Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Low-speed Aerodynamic Investigations of a Hybrid Wing Body Configuration

Two low-speed static wind tunnel tests and a water tunnel static and dynamic forced-motion test have been conducted on a hybrid wing-body (HWB) twinjet configuration. These tests, in addition to computational fluid dynamics (CFD) analysis, have provided a comprehensive dataset of the low-speed aerodynamic characteristics of this nonproprietary configuration. In addition to force and moment measurements, the tests included surface pressures, flow visualization, and off-body particle image velocimetry measurements. This paper will summarize the results of these tests and highlight the data that is available for code comparison or additional analysis.

Vicroy, Dan D.↗

A model of the effects of heavy ion radiation on human tissue

In heavy ion radiotherapy and space travel humans are exposed to energetic heavy ions (C, Si, Fe and others). This type of irradiation often produces more severe biological effects per unit dose than more common X-rays. A new Monte Carlo model generates a physical space with the complex geometry of human tissue or a cell culture based model of tissue, which is affected by the passage of ionizing radiation. For irradiation, the model relies on a physical code for the ion track structure; for tissues, cellular maps are derived from two- or three-dimensional confocal microscopy images using image segmentation algorithm, which defines cells as pixilated volumes. The model is used to study tissue-specific statistics of direct ion hits and the remote ion action on cells. As an application of the technique, we considered the spatial pattern of apoptotic cells after heavy ion irradiation. The pattern of apoptosis is modeled as a stochastic process, which is defined by the action cross section taken from available experimental data. To characterize the degree of apoptosis, an autocorrelation function that describes the spatial correlation of apoptotic cells is introduced. The values of the autocorrelation function demonstrate the effect of the directionality of the radiation track on the spatial arrangements of inactivated cells in tissue. This effect is intrinsic only to high linear-energy-transfer radiation.

59 BASIC BIOLOGICAL SCIENCES↗

Mesoscale simulations of shock initiation in energetic materials characterized by three-dimensional nanotomography.

Three-dimensional shock simulations of energetic materials have been conducted to improve our understanding of initiation at the mesoscale. Vapor-deposited films of PETN and pressed powders of HNS were characterized with a novel three-dimensional nanotomographic technique. Detailed microstructures were constructed experimentally from a stack of serial electron micrographs obtained by successive milling and imaging in a dual-beam FIB/SEM. These microstructures were digitized and imported into a multidimensional, multimaterial Eulerian shock physics code. The simulations provided insight into the mechanisms of pore collapse in PETN and HNS samples with distinctly different three-dimensional pore morphology and distribution. This modeling effort supports investigations of microscale explosive phenomenology and elucidates mechanisms governing initiation of secondary explosives.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Recovery of atmospheric water vapor total column abundance from imaging spectrometer data around 940 nm - Sensitivity analysis and application to Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) data

Two simple techniques (Continuum Interpolated Band Ratio, CIBR, and Narrow/Wide ratio, N/W) to retrieve path precipitable water from AVIRIS high spectral resolution radiance data using the 940 nm water absorption band are compared. A sensitivity analysis was performed using the radiative transfer code LOWTRAN 7 to determine which one of these two approaches will provide a better estimate over land and water areas. The CIBR proved to be the technique less sensitive to perturbing effects, except for errors in visibility estimate. Both techniques were applied to AVIRIS radiance data acquired over Salton Sea, California. Resulting images confirmed that the use of a constant gray reflectance in the model led to a higher overestimation of the amount of water retrieved for N/W over vegetated areas. Validation was performed through comparison between an independent estimate of water vapor from concurrent Reagan sunphotometer measurements and AVIRIS estimates. Amounts retrieved using the N/W approach match more closely in situ measurements, even after adjusting model parameters for background reflectance, viewing geometry, and type of aerosol at the site.

Carrere, Veronique↗

Photoneutron Production Using an Electron Linear Accelerator for Applications in Neutron Imaging

Photoneutron production is possible using an electron linear accelerator and a target capable of generating photonuclear reactions. A short pulse neutron source can be useful for neutron imaging dynamic experiments. This study is aimed at the feasibility of photoneutron production using a 20 MeV electron linear accelerator and tungsten and depleted uranium targets of various thicknesses. MCNP6 (Monte Carlo N-Particle) code will be used to develop a computational model to estimate total neutron yield, and this will be verified at the Idaho State University’s Accelerator Center. After verification of the neutron yield and energy spectra, an additional MCNP6 model will be developed to analyze the neutron imaging processes. This study will potentially prove it is possible to conduct multi-mode imaging experiments on the anticipated Scorpius electron linear accelerator at the Nevada National Security Sites.

43 PARTICLE ACCELERATORS↗

Computational Particle Dynamic Simulations on Multicore Processors (CPDMu) Final Report Phase I

Statement of Problem - Department of Energy has many legacy codes for simulation of computational particle dynamics and computational fluid dynamics applications that are designed to run on sequential processors and are not easily parallelized. Emerging high-performance computing architectures employ massively parallel multicore architectures (e.g., graphics processing units) to increase throughput. Parallelization of legacy simulation codes is a high priority, to achieve compatibility, efficiency, accuracy, and extensibility. General Statement of Solution - A legacy simulation application designed for implementation on mainly-sequential processors has been represented as a graph G. Mathematical transformations, applied to G, produce a graph representation {und G} for a high-performance architecture. Key computational and data movement kernels of the application were analyzed/optimized for parallel execution using the mapping G {yields} {und G}, which can be performed semi-automatically. This approach is widely applicable to many types of high-performance computing systems, such as graphics processing units or clusters comprised of nodes that contain one or more such units. Phase I Accomplishments - Phase I research decomposed/profiled computational particle dynamics simulation code for rocket fuel combustion into low and high computational cost regions (respectively, mainly sequential and mainly parallel kernels), with analysis of space and time complexity. Using the research team's expertise in algorithm-to-architecture mappings, the high-cost kernels were transformed, parallelized, and implemented on Nvidia Fermi GPUs. Measured speedups (GPU with respect to single-core CPU) were approximately 20-32X for realistic model parameters, without final optimization. Error analysis showed no loss of computational accuracy. Commercial Applications and Other Benefits - The proposed research will constitute a breakthrough in solution of problems related to efficient parallel computation of particle and fluid dynamics simulations. These problems occur throughout DOE, military and commercial sectors: the potential payoff is high. We plan to license or sell the solution to contractors for military and domestic applications such as disaster simulation (aerodynamic and hydrodynamic), Government agencies (hydrological and environmental simulations), and medical applications (e.g., in tomographic image reconstruction). Keywords - High-performance Computing, Graphic Processing Unit, Fluid/Particle Simulation. Summary for Members of Congress - Department of Energy has many simulation codes that must compute faster, to be effective. The Phase I research parallelized particle/fluid simulations for rocket combustion, for high-performance computing systems.

97 MATHEMATICS AND COMPUTING↗

Direct Modeling of Scintillator Thickness for Optimal Light Output and Spatial Resolution

It is common in x-ray radiography to use scintillators (e.g., BGO or LSO) to convert x-rays to visible light, which is then recorded by an imaging system. The response of the scintillator depends fundamentally on its thickness, with respect to both its visible light emittance and its spatial resolution. This is important for optimizing light output, signal to noise ratio, or optical response time. Given that it is often cost-prohibitive to procure a variety of scintillator samples and empirically test the performance, it is essential to be able to model and accurately simulate the performance of a scintillator with respect to thickness and other properties, and a direct way of doing this is using Monte Carlo-based radiation transport codes. Such simulations can be expensive in terms of computational time, and the codes are not easily obtained. In this work we first show such simulations, and demonstrate that there is a natural trade-off between light output of a scintillator and its spatial resolution. We then derive a first-principles model that accurately approximates the light output, using straightforward calculations that can be performed quickly with any basic computing software. We compare the results to those obtained from Monte Carlo simulations and show that our simplified model can be used to analyze the tradeoff between emittance and resolution nearly as well as using a full-scale radiation transport code.

Monte Carlo methods, X-ray imaging, scintillation ↗

A flare observed in coronal, transition region, and helium I 10830 Å emissions

On 2012 June 17, we observed the evolution of a C-class flare associated with the eruption of a filament near a large sunspot in the active region NOAA 11504. We obtained high spatial resolution filtergrams using the 1.6 m New Solar Telescope at the Big Bear Solar Observatory in broadband TiO at 706 nm (bandpass: 10 Å) and He I 10830 Å narrow band (bandpass: 0.5 Å, centered 0.25 Å to the blue). We analyze the spatio-temporal behavior of the He I 10830 Å data, which were obtained over a 90''×90'' field of view with a cadence of 10 s. We also analyze simultaneous data from the Atmospheric Imaging Assembly and Extreme Ultraviolet Variability Experiment instruments on board the Solar Dynamics Observatory spacecraft, and data from the Reuven Ramaty High Energy Solar Spectroscopic Imager and GOES spacecrafts. Non-thermal effects are ignored in this analysis. Several quantitative aspects of the data, as well as models derived using the '0D' enthalpy-based thermal evolution of loops model code, indicate that the triplet states of the 10830 Å multiplet are populated by photoionization of chromospheric plasma followed by radiative recombination. Surprisingly, the He II 304 Å line is reasonably well matched by standard emission measure calculations, along with the C IV emission which dominates the Atmosphere Imaging Assembly 1600 Å channel during flares. This work lends support to some of our previous work combining X-ray, EUV, and UV data of flares to build models of energy transport from corona to chromosphere.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-209: Quantification of Image-Guidance Benefit in Image-Guided Radiotherapy of Cancers

Purpose: Image-guidance has been widely used in radiation oncology for accurate radiotherapy. The goal of this study is to quantify the benefit of image-guidance in image-guided radiotherapy (IGRT) of cancers. Methods: In this study, a new index termed image-guidance benefit (IGB), was proposed to quantify the benefit of image-guidance in cancer radiotherapy. It is calculated as a ratio of the square sum of dose differences between planning dose matrix and actual delivery dose matrix post image-guidance to the square sum of dose summation between the two matrixes, summing over all dose scoring voxels. Ranging from 0 to 1, larger IGB values indicate larger benefit out of image-guidance. With IRB approval, the DICOM RT files and 3D couch shifts applied during IGRT of 2219 patients were collected, based on which patient-specific IGB values were calculated with an in-house MATLAB code. Results: In this study, the mean IGB value was found to be 0.0398 (0.000583–0.999) with a positive correlation between IGB value and 3D couch shift vector at 0.0435 per cm (P<0.0001). With 2 mm shift as a threshold above which an image-guidance is deemed clinically necessary, the corresponding mean IGB value was 0.00457, much less than 0.0398 (P<0.001). However, the IGB values of 56 cases based on couch shifts were less than those based on 2 mm shift. Conclusion: The IGB values were patient-specific and site-dependent. Using 2 mm shifts as criterion for applying image-guidance, the applied image-guidance procedures were found clinically necessary and highly beneficial in 97.5% of cancer patients. However, image-guidance procedures were found over-used in about 2.5% of cancer patients in our current practices of IGRT, which should be avoided as they added no benefit in improving delivery accuracy while increasing cancer risk.

60 APPLIED LIFE SCIENCES↗

Neutron Imaging at LANSCE—From Cold to Ultrafast

In recent years, neutron radiography and tomography have been applied at different beam lines at Los Alamos Neutron Science Center (LANSCE), covering a very wide neutron energy range. The field of energy-resolved neutron imaging with epi-thermal neutrons, utilizing neutron absorption resonances for contrast as well as quantitative density measurements, was pioneered at the Target 1 (Lujan center), Flight Path 5 beam line and continues to be refined. Applications include: imaging of metallic and ceramic nuclear fuels, fission gas measurements, tomography of fossils and studies of dopants in scintillators. The technique provides the ability to characterize materials opaque to thermal neutrons and to utilize neutron resonance analysis codes to quantify isotopes to within 0.1 atom %. The latter also allows measuring fuel enrichment levels or the pressure of fission gas remotely. More recently, the cold neutron spectrum at the ASTERIX beam line, also located at Target 1, was used to demonstrate phase contrast imaging with pulsed neutrons. This extends the capabilities for imaging of thin and transparent materials at LANSCE. In contrast, high-energy neutron imaging at LANSCE, using unmoderated fast spallation neutrons from Target 4 [Weapons Neutron Research (WNR) facility] has been developed for applications in imaging of dense, thick objects. Using fast (ns), time-of-flight imaging, enables testing and developing imaging at specific, selected MeV neutron energies. The 4FP-60R beam line has been reconfigured with increased shielding and new, larger collimation dedicated to fast neutron imaging. The exploration of ways in which pulsed neutron beams and the time-of-flight method can provide additional benefits is continuing. We will describe the facilities and instruments, present application examples and recent results of all these efforts at LANSCE.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Resonance Imaging-Based Radiation-Absorbed Dose Estimation of {sup 166}Ho Microspheres in Liver Radioembolization

Purpose: To investigate the potential of magnetic resonance imaging (MRI) for accurate assessment of the three-dimensional {sup 166}Ho activity distribution to estimate radiation-absorbed dose distributions in {sup 166}Ho-loaded poly (L-lactic acid) microsphere ({sup 166}Ho-PLLA-MS) liver radioembolization. Methods and Materials: MRI, computed tomography (CT), and single photon emission CT (SPECT) experiments were conducted on an anthropomorphic gel phantom with tumor-simulating gel samples and on an excised human tumor-bearing liver, both containing known amounts of {sup 166}Ho-PLLA-MS. Three-dimensional radiation-absorbed dose distributions were estimated at the voxel level by convolving the {sup 166}Ho activity distribution, derived from quantitative MRI data, with a {sup 166}Ho dose point-kernel generated by MCNP (Monte Carlo N-Particle transport code) and from Medical Internal Radiation Dose Pamphlet 17. MRI-based radiation-absorbed dose distributions were qualitatively compared with CT and autoradiography images and quantitatively compared with SPECT-based dose distributions. Both MRI- and SPECT-based activity estimations were validated against dose calibrator measurements. Results: Evaluation on an anthropomorphic phantom showed that MRI enables accurate assessment of local {sup 166}Ho-PLLA-MS mass and activity distributions, as supported by a regression coefficient of 1.05 and a correlation coefficient of 0.99, relating local MRI-based mass and activity calculations to reference values obtained with a dose calibrator. Estimated MRI-based radiation-absorbed dose distributions of {sup 166}Ho-PLLA-MS in an ex vivo human liver visually showed high correspondence to SPECT-based radiation-absorbed dose distributions. Quantitative analysis revealed that the differences in local and total amounts of {sup 166}Ho-PLLA-MS estimated by MRI, SPECT, and the dose calibrator were within 10%. Excellent agreement was observed between MRI- and SPECT-based dose-volume histograms. Conclusions: Quantitative MRI was demonstrated to provide accurate three-dimensional {sup 166}Ho-PLLA-MS activity distributions, enabling localized intrahepatic radiation-absorbed dose estimation by convolution with a {sup 166}Ho dose point-kernel for liver radioembolization treatment optimization and evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

To stack or not to stack: Spectral energy distribution properties of Lyα-emitting galaxies at z = 2.1

We use the Cosmic Assembly Near-Infrared Deep Extragalactic Legacy Survey (CANDELS) GOODS-S multi-wavelength catalog to identify counterparts for 20 Lyα emitting (LAE) galaxies at z = 2.1. We build several types of stacked spectral energy distributions (SEDs) of these objects. We combine photometry to form average and median flux-stacked SEDs, and postage-stamp images to form average and median image-stacked SEDs. We also introduce scaled flux stacks that eliminate the influence of variation in overall brightness. We use the SED fitting code SpeedyMC to constrain the physical properties of individual objects and stacks. Our LAEs at z = 2.1 have stellar masses ranging from 2 × 10{sup 7} M {sub ☉} to 8 × 10{sup 9} M {sub ☉} (median = 3 × 10{sup 8} M {sub ☉}), ages ranging from 4 Myr to 500 Myr (median = 100 Myr), and E(B – V) between 0.02 and 0.24 (median = 0.12). Although still low, this represents significantly more dust reddening than has been reported for LAEs at higher redshifts. We do not observe strong correlations between Lyα equivalent width (EW) and age or E(B – V). The Lyα radiative transfer (q) factors of our sample are predominantly close to one and do not correlate strongly with EW or E(B – V). The absence of strong correlations with EW or q implies that Lyα radiative transfer is highly anisotropic and/or prevents Lyα photons from scattering in dusty regions. The SED parameters of the flux stacks match the average and median values of the individual objects, with the flux-scaled median SED performing best with uncertainties reduced by a factor of two. Median image-stacked SEDs provide a poor representation of the median individual object, and none of the stacking methods capture the large dispersion of LAE properties.

79 ASTRONOMY AND ASTROPHYSICS↗

2D imaging of helium ion velocity in the DIII-D divertor

Two-dimensional imaging of parallel ion velocities are compared to fluid modeling simulations to understand the role of ions in determining divertor conditions and benchmark the UEDGE fluid modeling code. Pure helium discharges are used so that spectroscopic He+measurements represent the main-ion population at small electron temperatures. Electron temperatures and densities in the divertor match simulated values to within about 20-30% establishing the experiment/model match as being at least as good as those normally obtained in the more regularly simulated deuterium plasmas. He + brightness (HeII) comparison indicates that the degree of detachment is captured well by UEDGE, principally due to the inclusion of E x B drifts. Tomographically inverted Coherence Imaging Spectroscopy (CIS) measurements are used to determine the He + parallel velocities which display excellent agreement between model and experiment near the divertor target where He + is predicted to be the main-ion species and where electron-dominated physics dictates the parallel momentum balance. Upstream near the X-point where He + is a minority species and ion-dominated physics plays a more important role, there is an underestimation of the flow velocity magnitude by a factor of 2-3. These results indicate that more effort is required to be able to correctly predict ion momentum in these challenging regimes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Conditional replenishment using motion prediction

Conditional replenishment is an interframe video compression method that uses correlation in time to reduce video transmission rates. This method works by detecting and sending only the changing portions of the image and by having the receiver use the video data from the previous frame for the non-changing portion. The amount of compression that can be achieved through this technique depends to a large extent on the rate of change within the image, and can vary from 10 to 1 to less than 2 to 1. An additional 3 to 1 reduction in rate is obtained by the intraframe coding of data blocks using a 2-dimensional variable rate Hadamard transform coder. A further additional 2 to 1 rate reduction is achieved by using motion prediction. Motion prediction works by measuring the relative displacements of a subpicture from one frame to the next. The subpicture can then be transmitted by sending only the value of the 2-dimensional displacement. Computer simulations have demonstrated that data rates of 2 to 4 Mega-bits/second can be achieved while still retaining good fidelity in the image.

Hein, D. N.↗

An image based information system - Architecture for correlating satellite and topological data bases

The paper describes the development of an image based information system and its use to process a Landsat thematic map showing land use or land cover in conjunction with a census tract polygon file to produce a tabulation of land use acreages per census tract. The system permits the efficient cross-tabulation of two or more geo-coded data sets, thereby setting the stage for the practical implementation of models of diffusion processes or cellular transformation. Characteristics of geographic information systems are considered, and functional requirements, such as data management, geocoding, image data management, and data analysis are discussed. The system is described, and the potentialities of its use are examined.

Bryant, N. A.↗

Applying compressive sensing to TEM video: A substantial frame rate increase on any camera

One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integrated into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.

36 MATERIALS SCIENCE↗

Test of 3D CT reconstructions by EM + TV algorithm from undersampled data

Computerized tomography (CT) plays an important role in medical imaging for diagnosis and therapy. However, CT imaging is connected with ionization radiation exposure of patients. Therefore, the dose reduction is an essential issue in CT. In 2011, the Expectation Maximization and Total Variation Based Model for CT Reconstruction (EM+TV) was proposed. This method can reconstruct a better image using less CT projections in comparison with the usual filtered back projection (FBP) technique. Thus, it could significantly reduce the overall dose of radiation in CT. This work reports the results of an independent numerical simulation for cone beam CT geometry with alternative virtual phantoms. As in the original report, the 3D CT images of 128 Multiplication-Sign 128 Multiplication-Sign 128 virtual phantoms were reconstructed. It was not possible to implement phantoms with lager dimensions because of the slowness of code execution even by the CORE i7 CPU.

61 RADIATION PROTECTION AND DOSIMETRY↗

4D-CT scans reveal reduced magnitude of respiratory liver motion achieved by different abdominal compression plate positions in patients with intrahepatic tumors undergoing helical tomotherapy

Purpose: While abdominal compression (AC) can be used to reduce respiratory liver motion in patients receiving helical tomotherapy for hepatocellular carcinoma, the nature and extent of this effect is not well described. The purpose of this study was to evaluate the changes in magnitude of three-dimensional liver motion with abdominal compression using four-dimensional (4D) computed tomography (CT) images of several plate positions. Methods: From January 2012 to October 2015, 72 patients with intrahepatic carcinoma and divided into four groups underwent 4D-CT scans to assess respiratory liver motion. Of the 72 patients, 19 underwent abdominal compression of the cephalic area between the subxiphoid and umbilicus (group A), 16 underwent abdominal compression of the caudal region between the subxiphoid area and the umbilicus (group B), 11 patients underwent abdominal compression of the caudal umbilicus (group C), and 26 patients remained free breathing (group D). 4D-CT images were sorted into ten-image series, according to the respiratory phase from the end inspiration to the end expiration, and then transferred to treatment planning software. All liver contours were drawn by a single physician and confirmed by a second physician. Liver relative coordinates were automatically generated to calculate the liver respiratory motion in different axial directions to compile the 10 ten contours into a single composite image. Differences in respiratory liver motion were assessed with a one-way analysis of variance test of significance. Results: The average respiratory liver motion in the Y axial direction was 4.53 ± 1.16, 7.56 ± 1.30, 9.95 ± 2.32, and 9.53 ± 2.62 mm in groups A, B, C, and D, respectively, with a significant change among the four groups (p < 0.001). Abdominal compression was most effective in group A (compression plate on the subxiphoid area), with liver displacement being 2.53 ± 0.93, 4.53 ± 1.16, and 2.14 ± 0.92 mm on the X-, Y-, and Z-axes, respectively. There was no significant difference in respiratory liver motion between group C (displacement: 3.23 ± 1.47, 9.95 ± 2.32, and 2.92 ± 1.10 mm on the X-, Y-, and Z-axes, respectively) and group D (displacement: 3.35 ± 1.55, 9.53 ± 2.62, and 3.35 ± 1.73 mm on the X-, Y-, and Z-axes, respectively). Abdominal compression was least effective in group C (compression on caudal umbilicus), with liver motion in this group similar to that of free-breathing patients (group D). Conclusions: 4D-CT scans revealed significant liver motion control via abdominal compression of the subxiphoid area; however, this control of liver motion was not observed with compression of the caudal umbilicus. The authors, therefore, recommend compression of the subxiphoid area in patients undergoing external radiotherapy for intrahepatic carcinoma.

60 APPLIED LIFE SCIENCES↗