimens were used per each joint type. Based on the results for minimum, maximum, and mean values for the shear lap strength and maximum load for all the 9 joint types, two joint types were selected for further evaluations. Six additional joint specimens were prepared for these two joint types in order to obtain better statistics and the shear test data was presented for the range, mean, and standard deviation. The results for the single-lap shear tests obtained for six joint specimens, indicate that the shear lap strength, maximum load, and displacement at maximum load for those joints made with laser-interference structured surfaces were increased by approximately 14.8%, 16%, and 100%, respectively over those measured for the baseline joints.

Sabau, Adrian S↗

ROLE OF TOXICITY ASSESSMENT AND MONITORING IN MANAGING THE RECOVERY OF A WASTEWATER RECEIVING STREAM

We evaluate the roles of a long-term comprehensive toxicity assessment and monitoring program in management and for ecological recovery of a freshwater receiving stream impacted by industrial discharges and legacy contamination. National Pollution Discharge Elimination Permit (NPDES)-driven whole effluent toxicity (WET) tests using Ceriodaphnia and fathead minnows were conducted for more than twenty years to characterize wastewaters at the US National Nuclear Security Agency s Y-12 National Security Complex in Oak Ridge, Tennessee. Ambient toxicity tests also were conducted to assess water samples from EFPC, the stream receiving the wastewater discharges. The ambient tests were conducted as part of an extensive biological monitoring program that included routine surveys of fish, invertebrate and periphyton communities. WET testing, associated toxicant identification evaluations (TIEs), and ambient toxicity monitoring were instrumental in identifying toxicants and their sources at the Y-12 Complex, guiding modifications to wastewater treatment procedures, and assessing the success of various pollution-abatement actions. Through time, as requirements changed and water quality improved, the toxicity monitoring program became more focused. Ambient testing with Ceriodaphnia and fathead minnow larvae also was supplemented with less-standardized but more-sensitive alternative laboratory and in situ bioassays. The Y-12 Complex biological monitoring experience demonstrates the significant roles effluent and ambient toxicity testing can have in controlling and managing toxic discharges to receiving waters. It also emphasizes the value of supplementing WET and standardized ambient toxicity tests with alternative laboratory and in situ toxicity tests tailored to address specific problems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Effect of Reactor Radiation on the Thermal Conductivity of Graphite-based Dispersion Fuel

The Fukushima Daiichi nuclear accident in 2011 stimulated materials development efforts to improve the current fuel design for Light Water Reactors (LWRs). From fuel element to fuel cladding, new concepts in advanced nuclear fuel development have been proposed, studied, and tested. The new fuel systems are expected to have better resistance to damage, melting, and chemical reaction during accident scenarios. To test the performance and accident tolerance of the advanced fuel, it is highly preferable to simulate off-normal transients in addition to standard in-core fuel performance tests (available at High Flux Isotope Reactor at Oak Ridge National Laboratory and Advanced Test Reactor at Idaho National Laboratory). The Transient Reactor Test Facility (TREAT) is now being prepared to restart its operation, performing transient testing to assist advanced fuel development. TREAT was operated from 1959 to 1994, and was extensively used to generate thousands of reactor transients for different programs. The reactor has not operated since 1994. The original fuel used at TREAT was graphite-based dispersion fuel with highly-enriched uranium (HEU, 93.1% enriched uranium). For nonproliferation purposes, a fuel conversion program, supported by U.S. Department of Energy, National Nuclear Safety Administration (NNSA), Office of Material Management and Minimization (NA-23) Reactor Conversion Program, is underway to develop a replacement core in which the UO{sub 2} contains only low-enriched uranium (LEU). The preliminary LEU core design has shown a much lower carbon/uranium atomic ratio and enrichment than in the HEU core design. To achieve performance similar to the HEU core, the prospective LEU core will contain a much higher density of UO{sub 2} particles. As a result, a higher level of radiation damage, particularly from fission fragments emerging from the UO{sub 2} particles, can be expected dependent on the UO{sub 2} particle size within the fuel. To support LEU fuel design, the present study investigates the effect of reactor radiations on the thermal conductivity of graphite-based dispersion fuel. Both neutron- and fission-radiation induced degradations of the fuel are modeled, and validated based on the available experimental data. In this study, the reactor-radiation induced thermal conductivity degradation of graphite-based dispersion fuel was analyzed. A semi-empirical method to model the relative thermal conductivity with reactor radiations was proposed and validated. The proposed method can be further applied to predict the changes in the thermal conductivity of the prospective LEU TREAT fuel during long-term operation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE 6.2 Lattice Physics Performance Assessment

The US Nuclear Regulatory Commission relies on the lattice physics analysis capabilities of the SCALE code system to perform confirmatory licensing analyses. Either SCALE lattice physics code—TRITON/NEWT or Polaris—can be used to generate cross section data used by the PARCS nodal core simulator for full-core neutronics calculations. This report presents an assessment of the accuracy of SCALE lattice physics codes for preparation of lattice physics data that are used to support simulator codes such as the NRC’s PARCS, for UO 2 -mixed oxide (MOX)/Zr fueled light water reactor (LWR) analyses. Due to the nature of lattice physics calculations, critical reactor experiment benchmarks cannot be modeled in explicit detail in a lattice physics code. However, this limitation does not mean that these measurement data are not usable for lattice physics studies. Therefore, either geometry approximations or axial buckling must be implemented to determine the critical water height. These modeling limitations have led to development of a three-phase assessment strategy. In the first phase, selected critical experiment benchmarks are modeled using the SCALE 3D continuous-energy (CE) Monte Carlo (MC) code KENO, which is the most rigorous neutron transport method available in SCALE, with no approximations in the spatial, angle, or energy treatments. Biases and statistical uncertainties in quantities of interest such as k eff and pin power distributions are determined by comparing CE KENO results to experimental data. This first phase in the accuracy assessment is to demonstrate and establish the use of CE KENO as a reference solution for the second phase. In the second phase, 14 numerical test suites are used to compare SCALE lattice physics calculations with CE KENO as a reference solution. In the third phase, SCALE lattice physics depletion calculations are performed, and the spent fuel isotopic results are compared with available radiochemical assay measurements. Isotopic measurement comparisons provide quantitative assessment of isotopic density distribution predictions with the depletion models in SCALE lattice physics codes. This report documents results for all test suites. The assessment was performed using standard production techniques unless otherwise noted. Both TRITON/NEWT and Polaris exhibited acceptable accuracy for most test cases. For the few test cases in which acceptable accuracy criteria were not met, further code and data development are planned. The computer codes used in this assessment are as follows: SCALE 6.2 rev19189 (pre-release of 6.2.1) was used for CE KENO, TRITON/NEWT and Polaris (PWR only) calculations; SCALE 6.2.2 was used for Polaris calculations to address several updates in support of support boiling water reactor (BWR) lattice geometries. For this work, there is no difference between SCALE 6.2.1 and SCALE 6.2.2 beyond the inclusion of the Polaris BWR analysis capability; The ENDF/B-VII.1 continuous energy and 252 group libraries deployed in SCALE 6.2 were generated with AMPX 6.2 that is distributed with SCALE.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fuel Safety Research Plan for Accident Tolerant Fuels

This document outlines a strategic plan for a safety research program for accident tolerant fuels. Accident tolerant fuels (ATFs) are nuclear fuel materials and designs for existing and future light water reactors. This effort is under the Department of Energy Office of Nuclear Energy’s Nuclear Technology Research and Development Advanced Fuels Campaign. The development of ATF is an industry lead initiative with fuel designs being championed by Westinghouse, Framatome, and General Electric. Industry goals for ATF deployment include implementing the first batch reloads of coated cladding and doped fuel designs into commercial reactors by 2023 and having the first batch reloads of more advanced designs into commercial reactors by 2026. Follow on goals include implementing the first full cores of coated cladding and doped fuel designs into commercial reactors by 2026 and implementing full cores of more advanced designs by 2030. The objectives of the national laboratory research programs within the Advanced Fuels Campaign related to ATF are: 1. Develop and maintain of unique nuclear testing infrastructure, which includes test reactors, hot cell PIE equipment, and unique out of pile separate effects testing facilities. 2. Respond directly to industry requests for support by partnering with the ATF vendors and executing experiments and/or analysis on their behalf. 3. Conduct independent scientific investigations into the performance of the different ATF concepts that are relevant to Industry designs. To achieve these objectives, the safety research program will execute transient irradiation experiments at the TREAT facility at Idaho National Laboratory with the aim of identifying the relevant transient fuel behaviors for each fuel design in order to establish appropriate fuel safety criteria and thresholds. Two test series are described in this plan, (1) an Integral Test Series, and (2) a Focused Effects Test Series. In fulfillment of the first objective for the safety research program, Integral Effects Tests will be developed and demonstrated using standard UO2 Zircaloy fuel designs in both the fresh and previously irradiated case. The Integral Test Series will consist of three campaigns to evaluate transient fuel performance in Reactivity Initiated Accidents, Loss of Coolant Accidents, and in generalized Power Cooling Mismatch scenarios. Development of these test programs also enables the safety research program to fulfill its second objective by making these three test programs available to each industry team. Initially, priority will be given in the integral test series to the coated cladding and doped fuel concepts as their deployment schedule is the most aggressive. To fulfill the third objective of the safety research program, a Focused Effects Test Series is also being developed which will examine specific transient fuel behaviors that are of general interest to all the ATF designs under development. These tests look at transient fuel behavior related to pellet cladding mechanical interaction, coated cladding swelling, rupture, and time at temperature behavior, non oxide fuel melting and mechanical interaction with Silicon Carbide cladding, UO2 and doped UO2 fuel fragmentation and transient fission gas release, and finally fuel coolant interaction. This document provides a general overview of the objectives of the safety research program as well as providing background into how programs like this have been used in the past to develop the criteria necessary for the safe operation of the present fuel designs. An overview of the materials and methods used for safety testing is presented. Finally the Integral and Focused Effects tests series are introduced and described. This document will be maintained as a “living” document with annual updates to reflect evolving requirements and needs.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Search for $p \bar{p} \rightarrow WZ \rightarrow l\nu_l b \bar{b}$ signal with the CDF experiment at Tevatron

The high energy physics has made huge steps forward the comprehension of the inner most nature of our universe and the matter we are composed of. The experimental discoveries, and the theories of the last 50 years that the experimental discoveries had confirmed or inspired, made possible to build a theory of the interactions. Weak interactions have been discovered and unified with the Electromagnetic ones in the Standard Model, which is the most widely experimentally tested and confirmed model of this century. The only prediction which is still unconfirmed is the existence of a particle, the Higgs boson, which provides particles with mass, interacting with them, in a spontaneous symmetry breakdown that doesn't violate the natural gauge symmetry of the Lagrangian of the system. One of the ways in which the Standard Model has been tested during the last 20 years is by accelerating e{sup +}e{sup -} (LEP) or p{bar p} (Tevatron) particles in a circular ring and colliding them inside a detector which is designed to reveal the final reaction products. We now have two operating hadron colliders in the world. The Tevatron at Fermilab laboratory of Chicago, collides protons against anti-protons since 1989 and has reached its maximum energy in the mass center of 1.96 TeV since 2001. It has collected approximately 7 fb{sup -1} of data so far, that allowed important discoveries, as the top quark one, B{sub s} mixing, precision measurements of some of the Standard Model free parameters, e.g. the W mass, and search for New Phenomena. The LHC at CERN in Geneva is a proton proton collider and has started the data acquisition in March 2010, at a center of mass energy of 7 TeV, thus beating the world record of the Tevatron. LHC however has not yet either the integrated luminosity nor the detailed understanding of the detectors to start investigating Higgs or di-boson production. The purpose of this work is to analyse the data of the CDF experiment at Tevatron to search for the associate production of a W{sup {+-}} and Z gauge boson, looking for them in the lepton, neutrino plus jets final state, This process is predicted by the Standard Model but not revealed yet in this particular channel, both for its small cross section ({sigma}{sub WW/WZ} {approx} 16 pb{sup -1}) and for the huge backgrounds we have to deal with. The W{sup +}W{sup -} or W{sup {+-}}Z in l {bar {nu}}{sub l} j j process has been measured for the first time in [4] and represents the starting point of this work. Our aim is to discriminate W{sup {+-}}Z process from W{sup +}W{sup -} one requiring the decay of the Z boson in two b-quarks. The evidence of a peak on the invariant mass distribution will allow a tuning of the invariant mass resolution of b-jets. In addition, one of the main motivations for this quest is the similarity of this exactly predicted process with the W{sup {+-}}H associate production signature, for which it represents a test of the searching tools and techniques, as long as an irreducible background that must be understood before such Higgs search is performed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single x-ray absorptiometry method for the quantitative mammographic measure of fibroglandular tissue volume

Purpose: This study describes the design and characteristics of a highly accurate, precise, and automated single-energy method to quantify percent fibroglandular tissue volume (%FGV) and fibroglandular tissue volume (FGV) using digital screening mammography. Methods: The method uses a breast tissue-equivalent phantom in the unused portion of the mammogram as a reference to estimate breast composition. The phantom is used to calculate breast thickness and composition for each image regardless of x-ray technique or the presence of paddle tilt. The phantom adheres to the top of the mammographic compression paddle and stays in place for both craniocaudal and mediolateral oblique screening views. We describe the automated method to identify the phantom and paddle orientation with a three-dimensional reconstruction least-squares technique. A series of test phantoms, with a breast thickness range of 0.5-8 cm and a %FGV of 0%-100%, were made to test the accuracy and precision of the technique. Results: Using test phantoms, the estimated repeatability standard deviation equaled 2%, with a {+-}2% accuracy for the entire thickness and density ranges. Without correction, paddle tilt was found to create large errors in the measured density values of up to 7%/mm difference from actual breast thickness. This new density measurement is stable over time, with no significant drifts in calibration noted during a four-month period. Comparisons of %FGV to mammographic percent density and left to right breast %FGV were highly correlated (r=0.83 and 0.94, respectively). Conclusions: An automated method for quantifying fibroglandular tissue volume has been developed. It exhibited good accuracy and precision for a broad range of breast thicknesses, paddle tilt angles, and %FGV values. Clinical testing showed high correlation to mammographic density and between left and right breasts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Results from an International Interlaboratory Study on Light- and Elevated Temperature-Induced Degradation (LETID) in Solar Modules

This presentation reports recently submitted results from an international interlaboratory comparison study on light- and elevated temperature-induced degradation (LETID) on crystalline silicon photovoltaic (PV) modules. A large global network of PV module manufacturers and PV testing laboratories collaborated to design a protocol for LETID detection, and screen a large and diverse set of prototype modules for LETID. We summarize the range of observed degradation and provide initial conclusions on the reproducibility of results across labs. In LETID-sensitive modules, both open-circuit voltage (VOC) and short-circuit current (ISC) degrade by a roughly similar magnitude. We observe, as do previous studies, that LETID affects each cell in a module differently. An investigation of the potential mismatch losses caused by nonuniform LETID degradation found that mismatch loss is insignificant compared to the direct LETID-related losses. We summarize the conclusions drawn from the study, provide an update on a forthcoming standard technical specification for LETID testing of PV modules (IEC TS 63342 ED1), and discuss unresolved questions and potential future work on LETID in PV modules.

degradation↗

Compton Scattering Polarimetry for the Determination of the Proton's Weak Charge Through Measurements of the Parity-Violating Asymmetry of 1H(e,e')p

The Standard Model has been a theory with the greatest success in describing the fundamental interactions of particles. As of the writing of this dissertation, the Standard Model has not been shown to make a false prediction. However, the limitations of the Standard Model have long been suspected by its lack of a description of gravity, nor dark matter. Its largest challenge to date, has been the observation of neutrino oscillations, and the implication that they may not be massless, as required by the Standard Model. The growing consensus is that the Standard Model is simply a lower energy effective field theory, and that new physics lies at much higher energies. The Q weak Experiment is testing the Electroweak theory of the Standard Model by making a precise determination of the weak charge of the proton (Q p w ). Any signs of "new physics" will appear as a deviation to the Standard Model prediction. The weak charge is determined via a precise measurement of the parity-violating asymmetry of the electron-proton interaction via elastic scattering of a longitudinally polarized electron beam of an un-polarized proton target. The experiment required that the electron beam polarization be measured to an absolute uncertainty of 1%. At this level the electron beam polarization was projected to contribute the single largest experimental uncertainty to the parity-violating asymmetry measurement. This dissertation will detail the use of Compton scattering to determine the electron beam polarization via the detection of the scattered photon. I will conclude the remainder of the dissertation with an independent analysis of the blinded Q weak .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-117: Verification Method for the Detection Accuracy of Automatic Winston Lutz Test

Purpose: Winston Lutz test (WLT) has been a standard QA procedure performed prior to SRS treatment, to verify the mechanical iso-center setup accuracy upon different Gantry/Couch movements. Several detection algorithms exist,for analyzing the ball-radiation field alignment automatically. However, the accuracy of these algorithms have not been fully addressed. Here, we reveal the possible errors arise from each step in WLT, and verify the software detection accuracy with the Rectilinear Phantom Pointer (RLPP), a tool commonly used for aligning treatment plan coordinate with mechanical iso-center. Methods: WLT was performed with the radio-opaque ball mounted on a MIS and irradiated onto EDR2 films. The films were scanned and processed with an in-house Matlab program for automatic iso-center detection. Tests were also performed to identify the errors arise from setup, film development and scanning process. The radioopaque ball was then mounted onto the RLPP, and offset laterally and longitudinally in 7 known positions ( 0, ±0.2, ±0.5, ±0.8 mm) manually for irradiations. The gantry and couch was set to zero degree for all irradiation. The same scanned images were processed repeatedly to check the repeatability of the software. Results: Miminal discrepancies (mean=0.05mm) were detected with 2 films overlapped and irradiated but developed separately. This reveals the error arise from film processor and scanner alone. Maximum setup errors were found to be around 0.2mm, by analyzing data collected from 10 irradiations over 2 months. For the known shift introduced using the RLPP, the results agree with the manual offset, and fit linearly (R{sup 2}>0.99) when plotted relative to the first ball with zero shift. Conclusion: We systematically reveal the possible errors arise from each step in WLT, and introduce a simple method to verify the detection accuracy of our in-house software using a clinically available tool.

60 APPLIED LIFE SCIENCES↗

SU-D-BRD-03: A Gateway for GPU Computing in Cancer Radiotherapy Research

Purpose: Graphics Processing Unit (GPU) has become increasingly important in radiotherapy. However, it is still difficult for general clinical researchers to access GPU codes developed by other researchers, and for developers to objectively benchmark their codes. Moreover, it is quite often to see repeated efforts spent on developing low-quality GPU codes. The goal of this project is to establish an infrastructure for testing GPU codes, cross comparing them, and facilitating code distributions in radiotherapy community. Methods: We developed a system called Gateway for GPU Computing in Cancer Radiotherapy Research (GCR2). A number of GPU codes developed by our group and other developers can be accessed via a web interface. To use the services, researchers first upload their test data or use the standard data provided by our system. Then they can select the GPU device on which the code will be executed. Our system offers all mainstream GPU hardware for code benchmarking purpose. After the code running is complete, the system automatically summarizes and displays the computing results. We also released a SDK to allow the developers to build their own algorithm implementation and submit their binary codes to the system. The submitted code is then systematically benchmarked using a variety of GPU hardware and representative data provided by our system. The developers can also compare their codes with others and generate benchmarking reports. Results: It is found that the developed system is fully functioning. Through a user-friendly web interface, researchers are able to test various GPU codes. Developers also benefit from this platform by comprehensively benchmarking their codes on various GPU platforms and representative clinical data sets. Conclusion: We have developed an open platform allowing the clinical researchers and developers to access the GPUs and GPU codes. This development will facilitate the utilization of GPU in radiation therapy field.

60 APPLIED LIFE SCIENCES↗

Efficient method for the measurement of lifetime optical damage performance of thin film coatings from laser damage size analysis

Here, a laser damage test method based on damage size analysis (DSA) is described that simplifies the derivation of the lifetime optical damage threshold of film materials critical in the design of devices used in high-repetition-rate, high-power laser systems. The DSA method presented here is solely based on imaging to measure the damage site size produced from exposure to a known Gaussian-shaped beam with a fixed, systematically selected fluence well above the ablation threshold. The method locates the damage boundary produced from repeated exposures, using images with a high contrast, and maps it to the beam profile to extract a lifetime laser damage fluence threshold value. We validate the DSA approach using a few relevant transparent film material systems and by comparing it to the standard S /1 laser damage test method. The DSA method can be more efficient and accelerate materials development and validation necessary to support the design of high-power repetition-rated lasers and optoelectronic devices.

36 MATERIALS SCIENCE↗