Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

SU-G-201-08: Energy Response of Thermoluminescent Microcube Dosimeters in Water for Kilovoltage X-Ray Beams

Purpose: To characterize the energy dependence for TLD-100 microcubes in water at kilovoltage energies. Methods: TLD-100 microcubes with dimensions of (1 × 1 × 1) mm{sup 3} were irradiated with kilovoltage x-rays in a custom-built thin-window liquid water phantom. The TLD-100 microcubes were held in Virtual Water™ probes and aligned at a 2 cm depth in water. Irradiations were performed using the M-series x-ray beams of energies ranging from 50-250 kVp and normalized to a {sup 60}Co beam located at the UWADCL. Simulations using the EGSnrc Monte Carlo Code System were performed to model the x-ray beams, the {sup 60}Co beam, the water phantom and the dosimeters in the phantom. The egs-chamber user code was used to tally the dose to the TLDs and the dose to water. The measurements and calculations were used to determine the intrinsic energy dependence, absorbed-dose energy dependence, and absorbed-dose sensitivity. These values were compared to TLD-100 chips with dimensions of (3.2 × 0.9 × 0.9) mm{sup 3}. Results: The measured TLD-100 microcube response per dose to water among all investigated x-ray energies had a maximum percent difference of 61% relative to {sup 60}Co. The simulated ratio of dose to water to the dose to TLD had a maximum percent difference of 29% relative to {sup 60}Co. The ratio of dose to TLD to the TLD output had a maximum percent difference of 13% relative to {sup 60}Co. The maximum percent difference for the absorbed-dose sensitivity was 15% more than the used value of 1.41. Conclusion: These results confirm that differences in beam quality have a significant effect on TLD response when irradiated in water. These results also indicated a difference in TLD-100 response between microcube and chip geometries. The intrinsic energy dependence and the absorbed-dose energy dependence deviated up to 10% between TLD-100 microcubes and chips.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-01: A Novel MRI Post-Processing Algorithm for Visualization of the Prostate LDR Brachytherapy Seeds and Calcifications Based On B0 Field Inhomogeneity Correction and Hough Transform

Purpose: This study aims at developing an MRI-only workflow for post-implant dosimetry of the prostate LDR brachytherapy seeds. The specific goal here is to develop a post-processing algorithm to produce positive contrast for the seeds and prostatic calcifications and differentiate between them on MR images. Methods: An agar-based phantom incorporating four dummy seeds (I-125) and five calcifications of different sizes (from sheep cortical bone) was constructed. Seeds were placed arbitrarily in the coronal plane. The phantom was scanned with 3T Philips Achieva MR scanner using an 8-channel head coil array. Multi-echo turbo spin echo (ME-TSE) and multi-echo gradient recalled echo (ME-GRE) sequences were acquired. Due to minimal susceptibility artifacts around seeds, ME-GRE sequence (flip angle=15; TR/TE=20/2.3/2.3; resolution=0.7×0.7×2mm3) was further processed.The induced field inhomogeneity due to the presence of titaniumencapsulated seeds was corrected using a B0 field map. B0 map was calculated using the ME-GRE sequence by calculating the phase difference at two different echo times. Initially, the product of the first echo and B0 map was calculated. The features corresponding to the seeds were then extracted in three steps: 1) the edge pixels were isolated using “Prewitt” operator; 2) the Hough transform was employed to detect ellipses approximately matching the dimensions of the seeds and 3) at the position and orientation of the detected ellipses an ellipse was drawn on the B0-corrected image. Results: The proposed B0-correction process produced positive contrast for the seeds and calcifications. The Hough transform based on Prewitt edge operator successfully identified all the seeds according to their ellipsoidal shape and dimensions in the edge image. Conclusion: The proposed post-processing algorithm successfully visualized the seeds and calcifications with positive contrast and differentiates between them according to their shapes. Further assessments on more realistic phantoms and patient study are required to validate the outcome.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-06: Estimating Relative Tissue Density From Quantitative MR Images: A Novel Perspective for MRI-Only Heterogeneity Corrected Dose Calculation

Purpose: To explore the feasibility of extracting the relative density from quantitative MRI measurements as well as estimate a correlation between the extracted measures and CT Hounsfield units. Methods: MRI has the ability to separate water and fat signals, producing two separate images for each component. By performing appropriate corrections on the separated images, quantitative measurement of water and fat mass density can be estimated. This work aims to test this hypothesis on 1.5T.Peanut oil was used as fat-representative, while agar as water-representative. Gadolinium Chloride III and Sodium Chloride were added to the agar solution to adjust the relaxation times and the medium conductivity, respectively. Peanut oil was added to the agar solution with different percentages: 0%, 3%, 5%, 10%, 20%, 30%, 40%, 50%, 60%, 70%, 80%, 90% and 100%. The phantom was scanned on 1.5T GE Optima 450W with the body coil using a multigradient echo sequences. Water/fat separation were performed while correcting for main field (B0) inhomogeneity and T{sub 2}* relaxation time. B1+ inhomogeneities were ignored. The phantom was subsequently scanned on a Philips Brilliance CT Big Bore. MR-corrected fat signal from all vials were normalized to 100% fat signal. CT Hounsfield values were then compared to those obtained from the normalized MR-corrected fat values as well as to the phantom for validation. Results: Good agreement were found between CT HU and the MR-extracted fat values (R{sup 2} = 0.98). CT HU also showed excellent agreement with the prepared fat fractions (R{sup 2}=0.99). Vials with 70%, 80%, and 90% fat percentages showed inhomogeneous distributions, however their results were included for completion. Conclusion: Quantitative MRI water/fat imaging can be potentially used to extract the relative tissue density. Further in-vivo validation are required.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-09: Evaluation of Transperineal Ultrasound Imaging as a Potential Solution for Target Tracking During Ablative Body Radiotherapy for Prostate Cancer

Purpose: Prostate SABR is emerging as a clinically viable, potentially cost effective alternative to prostate IMRT but its adoption is contingent on providing solutions for accurate tracking during beam delivery. Our goal is to evaluate the performance of the Clarity Autoscan ultrasound monitoring system for inter-fractional prostate motion tracking in both phantoms and in-vivo. Methods: In-vivo evaluation was performed under IRB protocol to allow data collection in prostate patients treated with VMAT whereby prostate was imaged through the acoustic window of the perineum. The probe was placed before KV imaging and real-time tracking was started and continued until the end of treatment. Initial absolute 3D positions of fiducials were estimated from KV images. Fiducial positions in MV images subsequently acquired during beam delivery were compared with predicted positions based on Clarity estimated motion. Results: Phantom studies with motion amplitudes of ±1.5, ±3, ±6 mm in lateral direction and ±2 mm in longitudinal direction resulted in tracking errors of −0.03 ± 0.3, −0.04 ± 0.6, −0.2 ± 0.9 mm, respectively, in lateral direction and −0.05 ± 0.30 mm in longitudinal direction. In phantom, measured and predicted fiducial positions in MV images were within 0.1 ± 0.6 mm. Four patients consented to participate in the study and data was acquired over a total of 140 fractions. MV imaging tracking was possible in about 75% of the time (due to occlusion of fiducials) compared to 100% with Clarity. Overall range of estimated motion by Clarity was 0 to 4.0 mm. In-vivo fiducial localization error was 1.2 ± 1.0 mm compared to 1.8 ± 1.9 mm if not taking Clarity estimated motion into account. Conclusion: Real-time transperineal ultrasound tracking reduces uncertainty in prostate position due to intrafractional motion. Research was supported by Elekta.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-05: Effect of Localizer Type and Patient Off-Centering On CT Radiation Dose with Use of Automatic Tube Current Modulation

Purpose: Apparent patient size in CT localizers varies with localizer type and patient positioning, resulting in variation in effective mAs as guided by Tube Current Modulation (TCM). Our aim was to investigate the effects of vertical off-centering on CTDI-vol when using different localizer types and TCM strengths. Methods: A CTDI body phantom was scanned using an abdominal protocol with three TCM strengths (Siemens Definition AS40, CAREDose4D; very weak, average, very strong). Data was acquired at 11 table height positions; with phantom center at isocenter and at 10 other positions between 142mm below and 53mm above. At each position, scans were acquired using 5 different localizer types: PA, AP, Lateral, PA+Lateral, and Lateral+PA. CTDI-vol was recorded for the 165 combinations of table height, localizer type, and TCM strength, and magnification factors measured from localizer images. Results: Magnification factors from AP and PA localizers ranged from 0.79–1.11 and 1.35–0.91, respectively from lowest to highest positions (highest with phantom located closest to X-ray tube), with a smaller impact when using Lateral, PA+Lateral, Lateral+PA localizer types, all of which behaved similarly. For an average TCM strength and PA localizer, CTDI-vol ranged from 75% higher to 12% lower than the isocenter value for the lowest to highest table positions, respectively. For table positions ranging from lowest to highest, CTDI-vol ranged from −23% to 17% for AP, from −8% to 0.3% for lateral and from −7% to 1% for a combination of PA and Lateral in either order. Similar behavior was found for different TCM strengths, but effects were more pronounced for very strong compared with very weak modulation strengths. Conclusion: Patient off-centering substantially impacts radiation dose, which depends on the amount of vertical offcentering and type of the localizer used. The combination of PA and Lateral localizers is most robust against effects of patient off-centering.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP2-15: Virtual Insertion of Digital Kidney Stones Into Dual-Source, Dual- Energy CT Projection Data

Purpose: In order to investigate novel methods to more accurately estimate the mineral composition of kidney stones using dual energy CT, it is desirable to be able to combine digital stones of known composition with actual phantom and patient scan data. In this work, we developed and validated a method to insert digital kidney stones into projection data acquired on a dual-source, dual-energy CT system. Methods: Attenuation properties of stones of different mineral composition were computed using tabulated mass attenuation coefficients, the chemical formula for each stone type, and the effective beam energy at each evaluated tube potential. A previously developed method to insert lesions into x-ray CT projection data was extended to include simultaneous dual-energy CT projections acquired on a dual-source gantry (Siemens Somatom Flash). Digital stones were forward projected onto both detectors and the resulting projections added to the physically acquired sinogram data. To validate the accuracy of the technique, digital stones were inserted into different locations in the ACR CT accreditation phantom; low and high contrast resolution, CT number accuracy and noise properties were compared before and after stone insertion. The procedure was repeated for two dual-energy tube potential pairs in clinical use on the scanner, 80/Sn140 kV and 100/Sn140 kV, respectively. Results: The images reconstructed after the insertion of digital kidney stones were consistent with the images reconstructed from the scanner. The largest average CT number difference for the 4 insert in the CT number accuracy module of the phantom was 3 HU. Conclusion: A framework was developed and validated for the creation of digital kidney stones of known mineral composition, and their projection-domain insertion into commercial dual-source, dual-energy CT projection data. This will allow a systematic investigation of the impact of scan and reconstruction parameters on stone attenuation and dual-energy behavior under rigorously controlled conditions. Dr. McCollough receives research support from Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-05: Development of a Thimble Calorimeter for Absorbed Dose to Water Characterized in MV Photons

Purpose: To develop a thimble sized polystyrene calorimeter for use from kV to MV photons, as a primary reference standard for applications from diagnostic CT imaging to therapy beam dose determination. Methods: A polystyrene calorimeter about 1.5 cm diameter embedded with small thermistors was characterized in a 6 MV photon beam from a clinical accelerator at 5 nominal dose rates from 0.8 to 4 Gy/min. Irradiations were delivered with beam on/off cycles first at 60 s and then at 20 s. Two sets of phantom conditions were evaluated: 1) in a 30 cm diameter polyethylene cylinder, and 2) in 10 cm depth of a 30 cm water phantom. The temperature waveforms were recorded and analyzed for temperature rise, arriving at a dose to polystyrene. This value is compared with the result of measurements under identical conditions using an ionization chamber calibrated for absorbed dose to water. Monte Carlo simulations were performed on the measurement systems to estimate such a ratio. Results: The ratio of the dose determined by the calorimeter to the dose reported by the ionization chamber was aggregated from all 5 dose rates. The 60 s results show a much elevated response in both phantoms compared to their respective expected results based on simulation. This deviation was reduced when the on/off cycles were shortened to 20 s. This behavior was possibly due to the heat conduction effects in the small calorimeter body. Finite element modeling is being conducted to simulate this effect. Conclusion: A small solid plastic calorimeter offers the convenience of a portable absorbed dose standard based on direct measurement of energy deposition, but comes at the expense of heat transfer complications which need to be characterized. This work offers preliminary evidence of the behavior and quantitative assessment of the issues to be resolved in future investigations.

60 APPLIED LIFE SCIENCES↗

SU-G-TeP2-09: Evaluation of the MaxFOV Extended Field of View (EFOV) Reconstruction Algorithm On a GE RT590 CT Scanner

Purpose: This study compares the newly released MaxFOV Revision 1 EFOV reconstruction algorithm for GE RT590 to the older WideView EFOV algorithm. Two radiotherapy overlays from Q-fix and Diacor, are included in our analysis. Hounsfield Units (HU) generated with the WideView algorithm varied in the extended field (beyond 50cm) and the scanned object’s border varied from slice to slice. A validation of HU consistency between the two reconstruction algorithms is performed. Methods: A CatPhan 504 and CIRS062 Electron Density Phantom were scanned on a GE RT590 CT-Simulator. The phantoms were positioned in multiple locations within the scan field of view so some of the density plugs were outside the 50cm reconstruction circle. Images were reconstructed using both the WideView and MaxFOV algorithms. The HU for each scan were characterized both in average over a volume and in profile. Results: HU values are consistent between the two algorithms. Low-density material will have a slight increase in HU value and high-density material will have a slight decrease in HU value as the distance from the sweet spot increases. Border inconsistencies and shading artifacts are still present with the MaxFOV reconstruction on the Q-fix overlay but not the Diacor overlay (It should be noted that the Q-fix overlay is not currently GE-certified). HU values for water outside the 50cm FOV are within 40HU of reconstructions at the sweet spot of the scanner. CatPhan HU profiles show improvement with the MaxFOV algorithm as it approaches the scanner edge. Conclusion: The new MaxFOV algorithm improves the contour border for objects outside of the standard FOV when using a GE-approved tabletop. Air cavities outside of the standard FOV create inconsistent object borders. HU consistency is within GE specifications and the accuracy of the phantom edge improves. Further adjustments to the algorithm are being investigated by GE.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP3-04: Effective Dose Measurements in Fast Kvp Switch Dual Energy Computed Tomography

Purpose: The objective of this study was two-fold: (a) to test a new approach to approximating organ dose by using the effective energy of the combined 80kV/140kV beam in dual-energy (DE) computed tomography (CT), and (b) to derive the effective dose (ED) in the abdomen-pelvis protocol in DECT. Methods: A commercial dual energy CT scanner was employed using a fast-kV switch abdomen/pelvis protocol alternating between 80 kV and 140 kV. MOSFET detectors were used for organ dose measurements. First, an experimental validation of the dose equivalency between MOSFET and ion chamber (as a gold standard) was performed using a CTDI phantom. Second, the ED of DECT scans was measured using MOSFET detectors and an anthropomorphic phantom. For ED calculations, an abdomen/pelvis scan was used using ICRP 103 tissue weighting factors; ED was also computed using the AAPM Dose Length Product (DLP) method and compared to the MOSFET value. Results: The effective energy was determined as 42.9 kV under the combined beam from half-value layer (HVL) measurement. ED for the dual-energy scan was calculated as 16.49 ± 0.04 mSv by the MOSFET method and 14.62 mSv by the DLP method. Conclusion: Tissue dose in the center of the CTDI body phantom was 1.71 ± 0.01 cGy (ion chamber) and 1.71 ± 0.06 (MOSFET) respectively; this validated the use of effective energy method for organ dose estimation. ED from the abdomen-pelvis scan was calculated as 16.49 ± 0.04 mSv by MOSFET and 14.62 mSv by the DLP method; this suggests that the DLP method provides a reasonable approximation to the ED.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-01: A Method to Quantify Lung SBRT Target Localization Accuracy Based On Digitally Reconstructed Fluoroscopy

Purpose: To develop a methodology based on digitally-reconstructed-fluoroscopy (DRF) to quantitatively assess target localization accuracy of lung SBRT, and to evaluate using both a dynamic digital phantom and a patient dataset. Methods: For each treatment field, a 10-phase DRF is generated based on the planning 4DCT. Each frame is pre-processed with a morphological top-hat filter, and corresponding beam apertures are projected to each detector plane. A template-matching algorithm based on cross-correlation is used to detect the tumor location in each frame. Tumor motion relative beam aperture is extracted in the superior-inferior direction based on each frame’s impulse response to the template, and the mean tumor position (MTP) is calculated as the average tumor displacement. The DRF template coordinates are then transferred to the corresponding MV-cine dataset, which is retrospectively filtered as above. The treatment MTP is calculated within each field’s projection space, relative to the DRF-defined template. The field’s localization error is defined as the difference between the DRF-derived-MTP (planning) and the MV-cine-derived-MTP (delivery). A dynamic digital phantom was used to assess the algorithm’s ability to detect intra-fractional changes in patient alignment, by simulating different spatial variations in the MV-cine and calculating the corresponding change in MTP. Inter-and-intra-fractional variation, IGRT accuracy, and filtering effects were investigated on a patient dataset. Results: Phantom results demonstrated a high accuracy in detecting both translational and rotational variation. The lowest localization error of the patient dataset was achieved at each fraction’s first field (mean=0.38mm), with Fx3 demonstrating a particularly strong correlation between intra-fractional motion-caused localization error and treatment progress. Filtering significantly improved tracking visibility in both the DRF and MV-cine images. Conclusion: We have developed and evaluated a methodology to quantify lung SBRT target localization accuracy based on digitally-reconstructed-fluoroscopy. Our approach may be useful in potentially reducing treatment margins to optimize lung SBRT outcomes. R01-184173.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-08: Initial Investigations of Up-Converting Nanoparticles (UCNP) for 3D Tissue Imaging in Optical-ECT

Purpose: Near-IR absorptive up-converting nanoparticles (UCNPs) is a novel contrast for optical-ECT that allows auto-fluorescence-free 3D imaging of labeled cells in a matrix of large (∼1cm{sup 3}) unsectioned normal tissue. This has the potential to image small metastases or dormant cells that is difficult with down-converting fluorescing dyes due to auto-fluorescence. The feasibility of imaging UCNP in agarose phantoms and a mouse lung is demonstrated, aided by a 3D-printed optical-ECT stage designed to excite UCNP in a mouse lung. Methods: The UCNP, NaYF{sub 4}:Yb/Er (20/2%), studied in this work up-converts 980nm light to visible light peaking sharply at ∼540nm. To characterize the UCNP emission as a function of UCNP concentration, cylindrical 2.5%wt agarose phantoms infused with UCNP at concentrations of 25µg/mL and 50µg/mL were exposed to 1.5W 980nm laser coupled to an optical fiber. The fiber was held stably at 1cm above the stage via a custom 3D-printed stage. An optically cleared lung harvested from a BALBc mice was then injected with 100µL of 1mg/mL UCNP solution ex vivo. Tomographic imaging of the UCNP emission in lung was performed. Results: The laser beam tract is visualized within the agarose phantom. A line profile of UCNP emission at 25µg/mL versus 50µg/mL shows that increasing the UCNP concentration increases emission count. UCNPs injected into a cleared mouse lung disperse throughout the respiratory tract, allowing for visualization and 3D reconstruction. Excitation before and after UCNP injection shows the tissue exhibits no auto-fluorescence at 980nm, allowing clear view of the UCNP without any obscuring features such as conventional down-converting fluorescent tags. Conclusion: We confirm that up-conversion in tissue circumvents completely tissue auto-fluorescence, which allowed background-free 3D reconstruction of the UCNP distribution. We also confirm that raising the UCNP concentration increases emission and that UCNPs are retained in agarose samples during the optical clearing process.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-13: PET Image Noise Variability and Its Consequences for Quantifying Tumor Hypoxia

Purpose: The values in a PET image which represent activity concentrations of a radioactive tracer are influenced by a large number of parameters including patient conditions as well as image acquisition and reconstruction. This work investigates noise characteristics in PET images for various image acquisition and image reconstruction parameters. Methods: Different phantoms with homogeneous activity distributions were scanned using several acquisition parameters and reconstructed with numerous sets of reconstruction parameters. Images from six PET scanners from different vendors were analyzed and compared with respect to quantitative noise characteristics. Local noise metrics, which give rise to a threshold value defining the metric of hypoxic fraction, as well as global noise measures in terms of noise power spectra (NPS) were computed. In addition to variability due to different reconstruction parameters, spatial variability of activity distribution and its noise metrics were investigated. Patient data from clinical trials were mapped onto phantom scans to explore the impact of the scanner’s intrinsic noise variability on quantitative clinical analysis. Results: Local noise metrics showed substantial variability up to an order of magnitude for different reconstruction parameters. Investigations of corresponding NPS revealed reconstruction dependent structural noise characteristics. For the acquisition parameters, noise metrics were guided by Poisson statistics. Large spatial non-uniformity of the noise was observed in both axial and radial direction of a PET image. In addition, activity concentrations in PET images of homogeneous phantom scans showed intriguing spatial fluctuations for most scanners. The clinical metric of the hypoxic fraction was shown to be considerably influenced by the PET scanner’s spatial noise characteristics. Conclusion: We showed that a hypoxic fraction metric based on noise characteristics requires careful consideration of the various dependencies in order to justify its quantitative validity. This work may result in recommendations for harmonizing QA of PET imaging for multi-institutional clinical trials.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-14: Prostate Brachytherapy Activity Measurement and Source Localization by Using a Dual Photon Emission Computed Tomography System: A Feasibility Study

Purpose: To monitor the activity distribution and needle position during and after implantation in operating rooms. Methods: Simulation studies were conducted to assess the feasibility of measurement activity distribution and seed localization using the DuPECT system. The system consists of a LaBr3-based probe and planar detection heads, a collimation system, and a coincidence circuit. The two heads can be manipulated independently. Simplified Yb-169 brachytherapy seeds were used. A water-filled cylindrical phantom with a 40-mm diameter and 40-mm length was used to model a simplified prostate of the Asian man. Two simplified seeds were placed at a radial distance of 10 mm and tangential distance of 10 mm from the center of the phantom. The probe head was arranged perpendicular to the planar head. Results of various imaging durations were analyzed and the accuracy of the seed localization was assessed by calculating the centroid of the seed. Results: The reconstructed images indicate that the DuPECT can measure the activity distribution and locate the seeds dwelt in different positions intraoperatively. The calculated centroid on average turned out to be accurate within the pixel size of 0.5 mm. The two sources were identified when the duration is longer than 15 s. The sensitivity measured in water was merely 0.07 cps/MBq. Conclusion: Preliminary results show that the measurement of the activity distribution and seed localization are feasible using the DuPECT system intraoperatively. It indicates the DuPECT system has potential to be an approach for dose-distribution-validation. The efficacy of acvtivity distribution measurement and source localization using the DuPECT system will evaluated in more realistic phantom studies (e.g., various attenuation materials and greater number of seeds) in the future investigation.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-04: Commissioning and Acceptance Testing of Optical Surface Monitoring System On TrueBEAM STx as Per Task Group 147

Purpose: Optical Surface Monitoring system (OSMS) have been recently introduced by Varian for initial patient positioning and real-time monitoring during complex radiotherapy treatment. The purpose of this work was to implement TG 147 with OSMS. Methods: Recently we installed OSMS first of its kind in India on trueBEAM STx at our Institue. The OSMS is composed of a three cameras ceiling mounted and a Workstation. The following tests were performed to validate the system a. Calibration b. System reproducibility and drift c. Static localization displacement accuracy and d. Dynamic radiation gating delivery. The Calibration procedure consists of Daily,Monthly and MV Radiation Isocenter Calibration. The reproducibility of system was tested by monitoring the varian gating phantom test pattern for at least 120 min. Each recorded pattern was registered to the reference surface to calculate the required couch adjustment. To measure the static localization displacement accuracy of the system to detect and quantify patient shift relative to a reference image,we compared the shift detected by the surface imaging system with known couch transitions in a phantom study. The phantom was set in a motion and the radiation beam was holded by changing the threshold in the software for different clinical setups to test the dynamic radiation gating capability. Results: Daily calibration was within ±0.5 mm. The MV radiation isocentre with respect to cameras was less than 1 mm in translational axis and less than 0.5° for rotational axis. The reproducibility was found to be 0.4 mm. The maximum static displacement accuracy was 0.75 mm for the three translational axis, and less than 0.5° for rotational axis. The system was able to hold the beam with a minimum threshold of 1 mm. Conclusion: A quality assurance process has been developed as per TG 147 for the clinical implementation of an OSMS in radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP4-05: Effects of Irregular Respiratory Motion On the Positioning Accuracy of Moving Target with Free Breathing Cone-Beam Computerized Tomography

Purpose: Average or maximum intensity projection (AIP or MIP) images derived from 4DCT images are often used as a reference image for target alignment when free breathing Cone-beam CT (FBCBCT) is used for positioning a moving target at treatment. This method can be highly accurate if the patient has stable respiratory motion. However, a patient’s breathing pattern often varies irregularly. The purpose of this study is to investigate the effect of irregular respiration on the positioning accuracy of a moving target with FBCBCT. Methods: Eight patients’ respiratory motion curves were selected to drive a Quasar phantom with embedded cubic and spherical targets. A 4DCT of the moving phantom was acquired on a CT scanner (Philips Brilliance 16) equipped with a Varian RPM system. The phase binned 4DCT images and the corresponding MIP and AIP images were transferred into Eclipse for analysis. CBCTs of the phantom driven by the same breathing curves were acquired on a Varian TrueBeam and fused such that the zero positions of moving targets are the same on both CBCT and AIP images. The sphere and cube volumes and centrioid differences (alignment error) determined by MIP, AIP and FBCBCT images were compared. Results: Compared to the volume determined by FBCBCT, the volumes of cube and sphere in MIP images were 22.4%±8.8% and 34.2%±6.2% larger while the volumes in AIP images were 7.1%±6.2% and 2.7%±15.3% larger, respectively. The alignment errors for the cube and sphere with center-center matches between MIP and FBCBCT were 3.5±3.1mm and 3.2±2.3mm, and the alignment errors between AIP and FBCBCT were 2.1±2.6mm and 2.1±1.7mm, respectively. Conclusion: AIP images appear to be superior reference images than MIP images. However, irregular respiratory motions could compromise the positioning accuracy of a moving target if the target center-center match is used to align FBCBCT and AIP images.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-04: Hands-On Fluoroscopy Safety Training with Real-Time Patient and Staff Dosimetry

Purpose: Fluoroscopically guided interventions (FGI) are routinely performed across many different hospital departments. However, many involved staff members have minimal training regarding safe and optimal use of fluoroscopy systems. We developed and taught a hands-on fluoroscopy safety class incorporating real-time patient and staff dosimetry in order to promote safer and more optimal use of fluoroscopy during FGI. Methods: The hands-on fluoroscopy safety class is taught in an FGI suite, unique to each department. A patient equivalent phantom is set on the patient table with an ion chamber positioned at the x-ray beam entrance to the phantom. This provides a surrogate measure of patient entrance dose. Multiple solid state dosimeters (RaySafe i2 dosimetry systemTM) are deployed at different distances from the phantom (0.1, 1, 3 meters), which provide surrogate measures of staff dose. Instructors direct participating clinical staff to operate the fluoroscopy system as they view live fluoroscopic images, patient entrance dose, and staff doses in real-time. During class, instructors work with clinical staff to investigate how patient entrance dose, staff doses, and image quality are affected by different parameters, including pulse rate, magnification, collimation, beam angulation, imaging mode, system geometry, distance, and shielding. Results: Real-time dose visualization enables clinical staff to directly see and learn how to optimize their use of their own fluoroscopy system to minimize patient and staff dose, yet maintain sufficient image quality for FGI. As a direct result of the class, multiple hospital departments have implemented changes to their imaging protocols, including reduction of the default fluoroscopy pulse rate and increased use of collimation and lower dose fluoroscopy modes. Conclusion: Hands-on fluoroscopy safety training substantially benefits from real-time patient and staff dosimetry incorporated into the class. Real-time dose display helps clinical staff visualize, internalize, and ultimately utilize the safety techniques learned during the training. RaySafe/Unfors/Fluke lent us a portable version of their RaySafe i2 Dosimetry System for 6 months.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-08: Four-Dimensional Cone-Beam CT Iterative Reconstruction with Time-Ordered Chain Graph Model for Non-Periodic Organ Motion and Deformation

Purpose: The purpose of this study is to propose a new concept of four-dimensional (4D) cone-beam CT (CBCT) reconstruction for non-periodic organ motion using the Time-ordered Chain Graph Model (TCGM), and to compare the reconstructed results with the previously proposed methods, the total variation-based compressed sensing (TVCS) and prior-image constrained compressed sensing (PICCS). Methods: CBCT reconstruction method introduced in this study consisted of maximum a posteriori (MAP) iterative reconstruction combined with a regularization term derived from a concept of TCGM, which includes a constraint coming from the images of neighbouring time-phases. The time-ordered image series were concurrently reconstructed in the MAP iterative reconstruction framework. Angular range of projections for each time-phase was 90 degrees for TCGM and PICCS, and 200 degrees for TVCS. Two kinds of projection data, an elliptic-cylindrical digital phantom data and two clinical patients’ data, were used for reconstruction. The digital phantom contained an air sphere moving 3 cm along longitudinal axis, and temporal resolution of each method was evaluated by measuring the penumbral width of reconstructed moving air sphere. The clinical feasibility of non-periodic time-ordered 4D CBCT reconstruction was also examined using projection data of prostate cancer patients. Results: The results of reconstructed digital phantom shows that the penumbral widths of TCGM yielded the narrowest result; PICCS and TCGM were 10.6% and 17.4% narrower than that of TVCS, respectively. This suggests that the TCGM has the better temporal resolution than the others. Patients’ CBCT projection data were also reconstructed and all three reconstructed results showed motion of rectal gas and stool. The result of TCGM provided visually clearer and less blurring images. Conclusion: The present study demonstrates that the new concept for 4D CBCT reconstruction, TCGM, combined with MAP iterative reconstruction framework enables time-ordered image reconstruction with narrower time-window.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-05: Dosimetric and Radiobiological Validation of Respiratory Gating in Conventional and Hypofractionated Radiotherapy of the Lung: Effect of Dose, Dose Rate, Gating Window and Breathing Pattern

Purpose: to evaluate the dosimetric and radiobiological consequences from having different gating windows, dose rates, and breathing patterns in gated VMAT lung radiotherapy. Methods: A novel 3D-printed moving phantom with central high and peripheral low tracer uptake regions was 4D FDG-PET/CT-scanned using ideal, patient-specific regular, and irregular breathing patterns. A scan of the stationary phantom was obtained as a reference. Target volumes corresponding to different uptake regions were delineated. Simultaneous integrated boost (SIB) 6 MV VMAT plans were produced for conventional and hypofractionated radiotherapy, using 30–70 and 100% cycle gating scenarios. Prescribed doses were 200 cGy with SIB to 240 cGy to high uptake volume for conventional, and 800 with SIB to 900 cGy for hypofractionated plans. Dose rates of 600 MU/min (conventional and hypofractionated) and flattening filter free 1400 MU/min (hypofractionated) were used. Ion chamber measurements were performed to verify delivered doses. Vials with A549 cells placed in locations matching ion chamber measurements were irradiated using the same plans to measure clonogenic survival. Differences in survival for the different doses, dose rates, gating windows, and breathing patterns were analyzed. Results: Ion chamber measurements agreed within 3% of the planned dose, for all locations, breathing patterns and gating windows. Cell survival depended on dose alone, and not on gating window, breathing pattern, MU rate, or delivery time. The surviving fraction varied from approximately 40% at 2Gy to 1% for 9 Gy and was within statistical uncertainty relative to that observed for the stationary phantom. Conclusions: Use of gated VMAT in PET-driven SIB radiotherapy was validated using ion chamber measurements and cell survival assays for conventional and hypofractionated radiotherapy.

60 APPLIED LIFE SCIENCES↗