Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Prostate Intrafraction Motion Assessed by Simultaneous Kilovoltage Fluoroscopy at Megavoltage Delivery I: Clinical Observations and Pattern Analysis

Purpose: To describe prostate intrafraction motion using kilovoltage fluoroscopy at treatment delivery for a hypofractionated radiotherapy protocol. Methods and Materials: Kilovoltage images were acquired during treatment delivery, as well as pre- and posttreatment cone-beam computed tomography (CBCT) for each fraction of 30 patients, totaling 571 fractions for analysis. We calculated population statistics, evaluated correlation between interfraction and intrafraction motion, evaluated effect of treatment duration, classified whether motion resolved by posttreatment CBCT, and compared motion magnitude on a per-patient basis. Results: The elapsed time between pre- and post-CBCTs was (18.6 {+-} 4.5) min. The population mean of motion measured by kilovoltage fluoroscopy was (-0.1, 0.5, -0.6) mm, the systematic was (0.5, 1.3, 1.2) mm, and random was (0.9, 1.9, 2.0) mm in the right-left, anterior-posterior, and superior-inferior axes, respectively. The probability of motion increased with treatment duration, with the mean increasing to (0.0, 1.0, -0.9) mm and the systematic to (0.6, 1.7, 1.5) mm when measured using posttreatment CBCT. For any motion {>=}2mm, approximately 75% did not resolve by posttreatment CBCT. Motion magnitude varied considerably among patients, with the probability of a 5-mm displacement ranging from 0.0% to 58.8%. Conclusions: Time dependency of intrafraction motion should be considered to avoid bias in margin assessment, with posttreatment CBCT slightly exaggerating the true motion. The patient-specific nature of the intrafraction motion suggests that a patient-specific management approach may be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nano Pattern on n-Si (100) Surface by Ion Irradiation

Nano structuring of silicon surface by low energy ion irradiation is reported. Semi insulating n-Si (100) has been irradiated by 50 keV Ar{sup +} ion beam at an angle of 50 deg. with respect to surface normal. The irradiated sample's surfaces were analyzed by Atomic Force Microscopy. Irradiation caused formation of nano-sized elliptical dots aligned in rows perpendicular to ion beam direction at fluence of 1x10{sup 17} ions/cm{sup 2}. At higher fluences of 3x10{sup 17} ions/cm{sup 2} and 7x10{sup 17} ions/cm{sup 2} self organized ripples were developed on the surface.

36 MATERIALS SCIENCE↗

200 MeV Ag{sup 15+} ion beam irradiation effects on spray deposited 5 wt% 'Li' doped V{sub 2}O{sub 5} thin film

Lithium 5 wt% doped V{sub 2}O{sub 5} thin film was deposited onto ITO substrate by spray pyrolysis technique. The substrate temperature was kept at 450 °C. 200 MeV Ag{sup 15+} ion beams at a fluence of 5×10{sup 12} ions/cm{sup 2} was irradiated on 5 wt% ‘Li’ doped V{sub 2}O{sub 5} film of thickness 1367 nm. The XRD pattern confirms that the pristine film is non stoichiometry with orthorhombic structure and upon irradiation the crystallinity decreased and an obvious textured growth along (020) plane is induced. Raman peak observed at 917 cm{sup −1} is due to oxygen deficiency. Upon irradiation, the optical transparency and band gap of the film decreased. Electrical transport property study shows that the resistivity increased by one order for the irradiated film.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New developments in web based monitoring at the CMS experiment

The rate of performance improvements of the LHC at CERN has had a strong influence on the characteristics of the monitoring tools developed for the experiments. We present some of the latest additions to the suite of Web Based Monitoring services for the CMS experiment, and explore the aspects that address the roughly 20-fold increase in peak instantaneous luminosity over the course of 2011. One of these user-friendly tools allows collaborators to easily view, and make correlations among, accelerator configuration information such as bunch patterns, measured quantities such as intensities, vacuum pressures, and background conditions, as well as derived quantities such as luminosity and the number of simultaneous interactions per beam crossing. An additional tool summarizes the daily, weekly, and yearly luminosity and efficiency. Finally, we discuss a trigger cross section and rate fitting service that uses data from previous runs to validate current running conditions, as well as to serve as a predictive extrapolation tool for developing triggers for higher luminosity running.

Badgett, William↗

SU-F-T-436: A Method to Evaluate Dosimetric Properties of SFGRT in Eclipse TPS

Purpose: The objective was to develop a method for dose distribution calculation of spatially-fractionated-GRID-radiotherapy (SFGRT) in Eclipse treatment-planning-system (TPS). Methods: Patient treatment-plans with SFGRT for bulky tumors were generated in Varian Eclipse version11. A virtual structure based on the GRID pattern was created and registered to a patient CT image dataset. The virtual GRID structure was positioned on the iso-center level together with matching beam geometries to simulate a commercially available GRID block made of brass. This method overcame the difficulty in treatment-planning and dose-calculation due to the lack o-the option to insert a GRID block add-on in Eclipse TPS. The patient treatment-planning displayed GRID effects on the target, critical structures, and dose distribution. The dose calculations were compared to the measurement results in phantom. Results: The GRID block structure was created to follow the beam divergence to the patient CT images. The inserted virtual GRID block made it possible to calculate the dose distributions and profiles at various depths in Eclipse. The virtual GRID block was added as an option to TPS. The 3D representation of the isodose distribution of the spatially-fractionated beam was generated in axial, coronal, and sagittal planes. Physics of GRID can be different from that for fields shaped by regular blocks because the charge-particle-equilibrium cannot be guaranteed for small field openings. Output factor (OF) measurement was required to calculate the MU to deliver the prescribed dose. The calculated OF based on the virtual GRID agreed well with the measured OF in phantom. Conclusion: The method to create the virtual GRID block has been proposed for the first time in Eclipse TPS. The dosedistributions, in-plane and cross-plane profiles in PTV can be displayed in 3D-space. The calculated OF’s based on the virtual GRID model compare well to the measured OF’s for SFGRT clinical use.

60 APPLIED LIFE SCIENCES↗

Plasmonic Control of Radiation and Absorption Processes in Semiconductor Quantum Dots

This document reviews a research program funded by the DOE Office of Science, which has been focused on the control of radiation and absorption processes in semiconductor photonic materials (including III-nitride quantum wells and quantum dots), through the use of specially designed metallic nanoparticles (NPs). By virtue of their strongly confined plasmonic resonances (i.e., collective oscillations of the electron gas), these nanostructures can concentrate incident radiation into sub-wavelength “hot spots” of highly enhanced field intensity, thereby increasing optical absorption by suitably positioned absorbers. By reciprocity, the same NPs can also dramatically increase the spontaneous emission rate of radiating dipoles located within their hot spots. The NPs can therefore be used as optical antennas to enhance the radiation output of the underlying active material and at the same time control the far-field pattern of the emitted light. The key accomplishments of the project include the demonstration of highly enhanced light emission efficiency as well as plasmonic collimation and beaming along geometrically tunable directions, using a variety of plasmonic excitations. Initial results showing the reverse functionality (i.e., plasmonic unidirectional absorption and photodetection) have also been generated with similar systems. Furthermore, a new paradigm for the near-field control of light emission has been introduced through rigorous theoretical studies, based on the use of gradient metasurfaces (i.e., optical nanoantenna arrays with spatially varying shape, size, and/or orientation). These activities have been complemented by materials development efforts aimed at the synthesis of suitable light-emitting samples by molecular beam epitaxy. In the course of these efforts, a novel technique for the growth of III-nitride quantum dots has also been developed (droplet heteroepitaxy), with several potential advantages in terms of compositional and geometrical control. The results of these studies provide fundamental new understanding of optical processes at the nanoscale, including near-field energy transfer between quantum emitters and photonic nanostructures, dissipation phenomena of plasmonic excitations, and radiation from nanoantennas. Furthermore, they may open the way to entirely new device concepts and applications, in a broad range of disciplines including optoelectronics, sensing, spectroscopy, photovoltaics, and quantum information science. A specific application of particularly strong relevance to the DOE mission is the development of energy efficient LED active materials for solid-state lighting, based on plasmonic enhancement effects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasi-static shape estimation and control of adaptive truss structures

Methods for estimating the deformation of adaptive truss structures are proposed which employ internal displacement sensors to measure changes in the length of selected truss members. Based on the measured data from the instrumented truss member, the total truss deformation pattern can be estimated through direct interpolation. To verify the validity of the methods presented here, numerical simulations are carried out for simple plane trusses, a beam truss, and a tetrahedral truss.

Kuwao, Fumihiro↗

Broadband Venetian-Blind Polarizer With Dual Vanes

Improved venetian-blind polarizer features optimized tandem, two-layer vane configuration reducing undesired reflections and deformation of radiation pattern below those of prior single-layer vane configuration. Consists of number of thin, parallel metal strips placed in path of propagating radio-frequency beam. Offers simple way to convert polarization from linear to circular or from circular to linear. Particularly useful for beam-wave-guide applications.

Conroy, Bruce L.↗

Simultaneous in situ Optical Monitoring Techniques during Crystal Growth of ZnSe by Physical Vapor Transport

ZnSe crystals grown in sealed ampoules by the physical vapor transport method were monitored in situ using three techniques, simultaneously. A Michelson interferometer was set-up to observe the growth rate and surface morphological evolution. An interference pattern (interferogram) is formed by the interaction between the reflection of a HeNe laser (632.8 nm wavelength) off the crystal-vapor interface and a reference beam from the same laser. Preliminary results indicate that the rate of growth/thermal-etching can be calculated using analog data acquisition and simple fringe counting techniques. Gross surface features may also be observed using a digital frame grabber and fringe analysis software. The second in situ technique uses optical absorption to determine the partial pressures of the vapor species. The Se2 and Zn vapor species present in the sealed ampoule absorb light at characteristic wavelengths. The optical absorption is determined by monitoring the light intensity difference between the sample and reference beams. The Se2 Partial pressure profile along the length of the ampoule was estimated from the vibronic absorption peaks at 340.5, 350.8, 361.3 and 379.2 nm using the Beer's law constants established in the calibration runs of pure Se. Finally, because the high temperature crystal growth furnace contains windows, in situ visual observation of the growing crystal is also possible. The use of these techniques not only permits in situ investigation of high temperature vapor growth of semiconductors, but also offers the potential for real time feed back on the growing crystal and allows the possibility of actively controlling the growth process.

Su, C.- H.↗

A Low Loss Microstrip Antenna for Radiometric Applications

The design and analysis of a series-fed, low-loss, inverted microstrip array antenna, operating at 1.413 GHz is presented. The antenna is composed of two subarrays. Each subarray consists of an equal number of microstrip patches all connected together with microstrip lines. In the first design microstrip array for linear polarization is presented which incorporated a series feeding technique. The next design, which is capable of dual linear polarization (V-polarization and H-polarization), utilizes a corporate feed network for the V-pol and series feed arrangement for the H-pol. The first element of each subarray for H-pol is coaxially fed with a 180 deg phase difference. This approach ensures a symmetric radiation pattern on broadside in H-pol. For the V-pol two feeds are in the same phase on the two subarrays ensuring a broadside beam in V-pol. The designs presented here are simulated using the IE3D code that utilizes the method of moments. Measured results are compared with simulated results and show good agreement.

Wahid, Parveen↗

Active Array Measurements using the Portable Laser Guided Robotic Metrology System

In this paper, we will discuss the impact of mounting structures on the installed performance of phased arrays. In particular, performance data for the Conformal, Lightweight Antennas for Aeronautical Communications Technology (CLAS-ACT) antenna will be presented. Performance data from a series of mounting configurations will show that null depth and location is particularly susceptible while the main beam steering angle remain relatively stable. In addition, the Portable Laser Guided Robotic antenna range (PLGR) will be discussed as a suitable instrument for measuring antenna patterns in complex or difficult locations that are challenging for traditional ranges. The PLGR antenna range was recently developed at the National Aeronautics and Space Administration's (NASA) Glenn Research Center (GRC) and deployed to measure in situ antenna patterns.

Piasecki, Marie↗

Active Array Measurements using the Portable Laser Guided Robotic Metrology System

In this paper, we will discuss the impact of mounting structures on the installed performance of phased arrays. In particular, performance data for the Conformal, Lightweight Antennas for Aeronautical Communications Technology (CLAS-ACT) antenna will be presented. Performance data from a series of mounting configurations will show that null depth and location is particularly susceptible to change while the main beam steering angle remains relatively stable. In addition, the Portable Laser Guided Robotic Metrology (PLGRM) system will be discussed as a suitable instrument for measuring antenna patterns in complex or difficult locations that are challenging for traditional ranges. The PLGRM system was recently developed at the National Aeronautics and Space Administration's (NASA) Glenn Research Center (GRC) and deployed to measure in situ antenna patterns.

Piasecki, Marie↗

Photoluminescent nanofiber composites, methods for fabrication, and related lighting devices

A photoluminescent nanofiber composite includes a nanofiber substrate, first luminescent particles, and second luminescent particles. The first luminescent particles are supported by the nanofibers and span at least a portion of a substrate surface, as a layer on the substrate surface, or with some particles located in a bulk of the substrate, or both. The second luminescent particles are disposed on the substrate. The second luminescent particles may be disposed directly on the substrate surface or on the first luminescent particles. The second luminescent particles may be deposited in a pattern of deposition units. The first and second luminescent particles are configured for emitting light of different respective wavelengths in response to excitation by a light beam. One or more surface treatment coatings may be provided at different locations.

36 MATERIALS SCIENCE↗

Elliptical Muon Helical Cooling Channel Coils

A helical cooling channel (HCC) consisting of a pressurized gas absorber imbedded in a magnetic channel that provides solenoid, helical dipole and helical quadrupole fields has shown considerable promise in providing six-dimensional phase space reduction for muon beams. The most effective approach to implementing the desired magnetic field is a helical solenoid (HS) channel composed of short solenoid coils arranged in a helical pattern. The HS channel along with an external solenoid allows the B$_z$ and B$_{\phi}$ components along the reference orbit to be set to any desired values. To set dB$_{\phi}$/dr to the desired value for optimum focusing requires an additional variable to tune. We shall show that using elliptical shaped coils in the HS channel allows the flexibility to achieve the desired dB$_{\phi}$/dr on the reference orbit without significant change to B$_z$ and B$_{\phi}$.

43 PARTICLE ACCELERATORS↗

Range Imaging without Moving Parts

Range-imaging instruments of a type now under development are intended to generate the equivalent of three-dimensional images from measurements of the round-trip times of flight of laser pulses along known directions. These instruments could also provide information on characteristics of targets, including roughnesses and reflectivities of surfaces and optical densities of such semi-solid objects as trees and clouds. Unlike in prior range-imaging instruments based on times of flight along known directions, there would be no moving parts; aiming of the laser beams along the known directions would not be accomplished by mechanical scanning of mirrors, prisms, or other optical components. Instead, aiming would be accomplished by using solid-state devices to switch input and output beams along different fiber-optic paths. Because of the lack of moving parts, these instruments could be extraordinarily reliable, rugged, and long-lasting. An instrument of this type would include an optical transmitter that would send out a laser pulse along a chosen direction to a target. An optical receiver coaligned with the transmitter would measure the temporally varying intensity of laser light reflected from the target to determine the distance and surface characteristics of the target. The transmitter would be a combination of devices for generating precise directional laser illumination. It would include a pulsed laser, the output of which would be coupled into a fiber-optic cable with a fan-out and solid-state optical switches that would enable switching of the laser beam onto one or more optical fibers terminated at known locations in an array on a face at the focal plane of a telescope. The array would be imaged by the telescope onto the target space. The receiver optical system could share the aforementioned telescope with the transmitter or could include a separate telescope aimed in the same direction as that of the transmitting telescope. In either case, light reflected from the target would be focused by the receiver optical system onto an array of optical fibers matching the array in the transmitter. These optical fibers would couple the received light to one or more photodetector( s). Optionally, the receiver could include solid-state optical switches for choosing which optical fiber(s) would couple light to the photodetector(s). This instrument architecture is flexible and can be optimized for a wide variety of applications and levels of performance. For example, it is scalable to any number of pixels and pixel resolutions and is compatible with a variety of ranging and photodetection methodologies, including, for example, ranging by use of modulated (including pulsed and encoded) light signals. The use of fixed arrays of optical fibers to generate controlled illumination patterns would eliminate the mechanical complexity and much of the bulk of optomechanical scanning assemblies. Furthermore, digital control of the selection of the fiber-optic pathways for the transmitted beams could afford capabilities not seen in previous three-dimensional range-imaging systems. Instruments of this type could be specialized for use as, for example, proximity detectors, three-dimensional robotic vision systems, airborne terrain-mapping systems, and inspection systems.

Blair, J. Bryan↗

Laser Interferometer Space Antenna (LISA) Far Field Phase Patterns

The Laser Interferometer Space Antenna (LISA) consists of three spacecraft in orbit about the sun. The orbits are chosen such that the three spacecraft are always at (roughly) the vertices of a equilateral triangle with 5 million kilometer leg lengths. Even though the distances between the three spacecraft are 5 million kilometers, the expected phase shifts between any two beams, due to a gravitational wave, only correspond to a distance change of about 10 pico meters, which is about 10(exp -5) waves for a laser wavelength of 1064 nm. To obtain the best signal-to-noise ratio, noise sources such as changes in the apparent distances due to pointing jitter must be controlled carefully. This is the main reason for determining the far-field phase patterns of a LISA type telescope. Because of torque on the LISA spacecraft and other disturbances, continuous adjustments to the pointing of the telescopes are required. These pointing adjustments will be a "jitter" source. If the transmitted wave is perfectly spherical then rotations (Jitter) about its geometric center will not produce any effect at the receiving spacecraft. However, if the outgoing wave is not perfectly spherical, then pointing jitter will produce a phase variation at the receiving spacecraft. The following sections describe the "brute force" computational approach used to determine the scalar wave front as a function of exit pupil (Zernike) aberrations and to show the results (mostly graphically) of the computations. This approach is straightforward and produces believable phase variations to sub-pico meter accuracy over distances on the order of 5 million kilometers. As such this analyzes the far field phase sensitivity to exit pupil aberrations.

Waluschka, Eugene↗

Investigation of optical properties of epitaxial yttrium iron garnet films

In work we investigated yttrium iron garnet epitaxial films with a thickness of 10 µm and 55 µm which were grown on the surface of garnet substrate. Using the polarizing microscopy method the branching domain structure of films was shown with the period of domains 21.5 µm and 42.5 µm. Disappearance of domains at presence of an external magnetic field up to 100 Oe was noted. The optical transmission of films for the polarized beam of HeNe laser is investigated and zero diffraction order and odd diffraction rings orders were shown. Interconnection of the period of chaotically oriented domains with angles of axially symmetric diffraction rings orders was shown. Diffraction patterns at various longitudinal magnetic fields are investigated. Disappearance of odd diffraction orders and increasing in intensity of zero diffraction order were fixed. Optical transmission of epitaxial films was measured in range of 500 - 900 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simultaneous reduction of radiation dose and scatter for CBCT by using collimators

Purpose: On-board cone-beam CT (CBCT) imaging has been widely available in radiotherapy clinic for target localization. However, the extra radiation dose from CBCT is always a concern for its frequent use. Additionally, the relatively large scatter in CBCT often degrades the image quality. By using collimators, some of the X-rays can be stopped from reaching the patient and the detectors, hence both the scatter and the patient doses are simultaneously reduced. The authors show in this work that the collimated CBCT data can be reconstructed without any noticeable artifacts for certain collimator blocking ratios and blocking patterns, and the focus of this work is to study the relationship between the image quality and these two collimator factors.Methods: A CBCT system with collimators was simulated following the typical geometry used in clinic. Different collimator designs were tested by varying the size and the number of the collimator slits, and at the same time, the ratio of transmitted beams to total beams was varied from 100% to 10%, resulting in hundreds of different simulation scenarios. Lung and pelvis phantoms created from patients CT images were used in the simulations, and an iterative reconstruction algorithm using the compressed sensing technique was adopted. The image quality was examined by root mean square errors (RMSEs) and compared with the conventional CBCT images.Results: The CBCT image quality increases as the amount of beams passing through the collimators increases, and decreases as the size of the collimator slits increases. With ultra-high resolution collimators, the RMSEs were comparable to the conventional CBCT image quality until the beam transmission rate is reduced below 25%.Conclusions: Collimators can reduce the scatters and radiation dose, however, the collimated CBCT image quality is strongly dependent on both the collimator blocking ratio and the blocking pattern. To achieve image quality comparable to the conventional CBCT, the amount of information and data format must be adequate.

61 RADIATION PROTECTION AND DOSIMETRY↗