Search NASA⌕ Search

SEARCH · Search NASA

Results for “mean squared error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Parameter Estimation in Astronomy with Poisson-Distributed Data: The (CHI)2(gamma) Statistic - 1

Applying the standard weighted mean formula, [Sigma (sub i)n(sub i)ssigma(sub i, sup -2)], to determine the weighted mean of data, n(sub i), drawn from a Poisson distribution, will, on average, underestimate the true mean by approx. 1 for all true mean values larger than approx.3 when the common assumption is made that the error of the i th observation is sigma(sub i) = max square root of n(sub i), 1).This small, but statistically significant offset, explains the long-known observation that chi-square minimization techniques which use the modified Neyman'chi(sub 2) statistic, chi(sup 2, sub N) equivalent Sigma(sub i)((n(sub i) - y(sub i)(exp 2)) / max(n(sub i), 1), to compare Poisson - distributed data with model values, y(sub i), will typically predict a total number of counts that underestimates the true total by about 1 count per bin. Based on my finding that weighted mean of data drawn from a Poisson distribution can be determined using the formula [Sigma(sub i)[n(sub i) + min(n(sub i), 1)](n(sub i) + 1)(exp -1)] / [Sigma(sub i)(n(sub i) + 1)(exp -1))], I propose that a new chi(sub 2) statistic, chi(sup 2, sub gamma) equivalent, should always be used to analyze Poisson- distributed data in preference to the modified Neyman's chi(exp 2) statistic. I demonstrated the power and usefulness of,chi(sub gamma, sup 2) minimization by using two statistical fitting techniques and five chi(exp 2) statistics to analyze simulated X-ray power - low 15 - channel spectra with large and small counts per bin. I show that chi(sub gamma, sup 2) minimization with the Levenberg - Marquardt or Powell's method can produce excellent results (mean slope errors approx. less than 3%) with spectra having as few as 25 total counts.

Mighell, Kenneth J.↗

Solar cell angle of incidence corrections

Literature on solar array angle of incidence corrections was found to be sparse and contained no tabular data for support. This lack along with recent data on 27 GaAs/Ge 4 cm by 4 cm cells initiated the analysis presented in this paper. The literature cites seven possible contributors to angle of incidence effects: cosine, optical front surface, edge, shadowing, UV degradation, particulate soiling, and background color. Only the first three are covered in this paper due to lack of sufficient data. The cosine correction is commonly used but is not sufficient when the incident angle is large. Fresnel reflection calculations require knowledge of the index of refraction of the coverglass front surface. The absolute index of refraction for the coverglass front surface was not known nor was it measured due to lack of funds. However, a value for the index of refraction was obtained by examining how the prediction errors varied with different assumed indices and selecting the best fit to the set of measured values. Corrections using front surface Fresnel reflection along with the cosine correction give very good predictive results when compared to measured data, except there is a definite trend away from predicted values at the larger incident angles. This trend could be related to edge effects and is illustrated by a use of a box plot of the errors and by plotting the deviation of the mean against incidence angle. The trend is for larger deviations at larger incidence angles and there may be a fourth order effect involved in the trend. A chi-squared test was used to determine if the measurement errors were normally distributed. At 10 degrees the chi-squared test failed, probably due to the very small numbers involved or a bias from the measurement procedure. All other angles showed a good fit to the normal distribution with increasing goodness-of-fit as the angles increased which reinforces the very small numbers hypothesis. The contributed data only went to 65 degrees from normal which prevented any firm conclusions about extreme angle effects although a trend in the right direction was seen. Measurement errors were estimated and found to be consistent with the conclusions that were drawn. A controlled experiment using coverglasses and cells from the same lots and extending to larger incidence angles would probably lead to further insight into the subject area.

Burger, Dale R.↗

Parameter identification of linear discrete stochastic systems with time delays

An identification algorithm that uses the maximum likelihood technique to identify the unknown time delays, plant parameters, and noise covariances of linear discrete stochastic systems is presented. Cases of additive white noise and colored measurement noises are considered. The likelihood function is evaluated using either a minimum-variance (Kalman) filter or a minimal-order observer. The Kalman filter is used in the identification algorithm to provide minimum-variance estimates. The minimal-order observer is a lower-dimensional and computationally simpler filter, and is advantageous especially for systems with long delays. It provides a less optimal solution to the minimum-mean-square state estimation problem. The colored-noise observer algorithm has the disadvantage of having to compute an extra error covariance matrix of lower order.

Wong, E. C.↗

New definitions of pointing stability - ac and dc effects

For most imaging sensors, a constant (dc) pointing error is unimportant (unless large), but time-dependent (ac) errors degrade performance by either distorting or smearing the image. When properly quantified, the separation of the root-mean-square effects of random line-of-sight motions into dc and ac components can be used to obtain the minimum necessary line-of-sight stability specifications. The relation between stability requirements and sensor resolution is discussed, with a view to improving communication between the data analyst and the control systems engineer.

Lucke, Robert L.↗

A comparison of past and present computational methods for shape analysis of double-shell x-ray radiographs

Implosion symmetry is a key requirement in achieving a robust burning plasma in inertial confinement fusion experiments. In double-shell capsule implosions, we are interested in the shape of the inner shell as it pushes on the fuel. Shape analysis is a popular technique for studying said symmetry during implosion. Combinations of filtering and contour-finding algorithms are studied for their promise in reliably recovering Legendre shape coefficients from synthetic radiographs of double-shell capsules with applied levels of noise. A radial lineout max(slope) method when used on an image pre-filtered with non-local means and a variant of the marching squares algorithm are able to recover p 0 , p 2 , and p 4 maxslope Legendre shape coefficients with mean pixel discrepancy errors of 2.81 and 3.06, respectively, for the noisy synthetic radiographs we consider. Here, this improves upon prior radial lineout methods paired with Gaussian filtering, which we show to be unreliable and whose performance is dependent on input parameters that are difficult to estimate.

47 OTHER INSTRUMENTATION↗

SU-E-J-87: Lung Deformable Image Registration Using Surface Mesh Deformation for Dose Distribution Combination

Purpose: To allow a reliable deformable image registration (DIR) method for dose calculation in radiation therapy. This work proposes a performance assessment of a morphological segmentation algorithm that generates a deformation field from lung surface displacements with 4DCT datasets. Methods: From the 4DCT scans of 15 selected patients, the deep exhale phase of the breathing cycle is identified as the reference scan. Varian TPS EclipseTM is used to draw lung contours, which are given as input to the morphological segmentation algorithm. Voxelized contours are smoothed by a Gaussian filter and then transformed into a surface mesh representation. Such mesh is adapted by rigid and elastic deformations to match each subsequent lung volumes. The segmentation efficiency is assessed by comparing the segmented lung contour and the TPS contour considering two volume metrics, defined as Volumetric Overlap Error (VOE) [%] and Relative Volume Difference (RVD) [%] and three surface metrics, defined as Average Symmetric Surface Distance (ASSD) [mm], Root Mean Square Symmetric Surface Distance (RMSSD) [mm] and Maximum Symmetric Surface Distance (MSSD) [mm]. Then, the surface deformation between two breathing phases is determined by the displacement of corresponding vertices in each deformed surface. The lung surface deformation is linearly propagated in the lung volume to generate 3D deformation fields for each breathing phase. Results: The metrics were averaged over the 15 patients and calculated with the same segmentation parameters. The volume metrics obtained are a VOE of 5.2% and a RVD of 2.6%. The surface metrics computed are an ASSD of 0.5 mm, a RMSSD of 0.8 mm and a MSSD of 6.9 mm. Conclusion: This study shows that the morphological segmentation algorithm can provide an automatic method to capture an organ motion from 4DCT scans and translate it into a volume deformation grid needed by DIR method for dose distribution combination.

60 APPLIED LIFE SCIENCES↗

Advanced spacecraft tracking techniques using the Tracking and Data Relay Satellite System /TDRSS/

The TDRSS will consist initially of two geosynchronous satellites and a common ground station at White Sands, New Mexico. According to current schedules, operations are to begin in November 1980. The overall TDRSS will provide high and low bit-rate telemetry, commands, and satellite-to-satellite tracking services. Each Tracking and Data Relay Satellite (TDRS) will have four antenna systems for NASA use. The common ground station at White Sands will have three 18-meter K-band antennas. The tracking equipment at the ground station is required to meet the following specifications: (1) 0.1-radian root-mean-square (rms) phase noise on nondestruct Doppler measurements; (2) 10-nanosecond rms range noise; (3) 50-nanosecond maximum systematic range error. Attention is given to two-way range and Doppler measurements, the bilateration tracking of TDRS, and an experiment using differenced one-way Doppler measurements.

Teles, J.↗

UNAERO: A package of FORTRAN subroutines for approximating unsteady aerodynamics in the time domain

This report serves as an instruction and maintenance manual for a collection of CDC CYBER FORTRAN IV subroutines for approximating the unsteady aerodynamic forces in the time domain. The result is a set of constant-coefficient first-order differential equations that approximate the dynamics of the vehicle. Provisions are included for adjusting the number of modes used for calculating the approximations so that an accurate approximation is generated. The number of data points at different values of reduced frequency can also be varied to adjust the accuracy of the approximation over the reduced-frequency range. The denominator coefficients of the approximation may be calculated by means of a gradient method or a least-squares approximation technique. Both the approximation methods use weights on the residual error. A new set of system equations, at a different dynamic pressure, can be generated without the approximations being recalculated.

Dunn, H. J.↗

A preliminary tidal analysis of TOPEX/POSEIDON altimetry

Approximately 12 months of data from the TOPEX/POSEIDON satellite altimeter mission are analyzed for the major short-period oceanic tides. A harmonic analysis is performed on data captured within bins defined on a deep-ocean grid, which, owing to tidal aliasing considerations, must have a relatively coarse spatial resolution. Our analysis is in terms of corrections to the Schwiderski and Cartwright-Ray models, and it confirms many of the Schwiderski differences previously reported by Cartwright and Ray. Our differences with respect to the Geosat-based Cartwright and Ray model form a sectorial pattern in M(sub 2) with high/low differences separated roughly 180 deg in longitude. We suggest that these sectorial errors were most likely induced by Geosat's relatively large orbit error. Comparisons to independent data validate the improved TOPEX/POSEIDON solutions; in-situ 'ground truth' shows M(sub 2) root mean square (RMS) differences of 4.10 cm (Schwiderski), 3.86 cm (cartwright and Ray), 2.63 cm (this paper). Global rates of energy dissipation confirm earlier estimates for M(sub 2), and show improved agreement with satellite tracking studies for K(sub 1) and S(sub 2). These preliminary exercises confirm that TOPEX/POSEIDON should results in a new generation of improved global tidal models.

Schrama, E. J. O.↗

TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

60 APPLIED LIFE SCIENCES↗

Mean sea surface and geoid gradient comparisons with TOPEX altimeter data

Cycles 4 to 54 of TOPEX data have been analyzed through comparisons with the mean sea surface given on the disturbed geophysical data record (GDR). Two inverted barometer correction procedures were considered for the data reduction. One used a constant atmospheric pressure for all data while the one adopted for use, for most computations, introduced a cycle average pressure. The maximum difference between the two estimates was 3.0 cm with a clear annual signal. With the modified correction the TOPEX sea surface was compared to The Ohio State University (OSU) mean sea surface, given on the GDR, to estimate three translations ( delta x = -2.3 cm; delta y = 25.0 cm; delta z = -0.3 cm) and a bias (43.3 cm) between the two surfaces. The only significant translation is delta y which indicates the reference frame of the TOPEX system differs from that used in the OSU mean sea surface system. The bias between the TOPEX mean sea surface and the OSU mean sea surface was used to estimate an equatorial radius of 6,378,136.55 m based on an 18-cm biased estimate of the TOPEX altimeter. Examination of the average difference, by cycle, between the TOPEX sea surface and the OSU mean sea surface suggested a bias change of 3.1 +/- 2.2 mm/yr with a positive sign indicating the average ocean surface is rising or the altimeter measured distance is decreasing. Models were implemented that solved directly for a bias, bias rate annual/semiannual, and tide correction terms. The computations indicated that a simultaneous solution for this bias, bias rate, and annual/semiannual terms gave the most accurate results. Nonsimultaneous solutions led to slightly different bias rate values. The root mean square difference between the TOPEX sea surface and OSU sea surface, after translation and bias correction, was +/- 17 cm for a typical cycle. Some locations were indentified where the difference could reach 2.3 cm and were repeated over several cycles indicating errors in the mean sea surface. Most of the large differences occur in regions lacking altimeter data prior to the TOPEX/POSEIDON mission and/or areas of significant bathymetric signature. Geoid gradients are needed for the reduction of individual track data to a reference track. The accuracy of the determination of such gradients was determined through the comparison of predicted along-track gradients to the observed gradients. Among four mean sea surfaces tested the best agreement was found with the OSU mean sea surface placed on the TOPEX geophysical data record.

Rapp, Richard H.↗

Control theory for random systems

A survey is presented of the current knowledge available for designing and predicting the effectiveness of controllers for dynamic systems which can be modeled by ordinary differential equations. A short discussion of feedback control is followed by a description of deterministic controller design and the concept of system state. The need for more realistic disturbance models led to the use of stochastic process concepts, in particular the Gauss-Markov process. A compensator controlled system, with random forcing functions, random errors in the measurements, and random initial conditions, is treated as constituting a Gauss-Markov random process; hence the mean-square behavior of the controlled system is readily predicted. As an example, a compensator is designed for a helicopter to maintain it in hover in a gusty wind over a point on the ground.

Bryson, A. E., Jr.↗

Error analysis of marker-based object localization using a single-plane XRII

The role of imaging and image guidance is increasing in surgery and therapy, including treatment planning and follow-up. Fluoroscopy is used for two-dimensional (2D) guidance or localization; however, many procedures would benefit from three-dimensional (3D) guidance or localization. Three-dimensional computed tomography (CT) using a C-arm mounted x-ray image intensifier (XRII) can provide high-quality 3D images; however, patient dose and the required acquisition time restrict the number of 3D images that can be obtained. C-arm based 3D CT is therefore limited in applications for x-ray based image guidance or dynamic evaluations. 2D-3D model-based registration, using a single-plane 2D digital radiographic system, does allow for rapid 3D localization. It is our goal to investigate - over a clinically practical range - the impact of x-ray exposure on the resulting range of 3D localization precision. In this paper it is assumed that the tracked instrument incorporates a rigidly attached 3D object with a known configuration of markers. A 2D image is obtained by a digital fluoroscopic x-ray system and corrected for XRII distortions ({+-}0.035 mm) and mechanical C-arm shift ({+-}0.080 mm). A least-square projection-Procrustes analysis is then used to calculate the 3D position using the measured 2D marker locations. The effect of x-ray exposure on the precision of 2D marker localization and on 3D object localization was investigated using numerical simulations and x-ray experiments. The results show a nearly linear relationship between 2D marker localization precision and the 3D localization precision. However, a significant amplification of error, nonuniformly distributed among the three major axes, occurs, and that is demonstrated. To obtain a 3D localization error of less than {+-}1.0 mm for an object with 20 mm marker spacing, the 2D localization precision must be better than {+-}0.07 mm. This requirement was met for all investigated nominal x-ray exposures at 28 cm FOV, and for all but the lowest two at 40 cm FOV. However, even for those two nominal exposures, the expected 3D localization error is less than {+-}1.2 mm. The tracking precision was {+-}0.65 mm for the out-of-plane translations, {+-}0.05 mm for in-plane translations, and {+-}0.05 deg. for the rotations. The root mean square (RMS) difference between the true and projection-Procrustes calculated location was 1.07 mm. It is believed these results show the potential of this technique for dynamic evaluations or real-time image guidance using a single x-ray source and XRII detector.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Semiautomatic segmentation of aortic valve from sequenced ultrasound image using a novel shape-constraint GCV model

Purpose: Effective and accurate segmentation of the aortic valve (AV) from sequenced ultrasound (US) images remains a technical challenge because of intrinsic factors of ultrasound images that impact the quality and the continuous changes of shape and position of segmented objects. In this paper, a novel shape-constraint gradient Chan-Vese (GCV) model is proposed for segmenting the AV from time serial echocardiography. Methods: The GCV model is derived by incorporating the energy of the gradient vector flow into a CV model framework, where the gradient vector energy term is introduced by calculating the deviation angle between the inward normal force of the evolution contour and the gradient vector force. The flow force enlarges the capture range and enhances the blurred boundaries of objects. This is achieved by adding a circle-like contour (constructed using the AV structure region as a constraint shape) as an energy item to the GCV model through the shape comparison function. This shape-constrained energy can enhance the image constraint force by effectively connecting separate gaps of the object edge as well as driving the evolution contour to quickly approach the ideal object. Because of the slight movement of the AV in adjacent frames, the initial constraint shape is defined by users, with the other constraint shapes being derived from the segmentation results of adjacent sequence frames after morphological filtering. The AV is segmented from the US images by minimizing the proposed energy function. Results: To evaluate the performance of the proposed method, five assessment parameters were used to compare it with manual delineations performed by radiologists (gold standards). Three hundred and fifteen images acquired from nine groups were analyzed in the experiment. The area-metric overlap error rate was 6.89% ± 2.88%, the relative area difference rate 3.94% ± 2.63%, the average symmetric contour distance 1.08 ± 0.43 mm, the root mean square symmetric contour distance 1.37 ± 0.52 mm, and the maximum symmetric contour distance was 3.57 ± 1.72 mm. Conclusions: Compared with the CV model, as a result of the combination of the gradient vector and neighborhood shape information, this semiautomatic segmentation method significantly improves the accuracy and robustness of AV segmentation, making it feasible for improved segmentation of aortic valves from US images that have fuzzy boundaries.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of surface and satellite gravity data

Satellite derived potential coefficients (GEM 9) are compared to terrestrial gravity data by degree in terms of coefficient differences and in terms of mean anomaly differences. The root mean square undulation difference (to degree 20) was 9 + or - m and the anomaly difference was + or - 7 mgals with GEM 9 commission errors of + or - 1.7 m and + or - 3.8 mgals. The standard deviations of the GEM 9 implied undulations increased from + or - 4 cm at degree 2 to + or - 53 cm at degree 20. The corresponding values implied by a recent (June 1978) terrestrial 5 deg field were + or - 2.53 m and + or - 0.38 m (at degree 20). Comparisons between Geos-3 altimeter derived anomalies and 1 deg X 1 Deg terrestrial data showed that + or - 6-8 mgals is a reasonable accuracy estimate for the altimeter derived anomalies. Anomalies derived from satellite to satellite tracking data indicate an accuracy of about + or - 6 mgals for the recovery of 5 deg equal area blocks.

Rapp, R. H.↗

Design of adaptive control systems by means of self-adjusting transversal filters

The design of closed-loop adaptive control systems based on nonparametric identification was addressed. Implementation is by self-adjusting Least Mean Square (LMS) transversal filters. The design concept is Model Reference Adaptive Control (MRAC). Major issues are to preserve the linearity of the error equations of each LMS filter, and to prevent estimation bias that is due to process or measurement noise, thus providing necessary conditions for the convergence and stability of the control system. The controlled element is assumed to be asymptotically stable and minimum phase. Because of the nonparametric Finite Impulse Response (FIR) estimates provided by the LMS filters, a-priori information on the plant model is needed only in broad terms. Following a survey of control system configurations and filter design considerations, system implementation is shown here in Single Input Single Output (SISO) format which is readily extendable to multivariable forms. In extensive computer simulation studies the controlled element is represented by a second-order system with widely varying damping, natural frequency, and relative degree.

Merhav, S. J.↗

Uncertainty Quantification of GEOS-5 L-band Radiative Transfer Model Parameters Using Bayesian Inference and SMOS Observations

Uncertainties in L-band (1.4 GHz) radiative transfer modeling (RTM) affect the simulation of brightness temperatures (Tb) over land and the inversion of satellite-observed Tb into soil moisture retrievals. In particular, accurate estimates of the microwave soil roughness, vegetation opacity and scattering albedo for large-scale applications are difficult to obtain from field studies and often lack an uncertainty estimate. Here, a Markov Chain Monte Carlo (MCMC) simulation method is used to determine satellite-scale estimates of RTM parameters and their posterior uncertainty by minimizing the misfit between long-term averages and standard deviations of simulated and observed Tb at a range of incidence angles, at horizontal and vertical polarization, and for morning and evening overpasses. Tb simulations are generated with the Goddard Earth Observing System (GEOS-5) and confronted with Tb observations from the Soil Moisture Ocean Salinity (SMOS) mission. The MCMC algorithm suggests that the relative uncertainty of the RTM parameter estimates is typically less than 25 of the maximum a posteriori density (MAP) parameter value. Furthermore, the actual root-mean-square-differences in long-term Tb averages and standard deviations are found consistent with the respective estimated total simulation and observation error standard deviations of m3.1K and s2.4K. It is also shown that the MAP parameter values estimated through MCMC simulation are in close agreement with those obtained with Particle Swarm Optimization (PSO).

MCMC↗