Search NASA⌕ Search

SEARCH · Search NASA

Results for “load changes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

TRITIUM IN-BED ACCOUNTABILITY FOR A PASSIVELY COOLED, ELECTRICALLY HEATED HYDRIDE BED

A PAssively Cooled, Electrically heated hydride (PACE) Bed has been deployed into tritium service in the Savannah River Site (SRS) Tritium Facilities. The bed design, absorption and desorption performance, and cold (non-radioactive) in-bed accountability (IBA) results have been reported previously. Six PACE Beds were fitted with instrumentation to perform the steady-state, flowing gas calorimetric inventory method. An IBA inventory calibration curve, flowing gas temperature rise ({Delta}T) versus simulated or actual tritium loading, was generated for each bed. Results for non-radioactive ('cold') tests using the internal electric heaters and tritium calibration results are presented. Changes in vacuum jacket pressure significantly impact measured IBA {Delta}T values. Higher jacket pressures produce lower IBA {Delta}T values which underestimate bed tritium inventories. The exhaust pressure of the IBA gas flow through the bed's U-tube has little influence on measured IBA {Delta}T values, but larger gas flows reduce the time to reach steady-state conditions and produce smaller tritium measurement uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗

Standardization of tritium measuring devices based on a high-sensitivity calorimeter

A twin type thermal conduction calorimeter has been specially designed and constructed for absolute measurement of tritium, and then its performance was examined using two kinds of tritium samples, i.e., ZrNi alloy powders loaded with a given amount of tritium. Total amounts of tritium in the ZrNi alloy powders were previously estimated by a small ionization chamber. Changes in radioactivity of two samples were followed for three years, and it was seen that the activity changes obeys the half-life of 4505 days. The initial tritium amounts estimated by the small ionization chamber agreed well with the extrapolated values from the activity changes evaluated by the calorimeter. Namely, it was suggested that the small ionization chamber is able to be used as a secondary standard of the tritium measuring devices. The {beta}-ray-induced X-ray counter was also calibrated for non-destructive measurements of high-level tritium by using the present small ionization chamber. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer↗

Interconnects

The identification and fabrication of suitable interconnect materials is a major challenge in the development of SOFCs [1,2]. The primary function of the interconnect is to carry electrical current from the electrochemical cell to the external circuit, so the inteconnect material must have good electrical conductivity. In addition, the interconnect must be chemically and mechanically stable for operation at high temperatures for long periods of time. This is especially challenging, since the interconnect is exposed to both oxidizing conditions at the cathode and reducing conditions at the anode. Thus, interconnect materials should not undergo significant dimensional changes with changes in either temperature or oxygen partial pressure. One such change is thermal expansion, which must be matched with the expansion of other fuel cell components to avoid the generation of thermal stresses during heating or cooling. Similarly, some materials undergo expansion or contraction with changes in oxygen partial pressure, which can also lead to stresses in the fuel cell. Thus, although the interconnect is not always a load-bearing component, moderate mechanical strength of the interconnect material is required to avoid fracture when stresses are generated during operation. Even higher strength is required in some planar designs were the interconnect provides structural support. In such designs, the interconnect also separates the fuel from air, so oxygen and hydrogen permeability should be low. The interconnect material must also be chemically stable with other fuel cell components. This includes not only stability during fuel cell operation, but also during fabrication, which typically involves higher temperatures. Finally, ease of fabrication and cost are important so that application of the fuel cell is economically feasible.

08 HYDROGEN↗

Dynamic compression effects of H 2 ⁡O in a dynamic diamond anvil cell: Origin of metastable ice VII and its crystal growth kinetics

We report on the structural verification of metastable ice VII solidifying in the phase space of ice VI at 1.80 GPa at room temperature. Using time-resolved (TR) x-ray diffraction and TR ruby luminescence paired with high-speed microphotography utilizing a dynamic diamond anvil cell, an initial compression rate range from 0.12 to 95.84 GPa/s was explored. The solidification pressure of metastable ice VII has a potential sigmoidal dependence upon compression rate with a turnover compression rate of ∼80 GPa/s. The preferred crystallization of ice VII in the stability field of ice VI is due to the increased nucleation rate of ice VII over ice VI at 1.77 GPa that is driven by the surface energy difference between the liquid and solid phases along with the change in Gibbs free energy of solidification. The dynamic pressure-volume–compression behaviors of ice phases (VI and VII) show a lattice stiffening in both phases, especially during the compression loading. It is also found that the compression rate greatly affects the solid-solid phase transition between ice VI and VII but does not affect the liquid-solid transition between water and ice VI as much. Lastly, a third phase transition was found to occur after metastable ice VII transforms into high-density amorphous (HDA) ice, which could be a disordered hydrogen-bonded network configuration of ice VII forming out of HDA ice facilitated by the decoupling of the oxygen movement and reorientation of the H 2⁡ O molecule. These results demonstrate the complexity of a seemingly simple molecule H 2⁡ O, how it can readily change its static properties with the modification of (de)compression rate, and highlight the need to use multiple TR structural and spectroscopic probes at higher time resolutions to realize the most comprehensive understanding.

Chemical bonding↗

Modeling, Analysis, and Control of Demand Response Resources

While the traditional goal of an electric power system has been to control supply to fulfill demand, the demand-side can plan an active role in power systems via Demand Response (DR), defined by the Department of Energy (DOE) as “a tariff or program established to motivate changes in electric use by end-use customers in response to changes in the price of electricity over time, or to give incentive payments designed to induce lower electricity use at times of high market prices or when grid reliability is jeopardized” [29]. DR can provide a variety of benefits including reducing peak electric loads when the power system is stressed and fast timescale energy balancing. Therefore, DR can improve grid reliability and reduce wholesale energy prices and their volatility. This dissertation focuses on analyzing both recent and emerging DR paradigms. Recent DR programs have focused on peak load reduction in commercial buildings and industrial facilities (C&I facilities). We present methods for using 15-minute-interval electric load data, commonly available from C&I facilities, to help building managers understand building energy consumption and ‘ask the right questions’ to discover opportunities for DR. Additionally, we present a regression-based model of whole building electric load, i.e., a baseline model, which allows us to quantify DR performance. We use this baseline model to understand the performance of 38 C&I facilities participating in an automated dynamic pricing DR program in California. In this program, facilities are expected to exhibit the same response each DR event. We find that baseline model error makes it difficult to precisely quantify changes in electricity consumption and understand if C&I facilities exhibit event-to-event variability in their response to DR signals. Therefore, we present a method to compute baseline model error and a metric to determine how much observed DR variability results from baseline model error rather than real variability in response. We find that, in general, baseline model error is large. Though some facilities exhibit real DR variability, most observed variability results from baseline model error. In some cases, however, aggregations of C&I facilities exhibit real DR variability, which could create challenges for power system operation. These results have implications for DR program design and deployment. Emerging DR paradigms focus on faster timescale DR. Here, we investigate methods to coordinate aggregations of residential thermostatically controlled loads (TCLs), including air conditioners and refrigerators, to manage frequency and energy imbalances in power systems. We focus on opportunities to centrally control loads with high accuracy but low requirements for sensing and communications infrastructure. Specifically, we compare cases when measured load state information (e.g., power consumption and temperature) is 1) available in real time; 2) available, but not in real time; and 3) not available. We develop Markov Chain models to describe the temperature state evolution of heterogeneous populations of TCLs, and use Kalman filtering for both state and joint parameter/state estimation. We present a look-ahead proportional controller to broadcast control signals to all TCLs, which always remain in their temperature dead-band. Simulations indicate that it is possible to achieve power tracking RMS errors in the range of 0.26–9.3% of steady state aggregated power consumption. Results depend upon the information available for system identification, state estimation, and control. We find that, depending upon the performance required, TCLs may not need to provide state information to the central controller in real time or at all. We also estimate the size of the TCL potential resource; potential revenue from participation in markets; and break-even costs associated with deploying DR-enabling technologies. We find that current TCL energy storage capacity in California is 8–11 GWh, with refrigerators contributing the most. Annual revenues from participation in regulation vary from $10 to $220 per TCL per year depending upon the type of TCL and climate zone, while load following and arbitrage revenues are more modest at $2 to $35 per TCL per year. These results lead to a number of policy recommendations that will make it easier to engage residential loads in fast timescale DR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvement of a plasma uniformity of the 2nd ion source of KSTAR neutral beam injector

The 2nd ion source of KSTAR (Korea Superconducting Tokamak Advanced Research) NBI (Neutral Beam Injector) had been developed and operated since last year. A calorimetric analysis revealed that the heat load of the back plate of the ion source is relatively higher than that of the 1st ion source of KSTAR NBI. The spatial plasma uniformity of the ion source is not good. Therefore, we intended to identify factors affecting the uniformity of a plasma density and improve it. We estimated the effects of a direction of filament current and a magnetic field configuration of the plasma generator on the plasma uniformity. We also verified that the operation conditions of an ion source could change a uniformity of the plasma density of an ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Changes in the surfaces on DDOAB organoclays adsorbed with paranitrophenol-An XRD, TEM and TG study

The adsorption of paranitrophenol on organoclays synthesised by the ion exchange of the surfactant molecule dimethyldioctadecylammonium bromide (DDOAB) of formula (CH{sub 3}(CH{sub 2}){sub 17}){sub 2}NBr(CH{sub 3}){sub 2} has been studied by X-ray diffraction (XRD), transmission electron microscopy (TEM) and thermogravimetric analysis. The expansion of the montmorillonite depends on the loading of the montmorillonite with dimethyldioctadecylammonium bromide and is related to the arrangement of the surfactant molecules within the clay interlayer. This expansion is altered by the adsorbed paranitrophenol and is observed in the transmission electron microscopic images of the organoclay with adsorbed paranitrophenol. Changes in the surfactant molecular arrangements were analysed by thermogravimetry. The paranitrophenol is sublimed simultaneously with the loss of surfactant. The dehydroxylation temperature of the montmorillonite is decreased upon adsorption of the paranitrophenol indicating a bonding between the paranitrophenol and the hydroxyl units of the montmorillonite.

36 MATERIALS SCIENCE↗

Impacts of LEU+ and ATF on Fresh Fuel Storage Criticality Safety

The use of increased fuel enrichment, which is still in the realm of low-enriched uranium (LEU) fuel, has been of interest to commercial light water reactor operators as part of the next iteration in fuel cycle technological advances and research and development. Using increased enrichment fuel, or high-assay LEU (HALEU), in power plants has clear benefits for being able to load cores with additional power-producing fuel. Although HALEU enrichments can range up to 20%, the more guarded approach of investigating enrichments above current fuels within 10% enrichment is referred to as LEU plus (LEU+) to reflect the less drastic change in operating conditions and requirements and similarity to current fuel cycles. Of additional interest and increasing maturity is the incorporation of accident-tolerant fuel (ATF) concepts, which are also applicable to the current fleet. This class of technologies involves changes such as cladding (e.g., chromium coating or FeCrAl) and fuel composition (e.g., chromia dopant) alterations to demonstrate improved fuel performance under accident scenarios. The ability to properly store fuel before and after residence time in the reactor is crucial to plant operation. Typically, this is done in either a new fuel vault (NFV) or spent fuel pool (SFP). Storing, loading, and unloading dozens of fuel assemblies within the same general area provides opportunities for obvious criticality concerns. These concerns are addressed with regulations to the subcriticality margin that the NFV and SFP must maintain in certain conditions. Adopting LEU+ fuel results in inherent reactivity increases, which are extremely relevant for safe fuel storage. Therefore, a clear understanding of the effects of LEU+ fuel and ATF on criticality safety margins to regulatory limits is required, as well as an understanding of the degree of absorber crediting under normal and accident conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

MELT RATE TESTING FOR SLUDGE BATCH 6

The Savannah River National Laboratory (SRNL) was requested to provide Savannah River Remediation (SRR) with a recommended frit composition for Sludge Batch 6 (SB6) to optimize processing at the Defense Waste Processing Facility (DWPF). This report discusses the results of a series of melt rate experiments that were completed in support of the frit recommendation and the preparation of the feed used in the testing. The objective of the work was to identify the impact of individual frit component concentrations on melt rate for both SB6 and for DWPF sludge batches in general. The dry fed, Melt Rate Furnace (MRF) was used to compare the relative melt rate performance of several candidate frit compositions. Sludge composition projection changes and variation led to the fabrication and testing of several new frits along with Frit 418, which is currently utilized at the DWPF for Sludge Batch 5 (SB5) processing. The melt rate testing results show that changes in the frit composition, such as increases in B{sub 2}O{sub 3} or Li{sub 2}O concentrations, can provide a faster melt rate for SB6 relative to Frit 418. However, the composition of SB6 as currently projected (February 2010 blended with a 40 inch heel of SB5) does not allow for significant changes in frit composition relative to Frit 418 without compromising the projected operating windows. Only one of the new frits tested, Frit IS7, remains viable for SB6 processing based on the current composition projections. The melt rate results also demonstrated that a low Na{sub 2}O concentration frit (particularly Frit IS7) can provide reasonable melt rates if the concentrations of Li{sub 2}O or B{sub 2}O{sub 3} in the frit are increased. The measured melt rate for Frit IS7 with the simulated SB6 feed was about 15% faster than that for Frit 418. The projected operating windows for Frits 418 and IS7 are very similar with the current SB6 projections. However, waste loadings with Frit IS7 are limited by low viscosity predictions, while waste loadings with Frit 418 are limited by predictions of nepheline crystallization. It is recommended that SRNL reevaluate the final SB6 composition once washing and blending are complete to determine whether a change in frit composition could provide improved operating windows, improved sulfate solubility, and/or increased waste throughput.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Direct Visualization of Drug–Polymer Phase Separation in Ritonavir–Copovidone Amorphous Solid Dispersions Using in situ Synchrotron X-ray Fluorescence Imaging of Thin Films

Amorphous solid dispersions (ASDs) are new formulations currently being used in pharmaceutical industry. The ASDs, in which amorphous drug and polymeric excipients are intimately mixed at a molecular level, exhibit dramatically enhanced solubility and dissolution characteristics relative to their crystalline drug counterparts. In the process of achieving an ever-increasing drug loading (DL), it is noticed however, that the drug release profile deteriorates significantly beyond a certain DL. As an example, a ritonavir-copovidone ASD achieves continuous and full drug release when DL ≤ 25 wt%. The release drops at 30 wt% and when DL > 30 wt% there is virtually no drug release, behaving like a pure amorphous drug. In this communication, the dissolution behavior of ASD thin films has been investigated by in situ synchrotron X-ray fluorescence (XRF) imaging to elucidate the mechanism for the unique change in extent of drug release as a function of DL. It is found that the drug release profile correlates well with the amorphous-amorphous phase separation (AAPS) onset. At a lower drug loading (up to 20 wt%), it takes more than 12 hours for AAPS to happen while in sharp contrast, it only needs less than 10 minutes for DL > 30 wt%. During AAPS amorphous drug accumulates on the surface of the film which prevents further dissolution from the interior of the ASD. The current study provides a mechanistic understanding of the confounding drug release profile of ASDs as a function of DL, and opens the door for studying drug-excipient (e.g. polymer, surfactant) interactions via XRF imaging in the future.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A numerical study of latent thermal energy storage in a phase change material/carbon panel

To reduce the energetic dependence of building, it has become necessary to explore and develop new materials promoting energy conservation. Because of their high storage capacity, phase change materials (PCMs) are efficient to store thermal energy. In this paper, a 3D model was studied for simulation of energy storing cycles to predict the performances of PCM loaded panels. Carbon was used as supporting material for the PCM. The simulation was based on the enthalpy method using Ansys Fluent software. The panel was exposed to a daily heat flow including the effects of convection and radiation. The results show that the temperature decreased of approximately 2.5°C with a time shift about 2 hours. The steady state was reached after four cycles. Thus, after four cycles the PCM showed its effects on the temperature conditioning.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hydrolysis‐determining substrate characteristics in liquid hot water pretreated hardwood

ABSTRACT Fundamental characterization of pretreated hardwood and its interactions with cellulolytic enzymes has confirmed that a pathway exists for dramatically reducing the loading of cellulase required for hydrolysis of pretreated biomass. We demonstrate that addition of protein effecting a seven‐fold decrease in the specific activity of cellulases enables a ten‐fold reduction in enzyme loading while maintaining a high level of cellulose hydrolysis in pretreated hardwood. While use of protein and other additives that adsorb on lignin have been reported previously, the current work demonstrates the effect in a dramatic manner and brings the rationale for this change into clear focus. The key to this result is recognizing and mitigating the pretreatment conundrum where increasingly severe pretreatment conditions enhance accessibility of the enzymes not only to cellulose, but also to lignin. The lignin adsorbs enzyme protein causing loss of cellulase activity. More enzyme, added to compensate for this lost activity, results in a higher cellulase loading. The addition of a different protein, such as BSA, prevents cellulase adsorption on lignin and enables the enzyme itself to better target its glucan substrate. This effect dramatically reduces the amount of cellulase for a given level of conversion with enzyme loadings of 15 FPU and 1.3 FPU/g solids both achieving 80% conversion. The understanding of this phenomenon reinvigorates motivation for the search for other approaches that prevent cellulase adsorption on lignin in order to achieve high glucose yields at low enzyme loadings for pretreated lignocellulose. Biotechnol. Bioeng. 2015;112: 677–687. © 2014 Wiley Periodicals, Inc.

Kim, Youngmi↗

Scattering Studies of Hydrophobic Monomers in Liposomal Bilayers: An Expanding Shell Model of Monomer Distribution

Hydrophobic monomers partially phase separate from saturated lipids when loaded into lipid bilayers in amounts exceeding a 1:1 monomer/lipid molar ratio. This conclusion is based on the agreement between two independent methods of examining the structure of monomer-loaded bilayers. Complete phase separation of monomers from lipids would result in an increase in bilayer thickness and a slight increase in the diameter of liposomes. A homogeneous distribution of monomers within the bilayer would not change the bilayer thickness and would lead to an increase in the liposome diameter. The increase in bilayer thickness, measured by the combination of small-angle neutron scattering (SANS) and small-angle X-ray scattering (SAXS), was approximately half of what was predicted for complete phase separation. The increase in liposome diameter, measured by dynamic light scattering (DLS), was intermediate between values predicted for a homogeneous distribution and complete phase separation. Combined SANS, SAXS, and DLS data suggest that at a 1.2 monomer/lipid ratio approximately half of the monomers are located in an interstitial layer sandwiched between lipid sheets. These results expand our understanding of using self-assembled bilayers as scaffolds for the directed covalent assembly of organic nanomaterials. In particular, the partial phase separation of monomers from lipids corroborates the successful creation of nanothin polymer materials with uniform imprinted nanopores. Finally, pore-forming templates do not need to span the lipid bilayer to create a pore in the bilayer-templated films.

59 BASIC BIOLOGICAL SCIENCES↗

Examination of the cerium α-ε phase transition under dynamic loading with x-ray diffraction

Recent examination of the cerium Hugoniot with pyrometry and x-ray diffraction (XRD) has revealed a narrow solid-liquid two-phase region. It has been suggested that nonequilibrium melting may be occurring along the Ce Hugoniot, with either melt kinetics or a sluggish α-ε transition impeding the transition. In particular, the kinetics of the α-ε is unknown and the location of the phase boundary is in dispute. Static measurements suggest a nearly vertical phase boundary that intersects the Hugoniot at 6–7 GPa. This lies in direct conflict with dynamic measurements along the Hugoniot observing α-Ce through incipient melt. This work presents dynamic experiments using XRD to examine the behavior of the α-ε phase transition. The results show that the α-ε phase transition occurs through a tetragonal distortion, with the transition beginning at temperatures below the solid Hugoniot. Following the initial deviation from an ideal fcc structure, the c/a ratio is found to gradually increase with no steady value observed in the ε phase within the range of these experiments (below 17 GPa). Multiple diffraction patterns captured during the peak stress state show no significant change in c/a ratio prior to uniaxial release, upon which Ce reverts to an fcc structure. Furthermore, the results indicate that the α-ε transition occurs rapidly, both on loading and release. An examination of the c/a ratio with increasing temperatures suggests 11.5 GPa as a lower bound for the location of the α-ε-liquid triple point.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Penetration Photovoltaic Case Study Report

Technical concerns with integrating higher penetrations of photovoltaic (PV) systems include grid stability, voltage regulation, power quality (voltage rise, sags, flicker, and frequency fluctuations), and protection and coordination. The current utility grid was designed to accommodate power flows from the central generation source to the transmission system and eventually to the distribution feeders. At the distribution level, the system was designed to carry power from the substation toward the load. Renewable distributed generation, particularly solar PV, provides power at the distribution level challenging this classical paradigm. As these resources become more commonplace the nature of the distribution network and its operation is changing to handle power flow in both directions. A large portion of distribution system components, including voltage regulators and protection systems, were not designed to coordinate with bidirectional power flow and bidirectional fault currents from distributed generation and PV systems in particular. Coordinating these devices in the presence of high penetration PV areas introduces additional challenges to feasibility and system impact studies. Some cases require modification of existing protection schemes, additional distribution equipment, or reactive power requirements on the PV inverters. This report is focused on large PV installations in which penetration is significantly greater than 15% of maximum daytime feeder load. To date the impact on the electric utility and its customers has not been problematic in any of these cases. The PV system installations described in this report exceeds what most experts consider high penetration scenarios. The voltage, power quality, and other operating parameters have been maintained within the required ranges with minimal negative impact on distribution operations and utility customers. These case studies are intended to demonstrate success stories with integration of large PV plants at the distribution level as well as some of the solutions used by the utility to ensure safe, reliable operation of both the PV system and the distribution network.

14 SOLAR ENERGY↗

Heterogeneous climate change impacts on electricity demand in world cities circa mid-century

Rising ambient temperatures due to climate change will increase urban populations’ exposures to extreme heat. During hot hours, a key protective adaptation is increased air conditioning and associated consumption of electricity for cooling. But during cold hours, milder temperatures have the offsetting effect of reducing consumption of electricity and other fuels for heating. We elucidate the net consequences of these opposing effects in 36 cities in different world regions. We couple reduced-form statistical models of cities’ hourly responses of electric load to temperature with temporally downscaled projections of temperatures simulated by 21 global climate models (GCMs), projecting the effects of warming on the demand for electricity circa 2050. Cities' responses, temperature exposures and impacts are heterogeneous, with changes in total annual consumption ranging from –2.7 to 5.7%, and peak power demand increasing by as much as 9.5% at the multi-GCM median. The largest increases are concentrated in more economically developed mid-latitude cities, with less developed urban areas in the tropics exhibiting relatively small changes. The results highlight the important role of the structure of electricity demand: large temperature increases in tropical cities are offset by their inelastic responses, which can be attributed to lower air-conditioning penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗