Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALLS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Nozzle and cavity wall cooling limitations on specific impulse of a gas-core nuclear rocket.

Experimental and theoretical study of the performance of a gas-core nuclear rocket, showing that in a uranium plasma nuclear rocket with an 8-ft cavity diameter the cavity wall can be cooled up to a power level of 7400 MW when the rocket operates at a pressure of 1000 atm and the propellant mass flow rate is 10 lbm/sec. A maximum cavity specific impulse of 5800 sec was obtained under such operating conditions. The fact that the wall heat flux was much lower for reactor powers below this level is linked to the presence of a relatively cool, opaque insulating layer of seeded propellant between the hot plasma and the solid wall. The additional coolant required for nozzle protection reduced the maximum cavity specific impulse to 5200 sec.

Kascak, A. F.↗

Air film cooling in a nonadiabatic wall conical nozzle.

Experimental data for an air-film cooled conical nozzle operating with a heated-air main stream and a water-cooled wall confirm the validity of Lieu's (1964) method for correlating film cooling data in the accelerated flow of a nonadiabatic-wall nozzle. The film cooling effectiveness modified for nonadiabatic walls by Lieu can be used to correlate film cooling under the condition that the main-stream to coolant velocity ratio at the slot is about 1. Such a ratio provides the optimum cooling effectiveness.

Boldman, D. R.↗

Computation of wall effects in ventilated transonic wind tunnels.

A method for computing interference effects due to ventilated wind-tunnel walls on lifting transonic airfoils is presented. Differences between the present method based on nonlinear transonic theory and the classical correction formulae from linear subsonic theory are discussed. Computed results are presented for an NACA 0012 in solid and perforated wall tunnels. The solid wall calculations are compared with data.

Murman, E. M.↗

Control of exit velocity profile of an asymmetric annular diffuser using wall suction

An asymmetric annular diffuser equipped with wall bleed (suction) capability was tested for controllability of exit velocity profile. The diffuser area ratio was 3.2, and the length to inlet height ratio was 1.6. Results show that the diffuser radial exit velocity profile could be controlled from a hub peaked to a tip peaked form by selective use of bleed on the outer wall or on both diffuser walls. Based on these results, application of the diffuser bleed technique to gas turbine combustors may be possible. Diffuser bleed could be used to tailor the airflow distribution for optimizing combustor performance at a variety of operating conditions.

Juhasz, A. J.↗

Design and experimental performance of short curved wall diffusers with axial symmetry utilizing slot suction

The feasibility of designing short curved wall axially symmetrical subsonic diffusers utilizing suction through slots in the diffuser walls to prevent flow separation was investigated. A potential flow analysis was made, and a digital computer program was written for determining the diffuser wall contour for prescribed boundary conditions. The flow field included branch flow so that the suction slot geometry could be a part of the diffuser design. One bell shaped diffuser and three annular diffusers with area ratios of either 2.5:1 or 3:1 were designed, fabricated, and tested. Minimum suction requirements of metastable operation ranged from 6.3 percent to 12 percent when operating with inlet air velocities in the 1000 to 250 ft/sec (30 to 76 m/sec) range. For stable operation suction rates from 10 percent to 22 percent were required. In all cases the diffuser effectiveness was above 95 percent based on the conventional definition, and from 81 percent to 94 percent when the suction loss was accounted for. The exit velocity profiles were virtually flat with no more than + or - 9% variation over 95 percent of the exit area when operated with sufficient suction to prevent flow separation.

Yang, T.↗

Net radiation method for enclosure systems involving partially transparent walls

The net radiation method is developed for analyzing radiation heat transfer in enclosure systems involving partially transparent walls. One such system is an enclosure with windows in it. The conventional net radiation method was developed for enclosures having opaque walls. If a partially transparent wall is present, it will permit radiation to enter and leave the enclosure. The net radiation equations are developed here for gray and semigray enclosures with one or more windows. Another system of interest, such as in a flat plate solar collector, consists of a series of parallel transparent layers. The transmission characteristics of such window systems are obtained by the net radiation method, and the technique appears to be more convenient than the ray tracing method which has been used in the past. Relations are developed for windows consisting of any number of parallel layers having differing absorption coefficients and differing surface reflectivities, and for systems composed of parallel transmitting layers and opaque plates.

Siegel, R.↗

Experimental investigation of a wall stablized arc with comparisons to theoretical predictions

A wall-stabilized, constricted-arc heater was investigated by extensive measurements of pressure, voltage, and wall heat flux at different axial locations along the constrictor. Radial temperature profiles were measured at one axial location by the radiance of a single line method and also by the continuum radiance at a wavelength of 4955 A. The arc heater with an inside diameter of 2.37 cm and a constrictor length of 42 cm was operated with nitrogen flow rate from about 2 to 10 g/sec, and are currents from 400 to 1200 amperes. Based on a literature search, two different digital computer programs were selected which were used to predict the pertinent parameters by numerical solutions to the governing differential equations. The program selections were based on completeness and availability. In general the predictions were adequate when laminar flow was assumed, and the greatest difficulty was encountered in the predictions of wall heat flux. The results of the measurements are shown in graphical form, along with the theoretical predictions from both computer programs.

Wells, W. L.↗

Experimental study of shock-wave reflection from a thermally accommodating wall.

Shock-tube experiments have been conducted to study the nonequilibrium gas-surface interaction which occurs when a thick shock wave in argon reflects from a coplanar, heat-conducting wall. Fast-response instrumentation was used to monitor variations in temperature and normal stress on the surface of the shock-tube end wall during and immediately following reflection of the incident shock wave. The laboratory observations are compared with computer predictions obtained by Deiwert using the direct-simulation Monte Carlo method, and excellent agreement is obtained when a suitable average thermal accommodation coefficient is chosen for the wall surface.

Hanson, R. K.↗

Reflection of a shock wave from a thermally accommodating wall - Molecular simulation.

Reflection of a plane shock wave from a wall has been simulated on a microscopic scale using a direct simulation Monte Carlo technique of the type developed by Bird. A monatomic gas model representing argon was used to describe the fluid medium and a simple one-parameter accommodation coefficient model was used to describe the gas-surface interaction. The influence of surface accommodation was studied parametrically by varying the accommodation coefficient from zero to one. Results are presented showing the temporal variations of flow field density, and mass, momentum, and energy fluxes to the wall during the shock wave reflection process. The energy flux was used to determine the wall temperature history. Comparisons with experiment are found to be satisfactory where data are available.

Deiwert, G. S.↗

Discrete wall jets in quiescent air

An experimental investigation was made of turbulent jet flows resulting from small, round nozzles discharging parallel to a smooth, flat wall in quiescent air. Nozzle axes were located 3.0 nozzle diameters above the wall surface. The case of a single nozzle and the case of a spanwise array of equally spaced nozzles were investigated. Several forms of approximate velocity profile similarity were noted, and the flow from the array of nozzles was seen to approach the form of a two-dimensional wall jet.

Mclean, J. D.↗

Evaluation of analytical procedures for prediction of turbulent boundary layers on a porous wall

An analytical study has been made to determine how well current boundary layer prediction techniques work when there is mass transfer normal to the wall. The data that were considered in this investigation were for two-dimensional, incompressible, turbulent boundary layers with suction and blowing. Some of the bleed data were taken in an adverse pressure gradient. An integral prediction method was used three different porous wall skin friction relations, in addition to a solid-surface relation for the suction cases. A numerical prediction method was also used. Comparisons were made between theoretical and experimental skin friction coefficients, displacement and momentum thicknesses, and velocity profiles. The integral method with one of the porous wall skin friction laws gave very good agreement with data for most of the cases considered. The use of the solid-surface skin friction law caused the integral to overpredict the effectiveness of the bleed. The numerical techniques also worked well for most of the cases.

Towne, C. E.↗

Refractive index of plant cell walls

Air was replaced with media of higher refractive indices by vacuum infiltration in leaves of cucumber, blackeye pea, tomato, and string bean plants, and reflectance of noninfiltrated and infiltrated leaves was spectrophotometrically measured. Infiltrated leaves reflected less light than noninfiltrated leaves over the 500-2500-nm wavelength interval because cell wall-air interfaces were partly eliminated. Minimal reflectance should occur when the average refractive index of plant cell walls was matched by the infiltrating fluid. Although refractive indices that resulted in minimal reflectance differed among the four plant genera, an average value of 1.425 approximates the refractive index of plant cell walls for the four plant genera.

Gausman, H. W.↗

The design and performance of axially symmetrical contoured wall diffusers employing suction boundary layer control

This paper presents a procedure for the design and the performance prediction of axially symmetrical contoured wall diffusers employing suction boundary layer control. An inverse problem approach was used in the potential flow design of the diffuser wall contours. The experimentally observed flow characteristics and the stability of flows within the diffuser are also described. Guidelines for the design of low suction (less than 10 percent of the inlet flow) and thus high effectiveness contoured wall diffusers are also provided based on the results of the experimental program.

Nelson, C. D., Jr.↗

Wall pressure spectra calculations for equilibrium boundary layers

Calculation of the flow direction wave-number spectrum of pressure fluctuations on the wall under a turbulent boundary layer. Particular attention is paid to finding the spectral density of the wall pressure fluctuations as a function of the streamwise wave number. For this purpose a five-dimensional integration is employed in which the equilibrium boundary layers are assumed to have velocity profiles given by the law of the wall plus Cole's wake function.

Panton, R. L.↗

Sound waves in two-dimensional ducts with sinusoidal walls

The method of multiple scales is used to analyze the wave propagation in two-dimensional hard-walled ducts with sinusoidal walls. For traveling waves, resonance occurs whenever the wall wavenumber is equal to the difference of the wavenumbers of any two duct acoustic modes. The results show that neither of these resonating modes could occur without strongly generating the other.

Nayfeh, A. H.↗

Method of fabricating an object with a thin wall having a precisely shaped slit

A method is described for making a structure with a cavity and a thin wall with a precisely shaped slit. An object with a cavity having two openings, one of which is to be closed by a thin wall with a slit, is placed on the surface of a fixture. The fixture surface has a slot conforming to the size and shape of the slit to be formed in the thin wall.

Christopher, P. A.↗

Wall mounted heat exchanger characterization

Analytical models are presented for describing the heat and mass transfer and the energy distribution in the contents of a cryogenic propellant tank, under varying gravity levels. These models are used to analytically evaluate the effectiveness of a wall heat exchanger as a means of controlling the pressure in the tank during flight and during fill operations. Pressure and temperature histories are presented for tanks varying in size from 4 to 22.5 feet in diameter and gravity levels from 0-1. Results from the subscale test program, utilizing both non-cryogenic and cryogenic fluid, designed to evaluate a tank wall heat exchanger are described and compared with the analytical models. Both the model and test results indicate that a passive tank wall heat exchanger can effectively control tank pressure. However, the weight of such a system is considerably higher than that of an active mixer system.

Bullard, B. R.↗

Two-dimensional radiative equilibrium of a gray medium in a plane layer bounded by gray nonisothermal walls

Radiative equilibrium temperature and surface heat flux distributions are calculated for an absorbing-emitting gray medium in an infinite plane layer bounded by gray diffuse walls with arbitrary temperature distributions. Superposition is used to obtain the solution for the differential approximation, which yields good accuracy for the optically thick medium. To also obtain accurate results for optically thin and intermediate regimes, the differential approximation is subsequently improved by a number of geometrical parameters, which are derived from the exact expression for the intensity. As an example, the case of constant temperature at the upper wall and a temperature step at the lower wall without heat generation in the medium is presented. Comparison with other available results shows excellent agreement.

Modest, M. F.↗