Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed control and optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Advanced truck and bus radial materials for fuel efficiencies (Final Report)

PPG Industries, Inc. and Bridgestone Americas Tire Operations (BATO) propose to develop a novel surface-modified silica technology and demonstrate 4-6% improved fuel efficiency of Truck and Bus Radial (TBR) tires built from the technology. The proposed fuel efficiency increase will be achieved while maintaining or improving tear strength and tread wear. During rubber mixing, distributing silica in the rubber matrix is a challenge. This is because silica has a very polar surface, while rubbers have little polarity. It was hypothesized that surface treatments could cover part of the surface by hydrophobic groups, and reduce the surface polarity, thus helping to wet the silica with rubber during mixing and improving silica dispersion. During the project, the effect of different silica surface treatments on the surface energy of silica were determined, and related to the silica dispersion in rubber compounds. The results demonstrated that reducing the surface energy of silica samples improved dispersion in rubber compounds. Also, the preference for silica to migrate to the different phases in polymer blends was determined. The studies performed in binary polymer blends showed that carbon black has a preference to distribute in the different polymer phases in the order: SBR>BR~NR. Commercially available silica samples (treated and untreated) showed a preference in the order of SBR>NR>BR. Finally, the silica prototypes showed a preference in the order SBR=NR>BR. The knowledge gained regarding dispersion of treated silicas in rubber compounds was used to perform a series of studies to develop a silica – rubber compound combination with optimum performance for TBR treads. Initially, two silica prototypes (BXR-990 and BXR-991) were developed and used for a tire build at BATO’s tire plant in Warren County, TN. Results were evaluated and further silica and compound optimization was performed, prior to a final tire build. Manufacturing of the final silica prototype (BXR-1006) for the final tire build was performed at the PPG Silicas Pilot Plant in Monroeville, PA. Afterwards, experimental tires with silica-filled treads and control tires with carbon black-filled treads were built at BATO’s Warren County tire plant. The experimental TBR tires with silica-filled treads achieved the project goals for lab performance indicators, tread hardness and tear strength. The tires showed a 2.2% improvement in fuel efficiency compared to the control tires. While this improvement is lower than the 4% goal set initially, the improvement is significant and there are indicators that up to a 5% improvement in fuel efficiency could be achieved. This is supported by the confirmation of the validity of the fuel efficiency indicators made at the beginning of the project, and by the improvement in hysteresis and rolling resistance from tires built earlier in the project. The experimental tires produced using the BXR-990 silica prototype showed 47% improvement in tan δ at 60°C and 16% improvement in rolling resistance. Based on the results obtained, it is valid to estimate that the tires built with BXR-990 could provide around a 5% improvement in fuel efficiency, should we perform a fuel efficiency test. Tire wear for the experimental tires was 31% worse than for the control tires with the carbon black-filled tread compound. Other tools and further analysis of factors affecting wear are necessary to be evaluated to produce a silica tire with wear comparable to carbon black. Experimental and control tires were provided to the DOE for independent testing.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Rapid SACR Observations of Convection at Bankhead National Forest (RAPID) Field Campaign Report

Improving our representation of convective cell processes requires better quantification of convective clouds throughout their entire life cycle. This includes gaining a clearer understanding of the controls on key convective cloud properties, such as updraft intensity, particle size distributions, rainfall rates, and hydrometeor species. Our inability to improve convective cloud process modeling stems, in part, from a limited understanding of convective cell properties, particularly given how rapidly these storms evolve. This lack of detailed observations in the most intense and organized convective storms is especially significant, as large errors remain in representing these clouds, which are critical for severe weather prediction and Earth system model performance. Cloud and precipitation radars are essential tools for studying cloud microphysics and dynamics, particularly in deeper convective clouds. The recent U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s third Mobile Facility (AMF3) Bankhead National Forest (BNF) deployment provides a unique opportunity to investigate important land–atmosphere interactions, as well as the environmental controls on deep convective cloud processes, in a location favorable for frequent convection. We operate the X/Ka-band Scanning ARM Cloud Radar (X/Ka SACR) using a scan strategy optimized to capture these rapidly evolving clouds and their properties, thereby improving studies of deep convective cloud processes. This effort is strengthened by a complementary and coordinated partnership with ongoing university and multi-agency radar activities collocated in north Alabama—a unique opportunity to examine clouds and precipitation from a lifetime-centric perspective.

54 ENVIRONMENTAL SCIENCES↗

A Generation-Storage Coordination Dispatch Strategy for Power System Based on Causal Reinforcement Learning

In the backdrop of global energy transformation, power systems integrating high proportions of renewable energy sources are facing unprecedented challenges in operational stability and dispatch efficiency. To address these challenges, this study introduces a generation-storage coordination real-time dispatch strategy based on Causal Power System Dynamic Reinforcement Learning (CPSDRL). Diverging from traditional reinforcement learning approaches, CPSDRL innovatively incorporates causal inference within the state prediction model - the crux of model-based reinforcement learning - thereby establishing the Power Causal Dynamic Model (PCDM). Assisted by the prior knowledge of power systems, the model significantly enhances prediction accuracy and reliability through a two-stage training process. Utilizing PCDM, this study further applies a direct policy search algorithm to optimize the real-time dispatch strategy. Experimental results indicate that the proposed method improves the stability of generation-storage coordination real-time dispatch and exhibits competitive advantages in sample efficiency and computational speed, compared to traditional model-based and model-free reinforcement learning algorithms. This method is expected to enhance the practicality and adaptability of causal reinforcement learning techniques in power system scheduling and control.

causal reinforcement learning↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Treatment of Oral Cavity Squamous Cell Carcinoma With Adjuvant or Definitive Intensity-Modulated Radiation Therapy

Purpose: The optimal management of oral cavity squamous cell carcinoma (OCSCC) typically involves surgical resection followed by adjuvant radiotherapy or chemoradiotherapy (CRT) in the setting of adverse pathologic features. Intensity-modulated radiation therapy (IMRT) is frequently used to treat oral cavity cancers, but published IMRT outcomes specific to this disease site are sparse. We report the Dana-Farber Cancer Institute experience with IMRT-based treatment for OCSCC. Methods and Materials: Retrospective study of all patients treated at Dana-Farber Cancer Institute for OCSCC with adjuvant or definitive IMRT between August 2004 and December 2009. The American Joint Committee on Cancer disease stage criteria distribution of this cohort included 5 patients (12%) with stage I; 10 patients (24%) with stage II (n = 10, 24%),; 14 patients (33%) with stage III (n = 14, 33%),; and 13 patients (31%) with stage IV. The primary endpoint was overall survival (OS); secondary endpoints were locoregional control (LRC) and acute and chronic toxicity. Results: Forty-two patients with OCSCC were included, 30 of whom were initially treated with surgical resection. Twenty-three (77%) of 30 surgical patients treated with adjuvant IMRT also received concurrent chemotherapy, and 9 of 12 (75%) patients treated definitively without surgery were treated with CRT or induction chemotherapy and CRT. With a median follow-up of 2.1 years (interquartile range, 1.1-3.1 years) for all patients, the 2-year actuarial rates of OS and LRC following adjuvant IMRT were 85% and 91%, respectively, and the comparable results for definitive IMRT were 63% and 64% for OS and LRC, respectively. Only 1 patient developed symptomatic osteoradionecrosis, and among patients without evidence of disease, 35% experienced grade 2 to 3 late dysphagia, with only 1 patient who was continuously gastrostomy-dependent. Conclusions: In this single-institution series, postoperative IMRT was associated with promising LRC, OS, and lower late toxicity rates, and chemoradiotherapy was a successful treatment for patients with high-risk disease. In contrast, outcomes of radiation-based treatment for patients with inoperable locally advanced disease were markedly less successful.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 4DCT imaging-based breathing lung model with relative hysteresis

To reproduce realistic airway motion and airflow, the authors developed a deforming lung computational fluid dynamics (CFD) model based on four-dimensional (4D, space and time) dynamic computed tomography (CT) images. A total of 13 time points within controlled tidal volume respiration were used to account for realistic and irregular lung motion in human volunteers. Because of the irregular motion of 4DCT-based airways, we identified an optimal interpolation method for airway surface deformation during respiration, and implemented a computational solid mechanics-based moving mesh algorithm to produce smooth deforming airway mesh. In addition, we developed physiologically realistic airflow boundary conditions for both models based on multiple images and a single image. Furthermore, we examined simplified models based on one or two dynamic or static images. By comparing these simplified models with the model based on 13 dynamic images, we investigated the effects of relative hysteresis of lung structure with respect to lung volume, lung deformation, and imaging methods, i.e., dynamic vs. static scans, on CFD-predicted pressure drop. The effect of imaging method on pressure drop was 24 percentage points due to the differences in airflow distribution and airway geometry. - Highlights: • We developed a breathing human lung CFD model based on 4D-dynamic CT images. • The 4DCT-based breathing lung model is able to capture lung relative hysteresis. • A new boundary condition for lung model based on one static CT image was proposed. • The difference between lung models based on 4D and static CT images was quantified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wind and Solar Hybrid Power Plants for Energy Resilience

Wind-solar-storage hybrid power plants represent a significant and growing share of new proposed projects in the United States (U.S.). Their uptake is supported by increasing renewable energy market share, technical abilities for dispatch and control, and decreasing wind, solar, and battery storage costs. Simultaneously, generation and storage resources are increasingly used in distributed power systems. While concerns around the reliability of the aging, transforming U.S. electric grid are growing, diversifying energy resources through hybridization or spatial distribution provides an opportunity to enhance power system resilience compared to single-source generation. Understanding where to build hybrids for resilience value, rather than bulk power supply, has not been fully explored in previous studies. Therefore, in this study, we complete a national complementarity analysis to identify areas in the U.S. that are particularly suited for wind-solar hybrid power plant development. We show the importance of seasonal and diurnal patterns in assessing complementarity, and identify that regions in the Great Plains, Midwest, and Southeast are particularly suited for hybrid power plants. We demonstrate the resilience value of hybridization for a reference system based near Memphis, Tennessee, and show optimal sizing of wind, solar, and storage assets given 1.0 and 0.9 critical load factors. Results indicate that pairing wind and solar assets better meet constant load demand and reduce storage requirements compared to solar alone. These results enable future work integrating complementarity metrics in resilience frameworks and indicate a need for more finer resolution of local resource, demand, and hazard data.

14 SOLAR ENERGY↗

Controlling the sense of molecular rotation: Classical versus quantum analysis

Recently, it was predicted theoretically and verified experimentally that a pair of delayed and cross-polarized short laser pulses can create molecular ensembles with a well-defined sense of rotation (clockwise or counterclockwise). Here we provide a comparative study of the classical and quantum aspects of the underlying mechanism for linear molecules and for symmetric tops, like benzene molecules, that were used for the first experimental demonstration of the effect. Very good quantitative agreement is found between the classical description of the process and the rigorous quantum-mechanical analysis at the relevant experimental conditions. Both approaches predict the same optimal values for the delay between pulses and the angle between them, and deliver the same magnitude of the induced oriented angular momentum of the molecular ensemble. As expected, quantum and classical analyses substantially deviate when the delay between pulses is comparable with the period of quantum rotational revivals. However, time-averaged characteristics of the excited molecular ensemble are equally well described by these two approaches. This is illustrated by calculating the anisotropic time-averaged angular distribution of the double-pulse excited molecules, which reflects persistent confinement of the molecular axes to the rotation plane defined by two polarization vectors of the pulses.

74 ATOMIC AND MOLECULAR PHYSICS↗

Silane injection in a high-density low-pressure plasma system and its influence on the deposition kinetics and material properties of SiO{sub 2}

High-rate, low temperature deposition is an essential requirement for industrial fabrication technology to be suitable for the deposition of optical and protective coatings. High-density, low-pressure plasmas have received significant attention for such applications due to their ability to create large and controllable ion fluxes onto the substrate. In this study, the high-rate deposition of silica films from a silane and oxygen gas mixture in a high-density plasma system based on a matrix distributed electron cyclotron resonance (MDECR) plasma source is investigated using directional jet injection of undiluted silane. The influence of process parameters such as the microwave power, radio frequency biasing of the substrate holder, and gas flows on the OH content of the oxide films is studied using phase-modulated spectroscopic ellipsometry (SE), Fourier transform infrared (FTIR) spectroscopy, and transmission measurements. The results of the measurements, taken at various points across the wafer, show a decrease in the thickness-normalized OH concentration in the areas of higher deposition rates. The corresponding gas phase composition is investigated using optical emission spectroscopy and compared to the FTIR, transmission and SE measurement results in order to validate our findings and ultimately optimize the deposition process. It is found that the primary silane flux onto the surface, which depends on the positioning of the jet injection point and gas flow rate, plays an important role not only on the deposition rate but also on the OH content of the films. The authors conclude that high-density plasma deposition systems such as the MDECR plasma enhanced chemical vapor deposition system cannot be considered as well mixed for gases with dissociation products that have high sticking coefficients, contrary to the accepted paradigm.

36 MATERIALS SCIENCE↗

Coordinated Modeling of Electric Grid and Natural Gas Network Operations

Presentation based upon full report of a Colorado case study and coordination framework, which is available at https://www.nrel.gov/docs/fy20osti/77096.pdf. JISEA analysts Brian Sergi, Omar Guerra, and Bri-Mathias Hodge will present on recent JISEA work on coordination between the natural gas and electricity sectors. Power and gas are becoming increasingly interdependent but weren't designed to function together. How does greater coordination impact system operations with different levels of solar and wind penetrations? This free JISEA presentation will take place in a Webinar on Tuesday, May 11, 2021 at 12 p.m.: Learn how greater coordination between the natural gas and electricity sectors impacts system operations with different levels of solar and wind penetrations. Presentation information includes: Historical and projected data for natural gas consumption and power generation in the United States as demonstrated by 2014 East Coast Polar Vortex, 2021 Texas Winter Storm Uri. Showing coupling points, FERC identified need for better coordination, different levels of coordination (decision making and optimization control), coordination framework. Case study on Colorado Front Range, ramping requirements and gas nominations, real-time dispatch (June and December scenarios), results of analysis of impacts of coordination on unserved load. Total real-time gas offtakes by node, impacts on unserved gas, effect on CO2 emissions. Discussions on clusions drawn from Colorado Case study expanded co-simulation via HELICS, objectives of the HELICS+ natural gas use case, modeling of hydrogen blending, techno economic assessment of blending, and blending impacts on energy content and pressure.

analysis↗

Simulation and Controls for Heavy Duty Dual Mode Hybrid Powertrain (Final CRADA Report)

Hybrid powertrains are of considerable interest because of potential reductions in fuel consumption, criteria pollutants and green house gas (GHG) emissions. Parallel hybrids have been applied to light and medium duty trucks, where urban driving cycles are prevalent, while series hybrids have been successfully used for other applications like transit and school buses. Unfortunately, hybridization of the Class 8, heavy-duty (HD) powertrain is inherently challenging due the expected long-haul driving requirements and limited opportunities for regenerative braking. The Participant has conceived and demonstrated a transformational Dual Mode Hybrid Powertrain (DMHP) technology developed specifically for the needs and function of Class 8 line haul trucks. The DMHP system enables a new paradigm in powertrain operational efficiency in the Class 8 truck segment. It decouples the connection between the engine operating point and the truck road load demands over a broad operating range through an innovative hybrid design. The DMHP operation choices include running in full series, full parallel and engine-off modes. The DMHP offers the opportunity for an engine to operate in a narrow range, thus providing a strategy for maximized fuel economy and minimized emissions. Further, it is expected that transient torque and power wheel demands are handled in whole or part by the electric system, thus reducing the frequency and intensity of engine transients and further improving the fuel economy and emissions. Fuel consumption and emissions have been further reduced through the elimination of overnight hoteling and idling at stops. Finally, based on the unique operating profile of an engine integrated into our hybrid powertrain, a transformational HD truck engine design concept next can emerge. Recent research activities by Oak Ridge National Laboratory (ORNL) have yielded significant data in real-life speed and load profiles of Class 8, long haul trucks. In addition, preliminary simulations of the DMHP carried out by ORNL reveal significant optimization opportunities of the DMHP by applying systematic simulation and controls approaches. An improved understanding of the complex interactions offered by the on-board engine, energy storing system, and electric machines is necessary for the development of control methodologies and practical implementation. We will continue to further this understanding through detailed experimentation and modeling, drawing on and expanding ORNL’s core competency in basic engine research and development (R&D) and advanced controls. This knowledge will be used to develop, implement, and evaluate control strategies on an actual DMHP using Meritor’s components and subsystems. Our initial focus will be on optimization of DMHP utilizing a “stock” diesel engine that is commercially available in the market place. A new DMHP-specific engine design concept will be pursued at a later phase of this Cooperative Research and Development Agreement (CRADA). Meritor will develop the experimental setup, conduct sub-system experiments at their facility, and implement and evaluate potential control strategies resulting from this CRADA partnership. Oak Ridge National Laboratory (ORNL) will develop a real-time simulation model for use in real-time control of the DMHP. The model and potential algorithms will be evaluated on a HD, hybrid powertrain dynamometer facility that will also be developed at the ORNL Vehicle Systems Integration facility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

MO-AB-BRA-01: A Global Level Set Based Formulation for Volumetric Modulated Arc Therapy

Purpose: The current clinical Volumetric Modulated Arc Therapy (VMAT) optimization is formulated as a non-convex problem and various greedy heuristics have been employed for an empirical solution, jeopardizing plan consistency and quality. We introduce a novel global direct aperture optimization method for VMAT to overcome these limitations. Methods: The global VMAT (gVMAT) planning was formulated as an optimization problem with an L2-norm fidelity term and an anisotropic total variation term. A level set function was used to describe the aperture shapes and adjacent aperture shapes were penalized to control MLC motion range. An alternating optimization strategy was implemented to solve the fluence intensity and aperture shapes simultaneously. Single arc gVMAT plans, utilizing 180 beams with 2° angular resolution, were generated for a glioblastoma multiforme (GBM), lung (LNG), and 2 head and neck cases—one with 3 PTVs (H&N3PTV) and one with 4 PTVs (H&N4PTV). The plans were compared against the clinical VMAT (cVMAT) plans utilizing two overlapping coplanar arcs. Results: The optimization of the gVMAT plans had converged within 600 iterations. gVMAT reduced the average max and mean OAR dose by 6.59% and 7.45% of the prescription dose. Reductions in max dose and mean dose were as high as 14.5 Gy in the LNG case and 15.3 Gy in the H&N3PTV case. PTV coverages (D95, D98, D99) were within 0.25% of the prescription dose. By globally considering all beams, the gVMAT optimizer allowed some beams to deliver higher intensities, yielding a dose distribution that resembles a static beam IMRT plan with beam orientation optimization. Conclusions: The novel VMAT approach allows for the search of an optimal plan in the global solution space and generates deliverable apertures directly. The single arc VMAT approach fully utilizes the digital linacs’ capability in dose rate and gantry rotation speed modulation. Varian Medical Systems, NIH grant R01CA188300, NIH grant R43CA183390.

60 APPLIED LIFE SCIENCES↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photovoltaic Analysis and Response Support (PARS) Platform for Solar Situational Awareness and Resiliency Services

The project's primary objective is to develop a digital-twin based Photovoltaic (PV) Analysis and Response Support (PARS) platform, which aims to provide real-time situational awareness and optimal response plans. This platform is designed to enhance the performance of hybrid PV systems, making them competitive with or even superior to conventional generation resources. The PARS platform enabled the project team to develop and evaluate an extensive suite of grid support functionalities for the hybrid PV systems to enhance grid performance, across key areas including visibility, dispatchability, security, resilience, and reliability. Given the global push toward achieving 100% clean energy by 2035, there is a significant increase in the integration of inverter-based resources (IBRs) throughout the energy grid. Effectively managing the inherent variability and uncertainty associated with IBRs is crucial for ensuring cost-effectiveness, reliability, and security in both the main grid and islanded microgrids. Constrained to a limited array of IEEE test systems or standard feeder models, traditional IBR modeling struggles to assimilate new field data, accurately reflect system dynamics, and adapt to the evolving energy landscape. In our project, we embraced a Digital Twin (DT) strategy for crafting the PARS platform. A digital twin acts as a precise virtual counterpart of a physical system, built on historical data and continuously honed with real-time insights. This enables the high-fidelity DT to accurately mirror current system operations and forecast future scenarios. Consequently, the PARS platform becomes an ideal environment for testing and refining monitoring, control, power, and energy management algorithms designed to boost hybrid PV system performance. The defining feature of the PARS platform, distinguishing it from other advanced simulation tools, is its exceptional adaptability. This is achieved by employing actual network topologies and utilizing real-time field data for fine-tuning and calibration, ensuring a close emulation of real-world conditions. The project deliverables include: 1) High-fidelity IBR models and tools for real-time parameterization, utilizing real-time field measurements to refine IBR models for enhanced accuracy and performance; 2) Grid-forming and Grid-following capabilities to deliver resilience services, including blackstart, voltage and frequency support, cold-load pick-up, power reserves, and three-phase load balancing across grid-connected and microgrid settings; 3) Machine learning-based forecasting tools and methods for generating synthetic data and topologies, creating diverse and realistic simulation environments for evaluating varied operational scenarios; 4) Advanced microgrid power and energy management algorithms for optimizing the integration and operation of PV, storage, and demand response resources within both feeder and community scales. The power grid data sets are provided by four utility companies in North Carolina and the New York Power Administration. Acting as industry advisors, our industry partners communicated stakeholder needs and regulatory standards to the research teams, aiding technology transfer by incorporating the developed methodologies into their daily operations. This collaboration ensures that the PARS platform, functioning as a power system digital twin, enhances our understanding of IBR dynamic behaviors and enables the development and evaluation of IBR control functions that match or exceed the capabilities of conventional synchronous generators.

14 SOLAR ENERGY↗

Batch Extraction Studies to Evaluate Trace Element Behavior in PUREX Conditions

The multilab Intentional Forensics Venture is working to identify which stable elements (i.e., taggants) at trace concentrations relative to U would persist throughout the nuclear fuel cycle in a voluntary fuel tagging scheme. A taggant would provide the nuclear forensics community with a “barcode” to help identify nuclear materials found outside of regulatory control. A portion of this project was focused on reprocessing effects and determining which, if any, elements would coextract with U(VI) in standard Pu–U reduction extraction (PUREX) conditions. Elements with a propensity to coextract could, in theory, be used as taggants from a PUREX perspective. Although retention is not a performance requirement, the taggant signature would need to partition predictably from the U stream after the PUREX process to maintain forensic utility. This report documents results from several batch extraction studies with numerous trace elements from HNO 3 (1.5–5 M), with and without U(VI), into 30% tri-n-butyl phosphate (TBP) in kerosene. Extraction and back-extraction tests were used to evaluate nearly 60 elements in surrogate conditions for PUREX, and distribution coefficients (i.e., D-values) for most species were <0.1, indicating few species are likely to co-extract with U through PUREX. Additional studies are needed to optimize sample volumes and dilutions to dial in these low D-values. The D-values (D) were determined for several of the more promising elements, including Re and Se. Ultimately, we conclude that only a limited number of the ~ 60 elements investigated are extractable in the U stream of PUREX, based on measured D values, meaning most candidate elemental taggants would likely be lost at this stage of the nuclear fuel cycle, even when considering a range of acid concentrations.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

The Climate Response to Stratospheric Aerosol Geoengineering Can Be Tailored Using Multiple Injection Locations

By injecting different amounts of SO 2 at multiple different latitudes, the spatial pattern of aerosol optical depth (AOD) can be partially controlled. This leads to the ability to influence the climate response to geoengineering with stratospheric aerosols, providing the potential for design. In this work, we use simulations from the fully coupled whole-atmosphere chemistry climate model CESM1(WACCM) to demonstrate that by appropriately combining injection at just four different locations, 30°S, 15°S, 15°N, and 30°N, then three spatial degrees of freedom of AOD can be achieved: an approximately spatially uniform AOD distribution, the relative difference in AOD between Northern and Southern Hemispheres, and the relative AOD in high versus low latitudes. For forcing levels that yield 1–2°C cooling, the AOD and surface temperature response are sufficiently linear in this model so that the response to different combinations of injection at different latitudes can be estimated from single-latitude injection simulations; nonlinearities associated with both aerosol growth and changes to stratospheric circulation will be increasingly important at higher forcing levels. Optimized injection at multiple locations is predicted to improve compensation of CO 2 -forced climate change relative to a case using only equatorial aerosol injection (which overcools the tropics relative to high latitudes). The additional degrees of freedom can be used, for example, to balance the interhemispheric temperature gradient and the equator to pole temperature gradient in addition to the global mean temperature. Further research is needed to better quantify the impacts of these strategies on changes to long-term temperature, precipitation, and other climate parameters.

54 ENVIRONMENTAL SCIENCES↗

Influence of the as-built microstructure on the recrystallization of an additively manufactured Inconel939 Ni-based superalloy

This study investigates the influence of the as-built microstructure on the recrystallization (RX) behavior and mechanical properties of the Ni-based superalloy Inconel 939 produced by laser powder bed fusion (PBF-LB/M). Two distinct as-built microstructures were obtained by varying the hatch distance (h d ): a columnar, strongly textured condition (h d =50, termed h d 50) and an equiaxed, weakly textured condition (h d =70, termed h d 70)). Both were subjected to nine solution treatments combining three temperatures (1100, 1150, and 1200 °C) and three holding times (1, 4, and 8 h). Comprehensive microstructural characterization was conducted to assess grain morphology, texture, grain boundary character, dislocation density, and precipitate distribution. Recrystallization was found to be significantly slower than in cast counterparts, requiring higher temperatures and longer times for completion. The initial microstructure plays a decisive role: full RX was achieved only in hd70 specimens after treatment at 1200 °C for 8 h, whereas hd50 samples exhibited delayed and incomplete RX under identical conditions. This behavior is attributed to the finer grain size and higher fraction of high-angle grain boundaries in hd70, which promote recrystallization. Mechanical testing revealed that hd70 samples subjected to a 1200 °C/8 h treatment followed by standard double ageing show higher yield and tensile strengths across the investigated temperature range than both printed and cast Inconel939 processed under conventional conditions, albeit with slightly reduced ductility. The enhanced mechanical performance is attributed to the larger grain size, which limits grain boundary sliding. These results demonstrate the critical importance of controlling the as-built microstructure and tailoring post-processing strategies to optimize high-temperature performance of PBF-LB/M Inconel939.

Inconel939↗

Experimental and theoretical assessment of the multi-domain flow behaviour in a waste body during leachate infiltration

The optimisation of landfill operation is a key challenge for the upcoming years. A promising solution to improve municipal solid waste (MSW) management is the bioreactor technology. A meso-scale (around 1 m{sup 3}) experimental set-up was performed to study the effect of moisture control in low density conditions with different leachate injection operations and bioreactor monitoring including the use of a neutron probe. The moisture content distribution evolution demonstrates a multi-domain flow behaviour. A classic van Genuchten-Mualem description of the connected porosity proved insufficient to correctly describe the observed phenomena. A bimodal description of the connected porosity is proposed as solution and a connected/non-connected porosities numerical model was applied to the results. The model explains the experimental results reasonably well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗