Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Balancing Power Absorption and Structural Loading for a Novel Fixed-Bottom Wave Energy Converter with Nonideal Power Take-Off in Regular Waves: Preprint

In this work, the net power delivered to the grid from a nonideal power take-off (PTO) is introduced followed by a review of the pseudo-spectral control theory. A power-to-load ratio, used to evaluate the pseudo-spectral controller performance, is discussed, and the results obtained from optimizing a multiterm objective function are compared against results obtained from maximizing the net output power to the grid. Simulation results are then presented for four different oscillating wave energy converter geometries to highlight the potential of combing both geometry and PTO control to maximize power while minimizing loads.

16 TIDAL AND WAVE POWER↗

Nb3Sn Coating of Twin Axis Cavity and Other Complex SRF Cavity Structures

In the field of Accelerator Science, for the low cost and increased quality factor, thin films coated niobium cavities are used in the modern SRF research. Within the potential substances, Nb3Sn has shown higher critical temperature than niobium. Here the tin vapor diffusion method is used as the preferred technique to coat niobium cavities. So far, only elliptical cavities have been coated with Nb3Sn and this technique has not yet been applied to cavities with complex geometries, which are also helpful in the accelerator science field. The Half-wave resonator could provide us data across frequencies of interest for particle accelerators world wide. Similarly the Twin axis cavity proposed for Energy Recovary Linac (ERL) applications could benefit from Nb3Sn coating. But with their advanced geometries, increased area, more number of ports and hard to reach areas, a different coating approach is needed to provide a uniform coating of Nb3Sn. We used twin axis cavity to optimize the coating technique and followed a low temperature annealing to further improvement of the thin film quality by low temperature annealing as a post coating method. With these we could expand the current coating system at JLab to coat complex cavity models

Tiskumara, Jayendrika↗

Supportless, bismuth-modified palladium nanotubes with improved activity and stability for formic acid oxidation

Palladium nanotubes (PdNTs) were synthesized by templated vapor deposition and investigated for formic acid electrooxidation. Annealed PdNTs are 2.4 times more active (2.19 mA/cm 2 ) than commercial carbon-supported palladium (0.91 mA/cm 2 ) at 0.3 V vs RHE. Bismuth modification improved nanotube performance over 4 times (3.75 mA/cm 2 ) vs Pd/C and nearly 2 times vs unmodified PdNTs. A surface Bi coverage of 80% results in optimal site-specific activity by drastically reducing surface-poisoning CO generation during formic acid electrooxidation. The Bi-modified PdNTs are exceptionally stable, maintaining 2 times the area-normalized current density as Pd/C after 24 h at 0.2 V vs RHE. As a result, we attribute the enhanced activity and stability of the nanotube catalysts to the presence of highly coordinated surfaces, mimicking a flat polycrystal while retaining high surface area geometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AC Resistance Reduction Using Orthogonal Air Gaps in High-Frequency Inductors: Preprint

This paper presents a relatively simple technique to reduce winding losses due to fringing fields in high-frequency inductors. In high-frequency power electronics, ac inductor winding losses are affected by skin and proximity effects, including uneven current distribution due to fringing magnetic fields around airgaps. It is well known how fringing effects can be mitigated using distributed airgaps, at the expense of non-standard core or winding geometry. In planar magnetics, the orthogonal-airgap approach proposed in this paper combines airgaps in core segments parallel with the windings with conventionally placed airgaps in segments perpendicular to the windings. The approach is developed using a 1D analytical framework and validated by 2D finite-element simulations. Analytical guidelines are presented to optimize the airgaps to achieve minimum ac resistance. As a case study, a planar inductor is designed for an 8~kW SiC-based buck converter operating at 250~kHz. It is shown how the orthogonal airgaps result in more than 45\% reduction in ac resistance and substantially reduced inductor losses compared to the design using standard airgaps. The results are verified by loss measurements on an experimental converter prototype.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Inversion of infrared imaging bolometer based on one-dimensional and three-dimensional modeling in HL-2A

Linear regularization has been applied to the HL-2A infrared imaging bolometer to reconstruct local plasma emission with one-dimensional (1D) and three-dimensional (3D) modeling under the assumption of toroidal symmetry. In the 3D modeling, a new method to calculate the detector point response function is introduced. This method can be adapted to an arbitrarily shaped pinhole. With the full 3D treatment of the detector geometry, up to 50% of the mean-squared error is reduced compared with the 1D modeling. This is attributed to the effects of finite detector size being taken into account in the 3D modeling. Meanwhile, the number of the bolometer pixels has been optimized to 20 × 20 by making a trade-off between the number of bolometer pixels and the sensitivity of the system. The plasma radiated power density distributions have been calculated as a demonstration using 1D modeling and 3D modeling, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tritium Breeding Ratio Evaluation of Solid Breeder Concepts for the FESS-FNSF

This paper presents a parametric study of the Fusion Energy System Studies-Fusion Nuclear Science Facility’s (FNSF’s) tritium breeding performance for several solid breeder concepts, neutron multiplying materials, and blanket materials, assuming volume fractions based on the most recent FNSF design as a realistically representative fusion facility. In this study, we initially surveyed the tritium breeding ratio (TBR) of several solid breeder concepts by employing a simplified but efficient one-dimensional (1-D) infinite cylinder reduced-order model (ROM). Parametric studies were performed with the ROMs for the full range of breeder-to-multiplier ratios to identify the optimum mixture compositions for each breeder type that would lead to a maximum TBR. These optimized breeder-multiplier combinations were then homogenized with FNSF blanket component materials to estimate their impacts on the TBR. Subsequently, as a validation step for the optimal designs, TBR calculations were performed using a more realistic modified 1-D ROM with inner and outer breeding regions, as well as with a fully detailed 22.5-deg three-dimensional (3-D) sector of the FNSF to assess the impact of geometry details on the TBR. The differences between the two 1-D models were negligible, while the ROMs were able to correctly predict trends and identify the maximum and minimum TBR cases, as well as show consistent biases relative to the results produced by the full 3-D, 22.5-deg sector for specific breeder/multiplier combinations. Solid breeder concepts such as Li 2 O, Li 4 SiO 4 , and Li 8 ZrO 6 outperformed all others in this study in terms of TBR performance when combined with all the neutron multiplier materials selected. Here, an underlying goal of this study was to develop and improve rapid and reliable ROMs to aid designers during parametric optimizations of highly complex and computationally expensive fusion models.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Superlattice photonic crystal as broadband solar absorber for high temperature operation

Here, a high performance solar absorber using a 2D tantalum superlattice photonic crystal (PhC) is proposed and its design is optimized for high-temperature energy conversion. In contrast to the simple lattice PhC, which is limited by diffraction in the short wavelength range, the superlattice PhC achieves solar absorption over broadband spectral range due to the contribution from two superposed lattices with different cavity radii. The superlattice PhC geometry is tailored to achieve maximum thermal transfer efficiency for a low concentration system of 250 suns at 1500 K reaching 85.0% solar absorptivity. In the high concentration case of 1000 suns, the superlattice PhC absorber achieves a solar absorptivity of 96.2% and a thermal transfer efficiency of 82.9% at 1500 K, amounting to an improvement of 10% and 5%, respectively, versus the simple square lattice PhC absorber. In addition, the performance of the superlattice PhC absorber is studied in a solar thermophotovoltaic system which is optimized to minimize absorber re-emission by reducing the absorber-to-emitter area ratio and using a highly reflective silver aperture.

14 SOLAR ENERGY↗

The Inelastic Instrument suite at the SNS

Abstract The instruments in the extensive suite of spectrometers at the SNS are in various stages of installation and commissioning. The Back Scattering Spectrometer (BASIS) is installed and is in commissioning. It's near backscattering analyzer crystals provide the 3 eV resolution as expected. BASIS will enter the user program in the fall of 2007. The ARCS wide angular-range thermal to epithermal neutron spectrometer will come on line in the fall of 2007 followed shortly by the Cold Neutron Chopper Spectrometer. These two direct geometry instruments provide moderate resolution and the ability to trade resolution for flux. In addition both instruments have detector coverage out to 140o to provide a large Q range. The SEQUOIA spectrometer, complete in 2008, is the direct geometry instrument that will provide fine resolution in the thermal to epithermal range. The Spin-Echo spectrometer, to be completed on a similar time scale, will provide the finest energy resolution worldwide. The HYSPEC spectrometer, available no later than 2011, will provide polarized capabilities and optimized flux in the thermal energy range. Finally, the Vision chemical spectrometer will use crystal analyzers to study energy transfers into the epithermal range

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct air capture with amino acid solvent: Operational optimization using a crossflow air‐liquid contactor

Direct air capture (DAC) is a negative emission technology for removing CO2 from the atmosphere to maintain the CO 2 level within a reasonable range so as to address greenhouse effects. In this study, the operational optimization of lab-scale DAC has been investigated using a crossflow air-liquid contactor loaded with a three dimensionally printed Gyroid packing structure and a potassium sarcosinate solvent. The effects of various parameters, including feed air flow rate, liquid solvent flow rate, contactor geometry, and ambient temperature, are examined. The results demonstrate that the Gyroid packing design achieves comparable CO 2 capture performance to conventional packed beds but with a significantly lower pressure drop of up to 77.8%, suggesting its potential as an efficient and cost-effective solution for gas–liquid contactors in DAC. Additionally, the study explores the climate impact on CO 2 capture performance and finds that as the air temperature increases from 35 to 95°F at a fixed relative humidity of 80%, the CO 2 capture rate increased from 23.2% to 46.8% with better stability. The research highlights the importance of optimizing contactor design and operational conditions to improve the CO 2 capture rate and feasibility of DAC systems as a negative emission technology for addressing greenhouse effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Drosophila Frataxin: an Iron Chaperone During Cellular [2Fe-2S] Cluster Bioassembly

Frataxin, a mitochondrial protein that is directly involved in regulating cellular iron homeostasis, has been suggested to serve as an iron chaperone during cellular Fe-S cluster biosynthesis. In humans, decreased amounts or impaired function of frataxin causes the autosomal recessive neurodegenerative disorder Friedreich's ataxia. Cellular production of Fe-S clusters is accomplished by the Fe cofactor assembly platform enzymes Isu (eukaryotes) and IscU (prokaryotes). In this report, we have characterized the overall stability and iron binding properties of the Drosophila frataxin homologue (Dfh). Dfh is highly folded with secondary structural elements consistent with the structurally characterized frataxin orthologs. While the melting temperature (TM {approx} 59 C) and chemical stability ([urea]50% {approx} 2.4 M) of Drosophila frataxin, measured using circular dichroism (CD) and fluorescence spectroscopy, closely match values determined for the human ortholog, pure Dfh is more stable against autodegradation than both the human and yeast proteins. The ferrous iron binding affinity (Kd {approx} 6.0 {mu}M) and optimal metal to protein stoichiometry (1:1) for Dfh have been measured using isothermal titration calorimetry (ITC). Under anaerobic conditions with salt present, holo-Dfh is a stable iron-loaded protein monomer. Frataxin prevents reactive oxygen species-induced oxidative damage to DNA when presented with both Fe(II) and H2O2. Ferrous iron bound to Dfh is high-spin and held in a partially symmetric Fe-(O/N)6 coordination environment, as determined by X-ray absorption spectroscopy (XAS). Extended X-ray absorption fine structure (EXAFS) simulations indicate the average Fe-O/N bond length in Dfh is 2.13 Angstroms, consistent with a ligand geometry constructed by water and carboxylate oxygens most likely supplied in part by surface-exposed conserved acidic residues located on helix 1 and strand 1 in the structurally characterized frataxin orthologs. The iron-dependent binding affinity (Kd {approx} 0.21 {mu}M) and optimal holo-Dfh to Isu monomer stoichiometry (1:1) have also been determined using ITC. Finally, frataxin mediates the delivery of Fe(II) to Isu, promoting Fe-S cluster assembly in vitro. The Dfh-assisted assembly of Fe-S clusters occurs with an observed kinetic rate constant (kobs) of 0.096 min-1.

59 BASIC BIOLOGICAL SCIENCES↗

Performance optimization of a bendable parabolic cylinder collimating X-ray mirror for the ALS micro-XAS beamline 10.3.2

The Advanced Light Source (ALS) beamline (BL) 10.3.2 is an apparatus for X-ray microprobe spectroscopy and diffraction experiments, operating in the energy range 2.4–17 keV. The performance of the beamline, namely the spatial and energy resolutions of the measurements, depends significantly on the collimation quality of light incident on the monochromator. In the BL 10.3.2 end-station, the synchrotron source is imaged 1:1 onto a set of roll slits which form a virtual source. The light from this source is collimated in the vertical direction by a bendable parabolic cylinder mirror. Details are presented of the mirror design, which allows for precision assembly, alignment and shaping of the mirror, as well as for extending of the mirror operating lifetime by a factor of ~10. Assembly, mirror optimal shaping and preliminary alignment were performed ex situ in the ALS X-ray Optics Laboratory (XROL). Using an original method for optimal ex situ characterization and setting of bendable X-ray optics developed at the XROL, a root-mean-square (RMS) residual surface slope error of 0.31 µrad with respect to the desired parabola, and an RMS residual height error of less than 3 nm were achieved. Once in place at the beamline, deviations from the designed optical geometry ( e.g. due to the tolerances for setting the distance to the virtual source, the grazing incidence angle, the transverse position) and/or mirror shape ( e.g. due to a heat load deformation) may appear. Due to the errors, on installation the energy spread from the monochromator is typically a few electron-volts. Here, a new technique developed and successfully implemented for at-wavelength ( in situ ) fine optimal tuning of the mirror, enabling us to reduce the collimation-induced energy spread to ~0.05 eV, is described.

43 PARTICLE ACCELERATORS↗

FOILPOLARS (Grassmannian Foil Shape Sweeps for Polar Generation) [SWR-26-095]

FOILPOLARS (Grassmannian Foil Shape Sweeps for Polar Generation): Multifidelity aerodynamic polar data generation for hydrofoil/tidal-turbine airfoil sections. Foilpolars ties together three pieces: *AeroSandbox supplies the baseline airfoil coordinates (UIUC database). *G2Aero parameterizes those shapes on a Grassmannian manifold (Karcher mean + PGA basis) and samples new perturbed shapes around that basis. *XFoil (panel method) and NeuralFoil (neural-network surrogate, shipped with AeroSandbox) each solve the resulting shapes for lift, drag, moment, and pressure at the swept angles of attack, Reynolds numbers, and n_crit values. Design optimization of foil shapes in a computationally efficient way requires polars data across many candidate shapes, not just a handful of baseline foils. However, high-fidelity CFD at that scale is too costly, and naive shape perturbation strays from realistic geometries. FOILPOLARS addresses this by loading baseline airfoils (via AeroSandbox) and mapping them onto a Grassmannian manifold (via G2Aero), computing a Karcher mean and principal geodesic analysis (PGA) basis. New shapes are sampled by perturbing PGA coefficients, keeping them close to the manifold of realistic foils. Each sampled shape is evaluated across a configurable sweep of angle of attack, Reynolds number, and critical amplification factor using two solvers: XFoil (panel method) and NeuralFoil (neural-network surrogate), producing a paired dataset of lift, drag, moment, pressure, convergence, and confidence, indexed alongside each shape's PGA coefficients and shared Grassmannian basis in a single xarray dataset. From this, FOILPOLARS produces convergence summaries and comparison plots per shape, Reynolds number, and n_crit. A command-line interface exposes each pipeline stage independently, supporting data-driven design, optimization, and machine-learning workflows for foils.

Sandhu, Rimple [National Laboratory of the Rockies↗

Nature of size effects in compact models of field effect transistors

Investigations have shown that in the local approximation (for sizes L < 100 μm), AlGaN/GaN high electron mobility transistor (HEMT) structures satisfy to all properties of chaotic systems and can be described in the language of fractal geometry of fractional dimensions. For such objects, values of their electrophysical characteristics depend on the linear sizes of the examined regions, which explain the presence of the so-called size effects—dependences of the electrophysical and instrumental characteristics on the linear sizes of the active elements of semiconductor devices. In the present work, a relationship has been established for the linear model parameters of the equivalent circuit elements of internal transistors with fractal geometry of the heteroepitaxial structure manifested through a dependence of its relative electrophysical characteristics on the linear sizes of the examined surface areas. For the HEMTs, this implies dependences of their relative static (A/mm, mA/V/mm, Ω/mm, etc.) and microwave characteristics (W/mm) on the width d of the sink-source channel and on the number of sections n that leads to a nonlinear dependence of the retrieved parameter values of equivalent circuit elements of linear internal transistor models on n and d. Thus, it has been demonstrated that the size effects in semiconductors determined by the fractal geometry must be taken into account when investigating the properties of semiconductor objects on the levels less than the local approximation limit and designing and manufacturing field effect transistors. In general, the suggested approach allows a complex of problems to be solved on designing, optimizing, and retrieving the parameters of equivalent circuits of linear and nonlinear models of not only field effect transistors but also any arbitrary semiconductor devices with nonlinear instrumental characteristics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An end of service life assessment of PMMA lenses from veteran concentrator photovoltaic systems

The optical performance of poly(methyl methacrylate) lenses from veteran concentrator photovoltaic modules was examined after the end of their service life. Lenses from the Martin-Marietta and Intersol module designs were examined from the 'Solar Village' site near Riyadh, Saudi Arabia, as well as the Phoenix Sky Harbor airport, followed by the Arizona Public Service Solar Test and Research (APS-STaR) center in Tempe, Arizona. The various lens specimens were deployed for 20, 27, and 22 years, respectively. Optical characterizations included lens efficiency (Solar Simulator instrument), material transmittance and haze (of coupons cut from veteran lenses, then measured again after their faceted back surface was polished, and then measured again after the incident front surface was polished), and direct transmittance (as a function of detector's acceptance angle, using the Very Low Angular Beam Spread ('VLABS') instrument). Lens efficiency measurements compared the central region to the entire lens, also using hot and cold mirror measurements to diagnose differences in performance. A series of subsequent characterizations was performed because a decrease in performance of greater than 10% was observed for some of the veteran lenses. The optimal focal distance of the lenses was quantified using the Solar Simulator, and then correlated to lens curvature using a recently developed measurement technique. Surface roughness was examined using atomic force microscopy and scanning electron microscopy. Facet geometry (tip and valley radius) was quantified on cross-sectioned specimens. As a result, molecular weight was compared between the incident and faceted surfaces of the lenses.

14 SOLAR ENERGY↗

The Global Optimization of Pt{sub 13} Cluster Using the First-Principle Molecular Dynamics with the Quenching Technique

The high-temperature first-principle molecular dynamics method used to obtain the low energy configurations of clusters [L. L. Wang and D. D. Johnson, PRB 75, 235405 (2007)] is extended to a considerably large temperature range by combination with the quenching technique. Our results show that there are strong correlations between the possibilities for obtaining the ground-state structure and the temperatures. Larger possibilities can be obtained at relatively low temperatures (as corresponds to the pre-melting temperature range). Details of the structural correlation with the temperature are investigated by taking the Pt{sub 13} cluster as an example, which suggests a quite efficient method to obtain the lowest-energy geometries of metal clusters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

Assess the key physics that underpins high-hydro coupling-efficiency in NDCX-II experiments and high-gain heavy ion direct drive target designs using proven hydro codes like HYDRA

The simulations provided in this milestone have solidified the theoretical underpinning of direct drive targets and also the ability to design experiments on NDCX II that will enhance our understanding of ion-beam hydrodynamic coupling, and thus be relevant to IFE. For the case of the IFE targets, we have studied hydro and implosion efficiency using HYDRA in ID, a starting point towards the goal of polar direct drive in geometry compatible with liquid wall chambers. Recent analysis of direct drive fusion energy targets using heavy ion beams has found high coupling efficiency of ion beam energy into implosion energy. However, to obtain optimal coupling, the ion energy must increase during the pulse in order to penetrate the outflowing ablated material, and deposit the energy close enough to the fuel so that the fuel achieves sufficient implosion velocity. We have computationally explored ID (radial) time dependent models of ion driven direct drive capsule implosions using the Arbitrary Lagrangian-Eulerian (ALE) code HYDRA, to help validate the theoretical analysis done so far, particularly exploring the effects of varying the ion energy and ion current over the course of the pulse. On NDCX II, experiments have been proposed to explore issues of ion penetration of the outflowing plasma over the course of the ion pulse. One possibility is to create a first pulse of ions that heats a planar target, and produces an outflow of material. A second pulse, {approx}10 ns after the first, of higher ion energy (and hence larger projected range) will interact with this outflow before reaching and further heating the target. We have investigated whether the change in range can be tailored to match the evolution of the ablation front. We have carried out simulations using the one-dimensional hydrodynamic code DISH and HYDRA to set parameters for this class of experiments. DISH was upgraded with an ion deposition algorithm, and we have carried out ID (planar) simulations. HYDRA was also used for ID (planar) and 2D (r,z) simulations of potential experiments. We have also explored whether similar physics could be studied using an energy ramp (i.e., a velocity tilt) rather than two separate pulses. We have shown that an optimum occurs in the macropulse duration (with fixed velocity tilt) that maximizes the shock strength. In the area of IFE target design we have continued to explore direct drive targets composed of deuterium-tritium fuel and ablator layers. We have extended our previous target designs at 0.44 MJ drive energy, gain 50, (50 MeV foot, 500 MeV main pulse, Rb ion, which requires a large number of beams due to a high beam space charge constraint) to a power plant scale 3.7 MJ drive energy, gain {approx}150 (220 MeV foot, 2.2 GeV main pulse, Hg ion) that eases requirements on the accelerator. We have studied the effects of two important design choices on ICF target performance. We have shown that increasing the number of foot pulses may reduce the target's in-flight adiabat and consequently improve its compressibility and fusion yield. As in the case of laser drive, the first three shocks are the most important to the target's performance, with additional shocks contributing only marginally to compression and burn. We have also demonstrated that ion range lengthening during the main pulse can further reduce the target adiabat and improve the efficiency with which beam energy is coupled into the target. (Ion range lengthening using two different kinetic energies for the foot and main pulse has previously proven effective in the design of high gain targets).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-J-128: 3D Surface Reconstruction of a Patient Using Epipolar Geometry

Purpose: To obtain a 3D surface data of a patient in a non-invasive way can substantially reduce the effort for the registration of patient in radiation therapy. To achieve this goal, we introduced the multiple view stereo technique, which is known to be used in a 'photo tourism' on the internet. Methods: 70 Images were taken with a digital single-lens reflex camera from different angles and positions. The camera positions and angles were inferred later in the reconstruction step. A sparse 3D reconstruction model was locating by SIFT features, which is robust for rotation and shift variance, in each image. We then found a set of correspondences between pairs of images by computing the fundamental matrix using the eight-point algorithm with RANSAC. After the pair matching, we optimized the parameter including camera positions to minimize the reprojection error by use of bundle adjustment technique (non-linear optimization). As a final step, we performed dense reconstruction and associate a color with each point using the library of PMVS. Results: Surface data were reconstructed well by visual inspection. The human skin is reconstructed well, althogh the reconstruction was time-consuming for direct use in daily clinical practice. Conclusion: 3D reconstruction using multi view stereo geometry is a promising tool for reducing the effort of patient setup. This work was supported by JSPS KAKENHI(25861128)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗