Search NASA⌕ Search

SEARCH · Search NASA

Results for “analysis programs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Development of Automated Software Program for the Analysis of Alzheimer's Disease Scans: Evaluation of PET imaging with PBR-111 in HV and AD subjects

Study goal: A Phase 1 evaluation of the kinetics, clearance and cerebral distribution of one novel peripheral benzodiazepine receptors(PBR)positron emission tomography (PET) imaging agent, 18F-PBR-111 following intravenous administration in healthy volunteers and Alzheimer's disease (AD) patients. Short title: Evaluation of PET imaging with PBR-111 in HV and AD subjects Proof of Mechanism. Primary Objective: To evaluate the cerebral distribution of PBR-111 positron emission tomography (PET) for detection/exclusion of microglial activation in patients with Alzheimer's disease subjects compared to healthy volunteers. Secondary objectives: - To assess the dynamic uptake and washout of [18F]PBR-111, a potential imaging bio-marker for inflammatory changes in brain, using positron emission tomography in subjects with Alzheimer's disease (AD) and healthy volunteers (HV). - To perform blood metabolite characterization of [18F]PBR-111 in subjects with AD and HV to determine the nature of metabolites in assessment of [18F]-PBR-111 as a PET brain imaging agent. Name of radioactive drug substance: PBR-111 Dose(s): The applied PBR-111 radioactive dose will be up to 5.0 mCi, diluted in a maximum of 10 ml of saline. The radioligand will be administered as a slow intravenous bolus injection (i.e., 6 sec/ml) into a large vein (e.g., antecubital vein). Route of administration: Intravenous injection Duration of treatment: Single administration of a diagnostic agent Indication: PBR-111 positron emission tomography (PET) imaging has the potential to detect microglial activation. In the presence of PBR-111 uptake (representative of microglial activation), inflammation in the brain can be detected. Diagnosis and main criteria for inclusion: Study participants will be HVs and patients diagnosed with probable AD. HVs must be 18 years of age (at least four subjects 50 years of age) and have no evidence of cognitive impairment or other neurologic disease by medical history. The lack of cognitive impairment will also be based on a Clinical Dementia Rating (CDR) of 0. Patients with probable AD must be 50 years of age and must fulfill the National Institute of Neurological and Communicative Disorders and Stroke, Alzheimer's Disease and Related Disorders Association [NINCDS-ADRDA] criteria for probable AD. The CDR score must be 1.0 and 2.0 and have a modified Hachinski of 4. All HVs and all patients with probable AD must be able to comply with all study procedures. Study design: This is a Phase 1, open-label, single-center, non-randomized single dose study to assess the kinetics, clearance and cerebral distribution of PBR-111 PET imaging in detecting microglial activation in the brain in patients with probable AD compared to HVs. All aspects related to image acquisition, processing, and visual as well as quantitative evaluation will be developed, optimized, and validated (where required). Each subject will be required to visit the study center during the screening phase and on the PBR-111 PET imaging day (baseline). A telephone follow-up visit will be performed 7 days (± 3 days) after PBR-111 PET administration. At the screening visit, each subject (or caregiver in the case of AD subjects) will be asked to provide written informed consent or assent. During the screening phase (maximum duration of 60 days) subject medical, neurological, and surgical history, clinical assessments, and a neuro-psychiatric evaluation will be performed on all eligible subjects. Subjects will be allowed to leave the center after all evaluations have been completed. During this period an MRI of the brain will be performed during the screening period. If an MRI of the brain has been performed within six months of the imaging visit using the methods described in the protocol, and there has been no medically significant events in the interim, the previous MRI may be used. During the PBR-111 PET imaging day, all subjects will receive a single intravenous injection of PBR-111 and scanning will be performed over a 3.5 hour period. Each subject will have a telephone follow-up 7 days (± 3 days) thereafter to assess for adverse events. Methodology: - Assessments to provide clinical characterization of the AD subjects will be performed. - After administration of PBR-111, images will be generated with state-of-the-art PET imaging. Images will be assessed quantitatively for the presence of microglial activation by a nuclear physician blinded to clinical data. - Total radioactivity and estimation of the fraction of radioactivity associated to the un-metabolized tracer will be determined. In addition, the metabolite patterns of PBR-111 are determined in venous plasma and arterial samples based on high-performance liquid chromatography (HPLC) analyses. - Arterial sampling will be acquired in the initial two AD and two HV subjects and modeling will be assessed to determine if additional arterial sampling is necessary.

97 MATHEMATICS AND COMPUTING↗

SSL Pricing and Efficacy Trend Analysis for Utility Program Planning

An LED lamp or luminaire can generally be found that matches or exceeds the efficacy of benchmark technologies in a given product category, and LED products continue to expand into ever-higher lumen output niches. However, the price premium for LED continues to pose a barrier to adoption in many applications, in spite of expected savings from reduced energy use and maintenance. Other factors—such as dimmability and quality of light—can also present challenges. The appropriate type, timing, and magnitude of energy efficiency activities will vary from organization to organization based on local variables and the method of evaluation. A number of factors merit consideration when prioritizing activities for development. Category-specific projections for pricing and efficacy are provided herein to assist in efficiency program planning efforts.

COST↗

A Unified Data-Driven Approach for Programming In Situ Analysis and Visualization: An Interim Report of Sandia Sub-Team Contributions

As we look ahead to next generation high performance computing platforms, the placement and movement of data is becoming the key-limiting factor on both performance and energy efficiency. Furthermore, the increased quantities of data the systems are capable of generating, in conjunction with the insufficient rate of improvements in the supporting I/0 infrastructure, is forcing applications away from the off-line post-processing of data towards techniques based on in ,situ analysis and visualization. Together, these challenges are shaping how we will both design and develop effective, performant and energy-efficient software. In particular, the challenges highlight the need for data and data-centric operations to be fundamental in the reasoning about, and optimization of, scientific workflows on extreme-scale architectures.

97 MATHEMATICS AND COMPUTING↗

Thermal analysis system /TAS-1/ program

Digital computer program develops temperature control system which maintains various subsystems within proper temperature limits. Coding is simple and input rules are easy to use and remember. Output format is easy to understand and to analyze for error diagnosis.

Hultberg, J. A.↗

Modular space station Phase B extension

The modular space station concept and preliminary design are outlined. The premission operations, reference programs, baseline program costs, sortie analysis, and program options are covered.

Cole, E. G.↗

Program of solar wind data analysis utilizing data from Pioneer 6, Mariner 5 and explorer 35

A combined data analysis and theoretical program aimed at interpreting and utilizing solar wind data obtained from Pioneer 6, Mariner 5, and Explorer 35 has been completed. A theoretical model of the radial dependence of large scale solar wind inhomogeneities was developed and used to map solar wind variations measured by Explorer 35 to various heliocentric distances and to the orbits of Mercury, Venus, and Mars. The model was also used to determine power spectra velocity, density and temperature variations of 20 R sub s from spectra obtained from the Mariner 5 data at an average heliocentric distance of 180 R sub s. Five stream-stream interaction events in the Pioneer 6 data were analyzed which confirmed the picture of a spiral compression ridge interfacing the two streams and the associated east-west deflections of the solar wind flow. Magnetopause crossings observed in Explorer 35 plasma data were used to develop statics on boundary motions at lunar distance. A study of the geomagnetic disturbance field asymmetry was performed and a model of disturbance field from a partial ring current was developed.

Siscoe, G. L.↗

Operations analysis (study 2.1). Program SEPSIM (solar electric propulsion stage simulation)

Program SEPSIM is a FORTRAN program which performs deployment, servicing, and retrieval missions to synchronous equatorial orbit using a space tug with a continuous low thrust upper stage known as a solar electric propulsion stage (SEPS). The SEPS ferries payloads back and forth between an intermediate orbit and synchronous orbit, and performs the necessary servicing maneuvers in synchronous orbit. The tug carries payloads between the orbiter and the intermediate orbit, deploys fully fueled SEPS vehicles, and retrieves exhausted SEPS vehicles when, and if, required. The program is presently contained in subroutine form in the Logistical On-orbit VEhicle Servicing (LOVES) Program, but can also be run independently with the addition of a simple driver program.

Lang, T. J.↗

JPL transient radiation analysis by computer program (JTRAC)

Digital computer program, JTRAC, simulates time response of electronic circuit to arbitrary forcing functions which may include electrical and/or radiation stimuli. Program is designed to solve linear and nonlinear simultaneous equations which characterize mathematical models used to predict circuit response for electrical and/or radiation input.

Weinstein, S.↗