Search NASA⌕ Search

SEARCH · Search NASA

Results for “Thick Target”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

First Clinical Investigation of Cone Beam Computed Tomography and Deformable Registration for Adaptive Proton Therapy for Lung Cancer

Purpose: An adaptive proton therapy workflow using cone beam computed tomography (CBCT) is proposed. It consists of an online evaluation of a fast range-corrected dose distribution based on a virtual CT (vCT) scan. This can be followed by more accurate offline dose recalculation on the vCT scan, which can trigger a rescan CT (rCT) for replanning. Methods and Materials: The workflow was tested retrospectively for 20 consecutive lung cancer patients. A diffeomorphic Morphon algorithm was used to generate the lung vCT by deforming the average planning CT onto the CBCT scan. An additional correction step was applied to account for anatomic modifications that cannot be modeled by deformation alone. A set of clinical indicators for replanning were generated according to the water equivalent thickness (WET) and dose statistics and compared with those obtained on the rCT scan. The fast dose approximation consisted of warping the initial planned dose onto the vCT scan according to the changes in WET. The potential under- and over-ranges were assessed as a variation in WET at the target's distal surface. Results: The range-corrected dose from the vCT scan reproduced clinical indicators similar to those of the rCT scan. The workflow performed well under different clinical scenarios, including atelectasis, lung reinflation, and different types of tumor response. Between the vCT and rCT scans, we found a difference in the measured 95% percentile of the over-range distribution of 3.4 ± 2.7 mm. The limitations of the technique consisted of inherent uncertainties in deformable registration and the drawbacks of CBCT imaging. The correction step was adequate when gross errors occurred but could not recover subtle anatomic or density changes in tumors with complex topology. Conclusions: A proton therapy workflow based on CBCT provided clinical indicators similar to those using rCT for patients with lung cancer with considerable anatomic changes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

STEM characterization of solar cells

Photovoltaic (PV) devices consisting of a thin-film CdTe absorber layer on glass support have long been considered one of the leading technologies for reaching the Department of Energy’s 2030 cost target of less than 0.03/kWh. Here, the currently used device architectures include a thin transparent conductive oxide (TCO) on top of the glass superstrate following by very thin (<100 nm) polycrystalline emitter layer, typically CdS or more recently MgZnO (MZO). The CdTe absorber layer is usually up to 4 µm thick and polycrystalline, followed by the back contact (Figure 1). Typical CdTe thin-film layers are formed from rapid deposition techniques, such as close-spaced sublimation (CSS) or high-rate vapor-transport deposition (HRVDT). Both processes result in a polycrystalline CdTe photo-absorbing film, and such devices can be manufactured cheaply and efficiently at large scale. Record cell efficiencies as high as 22.1% have been demonstrated. However, such cell performances are still far from the theoretical limits (~30% for CdTe), and improvements have mostly been due to better light collection, rather than improvements in absorber conversion efficiency. The remaining obstacles to further improving these devices toward their theoretical limits concern improvements in the fill factor (FF) and, more importantly, open-circuit voltage (V oc ), which is still far from its limit. In fact, it is widely accepted that V oc is the limiting factor since it reaches only about 60% of the CdTe bandgap. This is in contrast to GaAs solar cells, which have reached a V oc of 80% of the bandgap. The reasons for this discrepancy have been identified as the low p -type doping concentrations of CdTe due to the formation of compensating defect states, a poor p-n junction, and the need for better backside ohmic contacts. High interfacial defect density at grain boundaries (GBs) and intragrain dislocations is also one of the main concerns because they contribute to the dark current. This is supported by the study of single-crystal-based CdTe solar cells that were able to reach Voc in excess of 1 V.

14 SOLAR ENERGY↗

The Energy Loss of Li and C Ions with MeV Energies in the Polycarbonate and Polypropylene

Stopping power and straggling of Li ions and C ions at mean energy 3.8-5.4 MeV and 5.6-6.9 MeV, respectively, in polycarbonate (PC) and at mean energy 3.7-5.2 MeV and 6.8-8.0 MeV in polypropylene (PP) foils have been measured using ion beams from a Tandetron 4130 MC accelerator. The ions scattered from a thin, primary gold target were registered by a surface barrier detector partially covered with a thin foil of the investigated polymer. The stopping power was determined from the energy difference between the signals from the ions directly backscattered from the Au layer and the ions backscattered and slowed down in the foil. The foil thickness was determined by the weighing procedure. The experimentally determined stopping powers were compared with those calculated with the SRIM 2010 code. The measured stopping powers are in good agreement for Li and C in PC, the differences being within 0.1-1.6% for Li and 0.2-2.1% for C. For Li and C in PP, the stopping powers are lower than the calculated ones, the differences being within 0.5-2.8% for Li and 3.6-6.1% for C. The energy straggling was determined from the width of the RBS signals. The experimentally determined energy straggling was found to fluctuate around the values calculated according to Bohr theory.

36 MATERIALS SCIENCE↗

Density dependence of the symmetry energy from neutron skin thickness in finite nuclei

The density dependence of the symmetry energy, characterized by the parameter L, is studied using information provided by the neutron skin thickness in finite nuclei. An estimate of L is obtained from experimental data of antiprotonic atoms. We also discuss the ability of parity violating electron scatering to obtain information about the neutron skin thickness in {sup 208}Pb.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

SU-F-T-28: Evaluation of BEBIG HDR Co-60 After-Loading System for Skin Cancer Treatment Using Conical Surface Applicator

Purpose: To evaluate the possibility of utilizing the BEBIG HDR 60Co remote after-loading system for malignant skin surface treatment using Monte Carlo (MC) simulation technique. Methods: First TG-43 parameters of BEBIG-Co-60 and Nucletron Ir-192-mHDR-V2 brachytherapy sources were simulated using MCNP6 code to benchmark the sources against the literature. Second a conical tungsten-alloy with 3-cm diameter of Planning-Target-Volume (PTV) at surface for use with a single stepping HDR source is designed. The HDR source is modeled parallel to treatment plane at the center of the conical applicator with a source surface distance (SSD) of 1.5-cm and a removable plastic end-cap with a 1-mm thickness. Third, MC calculated dose distributions from HDR Co-60 for conical surface applicator were compared with the simulated data using HDR Ir-192 source. The initial calculations were made with the same conical surface applicator (standard-applicator) dimensions as the ones used with the Ir-192 system. Fourth, the applicator wall-thickness for the Co-60 system was increased (doubled) to diminish leakage dose to levels received when using the Ir-192 system. With this geometry, percentage depth dose (PDD), and relative 2D-dose profiles in transverse/coronal planes were normalized at 3-mm prescription-depth evaluated along the central axis. Results: PDD for Ir-192 and Co-60 were similar with standard and thick-walled applicator. 2D-relative dose distribution of Co-60, inside the standard-conical-applicator, generated higher penumbra (7.6%). For thick-walled applicator, it created smaller penumbra (<4%) compared to Ir-192 source in the standard-conicalapplicator. Dose leakage outside of thick-walled applicator with Co-60 source was approximately equal (≤3%) with standard applicator using Ir-192 source. Conclusion: Skin cancer treatment with equal quality can be performed with Co-60 source and thick-walled conical applicators instead of Ir-192 with standard applicators. These conical surface applicator must be used with a protective plastic end-cap to eliminate electron contamination and over-dosage of the skin.

60 APPLIED LIFE SCIENCES↗

Designing an impedance-based technique for studying corrosion on cladding materials

In nuclear cladding materials, changes in structure and chemistry over the lifetime of claddings can have a significant impact on fuel and reactor performance. Currently, chemical evolution over the lifetime of the fuel and cladding materials can only be inferred using post-irradiation examination. As an alternative to post-irradiation measurements, electrochemical impedance spectroscopy (EIS) can provide an in-pile measurement of changes in chemistry in oxides and hydrides. The objective of this study is to develop an impedance based sensing technology for measuring spatial- and time-resolved in-pile changes in cladding chemistry in order to understand the mechanisms of hydride formation, hydride dealloying and associated cladding corrosion so that a mitigation strategy and technology can be developed for reactor safe operation. Two prototype impedance-based sensors were designed and assembled using Zr-4 as working electrode and Pt as counter and reference electrode. One sensor is tubular type and the other one is plate-type. These sensors will be tested in static autoclave to investigate the effects of various environmental conditions (including temperature, pressure, and water chemistry) on cladding material corrosion mechanisms. These in-situ EIS sensors would provide corrosion-layer parameters in high-temperature water, such as (1) total layer thickness, (2) the evolution of oxide structures as uniform layer dielectric or sublayer(s), and (3) the possible electrochemistry of the volume corrosion process and the solid/liquid interface, such as the cyclic nature of corrosion of Zr alloys in high-temperature water. This work was focused on electrochemical sensor development, targeting cladding oxides/hydrides under thermodynamic equilibria; characterization of samples using Kelvin probe force microscopy (SKPFM), Raman spectroscopy, and scanning electron microscopy (SEM) with energy-dispersive X-ray spectroscopy (EDS) to provide high-resolution co-localized characterization of zirconium oxide and metal/oxide interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A study to improve the mechanical properties of silicon carbide ribbon fibers

Preliminary deposition studies of SiC ribbon on a carbon ribbon substrate showed that the dominant strength limiting flaws were at the substrate surface. Procedures for making the carbon ribbon substrate from polyimide film were improved, providing lengths up to 450 meters (1,500 ft.) of flat carbon ribbon substrate 1,900 microns (75 mils) wide by 25 microns (1 mil) thick. The flaws on the carbon ribbon were smaller and less frequent than on carbon ribbon used earlier. SiC ribbon made using the improved substrate, including a layer of pyrolytic graphite to reduce further the severity of substrate surface flaws, showed strength levels up to the 2,068 MPa (300 Ksi) target of the program, with average strength levels over 1,700 MPa (250 Ksi) with coefficient of variation as low as 10% for some runs.

Debolt, H. E.↗

The fragmentation of 510 MeV/nucleon iron-56 in polyethylene. I. Fragment fluence spectra

The fragmentation of 510 MeV/nucleon iron ions in several thicknesses of polyethylene has been measured. Non-interacting primary beam particles and fragments have been identified and their LETs calculated by measuring ionization energy loss in a stack of silicon detectors. Fluences, normalized to the incident beam intensity and corrected for detector effects, are presented for each fragment charge and target. Histograms of fluence as a function of LET are also presented. Some implications of these data for measurements of the biological effects of heavy ions are discussed.

NASA Center HQS↗

SIMILARITY PROPERTIES AND SCALING LAWS OF RADIATION HYDRODYNAMIC FLOWS IN LABORATORY ASTROPHYSICS

The spectacular recent development of modern high-energy density laboratory facilities which concentrate more and more energy in millimetric volumes allows the astrophysical community to reproduce and to explore, in millimeter-scale targets and during very short times, astrophysical phenomena where radiation and matter are strongly coupled. The astrophysical relevance of these experiments can be checked from the similarity properties and especially scaling law establishment, which constitutes the keystone of laboratory astrophysics. From the radiating optically thin regime to the so-called optically thick radiative pressure regime, we present in this paper, for the first time, a complete analysis of the main radiating regimes that we encountered in laboratory astrophysics with the same formalism based on Lie group theory. The use of the Lie group method appears to be a systematic method which allows us to construct easily and systematically the scaling laws of a given problem. This powerful tool permits us to unify the recent major advances on scaling laws and to identify new similarity concepts that we discuss in this paper, and suggests important applications for present and future laboratory astrophysics experiments. All these results enable us to demonstrate theoretically that astrophysical phenomena in such radiating regimes can be explored experimentally thanks to powerful facilities. Consequently, the results presented here are a fundamental tool for the high-energy density laboratory astrophysics community in order to quantify the astrophysics relevance and justify laser experiments. Moreover, relying on Lie group theory, this paper constitutes the starting point of any analysis of the self-similar dynamics of radiating fluids.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP4-06: Feasibility of External Beam Treatment Field Verification Using Cherenkov Imaging

Purpose: Cherenkov light emission has been shown to correlate with ionizing radiation (IR) dose delivery in solid tissue. In order to properly correlate Cherenkov light images with real time dose delivery in a patient, we must account for geometric and intensity distortions arising from observation angle, as well as the effect of monitor units (MU) and field size on Cherenkov light emission. To test the feasibility of treatment field verification, we first focused on Cherenkov light emission efficiency based on MU and known field size (FS). Methods: Cherenkov light emission was captured using a PI-MAX4 intensified charge coupled device(ICCD) system (Princeton Instruments), positioned at a fixed angle of 40° relative to the beam central axis. A Varian TrueBeam linear accelerator (linac) was operated at 6MV and 600MU/min to deliver an Anterior-Posterior beam to a 5cm thick block phantom positioned at 100cm Source-to-Surface-Distance(SSD). FS of 10×10, 5×5, and 2×2cm{sup 2} were used. Before beam delivery projected light field images were acquired, ensuring that geometric distortions were consistent when measuring Cherenkov field discrepancies. Cherenkov image acquisition was triggered by linac target current. 500 frames were acquired for each FS. Composite images were created through summation of frames and background subtraction. MU per image was calculated based on linac pulse delay of 2.8ms. Cherenkov and projected light FS were evaluated using ImageJ software. Results: Mean Cherenkov FS discrepancies compared to light field were <0.5cm for 5.6, 2.8, and 8.6 MU for 10×10, 5×5, and 2×2cm{sup 2} FS, respectably. Discrepancies were reduced with increasing field size and MU. We predict a minimum of 100 frames is needed for reliable confirmation of delivered FS. Conclusion: Current discrepancies in Cherenkov field sizes are within a usable range to confirm treatment delivery in standard and respiratory gated clinical scenarios at MU levels appropriate to standard MLC position segments.

60 APPLIED LIFE SCIENCES↗

Characterization and Accelerated Life Testing of a New Solid Oxide Electrolysis Cell

The project aims to develop mechanistic degradation models that realistically predict long-term Solid Oxide Electrolysis Cell (SOEC) durability, using input data from accelerated electrochemical life testing combined with quantitative microstructural and microchemical evaluation. A promising SOEC type will be further developed. The understanding achieved by combining experimental results and theory will be used to guide improvements in long-term SOEC durability, and validate that this technology can reach DOE H 2 production cost and durability targets. Planned outcomes include: (1) new experimental accelerated testing data on SOEC degradation at the oxygen electrode, fuel electrode, and electrolyte; (2) predictive theory of degradation developed based on the accelerated test data; (3) new electrode materials and processing methods that minimize degradation rate; (4) determination of the impact of SOEC electrolyte thickness and electrode composition/microstructure on performance and degradation; (5) determination of the operating conditions where degradation is minimized; and (6) validation of degradation models for extrapolating accelerated test data to predict long-term durability.

08 HYDROGEN↗

Formation of the layered deposits in the Valles Marineris, Mars

Thick sequences of layered deposits are found in the Valles Marineris, which exhibit fine, nearly horizontal layering, and are present as isolated plateaus of what were once more extensive deposits. It was argued that the morphology of the deposits is most consistent with origin in standing bodies of water. The conditions necessary for the existence of ice-covered Martian paleolakes are examined in detail and mechanisms for sediment deposition in them are considered. It was concluded that there are several geologically feasible mechanisms that could have led to the formation of thick deposits in ice-covered paleolakes in the Valles Marineris. Present data are insufficient to choose conclusively among the various possibilities. Several types of data from the Mars Observer mission will be useful in further characterizing the deposits and clarifying the process of their origin. The deposits should be considered important targets for a future Mars sample return mission.

Nedell, Susan S.↗

Fabrication of Nanopipette Arrays for Biosensing

Method for providing a nanopipette array for biosensing applications. A thin substrate of anodizable metal ("AN-metal," such as Al, Mg, Zn, Ti, Ta and/or Nb) is anodized at temperature T=20-200.degree. C., chemical bath pH=4-6 and electrical potential 1-300 Volts, to produce an array of anodized nanopipette channels, having diameters 10-50 nm, with oxidized channel surfaces of thickness 5-20 nm. A portion of exposed non-oxidized AN-metal between adjacent nanopipette channels, of length 1-5 .mu.m, is etched away, exposing inner and outer surfaces of a nanopipette channel. A probe molecule, is deposited on one or both surfaces to provide biosensing capability for K(.gtoreq.1) target molecules. Target molecule presence, in an above-threshold concentration, in a fluid passed through or adjacent to a nanopipette channel, produces characteristic detection signals associated with the probe molecule site.

Meyyappan, Meyya↗

Reduced discretization error in HZETRN

The deterministic particle transport code HZETRN is an efficient analysis tool for studying the effects of space radiation on humans, electronics, and shielding materials. In a previous work, numerical methods in the code were reviewed, and new methods were developed that further improved efficiency and reduced overall discretization error. It was also shown that the remaining discretization error could be attributed to low energy light ions (A < 4) with residual ranges smaller than the physical step-size taken by the code. Accurately resolving the spectrum of low energy light particles is important in assessing risk associated with astronaut radiation exposure. In this work, modifications to the light particle transport formalism are presented that accurately resolve the spectrum of low energy light ion target fragments. The modified formalism is shown to significantly reduce overall discretization error and allows a physical approximation to be removed. For typical step-sizes and energy grids used in HZETRN, discretization errors for the revised light particle transport algorithms are shown to be less than 4% for aluminum and water shielding thicknesses as large as 100 g/cm{sup 2} exposed to both solar particle event and galactic cosmic ray environments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Backscatter Correction Algorithm for TBI Treatment Conditions

The accuracy requirements in target dose delivery is, according to ICRU, ±5%. This is so not only in standard radiotherapy but also in total body irradiation (TBI). Physical dosimetry plays an important role in achieving this recommended level. The semi-infinite phantoms, customarily used for dosimetry purposes, give scatter conditions different to those of the finite thickness of the patient. So dose calculated in patient’s points close to beam exit surface may be overestimated. It is then necessary to quantify the backscatter factor in order to decrease the uncertainty in this dose calculation. The backward scatter has been well studied at standard distances. The present work intends to evaluate the backscatter phenomenon under our particular TBI treatment conditions. As a consequence of this study, a semi-empirical expression has been derived to calculate (within 0.3% uncertainty) the backscatter factor. This factor depends lineally on the depth and exponentially on the underlying tissue. Differences found in the qualitative behavior with respect to standard distances are due to scatter in the bunker wall close to the measurement point.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ohmic contact formation on n-type Ge by direct deposition of TiN

We succeeded in Ohmic contact formation on an n-Ge substrate by direct sputter deposition from a TiN target and subsequent postmetallization annealing (PMA) at 350 deg. C. The Schottky barrier heights of the TiN/n-Ge and TiN/p-Ge contacts were 0.18 eV and 0.50 eV, respectively, and were maintained up to a PMA temperature of 550 deg. C. These electrical characteristics are likely to be associated with an approximately 1-nm-thick interlayer formed at a TiN/Ge interface, which leads to the alleviation of the Fermi level pinning. We demonstrated the validity of the TiN/n-Ge contact using an n{sup +}/p junction, which showed an excellent ideal factor of n=1.01.

36 MATERIALS SCIENCE↗

Ultrashort megaelectronvolt positron beam generation based on laser-accelerated electrons

Experimental generation of ultrashort MeV positron beams with high intensity and high density using a compact laser-driven setup is reported. A high-density gas jet is employed experimentally to generate MeV electrons with high charge; thus, a charge-neutralized MeV positron beam with high density is obtained during laser-accelerated electrons irradiating high-Z solid targets. It is a novel electron–positron source for the study of laboratory astrophysics. Meanwhile, the MeV positron beam is pulsed with an ultrashort duration of tens of femtoseconds and has a high peak intensity of 7.8 × 10{sup 21} s{sup −1}, thus allows specific studies of fast kinetics in millimeter-thick materials with a high time resolution and exhibits potential for applications in positron annihilation spectroscopy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Epitaxial growth and thermodynamic stability of SrIrO{sub 3}/SrTiO{sub 3} heterostructures

Obtaining high-quality thin films of 5d transition metal oxides is essential to explore the exotic semimetallic and topological phases predicted to arise from the combination of strong electron correlations and spin-orbit coupling. Here, we show that the transport properties of SrIrO{sub 3} thin films, grown by pulsed laser deposition, can be optimized by considering the effect of laser-induced modification of the SrIrO{sub 3} target surface. We further demonstrate that bare SrIrO{sub 3} thin films are subject to degradation in air and are highly sensitive to lithographic processing. A crystalline SrTiO{sub 3} cap layer deposited in-situ is effective in preserving the film quality, allowing us to measure metallic transport behavior in films with thicknesses down to 4 unit cells. In addition, the SrTiO{sub 3} encapsulation enables the fabrication of devices such as Hall bars without altering the film properties, allowing precise (magneto)transport measurements on micro- and nanoscale devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗