Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Simulation Study of High-Precision Characterization of MeV Electron Interactions for Advanced Nano-Imaging of Thick Biological Samples and Microchips

The resolution of a mega-electron-volt scanning transmission electron microscope (MeV-STEM) is primarily governed by the properties of the incident electron beam and angular broadening effects that occur within thick biological samples and microchips. A precise understanding and mitigation of these constraints require detailed knowledge of beam emittance, aberrations in the STEM column optics, and energy-dependent elastic and inelastic critical angles of the materials being examined. This simulation study proposes a standardized experimental framework for comprehensively assessing beam intensity, divergence, and size at the sample exit. This framework aims to characterize electron-sample interactions, reconcile discrepancies among analytical models, and validate Monte Carlo (MC) simulations for enhanced predictive accuracy. Our numerical findings demonstrate that precise measurements of these parameters, especially angular broadening, are not only feasible but also essential for optimizing imaging resolution in thick biological samples and microchips. By utilizing an electron source with minimal emittance and tailored beam characteristics, along with amorphous ice and silicon samples as biological proxies and microchip materials, this research seeks to optimize electron beam energy by focusing on parameters to improve the resolution in MeV-STEM/TEM. This optimization is particularly crucial for in situ imaging of thick biological samples and for examining microchip defects with nanometer resolutions. Our ultimate goal is to develop a comprehensive mapping of the minimum electron energy required to achieve a nanoscale resolution, taking into account variations in sample thickness, composition, and imaging mode.

36 MATERIALS SCIENCE↗

Laser extensometer

A drift compensated and intensity averaged extensometer for measuring the diameter or other properties of a substantially cylindrical sample based upon the shadow of the sample is described. A beam of laser light is shaped to provide a beam with a uniform intensity along an axis normal to the sample. After passing the sample, the portion of the beam not striking said sample is divided by a beam splitter into a reference signal and a measurement signal. Both of these beams are then chopped by a light chopper to fall upon two photodiode detectors. The resulting ac currents are rectified and then divided into one another, with the final output being proportional to the size of the sample shadow.

Stocker, P. J.↗

A universal and constant rate of gene content change traces pangenome flux to LUCA

Abstract Prokaryotic genomes constantly undergo gene flux via lateral gene transfer, generating a pangenome structure consisting of a conserved core genome surrounded by a more variable accessory genome shell. Over time, flux generates change in genome content. Here, we measure and compare the rate of genome flux for 5655 prokaryotic genomes as a function of amino acid sequence divergence in 36 universally distributed proteins of the informational core (IC). We find a clock of gene content change. The long-term average rate of gene content flux is remarkably constant across all higher prokaryotic taxa sampled, whereby the size of the accessory genome—the proportion of the genome harboring gene content difference for genome pairs—varies across taxa. The proportion of species-level accessory genes per genome, varies from 0% (Chlamydia) to 30%–33% (Alphaproteobacteria, Gammaproteobacteria, and Clostridia). A clock-like rate of gene content change across all prokaryotic taxa sampled suggest that pangenome structure is a general feature of prokaryotic genomes and that it has been in existence since the divergence of bacteria and archaea.

Microbiology↗

Effects of Ti doping on the dielectric properties of HfO{sub 2} nanoparticles

We report the effects of Ti doping on the dielectric properties of HfO{sub 2} [Hf{sub 1-x}Ti{sub x}O{sub 2} (x = 0.2-0.8)] nanoparticles at room temperature. The Hf{sub 1-x}Ti{sub x}O{sub 2} nanoparticles were synthesized by a wet chemical process. The structural and morphological properties of the derived samples were analyzed with X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR) and high resolution transmission electron microscopy (HRTEM). Impedance analysis was performed in pelletized samples in the frequency range of 1 MHz to 1 GHz. The obtained results were analyzed in correlation with microstructure and doping concentration in the derived samples. The average size of the Hf{sub 1-x}Ti{sub x}O{sub 2} nanoparticles is typically in the range of 4-8 nm depending on the processing temperature. The Hf{sub 1−x}Ti{sub x}O{sub 2} nanoparticles show reduction in crystallinity with the increase in Ti doping. The dielectric constants of the derived samples decrease with the increase in frequency. The ac-conductivity in the samples increases with the increase in frequency irrespective of Ti concentration and shows significant drop with the increase in Ti concentration at all frequencies.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Spin Glass Behavior in La{sub 0.7}Ca{sub 0.23}Sr{sub 0.07}MnO{sub 3} Nanofibers Obtained by Electrospinning

This work contributes to the development of new nanostructured mixed valence manganites and to explore and optimize their magnetic properties at 1-D level. Nanofibers of La{sub 0.7}Ca{sub 0.23}Sr{sub 0.07}MnO{sub 3} manganite were fabricated using the electrospinning method and three different heat treatments to determine how the nanostructure affects its thermomagnetic behavior. From scanning electron microscopy, nanofibers morphology was observed and average diameters of 75, 94, and 97 nm were identified after heat treatments of 973, 1073, and 1173 K, respectively. According to X-ray diffraction technique, a single-phase orthorhombic structure was defined for each sample. Average crystallite sizes were determined as 47, 49, and 58 nm. A ferromagnetic to paramagnetic transition with Curie temperatures of 297, 305, and 314 K were identified, respectively. Furthermore, a glassy state was induced by nanofibers agglomeration. The spin glass and irreversible temperatures diminished as the magnetic field was increased and a highly anisotropic state was evidenced for all samples. Thermomagnetic behavior in manganites showed to be significantly influenced by the one-dimensional structure and exposed how the dimensionality proportionated by the fabrication method can be used to adjust magnetic properties.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A COMPREHENSIVE STATISTICAL DESCRIPTION OF RADIO-THROUGH- γ -RAY SPECTRAL ENERGY DISTRIBUTIONS OF ALL KNOWN BLAZARS

We combined multi-wavelength data for blazars from the Roma-BZCAT catalog and analyzed hundreds of X-ray spectra. We present the fluxes and spectral energy distributions (SEDs), in 12 frequency bands from radio to γ -rays, for a final sample of 2214 blazars. Using a model-independent statistical approach, we looked for systematic trends in the SEDs; the most significant trends involved the radio luminosities and X-ray spectral indices of the blazars. We used a principal component analysis (PCA) to determine the basis vectors of the blazar SEDs and, in order to maximize the size of the sample, imputed missing fluxes using the K -nearest neighbors method. Using more than an order of magnitude more data than was available when Fossati et al. first reported trends of SED shape with blazar luminosity, we confirmed the anti-correlation between radio luminosity and synchrotron peak frequency, although with greater scatter than was seen in the smaller sample. The same trend can be seen between bolometric luminosity and synchrotron peak frequency. Finally, we used all of the available blazar data to determine an empirical SED description that depends only on the radio luminosity at 1.4 GHz and the redshift. We verified that this statistically significant relation was not a result of the luminosity–luminosity correlations that are natural in flux-limited samples (i.e., where the correlation is actually caused by the redshift rather than the luminosity).

79 ASTRONOMY AND ASTROPHYSICS↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

Method of assessing a lipid-related health risk based on ion mobility analysis of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

Benner, W Henry↗

Aerosol preparation of intact lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

60 APPLIED LIFE SCIENCES↗

Determining the risk of cardiovascular disease using ion mobility of lipoproteins

A medical diagnostic method and instrumentation system for analyzing noncovalently bonded agglomerated biological particles is described. The method and system comprises: a method of preparation for the biological particles; an electrospray generator; an alpha particle radiation source; a differential mobility analyzer; a particle counter; and data acquisition and analysis means. The medical device is useful for the assessment of human diseases, such as cardiac disease risk and hyperlipidemia, by rapid quantitative analysis of lipoprotein fraction densities. Initially, purification procedures are described to reduce an initial blood sample to an analytical input to the instrument. The measured sizes from the analytical sample are correlated with densities, resulting in a spectrum of lipoprotein densities. The lipoprotein density distribution can then be used to characterize cardiac and other lipid-related health risks.

59 BASIC BIOLOGICAL SCIENCES↗

Mapping wall-to-wall fractional cover of Arctic tundra plant functional types in Alaska using 20-m spatial resolution satellite imagery and harmonized plot observations

Estimates of fractional cover (fCover) across given land surfaces are used to assess, and often model, vegetation composition and diversity, which are crucial for understanding the health and functioning of terrestrial ecosystems. Remote sensing provides a useful means for scaling local, plot-measured fCover estimates to regional scales. Leveraging a recently synthesized and harmonized plot database, this study generated wall-to-wall maps of fCover for six Alaskan-Arctic plant functional types (PFT), including non-vascular plants, forbs, graminoids, and deciduous and evergreen shrubs, using 20-m satellite data (Sentinel-1, Sentinel-2, ArcticDEM) using a machine learning regression approach, specifically the random forest (RF) algorithm, which is well-suited for handling nonlinear relationships and high-dimensional satellite datasets. This study additionally addressed the spatio-temporal inconsistencies e.g., sampling scale, plot size, and collection year in plot measured fCover by adopting a multivariate outlier detection approach—Cook’s distance—to identify high-quality plots for model training and validation. Our approach achieves high accuracy (R 2 = 0.59–0.93, root mean squared errors = 0.02–0.10 for all PFTs) between plot-observed and satellite-derived fCover when using high-quality plot samples. The mapped fCover characterizes the spatial patterns of different PFTs across the tundra biome at a 20-m resolution, providing key information needed for improved representation of Arctic tundra vegetation in terrestrial biosphere models to better understand climate-vegetation feedback across the Arctic tundra.

Arctic tundra↗

Size dependent compressibility of nano-ceria: Minimum near 33 nm

We report the crystallite-size-dependency of the compressibility of nanoceria under hydrostatic pressure for a wide variety of crystallite diameters and comment on the size-based trends indicating an extremum near 33 nm. Uniform nano-crystals of ceria were synthesized by basic precipitation from cerium (III) nitrate. Size-control was achieved by adjusting mixing time and, for larger particles, a subsequent annealing temperature. The nano-crystals were characterized by transmission electron microscopy and standard ambient x-ray diffraction (XRD). Compressibility, or its reciprocal, bulk modulus, was measured with high-pressure XRD at LBL-ALS, using helium, neon, or argon as the pressure-transmitting medium for all samples. As crystallite size decreased below 100 nm, the bulk modulus first increased, and then decreased, achieving a maximum near a crystallite diameter of 33 nm. We review earlier work and examine several possible explanations for the peaking of bulk modulus at an intermediate crystallite size.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

On evaluating compliance with air pollution levels not to be exceeded more than once per year

The adequacy is considered of currently practiced monitoring and data reduction techniques for assessing compliance with 24-hour Air Quality Standards (AQS) not to be exceeded more than once per year. The present situation for suspended particulates is discussed. The following conclusions are reached: (1) For typical less than daily sampling (i.e., 60 to 120 24-hour samples per year) the deviation from independence of the data set should not be substantial. (2) The interchange of exponentiation and expectation operations in the EPA data reduction model, underestimates the second highest level by about 4 to 8 percent for typical sigma values. (3) Estimates of the second highest pollution level have associated with them a large statistical variability arising from the finite size of the sample. The 0.95 confidence interval ranges from + or - 40 percent for 120 samples per year to + or - 84 percent for 30 samples per year. (4) The design value suggested by EPA for abatement and/or control planning purposes typically gives a margin of safety of 60 to 120 percent.

Neustadter, H. E.↗

Petrologic profile of Apollo 16 regolith at Station 4

The Apollo 16 double drive tube core 64001/2 (total depth about 60 cm) consists of four petrologic units based on the modal abundance of lithic, monomineralic, and other particles in the 20-500 micron size range of samples from 12 levels. Variation in the abundance of particles derived directly from bedrocks is low and the core soils probably represent only one set of source rocks. The chemical signature of an excessively high mare basalt component at about 42 cm correlates with an excess of regolith breccias, which may then be the physical carrier. The core soils as a whole show a systematic size-composition relationship that may be attributed to a large-scale macroscopic reworking and the consequent masking of any or all previous surface process related mixing event. However, on a much smaller scale (about 0.5 cm), individual soil layers seem to have evolved more via mixing than via in situ reworking.

Basu, A.↗

A coronagraphic search for brown dwarfs around nearby stars

Brown dwarf companions have been searched for around stars within 10 pc of the Sun using the Johns-Hopkins University Adaptive Optics Coronagraph (AOC), a stellar coronagraph with an image stabilizer. The AOC covers the field around the target star with a minimum search radius of 1 sec .5 and a field of view of 1 arcmin sq. We have reached an unprecedented dynamic range of Delta m = 13 in our search for faint companions at I band. Comparison of our survey with other brown dwarf searches shows that the AOC technique is unique in its dynamic range while at the same time just as sensitive to brown dwarfs as the recent brown dwarf surveys. The present survey covered 24 target stars selected from the Gliese catalog. A total of 94 stars were detected in 16 fields. The low-latitude fields are completely dominated by background star contamination. Kolmogorov-Smirnov tests were carried out for a sample restricted to high latitudes and a sample with small angular separations. The high-latitude sample (b greater than or equal to 44 deg) appears to show spatial concentration toward target stars. The small separation sample (Delta Theta less than 20 sec) shows weaker dependence on Galactic coordinates than field stars. These statistical tests suggest that both the high-latitude sample and the small separation sample can include a substantial fraction of true companions. However, the nature of these putative companions is mysterious. They are too faint to be white dwarfs and too blue for brown dwarfs. Ignoring the signif icance of the statistical tests, we can reconcile most of the detections with distant main-sequence stars or white dwarfs except for a candidate next to GL 475. Given the small size of our sample, we conclude that considerably more targets need to be surveyed before a firm conclusion on the possibility of a new class of companions can be made.

Nakajima, T.↗

Examination of Multiple Lithologies Within the Primitive Ordinary Chondrite NWA 5717

Northwest Africa 5717 is a primitive (subtype 3.05) ungrouped ordinary chondrite which contains two apparently distinct lithologies. In large cut meteorite slabs, the darker of these, lithology A, looks to host the second, much lighter in color, lithology B (upper left, Fig. 1). The nature of the boundary between the two is uncertain, ranging from abrupt to gradational and not always following particle boundaries. The distinction between the lithologies, beyond the obvious color differences, has been supported by a discrepancy in oxygen isotopes and an incongruity in the magnesium contents of chondrule olivine. Here, quantitative textural analysis and mineralogical methods have been used to investigate the two apparent lithologies within NWA 5717. Olivine grains contained in a thin section from NWA 7402, thought to be paired to 5717, were also measured to re-examine the distinct compositional range among the light and dark areas. Procedure: Particles from a high-resolution mosaic image of a roughly 13x15cm slice of NWA 5717 were traced in Adobe Photoshop. Due to the large size of the sample, visually representative regions of each lithology were chosen to be analyzed. The resulting layers of digitized particles were imported into ImageJ, which was used to measure their area, along with the axes, the angle from horizontal, and the centroid coordinates of ellipses fitted to each particle following the approach. Resulting 2D pixel areas were converted to spherical diameters employing the unfolding algorithm, which outputs a 3D particle size distribution based on digitized 2D size frequency data. Spatstat was used to create kernel density plots of the centroid coordinates for each region. X-ray compositional maps, microprobe analyses, and Mossbauer spectroscopy was conducted on a thin section of NWA 7402, tentatively paired to NWA 5717.

Cato, M. J.↗

Improved Scanning Geometry to Collect 3D-Geometry Data in Flat Samples

3D integration through silicon technology of integrated circuits challenges non-destructive testing methods. 3D x-ray methods are the techniques of choice to localize defects in interconnects. The development of high-power x-ray sources enabled the use of x-ray microscopy in laboratory tools. Those devices are able to resolve features down to 40 nm in an acceptable measurement time. However, the field of view is very limited to 16 {mu}m in high-resolution mode and to 65 {mu}m in large-field-of-view mode. To record tomography data, the size of the samples must not exceed the field of view to circumvent specific artifacts. Semiconductor samples usually do not fulfill the condition mentioned above since they have the shape of flat sheets. Therefore limited-angle tomography is typically used. The missing angles cause typical capping artifacts and poor signal-to-noise ratio. We present a modified scanning geometry that overcomes some of the artifacts and yields a better image quality. The geometry and potential applications are presented in comparison to the traditional limited-angle tomography.

07 ISOTOPE AND RADIATION SOURCES↗