At least 1,711 records · Page 95

Ultramicro to mesopore frameworks for selective separation and storage of noble gases

Methods and materials for the selective capture and storage of preselected materials from gas streams using metal organic framework (MOF) materials are described. In various embodiments preselected target material gases could include noble gasses such as Kr, Xe, Rn, Arultramicro to mesopore frameworks for selective separation and storage of noble gases, other gasses such as I2 or other particular isotopes either naturally occurring or man-made, or another preselected gas capture material such as a target material for legal, regulatory or treaty compliance, or a preselected material from a particular process such as a cleaning or etching agent from semiconducting or microelectronic manufacture, or a portion of an anesthetic gas such as nitrous oxide, isoflurane, sevoflurane or a fluorinated ethers.

Thallapally, Praveen K.↗

In-Situ Characterization of Underwater Radioactive Sludge

A fundamental requirement underpinning safe clean-up technologies for legacy spent nuclear fuel (SNF) ponds, pools and wet silos is the ability to characterize the radioactive waste form prior to retrieval. The corrosion products resulting from the long term underwater storage of spent nuclear fuel, reactor components and reprocessing debris present a major hazard to facility decontamination and decommissioning in terms of their radioactive content and physical / chemical reactivity. The ability to perform in-situ underwater non-destructive characterization of sludge and debris in a safe and cost-effective manner offers significant benefits over traditional destructive sampling methods. Several techniques are available for underwater measurements including (i) Gross gamma counting, (ii) Low-, Medium- and High- Resolution Gamma Spectroscopy, (iii) Passive neutron counting and (iv) Active Neutron Interrogation. The optimum technique depends on (i) the radioactive inventory (ii) mechanical access restrictions for deployment of the detection equipment, interrogation sources etc. (iii) the integrity of plant records and (iv) the extent to which Acceptable Knowledge which may be used for 'fingerprinting' the radioactive contents to a marker nuclide. Prior deployments of underwater SNF characterization equipment around the world have been reviewed with respect to recent developments in gamma and neutron detection technologies, digital electronics advancements, data transfer techniques, remote operation capabilities and improved field ruggedization. Modeling and experimental work has been performed to determine the capabilities, performance envelope and operational limitations of the future generation of non-destructive underwater sludge characterization techniques. Recommendations are given on the optimal design of systems and procedures to provide an acceptable level of confidence in the characterization of residual sludge content of legacy wet storage facilities such that retrieval and repackaging of SNF sludges may proceed safely and efficiently with support of the regulators and the public. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Researching Plant Growth in Amended Martian Regolith Simulant, Photosynthetic Rates of Plants, Seed Surface Decontamination by Plasma Methods, New Crop Development, and Porous Concrete Media

Plant growth research for food production at Kennedy Space Center looks at how future residents of Mars and the Moon will enjoy the sight, smell, taste, and nutrition of plants. Overall, the goal is to provide a sustainable source of healthy food, on long-duration space flights, so astronauts can get the nutrition they need and produce food. The sustainable production of food will aid in the efforts of closed life support. Plants have a vital application for bio regenerative life support as demands for food and oxygen can be provided through photosynthesis, while the carbon dioxide from human respiration is removed. Transpiration is also used in life support processes as waste water that can be recycled through plant systems with the resultant humidity then condensed as clean water. Selected crops will provide the nutrient requirements needed for long duration space flight. Currently, projects in food production are investigating how plants grow in Martian regolith simulant, new crops testing with tomato and pepper cultivars, acquiring real-time photosynthetic data on crops, assessing plant growth in porous concrete media, and the use of plasma for surface decontamination of seeds.

food production↗

Computational Math Problems for a Clean Energy Future

Cutting edge computational mathematics are ubiquitous in renewable energy research. Problems in resilient and reliable electric grid operations, infrastructure planning, wind farm yaw control, and more demand sophisticated and scalable computational tools that enable the transition of renewable energy technologies from proof of concept to deployment into our energy system. The mission of the Computational Science Center at NREL is to lead the lab's efforts to solve energy challenges using high-performance computing (HPC), computational science, applied mathematics, scientific data management, visualization, and informatics. In this poster, we provide a short overview of three areas of computational mathematics research at NREL: wind power scenario generation for stochastic grid operations and infrastructure planning, improved rational function approximations for electromagnetic transients codes, and wind farm yaw control using a combination of the Alternating Direction Method of Multipliers (ADMM) and reinforcement learning (RL). Increasing penetrations of renewable energy into power grids motivate the investigation of new approaches to characterizing uncertainty for five-minute economic dispatch problems. Similarly, as the penetration of distributed energy resources on power grids increases, it becomes important to revisit our methods of modelling transient phenomena, i.e. electromagnetic transients programs. Finally, the combination of ADMM and RL for wind farm yaw control presented here can potentially increase the efficiency of the deployed distributed controllers by orders of magnitude.

ADMM↗

Counterpart identification and classification for eRASS1 and characterisation of the active galactic nuclei content

Context. Accurately accounting for the Active Galactic Nucleus (AGN) phase in galaxy evolution requires a large, clean AGN sample. This is now possible with SRG/eROSITA, which completed its first all-sky X-ray survey (eRASS1) on June 12, 2020. The public Data Release 1 (DR1, Jan 31, 2024) includes 930,203 sources from the western Galactic hemisphere. Aims. The data enable the selection of a large AGN sample and the discovery of rare sources. However, scientific return depends on accurate characterisation of the X-ray emitters, requiring high-quality multi-wavelength data. This paper presents the identification and classification of optical and infrared counterparts to eRASS1 sources. Methods. Counterparts to eRASS1 X-ray point sources were identified using Gaia DR3, CatWISE2020, and Legacy Survey DR10 (LS10) with the Bayesian NWAY algorithm and trained priors. Sources were classified as Galactic or extragalactic via a machine-learning model combining optical/IR and X-ray properties, trained on a reference sample. For extragalactic LS10 sources, photometric redshifts were computed using CIRCLEZ. Results. Within the LS10 footprint, all 656,614 eROSITA/DR1 sources have at least one possible optical counterpart; ∼570 000 are extragalactic and likely AGN. Half are new detections compared to AllWISE, Gaia, and Quaia AGN catalogues. Gaia and CatWISE2020 counterparts are less reliable, due to the survey’s shallowness and the limited amount of features available to assess the probability of being an X-ray emitter. In the Galactic plane, where the overdensity of stellar sources also increases the chance of associations, using conservative reliability cuts, we identified approximately 18 000 Gaia and 55 000 CatWISE2020 extragalactic sources. Conclusions. We have released three high-quality counterpart catalogues – plus the training and validation sets – as a benchmark for the field. These datasets have many applications, but in particular, they empower researchers to build AGN samples tailored for completeness and purity, accelerating the hunt for the Universe’s most energetic engines.

X-rays: general↗

Slag monitoring system for combustion chambers of steam boilers

The computer-based boiler performance system presented in this article has been developed to provide a direct and quantitative assessment of furnace and convective surface cleanliness. Temperature, pressure, and flow measurements and gas analysis data are used to perform heat transfer analysis in the boiler furnace and evaporator. Power boiler efficiency is calculated using an indirect method. The on-line calculation of the exit flue gas temperature in a combustion chamber allows for an on-line heat flow rate determination, which is transferred to the boiler evaporator. Based on the energy balance for the boiler evaporator, the superheated steam mass flow rate is calculated taking into the account water flow rate in attemperators. Comparing the calculated and the measured superheated steam mass flow rate, the effectiveness of the combustion chamber water walls is determined in an on-line mode. Soot-blower sequencing can be optimized based on actual cleaning requirements rather than on fixed time cycles contributing to lowering of the medium usage in soot blowers and increasing of the water-wall lifetime.

20 FOSSIL-FUELED POWER PLANTS↗

Lower bias, lower noise CMB lensing with foreground-hardened estimators

Extragalactic foregrounds in temperature maps of the cosmic microwave background (CMB) severely limit the ability of standard estimators to reconstruct the weak lensing potential. These foregrounds are not fully removable by multifrequency cleaning or masking and can lead to large biases if not properly accounted for. For foregrounds made of a number of unclustered point sources, an estimator for the source amplitude can be derived and deprojected, removing any bias to the lensing reconstruction. We show with simulations that all of the extragalactic foregrounds in temperature can be approximated by a collection of sources with identical profiles, and that a simple bias hardening technique is effective at reducing any bias to lensing, at a minimal noise cost. In this work, we compare the performance and bias to other methods such as "shear-only" reconstruction, and discuss how to jointly deproject any arbitrary number of foregrounds, each with an arbitrary profile. In particular, for a Simons Observatory-like experiment foreground-hardened estimators allow us to extend the maximum multipole used in the reconstruction, increasing the overall statistical power by ~50% over the standard quadratic estimator, both in auto and cross-correlation. We conclude that source hardening outperforms the standard lensing quadratic estimator both in auto- A nd cross-correlation, and in terms of lensing signal-to-noise and foreground bias.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 16-yr Comparison of Fine Particle and Aerosol Strong Acidity at the Interface Zone (1,540 m) and Within (452 m) the Planetary Boundary Layer of the Great Gulf and Presidential-Dry River Class I Wildernesses on the Presidential Range, New Hampshire

Mount Washington, NH in the White Mountain National Forest, is flanked to the north-northeast and south by two Class I Wilderness areas, the Great Gulf and Presidential Range-Dry River Wildernesses, respectively. The Clean Air Act protects Class I area natural resource values from air pollution. Aerosol sulfate, a fine particulate component that is often transported long distances, is a known contributor to visibility degradation and acidic deposition. We examined summertime fine particulate aerosol mass and sulfate, strong acidity and ammonium concentrations from 1988 to 2004 on Mount Washington at two elevations, 452 and 1,540 meters (msl). The former site is within, and the latter at the interface of, the planetary boundary layer. Comparisons of sampling interval durations (10 and 24 hours), site vs. site, and different sampling methods are made. We also examine the extent to which aerosol sulfate is neutralized. Ten hour (daytime) compared to 24 hour samples have higher mass and aerosol sulfate concentrations, however paired samples are well correlated. Fine mass concentrations compared between the 452 m and 1,540 m sites (standard temperature and pressure corrected) show a weak positive linear relationship with the later being approximately 34% lower. We attribute the lack of a strong correlation to the facts that the 1,540 m site is commonly at the interface of and even above the regional planetary boundary layer in summer and that it can intercept different air masses relative to the 452 m site. Sulfate is approximately 19% lower at the higher elevation site, but comprises a greater percentage of total fine mass; 42% compared to 35% for the high and low elevation site, respectively. Aerosol strong acidity was found to increase with increasing sulfate concentrations at both sites. At the high elevation site, elevated mass and sulfate concentrations are associated with westerly and southwesterly regional flows.

Murray, Georgia L.↗

A STUDY ON LEGIONELLA PNEUMOPHILA, WATER CHEMISTRY, AND ATMOSPHERIC CONDITIONS IN COOLING TOWERS AT THE SAVANNAH RIVER SITE

Legionnaires disease is a pneumonia caused by the inhalation of the bacterium Legionella pneumophila. The majority of illnesses have been associated with cooling towers since these devices can harbor and disseminate the bacterium in the aerosolized mist generated by these systems. Historically, Savannah River Site (SRS) cooling towers have had occurrences of elevated levels of Legionella in all seasons of the year and in patterns that are difficult to predict. Since elevated Legionella in cooling tower water are a potential health concern a question has been raised as to the best control methodology. In this work we analyze available chemical, biological, and atmospheric data to determine the best method or key parameter for control. The SRS 4Q Industrial Hygiene Manual, 4Q-1203, 1 - G Cooling Tower Operation and the SRNL Legionella Sampling Program, states that 'Participation in the SRNL Legionella Sampling Program is MANDATORY for all operating cooling towers'. The resulting reports include L. pneumophila concentration information in cells/L. L. pneumophila concentrations >10{sup 7} cells/L are considered elevated and unsafe so action must be taken to reduce these densities. These remedial actions typically include increase biocide addition or 'shocking'. Sometimes additional actions are required if the problem persists including increase tower maintenance (e.g. cleaning). Evaluation of 14 SRS cooling towers, seven water quality parameters, and five Legionella serogroups over a three-plus year time frame demonstrated that cooling tower water Legionella densities varied widely though out this time period. In fact there was no one common consistent significant variable across all towers. The significant factors that did show up most frequently were related to suspended particulates, conductivity, pH, and dissolved oxygen, not chlorine or bromine as might be expected. Analyses of atmospheric data showed that there were more frequent significant elevated Legionella concentrations when the dew point temperature was high--a summertime occurrence. However, analysis of the three years of Legionella monitoring data of the 14 different SRS Cooling Towers demonstrated that elevated concentrations are observed at all temperatures and seasons. The objective of this study is to evaluate the ecology of L. pneumophila including serogroups and population densities, chemical, and atmospheric data, on cooling towers at SRS to determine whether relationships exist among water chemistry, and atmospheric conditions. The goal is to more fully understand the conditions which inhibit or encourage L. pneumophila growth and supply this data and associated recommendations to SRS Cooling Tower personnel for improved management of operation. Hopefully this information could then be used to help control L. pneumophila growth more effectively in SRS cooling tower water.

54 ENVIRONMENTAL SCIENCES↗

Simulated performance of biomass gasification based combined power and refrigeration plant for community scale application

Thermal performance analysis and sizing of a biomass gasification based combined power and refrigeration plant (CPR) is reported in this study. The plant is capable of producing 100 kWe of electrical output while simultaneously producing a refrigeration effect, varying from 28-68 ton of refrigeration (TR). The topping gas turbine cycle is an indirectly heated all-air cycle. A combustor heat exchanger duplex (CHX) unit burns producer gas and transfer heat to air. This arrangement avoids complex gas cleaning requirements for the biomass-derived producer gas. The exhaust air of the topping GT is utilized to run a bottoming ammonia absorption refrigeration (AAR) cycle via a heat recovery steam generator (HRSG), steam produced in the HRSG supplying heat to the generator of the refrigeration cycle. Effects of major operating parameters like topping cycle pressure ratio (r{sub p}) and turbine inlet temperature (TIT) on the energetic performance of the plant are studied. Energetic performance of the plant is evaluated via energy efficiency, required biomass consumption and fuel energy savings ratio (FESR). The FESR calculation method is significant for indicating the savings in fuel of a combined power and process heat plant instead of separate plants for power and process heat. The study reveals that, topping cycle attains maximum power efficiency of 30%in pressure ratio range of 8-10. Up to a certain value of pressure ratio the required air flow rate through the GT unit decreases with increase in pressure ratio and then increases with further increase in pressure ratio. The capacity of refrigeration of the AAR unit initially decreases up to a certain value of topping GT cycle pressure ratio and then increases with further increase in pressure ratio. The FESR is found to be maximized at a pressure ratio of 9 (when TIT=1100°C), the maximum value being 53%. The FESR is higher for higher TIT. The heat exchanger sizing is also influenced by the topping cycle pressure ratio and GT-TIT.

09 BIOMASS FUELS↗

Automated identification of 2612 LATE-K and M dwarfs in the lamost commissioning data using classification template fits

We develop a template-fit method to automatically identify and classify late-type K and M dwarfs in spectra from the Large Sky Area Multi-object Fiber Spectroscopic Telescope (LAMOST). A search of the commissioning data, acquired in 2009–2010, yields the identification of 2612 late-K and M dwarfs. The template fit method also provides spectral classification to half a subtype, classifies the stars along the dwarf–subdwarf (dM/sdM/esdM/usdM) metallicity sequence, and provides improved metallicity/gravity information on a finer scale. The automated search and classification is performed using a set of cool star templates assembled from the Sloan Digital Sky Survey spectroscopic database. We show that the stars can be efficiently classified despite shortcomings in the LAMOST commissioning data which include bright sky lines in the red. In particular we find that the absolute and relative strengths of the critical TiO and CaH molecular bands around 7000 Å are cleanly measured, which provides accurate spectral typing from late-K to mid-M, and makes it possible to estimate metallicity classes in a way that is more efficient and reliable than with the use of spectral indices or spectral-index based parameters such as ζ{sub TiO/CaH}. Most of the cool dwarfs observed by LAMOST are found to be metal-rich dwarfs (dM). However, we identify 52 metal-poor M subdwarfs (sdM), 5 very metal-poor extreme subdwarfs (esdM) and 1 probable ultra metal-poor subdwarf (usdM). We use a calibration of spectral type to absolute magnitude and estimate spectroscopic distances for all the stars; we also recover proper motions from the SUPERBLINK and PPMXL catalogs. Our analysis of the estimated transverse motions suggests a mean velocity and standard deviation for the UVW components of velocity to be: 〈U〉=−9.8 km s{sup −1}, σ{sub U} = 35.6 km s{sup −1}; 〈V〉=−22.8 km s{sup −1}, σ{sub V}=30.6 km s{sup −1}; 〈W〉=−7.9 km s{sup −1}, σ{sub W} = 28.4 km s{sup −1}. The resulting values are in general agreement with previous reported results, which yields confidence in our spectral classification and spectroscopic distance estimates, and illustrates the potential for using LAMOST spectra of K and M dwarfs for investigating the chemo-kinematics of the local Galactic disk and halo.

79 ASTRONOMY AND ASTROPHYSICS↗

Formally Verified ZTA Requirements for OT/ICS Environments with Isabelle/HOL: Preprint

The clean energy transformation led to the integration of distributed energy resources on a top of the grid, and so a substantial increase in the complexity of power grids infrastructure and the underlying operational technology environment. Operational technology environments are becoming a system of systems, integrating heterogeneous devices which are software/hardware intensive, have ever increasing demands to exploit advances in commodity of software/hardware infrastructures, and this for good reasons - improving energy systems requirements such as cybersecurity and resilience. In such a setting, system requirements at different levels mix, thus undesirable outcomes will surely happen. The use of formal methods will remove ambiguity, increase automation and provide high levels of assurance and reliability. In this paper, we contribute a methodology and a framework for the system level verification of zero trust architecture requirements in operational technology environments. We define a formal specification for the core functionalities of operational technology environments, the corresponding invariants, and security proofs. Of particular note is our modular approach for the formal verification of asynchronous interactions in operational technology environments. The formal specification and the proofs have been mechanized using the interactive theorem proving environment Isabelle/HOL.

formal methods↗

Decontamination of urban surfaces contaminated with radioactive materials and consequent onsite recycling of the waste water

Enhancing rapid remediation strategies is paramount for recovery after a large-scale nuclear contamination event in an urban environment. Some current strategies recommend use of readily available equipment, materials, and facilities to expedite recovery. For example, applying pressurized water to contaminated surfaces may effectively remove radioactive contamination. In this study, a commercial power washer removes soluble forms of 152 Eu 3 + , 85 Sr 2 + , and 137 Cs + contamination from common porous building materials, and computer simulations characterize the recycling of the resultant contaminated wash water. Pressure washing the porous building materials under spray conditions typical with do-it-yourself units improved decontamination factors (DFs) for 152 Eu compared to low-pressure application of tap water (majority of two-tailed t-test p-values < 0.1), but pressure did not improve DFs for 137 Cs or 85 Sr. For both pressurized and low-pressure applications, adding potassium ions (K + ) to promote ion exchange reactions produced significantly higher DFs for tested radionuclides on asphalt, brick, and concrete. The resultant contaminated wash water can be processed through self-prepared chemical filtration beds of clay and sand. Modeled in a prior study, the beds yielded linear trends (R 2 > 0.98) in sensitivity analyses between most bed configuration variables and bed performance variables, permitting flexible ad-hoc bed design. The experimental and simulation results led to estimates of the remediation rate and waste generated after cleaning 250 m 2 of cesium-contaminated concrete from the combined deployment of a power washer and two different mobile treatment beds. Furthermore, the first treatment bed was designed to reduce treatment time and processed 1900 L of wash solution in 70 min using 880 kg of clay/sand infill material. Designed to reduce the solid waste generated, the second bed processed the same solution volume in 1040 min (17 h) using 170 kg of clay/sand infill material. The results of this analysis warrant further investigation of power washing with recycled salt solution as an effective rapid decontamination method with manageable waste.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Feature Engineering and Ensemble Methods for Imbalanced ICS Intrusion Detection: Pipeline Audit and Constrained Evaluation

Industries are becoming increasingly connected and are more vulnerable to cyberattacks due to the widened attack surface. Industrial Control Systems (ICS) are among the most critical sectors that malicious actors can target, as such attacks can cause significant operational disruption and physical damage. It is imperative to detect such attacks as early as possible. This paper evaluates constraint-conditioned optimistic performance estimates for traditional ML models in ICS intrusion detection (i.e., estimates obtained under contiguous, non-shuffled temporal evaluation without test-set alteration, but with pre-split feature engineering that may introduce temporal leakage, due to dataset constraints). Our findings are threefold. First, we quantify how iterative feature engineering affects tree-based ensemble performance and examine how pipeline decisions (split strategy, sampling scope, and cleaning policy) can inflate or reduce reported IDS results under constraint-bound evaluation. Second, we compare intrinsic class-imbalance handling across ensemble models. Third, under our current pipeline constraints (including pre-split feature engineering), CatBoost achieves the best performance on Water Storage Tank (accuracy: 0.9831, class-1 F1: 0.9682), while Light- GBM achieves the best performance on Gas Pipeline (accuracy: 0.9618, class-1 F1: 0.9086).

97 MATHEMATICS AND COMPUTING↗

Energy Northwest — Advanced Grid Interactive Load Efficiency (AGILE) : A Techno-economic Assessment

The Advanced Grid Interactive Load Efficiency project team, led by Energy Northwest, was awarded funding as part of the fourth round of the Clean Energy Fund program to investigate, co-create, and complete a preliminary design for grid-interactive efficient buildings (GEBs) for a number of schools served by Grays Harbor PUD. The project team has evaluated different combinations of systems at selected school buildings and the potential to respond to grid and customer needs, and develop a preliminary system technical design, including specifying desired GEB technology options, determining communication and electrical interface requirements, assessing control software sensor requirements, and interfacing with building management systems. PNNL led the techno-economic assessment efforts, leveraging its advanced modeling and analytical methods and tools developed for building-to-grid integration. This report documents the economic assessment for different GEB design options, encompassing an in-depth examination of use cases and value propositions, assumptions and inputs, models, methods, case studies, as well as key findings.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geo-polymer solidification technology approved by Czech / Slovak nuclear authority to immobilise NPP resins and sludge waste - 15555

This paper presents the features and performance record of the geo-polymer solidification technology, SIAL{sup R}, licensed for use by both the Slovakian (UJD SR) and Czech Nuclear (SUJB) regulators. An overview of its performance at Bohunice in Slovakia, where it has been used to successfully treat resins and sludge wasteforms will be provided along with references to other plants where it has been used. More recently, geo-polymers have been noted as an immobilization technology which shows potential for resins produced by treatment of radioactive contaminated water resulting from the clean-up of the Fukushima Daiichi Plant. The Nuclear Power Plant A-1 located in Jaslovske Bohunice was completed in 1972 and operated for 5 years until two accidents in 1976 and 1977. After the second accident in February 1977 (INES level 4) the Nuclear Power Plant was permanently shut down for decommissioning. Fuel assemblies and fuel cladding damaged in the accidents led to significant Sr-90, Cs-137 and transuranic contamination. As a consequence of the long-term corrosion of the barrier's material, highly contaminated sludge accumulated which could not be effectively immobilized using conventional methods such as cementation or bitumen treatment due to adverse physical-chemical properties and high specific activity of the waste (Cs-137). This challenge led to AMEC developing and licensing the geo-polymer, SIAL{sup R}. Today, this geo-polymer is one of the most proven and widely used for on-site solidification of radioactive materials such as sludge, resins, sorbents and organic liquids. There are numerous benefits to using this geo-polymer for waste immobilisation. It can be used at room temperature and can incorporate up to approximately four times as much waste (sludge, resin) as a Portland cement matrix equivalent depending on the waste being treated. In addition, it is characterized by excellent mechanical and physical properties, compared with the earlier generation techniques. This includes higher mechanical strength, lower leachability, low volatility, posing a low fire risk and excellent physical stability in the presence of frost and water (no distortion or cracking). Dedicated facilities to receive and encapsulate waste from different locations can be created but this geo-polymer can also provide efficient and practical on-site treatment of radioactive waste streams. This is achievable because the equipment used to encapsulate waste using SIAL{sup R} is also modular, flexible and versatile. At Bohunice, the facility for encapsulation was designed to occupy existing areas of the plant in close proximity to the tanks where the waste was being stored. This allowed for the removal of the waste using Remote Operated Vehicles (ROVs) and for the waste to be immediately treated on site without the need for transportation saving both time and resource. To achieve this, some of the rooms and areas of the building were assessed and modified to ensure that the waste package flow was suitable whilst ensuring that appropriate safety measures were in place such as adequate shielding to reduce or entirely eliminate dose uptake of workers. To date, SIAL{sup R} has been used to successfully immobilize approximately 500 tons of waste which includes sludge and resin from Bohunice, Slovakia and approximately 250 m{sup 3} of spent ion exchange resins from tanks on site at the Dukovany nuclear plant, Czech Republic. It now has a track record of over 15 years which includes on-going research and development. The International missions WANO and OSART evaluated the SIAL{sup R} matrix technology at NPP Dukovany as an example of good practice. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Spectroscopic Analysis of Pu-bearing Compounds in Double-Walled Cells

Spectroscopic analysis of radiological materials has been historically limited to radiological labs with 11 older or less advanced scientific instrumentation. The development of double-walled cells (DWCs) at 12 the Savannah River National Laboratory (SRNL) has enabled Pu-bearing compounds to be removed 13 from radiological laboratories and studied in our radiologically clean spectroscopy lab with state-of14 the-art instrumentation. In this manuscript, we discuss the contributions of DWCs that have allowed 15 the application of Raman spectroscopy, diffuse reflectance infrared Fourier transform spectroscopy 16 (DRIFTS), diffuse reflectance spectroscopy (DRS) in the shortwave infrared, and gamma 17 spectroscopy at SRNL. Significant advances have been made in the understanding of thermal 18 decomposition of Pu(III) and Pu(IV) oxalates, the alpha-induced damage to the PuO2 crystal lattice, 19 and the effect of calcination temperatures to the quality of PuO2. These techniques have enabled 20 methods to conduct PuO2 age dating since last calcination and estimate the calcination temperature 21 with Raman and DRS. Additional spectroscopic information measured with DRIFTS has provided a 22 path to observe the evolution of carbon species with calcination temperature while gamma 23 spectroscopy provides information on age dating since last purification.

Villa-Aleman, Eliel↗