Search NASA⌕ Search

SEARCH · Search NASA

Results for “self”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,711 records · Page 95

Self-duality under gauging a non-invertible symmetry

Abstract We discuss two-dimensional conformal field theories (CFTs) which are invariant under gauging a non-invertible global symmetry. At every point on the orbifold branch ofc= 1 CFTs, it is known that the theory is self-dual under gauging a ℤ 2 × ℤ 2 symmetry, and has Rep(H 8 ) and Rep(D 8 ) fusion category symmetries as a result. We find that gauging the entire Rep(H 8 ) fusion category symmetry maps the orbifold theory at radiusRto that at radius 2/R. AtR=$$ \sqrt{2} $$ 2 , which corresponds to two decoupled Ising CFTs (Ising 2 in short), the theory is self-dual under gauging the Rep(H 8 ) symmetry. This implies the existence of a topological defect line in the Ising 2 CFT obtained from half-space gauging of the Rep(H 8 ) symmetry, which commutes with thec= 1 Virasoro algebra but does not preserve the fully extended chiral algebra. We bootstrap its action on thec= 1 Virasoro primary operators, and find that there are no relevant or marginal operators preserving it. Mathematically, the new topological line combines with the Rep(H 8 ) symmetry to form a bigger fusion category which is a ℤ 2 -extension of Rep(H 8 ). We solve the pentagon equations including the additional topological line and find 8 solutions, where two of them are realized in the Ising 2 CFT. Finally, we show that the torus partition functions of the Monster 2 CFT and Ising×Monster CFT are also invariant under gauging the Rep(H 8 ) symmetry.

Physics↗

Higgs self-coupling measurements at a 100 TeV hadron collider

An important physics goal of a possible next-generation high-energy hadron collider will be precision characterisation of the Higgs sector and electroweak symmetry breaking. A crucial part of understanding the nature of electroweak symmetry breaking is measuring the Higgs self-interactions. We study dihiggs production in proton-proton collisions at 100 TeV centre of mass energy in order to estimate the sensitivity such a machine would have to variations in the trilinear Higgs coupling around the Standard Model expectation. We focus on the bb¯γγ final state, including possible enhancements in sensitivity by exploiting dihiggs recoils against a hard jet. In conclusion, we find that it should be possible to measure the trilinear self-coupling with 40% accuracy given 3/ab and 12% with 30/ab of data.

43 PARTICLE ACCELERATORS↗

A global view on the Higgs self-coupling at lepton colliders

We perform a global effective-field-theory analysis to assess the precision on the determination of the Higgs trilinear self-coupling at future lepton colliders. Two main scenarios are considered, depending on whether the center-of-mass energy of the colliders is sufficient or not to access Higgs pair production processes. Low-energy machines allow for ~40% precision on the extraction of the Higgs trilinear coupling through the exploitation of next-to-leading-order effects in single Higgs measurements, provided that runs at both 240/250 GeV and 350 GeV are available with luminosities in the few attobarns range. A global fit, including possible deviations in other SM couplings, is essential in this case to obtain a robust determination of the Higgs self-coupling. High-energy machines can easily achieve a ~20% precision through Higgs pair production processes. In this case, the impact of additional coupling modifications is milder, although not completely negligible.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gravitational self force from scattering amplitudes in curved space

Abstract We employ scattering amplitudes in curved space to model the dynamics of a light probe particle with massmorbiting in the background spacetime induced by a heavy gravitational source with massM. Observables are organized as an expansion inm/Mto all orders inG— the gravitational self-force expansion. An essential component of our analysis is the backreaction of the heavy source which we capture by including the associated light degrees of freedom. As illustration we consider a Schwarzschild background and verify geodesic motion as well as the first-order self-force correction to two-body scattering through$$\mathcal{O}$$(G 3 ). Amplitudes in curved space offer several advantages, and further developments along these lines may advance the computation of gravitational-wave signals for extreme-mass-ratio inspirals.

Physics↗

Gravitational causality and the self-stress of photons

We study causality in gravitational systems beyond the classical limit. Using on-shell methods, we consider the 1-loop corrections from charged particles to the photon energy-momentum tensor — the self-stress — that controls the quantum interaction between two on-shell photons and one off-shell graviton. The self-stress determines in turn the phase shift and time delay in the scattering of photons against a spectator particle of any spin in the eikonal regime. We show that the sign of the β-function associated to the running gauge coupling is related to the sign of time delay at small impact parameter. Our results show that, at first post-Minkowskian order, asymptotic causality, where the time delay experienced by any particle must be positive, is respected quantum mechanically. Contrasted with asymptotic causality, we explore a local notion of causality, where the time delay is longer than the one of gravitons, which is seemingly violated by quantum effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-interacting dark matter and muon (g - 2) in a gauged U ( 1 ) L &#x03BC;<!-- μ --> &#x2212;<!-- - --> L &#x03C4;<!-- τ --> model

We construct a self-interacting dark matter model that could simultaneously explain the observed muon anomalous magnetic moment. It is based on a gauged U ( 1 ) L &#x03BC;<!-- μ --> &#x2212;<!-- - --> L &#x03C4;<!-- τ --> extension of the standard model, where we introduce a vector-like pair of fermions as the dark matter candidate and a new Higgs boson to break the symmetry. The new gauge boson has a sizable contribution to muon (g - 2), while being consistent with other experimental constraints. The U ( 1 ) L &#x03BC;<!-- μ --> &#x2212;<!-- - --> L &#x03C4;<!-- τ --> Higgs boson acts as a light force carrier, mediating dark matter self-interactions with a velocity-dependent cross section. It is large enough in galaxies to thermalize the inner halo and explain the diverse rotation curves and diminishes towards galaxy clusters. Since the light mediator dominantly decays to the U ( 1 ) L &#x03BC;<!-- μ --> &#x2212;<!-- - --> L &#x03C4;<!-- τ --> gauge boson and neutrinos, the astrophysical and cosmological constraints are weak. We study the thermal evolution of the model in the early Universe and derive a lower bound on the gauge boson mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Self-dual 6d 2-form fields coupled to non-abelian gauge field: quantum corrections

We study a 6d model of a set of self-dual 2-form B -fields interacting with a non-abelian vector A -field which is restricted to a 5d subspace. One motivation is that if the gauge vector could be expressed in terms of the B -field or integrated out, this model could lead to an interacting theory of B -fields only. Treating the 5d gauge vector as a background field, we compute the divergent part of the corresponding one-loop effective action which has the ( DF ) 2 + F 3 structure and compare it with similar contributions from other 6d fields. We also discuss a 4d analog of the non-abelian self-dual model, which turns out to be UV finite.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

All orders results for self-crossing Wilson loops mimicking double parton scattering

Loop-level scattering amplitudes for massless particles have singularities in regions where tree amplitudes are perfectly smooth. For example, a 2 → 4 gluon scattering process has a singularity in which each incoming gluon splits into a pair of gluons, followed by a pair of 2 → 2 collisions between the gluon pairs. This singularity mimics double parton scattering because it occurs when the transverse momentum of a pair of outgoing gluons vanishes. The singularity is logarithmic at fixed order in perturbation theory. We exploit the duality between scattering amplitudes and polygonal Wilson loops to study six-point amplitudes in this limit to high loop order in planar N = 4 super-Yang-Mills theory. The singular configuration corresponds to the limit in which a hexagonal Wilson loop develops a self-crossing. The singular terms are governed by an evolution equation, in which the hexagon mixes into a pair of boxes; the mixing back is suppressed in the planar (large N c) limit. Because the kinematic dependence of the box Wilson loops is dictated by (dual) conformal invariance, the complete kinematic dependence of the singular terms for the self-crossing hexagon on the one nonsingular variable is determined to all loop orders. The complete logarithmic dependence on the singular variable can be obtained through nine loops, up to a couple of constants, using a correspondence with the multi-Regge limit. As a byproduct, we obtain a simple formula for the leading logs to all loop orders. Furthermore, we also show that, although the MHV six-gluon amplitude is singular, remarkably, the transcendental functions entering the non-MHV amplitude are finite in the same limit, at least through four loops.

1/N expansion scattering amplitudes↗

Self-Destructing Dark Matter

We present Self-Destructing Dark Matter (SDDM), a new class of dark matter models which are detectable in large neutrino detectors. In this class of models, a component of dark matter can transition from a long-lived state to a short-lived one by scattering off of a nucleus or an electron in the Earth. The short-lived state then decays to Standard Model particles, generating a dark matter signal with a visible energy of order the dark matter mass rather than just its recoil. This leads to striking signals in large detectors with high energy thresholds. We present a few examples of models which exhibit self destruction, all inspired by bound state dynamics in the Standard Model. The models under consideration exhibit a rich phenomenology, possibly featuring events with one, two, or even three lepton pairs, each with a fixed invariant mass and a fixed energy, as well as non-trivial directional distributions. This motivates dedicated searches for dark matter in large underground detectors such as Super-K, Borexino, SNO+, and DUNE.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effective theories for a nonrelativistic field in an expanding universe: Induced self-interaction, pressure, sound speed, and viscosity

A massive, nonrelativistic scalar field in an expanding spacetime is usually approximated by a pressureless perfect fluid, which leads to the standard conclusion that such a field can play the role of cold dark matter. In this paper, we systematically study these approximations, incorporating subleading corrections. We provide two equivalent effective descriptions of the system, each of which offers its own advantages and insights: (i) A nonrelativistic effective field theory (EFT) with which we show that the relativistic corrections induce an effective self-interaction for the nonrelativistic field. As a byproduct, our EFT also allows one to construct the exact solution, including oscillatory behavior, which is often difficult to achieve from the exact equations. (ii) An effective (imperfect) fluid description, with which we demonstrate that, for a perturbed Friedmann-Lemaître- Robertson-Walker (FLRW) universe: (a) The pressure is small but nonzero (and positive), even for a free theory with no tree-level self-interactions. (b) The sound speed of small fluctuations is also nonzero (and positive), reproducing already known leading-order results, correcting a subdominant term, and identifying a new contribution that had been omitted in previous analyses. (c) The fluctuations experience a negative effective bulk viscosity. The positive sound speed and the negative bulk viscosity act in favor of and against the growth of overdensities, respectively. The net effect may be considered a smoking gun for ultra-light dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Systematizing the effective theory of self-interacting dark matter

If dark matter has strong self-interactions, future astrophysical and cosmological observations, together with a clearer understanding of baryonic feedback effects, might be used to extract the velocity dependence of the dark matter scattering rate. To interpret such data, we should understand what predictions for this quantity are made by various models of the underlying particle nature of dark matter. In this paper, we systematically compute this function for fermionic dark matter with light bosonic mediators of vector, scalar, axial vector, and pseudoscalar type. We do this by matching to the nonrelativistic effective theory of self-interacting dark matter and then computing the spin-averaged viscosity cross section nonperturbatively by solving the Schrödinger equation, thus accounting for any possible Sommerfeld enhancement of the low-velocity cross section. In the pseudoscalar case, this requires a coupled-channel analysis of different angular momentum modes. We find, contrary to some earlier analyses, that nonrelativistic effects only provide a significant enhancement for the cases of light scalar and vector mediators. Scattering from light pseudoscalar and axial vector mediators is well described by tree-level quantum field theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the Higgs self coupling via single Higgs production at the LHC

Here, we propose a method to determine the trilinear Higgs self coupling that is alternative to the direct measurement of Higgs pair production total cross sections and differential distributions. Furthermore, the method relies on the effects that electroweak loops featuring an anomalous trilinear coupling would imprint on single Higgs production at the LHC. We first calculate these contributions to all the phenomenologically relevant Higgs production (ggF, VBF, WH, ZH, t$\bar{t}$ ) and decay (γγ,WW*/ZZ*→ 4f, b$\bar{b}$,ττ) modes at the LHC and then estimate the sensitivity to the trilinear coupling via a one-parameter fit to the single Higgs measurements at the LHC 8 TeV. We also found that the bounds on the self coupling are already competitive with those from Higgs pair production and will be further improved in the current and next LHC runs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral Solutions of Self-adjoint Elliptic Problems with Immersed Interfaces

This paper describes a spectral representation of solutions of self-adjoint elliptic problems with immersed interfaces. The interface is assumed to be a simple non-self-intersecting closed curve that obeys some weak regularity conditions. The problem is decomposed into two problems, one with zero interface data and the other with zero exterior boundary data. The problem with zero interface data is solved by standard spectral methods. The problem with non-zero interface data is solved by introducing an interface space H{sub {Gamma}}({Omega}) and constructing an orthonormal basis of this space. This basis is constructed using a special class of orthogonal eigenfunctions analogously to the methods used for standard trace spaces by Auchmuty (SIAM J. Math. Anal. 38, 894-915, 2006). Analytical and numerical approximations of these eigenfunctions are described and some simulations are presented.

97 MATHEMATICS AND COMPUTING↗

Malignant Gastroduodenal Obstruction: Treatment with Self-Expanding Uncovered Wallstent

Purpose: To retrospectively evaluate the clinical effectiveness of a self-expanding uncovered Wallstent in patients with malignant gastroduodenal obstruction. Materials and Methods: Under combined endoscopic and fluoroscopic guidance, 29 patients with a malignant gastroduodenal stenosis were treated with a self-expanding uncovered metallic Wallstent. A dysphagia score was assessed before and after the intervention to measure the success of this palliative therapy. The dysphagia score ranged between grade 0 to grade 4: grade 0 = able to tolerate solid food, grade 1 = able to tolerate soft food, grade 2 = able to tolerate thick liquids, grade 3 = able to tolerate water or clear fluids, and grade 4 = unable to tolerate anything perorally. Stent patency and patients survival rates were calculated. Results: The insertion of the gastroduodenal stent was technically successful in 28 patients (96.5%). After stenting, 25 patients (86.2%) showed clinical improvement by at least one score point. During follow-up, 22 (78.5%) of 28 patients showed no stent occlusion until death and did not have to undergo any further intervention. In six patients (20.6%), all of whom were treated with secondary stent insertions, occlusion with tumor ingrowth and/or overgrowth was observed after the intervention. The median period of primary stent patency in our study was 240 days. Conclusion: Placement of an uncovered Wallstent is clinically effective in patients with malignant gastroduodenal obstruction. Stent placement is associated with high technical success, good palliation effect, and high durability of stent function.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Carotid Artery Stenting Using a Novel Self-Expanding Braided Nickel-Titanium Stent: Feasibility and Safety Porcine Trial

We studied the deliverability and safety of a braided, self-expanding, closed-cell nickel-titanium (NiTi) stent (E-volution, Jotec GmbH, Hechingen, Germany) especially designed for the endovascular treatment of carotid artery bifurcation stenosis with special regard to in-stent stenosis and thrombosis compared with a laser-cut reference nitinol stent in a porcine model of percutaneous vascular interventions. We aimed to assess histopathologic response in minipig carotid and subclavian arteries. Eight minipigs received a total of 42 stents: 14 reference stents and 28 E-volution stents. Eleven of the E-volution stents were additionally coated with heparin. Control angiography was obtained immediately before and after vascular intervention as well as 4 weeks after the procedure. Primary endpoints were 28 days of angiographic analyses as well as histomorphometric analysis, including injury score, inflammation score, luminal diameter, vessel diameter, maximal neointimal thickness, and area of in-stent stenosis. Secondary end points were procedural success, 28-day mortality, and stent thrombosis. All stents could be delivered successfully without procedural complications, morbidity, or mortality during our observation time. As confirmed by histology, no in-stent thrombosis was observed. Compared with common carotid arteries, subclavian arteries are significantly more vulnerable to developing in-stent stenosis caused by neointima proliferation (p < 0.05). Compared with the use of 1 single stent/artery, serial application of two stents leads to a more excessive but not significantly different neointimal proliferation (p > 0.05). The E-volution stent, especially when heparin coated, is in line with the comparison to the laser-cut reference stent displaying similar results of angiographic, histologic, and histomorphometric analyses (p > 0.05). Compared with the reference laser-cut stent, the self-expanding nitinol stent (E-volution) with its advanced braiding technology is feasible and safe. In our opinion, the high radial resistive force and the advanced braided design with tight stent-strut interstices may be beneficial in terms of plaque stabilization. Further studies are necessary and warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5-6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into 'normal-sized' (stent-to-artery-ratio < 1.4, n = 12) and 'oversized' (stent-to-artery-ratio {>=} 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prevention of Intracranial In-stent Restenoses: Predilatation with a Drug Eluting Balloon, Followed by the Deployment of a Self-Expanding Stent

Stenting in intracranial atherosclerotic disease (ICAD) is increasingly debated, due to issues of procedural safety, technical efficacy, and in-stent recurrent stenoses (ISR). In the present study, feasibility, safety, and efficacy of angioplasty using a drug-eluting balloon (DEB) followed by the implantation of a self-expanding stent (Enterprise) were evaluated for the treatment of ICAD lesions. Fifty-two patients (median age: 71 years; range: 54-86 years; male/female ratio 37:15) underwent stenting of high-grade ICAD lesions between February 2010 and November 2011 in a single center. Angioplasty using a paclitaxel coated SeQuent Please (B. Braun, Germany) or DIOR (Eurocor, Germany) coronary PTCA balloon, followed by the implantation of a self-expanding stent (Enterprise, Codman, USA) was performed in 54 lesions. Angiographic and clinical follow-up was performed at 6 and 12 weeks, 6 and 12 months, and yearly thereafter. Technical success rate, periprocedural complications, occurrence of recurrent ischemic symptoms, and the development of an ISR were analyzed. Angioplasty using a DEB followed by stent implantation was successfully performed in 44 (81 %) cases. DEB insertion failed in 19 % of the cases and angioplasty was finally performed using a conventional PTCA balloon. The combined procedure related permanent neurologic morbidity and mortality rate (stroke, ICH, and subarachnoid hemorrhage) at 30 days and beyond was 5 %. Angiographic and clinical follow-up were obtained in 33 (61 %) lesions in 32 patients. Recurrent stenosis was seen in one (3 %) lesion. Angioplasty and stenting using a DEB is safe and yields encouragingly low ISR rates. Further technical developments to improve lesion accessibility are, nevertheless, mandatory.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Efficacy of a Self-expanding Tract Sealant Device in the Reduction of Pneumothorax and Chest Tube Placement Rates After Percutaneous Lung Biopsy: A Matched Controlled Study Using Propensity Score Analysis

PurposeTo evaluate the use of a self-expanding tract sealant device (BioSentry™) on the rates of pneumothorax and chest tube insertion after percutaneous lung biopsy.Materials and MethodsIn this retrospective study, we compared 318 patients who received BioSentry™ during percutaneous lung biopsy (treated group) with 1956 patients who did not (control group). Patient-, lesion-, and procedure-specific variables, and pneumothorax and chest tube insertion rates were recorded. To adjust for potential selection bias, patients in the treated group were matched 1:1 to patients in the control group using propensity score matching based on the above-mentioned variables. Patients were considered a match if the absolute difference in their propensity scores was ≤equal to 0.02.ResultsBefore matching, the pneumothorax and chest tube rates were 24.5 and 13.1% in the control group, and 21.1 and 8.5% in the treated group, respectively. Using propensity scores, a match was found for 317 patients in the treatment group. Chi-square contingency matched pair analysis showed the treated group had significantly lower pneumothorax (20.8 vs. 32.8%; p = 0.001) and chest tube (8.2 vs. 20.8%; p < 0.0001) rates compared to the control group. Sub-analysis including only faculty who had >30 cases of both treatment and control cases demonstrated similar findings: the treated group had significantly lower pneumothorax (17.6 vs. 30.2%; p = 0.002) and chest tube (7.2 vs. 18%; p = 0.001) rates.ConclusionsThe self-expanding tract sealant device significantly reduced the pneumothorax rate, and more importantly, the chest tube placement rate after percutaneous lung biopsy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗