Search NASA⌕ Search

SEARCH · Search NASA

Results for “plane of array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Novel Deployment of Elpasolites as a Dual Neutron/Gamma-Ray Directional Detector

At a time when upholding national security has never been more important, there exists a need for the advancement of radiation detection technologies. Neutron and photon detectors are essential to fulfilling mission areas including detection and localization of missing, stolen or smuggled radiological or nuclear materials, quantification of the effects of a radiological or nuclear event, and supporting nonproliferation efforts. The aim of this study was to evaluate a new radiation detector based on the scintillation elpasolite compound Cs 2 LiYCl 6 :Ce (CLYC) for simultaneous measurements of neutron and photon flux and the localization of radiation sources. Previous studies performed on the CLYC scintillator indicate its potential for thermal neutron and gamma-ray measurements. This study is dedicated to the novel application of the CLYC as a dual neutron / photon detector and as part of a directional detection system. Both computational modeling and an experimental study were carried out within this research project. As part of the computational study, the response of a CLYC scintillator detector to gamma rays induced by thermal neutron interaction with Cl and 7 Li nuclei was investigated using the MCNP6 code. In addition, arrays of three and four CLYC detectors were modeled in order to evaluate the directional detection of both a thermal neutron source and a gamma-ray source. It was shown that little or no quality of source direction determination would be lost when three detectors were used in the array compared to four detectors. In the experimental study, the photon spectroscopy capabilities of the CLYC detectors were evaluated. A gamma-ray energy resolution of 4.9% was measured for the 662-keV peak of 137 Cs and 3.6% for the 1.33-MeV peak of 60 Co. Using a thermal neutron source, the pulse shape discrimination analysis was successfully performed for the CLYC detector signal waveforms. Thermal neutrons and gamma rays were separated with an exceptional figure of merit (FOM) of 2.3. An array of three CLYC detectors was assembled for the purpose of directional neutron / gamma-ray detection. The intrinsic peak efficiency of CLYC detectors was evaluated. The three-CLYC detector array was deployed for directional measurements with a single gamma-ray 137 Cs source, two gamma-ray sources of 137 Cs and 60 Co isotopes and a thermal neutron source designed using a 239PuBe neutron source supplied with a polyethylene moderator. Measurements were carried out using sources located in the longitude and latitude planes over the angles from 0° to 360°. The measured data were processed through a maximum likelihood estimation algorithm providing a possible direction for which the radioactive source in each case was positioned. The estimated directions were close if not exact matches for the actual directions to the radioactive source. The largest discrepancy in direction produced by the algorithm was approximately 11%. However, it was hypothesized that this percent error can be decreased by homogenizing the directional detection system to consist of scintillators of the same size and quality, identical photomultiplier tubes and identical aluminum housings. The feasibility of this hypothesis to decrease the percent error was confirmed by the zero percent error achieved in the directional measurements produced in the computational study utilizing a homogenous directional detection system. The results of computational and experimental studies completed within this research project provide means to propose the array of three CLYC scintillators as an efficient dual neutron / gamma-ray directional detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Isomeric states in neutron-deficient A{approx}80-90 nuclei populated in the fragmentation of {sup 107}Ag

The relativistic projectile fragmentation of a 750 MeV per nucleon beam of {sup 107}Ag was used to populate isomeric states in neutron-deficient nuclei around A=80-90. Reaction products were separated and unambiguously identified using the GSI FRagment Separator (FRS) and its ancillary detectors. At the final focal plane, the fragments were slowed from relativistic energies by means of an aluminium degrader and implanted in a passive stopper in the center of the high-efficiency, high-granularity Stopped Rare Isotope Spectroscopic INvestigation at GSI (RISING) germanium array. This allowed the identification of excited states in the N=Z nuclei {sub 43}{sup 86}Tc and, for the first time, {sub 41}{sup 82}Nb. Isomeric states have also been identified for the first time in {sup 87,88}Tc, and a previously unreported isomer was observed in {sup 84}Nb. Experimental results are presented along with a discussion on the structure of these nuclei based on interpretations provided by several theoretical models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EGS Collab Experiment 1: In-situ observation of pre-, co- and post-seismic shear slip preceding hydraulic fracturing

Understanding the initiation and arrest of earthquakes is one of the long-standing challenges of seismology. Here we report on direct observations of borehole displacement by a meter-sized shear rupture induced by pressurization of metamorphic rock at 1.5 km depth. We observed the acceleration of sliding, followed by fast co-seismic slip and a transient afterslip phase. Total displacements were about 7, 5.5 and 9.5 micrometers, respectively for the observed pre-slip, co-seismic slip and afterslip. The observed pre-slip lasted about 0.4 seconds. Co-seismic slip was recorded by the 1 kHz displacement recording and a 12-component array of 3-C accelerometers sampled at 100 kHz. The observed afterslip is consistent with analytical models of arrest in a velocity-strengthening region and subsequent stress relaxation. The observed slip vector agrees with the activation of a bedding plane within the phyllite, which is corroborated by relocated seismic events that were observed during the later stages of the injection experiment. This submission includes the pressure and deformation data recorded by the SIMFIP probe during the first injection at the 164 ft (50 m) notch of borehole E1-I. The injection was performed on on 05/22/2018 as part of Experiment 1 of the EGS Collab project. This data accompanies a manuscript submitted to GRL, linked in this submission.

15 GEOTHERMAL ENERGY↗

The EBEX Balloon-borne Experiment—Optics, Receiver, and Polarimetry

The E and B Experiment (EBEX) was a long-duration balloon-borne cosmic microwave background (CMB) polarimeter that flew over Antarctica in 2012. We describe the experiment's optical system, receiver, and polarimetric method and discuss their in-flight performance. EBEX had three frequency bands centered on 150, 250, and 410 GHz. To make effective use of limited mass and space, we created a 115 cm 2 sr high-throughput optical system that had two ambient temperature mirrors and four antireflection-coated polyethylene lenses per focal plane. All frequency bands shared the same optical train. Polarimetry was achieved with a continuously rotating achromatic half-wave plate (AHWP) that was levitated with a superconducting magnetic bearing (SMB). This is the first use of an SMB in astrophysics. Rotation stability was 0.45% over a period of 10 hr, and angular position accuracy was 0$^{°}_{.}$1. The measured modulation efficiency was above 90% for all bands. To our knowledge the 109% fractional bandwidth of the AHWP was the broadest implemented to date. The receiver, composed of one lens and the AHWP at a temperature of 4 K, the polarizing grid and other lenses at 1 K, and the two focal planes at 0.25 K, performed according to specifications, giving focal plane temperature stability with a fluctuation power spectrum that had a 1/f knee at 2 mHz. EBEX was the first balloon-borne instrument to implement technologies characteristic of modern CMB polarimeters, including high-throughput optical systems, and large arrays of transition edge sensor bolometric detectors with multiplexed readouts.

polarization↗

Acoustic Modifications of the Ames 40x80 Foot Wind Tunnel and Test Techniques for High-Speed Research Model Testing

The NFAC 40- by 80- Foot Wind Tunnel at Ames is being refurbished with a new, deep acoustic lining in the test section which will make the facility nearly anechoic over a large frequency range. The modification history, key elements, and schedule will be discussed. Design features and expected performance gains will be described. Background noise reductions will be summarized. Improvements in aeroacoustic research techniques have been developed and used recently at NFAC on several wind tunnel tests of High Speed Research models. Research on quiet inflow microphones and struts will be described. The Acoustic Survey Apparatus in the 40x80 will be illustrated. A special intensity probe was tested for source localization. Multi-channel, high speed digital data acquisition is now used for acoustics. And most important, phased microphone arrays have been developed and tested which have proven to be very powerful for source identification and increased signal-to-noise ratio. Use of these tools for the HEAT model will be illustrated. In addition, an acoustically absorbent symmetry plane was built to satisfy the HEAT semispan aerodynamic and acoustic requirements. Acoustic performance of that symmetry plane will be shown.

Soderman, Paul T.↗

Microstrip Yagi Antenna with Dual Aperture-Coupled Feed

A proposed microstrip Yagi antenna would operate at a frequency of 8.4 GHz (which is in the X band) and would feature a mechanically simpler, more elegant design, relative to a prior L-band microstrip Yagi antenna. In general, the purpose of designing a microstrip Yagi antenna is to combine features of a Yagi antenna with those of a microstrip patch to obtain an antenna that can be manufactured at low cost, has a low profile, and radiates a directive beam that, as plotted on an elevation plane perpendicular to the antenna plane, appears tilted away from the broadside. Such antennas are suitable for flush mounting on surfaces of diverse objects, including spacecraft, aircraft, land vehicles, and computers. Stated somewhat more precisely, what has been proposed is a microstrip antenna comprising an array of three Yagi elements. Each element would include four microstrip-patch Yagi subelements: one reflector patch, one driven patch, and two director patches. To obtain circular polarization, each driven patch would be fed by use of a dual offset aperture-coupled feed featuring bow-tie-shaped apertures. The selection of the dual offset bow-tie aperture geometry is supported by results found in published literature that show that this geometry would enable matching of the impedances of the driven patches to the 50-Omega impedance of the microstrip feedline while maintaining a desirably large front-to-back lobe ratio.

Pogorzelski, Ronald↗

Bioinspired Honeycomb Core Design: An Experimental Study of the Role of Corner Radius, Coping, and Interface

The honeybee’s nest has inspired the design of engineering honeycomb core that primarily abstract the hexagonal cell shape and exploit its mass minimizing properties to construct lightweight panels. This work explored three additional design features that are part of the natural honeybee comb but have not been traditionally considered as design features of interest in honeycomb design: the radius at the corner of each cell, the coping at the top of the cell walls, and the interface between cell arrays. These features were first characterized in natural honeycomb using optical and X-ray techniques, and then incorporated into honeycomb core design, and fabricated using an additive manufacturing process. The honeycomb cores were then tested in out-of-plane compression and bending, and since all three design features added mass to the overall structure, all metrics were examined per unit mass to assess performance gains. The study concluded that the addition of an interface increases specific flexural modulus but has little benefit in out-of-plane compression; coping radius positively impacts specific flexural strength; but that the corner radius has no significant effect in bending, and actually is slightly detrimental for out-of-plane compression testing.

honeycomb↗

Modeling dislocations in a polycrystal using the generalized finite element method.

Modeling the interaction of dislocations with internal boundaries and free surfaces is essential to understanding the effect of material microstructure on dislocation motion. However, discrete dislocation dynamics methods rely on infinite domain solutions of dislocation fields which makes modeling of heterogeneous materials difficult. A finite domain dislocation dynamics capability is under development that resolves both the dislocation array and polycrystalline structure in a compatible manner so that free surfaces and material interfaces are easily treated. In this approach the polycrystalline structure is accommodated using the GFEM, and the displacement due to the dislocation array is added to the displacement approximation. Shown in figure 1 are representative results from simulations of randomly placed and oriented dislocation sources in a cubic nickel polycrystal. Each grain has a randomly assigned (unique) material basis, and available glide planes are chosen accordingly. The change in basis between neighboring grains has an important effect on the motion of dislocations since the resolved shear on available glide planes can change dramatically. Dislocation transmission through high angle grain boundaries is assumed to occur by absorption into the boundary and subsequent nucleation in the neighboring grain. Such behavior is illustrated in figure 1d. Nucleation from the vertically oriented source in the bottom right grain is due to local stresses from dislocation pile-up in the neighboring grain. In this talk, the method and implementation is presented as well as some representative results from large scale (i.e., massively parallel) simulations of dislocation motion in cubic nano-domain nickel alloy. Particular attention will be paid to the effect of grain size on polycrystalline strength.

36 MATERIALS SCIENCE↗

In-situ observation of pre-, co- and post-seismic shear slip at 1.5 km depth

Understanding the initiation and arrest of earthquakes is one of the long-standing challenges of seismology. Here we report on direct observations of borehole displacement by a meter-sized shear rupture induced by pressurization of metamorphic rock at 1.5 km depth. We observed the acceleration of sliding, followed by fast co-seismic slip and transient afterslip. Total displacements were about 7, 5.5 and 9.5 micrometers, respectively for the observed pre-slip, co-seismic slip and afterslip. The observed pre-slip lasted about 0.4 seconds. Co-seismic slip was recorded by the 1 kHz displacement recording and a 12-component array of 3-C accelerometers sampled at 100 kHz. The observed afterslip is consistent with analytical models of arrest in a velocity-strengthening region and subsequent stress relaxation. < p >The observed slip vector agrees with the activation of a bedding plane within the phyllite, which is corroborated by relocated seismic events that were observed during the later stages of the injection experiment.

Schoenball, Martin↗

Machine learning control of an elliptically bent hard x-ray mirror

This article showcases the high-resolution control of an elliptically bent hard X-ray mirror optics at the Advanced Photon Source. The mirror uses a compact laminar flexure bending mechanism to achieve elliptical shapes covering a large range of focal distances. An array of capacitive sensors are used as a surface profiler for in-situ monitoring of the mirror shape. Machine learning and control techniques were used to change the mirror shape and focus the incident X-ray at predefined focal planes. The mirror surface shape error can be controlled to be within 40 nm rms with high repeatability. This technique gives the capability to focus incident X-ray beam within a range of focal distances corresponding to shape deformation range of a mirror optics. This work would be beneficial for controlling similar adaptive optics for multiple adaptive optics systems.

adaptive optics↗

Monolithic lead salt-silicon focal plane development

This paper is a summary of work done in the development of monolithic lead salt-silicon infrared focal plane technology. The photoconductive detector materials, PbS and PbSe are chemically deposited onto premetallized silicon MOSFET integrated circuit wafers. A variety of structures based on an implanted PMOS process were fabricated and evaluated. Operational results of an eight-element PbS array multiplexed on-chip are presented along with radiometric measurements on other integrated PbS-silicon MOSFET structures. PbS imagery is shown using one element of a 20-element array integrated on-chip.

Barrett, J. R.↗

The high-resolution structure of the Centaurus A nucleus at 2.3 and 8.4 GHz

VLBI observations of the nucleus of Centaurus A have been made at two frequencies with an array of five Australian radio telescopes as part of the Southern Hemisphere VLBI Experiment. Observations were made at 2.3 GHz with all five antennas, while only two were employed at 8.4 GHz. At 2.3 GHz seven tracks in the (u,v) plane with coverage of 6-8 hr each were obtained, yielding significant information on the structure of the nuclear jet. At 8.4 GHz a compact unresolved core was detected as well. It is found that the source consists of the compact self-absorbed core, a jet containing a set of three knots extending from 100 to 160 mas from the core, and a very long, narrow component elongated along the same position angle as the knots. The allowable range for the position angle of the jet is 51 + or - 3 deg, in agreement with that of the radio and X-ray structure on arcsecond and arcminute scales. The jet has brightened at 2.3 GHz by about 4 Jy, a factor of nearly 3, since the early 1970s, 1.8 Jy of which has occurred in the last 2 yr with no discernable changes in structure.

Meier, David L.↗

A chronology of the on-orbit pointing control system changes on the Hubble Space Telescope and associated pointing improvements

The pointing control system on the Hubble Space Telescope was designed to keep an image stable in the focal plane to 0.007 arc seconds (rms) for observations lasting from seconds to hours. Following the on-orbit deployment, this level of pointing performance was achieved only for short intervals during each orbit because of unexpected disturbances originating in the Solar Arrays. Since this problem was first recognized, several control system redesigns have been carried out and uplinked to the spacecraft with increasing degrees of success. This paper presents a chronology of those activities. In addition, sufficient background material is included regarding the pointing control system and the Solar Array disturbance so that the contents can be understood without reverting to the details in the reference material.

Sharkey, J. P.↗

Fundamental Limits on the Imaging and Polarisation Properties of Far-Infrared Detectors

Far-infrared bolometric detectors are used extensively in ground-based and space-borne astronomy, and thus it is important to understand their optical behaviour precisely. We have studied the intensity and polarisation response of free-space bolometers, and shown that when the size of the absorber is reduced below a wavelength, the response changes from being that of a classical optical detector to that of a few-mode antenna. We have calculated the modal content of the reception patterns, and found that for any volumetric detector having a side length of less than a wavelength, three magnetic and three electric dipoles characterize the behaviour. The size of the absorber merely determines the relative strengths of the contributions. The same formalism can be applied to thin-film absorbers, where the induced current is forced to flow in a plane. In this case, one magnetic and two electric dipoles characterize the behaviour. The ability to model easily the intensity, polarisation, and straylight characteristics of electrically-small detectors will be of great value when designing high-performance polarimetric imaging arrays.

Thomas, Christopher N.↗

Multi-Point Line Focused Laser Differential Interferometer for High-Speed Flow Fluctuation Measurements

A multi-point focused laser differential interferometer (FLDI) has been developed to measure density fluctuations at 16 points along a line. A pair of cylindrical lenses on the transmitter side of a conventional single-point FLDI instrument form two closely spaced (≤200 μm), orthogonally polarized, parallel laser lines at the instrument’s focus. On the receiver side of the instrument, the interference of the beams on a 16-element photodiode array results in a single line of measurements. The further addition of a Nomarski prism creates two separate measurement lines, and the addition of a second photodiode array to the instrument enables simultaneous measurements of density fluctuations along the two lines separated by several millimeters. These two lines of measurement can be conveniently oriented at any azimuthal angle relative to the instrument’s optical axis on the measurement plane, coinciding with the instrument’s focus. Two experiments were performed to demonstrate the capabilities of the instrument. In the first experiment, a laser-induced breakdown spark generated a traveling spherical shock wave, and measurements of the resulting density disturbance and wave velocity were obtained. These results were compared to high-speed schlieren images of the shock wave acquired at 400 kHz. In the second experiment, the multi-point FLDI instrument was used to measure density disturbances in the boundary layer of a flat plate in a Mach 6 freestream flow. The measurements were made along two lines, both approximately 6 mm in length, extending from the surface of the plate through the boundary layer. High-speed schlieren images were acquired at 100 kHz during separate wind tunnel runs at matching unit Reynolds numbers to visualize the unsteady boundary layer flow and compare to the FLDI measurements.

Laser beam shaping↗

The Barrel Calorimeter for the GlueX Experiment at Jefferson Lab

The GlueX experiment at Jefferson Lab will search for exotic hybrid mesons as evidence of gluonic excitations, in an effort to understand confinement in QCD. The key features of this compelling physics program will be presented together with an overview of the detector, focusing on the electromagnetic barrel calorimeter (BCAL). The BCAL is a 'spaghetti calorimeter,' consisting of layers of corrugated lead sheets, interleaved with planes of 1-mm-diameter, double-clad, scintillating fibres, bonded in the lead grooves using optical epoxy. This detector will consist of 48 modules and will be readout using 3,840 large-area Multi-Photon Pixel counter arrays. The experiment is now in the installation phase with data taking expected in 2015.

Papandreou, Zisis↗

A Diamond Micro-strip Electron Detector for Compton Polarimetry

The Qweak experiment in Hall C at Jefferson Lab aims to measure the weak charge of the proton with a precision of 4.1{\%} by measuring the parity violating asymmetry in polarized electron-proton elastic scattering. Beam polarimetry is the largest experimental contribution to the error budget. A new Compton polarimeter was installed for a non-invasive and continuous monitoring of the electron beam polarization with a goal of 1{\%} systematic and 1{\%} per hour statistical precision. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. These detectors are read out using custom built electronic modules that include a pre-amplifier, a pulse shaping amplifier and a discriminator for each detector micro-strip. We use Field Programmable Gate Array based general purpose logic modules for event selection and histogramming. The polarimeter was commissioned during the first run period of the Qweak experiment. We will show the preliminary results from the electron detector obtained during the first run period of Qweak experiment.

Narayan, Amrendra↗

Hard x-ray response of pixellated CdZnTe detectors

In recent years, the development of cadmium zinc telluride (CdZnTe) detectors for x-ray and gamma ray spectrometry has grown rapidly. The good room temperature performance and the high spatial resolution of pixellated CdZnTe detectors make them very attractive in space-borne x-ray astronomy, mainly as focal plane detectors for the new generation of hard x-ray focusing telescopes. In this work, we investigated on the spectroscopic performance of two pixellated CdZnTe detectors coupled with a custom low noise and low power readout application specific integrated circuit (ASIC). The detectors (10x10x1 and 10x10x2 mm{sup 3} single crystals) have an anode layout based on an array of 256 pixels with a geometric pitch of 0.5 mm. The ASIC, fabricated in 0.8 mum BiCMOS technology, is equipped with eight independent channels (preamplifier and shaper) and characterized by low power consumption (0.5 mW/channel) and low noise (150-500 electrons rms). The spectroscopic results point out the good energy resolution of both detectors at room temperature [5.8% full width at half maximum (FWHM) at 59.5 keV for the 1 mm thick detector; 5.5% FWHM at 59.5 keV for the 2 mm thick detector) and low tailing in the measured spectra, confirming the single charge carrier sensing properties of the CdZnTe detectors equipped with a pixellated anode layout. Temperature measurements show optimum performance of the system (detector and electronics) at T=10 deg.C and performance degradation at lower temperatures. The detectors and the ASIC were developed by our collaboration as two small focal plane detector prototypes for hard x-ray multilayer telescopes operating in the 20-70 keV energy range.

36 MATERIALS SCIENCE↗