At least 1,711 records · Page 95

Device Voltage Stress from Ground Leakage Current in Medium-Voltage Solid-State Transformer

Grounding related issues are critical for safe and reliable operation of solid-state transformer (SST) in medium-voltage (MV) applications, e.g., solar photovoltaic and energy storage integration, date center, electric vehicle fast charging, etc. This article presents for the first time the issue of additional device voltage stress due to grounding-loop current in current-source SST, using the soft-switching solid-state transformer (S4T) as an example. The S4T features single-stage isolated AC-AC, AC-DC, or DC-DC conversion with full-range ZVS, derived from flyback converter or current-source converter (CSC). However, the flyback operation for CSC-based SST means that magnetizing current flows through the reverse-blocking devices on only one side of the medium-frequency transformer (MFT) at a time. Then, the voltages across the devices, especially those on the other side of the MFT, can be influenced by parasitic current. A parasitic model of a modular S4T (M-S4T) prototype is developed from direct measurements and datasheets. Using the developed parasitic model and equivalent circuits, the causes of the voltage stress are analyzed. A voltage-stress mitigation scheme of connecting additional grounding capacitors is proposed. Damping resistors are also installed to damp out the grounding-loop resonance. A robust parameter design of the proposed scheme is given. The existence of the voltage stress issue and the effectiveness of the proposed scheme are verified experimentally on an MV SiC M-S4T prototype with inherent parameter variations among the five modules in the prototype. Here, both single-module and stacked-module operation are demonstrated during steady state and dynamic conditions up to 4 kV peak.

42 ENGINEERING↗

Carrier Dynamics of Polar, Semipolar, and Nonpolar InGaN/GaN LEDs Measured by Small-Signal Electroluminescence

The carrier dynamics in InGaN/GaN light-emitting diodes (LEDs) are directly tied to their efficiency and maximum modulation speed, which are important metrics for solid-state lighting, displays, and optical communication. In this work, we measure the carrier dynamics of a variety of InGaN/GaN LEDs using small-signal electroluminescence methods [1]. A rate equation approach and associated small-signal circuit are used to model carrier injection, recombination in the active region, recombination in the cladding regions, and carrier escape. The model is fit to the measured optical frequency response (S21) and input impedance (S11) of the LEDs to extract the various carrier lifetimes, the carrier density, and the radiative and non-radiative recombination rates. We specifically study planar nonpolar and semipolar LEDs, which show record-high modulation speeds for III-nitride LEDs and present the modulation characteristics of core-shell nanowire-based LEDs. The planar nonpolar m-plane ($101\bar{0}$) micro-LEDs achieve a record-high -3dB modulation bandwidth for a III-nitride LED of 1.5 GHz [2]. The -3dB response of an electrically injected nanowire-based micro-LED with nonpolar facets is also reported, showing a -3dB bandwidth of 1.2 GHz [3]. The high speed is attributed to the shorter carrier lifetime associated with the nonpolar orientation. We also study the carrier dynamics in semipolar ($20\bar{2}\bar{1}$) LEDs for various temperatures [4]. Finally, we present carrier dynamics measurements on commercial-grade c-plane epitaxy for various active region designs, including a wavelength series and a growth quality series. The wavelength series offers insight into the contributions of the quantum confined Stark effect (QCSE) and InGaN material quality on the green gap [5]. The growth quality series investigates the role of non-radiative centers on the LED performance. Extraction of the carrier dynamics using small-signal electroluminescence offers insight into the factors limiting the efficiency and high-speed performance of III-nitride emitters and can be leveraged to ultimately improve the devices.

LEDs, InGaN, electroluminescence, bandwidth, modul↗

Dynamics of A Vibration Isolation System Including Inertia of the Human Body

Using an exercise device in a spacecraft is liable to transmit an unacceptable amount of vibration to that vehicle. This is commonly mitigated by a Vibration Isolation System (VIS), whose dynamics must be analyzed to confirm that the oscillatory forces on the spacecraft remain within allowed range, both from a structural and microgravity perspective (see, e.g., [1]). When modeling a VIS for countermeasures devices, one common approach is to record forces and moments applied on the floor while exercising, and then drive the VIS simulation by applying these recorded loads to the exercise platform part of the VIS mechanical model. This approach misses the fact that when exercising on a moving platform, the force and moment on it will differ from that on the stationary floor due to inertial effects involving the human body. For example, standing up on a platform as it gives under the subject’s feet reduces the foot force on it, and such inertial effects are especially complex for rotational motion. In principle, one could model both the motion of the human body and dynamics of the VIS mechanism in a single combined simulation, e.g., employing a tool such as the commonly used biomechanical simulation OpenSim. Here, the joints of the human body would be driven kinematically along prescribed exercise trajectories while the dynamics engine computed the response of the VIS degrees of freedom. However, mechanism designers and biomechanics experts have their own established tools, making it very desirable to have a way of decoupling the biomechanics from the VIS modeling, simulation, and analyses. We have derived a set of equations that rigorously accomplishes this goal, and have implemented them as an interface function that provides an alternative driving mechanism for an existing force-based VIS analysis simulation. When enabled, the simulated human/VIS system dynamics is now driven by this function, instead of the recorded force methodology described above. The function is designed to accept input from a data file containing the required time-stamped human motion and inertia terms corresponding to the specific exercise in question. This data file is generated by an OpenSim plugin written for that purpose. The existing VIS analytical simulation is developed using NASA’s Trick Simulation Environment [2], as well as its MBDyn multibody dynamics [3] package. The presentation will provide a detailed overview of the mathematical formulation, assumptions, plugin implementation, software interfaces, and results for a sample set of representative exercises. The results from this work aim to better inform VIS design efforts, as well as countermeasure device/protocol designs with respect to exercise type and frequency effects on vehicle structural and microgravity restrictions.

Countermeasures↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗

Artificial Intelligence Medical Support for Long-Duration Space Missions

We envision an artificial intelligence (AI) based system that will provide support and recommendations to the crew medical officer (CMO) and ground flight surgeon during long-duration space missions. Such a system would be pretrained on the knowledgebase of clinical knowledge on Earth, minimizing the amount of Earth data that needs to be transferred into space. Then during deployment, the system would be constantly refined through active learning from diverse streams of data from sensors in the spacecraft, data collected daily from individual astronauts, and human-in-the-loop feedback from the crew. The model could be interrogated for predictions and recommendations on personalized crew health based on the overall status of the spacecraft, medicinal stores, and status of other crew members. Adaptation techniques would be used to incorporate spaceflight data that have very different distributions from the training data due to the extreme environment. Edge computing and the most advanced neuromorphic processing would enable computation in scenarios with low power and bandwidth, while dimensionality reduction would be employed to ensure that the input data streams from spaceflight are as small as possible. In order to realize this long-term vision, several hardware and software aspects need to be developed and assembled. First, models pretrained on Earth biomedical data would need to be evaluated for predictive accuracy, and the best one selected. That model would need to be adapted to learn from diverse, sparse, and inconsistently measured data streams, as well as human-in-the-loop feedback. A data integration, standardization, and dimensionality reduction methodology would need to be developed to handle all data types and feed them into the model. Once the software and data infrastructure is developed, it would need to be integrated with small footprint compute processors and tested in high-radiation, high-vibration, unregulated temperature situations. As a short-term goal, we recommend to focus on the development of the data and model software structure. Several large language models (LLM) already exist that have been trained on Earth biomedical and clinical knowledgebases, including BioMedLLM, Med-PaLM, SPOKE LLM, and Foresight. These models need to be evaluated for accuracy and the best one chosen for a proof-of-concept structure, while maintaining awareness of the accelerating AI field and incorporating any newly improved model architectures as needed. Then, we recommend to develop a database of synthetic data types to mimic the diverse data streams that are expected in a long-duration space mission. This should include environmental and microbial data from the spacecraft, non-invasive data from wearables and point-of-care devices employed by astronauts, and more invasive molecular and physiological monitoring of clinical and biomarker data from astronauts. The data standardization methodology should be developed, and these data streams used to refine the clinical LLM. Several scenarios should be developed that could plausibly come up in a long-duration space mission, and changes or aberrations introduced to the data at specific times to mimic these scenarios. Then, question and answer tasks should be designed to interrogate the model for predictions and recommendations, with acceptable answers already identified.

Artificial Intelligence↗

Improving Realism in Reduced Gravity Simulators

Since man was first determined to walk on the moon, simulating the lunar environment became a priority. Providing an accurate reduced gravity environment is crucial for astronaut training and hardware testing. This presentation will follow the development of reduced gravity simulators to a final comparison of environments between the currently used systems. During the Apollo program era, multiple systems were built and tested, with several NASA centers having their own unique device. These systems ranged from marionette-like suspension devices where the subject laid on his side, to pneumatically driven offloading harnesses, to parabolic flights. However, only token comparisons, if any, were made between systems. Parabolic flight allows the entire body to fall at the same rate, giving an excellent simulation of reduced gravity as far as the biomechanics and physical perceptions are concerned. While the effects are accurate, there is limited workspace, limited time, and high cost associated with these tests. With all mechanical offload systems only the parts of the body that are actively offloaded feel any reduced gravity effects. The rest of the body still feels the full effect of gravity. The Partial Gravity System (Pogo) is the current ground-based offload system used to training and testing at the NASA Johnson Space Center. The Pogo is a pneumatic type system that allows for offloaded motion in the z-axis and free movement in the x-axis, but has limited motion in the y-axis. The pneumatic system itself is limited by cylinder stroke length and response time. The Active Response Gravity Offload System (ARGOS) is a next generation groundbased offload system, currently in development, that is based on modern robotic manufacturing lines. This system is projected to provide more z-axis travel and full freedom in both the x and y-axes. Current characterization tests are underway to determine how the ground-based offloading systems perform, how they compare to parabolic flights, and which of the systems is preferable for specific uses. These tests were conducted with six degree of freedom robots and manual inputs. Initial results show a definitive difference in abilities of the two offload systems.

Cowley, Matthew↗

SiC-Based 5-kV Universal Modular Soft-Switching Solid-State Transformer (M-S4T) for Medium-Voltage DC Microgrids and Distribution Grids

Medium-voltage DC (MVDC) grids are attractive for electric aircraft and ship power systems, battery energy storage system (BESS), fast charging electric vehicle (EV), etc. Such EV or BESS applications need isolated bidirectional MVDC to LVDC or LVAC converters. However, the existing Si-based solutions cannot fulfill the requirements of a high-efficiency and robust converter for MVDC grids. This paper presents a 5 kV SiC-based universal modular solid-state transformer (SST). This universal current-source SST can interface either a LVAC or LVDC grid with a MVDC grid in single-stage power conversion, while the conventional dual active bridge (DAB) converter needs an additional inverter. The proposed SST module using 3.3 kV SiC MOSFETs and diodes is bidirectional and can serve as a building block in series or parallel for higher-voltage higher-power systems. The topology of each module is based on the soft-switching solid-state transformer (S4T) with reduced conduction loss, which features reduced EMI through controlled dv/dt, and high efficiency with full-range ZVS for main devices and ZCS for auxiliary devices. Operation principle of the modular S4T (M-S4T), capacitor voltage balancing control between the cascaded modules, design of components including a medium-voltage (MV) medium-frequency transformer (MFT) to realize a 50 kVA 5 kV DC to 600 V DC or 480 V AC M-S4T are presented. Importantly, the MV MFT prototype achieves very low leakage inductance (0.13%) and 15 kV insulation with coaxial cables and nanocrystalline cores. Here, the proposed universal modular SST is compared against the DAB solution and verified with DC-DC and DC-AC simulation and 4 kV experimental results. Significantly, the MV experimental results of a modular DC transformer with each module at MVDC are rarely covered in the literature and reported for the first time.

14 SOLAR ENERGY↗

Gross-fragmentation of meteoroids and bulk density of Geminids from photographic fireball records

The explicit solution of the drag and ablation equations of a single nonfragmenting meteoroid moving in any actual atmosphere was published several years ago. The solution yields the theoretical relation of l, the distance flown by the meteoroid in its trajectory, as a function of time, t, assuming that the height, h, is a known function of l. The photographic records of meteors and fireballs are coded by time marks, using a rotating shutter or a similar device to break the moving image. Time is, thus, the independent variable and for each time mark on a meteoroid trajector, the observed distance along the trajectory, l sub obs, as well as the double- or multiple- station photographs of the same meteoroid. Applying this solution to all available Prairie Network (PN) fireball-records, we recognized that the majority of them gave good solutions with standard deviations somewhat bigger than the intrinsic geometrical precision of the data. We also noticed that, on an average, previous methods of evaluation of the meteoroid velocities (interpolation polynomials, numerical differenciation of the observed l sub obs) used up to only several tens of percent of the intrinsic precision of the PN observational data. When residuals of these solutions, i.e. l sub obs - l sub com, were represented as a function of time for about 75 percent of solutions. The remaining 25 percent of residuals showed systematic changes with time exceeding one standard deviation. We tried to explain these systematic time course of residuals by using different meteoroids first computed theoretically and then analyzed by the same model as the natural PN fireballs were. The conclusion of these model computations is that systematic time changes of residuals in the nonfragmenting model exceeding one standard of deviation are caused by sudden gross fragmentation at one or more trajectory points. Thus, we generalized the explicit solution of the drag and ablation equations of a single nonfragmenting meteoroid by allowing for one or more points, where sudden gross fragmentation can occur. Using this generalized solution, the distances along the meteoroid trajectory can be computed for any choice of input parameters and compared with the observed distances flown by the meteoroid. For the most precise and long fireball trajectories, the least-squares solution can, thus, yield the initial velocities, the ablation coefficients, the dynamical masses, the positions of gross-fragmentation points, and the terminal mass. At a gross-fragmentation point, the ratio of the main mass to all the remaining fragments can be compared with the dynamic mass determined from our gross-fragmentation model and, thus, the meteoroid bulk density can be evaluated. We applied the gross-fragmentation model to sever PN fireballs showing time changes of residuals, and we recognized that, in all these cases, the new computed bulk densities of meteoroids resulted higher in comparison with the meteoroid densities determined with the non-gross-fragmentation model. Other aspects of the study are discussed.

Ceplecha, Zdenek↗

Discovery of stationary operation of quiescent H-mode plasmas with net-zero neutral beam injection torque and high energy confinement on DIII-D

Recent experiments in DIII-D [J. L. Luxon et al., in Plasma Physics and Controlled Nuclear Fusion Research 1996 (International Atomic Energy Agency, Vienna, 1987), Vol. I, p. 159] have led to the discovery of a means of modifying edge turbulence to achieve stationary, high confinement operation without Edge Localized Mode (ELM) instabilities and with no net external torque input. Eliminating the ELM-induced heat bursts and controlling plasma stability at low rotation represent two of the great challenges for fusion energy. By exploiting edge turbulence in a novel manner, we achieved excellent tokamak performance, well above the H{sub 98y2} international tokamak energy confinement scaling (H{sub 98y2} = 1.25), thus meeting an additional confinement challenge that is usually difficult at low torque. The new regime is triggered in double null plasmas by ramping the injected torque to zero and then maintaining it there. This lowers E × B rotation shear in the plasma edge, allowing low-k, broadband, electromagnetic turbulence to increase. In the H-mode edge, a narrow transport barrier usually grows until MHD instability (a peeling ballooning mode) leads to the ELM heat burst. However, the increased turbulence reduces the pressure gradient, allowing the development of a broader and thus higher transport barrier. A 60% increase in pedestal pressure and 40% increase in energy confinement result. An increase in the E × B shearing rate inside of the edge pedestal is a key factor in the confinement increase. Strong double-null plasma shaping raises the threshold for the ELM instability, allowing the plasma to reach a transport-limited state near but below the explosive ELM stability boundary. The resulting plasmas have burning-plasma-relevant β{sub N} = 1.6–1.8 and run without the need for extra torque from 3D magnetic fields. To date, stationary conditions have been produced for 2 s or 12 energy confinement times, limited only by external hardware constraints. Stationary operation with improved pedestal conditions is highly significant for future burning plasma devices, since operation without ELMs at low rotation and good confinement is key for fusion energy production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crew Exploration Vehicle (CEV) (Orion) Occupant Protection

The purpose of this study was to determine the similarity between the response of the THUMS model and the Hybrid III Anthropometric Test Device (ATD) given existing Wright-Patterson (WP) sled tests. There were four tests selected for this comparison with frontal, spinal, rear, and lateral loading. The THUMS was placed in a sled configuration that replicated the WP configuration and the recorded seat acceleration for each test was applied to model seat. Once the modeling simulations were complete, they were compared to the WP results using two methods. The first was a visual inspection of the sled test videos compared to the THUMS d3plot files. This comparison resulted in an assessment of the overall kinematics of the two results. The other comparison was a comparison of the plotted data recorded for both tests. The metrics selected for comparison were seat acceleration, belt forces, head acceleration and chest acceleration. These metrics were recorded in all WP tests and were outputs of the THUMS model. Once the comparison of the THUMS to the WP tests was complete, the THUMS model output was also examined for possible injuries in these scenarios. These outputs included metrics for injury risk to the head, neck, thorax, lumbar spine and lower extremities. The metrics to evaluate head response were peak head acceleration, HIC15, and HIC36. For the neck, N (sub ij) was calculated. The thorax response was evaluated with peak chest acceleration, the Combined Thoracic Index (CTI), sternal deflection, chest deflection, and chest acceleration- 3 ms clip. The lumbar spine response was evaluated with lumbar spine force. Finally the lower extremity response was evaluated by femur and tibia force. The results of the simulation comparisons indicate the THUMS model had a similar response to the Hybrid III dummy given the same input. The primary difference seen between the two was a more flexible response of the THUMS compared to the Hybrid III. This flexibility was most pronounced in the neck flexion, shoulder deflection and chest deflection. Due to the flexibility of the THUMS, the resulting head and chest accelerations tended to lag the Hybrid III acceleration trace and have a lower peak value. The results of the injury metric comparison identified possible injury trends between simulations. Risk of head injury was highest for the lateral simulations. The risk of chest injury was highest for the rear impact. However, neck injury risk was approximately the same for all simulations. The injury metric value for lumbar spine force was highest for the spinal impact. The leg forces were highest for the rear and lateral impacts. The results of this comparison indicate the THUMS model performs in a similar manner as the Hybrid III ATD. The differences in the responses of model and the ATD are primarily due to the flexibility of the THUMS. This flexibility of the THUMS would be a more human like response. Based on the similarity between the two models, the THUMS should be used in further testing to assess risk of injury to the occupant.

Currie-Gregg, Nancy J.↗

Miniaturized, High-Speed, Modulated X-Ray Source

A low-cost, miniature x-ray source has been developed that can be modulated in intensity from completely off to full intensity on nanosecond timescales. This modulated x-ray source (MXS) has no filaments and is extremely rugged. The energy level of the MXS is adjustable from 0 to more than 100 keV. It can be used as the core of many new devices, providing the first practical, arbitrarily time-variable source of x-rays. The high-speed switching capability and miniature size make possible many new technologies including x-ray-based communication, compact time-resolved x-ray diffraction, novel x-ray fluorescence instruments, and low- and precise-dose medical x-rays. To make x-rays, the usual method is to accelerate electrons into a target material held at a high potential. When the electrons stop in the target, x-rays are produced with a spectrum that is a function of the target material and the energy to which the electrons are accelerated. Most commonly, the electrons come from a hot filament. In the MXS, the electrons start off as optically driven photoelectrons. The modulation of the x-rays is then tied to the modulation of the light that drives the photoelectron source. Much of the recent development has consisted of creating a photoelectrically-driven electron source that is robust, low in cost, and offers high intensity. For robustness, metal photocathodes were adopted, including aluminum and magnesium. Ultraviolet light from 255- to 350-nm LEDs (light emitting diodes) stimulated the photoemissions from these photocathodes with an efficiency that is maximized at the low-wavelength end (255 nm) to a value of roughly 10(exp -4). The MXS units now have much higher brightness, are much smaller, and are made using a number of commercially available components, making them extremely inexpensive. In the latest MXS design, UV efficiency is addressed by using a high-gain electron multiplier. The photocathode is vapor-deposited onto the input cone of a Burle Magnum(TradeMark) multiplier. This system yields an extremely robust photon-driven electron source that can tolerate long, weeks or more, exposure to air with negligible degradation. The package is also small. When combined with the electron target, necessary vacuum fittings, and supporting components (but not including LED electronics or high-voltage sources), the entire modulated x-ray source weighs as little as 158 grams.

Gendreau, Keith↗

Studies of RF sheaths and diagnostics on IShTAR

IShTAR (Ion cyclotron Sheath Test ARrangement) is a linear magnetised plasma test facility for RF sheaths studies at the Max-Planck-Institut für Plasmaphysik in Garching. In contrast to a tokamak, a test stand provides more liberty to impose the parameters and gives better access for the instrumentation and antennas. The project will support the development of diagnostic methods for characterising RF sheaths and validate and improve theoretical predictions. The cylindrical vacuum vessel has a diameter of 1 m and is 1.1 m long. The plasma is created by an external cylindrical plasma source equipped with a helical antenna that has been designed to excite the m=1 helicon mode. In inductive mode, plasma densities and electron temperatures have been characterised with a planar Langmuir probe as a function of gas pressure and input RF power. A 2D array of RF compensated Langmuir probes and a spectrometer are planned. A single strap RF antenna has been designed; the plasma-facing surface is aligned to the cylindrical plasma to ease the modelling. The probes will allow direct measurements of plasma density profiles in front of the RF antenna, and thus a detailed study of the density modifications induced by RF sheaths, which influences the coupling. The RF antenna frequency has been chosen to study different plasma wave interactions: the accessible plasma density range includes an evanescent and propagative behaviour of slow or fast waves, and allows the study of the effect of the lower hybrid resonance layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Athena Mars Rover Science Payload

The Mars Surveyor missions that will be launched in April of 2001 will include a highly capable rover that is a successor to the Mars Pathfinder mission's Sojourner rover. The design goals for this rover are a total traverse distance of at least 10 km and a total lifetime of at least one Earth year. The rover's job will be to explore a site in Mars' ancient terrain, searching for materials likely to preserve a record of ancient martian water, climate, and possibly biology. The rover will collect rock and soil samples, and will store them for return to Earth by a subsequent Mars Surveyor mission in 2005. The Athena Mars rover science payload is the suite of scientific instruments and sample collection tools that will be used to perform this job. The specific science objectives that NASA has identified for the '01 rover payload are to: (1) Provide color stereo imaging of martian surface environments, and remotely-sensed point discrimination of mineralogical composition. (2) Determine the elemental and mineralogical composition of martian surface materials. (3) Determine the fine-scale textural properties of these materials. (4) Collect and store samples. The Athena payload has been designed to meet these objectives. The focus of the design is on field operations: making sure the rover can locate, characterize, and collect scientifically important samples in a dusty, dirty, real-world environment. The topography, morphology, and mineralogy of the scene around the rover will be revealed by Pancam/Mini-TES, an integrated imager and IR spectrometer. Pancam views the surface around the rover in stereo and color. It uses two high-resolution cameras that are identical in most respects to the rover's navigation cameras. The detectors are low-power, low-mass active pixel sensors with on-chip 12-bit analog-to-digital conversion. Filters provide 8-12 color spectral bandpasses over the spectral region from 0.4 to 1.1 micron Narrow-angle optics provide an angular resolution of 0.28 mrad/pixel, nearly a factor of four higher than that of the Mars Pathfinder and Mars Surveyor '98 cameras. Image compression will be performed using a wavelet compression algorithm. The Mini-Thermal Emission Spectrometer (Mini-TES) is a point spectrometer operating in -the thermal IR. It produces high spectral resolution (5 /cm) image cubes with a wavelength range of 5-40 gm, a nominal signal/noise ratio of 500:1, and a maximum angular resolution of 7 mrad (7 cm at a distance of 10 in). The wavelength region over which it operates samples the diagnostic fundamental absorption features of rockforming minerals, and also provides some capability to see through dust coatings that could tend to obscure spectral features. The mineralogical information that Mini-TES provides will be used to select from a distance the rocks and soils that will be investigated in more detail and ultimately sampled. Mini-TES is derived from the MO/MGS TES instrument, but is significantly smaller and simpler. The instrument uses an 8-cm Cassegrain telescope, a Michelson interferometer, and uncooled pyroelectric detectors. Along with its mineralogical capabilities, Mini-TES can provide information on the thermophysical properties of rocks and soils. Viewing upward, it can also provide temperature profiles through the martian atmospheric boundary layer. Elemental and Mineralogical Composition: Once promising samples have been identified from a distance using Pancam/Mini-TES, they will be studied in detail using up to three compositional sensors that can be placed directly against them by an Instrument Arm. The two compositional sensors, presently on the payload are an Alpha-Proton-X-Ray Spectrometer (APXS), and a Mossbauer Spectrometer. The APXS is derived closely from the instrument that flew on Mars Pathfinder. Radioactive alpha sources and three detection modes (alpha, proton, and x-ray) provide elemental abundances of rocks and soils to complement and constrain mineralogical data. The Athena APXS will have a revised mechanical design that will cut down significantly on backscattering of alpha particles from martian atmospheric carbon. It will also include a target of known elemental composition that will be used for calibration purposes. The Athena Mossbauer Spectrometer is a diagnostic instrument for the mineralogy and oxidation state of Fe-bearing phases, which are particularly important on Mars. The instrument measures the resonant absorption of gamma rays produced by a Co-57 source to determine splitting of nuclear energy levels in Fe atoms that is related to the electronic environment surrounding them. It has been under development for space flight for many years at the Technical University of Darmstadt. The Mossbauer Spectrometer (and the other arm instruments) will be able to view a small permanent magnet array that will attract magnetic particles in the martian soil. The payload may also include a Raman Spectrometer. If included, the Raman Spectrometer will provide precise identification of major and minor mineral phases. It requires no sample preparation, and is also sensitive to organics. Fine-Scale Texture: The Instrument Arm a also carries a Microscopic Imager that will obtain high-resolution monochromatic images of the same materials for which compositional data will be obtained. Its spatial resolution is 20 micron/pixel over a 1 cm depth of field, and 40 micron/pixel over a 1-cm depth of field. Like Pancam, it uses the same active pixel sensor detectors and electronics as the rover's navigation cameras. The Instrument Arm is a three degree-of-freedom arm that uses designs and components from the Mars Pathfinder and Mars Surveyor '98 projects. Its primary function is instrument positioning. Along with the instruments noted above, it also carries a brush that can be used to remove dust and other loose coatings from rocks. Sample Collection and Storage: Martian rock and soil samples will be collected using a low-power rotary coring drill called the Mini-Corer. An important characteristic of this device is that it can obtain intact samples of rock from up to 5 cm within strong boulders and bedrock, Nominal core dimensions are 8xl7 mm. The Mini-Corer drills a core to the commanded depth in a rock, shears it off, retains it, and extracts it. It can also acquire samples of loose soil, using soil sample cups that are pressed downward into loose material. The Mini-Corer can drill at angles from vertical to 45' off vertical. It has six interchangeable bits for long life. Mechanical damage to the sample during drilling is minimal, and heating is negligible. After acquisition, the sample may be viewed by the arm instruments, and/or placed in one of 104 compartments in the Sample Container. A subset of the acquired samples may be replaced with other samples obtained later if desired. The Sample Container has no moving parts, and is mounted external to the rover for easy removal by the Mars Surveyor 2005 flight system. Operation of the rover will make extensive use of automated onboard navigation and hazard avoidance capabilities. Otherwise, use of onboard autonomy is minimal. Data downlink capability is about 40 Mbit/sol, and the use of the Mars Surveyor '01 orbiter for data relay imposes a limit of at most two command cycles per sol. Because of the significant amount of time available between command cycles, all payload elements will be operated sequentially, rather than in parallel.; this approach also significantly simplifies operations and minimizes peak power usage. The landing site for the '01 rover has not been selected yet. Site selection will make as full use as possible of Mars Global Surveyor data, and will involve substantial input from the broad Mars science community. Summary: The following table describes the mass, power, providers, and key scientific objectives of all the major elements of the Athena payload. Additional Athena payload information may be found at: http://astrosun.tn.cornell.edu/athena/index.html. Additional information contained in the original.

Squyes, S. W.↗

Scanning Tunneling Optical Resonance Microscopy

Scanning tunneling optical resonance microscopy (STORM) is a method, now undergoing development, for measuring optoelectronic properties of materials and devices on the nanoscale by means of a combination of (1) traditional scanning tunneling microscopy (STM) with (2) tunable laser spectroscopy. In STORM, an STM tip probing a semiconductor is illuminated with modulated light at a wavelength in the visible-to-near-infrared range and the resulting photoenhancement of the tunneling current is measured as a function of the illuminating wavelength. The photoenhancement of tunneling current occurs when the laser photon energy is sufficient to excite charge carriers into the conduction band of the semiconductor. Figure 1 schematically depicts a proposed STORM apparatus. The light for illuminating the semiconductor specimen at the STM would be generated by a ring laser that would be tunable across the wavelength range of interest. The laser beam would be chopped by an achromatic liquid-crystal modulator. A polarization-maintaining optical fiber would couple the light to the tip/sample junction of a commercial STM. An STM can be operated in one of two modes: constant height or constant current. A STORM apparatus would be operated in the constant-current mode, in which the height of the tip relative to the specimen would be varied in order to keep the tunneling current constant. In this mode, a feedback control circuit adjusts the voltage applied to a piezoelectric actuator in the STM that adjusts the height of the STM tip to keep the tunneling current constant. The exponential relationship between the tunneling current and tip-to-sample distance makes it relatively easy to implement this mode of operation. The choice of method by which the photoenhanced portion of the tunneling current would be measured depends on choice of the frequency at which the input illumination would be modulated (chopped). If the frequency of modulation were low enough (typically < 10 Hz) that the feedback circuit could respond, then the voltage applied to the piezoelectric tip-height actuator could be measured by use of a lock-in amplifier locked to the modulation (chopping) signal. However, at a high modulation frequency (typically in the kilohertz range or higher), the feedback circuit would be unable to respond. In this case, the photoenhanced portion of the tunneling current could be measured directly. For this purpose, the tunneling current would be passed through a precise resistor and the voltage drop would be measured by use of the lock-in amplifier.

Bailey, Sheila↗

Timely Reporting of Heavy Hitters Using External Memory

Given an input stream S of size N, a Φ-heavy hitter is an item that occurs at least ΦN times in S. The problem of finding heavy-hitters is extensively studied in the database literature. In this work, we study a real-time heavy-hitters variant in which an element must be reported shortly after we see its T = Φ N-th occurrence (and hence it becomes a heavy hitter). We call this the Timely Event Detection (TED) Problem. The TED problem models the needs of many real-world monitoring systems, which demand accurate (i.e., no false negatives) and timely reporting of all events from large, high-speed streams with a low reporting threshold (high sensitivity). Like the classic heavy-hitters problem, solving the TED problem without false-positives requires large space (Ω (N) words). Thus in-RAM heavy-hitters algorithms typically sacrifice accuracy (i.e., allow false positives), sensitivity, or timeliness (i.e., use multiple passes). We show how to adapt heavy-hitters algorithms to external memory to solve the TED problem on large high-speed streams while guaranteeing accuracy, sensitivity, and timeliness. Our data structures are limited only by I/O-bandwidth (not latency) and support a tunable tradeoff between reporting delay and I/O overhead. With a small bounded reporting delay, our algorithms incur only a logarithmic I/O overhead. We implement and validate our data structures empirically using the Firehose streaming benchmark. Multi-threaded versions of our structures can scale to process 11M observations per second before becoming CPU bound. In comparison, a naive adaptation of the standard heavy-hitters algorithm to external memory would be limited by the storage device’s random I/O throughput, i.e., ≈100K observations per second.

97 MATHEMATICS AND COMPUTING↗

Results and lessons learned from accelerating radio frequency modeling using machine learning [slides]

The “advanced tokamak” reactor concept is a leading candidate for a steady state fusion pilot plant. An advanced tokamak (AT) sustains a majority of the required plasma current with effects resulting from maintenance of the peaked pressure at the device center. This current is augmented by auxiliary current drive sources. These auxiliary actuators may consist of neutral particle beams and/or radio frequency (RF) systems such as lower hybrid current drive (LHCD) and high harmonic fast wave (HHFW) current drive using radio and microwaves from antennas. The primary focus of this work is to develop models of RF current profile control suitable for use in integrated modeling frameworks and for real-time control in experiments. Direct physics models of RF current drive can be computationally intensive. In order to achieve predictive times appropriate for the thousands of calls needed in real-time control of experiments and for use in integrated models, we will apply modern machine learning (ML) techniques to accelerate these models and interpolate their results. To generate the fast and accurate models for use in control level algorithms and integrated modeling we need to replace present models with high dimensional interpolation of their results. We will perform additional simulations across a broader parameter range for EAST and other tokamaks in different physics regimes (Alcator C-Mod, DIII-D, WEST, CFETR, ARC, ITER) and combine them into a larger database for training and testing of the ML models. Further testing of the control level models with experimental current profile data from EAST and C-Mod tokamaks will provide additional confirmation of the control level model before integration in a tokamak control system or integrated modeling suite. ML will be used to optimize the selection of training data consisting of RF current driven at different values of density profile, temperature profile, plasma current, and wavenumber. ML will also be used to facilitate classification of current drive from these input data. The output of this effort will be a validated classifier capable of determining the current drive profiles for HHFW CD and LHCD on a mille-second timescale. This will provide a breakthrough capability enabling real-time control of RF driven current profiles in experiments including ITER ICRF and use integrated modeling frameworks requiring thousands of current profile calculations in discharge simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-Chip T/R Module for 1.2 GHz

A single-chip CMOS-based (complementary-metal-oxide-semiconductorbased) transmit/receive (T/R) module is being developed for L-band radar systems. Previous T/R module implementations required multiple chips employing different technologies (GaAs, Si, and others) combined with off-chip transmission lines and discrete components including circulators. The new design eliminates the bulky circulator, significantly reducing the size and mass of the T/R module. Compared to multi-chip designs, the single-chip CMOS can be implemented with lower cost. These innovations enable cost-effective realization of advanced phased array and synthetic aperture radar systems that require integration of thousands of T/R modules. The circulator is a ferromagnetic device that directs the flow of the RF (radio frequency) power during transmission and reception. During transmission, the circulator delivers the transmitted power from the amplifier to the antenna, while preventing it from damaging the sensitive receiver circuitry. During reception, the circulator directs the energy from the antenna to the low-noise amplifier (LNA) while isolating the output of the power amplifier (PA). In principle, a circulator could be replaced by series transistors acting as electronic switches. However, in practice, the integration of conventional series transistors into a T/R chip introduces significant losses and noise. The prototype single-chip T/R module contains integrated transistor switches, but not connected in series; instead, they are connected in a shunt configuration with resonant circuits (see figure). The shunt/resonant circuit topology not only reduces the losses associated with conventional semiconductor switches but also provides beneficial transformation of impedances for the PA and the LNA. It provides full singlepole/ double-throw switching for the antenna, isolating the LNA from the transmitted signal and isolating the PA from the received signal. During reception, the voltage on control line RX/TX (raised bar) is high, causing the field-effect transistor (FET) switch S1 to be closed, forming a parallel resonant tank circuit L1||C1. This circuit presents high impedance to the left of the antenna, so that the received signal is coupled to the LNA. At the same time, FET switches S2 and S3 are open, so that C2 is removed from the circuit (except for a small parasitic capacitance). The combination of L2 and C3 forms a matching network that transforms the antenna impedance of 50 ohms to a higher value from the perspective of the LNA input terminal. This transformation of impedance improves LNA noise figure by increasing the received voltage delivered to the input transistor. This allows lower transconductance and therefore a smaller transistor, which makes it possible to design the CMOS LNA for low power consumption. During transmission, the voltage on control line RX/TX (raised bar) is low, causing switch S1 to be open. In this configuration, the combination of L1 and C1 transforms the antenna impedance to a lower value from the perspective of the PA. This low impedance is helpful in producing a relatively high output power compatible with the low CMOS operating potential. At the same time, switches S2 and S3 are closed, forming the parallel resonant tank circuit L2||C2. This circuit presents high impedance to the right of the antenna, directing the PA output signal to the antenna and away from the LNA. During this time, S3 presents a short circuit across the LNA input terminals to guarantee that the voltage seen by the LNA is small enough to prevent damage.

Moussessian, Alina↗

Current-Source Solid-State DC Transformer Integrating LVDC Microgrid, Energy Storage, and Renewable Energy Into MVDC Grid

Solid-state DC transformer to integrate low-voltage DC (LVDC) microgrid, wind turbine (WT) generator, photovoltaic (PV), and energy storage (ES) into medium-voltage (MV) direct-current (MVDC) distribution grids is attractive. This paper proposes current-source DC solid-state transformer (SST) for MVDC collection system in WT, PV, and ES farms or as an interface between the MVDC grid and the LVDC microgrid. Compared to conventional current-source converter (CSC) based SSTs, a switch reduction scheme on reverse-blocking device bridges is proposed to reduce device count and the number of devices on the DC-link current path. Importantly, the proposed switch reduction scheme is generic and can be applied to the DC ports of DC-AC, AC-DC, or DC-DC hard-switching or soft-switching CSC-based SSTs. Based on this scheme, the proposed current-source DC SSTs are derived, which have reduced electrolytic-capacitor-less DC-link. The proposed DC SSTs also achieve single-stage isolated DC-DC or DC-AC conversion, full-range zero-voltage switching (ZVS) for main switches, zero-current switching (ZCS) for resonant switches, and controlled dv/dt. The proposed DC SSTs, operating principles, predictive control method, the ZVS, and the controlled dv/dt under voltage buck-boost ranges are verified with MV simulations and an experimental prototype based on SiC MOSFETs, diodes, and a nanocrystalline transformer.

14 SOLAR ENERGY↗